ML13077A389: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(9 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML13077A389
| number = ML13077A389
| issue date = 03/15/2013
| issue date = 03/15/2013
| title = San Onofre, Unit 2 - Response to Request for Additional Information (RAI 42) Regarding Confirmatory Action Letter Response
| title = Response to Request for Additional Information (RAI 42) Regarding Confirmatory Action Letter Response
| author name = St.Onge R J
| author name = St.Onge R
| author affiliation = Edison International Co, Southern California Edison Co
| author affiliation = Edison International Co, Southern California Edison Co
| addressee name =  
| addressee name =  
Line 13: Line 13:
| document type = Letter
| document type = Letter
| page count = 21
| page count = 21
| project = TAC:ME9727
| stage = Response to RAI
}}
}}
=Text=
{{#Wiki_filter:SOUTHERN CALIFORNIA                                                            Richard I. St. Onge EDISONI                EDISONDirector.                                                Nuclear Regulatory Affairs and Emergency Planning An EDISON INTERNATIONAL Company March 15,    2013 10 CFR 50.4 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
==Subject:==
Docket No. 50-361 Response to Request for Additional Information (RAI 42)
Regarding Confirmatory Action Letter Response (TAC No. ME 9727)
San Onofre Nuclear Generating Station, Unit 2
==References:==
: 1. Letter from Mr. Elmo E. Collins (USNRC) to Mr. Peter T. Dietrich (SCE), dated March 27, 2012, Confirmatory Action Letter 4-12-001, San Onofre Nuclear Generating Station, Units 2 and 3, Commitments to Address Steam Generator Tube Degradation
: 2. Letter from Mr. Peter T. Dietrich (SCE) to Mr. Elmo E. Collins (USNRC), dated October 3, 2012, Confirmatory Action Letter - Actions to Address Steam Generator Tube Degradation, San Onofre Nuclear Generating Station, Unit 2
: 3. Email from Mr. James R. Hall (USNRC) to Mr. Ryan Treadway (SCE), dated February 20, 2013, Request for Additional Information (RAIs 38-52) Regarding Response to Confirmatory Action Letter, San Onofre Nuclear Generating Station, Unit 2
==Dear Sir or Madam,==
On March 27, 2012, the Nuclear Regulatory Commission (NRC) issued a Confirmatory Action Letter (CAL) (Reference 1) to Southern California Edison (SCE) describing actions that the NRC and SCE agreed would be completed to address issues identified in the steam generator tubes of San Onofre Nuclear Generating Station (SONGS) Units 2 and 3. In a letter to the NRC dated October 3, 2012 (Reference 2), SCE reported completion of the Unit 2 CAL actions and included a Return to Service Report (RTSR) that provided details of their completion.
By email dated February 20, 2013 (Reference 3), the NRC issued Requests for Additional Information (RAI) regarding the CAL response. Enclosure 2 of this letter provides the response to RAI 42.
::63 (
P.O. Box 128 San Clemente, CA 92672
Document Control Desk                                            March 15, 2013 There are no new regulatory commitments contained in this letter. If you have any questions or require additional information, please call me at (949) 368-6240.
Sincerely,
==Enclosures:==
: 1. Response to RAI 42 cc:      E. E. Collins, Regional Administrator, NRC Region IV J. R. Hall, NRC Project Manager, SONGS Units 2 and 3 G. G. Warnick, NRC Senior Resident Inspector, SONGS Units 2 and 3 R. E. Lantz, Branch Chief, Division of Reactor Projects, NRC Region IV
ENCLOSURE 1 SOUTHERN CALIFORNIA EDISON RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING RESPONSE TO CONFIRMATORY ACTION LETTER DOCKET NO. 50-361 TAC NO. ME 9727 Response to RAI 42
===RAI 42===
In Reference 3, p. 4 (4 of 62), SCE does not conclusively state which screened tubes were actually plugged. Please discuss the threshold and implementation of the criteria (with exceptions) and provide or refer to a list of confirmed plugged tubes in Unit 2.
===RESPONSE===
Note: RAI Reference 3 is MHI Document L5-04GA571, "Screening Criteria for Susceptibility to In-Plane Tube Motion," Revision 6, dated October 3, 2012.
Conclusively state which screened tubes were plugged All tubes with an aggregate score at or above the threshold screening level were plugged. The Unit 2 steam generator (SG) tubes meeting the screening criteria from RAI Reference 3 are listed in Table 15, for SG 2E-089, and Table 16, for SG 2E-088.
