Line 18: |
Line 18: |
|
| |
|
| =Text= | | =Text= |
| {{#Wiki_filter:January 9, 2007Mr. Randall K. EdingtonVice President-Nuclear Energy and Chief Nuclear Officer Nebraska Public Power District 72676 648A Avenue Brownville, NE 68321 | | {{#Wiki_filter:January 9, 2007 Mr. Randall K. Edington Vice President-Nuclear Energy and Chief Nuclear Officer Nebraska Public Power District 72676 648A Avenue Brownville, NE 68321 |
|
| |
|
| ==SUBJECT:== | | ==SUBJECT:== |
| COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION RE: LICENSE AMENDMENT REQUEST FOR SPENT FUEL POOL STORAGE CAPACITY (TAC NO. MD3349) | | COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION RE: LICENSE AMENDMENT REQUEST FOR SPENT FUEL POOL STORAGE CAPACITY (TAC NO. MD3349) |
|
| |
|
| ==Dear Mr. Edington:== | | ==Dear Mr. Edington:== |
|
| |
|
| By letter dated October 17, 2006, Nebraska Public Power District (the licensee) submitted thelicense amendment request for changes to the Cooper Nuclear Station Technical Specifications (TS) 4.3.1.1.c and TS 4.3.3 to increase the capacity of the spent fuel storage pool.The Nuclear Regulatory Commission staff from the Boiling Water Reactor Systems Branch hasreviewed the information provided in the submittal and determined that additional information is required in order to complete the review and approve the changes. As agreed upon in the telephone call on December 7, 2006, the licensee will respond to the request for additional information (RAI) within 30 days from the date of this letter. The RAI is enclosed.Sincerely,/RA D. Terao for/Bhalchandra K. Vaidya, Project ManagerPlant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-298 | | By letter dated October 17, 2006, Nebraska Public Power District (the licensee) submitted the license amendment request for changes to the Cooper Nuclear Station Technical Specifications (TS) 4.3.1.1.c and TS 4.3.3 to increase the capacity of the spent fuel storage pool. |
| | The Nuclear Regulatory Commission staff from the Boiling Water Reactor Systems Branch has reviewed the information provided in the submittal and determined that additional information is required in order to complete the review and approve the changes. As agreed upon in the telephone call on December 7, 2006, the licensee will respond to the request for additional information (RAI) within 30 days from the date of this letter. The RAI is enclosed. |
| | Sincerely, |
| | /RA D. Terao for/ |
| | Bhalchandra K. Vaidya, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-298 |
|
| |
|
| ==Enclosure:== | | ==Enclosure:== |
| Request for Additional Information cc w/encl: See next page January 9, 2007Mr. Randall K. EdingtonVice President-Nuclear Energy and Chief Nuclear Officer Nebraska Public Power District 72676 648A Avenue Brownville, NE 68321 | | Request for Additional Information cc w/encl: See next page |
| | |
| | January 9, 2007 Mr. Randall K. Edington Vice President-Nuclear Energy and Chief Nuclear Officer Nebraska Public Power District 72676 648A Avenue Brownville, NE 68321 |
|
| |
|
| ==SUBJECT:== | | ==SUBJECT:== |
| COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION RE: LICENSE AMENDMENT REQUEST FOR SPENT FUEL POOL STORAGE CAPACITY (TAC NO. MD3349) | | COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION RE: LICENSE AMENDMENT REQUEST FOR SPENT FUEL POOL STORAGE CAPACITY (TAC NO. MD3349) |
|
| |
|
| ==Dear Mr. Edington:== | | ==Dear Mr. Edington:== |
|
| |
|
| By letter dated October 17, 2006, Nebraska Public Power District (the licensee) submitted thelicense amendment request for changes to the Cooper Nuclear Station Technical Specifications (TS) 4.3.1.1.c and TS 4.3.3 to increase the capacity of the spent fuel storage pool.The Nuclear Regulatory Commission staff from the Boiling Water Reactor Systems Branch hasreviewed the information provided in the submittal and determined that additional information is required in order to complete the review and approve the changes. As agreed upon in the telephone call on December 7, 2006, the licensee will respond to the request for additional information (RAI) within 30 days from the date of this letter. The RAI is enclosed.Sincerely,/RA D. Terao for/Bhalchandra K. Vaidya, Project ManagerPlant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-298 | | By letter dated October 17, 2006, Nebraska Public Power District (the licensee) submitted the license amendment request for changes to the Cooper Nuclear Station Technical Specifications (TS) 4.3.1.1.c and TS 4.3.3 to increase the capacity of the spent fuel storage pool. |
| | The Nuclear Regulatory Commission staff from the Boiling Water Reactor Systems Branch has reviewed the information provided in the submittal and determined that additional information is required in order to complete the review and approve the changes. As agreed upon in the telephone call on December 7, 2006, the licensee will respond to the request for additional information (RAI) within 30 days from the date of this letter. The RAI is enclosed. |
| | Sincerely, |
| | /RA D. Terao for/ |
| | Bhalchandra K. Vaidya, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-298 |
|
| |
|
| ==Enclosure:== | | ==Enclosure:== |
| Request for Additional Information cc w/encl: See next page DISTRIBUTION | | Request for Additional Information cc w/encl: See next page DISTRIBUTION: |
| :PUBLICLPLIV r/fRidsNrrDorlRidsNrrDorlLpl4 RidsNrrPMBVaidyaRidsNrrLAFeizollahiRidsOgcRpRidsAcrsAcnwMailCenter RidsRgn4MailCenterRidsNrrDorlDpr RidsNrrSbwbMRazzaque, SBWBACCESSION NO: ML070030322OFFICENRR/LPL4/PMNRR/LPL4/LANRR/SBWB/BCNRR/LPL4/BCNAMEBVaidya:MF forLFeizollahiGCranstonDTerao DATE1/8/091/4/071/8/071/9/07OFFICIAL RECORD COPY REQUEST FOR ADDITIONAL INFORMATIONISSUES RELATED TO SPENT FUEL POOL STORAGE CAPACITYCOOPER NUCLEAR STATIONDOCKET NO. 50-2981.The Nuclear Regulatory Commission staff requests the licensee to provide the followinginformation that is applicable for the Cooper Nuclear Station Spent Fuel Pool (SFP) expansion for the fuel assemblies expected to be discharged in the future:a)The types of fuel assemblies to be stored.
