Letter Sequence Acceptance Review |
---|
|
|
MONTHYEARML19276D3982019-10-0303 October 2019 Exemption Request to Load and Store Spent Fuel in HI-STORM FW Spent Fuel Casks Utilizing Amendment 1, Revision 1 to CoC No. 1032 Project stage: Other ML20115E3782019-10-0303 October 2019 Independent Spent Fuel Storage Installation Exemption Safety Evaluation Report Project stage: Approval ML20014E6772020-01-0909 January 2020 Fws List of Threatened and Endangered Species That May Occur with Respect to the McGuire Exemption Request Project stage: Other ML20015A3142020-01-14014 January 2020 Package: Exemption Request McGuire Nuclear Facility Project stage: Request ML20049A0812020-01-31031 January 2020 Holtec International - HI-STORM 100 Storage CoC Renewal Application Project stage: Request ML20055F3372020-02-20020 February 2020 Conversation Record - Clarification Call (02/20/2020) on RAI 1 for CoC 1040 Umax Amendment 4 Project stage: RAI ML20064F6162020-02-29029 February 2020 January 15, 2020, Summary of Meeting with Holtec International, Inc., to Discuss the Upcoming Submittal of the Application for Renewal of the Storage Certificate of Compliance No. 1014 for the HI-Storm 100 Cask System Project stage: Meeting ML20064E6222020-03-0303 March 2020 U.S. Nuclear Regulatory Commission Approval of NAC International Request for Withholding Information from Public Disclosure for Coc 1025 Renewal (CAC No. 001028) Project stage: Withholding Request Acceptance ML20063M0152020-03-0303 March 2020 HI-STORM 100 Renewal Presubmittal Meeting (Holtec Slides, 1-15-20) Project stage: Meeting ML20071F1532020-03-0505 March 2020 Interim Storage Partners, LLC - Supplemental Information in Support of Nrc'S Environmental Review Project stage: Supplement ML20071F1562020-03-0505 March 2020 Interim Storage Partners, LLC - Affidavit Project stage: Other ML20071J0552020-03-0505 March 2020 Notice of Cancelled Meeting with the U.S. Department of Energy, Idaho Operations Office to Discuss the Upcoming Submittal of the Application for Renewal of the Idaho Spent Fuel Facility License (SNM-2512) Project stage: Meeting ML20065K2162020-03-0505 March 2020 Notice of Meeting with U.S. Department of Energy, Idaho Operations Office to Discuss the Upcoming Submittal of the Application for Renewal of the Idaho Spent Fuel Facility License (SNM-2512) Project stage: Meeting ML20065L3442020-03-0606 March 2020 Amendment No. 15 to Certificate of Compliance No. 1014 for the Hi-Storm 100 Multipurpose Canister Storage System - Request for Additional Information Project stage: RAI ML20066K5782020-03-0606 March 2020 Acceptance Review of Request for Amendment No. 7 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Acceptance Review ML20065N2812020-03-0909 March 2020 ISFSI Preamble-License Renewal Order Project stage: Other ML20065N2772020-03-0909 March 2020 ISFSI Renewal Cover Letter Project stage: Other ML20065N2852020-03-0909 March 2020 ISFSI Renewed Technical Specifications Project stage: Other ML20076D6962020-03-11011 March 2020 Interim Storage Partners, LLC - Submittal of Clarifications to Support Nrc'S Continued Review of the Safety Case for the WCS CISF Project stage: Other ML20071D9942020-03-11011 March 2020 Submittal of HI-STAR 100 Updated FSAR, Revision 4 Project stage: Request ML20065N2782020-03-11011 March 2020 ISFSI FRN Notice of Issuance for License Renewal Project stage: Other ML20104C0192020-03-30030 March 2020 International - Affidavit for Kimberly Manzione Project stage: Other ML20104C0152020-03-30030 March 2020 International - Amendment No. 4 to the HI-STORM Umax Canister Storage System Project stage: Other ML20104C0162020-03-30030 March 2020 International - Proposed HI-STORM Umax CoC Amendment 4 Appendix a - Changed Pages Project stage: Other ML20104C0202020-03-30030 March 2020 International - HI-STORM Umax Amendment 4 Responses to Requests for Additional Information - Supplemental Information Project stage: Supplement ML20104C0182020-03-30030 March 2020 International - HI-STORM Umax Amendment 4 FSAR - Changed Pages Project stage: Other