* Ralery . N C. 27602 SEP 071989 A. 8 CUTTER                                                          SERIAL: NLS-89-255 Vice President                                                      10 CFR 50.62 Nuclear Services Department United States Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, DC 20555 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-325 & 50-324/ LICENSE NOS. DPR-71 & DPR-62 ATWS ARI SYSTEM DESIGN (NRC TAC NOS. 73351/73352)
* Ralery . N C. 27602 SEP 071989 A. 8 CUTTER                                                          SERIAL: NLS-89-255 Vice President                                                      10 CFR 50.62 Nuclear Services Department United States Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, DC 20555 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-325 & 50-324/ LICENSE NOS. DPR-71 & DPR-62 ATWS ARI SYSTEM DESIGN (NRC TAC NOS. 73351/73352)
Gentlemen:
Gentlemen:
In a letter dated August 21, 1989, the NRC informed Carolina Power & Light Company (CP&L) of their conclusion that the "as-built" alternate rod injection (ARI) system at Brunswick is not in agreement with the ATWS Rule Guidance.
In a {{letter dated|date=August 21, 1989|text=letter dated August 21, 1989}}, the NRC informed Carolina Power & Light Company (CP&L) of their conclusion that the "as-built" alternate rod injection (ARI) system at Brunswick is not in agreement with the ATWS Rule Guidance.
Specifically, the ARI system is not powered independently from the reactor trip system (RTS). The Company was requested to advise the Staff, within 15 days, of whether the guidance of the rule will be met for this system.
Specifically, the ARI system is not powered independently from the reactor trip system (RTS). The Company was requested to advise the Staff, within 15 days, of whether the guidance of the rule will be met for this system.
Carolina Power & Light Company is reviewing the existing design of the Brunswick ARI system against the requirements of ATWS Rule, the ATWS Rule Guidance, and the Company's previous commitment. The proposed resolution will either be consistent with the Company's earlier commitment or an alternative, acceptable to the Staff, which meets the requirements of the ATWS Rule.
Carolina Power & Light Company is reviewing the existing design of the Brunswick ARI system against the requirements of ATWS Rule, the ATWS Rule Guidance, and the Company's previous commitment. The proposed resolution will either be consistent with the Company's earlier commitment or an alternative, acceptable to the Staff, which meets the requirements of the ATWS Rule.

Revision as of 20:27, 8 March 2021

Informs That Proposed Resolution Re ATWS Alternate Rod Injection Sys Design Will Be Consistent W/Util Commitment or NRC Approved Alternative
ML20247F285
Person / Time
Site: Brunswick  Duke Energy icon.png
Issue date: 09/07/1989
From: Cutter A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NLS-89-255, TAC-73351, TAC-73352, NUDOCS 8909180125
Download: ML20247F285 (1)


Text

I t

, Caronna Power & Light Company P.O. Box 1551

  • Ralery . N C. 27602 SEP 071989 A. 8 CUTTER SERIAL: NLS-89-255 Vice President 10 CFR 50.62 Nuclear Services Department United States Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, DC 20555 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-325 & 50-324/ LICENSE NOS. DPR-71 & DPR-62 ATWS ARI SYSTEM DESIGN (NRC TAC NOS. 73351/73352)

Gentlemen:

In a letter dated August 21, 1989, the NRC informed Carolina Power & Light Company (CP&L) of their conclusion that the "as-built" alternate rod injection (ARI) system at Brunswick is not in agreement with the ATWS Rule Guidance.

Specifically, the ARI system is not powered independently from the reactor trip system (RTS). The Company was requested to advise the Staff, within 15 days, of whether the guidance of the rule will be met for this system.

Carolina Power & Light Company is reviewing the existing design of the Brunswick ARI system against the requirements of ATWS Rule, the ATWS Rule Guidance, and the Company's previous commitment. The proposed resolution will either be consistent with the Company's earlier commitment or an alternative, acceptable to the Staff, which meets the requirements of the ATWS Rule.

A plan and schedule for resolution of this issue will be submitted by October 23, 1989.

Please refer any questions regarding this submittal to Mr. M. R. Oates at (919) 546-6063.

Yours very trul

/ / y-k l' IT A. B. Cutter cc: Mr. S. D. Ebneter Mr. W. H. Ruland Mr. E. G. Tourigny i

8909180125 890907 PDR ADOCK 05000324 P FDC