| | PUBLIC LPLIV r/f RidsNrrDorl RidsNrrDorlLpl4 RidsNrrPMBVaidya RidsNrrLAFeizollahi RidsOgcRp RidsAcrsAcnwMailCenter RidsRgn4MailCenter RidsNrrDorlDpr RidsNrrSbwb MRazzaque, SBWB ACCESSION NO: ML070030322 OFFICE NRR/LPL4/PM NRR/LPL4/LA NRR/SBWB/BC NRR/LPL4/BC NAME BVaidya:MF for LFeizollahi GCranston DTerao DATE 1/8/09 1/4/07 1/8/07 1/9/07 OFFICIAL RECORD COPY |
| b)Uniform average enrichment. | | |
| c)Discharge fuel burnup (MWD/KgU). | | REQUEST FOR ADDITIONAL INFORMATION ISSUES RELATED TO SPENT FUEL POOL STORAGE CAPACITY COOPER NUCLEAR STATION DOCKET NO. 50-298 |
| d)Wt.% of Gd 2 O 3 (Gadolinia burnable poison) and the number of fuel rods thatcontain the Gadolinia.e)The highest actual or calculated value for neutron multiplication factor (Keff) withthe racks fully loaded with fuel of the highest anticipated reactivity and pool flooded with unborated water at a temperature corresponding to the highest reactivity.f)The highest actual or calculated value for K-infinity. 2.Please confirm that each of the limiting criteria for acceptable storage, as listed inTable 4-3 of Enclosure 1 of the submittal, are satisfied in the SFP expansion. If any of the criteria are not satisfied, then identify it and provide justification for acceptability. | | : 1. The Nuclear Regulatory Commission staff requests the licensee to provide the following information that is applicable for the Cooper Nuclear Station Spent Fuel Pool (SFP) expansion for the fuel assemblies expected to be discharged in the future: |
| December 2006Cooper Nuclear Station cc:Mr. Ronald D. Asche President and Chief Executive Officer Nebraska Public Power District
| | a) The types of fuel assemblies to be stored. |
| | b) Uniform average enrichment. |
| | c) Discharge fuel burnup (MWD/KgU). |
| | d) Wt.% of Gd2O3 (Gadolinia burnable poison) and the number of fuel rods that contain the Gadolinia. |
| | e) The highest actual or calculated value for neutron multiplication factor (Keff) with the racks fully loaded with fuel of the highest anticipated reactivity and pool flooded with unborated water at a temperature corresponding to the highest reactivity. |
| | f) The highest actual or calculated value for K-infinity. |
| | : 2. Please confirm that each of the limiting criteria for acceptable storage, as listed in Table 4-3 of Enclosure 1 of the submittal, are satisfied in the SFP expansion. If any of the criteria are not satisfied, then identify it and provide justification for acceptability. |
| | |
| | Cooper Nuclear Station cc: |
| | Mr. Ronald D. Asche Mr. H. Floyd Gilzow President and Chief Executive Officer Deputy Director for Policy Nebraska Public Power District Missouri Department of Natural Resources 1414 15th Street P.O. Box 176 Columbus, NE 68601 Jefferson City, MO 65102-0176 Mr. Gene Mace Senior Resident Inspector Nuclear Asset Manager U.S. Nuclear Regulatory Commission Nebraska Public Power District P.O. Box 218 P.O. Box 98 Brownville, NE 68321 Brownville, NE 68321 Regional Administrator, Region IV Mr. John C. McClure U.S. Nuclear Regulatory Commission Vice President and General Counsel 611 Ryan Plaza Drive, Suite 400 Nebraska Public Power District Arlington, TX 76011 P.O. Box 499 Columbus, NE 68602-0499 Director, Missouri State Emergency Management Agency Mr. Paul V. Fleming P.O. Box 116 Licensing Manager Jefferson City, MO 65102-0116 Nebraska Public Power District P.O. Box 98 Chief, Radiation and Asbestos Brownville, NE 68321 Control Section Kansas Department of Health Mr. Michael J. Linder, Director and Environment Nebraska Department of Environmental Bureau of Air and Radiation Quality 1000 SW Jackson P.O. Box 98922 Suite 310 Lincoln, NE 68509-8922 Topeka, KS 66612-1366 Chairman Mr. Donald A. Flater Nemaha County Board of Commissioners Radiation Control Program Director Nemaha County Courthouse Bureau of Radiological Health 1824 N Street Iowa Department of Public Health Auburn, NE 68305 Lucas State Office Building, 5th Floor 321 East 12th Street Ms. Julia Schmitt, Manager Des Moines, IA 50319 Radiation Control Program Nebraska Health & Human Services R & L Mr. Daniel K. McGhee Public Health Assurance Bureau of Radiological Health 301 Centennial Mall, South Iowa Department of Public Health P.O. Box 95007 Lucas State Office Building, 5th Floor Lincoln, NE 68509-5007 321 East 12th Street Des Moines, IA 50319 December 2006 |
|
| |
|