Discuss the threshold and implementation of the criteria (with exceptions)
RAI Reference 3 identified nine screening criteria found to indicate susceptibility to tube-to-tube wear (TTW) from Unit 3 results:
: 1. COUNT - Number of wear indications at anti-vibration bar (AVB) intersections
: 2. HOT COUNT - Number of AVB wear indications on the hot leg side of U-bend
: 3. HIGH/LOW - Wear indications at AVB bars B01/B02 and B131/B12
: 4. CONTINUOUS -Number of consecutive AVB wear indications
: 5. TSP -Wear indications at upper tube support plate (TSP) intersections (TSP 5, 6 and 7)
: 6. LENGTH - Length of AVB wear scars as determined from bobbin coil inspection data
: 7. VOID - Average void fraction that the tube is exposed to in U-bend region
: 8. REGION - Distance to center of AVB wear area
: 9. COUPLING - Coupling effect between adjacent tubes (i.e., proximity to tubes that screen in for plugging)
Details of the nine screening criteria are described in RAI Reference 3, Section 3, "Proposed screening criteria based on Unit 3 results."
Weighting factors for each of the nine criteria were developed based on the proportion of Unit 3 tubes meeting the criteria that exhibited TTW. Individual thresholds were not set for each criterion. Instead, all nine weighting factors were aggregated to produce a combined, tube-specific TTW susceptibility score. Using the examination data from the 326 tubes found with TTW in Unit 3, a threshold screening level was established such that the combined TTW susceptibility scores of all tubes exhibiting TTW were above the threshold screening level. This assured that the false negative rate for the threshold screening level was zero.
The screening criteria were applied to tubes in both Unit 2 SGs, and 99 tubes in SG 2E-088 and 203 tubes in SG 2E-089 were identified with combined TTW susceptibility scores above the threshold screening level. Further validating the screening criteria approach, the 203 screened tubes in SG 2E-089 included both tubes in SG 2E-089 found with TTW (no tubes in SG 2E-088 were found with TTW).
Page 2 of 19
No exceptions were taken to the screening criteria. However, additional tubes were selected for preventative plugging based on recommendations from vendors and industry experts. Refer to Table 8-4 of the CAL Response, Enclosure 2, SONGS Unit 2 Return to Service Report.
Provide a list of confirmed plugged tubes in Unit 2 SONGS Nuclear Engineering Change Package (NECP) 800873488, Revision 0, Affected Section Change (ASC) D0062286, contains lists of the confirmed plugged tubes in Unit 2. The following pages provide the tube plugging lists excerpted from this NECP. The highlighted tubes were those recommended for plugging in RAI Reference 3, Tables 15 and 16.
Page 3 of 19
NECP Number            800873488 Rev 0            ASC No. D0062286                                Page _28_of U2NCP No800873486                                                  43  1 U2 NECP 800873488 RSG 2E-088 Tube Plugging/Stabilizing Lista Row      Col    Plug  Stab Typeb        Stab Length (in)                          Reason 112      88    Yes      Single                668                            35% TWD AVB 133      91    Yes      Single                668                            35% TWD AVB 124      48    Yes      Single                668                      47% TWD- Retainer Bar 125      49    Yes      Single                668                      54% TWD - Retainer Bar 120      92    Yes      Single                668                          Preventative -AVB 128      94    Yes      Single                668                          Preventative -AVB 121      81    Yes        Split              Note c                        Preventative - FSW 120      82    Yes        Split              Note c                        Preventative. FSW 105      83    Yes        Split              Note c                        Preventative - FSW 107      83    Yes        Split              Note c                        Preventative - FSW 104      84    Yes        Split              Note c                        Preventative - FSW 106      84    Yes        Split              Note c                        Preventative - FSW 108    84    Yes        Split              Note c                        Preventative - FSW 122    84      Yes      Split              Note c                        Preventative - FSW 97      85      Yes      Split              Note c                        Preventative - FSW 99      85      Yes      Split              Note c                        Preventative - FSW 103    85      Yes      Split              Note c                        Preventative - FSW 105    85      Yes      Split              Note c                        Preventative - FSW 107    85      Yes      Split              Note c                        Preventative - FSW 115    85      Yes      Split              Note c                        Preventative - FSW 121    85      Yes      Split              Note c                        Preventative - FSW 123    8S      Yes      Split              Note c                        Preventative - FSW 133    85      Yes      Split              Note c                        Preventative - FSW 98    86      Yes      Split              Note c                        Preventative - FSW 100    86      Yes      Split              Note c                          Preventative - FSW 102    86      Yes      Split              Note c                          Preventative - FSW 104    86      Yes      Split              Note c                          Preventative - FSW 106    86      Yes      Split              Note c                          Preventative - FSW 108    86      Yes      Split              Note c                          Preventative - FSW 112    86      Yes      Split              Note c                          Preventative - FSW 114    86      Yes      Split              Note c                          Preventative - FSW 116    86      Yes      Split              Note c                          Preventative - FSW 122    86      Yes      Split              Note c                          Preventative - FSW 124    86      Yes      Split              Note c                          Preventative - FSW a)    From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2- Steam Generators 88 & 89- 2012.-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 1 of 16 Page 4 of 19
