OPERATING DATA REPORT DOCKET NO. 050-0325 h DATE 04/01/81 COMPLETED BY EULIS WILLIS TELEPHONE 919-457-9521 OPERATING STATUS

1. UNIT NAME: BRUNSWICK UNIT 1 i 50TE5 ~ ~ ~ ~ ~ ~ ~ ~ ~ - ~ ~ ~ i
2. REPORTING PERIOD: MARCH 81 I I
3. ~ LICENSED THERMAL POWER (MWT): 2436 I I
4. NAMEPLATE RATING (GROSS MWE): 867.0 I I
5. DESIGN ELECTRICAL RATING (NET MWE): 821.0 I I
6. MAX DEPENDABLE CAPACITY (GROSS MWE): 815.0 I I
7. MAX DEPENDABLE CAPACITY (NET 5'E): 790.0
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED IF ANT (NET 5'E): NONE
10. REASONS FOR RESTRICTION IF AST:

THIS YR TO CUMUL MONTH DATE ATIVE

11. HOURS IN REPORTING PERIOD 744.0 2160.0 35401.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL 693.9 1913.1 25715.2
13. P.EACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1647.1
14. HOURS GENERATOR ON LINE 693.9 1850.8 24232.7
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0

~

16. GROSS THERMAL ENERGY GENERATED (MWH) 1349616.1 3520162.4 49504184.3
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 434690.0 1151275.0 16476869.0
18. NET ELECTRICAL ENERGY GENERATED (MWH) 419843.0 1109608.0 15C57042.0
19. UNIT SERVICE FACTOR 93.3 85.7 68.5
20. UNIT AVAILABILITY FACTOR 93.3 85.7 68.5
21. UNIT CAPACITY FACTOR (USING MDC NET) 71.4 65.02 56.7
22. UNIT CAPACITY FACTOR (USING DER NET) 68.7 62.6 54.6
23. UNIT FORCED OUTAGE RATE 6.7 8.2 17.1
24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):

Maintenance, 81/04/17, 1344 Hours

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UP: 4/9/81
26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION): FORECAST ACHIEVED INITIAL CRITICALITY _____ _____

INITIAL ELECTRICITY _____ _____

COMMERICAL OPERATION _____ _____

1.16 - 9 8104270 3I7

{

il 1

- i i

j' - APPENDIX B i AVERAGE DAILY' POWER LEVEL -

s l DOCKET NO. 050-0325

! UNIT BRUNSWICK UNI 7 1

[

DATE 04/01/91  ;

-COMPLETED BY EULI8 WILLIS '

l l TELEPHONE 919-457-9521 4

MARCH 81 p -

I ' DAY' AVG. DAILY POWER LEVEL DAY AVG. DAILY POWER LEVEL i I

i (MWE-NET) (MWE-NET) i f I .683. 17 -395.

r 2 6V2. - 18 594.-

l 3 703. 19 546.

~4- 704. 20 546.  ;

]  ;

j 5 l' 521. 21 405.

j ,

!. 6- .

365. 22 564.

f 7 580. 23 685. I 8 507. 24 641.

9 653. 25 579.

j' 10  ! 593. 26 709. 3

11 682. 2/ /10. r t

12 671. 28 689.

13 '

t 663. 29 643.

14 673. 30 -13.

15 674 31 -13.

16 460.

I i

1.16 - 8 Ilit194419f f f B f f 28 3 9 # 3iIIIE 5 t #IfI 8fIf f f a t f f a $ t fIf 93 9f 3 9 It il f 3 54 ilsfIi 4 9 9 tIf 3 3 3 9 33 9If fit j f 3 3 3i f 31if f f 3 3 3Ii 3 5 tf f 3iI 93 sl POR ORIGINAL

O h O '

UNIT SilUIDOWNS AND POWER REDUCTIONS DOCKET NO. nsn_nus ,

UNIT NAME R ru n cu f e t- m i DATE Anril 19R1 _ _

COMPLETED BY Frnnrou st' 'r.ison REPORT MON 111 March 1981 TELEPHONE as7-os*i j - E E

, Ig 3 y .'E 5 Licensee ,Ew, geo Cause & Corrective No. Date i 3= $ .2 s 5 Event g3 gO 3 Action to H $ :,, 5 j ;f3 g Report # un U g Prevent Recurrence 6

j 009 81 0305 F 28.3 A 1 NA GENERA While reducing recirculating pump

, speed to remove MG set for brush j replacement, failure of the brush

. rigger occurred causing damage to .

j brush rigger holder.