| 1414 15 th StreetColumbus, NE 68601Mr. Gene MaceNuclear Asset Manager Nebraska Public Power District P.O. Box 98 Brownville, NE 68321Mr. John C. McClureVice President and General Counsel Nebraska Public Power District P.O. Box 499 Columbus, NE 68602-0499Mr. Paul V. FlemingLicensing Manager Nebraska Public Power District P.O. Box 98 Brownville, NE 68321Mr. Michael J. Linder, Director Nebraska Department of Environmental Quality P.O. Box 98922 Lincoln, NE 68509-8922Chairman Nemaha County Board of Commissioners Nemaha County Courthouse 1824 N Street Auburn, NE 68305Ms. Julia Schmitt, Manager Radiation Control Program Nebraska Health & Human Services R & L Public Health Assurance 301 Centennial Mall, South P.O. Box 95007 Lincoln, NE 68509-5007Mr. H. Floyd GilzowDeputy Director for Policy Missouri Department of Natural Resources P.O. Box 176 Jefferson City, MO 65102-0176Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 218 Brownville, NE 68321Regional Administrator, Region IVU.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011Director, Missouri State Emergency Management Agency P.O. Box 116 Jefferson City, MO 65102-0116Chief, Radiation and Asbestos Control Section Kansas Department of Health and Environment Bureau of Air and Radiation 1000 SW Jackson Suite 310 Topeka, KS 66612-1366Mr. Donald A. FlaterRadiation Control Program Director Bureau of Radiological Health Iowa Department of Public Health Lucas State Office Building, 5th Floor 321 East 12th Street Des Moines, IA 50319Mr. Daniel K. McGheeBureau of Radiological Health Iowa Department of Public Health Lucas State Office Building, 5th Floor 321 East 12th Street Des Moines, IA 50319 Cooper Nuclear Station-2-December 2006 cc:Mr. Keith G. Henke, Planner Division of Community and Public Health Office of Emergency Coordination 930 Wildwood P.O. Box 570 Jefferson City, MO 65102Jerry C. Roberts, Director of Nuclear Safety Assurance Nebraska Public Power District P.O. Box 98 Brownville, NE 68321Mr. John F. McCann, DirectorLicensing, Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.
| | Cooper Nuclear Station cc: |
| 440 Hamilton Avenue White Plains, NY 10601-1813}}
| | Mr. Keith G. Henke, Planner Mr. John F. McCann, Director Division of Community and Public Health Licensing, Entergy Nuclear Northeast Office of Emergency Coordination Entergy Nuclear Operations, Inc. |
| | 930 Wildwood P.O. Box 570 440 Hamilton Avenue Jefferson City, MO 65102 White Plains, NY 10601-1813 Jerry C. Roberts, Director of Nuclear Safety Assurance Nebraska Public Power District P.O. Box 98 Brownville, NE 68321 December 2006}} |
Letter Sequence RAI |
---|
|
|
MONTHYEARML0700303222007-01-0909 January 2007 Request for Additional Information License Amendment Request for Spent Fuel Pool Storage Capacity Project stage: RAI ML0635407392007-01-12012 January 2007 Individual Notice of Consideration of Issuance of Amendment to Facility Operating License and Opportunity for a Hearing in Conjunction with the Expansion of Spent Fuel Pool Storage Capacity Project stage: Other ML0635407342007-01-12012 January 2007 Letter to License Individual Notice of Consideration of Issuance of Amendment to Facility Operating License and Opportunity for a Hearing in Conjunction with the Expansion of Spent Fuel Pool Storage Capacity Project stage: Other ML0704502422007-02-27027 February 2007 Withholding from Public Disclosure, Table 4-1 of Hi (Holtec International)-2043224, MD3349 Project stage: Other ML0704502372007-02-27027 February 2007 Request for Withholding Information from Public Disclosure - Holtec International Project stage: Withholding Request Acceptance ML0704003662007-02-27027 February 2007 Request for Withholding Information from Public Disclosure - Global Nuclear Fuel - Americas, LLC 1/24/07 Affidavit Project stage: Withholding Request Acceptance ML0705902302007-03-0505 March 2007 Request for Additional Information - License Amendment Request Onsite Spent Fuel Storage Expansion Project stage: RAI ML0708201972007-03-15015 March 2007 H. Floyd Gilzow, State of Missouri Department of Natural Resources, Letter to C. Lyon, NRC, Cooper Nuclear Station - Request for Withholding Information from Public Disclosure Project stage: Withholding Request NLS2007012, Non-Proprietary Version of Response to Request for Additional Information Regarding License Amendment Request for Onsite Spent Fuel Storage Expansion2007-04-17017 April 2007 Non-Proprietary Version of Response to Request for Additional Information Regarding License Amendment Request for Onsite Spent Fuel Storage Expansion Project stage: Response to RAI NLS2007040, Affidavit Requesting Withholding from Public Disclosure Regarding Response to Request for Additional Information to Support NRC Review of License Amendment Request to Increase Capacity of Onsite Spent Fuel Storage at Cooper2007-05-0404 May 2007 Affidavit Requesting Withholding from Public Disclosure Regarding Response to Request for Additional Information to Support NRC Review of License Amendment Request to Increase