NECP Number            800873488 Rev 0                                                            Page 29 of 43        1 U2NCP No800873486 U2 NECP 800873488 RSG 2E-088 Tube Plugging/Stabilizing Lista Row      Col    Plug  Stab Typeb      Stab Length (in)                          Reason 126      86    Yes      Split              Note c                        Preventative - FSW 101      87    Yes      Split              Note c                        Preventative - FSW 103      87    Yes      Split              Note c                        Preventative - FSW 105      87    Yes      Split              Note c                        Preventative - FSW 111      87    Yes      Split              Note c                        Preventative - FSW 113      87    Yes      Split              Note c                        Preventative - FSW 115      87    Yes      Split              Note c                        Preventative - FSW 121      87    Yes      Split              Note c                        Preventative - FSW 123      87      Yes      Split              Note c                        Preventative - FSW 125    87      Yes      Split              Note c                        Preventative - FSW 100    88      Yes      Split              Note c                        Preventative - FSW 102    88      Yes      Split              Note c                        Preventative - FSW 104    88      Yes      Split              Note c                        Preventative - FSW 106    88      Yes      Split              Note c                        Preventative - FSW 110    88      Yes      Split              Note C                        Preventative - FSW 114    88      Yes      Split              Note c                        Preventative - FSW 116    88      Yes      Split              Note c                        Preventative - FSW 118    88      Yes      Split              Note c                        Preventative - FSW 120    88      Yes      Split              Note c                        Preventative - FSW 122    88      Yes      Split              Note c                        Preventative - FSW 124    88      Yes      Split              Note c                        Preventative - FSW 95    89      Yes      Split              Note c                        Preventative - FSW 101    89      Yes      Split              Note c                        Preventative - FSW 103    89      Yes      Split              Note c                        Preventative - FSW 105    89      Yes      Split              Note c                        Preventative - FSW 107    89      Yes      Split              Note c                        Preventative - FSW 111    89      Yes      Split              Note c                        Preventative - FSW 113    89      Yes      Split              Note c                        Preventative - FSW 115    89      Yes      Split              Note c                        Preventative - FSW 117    89      Yes      Split              Note c                        Preventative - FSW 119    89      Yes      Split              Note c                        Preventative - FSW 121    89      Yes      Split              Note c                        Preventative - FSW 123    89      Yes      Split              Note c                        Preventative - FSW 127    89      Yes      Split              Note c                        Preventative - FSW a)    From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89- 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 2 of 16 Page 5 of 19
NECP Number            800873488 Rev 0            ASC No. D0062286                                Page _Mof List"                        43  1 800873488 U2 NECP U2  NECP    Tube 800873488 Plugging/Stabilizing 2E-088 RSG RSG 2E-088 Tube Plugging/Stabilizing List' Row      Col    Plug    Stab Typeb      Stab Length (in)                          Reason 94      90    Yes      Split              Note c                        Preventative - FSW 100      90    Yes      Split              Note c                        Preventative - FSW 102      90    Yes      Split              Note c                        Preventative - FSW 104      90    Yes      Split              Note c                        Preventative - FSW 106      90    Yes      Split              Note c                        Preventative - FSW 110      90    Yes      Split              Note c                        Preventative - FSW 112      90    Yes      Split              Note c                        Preventative - FSW 114      90    Yes        Split              Note c                        Preventative - FSW 116      90    Yes        Split              Note c                        Preventative - FSW 95      91    Yes        Split              Note c                        Preventative - FSW 101      91      Yes      Split              Note c                        Preventative - FSW 103      91      Yes      Split              Note c                        Preventative - FSW 105      91      Yes      Split              Note c                        Preventative  - FSW 107      91      Yes      Split              Note c                        Preventative  - FSW 109      91      Yes      Split              Note c                        Preventative  - FSW 111      91      Yes      Split              Note c                        Preventative  - FSW 113      91      Yes      Split              Note c                        Preventative - FSW 115      91      Yes      Split              Note c                        Preventative - FSW 117      91      Yes      Split              Note c                        Preventative - FSW 98      92      Yes      Split              Note c                        Preventative - FSW 100      92      Yes      Split              Note c                        Preventative - FSW 102      92      Yes      Split              Note c                        Preventative - FSW 104      92      Yes      Split              Note c                        Preventative - FSW 106      92      Yes      Split              Note c                        Preventative- FSW 108      92      Yes      Split              Note c                        Preventative - FSW 110      92      Yes      Split              Note c                        Preventative - FSW 112      92      Yes      Split              Note c                        Preventative - FSW 114      92      Yes      Split              Note c                        Preventative  - FSW 116      92      Yes      Split              Note c                        Preventative  - FSW 118      92      Yes      Split              Note c                        Preventative  - FSW 136      92    Yes      Split              Note c                        Preventative  - FSW 99      93    Yes      Split              Note c                        Preventative - FSW 101      93    Yes      Split              Note c                        Preventative - FSW 103      93    Yes      Split              Note c                        Preventative - FSW a)    From AREVA Steam Generator Eddy Current Final Report -San Onofre Nuclear Generating Station (SONGS) Unit 2- Steam Generators 88 & 89- 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 3 of 16 Page 6 of 19
NECP Number            800873488      Rev 0      ASC No. D0062286                                Page 31 of 43  1 U2 NECP 800873488 RSG 2E-088 Tube Plugging/Stabilizing                      Lista Row      Col    Plug    Stab Typeb      Stab Length (in)                          Reason 107      93      Yes        Split              Note c                        Preventative - FSW 111      93    Yes        Split              Note c                        Preventative - FSW 117      93    Yes        Split              Note c                        Preventative - FSW 129      93    Yes        Split              Note c                        Preventative - FSW 94      94    Yes        Split              Note c                        Preventative -FSW 4
