LER 79-025/03L-0 on 790228:power Range Channel N42 Placed in Tripped Condition.Caused to Allow Replacement of Erratic Delta Flux Indicator.Indicator Replaced & Power Range Detector Returned to Svc
ML19270F830
Person / Time
Site: North Anna Dominion icon.png
Issue date: 03/21/1979
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19270F823 List:
References
LER-79-025-03L, LER-79-25-3L, NUDOCS 7903270584
Download: ML19270F830 (2)


Text

(7 77)

. . LICENSEE EVENT REPORT h CONTROL DLOCK: l l l l l l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

O i lV A fl l A l S 1 lgl 0 l 0 -

0 0 0 l0 l0 J- 0 0h lgl4 [1 l1 (1 l1 lgl l lg i 8 3 LICENSE E CODE 14 :s ticENSE NUM9EH 26 UCENSE TYPE JO 51 C AT E,8 COTT fi "7 ls I L lgl 0 j 5 l 0 l 0 l 0 3l3l8lgl0 2j2]8l7l9lglgj/3 3 l ,, ] 3 l , j q [g 68 69 EVENT D ATE 14 REPORT DATE 80 b t4 61 DOCKET NUYBEH EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h n 2 l During normal mode 1 operation, power range channel N42 was placed in tripped condi-  ;

o 3 i tion to allow replacement of the N-42 Delta Flux indicator. Action Statement 2c of  ;

i o g ; ; T.S. 3.3.1.1 was entered and the quadrant power tilt ratio was monitored. The health ;

o ,,  ; and safety of the general public was not endangered. This event is reportable per  ;

o o T.S. 6.9.1.9.b.  ;

O 7 i O H  !

l 80 7 8 9 SYSTENt CAUSE CAUSE COMP. VALVE CODE CODE SUBCODE COYPONENT CODE SU8 CODE SUBCODE 1

O 9 8

l I] D l@ W@ l E l@ [I lN lS lT lR lU l@ l Il@ W @

9 10 11 12 13 18 19 20 SEQUEN TI AL OCCURRENCE REPORT REVISION EVENT YE AH REPOR T NO. CODE TYPE N O.

@ RErygRr LE R RO l7 9 l_l 0 l 2l 5 l/] l 0l 3l 73 M y

30 l_

31

[0J 32

_ 21 22 23 24 26 21 AKEr AC T ON ONPL NT T HOURS 22 S 8 IT FOR b 9. SUPPLt MAN FACTURER l33A lgl34Z l g lSZjg lZ @ l0 l0 l0 lU 40l lY l@

41 l42 Yl@ Nl@ lWl1l2l0l@

44 3 36 3/ 43 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h i O l Power range channel N-42 was placed in the tripoed condition to allow replacement of I

, i ;an erratically reading Delta Flux indicator. The indicator was replaced without I

,, ,,,  ; complications and power range detector N-42 was returned to service. l 1 3 I i 4 I I

7 8 9 80 ST S .POAER OT H E R ST ATUS iSCO HY DISCOVERY DESCRIPTION li 151 LLl@ 11 lo lo 181 N/A I LZ_J@l N/A l AC TIVI T Y CO TENT HELEASED OF RELE ASE AY0uNT OF ACTIVITY LOCATION OF RELEASE l i l 6 ] [z_J @ (Zj@l N/A l l 45 N/A 80 l

t 8 9 10 11 44 PEHSONNEL E xPOSURES NUURER TYPE C E S TL pTION i 7 1010 Oj@l z @l N/A l

,ERSONNJ',NJ2.ES NunE n Dts:n4riO 8 li I, I I 0101 O l@l N/A l 8 9 12 80 79032705/[/

1 11

'$1 ' "fSCT^A'Or^c'u r- @

T l l 9 l [zj@l

~

N/A _a l a 9 80 3454MJC ~ p-

, io - -

NRC USE ONLY

, f"""r Ltd@g'llcn,,,,os @

2 o l N/A I 08 69 IIIIIIiiil Il5 80 5 1 8 9 10 N A\iE OF PHEPARE R W. R. Cartwright pnoye. 703-894-5151

Attachment 1, page 1 of 1 Virginia Electric and Power Company North Anna Power Station, Unit #1 Docket No.: 50-338 Report No.: LER 79-025/03L-0 Description of Event:

During normal n ade 1 operation, channel N-42 delta flux indicator was noticed to be reading erratically. The other channels did not e xh ib i t the same behavior as channel N-42, therefore faulty indication was suspected. Although the indicator was still within calibration tolerances, replacement was desired. Power range channel N-42 was placed in a tripped condition and channel N-42 delta flux indicator was replaced within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Probable Consequences of Event:

The delta flux indication associated with the power range detectors gives a continuous indication of flux shape within the core. Opera t ional requirements limit delta flux to certain values to insure hot channel factors are not exceeded. Although there is no reactor trip associated with the delta flux indication, it is still a safety related indication.

There are other methods for determining in core flux shapes in addition to three other delta flux indicator channels. Disabling one channel of power range instrumentation did not affect the safe operation of the plant or the health and safety of the general public.

Cause of Occurrence:

The cause of the erratic indication of channel N-42 delta flux indication was due to indicator failure.

Immediate Corrective Actions:

Channel N-42 delta flux indicator was replaced.

Subsequent Corrective Action:

No further action required.

Action Taken to Prevent Recurrences:

No further action required.

,