ML20091L0642020-03-31031 March 2020 Enclosure 1 - Request for Additional Information - Non-Proprietary Project stage: RAI ML20101P3992020-03-31031 March 2020 Interim Storage Partners, LLC - Submittal of Draft Responses for Several Rals and Associated Document Markups from First Request for Additional Information, Parts 1, 2 and Clarifications Project stage: Draft Request ML20065N2802020-03-31031 March 2020 ISFSI License Renewal SER Project stage: Other ML20104C0482020-03-31031 March 2020 International - HI-STORM Umax Amendment 3 Responses to Requests for Additional Information Project stage: Response to RAI ML20105A1352020-03-31031 March 2020 Enclosure 1 - Affidavits Project stage: Other ML20091L0632020-03-31031 March 2020 Transmittal Letter - CoC 1042 Amendment Number 2 Request for Additional Information Project stage: RAI ML20105A1732020-04-0606 April 2020 Interim Storage Partners, LLC - Affidavits Project stage: Other ML20099A1802020-04-0606 April 2020 Application for Renewal of the Certificate of Compliance No. 1014 for the Hi-Storm 100 Storage Cask System Accepted for Review (Cac/Epid Nos. 001028/L-2020-RNW-0007) Project stage: Other ML20105A1722020-04-0707 April 2020 Interim Storage Partners, LLC - Submittal of Supplemental Information in Support of RAI, Part 3 Project stage: Supplement ML20105A1362020-04-0707 April 2020 Enclosure 3 - RAIs and Responses Project stage: Other ML20105A1392020-04-0707 April 2020 Enclosure 8 - Referenced Documents Project stage: Other ML20105A1382020-04-0707 April 2020 Enclosure 7 - SAR Changed Pages Project stage: Other ML20105A1342020-04-0707 April 2020 Submission of ISP Responses for RAIs and Associated Document Markups from First Request for Additional Information, Parts 2, 3, and 4 Project stage: Request ML20105A1372020-04-0707 April 2020 Enclosure 5 - La Changed Pages Project stage: Other ML20100F2952020-04-0909 April 2020 Tn Americas LLC - Submittal of Renewal Application for the TN-68 Dry Storage Cask - CoC 1027 Project stage: Request ML20104A0402020-04-10010 April 2020 Request for Additional Information for HI-STAR 100 CoC Renewal Application Project stage: RAI ML20111A2382020-04-13013 April 2020 International - HI-STORM Umax Amendment 4 Responses to Requests for Additional Information - Supplemental Information Project stage: Supplement ML20111A2402020-04-13013 April 2020 Attachment 2: Proposed HI-STORM Umax CoC Amendment 4 Appendix a - Changed Pages (non-proprietary) Project stage: Other ML20111A2392020-04-13013 April 2020 Attachment 1: HI-STORM Umax Amendment 4 RAI Supplemental Response (non-proprietary) Project stage: Supplement ML20094G4822020-04-15015 April 2020 GEH-Morris QAP Rev 4 Approval Project stage: Other ML20092L1732020-04-17017 April 2020 Safety Evaluation Report for the Pacific Gas and Electric Company Humboldt Bay Independent Spent Fuel Storage Installation Quality Assurance Plan HBI-L6 Revision 0 Project stage: Approval ML20128J2922020-04-27027 April 2020, 28 April 2020 International, Submittal of Responses to Nrc,S 1st Round RAIs for HI-STORM 100 Amendment Number 15 Project stage: Request ML20128J2932020-04-28028 April 2020 International, Submittal of Responses to Nrc,S 1st Round RAIs for HI-STORM 100 Amendment Number 15 Project stage: Request ML20120A2282020-04-29029 April 2020 Tn Americas LLC, Response to the Request for Additional Information to Application for Certificate of Compliance No. 1042, Amendment No. 2, to NUHOMS Eos System, (Docket No. 72-1042, CAC No. 001028 EPID: L-2019-LLA-0078)- Request for Extens Project stage: Request 2020-03-06
[Table View] |
|
---|
Category:Letter