The MG set collector rings was 4 .

machined. MG set brush rigger and

- holder was repaired and reinstalled.'

. I 2 3 4

! F: Forced Reason: Method: Exhibit G Instructions S: Scheduled A l'quipment Failure (Explain) l-Manual for Preparation of Data

) Eniey Sheets for Licensee

! B-minienance of Test 2 Manual Scram.

C. Refueling 3 Automatic Scram. Event Report (LER) Fde (NUREG.

D Regulatory Restrictiun 44her (Explain) 0161) i E-Operator Training 1 Ucense Examination F Administrative 5

) G-Operational Error (Explain) Exhibit I Same Source 19/77) Il-Other (Explain) l

h O UNIT SilUTDOWNS AND POWER REDUCTIONS DOCKETNO. 050-0325 ,

UNIT N AME Brunswick No. I DATE April 1981

! COAIPLETED BY Frnncon Ilnrr knn a

REPGRT MONTH Harch 1981 TELEPilONE 197-os?i i

  • f i

i

-, .$E 'hg Y Licensee E

% !8% Cause & Corrective No. Date g 3g ,g g 5 Event tt Y 3 Action to l

i

$E 5 j5g Repor

  • E0 ju Prevent Recurrence 1 6 1 .

010 81 *0307 F 21.2 A 1 NA IIC llTEXCll 1A north waterbox had bad tube leak, i

Replug tubes that were leaking.

1 l .

1 i

i i

1 i

l t

i

! I 2 3 4 i

F: Forced Reason: Method: Exhibit G Instructions

S
Scheduled A lip.:pment Failure (Explain) I-Manual for Preparation of Daia
U minienance aiTest 2 Manual Scram. Er*ry Sheets for Lie
nsee

! C Refueling 3 Automatic Scram. Event ReporI (LE RI Fde INUREG.

D-Regulatory Restriction 4 Other(Explain) 0161)

E-Operator Training & Ucense Examination F Administrative 5 G Operational Error (Explain) Eshibit I Same Sour;c 19/77) Il-Other (E xplain)

e C *

~ C V e C

k g

2: L

, W C V,o

.:c cc m

d t-e -3 o

U 3

D z

e e m V c, U >

  • y et 3 T. V u kJ o c t cr o G $ * -e *u CA~~

b i ' c:n ~ c i = mu =q8a 2 C ,c"u e o 3 s e u. s e o e .C s,tW Q-s N Cim 4 4 e w w Q c. W

<C .c u C o . w o - - .a g w w .cd-

-d.2 3= -

W c 4 c"W 7 W* >m Z m

-43 2

s 2*

ou o

mm oo

~2.5 z c. m.

>Z< c< W" 7 o G % os zu > 0.u 4u -

w H 3 4"2 --

m o o3 -mm -

aH - W w g<c

- =c wa s=

ow 32xc-

= c. -

2=

z a, aa w a o

> a- - u- n- e ,v e -

D

.e.H Q

-e w g u e aJ wcwwo- w i o w= cs w '

V o ?! 30 y e '

aw :c m a M N O C eo a=

ou u

Q .a.e . ;n *

-> % -J o= cc C/3 J 2*. C m

Z e O

C s . n~

d U w 53P03 w .EO$

m-a-

e e

tuauodtuo3 z C

2 mg g ,3 U M . . q ; @ *-. -

M 2335

- C- ,3 g a W u e P390) m 533<3-u4e 0 g f. tuaisiS v 2.!- A M a.

C C z

A Z

. M m O u u z 2 3g-3: H C o

.-d ?a .o o-E C C

O a m <

H W z -

D

  • E

=

3 R

-J418.*CJM tlWM y $urtinys

^

g 7

.lo PtytoW c. 5 v

1

- m .

l w 53 W n

w t

.thl5EJM uO -M

"; w

' < E 29 3

-a, .H m 33 o C u ,M 'C'-

t u- =;a s

(unol{} c if OH -

=.;s; -=22S as9 5m m -

ungem0 - ==-

" .: E: 252E23 1 3 C 10 9 C ft 4 5= 1 C. 3 - - = =

-s L, M =o *ac%o<OO l l3dk -

. E d dCC-dio-l es l

m O

u m z o l

C w J

x .

,f vsJ o Ie C,.

