Other: ML21223A048, ML21223A049, ML21223A050, ML21223A056, ML22028A372, ML22196A086, ML22243A274, ML22243A278, ML22325A338, ML23005A002, ML23005A006, ML23005A275, ML23013A340, ML23013A341, ML23013A342, ML23013A343, ML23013A344, ML23013A345, ML23013A346, ML23013A347, ML23076A272, ML23076A275, ML23076A278, ML23263B123, ML23263B124, ML23263B125, ML23263B127, ML24178A432, ML24178A433, ML24178A434, ML24178A435, ML24178A436, ML24178A437, ML24178A438
|
MONTHYEARML21068A3612021-03-0909 March 2021 International, Submittal of HI-STORM 100 Multipurpose Canister Storage System Amendment 16 Request Project stage: Request ML21179A1792021-07-12012 July 2021 Acceptance Review of Request for Amendment No. 16 to Certificate of Compliance No. 1014 for HI-STORM 100 Multipurpose Canister Storage System, Request for Supplemental Information Project stage: Acceptance Review ML21237A0422021-07-23023 July 2021, 25 August 2021 Summary of July 27, 2021, Public Meeting on HI-STORM 100, Amendment No. 16, Graded Approach Project stage: Request ML21201A0282021-07-23023 July 2021 Handout for Meeting with Holtec on HI-STORM 100 Amendment No. 16 (July 27, 2021) Project stage: Request ML21223A0452021-08-10010 August 2021, 11 August 2021 HI-STORM 100 Amendment 16 Responses to Requests for Supplemental Information Project stage: Request ML21223A0562021-08-10010 August 2021 Attachment 10: Affidavit in Accordance with 10 CFR 2.390 Project stage: Other ML21223A0502021-08-11011 August 2021 Attachment 4: HI-STORM 100 FSAR Proposed Revision 21A, Changed Pages (non-proprietary) Project stage: Other ML21223A0492021-08-11011 August 2021 Attachment 3: HI-STORM 100 Amendment 16 Certificate of Compliance Appendix D, Changed Pages (non-proprietary) Project stage: Other ML21223A0462021-08-11011 August 2021 HI-STORM 100 Amendment 16 Responses to Requests for Supplemental Information Project stage: Supplement ML21223A0482021-08-11011 August 2021 Attachment 2: HI-STORM 100 Amendment 16 Rsi Responses (non-proprietary) Project stage: Other ML21237A0432021-08-25025 August 2021 Summary of July 27, 2021, Public Meeting with Holtec International to Discuss Certificate of Compliance No. 1014 for the HI-STORM 100, Amendment No. 16, Graded Approach Project stage: Meeting ML22028A3712022-01-28028 January 2022 International, HI-STORM 100 Amendment 16 Additional Information on Graded Approach Project stage: Request ML22028A3722022-01-28028 January 2022 International, HI-STORM 100 Amendment 16 Additional Information on Graded Approach Project stage: Other ML22048C2222022-02-17017 February 2022 International - HI-STORM 100 Multipurpose Canister Storage System Amendment 19 Project stage: Request ML22053A1302022-03-17017 March 2022 Acceptance Review Request for Amendment No. 16 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System (Docket No. 72-1014, CAC No. 001028, EPID: L-2021-LLA-0039) Project stage: Acceptance Review ML22167A1202022-07-0101 July 2022 Amendment No. 16 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System - Request for Additional Information First Batch Project stage: RAI ML22196A0862022-07-15015 July 2022 International, Schedule for Responses to HI-STORM 100 Amendment 16 Requests for Additional Information Batch 1 Project stage: Other ML22243A2742022-08-31031 August 2022 Attachment 4: HI-STORM 100 FSAR Proposed Revision 21B, Changed Pages (non-proprietary) Project stage: Other ML22243A2692022-08-31031 August 2022 HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batches 1 and 2) Project stage: Request ML22243A2722022-08-31031 August 2022 Attachment 2: Holtec Response to Request for Additional Information (Batch 1 and Partial Batch 2) Project stage: Response to RAI ML22243A2702022-08-31031 August 2022 HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batches 1 and 2) Project stage: Response to RAI ML22243A2782022-08-31031 August 2022 Attachment 8: Affidavit in Accordance with 10 CFR 2.390 Project stage: Other ML22249A3472022-09-0606 September 2022, 9 September 2022 International, HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 2) Project stage: Request ML22249A3482022-09-0909 September 2022 International, HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 2) Project stage: Response to RAI ML22276A2872022-10-0303 October 2022 HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 3) Project stage: Response to RAI ML22276A2862022-10-0303 October 2022 HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 3) Project stage: Request ML22325A3382022-11-21021 November 2022 Schedule for Responses to HI-STORM 100 Amendment 16 Requests for Additional Information Batch 4 Project stage: Other ML22335A4552022-12-13013 December 2022 Amendment 16 to Certificate of Compliance 1014 for Hi-Storm 100 RAI Batch 5 Project stage: Request ML22335A4572022-12-13013 December 2022 Enclosure 1- Amendment 16 to Certificate of Compliance No. 1014 for Hi-Storm 100 Multipurpose Canister Storage System Request for Additional Information Batch 5 Project stage: RAI ML22335A4562022-12-13013 December 2022 Letter - Amendment 16 to Certificate