Capacity of Onsite Spent Fuel Storage at Cooper Project stage: Response to RAI ML0714903152007-05-23023 May 2007 Response to Informal RAI Regarding Spent Fuel Pool Expansion Amendment Request Project stage: Other NLS2007056, Revised Page from Holtec International Non-Proprietary Report2007-07-26026 July 2007 Revised Page from Holtec International Non-Proprietary Report Project stage: Request ML0721300052007-08-28028 August 2007 Letter and Federal Register Notice of Environmental Assessment and Finding of No Significant Impact Onsite Spent Fuel Storage Expansion Project stage: Other ML0721300232007-09-0606 September 2007 License Amendment, Issuance of Amendment No. 227 Onsite Spent Fuel Storage Expansion Project stage: Approval 2007-04-17
[Table View] |
|
---|
Category:Letter
MONTHYEARIR 05000298/20240032024-11-0505 November 2024 Integrated Inspection Report 05000298/2024003 ML24250A2052024-10-0808 October 2024 Issuance of Amendment No. 278 Regarding Revision to Technical Specification Table 3.3.2.1-1 and Transfer of Minimum Critical Power Ratio Values to Core Operating Limit Report ML24227A0822024-09-0303 September 2024 Summary of Regulatory Audit in Support of License Amendment Request to Modify the High Pressure Coolant Injection Low Flow Value IR 05000298/20240052024-08-22022 August 2024 Updated Inspection Plan for Cooper Nuclear Station (Report 05000298/2024005) IR 05000298/20240022024-07-25025 July 2024 Integrated Inspection Report 05000298/2024002 ML24183A1722024-07-17017 July 2024 Issuance of Amendment No. 277 to Adopt TSTF-374, Revision to TS 5.5.13 and Associated TS Bases for Diesel Fuel Oil ML24197A1462024-07-15015 July 2024 NRC Region IV Ltr to Cooper Nuclear Station Re FEMA Level 1 Finding ML24134A1782024-07-0303 July 2024 Issuance of Amendment No. 276 Revision to Technical Specification 3.8.3, Diesel Fuel Oil, Lube Oil and Starting Air, to Allow for Cleaning, Inspection and Any Needed Repairs During Refuel Outage 33 ML24197A0682024-06-24024 June 2024 FEMA Ltr to Missouri State Emergency Management Agency - Level 1 Finding, 24 June 2024 ML24192A0112024-06-13013 June 2024 2024-06-Post Exam Comments 05000298/LER-2023-002-01, Secondary Containment Differential Pressure Perturbation Exceeds Technical Specifications2024-06-0606 June 2024 Secondary Containment Differential Pressure Perturbation Exceeds Technical Specifications IR 05000298/20244012024-06-0404 June 2024 Security Baseline Inspection Report 05000298/2024401 ML24151A1082024-05-30030 May 2024 NRC Initial Operator Licensing Examination Approval 05000298/2024301 ML24137A0942024-05-17017 May 2024 Regulatory Audit Plan in Support of License Amendment Request to Modify Allowable Value Regarding Technical Specification for High Pressure Coolant Injection Pump Discharge Low Flow 05000298/LER-2024-005, High Pressure Coolant Injection Pressure Switch Installation Causes Condition That Could Have Prevented Fulfillment of a Safety Function and a Condition Prohibited B Technical2024-05-13013 May 2024 High Pressure Coolant Injection Pressure Switch Installation Causes Condition That Could Have Prevented Fulfillment of a Safety Function and a Condition Prohibited B Technical. 05000298/LER-2024-004, Main Turbine Stop Valve Position Switches Do Not Meet Channel Independence Criteria Results in Two Channels Being Declared Inoperable and a Condition Prohibited by Technical Specifications2024-05-0909 May 2024 Main Turbine Stop Valve Position Switches Do Not Meet Channel Independence Criteria Results in Two Channels Being Declared Inoperable and a Condition Prohibited by Technical Specifications IR 05000298/20240012024-05-0303 May 2024 Integrated Inspection Report 05000298/2024001 ML24129A0952024-04-25025 April 2024 Preparation and Scheduling of Operator Licensing Examinations IR 05000298/20240102024-04-24024 April 2024 Comprehensive Engineering Team Inspection Report 05000298/2024010 05000298/LER-2024-003, High Pressure Coolant Injection Steam Leak Causes Condition That Could Have Prevented Fulfillment of a Safety Function and a Condition Prohibited by Technical Specifications2024-04-22022 April 2024 High Pressure Coolant Injection Steam Leak Causes Condition That Could Have Prevented Fulfillment of a Safety Function and a Condition Prohibited by Technical Specifications ML24096A1202024-04-0505 April 2024 Issuance of Amendment No. 275 Revision to Technical Specification 3.3.1.1 (Emergency Circumstances) ML24093A2282024-04-0202 April 2024 Notice of Enforcement Discretion for Cooper Nuclear Station IR 05000298/20240902024-04-0101 April 2024 – Notice of Violation, NRC Inspection Report 05000298/2024090 05000298/LER-2024-002, Technical Specifications Prohibited Condition for