MONTHYEARML24309A2872024-11-0404 November 2024 International, HI-STORM 100 Amendment 19 Responses to Requests for Additional Information AEP-NRC-2024-80, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask2024-10-15015 October 2024 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask ML24274A3032024-10-0909 October 2024 Amendment 19 to Certificate of Compliance 1014 for Hi-Storm 100 Multi-Purpose Canister Storage System Request for Additional Information ML24240A1182024-10-0808 October 2024 0 Issuance Letter Amendment 18 to Renewed Certificate of Compliance No. 1014 for the HI-STORM 100 Cask System SVP-24-059, Correction to Registration of Use of Casks to Store Spent Fuel2024-10-0404 October 2024 Correction to Registration of Use of Casks to Store Spent Fuel AEP-NRC-2024-79, Unit 2, Independent Spent Fuel Storage Installation - Registration of Dry Spent Storage Cask2024-09-26026 September 2024 Unit 2, Independent Spent Fuel Storage Installation - Registration of Dry Spent Storage Cask ML24263A2062024-09-19019 September 2024 Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for LaSalle County Station - Holtec MPC-68MCBS NL-24-0351, – ISFSI - Registration of Spent Fuel Cask Use2024-09-13013 September 2024 – ISFSI - Registration of Spent Fuel Cask Use ML24222A8592024-08-0909 August 2024 International - HI-STORM 100 Multipurpose Canister Storage System Amendment 19 Request ML24221A2702024-08-0808 August 2024 Unit 2 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Storage Cask AEP-NRC-2024-62, Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask2024-08-0707 August 2024 Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask SVP-24-048, Registration of Use of Casks to Store Spent Fuel2024-07-31031 July 2024 Registration of Use of Casks to Store Spent Fuel ML24178A4312024-07-29029 July 2024 Issuance of Certificate of Compliance No. 1014, Amendment No. 16 for the HI-STORM 100 Cask System, Cover Letter AEP-NRC-2024-56, Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask2024-07-0808 July 2024 Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask NL-24-0199, Request for Specific Exemption2024-06-25025 June 2024 Request for Specific Exemption SVP-24-040, Registration of Use of Casks to Store Spent Fuel2024-06-25025 June 2024 Registration of Use of Casks to Store Spent Fuel NL-24-0243, Registration of Spent Fuel Cask Use2024-06-18018 June 2024 Registration of Spent Fuel Cask Use ML24183A2752024-05-30030 May 2024 Registration of Use of Casks to Store Spent Fuel ML24145A0432024-05-23023 May 2024 Registration of Use of Casks to Store Spent Fuel 10 CFR 72.212 SVPLTR 24-0019, Registration of Use of Casks to Store Spent Fuel2024-05-23023 May 2024 Registration of Use of Casks to Store Spent Fuel ML24143A0752024-05-22022 May 2024 Re. Ginna Nuclear Power Plant and Independent Spent Fuel Storage Installation (ISFSI) Registration for Use of General License ISFSI Casks NL-24-0197, Registration of Spent Fuel Cask Use2024-05-20020 May 2024 Registration of Spent Fuel Cask Use ML24135A3212024-05-14014 May 2024 Annual Radioactive Effluent Release Report, January 1 Through December 31, 2023 CP-202400153, (Cpnpp), Registration of Dry Spent Fuel Storage Canisters2024-04-29029 April 2024 (Cpnpp), Registration of Dry Spent Fuel Storage Canisters SVP-24-028, Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report2024-04-26026 April 2024 Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report ML24109A2072024-04-18018 April 2024 International - Submittal of HI-STORM Final Safety Analysis Report Update BYRON 2024-0021, Registration of Use of Cask to Store Spent Fuel2024-04-11011 April 2024 Registration of Use of Cask to Store Spent Fuel BYRON 2024-0019, Registration of Use of Cask to Store Spent Fuel2024-03-28028 March 2024 Registration of Use of Cask to Store Spent Fuel RS-24-020, Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for Quad Cities Nuclear Power Station - Holtec MPC-68MCBS2024-03-15015 March 2024 Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for Quad Cities Nuclear Power Station - Holtec MPC-68MCBS LR-N24-0022, Spent Fuel Cask Registration2024-02-29029 February 2024 Spent Fuel Cask Registration ML24046A2552024-02-15015 February 2024 International, Submittal of Supplement to RAI Responses on HI-STORM 100 Amendment 18 ML24016A1902024-01-30030 January 2024 International, Inc. - Notice of Violation; the U.S. Nuclear Regulatory Commission Inspection Report 07201014/2022201 ML24018A1992024-01-18018 January 2024 