of Compliance No. 1014 for Hi-Storm 100 Multipurpose Canister Storage System - Request for Additional Information Batch 5 Project stage: RAI ML23005A0012023-01-0404 January 2023 International HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 4) Project stage: Response to RAI ML23005A0062023-01-0404 January 2023 Attachment 4 - HI-STORM 100 FSAR Proposed Text Changes, Changed Pages Project stage: Other ML23005A0002023-01-0404 January 2023 International HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 4) Project stage: Request ML23005A0022023-01-0404 January 2023 Attachment 6 - Affidavit of Kimberly Manzione Project stage: Other ML23005A0042023-01-0404 January 2023 Attachment 2 - HI-STORM 100 Amendment 16 Response to Request for Additional Information (Batch 4) Project stage: Response to RAI ML23005A2752023-01-0404 January 2023 Attachment 2 - Affidavit of Kimberly Manzione Project stage: Other ML23005A2732023-01-0505 January 2023 International HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 4) – Additional Supporting Document Project stage: Response to RAI ML23013A3412023-01-13013 January 2023 Attachment 3 - HI-STORM 100 Amendment 16 Certificate of Compliance Appendix a, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3432023-01-13013 January 2023 Attachment 5 - HI-STORM 100 Amendment 16 Certificate of Compliance Appendix C, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3402023-01-13013 January 2023 Attachment 2 - HI-STORM 100 Amendment 16 RAI Responses Batch 5 (Non-Proprietary) Project stage: Other ML23013A3452023-01-13013 January 2023 Attachment 7 - HI-STORM 100 Amendment 16 Certificate of Compliance Appendix A-100U, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3462023-01-13013 January 2023 Attachment 8 - HI-STORM 100 FSAR Proposed Revision 21E, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3442023-01-13013 January 2023 Attachment 6 - HI-STORM 100 Amendment 16 Certificate of Compliance Appendix D, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3422023-01-13013 January 2023 Attachment 4 - HI-STORM 100 Amendment 16 Certificate of Compliance Appendix B, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3382023-01-13013 January 2023 International HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 5) Project stage: Response to RAI ML23013A3472023-01-13013 January 2023 Attachment 9 - Affidavit of Kimberly Manzione Project stage: Other ML23013A3372023-01-13013 January 2023 International HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 5) Project stage: Request ML23076A2782023-03-17017 March 2023 Attachment 5: Affidavit Project stage: Other ML23076A2752023-03-17017 March 2023 Attachment 3: HI-STORM 100 FSAR Proposed Text Changes, Changed Pages Project stage: Other ML23076A2742023-03-17017 March 2023 Attachment 2: Holtec Response to Request for Additional Information (Batch 4) Project stage: Response to RAI 2022-02-17
[Table View] |
Text
Certificate of Compliance No. 1014 Appendix D Proposed Amendment No. 16A 2-18 Approved Contents 2.0 TABLE 2.4-5a MPC-32M HEAT LOAD DATA for UNVENTILATED OVERPACK Note 3 Number of Regions: 2 Number of Storage Cells:
32 Maximum Total Heat Load (kW):
25 Maximum Section Heat Load (kW): 3.125 Region No.
(Note 1)
Decay Heat Limit per Cell, kW (Note 2)
Number of Cells per Region Decay Heat Limit per Region, kW 1 (Inner) 0.781 12 9.375 2 (Outer) 0.781 20 15.625 Note 1: Figure 2.1-1 identifies the cell locations. The inner region consists of cells 7, 8,12 through 15,18 through 21, 25 and 26. The outer region is maintained by all other cell locations.
Note 2: Heat load limits provided in this table are for reference length fuel assemblies (144 in.
active length). Maximum total heat load, maximum quadrant heat load and specific cell heat load limits may need to be adjusted in accordance with Section 2.4.4.
TABLE 2.4-5b MPC-32M REQUIREMENTS ON DEVELOPING REGIONALIZED HEAT LOAD PATTERNS for UNVENTILATED OVERPACK (See Figure 2.1-1)
- 1. Total MPC aggregate Heat Load must be equal to 25 kW
- 2. Maximum Section Heat Load must be equal to 3.125 kW, calculated as defined in Table 2.4-6, and pattern must be 1/8th symmetric
- 3. Maximum Heat Load per Cell in Region 1 is 0.781 kW
- 4. Maximum Heat Load per Cell in Region 2 is 1.562 kW
- 5. Pattern-specific Heat Loads in a storage cell may need to be adjusted to meet items 1 and 2
- 6. Pattern-specific Heat Load for storage cells may be determined by reducing the allowable heat load in any Region 1 cell in Table 2.4-5a by a certain amount () and adding the same to a single cell or distributed amongst multiple cells in Region 2. i.e. Any reduction of total allowable heat load in Region 1 must be compensated by an equivalent addition in Region 2.
General Notes -
- 1. Any assembly with a Heat Load less than the limits defined above can be loaded in the applicable cell, provided it meets all other CoC requirements.
- 2. DFCs/DFIs are permitted in locations denoted in Table 2.4-7 with the applicable Heat Load penalties identified therein.
Holtec Letter 5014931 Attachment 3 Page 1 of 1