Inoperable Service Water Booster Pump2024-03-0404 March 2024 Technical Specifications Prohibited Condition for Inoperable Service Water Booster Pump 05000298/LER-2024-001, Inoperable Turbine Stop Valve Limit Switch Causes Condition Prohibited by Technical Specifications2024-03-0404 March 2024 Inoperable Turbine Stop Valve Limit Switch Causes Condition Prohibited by Technical Specifications IR 05000298/20230062024-02-28028 February 2024 Annual Assessment Letter for Cooper Nuclear Station - Report 05000298/2023006 IR 05000298/20230042024-02-12012 February 2024 Integrated Inspection Report 05000298/2023004 ML24033A3092024-02-12012 February 2024 Summary of Regulatory Audit Regarding the Relief Request RC3-02 Regarding Drywell Head Bolting IR 05000298/20230122024-02-12012 February 2024 NRC Inspection Report 05000298/2023012 ML23334A2012024-01-0303 January 2024 Issuance of Amendment No. 274 Revision to Technical Specifications to Adopt TSTF-551, Revision 3, Revise Secondary Containment Surveillance Requirements 05000298/LER-2023-002, Secondary Containment Differential Pressure Perturbation Exceeds Technical Specifications2023-12-20020 December 2023 Secondary Containment Differential Pressure Perturbation Exceeds Technical Specifications ML23311A1122023-11-0909 November 2023 Project Manager Assignment ML23311A2082023-11-0909 November 2023 Reassignment of U.S. Nuclear Regulatory Commission Branch Chief in the Division of Operating Reactor Licensing for Plant Licensing Branch IV IR 05000298/20230032023-11-0202 November 2023 Integrated Inspection Report 05000298/2023003 IR 05000298/20234012023-11-0101 November 2023 Cyber Security Report 05000298/2023401 Public ML23264A8052023-10-11011 October 2023 Issuance of Amendment No. 273 Revision to Technical Specifications to Adopt TSTF-580, Revision 1, Provide Exception from Entering Mode 4 with No Operable RHR Shutdown Cooling ML23233A1882023-09-0505 September 2023 Regulatory Audit Plan in Support of Relief Request RC3-02 Regarding Drywell Head Bolting IR 05000298/20243012023-09-0101 September 2023 Notification of NRC Initial Operator Licensing Examination 05000298/2024301 IR 05000298/20230052023-08-21021 August 2023 Updated Inspection Plan for Cooper Nuclear Station (Report 05000298/2023005)- Mid Cycle Letter IR 05000298/20230022023-08-0808 August 2023 Integrated Inspection Report 05000298/2023002 ML23214A2742023-08-0303 August 2023 Nuclear Station - Notification of Inspection (NRC Inspection Report 05000298/2023004) and Request for Information IR 05000298/20234022023-08-0303 August 2023 NRC Security Inspection Report 05000298/2023402 IR 05000298/20234202023-08-0101 August 2023 Security Baseline Inspection Report 05000298/2023420 05000298/LER-2022-002-01, Manual Core Spray Injection to Restore Skimmer Surge Tank Level2023-06-29029 June 2023 Manual Core Spray Injection to Restore Skimmer Surge Tank Level ML23173A0862023-06-26026 June 2023 Information Request for the Cybersecurity Baseline Inspection, Notification to Perform Inspection 05000298/2023401 IR 05000298/20230102023-05-17017 May 2023 Biennial Problem Identification and Resolution Inspection Report 05000298/2023010 05000298/LER-2022-004-01, 1 for Cooper Nuclear Station, Manual Reactor Scram and Group I Isolation Due to Main Turbine Bypass Valve Failing Open2023-05-11011 May 2023 1 for Cooper Nuclear Station, Manual Reactor Scram and Group I Isolation Due to Main Turbine Bypass Valve Failing Open 05000298/LER-2023-001, Valve Test Failures Result in Condition Prohibited by Technical Specifications2023-05-0808 May 2023 Valve Test Failures Result in Condition Prohibited by Technical Specifications IR 05000298/20234032023-05-0404 May 2023 Security Baseline Inspection Report 05000298/2023403 ML23129A2822023-04-20020 April 2023 Submittal of Revision 31 to Updated Safety Analysis Report 2024-09-03
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML24094A2462024-04-0303 April 2024 NRR E-mail Capture - Cooper Nuclear Station - RAI Emergency LAR Turbine Stop Valve Limit Switch TS 3.3.1.1 ML24032A2382024-02-0101 February 2024 NRR E-mail Capture - Cooper Nuclear Station - LAR Dfo Tank Inspection RAI Issuance ML24010A1172024-01-10010 January 2024 NRR E-mail Capture - Cooper Nuclear Station - LAR Dfo Tank Inspection RAI Issuance ML24010A0902024-01-0404 January 2024 RAI - 10120-R1 - Final Dfo Tank Inspections LAR ML23352A2472023-12-18018 December 2023 NRR E-mail Capture - Cooper Nuclear Station - Relief Request RC3-02 Drywell Head Inspection RAI Issuance ML23257A2192023-09-14014 September 2023 NRR E-mail Capture - Cooper - Final RAI LAR to Adopt TSTF-551, Revision 3 ML22276A1562022-10-0505 October 2022 Notification of Commercial Grade Dedication