International, Administrative Change to HI-2200343-A ML23363A0312024-01-0404 January 2024 Application for HI-STORM 100 Cask System, Amendment No. 19 - Acknowledgement of Withdrawal and Notification of the U.S. Nuclear Regulatory Commission Staff Efforts Closure ML23355A0842023-12-21021 December 2023 International, Withdrawal of HI-STORM I00 Multipurpose Canister Storage System Amendment ML23324A0952023-12-0606 December 2023 Amendment No. 19 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multi-purpose Canister Storage System - Request for Additional Information ML23328A0052023-12-0505 December 2023 Issuance of Renewed Certificate of Compliance No. 1014, Amendment No. 17 for the Hi-Storm 100 Cask System (Cac/Epid 001028/L-2021-LLA-0140) ML23338A3052023-12-0404 December 2023 International, Submittal of Supplement to RAI Responses on HI-STORM 100 Amendment 18 ML23334A1912023-11-30030 November 2023 International, Submittal of Topical Report HI-2210161-A Version ML23321A2172023-11-17017 November 2023 International, Responses to NRC Questions Form EA-23-044 Pre-Decisional Enforcement Conference JAFP-23-0063, Registration of Spent Fuel Cask Use2023-11-13013 November 2023 Registration of Spent Fuel Cask Use ML23310A0362023-11-0909 November 2023 International, Inc. - U.S. Nuclear Regulatory Commission Inspection Report 07201014/2023201 ML23283A1262023-11-0202 November 2023 Letter - Second Request for Additional Information - HI-STORM 100 Amd 18 ML23289A1582023-10-16016 October 2023 Decommissioning International - Registration of Spent Fuel Casks and Notification of Permanent Removal of All Indian Point Unit 3 Spent Fuel Assemblies from the Spent Fuel Pit ML23270A0082023-09-27027 September 2023 Registration of Spent Fuel Casks ML23263B1232023-09-20020 September 2023 HI-STORM 100 Amendment 16 Responses to Second Round Requests for Additional Information ML23234A1572023-09-14014 September 2023 Letter to Holtec International Final Safety Evaluation for Hi-2210161, Revision No. 4, Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems ML23145A1752023-09-12012 September 2023 NRC Choice Letter to Holtec International with Attached Safety Inspection Report, IR 72-1014/2022-201, December 12-15, 2022, Inspection of Holtec International in Camden, New Jersey (Docket Nos.: 72-1014, 72-1032) ML23251A2512023-09-0808 September 2023 International, Submittal of Supplement to RAI Responses on HI-STORM 100 Amendment 18 ML23250A0812023-09-0707 September 2023 Registration of Spent Fuel Casks 2024-09-26
[Table view] |
Text
July 12, 2021 Brian Seawright Licensing Engineer Holtec International Holtec Technology Campus 1 Holtec Blvd.
Camden, NJ 08104
SUBJECT:
ACCEPTANCE REVIEW OF REQUEST FOR AMENDMENT NO. 16 TO CERTIFICATE OF COMPLIANCE NO. 1014 FOR THE HI-STORM 100 MULTIPURPOSE CANISTER STORAGE SYSTEM (DOCKET NO. 72-1014, CAC NO. 001028, EPID: L-2021-LLA-0039) - REQUEST FOR SUPPLEMENTAL INFORMATION
Dear Mr. Seawright:
By letter dated March 9, 2021 [Agencywide Documents Access and Management System (ADAMS) Accession No. ML21068A360], Holtec International (Holtec) submitted to the U.S.
Nuclear Regulatory Commission a request to amend the Certificate of Compliance No. 1014 for HI-STORM 100 Multipurpose Canister Storage System.
The staff has performed an acceptance review of your application to determine if the application contains sufficient technical information to begin a detailed technical review. The staff has determined that the application does not provide sufficient technical information to begin a detailed review and that supplemental information is needed. The information needed to continue our review is described in the request for supplemental information (RSI) in the enclosures to this letter.
In Amendment No. 16, you also proposed to reorganize the certificate of compliance using the process developed and described in RIRP-I-16-01 (ADAMS Accession No. ML17138A119), also referred to as the graded approach. The staff has additional questions regarding this proposed change and plans to discuss this matter in a public meeting.