135      93    Yes        Split              Note c                        Preventative - FSW 137      89    Yes        Split              Note c                        Preventative - FSWd 108      34    Yes      None                                          Preventative - Retainer Bar 110      34    Yes      Single              668                      Preventative - Retainer Bar 111      35    Yes        None                                        Preventative - Retainer Bar 109      35    Yes      Single              668                      Preventative - Retainer Bar 110      36    Yes        None                                        Preventative - Retainer Bar 112      36    Yes        None                                        Preventative - Retainer Bar 111      37    Yes        None                                        Preventative - Retainer Bar 113      37    Yes        None                                        Preventative - Retainer Bar 112      38    Yes        None                                        Preventative - Retainer Bar 114      38      Yes      None                                        Preventative - Retainer Bar 113      39      Yes      None                                        Preventative - Retainer Bar 11S      39      Yes      None                                        Preventative - Retainer Bar 114      40      Yes      None                                        Preventative - Retainer Bar 116      40      Yes      None                                        Preventative - Retainer Bar 115      41      Yes      None                                        Preventative - Retainer Bar 117      41      Yes      None                                        Preventative - Retainer Bar 116      42      Yes      None                                        Preventative - Retainer Bar 118      42      Yes      None                                        Preventative - Retainer Bar 117      43      Yes      None                                        Preventative - Retainer Bar 119      43      Yes      None                                        Preventative - Retainer Bar 118      44      Yes      None                                        Preventative - Retainer Bar 120      44      Yes      None                                        Preventative - Retainer Bar 119      45      Yes      None                  -                      Preventative - Retainer Bar 121      45      Yes      Single              668                    Preventative - Retainer Bar 122      46      Yes      None                  -                      Preventative - Retainer Bar 120    46      Yes      Single              668                      Preventative - Retainer Bar 121    47      Yes      None                                          Preventative - Retainer Bar a)    From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 4 of 16 Page 7 of 19
Klr-f*r I *1*;;;;%/r-Kl, uIm' 6%k
                  .V.-0A7A0
                            *rnnQ7'1A00    D0l n
                                              ,.VU.
ACt' ki    rnnC)')QC Page ag _322f4of 43      1 U2 NECP 800873488 RSG 2E-088 Tube Plugging/Stabilizing Lista Row        Col  Plug    Stab Typeb      Stab Length (in)                        Reason 123      47    Yes        None                                        Preventative - Retainer Bar 122      48    Yes        None                                        Preventative - Retainer Bar 123      49    Yes        None                                        Preventative - Retainer Bar 124      50    Yes        None                                        Preventative - Retainer Bar 126      50    Yes        None                                        Preventative - Retainer Bar 125      51    Yes        None                                        Preventative - Retainer Bar 127      51    Yes        None                                        Preventative - Retainer Bar 126      52    Yes        None                                        Preventative - Retainer Bar 128      52    Yes        None                                        Preventative - Retainer Bar 127      53    Yes        None                                        Preventative - Retainer Bar 129      53    Yes        None                                        Preventative - Retainer Bar 128        54  Yes        None                                        Preventative - Retainer Bar 130        54  Yes        None                                        Preventative - Retainer Bar 129        55  Yes        None                                        Preventative - Retainer Bar 131        55  Yes        None                                        Preventative - Retainer Bar 130      56    Yes        Single              668                      Preventative - Retainer Bar 132        56  Yes        Single              668                      Preventative - Retainer Bar 131        57    Yes      None                                        Preventative - Retainer Bar 131      121    Yes      None                -                      Preventative - Retainer Bar 130      122    Yes      Single              668                      Preventative - Retainer Bar 132      122    Yes      Single              668                      Preventative - Retainer Bar 129      123    Yes      None                -                      Preventative - Retainer Bar 131      123    Yes      None                                        Preventative - Retainer Bar 128      124    Yes      None                                        Preventative - Retainer Bar 130      124    Yes      None                                        Preventative - Retainer Bar 127      125    Yes      None                                        Preventative - Retainer Bar 129      125    Yes      None                                        Preventative - Retainer Bar 126      126    Yes      None                                        Preventative - Retainer Bar 128      126    Yes      None                                        Preventative - Retainer Bar 125      127    Yes      None                                        Preventative - Retainer Bar 127      127    Yes      None                                        Preventative - Retainer Bar 124      128    Yes      None                                        Preventative - Retainer Bar 126      128    Yes      None                                        Preventative - Retainer Bar 123      129    Yes      None                                        Preventative - Retainer Bar a)    From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilzer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)
Attachment 3                                                                                                  PAGE S of 16 Page 8 of 19