Inspection 05000298/2023011 and Request for Information ML22208A0642022-07-26026 July 2022 Notification of Inspection and Request for Information for NRC Inspection Report 05000298/2022004 ML22179A3152022-06-28028 June 2022 Notification of Post-Approval Site Inspection for License Renewal (Phase 4) (NRC Inspection Report 05000298/2022011) and Request for Information ML22010A2632022-01-10010 January 2022 NRR E-mail Capture - Cooper - Final RAI Relief Request RR5-01 Revision 1 ML21321A3742021-11-10010 November 2021 NRR E-mail Capture - Cooper - Final RAI Alternative Request RI5-02 Revision 3 ML21258A2632021-09-15015 September 2021 NRR E-mail Capture - Cooper - Final RAI Alternative Request RS-01 ML21109A2222021-04-15015 April 2021 Email with RFI Document for CNS PIR 2021012 ML21026A3112021-01-27027 January 2021 Notification of NRC Design Bases Assurance Inspection (Team) (NRC Inspection Report 05000298/2021010) and Initial Request for Information ML20315A3922020-11-10010 November 2020 Email 11-10-2020 - Cooper EP Prog Insp RFI ML20203M3692020-07-21021 July 2020 NRR E-mail Capture - Cooper - Final RAI License Amendment Request for Approval of EAL Scheme Change (EPID L-LLA-2020-0028) ML18306A5582018-10-30030 October 2018 Notification of Cyber Security Inspection(Nrc Inspection Report 05000298/2019410) and Request for Information ML18060A0272018-02-28028 February 2018 Enclosurequest for Additional Information (Letter to J. Shaw Request for Additional Information Regarding Nebraska Public Power District'S Decommissioning Funding Plan Update for Cooper Nuclear Station ISFSI) ML18037B0002018-02-0606 February 2018 NRR E-mail Capture - Cooper Nuclear Station - Final RAI Relief Requests RR-02 and RR-03 (EPIDs L-2017-LRR-065 and -066) ML18025C0042018-01-25025 January 2018 Notification of NRC Design Bases Assurance Inspection (Teams) (05000298/2018011) and Initial Request for Information ML18024A3752018-01-24024 January 2018 NRR E-mail Capture - Cooper Nuclear Station - Final RAI LAR to Adopt TSTF-542 (CAC MG0138; EPID L-2017-LLA-0290) IR 05000298/20170032017-11-13013 November 2017 NRC Integrated Inspection Report 05000298/2017003 and Independent Spent Fuel Storage Installation Inspection Report 07200066/2017001 ML17177A2432017-06-26026 June 2017 Notification of NRC Design Bases Assurance Inspection (Programs) (05000298/2017007) and Initial Request for Information ML17024A3292016-12-15015 December 2016 NRR E-mail Capture - Rec 2.1 Seismic: Cooper'S SFP Evaluation ML16335A0152016-11-29029 November 2016 NRR E-mail Capture - Cooper Nuclear Station - Formal Request for Additional Information Concerning License Amendment Request to Adopt TSTF-425 Revision 3 ML16112A2732016-04-21021 April 2016 Notification of NRC Triennial Fire Protection Baseline Inspection (05000298/2016008) and Request for Information ML15107A2542015-05-0404 May 2015 Request for Additional Information Associated with Near-Term Task Force Recommendation 2.1, Seismic Hazard and Screening Report ML15051A4872015-02-20020 February 2015 Notification of NRC Component Design Bases Inspection 05000298/2015007 and Initial Request for Information ML13323A1052013-12-0404 December 2013 Interim Staff Evaluation and Request for Additional Information, Overall Integrated Plan in Response to 3/12/12 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) ML13304B4182013-11-0101 November 2013 Request for Additional Information Associated with Near-Term Task Force Recommendation 2.3, Seismic Walkdowns ML13256A0822013-09-12012 September 2013 Request for Additional Information Email, Overall Integrated Plan in Response to 3/12/12 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) ML13246A3482013-08-29029 August 2013 Draft Request for Additional Information Email, Overall Integrated Plan in Response to 3/12/12 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) NLS2013082, Letter Requesting Information from the United States Army Corps of Engineers to Provide Response to March 12, 2012 Letter Regarding Enclosure 2, Recommendation 2.1, Flooding2013-08-22022 August 2013 Letter Requesting Information from the United States Army Corps of Engineers to Provide Response to March 12, 2012 Letter Regarding Enclosure 2, Recommendation 2.1, Flooding ML13155A0112013-06-0303 June 2013 Request for Additional Information Email, 2013 Decommissioning Funding Status Report ML13133A0802013-05-24024 May 2013 (Redacted) - Request for Additional Information, Review of License Renewal Commitment NLS2009100-1 - Core Rim Plate Bolts ML13144A5202013-05-24024 May 2013 Request for Additional Information Email, Decommissioning Funding Status Report ML13095A1602013-04-0404 April 2013 Email, Draft Request for Additional