Ce

  • e Z

4 . 6m c P%.

w  :;-

O -

l I

l l

b i

DOCKEINO. 050-0325 ,

UNIT SliUTDOWNS AND POWER REDUC 110NS -Brunswick No. 1 UNIT NAM E DATE- April ingi COMPLETED BY Pr an~ c um vicon REPORT MONTil March 1981 TELEPHONE 457-9521 i

1 w

Q0 _

a l  :, E_E 3 j Ei Licensee Evo ., Cause & Curreceive l*3 No. Date & 38 $ 2s5 Event (3 gO Action to

  • $ ,, 5 j I?3 g Report # va O g Prevent Recurrence d

i .

012 81 0316 F 10.5 A 1 NA IIC llTEXCil 1A south waterbox had tube leaks.

1 Replugged tubes that were leaking.

1 .

i 1

4 i .

I i

i 4

I 2 3 4 Exlubit G Instruesions 5

F: Forced Reason: Method:

S: Scheduled A nluipment Failure (Explain) 1 Manual for Preparation of Data l' Entry Sheets for Licensec It Maintenance of Test 2. Manual Scram.

C. Refueling 3 Automatic Scram. Event Report (LER) Fde INUREG.

. D Regulatory Restriction 4 Other (Explain) 0161)

E Operator Training & Ucense Examination

), F Administrative 5 G-Operational Error (Explain) Exhibis I .Same Source l

j 19/77) Il Other (Explain)

I

'D D 050-0325 1

DOCKET NO. .

UNIT SilUTDOWNS AND POWER REDUCTIONS B rim <:u l c k Nn. 1 UNIT NAME DALE April i oni COMPLETED BY Frnnres Harrison REPORT MONTil March 1981 457-9s?1 TELEPif0NE t

- E E

.$g 3 $D Licensee ,E g je. Cause & Correceive 5= 2s5 g3 Action so No. Date i i Event g~3 l

W d i:, 5 j;5g Repori# mu g* Prevent Recurrence i c5 i

013 81 0317 F 5.7 A 1 NA CA INSTRU The actuation screw for 1-B21-PS-N021D was out of adjustment causing the pressure switch to be out of calibra-tion.

l Switch actuation linkage was adjusted to provide normal operating band and switch was calibrated, declared operable, and returned to service.

1 I 2 3 4 F: Forced Reason: Method: f xhibit G . Instructions S: Scheduled A.I'quipment Failure (Explain) 1 Manual for Preparation of Data B Maintenance or Test 2 Manual Seram. Entry Sheets for Licensee C Refueling 3 Automatic Scrain. Event Report (LERI File (NUREG.

D Regulatory Restriction 4-Other (Explain) 0161)

E-Operator Training & License Examination F. Administrative 5 G-Operational Error (Explain) Eshibit 1.Same Source "

19/77) Il-Other (Explain)

b b b DOCKET NO. 050-0325 ,

UNIT SliUTDOWNS AND POWER REDUCTIONS Brunswick UNIT NAME DATE April 1981 COMPLETED BY F. IIn rri son REPORT MONT11 }1ARCil 1981 1ELEPHONE 457-9521 e.

, $3 3 Y Eicensee ,E **,, o k"y Cause & Corrective Action to No. Date i 5g i .s s 5 Event  ??

nb U 8-

$E E j;gg Repott# Prevent Recurrence d

014 81Q320 F 30.8 A 1 N/A IIC llTEXCil Tubes leaking in A-South condenser waterbox.

llelium leak cliecked and plugged in tubes in A-South waterbox. .

l I

i l t 2 3 4 F: ForccJ Reason: Method: Exhibit G - Instructions S: Scheduled A Equipment Failure (Explain) 1-Manual for Preparation of Data li Maintenance of Test 2-Manual Scram. Entry Sheets for Licensee d

C Refueling 3 Autunutic Scram. Event ReporI(LERI File (NURLC.

D Regulatory Restriction 4-Other (Explain) 0161)

E-Operator Training & License Examination F Administrailse 5 G. Operational Error (Explain) Exhibit I Same Source 08/77) Il-Other (Explain)

(

e C .

- O -

r a i - =
  • s t e

" .L .