NECP Number            800873488 Rev 0            ASC No. D0062286                                Page 33 of 43    1 U2 NECP 800873488 LiSta RSG ZE-088 Tube Plugging/Stabilizing Row      Col    Plug  Stab Typeb        Stab Length (in)                          Reason 125      129    Yes      None                                          Preventative - Retainer Bar 122      130    Yes      None                                          Preventative - Retainer Bar 124    130    Yes      None                                          Preventative - Retainer Bar 121      131    Yes      None                                          Preventative - Retainer Bar 123    131    Yes      None                                          Preventative - Retainer Bar 122      132    Yes      None                  -                      Preventative - Retainer Bar 120    132    Yes      Single              668                      Preventative - Retainer Bar 119    133    Yes      None                  -                      Preventative - Retainer Bar 121    133    Yes      Single              668                      Preventative - Retainer Bar 118    134    Yes      None                  -                      Preventative - Retainer Bar 120    134    Yes      None                                          Preventative - Retainer Bar 117    135    Yes      None                                          Preventative - Retainer Bar 119    135    Yes      None                                          Preventative - Retainer Bar 116    136    Yes      None                                          Preventative - Retainer Bar 118    136    Yes      None                                          Preventative - Retainer Bar 115    137    Yes      None                                          Preventative - Retainer Bar 117    137    Yes      None                                          Preventative - Retainer Bar 114    138    Yes      None                                          Preventative  - Retainer  Bar 116    138    Yes      None                                          Preventative  - Retainer  Bar 113    139    Yes      None                                          Preventative  - Retainer  Bar 115    139    Yes      None                                          Preventative  - Retainer  Bar 112    140    Yes      None                                          Preventative - Retainer Bar 114    140    Yes      None                                          Preventative - Retainer Bar 111    141    Yes      None                                          Preventative - Retainer Bar 113    141    Yes      None                                          Preventative - Retainer Bar 110    142    Yes      None                                          Preventative - Retainer Bar 112    142    Yes      None                                          Preventative - Retainer Bar 111    143    Yes      None                  -                      Preventative - Retainer Bar 109    143    Yes      Single                668                    Preventative - Retainer Bar 108    144    Yes      None                  -                      Preventative - Retainer Bar 110    144    Yes      Single                668                    Preventative - Retainer Bar 98      84    Yes      Split              Note c                    Wear at 6 Continuous AVBs 88      88    Yes      Split              Note c                    Wear at 6 Continuous AVBs 97      89    Yes      Split              Note c                    Wear at 6 Continuous AVBs a)    From AREVA Steam Generator Eddy Current Final Report -San Onofre Nuclear Generating Station (SONGS) Unit 2- Steam Generators 88 & 89- 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 6 of 16 Page 9 of 19
NECP Number          800873488      Rev 0        ASC No- D0062286                                Page 34 of 43    1 U2 NECP 800873488 RSG 2E-088 Tube Plugging/Stabilizing Lista Row    Col    Plug  Stab Typeb        Stab Length (in)                          Reason 108    90    Yes        Split              Note c                    Wear at 6 Continuous AVBs 124    92      Yes      Split              Note c                    Wear at 6 Continuous AVBs 134    94      Yes      Split              Note c                    Wear at 6 Continuous AVBs a)  From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 7 of 16 Page 10 of 19
NECP Number          800873488 Rev 0            ASC No. D0062286                                  Page 35 of 43  1 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row      Col    Plug  Stab Typeb        Stab Length (in)                          Reason 111      81    Yes        Split              Note c                  14% TWD- FSW (Preventative) 113      81    Yes        Split              Note c                  14% TWD- FSW (Preventative) 127    127    Yes      Single                668                        38% TWD - Retainer Bar 119    133    Yes      Single                668                        90% TWD - Retainer Bar 103      77    Yes        Split              Note c                        Preventative - FSW 109      77    Yes        Split              Note c                        Preventative - FSW 111      77    Yes        Split              Note c                        Preventative - FSW 100      78    Yes        Split              Note c                        Preventative - FSW 102      78    Yes        Split              Note c                        Preventative - FSW 104      78    Yes        Split              Note c                        Preventative - FSW 108      78    Yes        Split              Note c                        Preventative - FSW 110      78    Yes        Split              Note c                        Preventative - FSW 112      78    Yes        Split              Note c                        Preventative - FSW 97      79    Yes        Split              Note c                        Preventative - FSW 99      79    Yes        Split              Note c                        Preventative - FSW 101      79    Yes        Split              Note c                        Preventative - FSW 112      79    Yes        Split              Note c                        Preventative - FSW 92      80    Yes        Split              Note c                          Preventative - FSW 94      80    Yes        Split              Note c                          Preventative - FSW 96      80    Yes        Split              Note c                          Preventative - FSW 98      80    Yes        Split              Note c                          Preventative - FSW 100      80    Yes        Split              Note c                          Preventative - FSW 102      80    Yes        Split              Note c                          Preventative - FSW 110      80    Yes        Split              Note c                          Preventatve - FSW 112      80    Yes        Split              Note c                          Preventative - FSW 114      80    Yes        Split              Note c                          Preventative - FSW 91      81    Yes        Split              Note c                          Preventative - FSW 93      81    Yes        Split              Note c                          Preventative - FSW 9S      81    Yes        Split              Note c                          Preventative - FSW 97      81    Yes        Spilt              Note c                          Preventative - FSW 99      81    Yes        Split              Note c                          Preventative - FSW 101      81    Yes        Split              Note c                          Preventative - FSW 1U3      81    Yes        Split              Note c                          Preventative - FSW 106      81    Yes        Split              Note c                          Preventative - FSW 107      81    Yes        Split              Note c                          Preventative - FSW a)  From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 -Steam Generators 88 & 89-2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabiizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 8 of 16 Page 11 of 19
Klal*¢' m r'4i*.