Information - Review of License Renewal Commitment NLS2009100-1 - Core Rim Plate Bolts ML13059A3452013-03-0808 March 2013 Request for Additional Information, License Amendment Request to Revise the Updated Safety Analysis Report to Reflect Changes to Fuel Handling Accident Dose Calculation ML13053A3422013-02-22022 February 2013 E-mail, Draft Request for Additional Information, License Amendment Request to Revise the Updated Safety Analysis Report to Reflect Changes to Fuel Handling Accident Dose Calculation ML12338A2642012-12-0303 December 2012 Email, Round 3, Request for Additional Information, License Amendment Request to Revise Technical Specification 3.4.9, RCS Pressure and Temperature (P/T) Limits, to Revise Limit Curves and SRs ML12312A2812012-11-14014 November 2012 Request for Additional Information, License Amendment Request to Adopt National Fire Protection Agency (NFPA) 805, Performance-Based Standard for Fire Protection for LWR Electric Generating Plants ML12283A4002012-10-0909 October 2012 Email, Draft Request for Additional Information, License Amendment Request to Adopt National Fire Protection Agency (NFPA)-805 Performance-Based Standard for Fire Protection for LWR Electric Generating Plants ML12251A0582012-09-0606 September 2012 Request for Additional Information, License Amendment Request, Round 2, Revise Technical Specifications to Implement a 24-Month Fuel Cycle and Adopt TSTF-493, Revision 4, Option a ML12235A2522012-09-0505 September 2012 Request for Additional Information License Amendment Request to Revise Technical Specifications - Safety Limit Minimum Critical Power Ratio ML12205A2162012-08-10010 August 2012 Request for Additional Information, Round 2, License Amendment Request to Revise Technical Specification 3.4.9, RCS Pressure and Temperature (P/T) Limits, to Revise Limit Curves and Surveillance Requirements ML1217400512012-06-21021 June 2012 List of Questions for Supplement to Complete Acceptance Review, License Amendment Request to Adopt NFPA-805 Performance-Based Standard for Fire Protection for LWR Electric Generating Plants ML12159A2992012-06-11011 June 2012 Request for Additional Information, Relief Request RI-07 from ASME Code Requirements for Residual Heat Removal Shell Circumferential and Nozzle to Head Welds, Fourth 4th 10-Year Inservice Inspection Interval ML12157A5412012-06-11011 June 2012 Second Request for Additional Information Request for Relief for the Fourth 10-Year Pump and Value Inservice Testing Program ML12153A0642012-05-31031 May 2012 Notification of Inspection (NRC Inspection Report 05000298/2012005) and Request for Information ML1213905092012-05-18018 May 2012 Email, Draft Request for Additional Information, Second Round, Relief Request Nos. RV-07 and RV-01, Revision 1, Fourth 10-Year Inservice Testing Program Interval 2024-04-03
[Table view] |
Text
January 9, 2007 Mr. Randall K. Edington Vice President-Nuclear Energy and Chief Nuclear Officer Nebraska Public Power District 72676 648A Avenue Brownville, NE 68321
SUBJECT:
COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION RE: LICENSE AMENDMENT REQUEST FOR SPENT FUEL POOL STORAGE CAPACITY (TAC NO. MD3349)
Dear Mr. Edington:
By letter dated October 17, 2006, Nebraska Public Power District (the licensee) submitted the license amendment request for changes to the Cooper Nuclear Station Technical Specifications (TS) 4.3.1.1.c and TS 4.3.3 to increase the capacity of the spent fuel storage pool.
The Nuclear Regulatory Commission staff from the Boiling Water Reactor Systems Branch has reviewed the information provided in the submittal and determined that additional information is required in order to complete the review and approve the changes. As agreed upon in the telephone call on December 7, 2006, the licensee will respond to the request for additional information (RAI) within 30 days from the date of this letter. The RAI is enclosed.
Sincerely,
/RA D. Terao for/
Bhalchandra K. Vaidya, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-298
Enclosure:
Request for Additional Information cc w/encl: See next page
January 9, 2007 Mr. Randall K. Edington Vice President-Nuclear Energy and Chief Nuclear Officer Nebraska Public Power District 72676 648A Avenue Brownville, NE 68321
SUBJECT:
COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION RE: LICENSE AMENDMENT REQUEST FOR SPENT FUEL POOL STORAGE CAPACITY (TAC NO. MD3349)
Dear Mr. Edington:
By letter dated October 17, 2006, Nebraska Public Power District (the licensee) submitted the license amendment request for changes to the Cooper Nuclear Station Technical Specifications (TS) 4.3.1.1.c and TS 4.3.3 to increase the capacity of the spent fuel storage pool.