"

  • S

=

C m N -

L 7 A T Z

- :n N c%

%Z g :

- g

" 3 Z

M 3 o c a -

C  : - c e g -

0-Dv i e - c e  % y

  • ss?

x--6 3 C  : u C N e n e u e ~[

r 3- aM3a mx 3

=

c c < 4 4 o

.c W

su -

- e sY w W

- C :n U y

C O u 5 *13d 2 % *'

I C*WW>W Ug 4 b o [ .*.*. 5*

O T ,J *$,

7<-o Z < P= CIR z

.- s

= =v o' 4" / uns&

  • -n 9 bz:G:

2 % HI 022 4~.

t u

i. 5- d =e-xg~ ,& Oi z .=

- W g<=u o= - o> d gz a .a =u n u u a-cauc>-oe a

xD sg y s

C au e

- u o 3 - :n wcwwo w a

.r.

o " k o E v u .= z .= o w w mu ec : u ea u . u :c C-u .J C u o auu u-z oz

- o c. u -

ooc = oo x v :z: E. u u M .

Z =

0 < .c f 5 S*903 5 55.y" g guacoduro3 g g

[

n O .. M - $ w='

mS .y g t 72 5 -ee-3 53 5 5 p*P03 R

  • b $ 5 k.= 6 3: tuatsig 2 - F. A r o

a.

C m z

==

z

. M m o

- a w .

o Z e

-Er o 3 W .C o e. --o >. c.

d .o < c w a x z o

.O a. =n 3 w =

M -

?

m a W

d iJOI.' u d ILW Q W Z Su!!!nys m e

D n

3

=

g JoPoyl3N .2 c,. 3 c.

m 53

-uosny <

uC 4 .=a

.~! ., r 6

se == :_

.=,

.a u C U .*i =

u; x :; .c .2

  1. a ; 7 c.

(smogg) . -c = =e e . a2- .2 : - ;; : w uottema o =~

. . =. ai .7 z, 'a: s -

u =

C =, . = % = y~M

7. y*4 u9 ra vC.
  • =3*.=

7- ;. = = q "< q o x < d G = w ti o=

adii 'e-ce

      • a N S M C C s w

5]

& ~3

  • J y N

- ..C, C, .

c N e P.

-)* o . wm q

?

O g - - ~ - -

e- --- e-- - m.- , - - .r-, ,, - .- -- - - - . - - - - - - - , , - , - - - -

APPENDIX DOCKET NO: 050-325 UNIT: Brunswick No. 1 DATE: April 1981 COMPLETED BY: Frances Harrison OPERATIONS SLT'ARY BRUNSWICK UNIT NO. 1 Brunswick Unit No.1 operated at a 93.3% availability factor for the month of March with a 71.4% capacity factor. There were six power reductions this month, and one "off-line" outage, both are detailed in Appendix D, the unit shutdowns and power reductions log.

There are 476 BWR and 160 PWR spent fuel bundles in the Brunswick Unit No. 1 fuel pool.

e #

. . e . .

yYwp..

b 4p7 Q m ;q . ,. p s.,...

. . ..e .j -

sp . .,s,-

. .. . -,  %- w. .

r v .m. e

    • j

.p.te. .=. g , g l.l s 9. *. L.9

  • V.5.,m.d." .

I.g gJ.

. =t . _ .se.'M. g1 p!+g....... . . = . -lg., f I. 6 .-

4 M& F.

  1. ' on
  • A
  • )% e T#LQ .*, / .%

=

=. $ e.6h O.h.$,..f.*.

p m. g.n o m..

W

.a s m .- e

  • M.i.T..'

e 8.k$.

.U .

g e6

, - amo

.- .y.%. fsa 9 gu.p. . . .

q ,g. W e g *g..ge ..# .

  • y eeu. Me s .

, M. e*.I

. e gw.

W.A

  • a

,.,. ye p g .

go .e yg. e

.-1. w .*. , -- j _-

m99m e.

i ,qgp e gg, u v .4 J.

m g

. 3 1= g.ppgme m9ye,

,_..j, 4 .

2.,A  %.

.$'P-W - g 1

6 . d .Sm.. 6a % .m II 6 e .

.t-/

g .- e.

4. A a -. o .

e =- g A or

-A. ,.=f4 ., . -f *

. esue . 44>

.,.e'

,.y",..S' e . Y. f e s . .. .g .

M . 4 e. e e'.--> . e

.g

= g .l.

, ." .- e6 em . . e h O

? * *tM "

a5 e".,

e.

%., g f 9 e. e. . S n

  • f
  • e.f *, 8

..f

  • N. @

m ge .t a sump

% *. .% I h'

. ee

  • D. O r

, m e .a " e

.e.

.. J

  • **= -, e

} m #q e a.Tb.. M*.'S q q 4 .

y e .J7e

..yg

4. s e am a

1b

  • O . Ao e .