I k,,k UM~'f  V1..k,.
o/1nn OAO'O 7"1A00    13-eA DU.
A0i'M      nma'31)012 Page Pg 366 off4 43      1 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Lista Row      Col      Plug    Stab Typeb      Stab Length (in)                        Reason 109        81      Yes        Split              Note c                      Preventative - FSW 115        81      Yes        Split              Note c                      Preventative - FSW 117        81      Yes        Split              Note c                      Preventative - FSW 119        81      Yes        Split              Note c                      Preventative - FSW 121        81      Yes        Split            Note c                      Preventative - FSW 90        82      Yes        Split              Note c                      Preventative - FSW 92        82      Yes        Split              Note c                      Preventative - FSW 94        82      Yes        Split              Note c                      Preventative - FSW 96        82      Yes        Split              Note c                      Preventative - FSW 98        82      Yes        Split              Note c                      Preventative - FSW 100        82      Yes        Split            Note c                      Preventative - FSW 102        82      Yes        Split            Note c                      Preventative - FSW 104        82      Yes        Split            Note c                      Preventative - FSW 106        82      Yes        Split              Note c                      Preventative - FSW 108        82      Yes        Split              Note c                        Preventative - FSW 110        82      Yes        Split            Note c                        Preventative - FSW 112        82      Yes        Split              Note c                        Preventative - FSW 114        82      Yes        Split            Note c                        Preventative - FSW 116        82      Yes        Split            Note c                        Preventative - FSW 118        82      Yes        Split            Note c                        Preventative - FSW 120        82      Yes        Split            Note c                        Preventative - FSW 122        82      Yes        Split            Note c                        Preventative - FSW 91        83      Yes        Split            Note c                        Preventative - FSW 93        83      Yes        Split            Note c                        Preventative - FSW 95        83      Yes        Split            Note c                        Preventative  - FSW 97        83      Yes        Split            Note c                        Preventative  - FSW 99        83      Yes        Split            Note c                        Preventative  - FSW 101        83      Yes        Split            Note c                        Preventative  - FSW 103        83      Yes        Split            Note c                        Preventative - FSW 105        83      Yes        Split            Note c                        Preventative - FSW 107        83      Yes        Split            Note c                        Preventative - FSW 109        83      Yes        Split            Note c                        Preventative - FSW 11        83      Yes        Split            Note c                        Preventative - FSW 113        83      Yes        Split            Note c                        Preventative - FSW S115 83          Yes        Split            Notec                        Preventative - FSW a)  From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2- Steam Generators 88 & 89- 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)
Attachment 3                                                                                                PAGE 9 of 16 Page 12 of 19
NECP Number          800873488 Rev 0            ASC No. D0062286                                  Page 37 of 43        1 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row      Col    Plug    Stab Typeb        Stab Length (in)                          Reason 117      83    Yes        Split              Note c                        Preventative - FSW 119      83    Yes        Split              Note c                        Preventatve - FSW 121      83    Yes        Split              Note c                          Preventative - FSW 90      84    Yes        Split              Note c                          Preventative - FSW 92      84    Yes        Split              Note c                          Preventative - FSW 94      84    Yes        Split              Note c                          Preventative - FSW 96      84    Yes        Split              Note c                          Preventative - FSW 98      84    Yes        Split              Note c                          Preventative - FSW 100      84    Yes        Split              Note c                          Preventative - FSW 102      84    Yes        Split              Note c                          Preventative - FSW 104      84    Yes        Split              Note c                          Preventatlve - FSW 106      84    Yes        Split              Note c                          Preventative - FSW 106      84    Yes        Split              Note c                          Preventative - FSW 110      84    Yes        Split              Note c                          Preventative - FSW 112      84    Yes        Split              Note c                          Preventative - FSW 114      84    Yes        Split              Note c                          Preventative - FSW 116      84    Yes        Split              Note c                          Preventative - FSW 118      84    Yes        Split              Note c                          Preventative - FSW 120      84    Yes        Split              Note c                          Preventative - FSW 126      84    Yes        Split              Note c                          Preventative - FSW 128      84    Yes        Split              Note c                          Preventative - FSW 132      84    Yes        Split              Note c                          Preventative - FSW 91      85    Yes        Split              Note c                          Preventative  - FSW 93      85    Yes        Split              Note c                          Preventative  - FSW 95      85    Yes        Split              Note c                          Preventative  - FSW 97      85    Yes        Split              Note c                          Preventativ  - FSW 99      85    Yes        Split              Note c                          Preventative - FSW 101      85    Yes        Split              Note c                          Preventative - FSW 103      85    Yes        Split              Note c                          Preventative - FSW 105      85    Yes        Split              Note c                          Preventative - FSW 107      85    Yes        Split              Note c                          Preventative - FSW 109      85    Yes        Split              Note c                          Preventative - FSW 1U      85    Yes        Split              Note c                          Preventative - FSW 113    85    Yes        Split              Note c                          Preventative - FSW 115    85    Yes        Split              Note c                          Preventative - FSW a)  From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Stea m Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 10 of 16 Page 13 of 19