The Nuclear Regulatory Commission staff from the Boiling Water Reactor Systems Branch has reviewed the information provided in the submittal and determined that additional information is required in order to complete the review and approve the changes. As agreed upon in the telephone call on December 7, 2006, the licensee will respond to the request for additional information (RAI) within 30 days from the date of this letter. The RAI is enclosed.
Sincerely,
/RA D. Terao for/
Bhalchandra K. Vaidya, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-298
Enclosure:
Request for Additional Information cc w/encl: See next page DISTRIBUTION:
PUBLIC LPLIV r/f RidsNrrDorl RidsNrrDorlLpl4 RidsNrrPMBVaidya RidsNrrLAFeizollahi RidsOgcRp RidsAcrsAcnwMailCenter RidsRgn4MailCenter RidsNrrDorlDpr RidsNrrSbwb MRazzaque, SBWB ACCESSION NO: ML070030322 OFFICE NRR/LPL4/PM NRR/LPL4/LA NRR/SBWB/BC NRR/LPL4/BC NAME BVaidya:MF for LFeizollahi GCranston DTerao DATE 1/8/09 1/4/07 1/8/07 1/9/07 OFFICIAL RECORD COPY
REQUEST FOR ADDITIONAL INFORMATION ISSUES RELATED TO SPENT FUEL POOL STORAGE CAPACITY COOPER NUCLEAR STATION DOCKET NO. 50-298
- 1. The Nuclear Regulatory Commission staff requests the licensee to provide the following information that is applicable for the Cooper Nuclear Station Spent Fuel Pool (SFP) expansion for the fuel assemblies expected to be discharged in the future:
a) The types of fuel assemblies to be stored.
b) Uniform average enrichment.
c) Discharge fuel burnup (MWD/KgU).
d) Wt.% of Gd2O3 (Gadolinia burnable poison) and the number of fuel rods that contain the Gadolinia.
e) The highest actual or calculated value for neutron multiplication factor (Keff) with the racks fully loaded with fuel of the highest anticipated reactivity and pool flooded with unborated water at a temperature corresponding to the highest reactivity.
f) The highest actual or calculated value for K-infinity.
- 2. Please confirm that each of the limiting criteria for acceptable storage, as listed in Table 4-3 of Enclosure 1 of the submittal, are satisfied in the SFP expansion. If any of the criteria are not satisfied, then identify it and provide justification for acceptability.
Cooper Nuclear Station cc:
Mr. Ronald D. Asche Mr. H. Floyd Gilzow President and Chief Executive Officer Deputy Director for Policy Nebraska Public Power District Missouri Department of Natural Resources 1414 15th Street P.O. Box 176 Columbus, NE 68601 Jefferson City, MO 65102-0176 Mr. Gene Mace Senior Resident Inspector Nuclear Asset Manager U.S. Nuclear Regulatory Commission Nebraska Public Power District P.O. Box 218 P.O. Box 98 Brownville, NE 68321 Brownville, NE 68321 Regional Administrator, Region IV Mr. John C. McClure U.S. Nuclear Regulatory Commission Vice President and General Counsel 611 Ryan Plaza Drive, Suite 400 Nebraska Public Power District Arlington, TX 76011 P.O. Box 499 Columbus, NE 68602-0499 Director, Missouri State Emergency Management Agency Mr. Paul V. Fleming P.O. Box 116 Licensing Manager Jefferson City, MO 65102-0116 Nebraska Public Power District P.O. Box 98 Chief, Radiation and Asbestos Brownville, NE 68321 Control Section Kansas Department of Health Mr. Michael J. Linder, Director and Environment Nebraska Department of Environmental Bureau of Air and Radiation Quality 1000 SW Jackson P.O. Box 98922 Suite 310 Lincoln, NE 68509-8922 Topeka, KS 66612-1366 Chairman Mr. Donald A. Flater Nemaha County Board of Commissioners Radiation Control Program Director Nemaha County Courthouse Bureau of Radiological Health 1824 N Street Iowa Department of Public Health Auburn, NE 68305 Lucas State Office Building, 5th Floor 321 East 12th Street Ms. Julia Schmitt, Manager Des Moines, IA 50319 Radiation Control Program Nebraska Health & Human Services R & L Mr. Daniel K. McGhee Public Health Assurance Bureau of Radiological Health 301 Centennial Mall, South Iowa Department of Public Health P.O. Box 95007 Lucas State Office Building, 5th Floor Lincoln, NE 68509-5007 321 East 12th Street Des Moines, IA 50319 December 2006
Cooper Nuclear Station cc:
Mr. Keith G. Henke, Planner Mr. John F. McCann, Director Division of Community and Public Health Licensing, Entergy Nuclear Northeast Office of Emergency Coordination Entergy Nuclear Operations, Inc.
930 Wildwood P.O. Box 570 440 Hamilton Avenue Jefferson City, MO 65102 White Plains, NY 10601-1813 Jerry C. Roberts, Director of Nuclear Safety Assurance Nebraska Public Power District P.O. Box 98 Brownville, NE 68321 December 2006