J e 'd m

'.# E

. ., , . +

eb

. -g> g .a,q:. e .,

a. . s.

e p' %g .

ea 4g WP N. S .d.y * %. .

8 g- a m.

w J

e s a

  • f. e e -.

.+.a

  • S O

4 9 .5 P00RBRWNAL

OPERATING DATA REFORT DOCKET NO. 050-0324 DATE.04/08/81 COMPLETED BY EULIS WILLIS TELEPHONE 919-457-9521 OPERATING STATUS

1. UNIT NAME: BRUNSWICK UNIT 2 I NOTES I
2. RE?ORTING PERIOD: MARCH 81 I I.
3. LICENSED THERMAL POWER (MWT): 2436 I I J.~NAME? LATE RATING (GROSS MWE): 867.0 I I
5. DESIGN ELECTRICAL RATING (NET MWE): 821.0 I I
6. MAX DEPENDABLE CAFACITY (GROSS MWE): 915.0 I I.
7. MAX DE?ENDABLE CAPACITY (NET MWE): 790.0- -------------------------------
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST RE? ORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE): NONE
10. REASONS FOR RESTRICTION IF ANY:

THIS YR TO CUMUL MONTH DATE ATIVE

11. HOURS IN REFORTING PERIOD 744.0 2160.0 27425.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL 101.9 1257.4- 30279.7
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 0.0

.14 HOURS GENERATOR ON LINE 101.9 1176.7 28140.9

15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 178109.2 1944271.0 51555651.8
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 60459.0 -670824.0 17235270.0
18. NET ELECTRICIAL ENERGY GENERATED (MWH) 53081.0 640099.0 16545508.0
19. UNIT SERVICE FACTOR 13.7 54.5 59.3
20. UNIT AVAILABILITY FACTOR 13.7 54.5 59.3
21. UNIT CAPACITY FACTOR (USING MDC NET) 9.0 37.5 44.2
22. UNIT CAPACITY FACTOR (USING DER NET) 8.7 36.1 42.5
23. UNIT FORCED OUTAGE RATE 86.3 40.3 13.9
24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE,-DATE, AND DURATION OF EACH):
25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UF: J/ 9 /81
26. UNITS IN TEST STATUS (PRIOR TO COMMERICIAL OPERATION): FORCAST ACHEIVED INITIAL CRITICALITY -------- --------

INITIAL ELECTRICITY -------- --------

COMMERICIAL OPERATION -------- --------

1.16 - 9

O h O i

DOCKET NO. 050-0324 .

UNIT SilUTDOWNS AND POWER REDUCTIONS UNIT NAME Brunswick No. 2 DATE April 1981

} COMPLETED BY Frances llarr1 son REPORT MONTil March L98i TELEPHONE 457-9521 r

":. /

I E "E Eb Licensee Ee  !% Cause & Corrective No. Date -h j$ $ 3j$ Event

{i hu Action to H

f5 5 j;gg Report # mO g Prevent Recurrence 6

010 810'105 F 642.1 A 2 NA Sil SUPORT The unit was separated from the grid for a snubber outage.

The outage will be detailed in a report submitted for the month the, unit returns to service.

e I 2 3 4 l F: Forced Reason: Method: Exhibit G -Instructions S: Scheduled A li mpment i Failure (Explain) 1 Manual for Preparation of Data B-mintenance of Test 2 Manual Scram. Entry Sheets for Licensee C.Hefueling 3. Automatic Scram. Event Reporn (LER) Fde (NUREG.

D Regulatory Restriction 4-Other (Explain) 0161)

E Operator Training & License Examination l F Administrative 5

! G Operational Error (Explain) Exhibis 1.Same Source l

19/77) II Other (Explain) l _ -

APPENDIX DOCKET NO: 050-324 UNIT: Brunswick No. 2 DATE: April 1981 COMPLETED BY: Frances Harrison OPERATIONS

SUMMARY

BRUNSWICK UNIT NO. 2 Brunswick Unit No. 2 operated at a 13.7% availability factor for the month of March with a 9.1% capacity factor. There was one "off-line" outage, it - is detailed in Appendix D, the unit shutdowns and power reductions log.

4 There are 264 BWR and 144 PWR spent fuel bundles in the Brunswick No. 2 fuel pool.

i l

l l

l e

f l

. ..~,. -, - , . , . - , - - . - . -.

,.n....- -