Application for Amend to License DPR-34,ensuring Capability of Primary RCS Components to Maintain Primary Reactor Coolant Envelope as Fission Product Barrier
ML20085J677
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 09/28/1983
From: Lee O
PUBLIC SERVICE CO. OF COLORADO
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20085J678 List:
References
P-83321, NUDOCS 8310130281
Download: ML20085J677 (4)


Text

.- .-

, 7 lf

~

o e '* . ~g y\

s r

PUBLIC SERVICE COiviPAN r vi ovovRADO P. O. BOX 840 . DENVER, COLORADO 80201 OSCAR R. LEE September 28, 1983 v cc . rs'or" Fort St. Vrain Unit No. 1 P-83321 1%3@b l  !

Mr. John T. Collins, Regional Administrator DCT 3W- ,

Region IV l Nuclear Regulatory Ccmmission U; 611 Ryan Plaza Drive Suite 1000 Ix>

Arlington, TX 76011 Docket No. 50-267

SUBJECT:

Proposed Revisions to Fort St. Vrain Technical Specification SR 5.2.6

REFERENCE:

PSC Letter, Warembourg to Kuzmycz, dated 9-27-82 (P-82419)

Dear Mr. Collins:

This letter is to propose a revision to the Fort St. Vrain Technical Specification, SR 5.2.6. This revision is requested based on the following:

l

1) The I-131 and Sr-90 plate-out activities observed on the probe that was removed during the second refueling s were approximately two orders of magnitude lower than LCO 4.2.8 limits. (See referenced letter.)

l l 2) There has been no significant increase in the primary l coolant circulating activity during Cycle 3 operation; hence, there is no reason to expect an increase in plate-out activity.

3) Shifting the plate-out probe evaluation schedule as l proposed will likely increase the significance of the
next evaluation due to the extended residence time in the reactor vessel during Cycle 4.

l The revision proposed in this submittal is provided in Attachment 1, and the evaluation of the significant hazards considerations involved is pravided in Attachment 2.

8310130281 830928 k@ u (

I PDR ADOCK 05000267 PDR

p
i T

. 4 1

, In accordance with the provisions of 10 CFR 170, we believe that the proposed revision is Fee Class III since it involves a single safety issue and does not involve a significant hazards consideration.

A check in the amount of $4000.00 is enclosed for fee payment.

If you have any questions, please contact Mr. Don Warembourg at (303) i 785-2224.

Very truly yours, N

0. R. Lee Vice President Electric Production -

Attachments cc: Albert J. Hazle, Colorado Department of Health ORL/djm i

4


,r--vv- , . - , w c , . . w_--- ,,--.-1

e STATE OF COLORADO )

) ss.

CITY AND COUNTY OF DENVER)

0. R. Lee, being first duly sworn, deposes and says; That he is Vice President of Electric Production of Public Service Company of Colorado, the Licensee herein; that he has read the foregoing Application for Amendment to Appendix A of Facility Operating License and knows the contents thereof, and that the statements and matters set forth therein are true and correct to the best of his knowledge, information and belief.

(( l

0. R.' Lee I Subscribed and sworntobeforemethis28NdayofSeptember,1983.

Witness my hand and official seal.

My commission expires: //-f9-83 .

fk/Abluf f b isw,2n i Notary Pyblic

l

l

- - s  ;

4

)

BEFORE THE l

UNITED STATES NUCLEAR REGULATORY COMMISSION 1

In the Matter of the Facility Operating License)

)

of ) Docket No. 50-267

)

PUBLIC SERVICE COMPANY OF COLORADO )

Application for Amendment to Appendix A of Facility Operating License License N6. CPR-34 0F THE PUBLIC SERVICE COMPANY OF COLORADO FOR THE FORT ST. VRAIN NUCLEAR GENERATING STATION This application for Amendment to Appendix A of Facility Operating License, License No. DPR-34, is submitted for NRC review and approval.

Respectfully submitted, PUBLIC SERVICE COMPANY OF COLORADO By U

0. R~. Lee, Vice President KELLY, STANSFIELD & 0'DONNELL Bryant O'Donnell Robert E. Thompson Public Service Company Building Denver, Colorado 80202 Attorneys for Applicant