NECP Number            800873488 Rev 0            ASC No. D0062286                                  Page 38 of 43 1
U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Lista Row      Col    Plug    Stab Typeb        Stab Length (in)                            Reason 117      85    Yes        Split              Note c                          Preventative - FSW 119      85    Yes        Split              Note c                          Preventative - FSW 121      85    Yes        Split              Note c                          Preventative - FSW 127      85    Yes        Split              Note c                          Preventative - FSW 88      86    Yes        Split              Note c                          Preventative - FSW 92      86    Yes        Split              Note c                          Preventative - FSW 94      86    Yes        Split              Note c                          Preventative - FSW 96      86    Yes        Split              Note c                          Preventative - FSW 98      86    Yes        Split              Note c                          Preventative - FSW 100      86    Yes        Split              Note c                          Preventative  - FSW 102      86    Yes        Split              Note c                          Preventative  - FSW 104      86    Yes        Split              Note c                          Preventative  - FSW 106      86    Yes        Split              Note c                          Preventative  - FSW 108      86    Yes        Split              Note c                          Preventative - FSW 110      86    Yes        Split              Note c                          Preventative - FSW 112      86    Yes        Split              Note c                          Preventative - FSW 114      86    Yes        Split              Note c                          Preventative - FSW 116      86    Yes        Split              Note c                          Preventative - FSW 118      86    Yes        Split              Note c                          Preventative - FSW 122      86    Yes        Split              Note c                          Preventative - FSW 130      86    Yes        Split              Note c                          Preventative - FSW 93      87    Yes        Split              Note c                          Preventative - FSW 95      87    Yes        Split              Note c                          Preventative - FSW 97      87    Yes        Split              Note c                          Preventative - FSW 99      87    Yes        Split              Note c                          Preventative - FSW 101      87    Yes        Split              Note c                          Preventative - FSW 103      87    Yes        Split              Note c                          Preventative - FSW 105      87    Yes        Split              Note c                          Preventative - FSW 107      87    Yes        Split              Note c                          Preventative - FSW 109      87    Yes        Split              Note c                          Preventative - FSW 111      87    Yes        Split              Note c                          Preventative - FSW 113      87    Yes        Split              Note c                          Preventative - FSW 115      87    Yes        Split              Note c                          Preventative - FSW 117      87    Yes        Split              Note c                          Preventative - FSW 119      87    Yes        Split              Note c                          Preventative - FSW a)  From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 -Steam Generators 88 & 89- 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 11 of 16 Page 14 of 19
NECP Number            800873488 Rev 0            ASC No. D0062286                                Page 39 of 43        1 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row      Col    Plug    Stab Typeb        Stab Length (in)                            Reason 129      87    Yes        Split              Note c                          Preventative - FSW 94      88    Yes        Split              Note c                          Preventative - FSW 96      88    Yes        Split              Note c                          Preventative - FSW 98      88    Yes        Split              Note c                          Preventative - FSW 100      88    Yes        Split              Note c                          Preventative - FSW 102      88    Yes        Split              Note c                          Preventative - FSW 104      88    Yes        Split              Note c                          Preventative - FSW 106      88    Yes        Split              Note c                          Preventative - FSW 10      88    Yes        Split              Note c                          Preventative - FSW 110      88    Yes        Split              Note c                          Preventative- FSW 112      88    Yes        Split              Note c                          Preventative - FSW 114      88    Yes        Split              Note c                          Preventative - FSW 116      88    Yes        Split              Note c                          Preventative - FSW 118      88    Yes        Split              Note c                          Preventative - FSW 138      88    Yes        Split              Note c                          Preventative - FSW 95      89    Yes        Split              Note c                          Preventative - FSW 97      89    Yes        Split              Note c                          Preventative - FSW 99      89    Yes        Split              Note c                          Preventative - FSW 101      89    Yes        Split              Note c                          Preventative - FSW 103      89    Yes        Split              Note c                          Preventatlve - FSW 105      89    Yes        Split              Note c                          Preventative - FSW 107      89    Yes        Split              Note c                          Preventative - FSW 109      89    Yes        Split              Note c                          Preventative - FSW 111      89    Yes        Split              Note c                          Preventative - FSW 113      89    Yes        Split              Note c                          Preventative - FSW 115      89    Yes        Split              Note c                          Preventative - FSW 117      89    Yes        Split              Note c                          Preventative - FSW 131      89    Yes        Split              Note c                          Preventative - FSW 100      90    Yes        split              Note c                          Preventative - FSW 102      90    Yes        Split              Note c                          Preventative - FSW 104      90    Yes        Split              Note c                          Preventative - FSW 106      90    Yes        Split              Note c                          Preventative - FSW 108      90    Yes        Split              Note c                          Preventative - FSW 110      90    Yes        Split              Note c                          Preventative - FSW 112      90    Yes        Split              Note c                          Preventative - FSW a)  From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 12 of 16 Page 15 of 19