In order to schedule our technical review, responses to the enclosed RSI should be provided within 30 days from the date of this letter. If Holtec is unable to meet this response date, please notify us, at least one week prior to the due date, of your new submittal date and the reasons for the delay. If Holtec is not able to respond within this timeframe or the RSI responses do not provide sufficient information, the application may not be accepted for review.
B. Seawright Please reference Docket No. 72-1014, CAC No. 001028, and EPID No. L-2021-LLA-0039 in future correspondence related to this licensing action. If you have any questions, please contact me at 301-415-1018.
Sincerely, Signed by Chen, Yen-Ju on 07/12/21 Yen-Ju Chen, Sr. Project Manager Storage & Transportation Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1014 CAC No.: 001208 EPID: L-2021-LLA-0039
Enclosures:
- 1. RSI
- 2. RSI (Proprietary)
Request for Supplemental Information Docket No. 72-1014 Holtec International HI-STORM 100 Multipurpose Canister Storage System Certificate of Compliance No. 1014 Amendment No. 16 Thermal RSI 5-1 See Enclosure 2.
Confinement RSI 9-1 Demonstrate the Proposed Changes #3 and #6 will reasonably maintain confinement of radioactive material under normal, off-normal, and credible accident conditions.
In its Statement of Proposed Changes, the applicant proposed to modify vent and drain penetrations to include the option of second port cover plate (Proposed Change #3).
The applicant also stated that the addition of a second cover plate for these penetrations removes the need to do field helium leak testing of these cover plates (Proposed Change #6).
The weld on the port cover plate cannot be executed under conditions where the root pass might have been subjected to pressurization from the helium filled in the canister itself. When executing vent and drain connection cover plate welds, one should not assume that the fill and drain closure valves quick-disconnects, or similar, are leak tight without performing helium leak testing. It is assumed that mechanical closure devices (e.g., a valve or quick-disconnect) permit helium leaks. Field experience has shown that such leaks occur and have been responsible for causing leak paths through the weld.
Consequently, welds potentially subjected to helium pressure (by way of leakage through a mechanical closure device) during the welding process must be subsequently helium leakage tested in accordance with the method in ANSI N14.5. In addition, ANSI N14.5 does not allow for the elimination of leakage rate testing based on the use of multiple barriers.
This information is required to satisfy 10 CFR 72.236 (d), 72.236 (j), and 72.236 (l).
Observations O-1 The staff recognizes that the HI-STORM 100 Amendment No. 15 (effective on June 14, 2021) and the ongoing renewal may result in additional changes to the Certificate of Compliance (CoC) and safety analysis report (SAR) which may impact Amendment No.
- 16. All application materials for Amendment No. 16 should be updated accordingly to facilitate staffs review.
Enclosure 1
O-2 Provide description of Note 3 shown on Table 2.4-5a of the proposed CoC Appendix D.
The applicant marked Note 3 to the title of Table 2.4-5a, but without providing any description. The applicant should either remove Note 3 from Table 2.4-5a or provide description on Note 3.
The staff needs this information to determine compliance with 10 CFR 72.236(f).
O-3 Provide cask component temperatures for MPC-32M and MPC-68M with heat load pattern No. 3 to ensure that the uniform heat load pattern is the most bounding pattern for both MPC-32M and MPC-68M.
In Report HI-2210138, Revision 0, the applicant shows in Tables 7-1 and 7-2, the uniform heat load patterns for MPC-32M and MPC-68M, respectively, resulted in highest peak cladding temperatures (PCTs) and cavity temperatures; therefore, the applicant concludes the uniform heat load pattern for the respective MPCs is the most bounding pattern.
Staff reviewed Tables 7-1 and 7-2 and found that the PCT of uniform heat load pattern is higher than the PCT of pattern No. 3 by 2°C for MPC-32M and by 1°C for MPC-68M.
With such small PCT differences between uniform heat load pattern and pattern No. 3, the applicant should provide cask component temperatures, similar to Table 7-3, of the heat load patterns No. 3 for MPC-32M and MPC-68M. The staff needs the information to verify and ensure that the uniform heat load pattern is indeed the bounding heat load pattern for MPC-32M and MPC-68M.
