Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5014954 Page 1 of 2 January 4, 2023 Yen Chen, Project Manager Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1014, Certificate of Compliance (CoC) No. 1014 EPID: L-2021-LLA-0039

Subject:

HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 4)

Reference:

[1] Amendment No. 16 To Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System - Request for Additional Information Fourth Batch, letter from Y. Chen (NRC) to D. Elisio (Holtec) dated November 7, 2022. ADAMS Accession No. ML22294A191

[2] Schedule for Responses to HI-STORM 100 Amendment 16 Requests for Additional Information Batch 4, letter from D. Elisio (Holtec) to Y. Chen (NRC) dated November 21, 2022. ADAMS Accession No. ML22325A338

Dear Ms. Chen:

By letter dated November 7, 2022 [1], NRC staff documented Requests for Additional Information (RAI Batch 4) to support review of HI-STORM 100 amendment request 1014-16. On November 21, 2022 [2], Holtec submitted a schedule for the responses to Batch 4 of the RAIs.

The responses to RAIs are provided in Attachment 1, with Attachment 2 being a non-proprietary copy. Changes to the FSAR as a result of these RAIs are included in Attachment 3 and 4 for both proprietary and non-proprietary versions, respectively. Attachment 5 contains a proprietary document supporting the RAI responses. Another supporting proprietary document will be submitted later this week.

Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5014954 Page 2 of 2 Since Attachments 1, 3, and 5 contain proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 6.

Please contact me at (856) 797-0900 Extension 3326 if there are any questions or require any additional information.

Sincerely, Denise Elisio Licensing Engineer Holtec International cc:

(via email)

Yoira Diaz-Sanabria (USNRC)

Kimberly Manzione (Holtec)

Attachments: : HI-STORM 100 Amendment 16 RAI Responses Batch 4 (proprietary) : HI-STORM 100 Amendment 16 RAI Responses Batch 4 (non-proprietary) : HI-STORM 100 FSAR Proposed text changes, changed pages (proprietary) : HI-STORM 100 FSAR Proposed text changes, changed pages (non-proprietary) : HI-STORM 100 UVH Critical Dimension Report (HI-2210277R1) : Affidavit in Accordance with 10 CFR 2.390