The staff needs this information to determine compliance with 10 CFR 72.236(f).
O-4 See Enclosure 2.
O-5 (A) Provide the derivations of the MPC-32M and MPC-68M annulus pressures, as shown in Report HI-2210138, Revision 0, Tables 7-8 and 7-9; and (B) explain the similarity of annulus pressures between MPC-32M and MPC-68M under long-term normal storage, extreme ambient accident, burial under debris accident, and fire accident.
(A) The applicant presented in Report HI-2210138, Revision 0, Tables 7-8 and 7-9, the annulus pressures of MPC-32M and MPC-68M, respectively, for MPC loaded in the unventilated overpack with the bounding heat load pattern in cask array under long-term normal storage, extreme ambient accident, burial under debris accident, and fire accident.
Provide the derivations of these MPC-32M and MPC-68M annulus pressures under the conditions underlined above. The derivation of annulus pressures should include the assumptions, equations (e.g., ideal gas equation), annulus temperature, and parameters (with units) used in the derivation.
(B) Report HI-2210138, Revision 0, Tables 7-3 and 7-4 present the single cask containing MPC maximum component temperatures with uniform heat load for MPC-32M and MPC-68M, respectively. The cask component temperatures for MPC-32M and MPC-68M are different, and it is expected that the difference, when stored in unventilated overpack, would have impact on the temperature and pressure of the annulus between MPCs and unventilated overpack for normal, off-normal, and accident conditions of storage.
Explain why the MPC-32M annulus pressure (Table 7-8) is identical to the MPC-68M annulus pressure (Table 7-9) under each condition of long-term normal storage, extreme ambient accident, burial under debris accident, and fire accident.
The staff needs this information to determine compliance with 10 CFR 72.236(f).
O-6 Clarify the applicability of Proposed Change #5 to MPC types in the application (see item (A) below) and add a requirement (see item (B) below) in the Technical Specifications or SAR Chapter 9 to ensure the minimum heat load limit is adequate to maintain the water in the HI-TRAC water jacket is above the freezing point (0°C/32°F).
The applicant proposed to use water without glycol in the HI-TRAC water jacket during transfer operations below 32°F ambient (Proposed Change #5). In Report HI-2043317, HI-TRAC Thermal Modeling to Address NRC Review Comments for HI-STORM 100 LAR-9, Appendix N.5.19, the applicant stated that the temperature of water in the HI-TRAC water jacket remains above freezing point (32°F) with heat load equal to or above 10 kW, and therefore, the system of MPC-32 in HI-TRAC does not need to be filled with ethylene glycol under allowable operating short-term conditions. The applicant presented the minimum water temperature in Table N.5.23 and stated that this calculation may be performed using the above set of assumptions for any MPC type and for any site-specific ambient conditions.
(A) Clarify whether the proposed change #5 is applicable only to MPC-32 system (including MPC-32M) with heat load equal to or greater than 10 kW or also applicable to MPC-68 system (including MPC-68M) with heat load equal to or greater than 10 kW.
(B) Add a requirement in Technical Specifications or SAR Chapter 9, Operating Procedures, such as the users need to perform thermal evaluation using the site-specific heat loads and ambient conditions to determine the minimum heat load limit for using water without ethylene glycol in the HI-TRAC water jacket during transfer operations below 32°F. This is to ensure the heat load limit is adequate to maintain the water in the HI-TRAC water jacket above the freezing point (0°C/32°F).
(C) Correct the labeling for N.5.19 on page N-25.
The staff needs this information to determine compliance with 10 CFR 72.236(f).
O-7 See Enclosure 2.
ML21179A178; Ltr ML21179A179 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/IOB WWheatley NAME YChen YC YChen YC HLindsay HL SFigueroa for SF DATE Jun 28, 2021 Jun 28, 2021 Jun 28, 2021 Jun 28, 2021 NMSS/DFM OFFICE NMSS/DFM/NARAB NMSS/DFM/MSB NMSS/DUWP/RDB
/CTCFB JMarcano NAME MCall MC FChang FC ZCruz-Perez ZC ZLi for ZL DATE Jun 29, 2021 Jun 28, 2021 Jun 29, 2021 Jun 29, 2021 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NAME JMcKirgan JM YChen YC DATE Jul 12, 2021 Jul 12, 2021