NECP Number          800873488 Rev 0              ASC No. D0062286                                Page 40 of 43 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row      Col    Plug  Stab Type?        Stab Length (in)                            Reason 114      90    Yes        Split              Note c                          Preventative - FSW 116      90    Yes        Split              Note c                          Preventative - FSW 118      90    Yes        Split              Note c                          Preventative - FSW 130      90    Yes        Split              Note c                          Preventative - FSW 132      90    Yes        Split              Note c                          Preventative - FSW 134      90    Yes        Split              Note c                          Preventative - FSW 99      91    Yes        Split              Note c                          Preventative - FSW 105      91    Yes        Split              Note c                          Preventative - FSW 107      91    Yes        Split              Note c                          Preventative - FSW 109      91    Yes        Split              Note c                          Preventative  - FSW 113      91    Yes        Split              Note c                          Preventative  - FSW 115      91    Yes        Split              Note c                          Preventative  - FSW 117      91    Yes        Split              Note c                          Preventative  - FSW 123      91    Yes        Split              Note c                          Preventative - FSW 98      92    Yes        Split              Note c                          Preventative - FSW 104      92    Yes        Split              Note c                          Preventative - FSW 108      92    Yes        Split              Note c                          Preventative - FSW 114      92    Yes        Split              Note c                          Preventative- FSW 116      92    Yes        Split              Note c                          Preventative - FSW 103      93    Yes        Split              Note c                          Preventative - FSW 115      93    Yes        Split              Note c                          Preventative - FSW 102      94    Yes        Split              Note c                          Preventative - FSW 114      94    Yes        Split              Note c                          Preventative - FSW 116      94    Yes        Split              Note c                          Preventative - FSW 103      95    Yes        Split              Note c                          Preventative - FSW 105      95    Yes        Split              Note c                          Preventative - FSW 107      95    Yes        Split              Note c                          Preventative - FSW 109      95    Yes        Split              Note c                          Preventative - FSW 115    95    Yes        Split              Note c                          Preventative - FSW 109    97    Yes        Split              Note c                          Preventative - FSW 110    98    Yes        Split              Note c                          Preventative - FSW 112    98    Yes        Split              Note c                          Preventative - FSW 80      68    Yes        Split              Note c                        Preventative - FSWd 104    72    Yes        Split              Nate c                        Preventative - FSWd 132    94    Yes        Split              Note c                        Preventative - FSWd a)  From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 -Steam Generators 88 &89 -2012-UJ2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabiizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 13 of 16 Page 16 of 19
NECP Number            800873488 Rev 0            ASC No. D0062286                                Page 41 of 43        /
U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row      Col    Plug    Stab Typeb        Stab Length (in)                          Reason 108    34      Yes      None                    -                      Preventative - Retainer Bar 110      34    Yes      Single                668                      Preventative - Retainer Bar 111      35    Yes        None                    -                      Preventative - Retainer Bar 109      35    Yes      Single                668                      Preventative - Retainer Bar 110      36    Yes        None                  -                      Preventative - Retainer Bar 112      36    Yes      None                                            Preventative - Retainer Bar 111      37    Yes      None                                            Preventative - Retainer Bar 113      37    Yes        None                                          Preventative - Retainer Bar 112      38    Yes        None                                          Preventative - Retainer Bar 114      38    Yes        None                                          Preventative - Retainer Bar 113      39    Yes        None                                          Preventative - Retainer Bar 115      39    Yes        None                                          Preventative - Retainer Bar 114      40    Yes        None                                          Preventative - Retainer Bar 116      40    Yes        None                                          Preventative - Retainer Bar 115      41    Yes        None                                          Preventative - Retainer Bar 117      41    Yes        None                                          Preventative - Retainer Bar 116      42    Yes        None                                          Preventative - Retainer Bar 118      42    Yes        None                                          Preventative - Retainer Bar 117      43    Yes        None                                          Preventative - Retainer Bar 119      43    Yes        None                                          Preventative - Retainer Bar 120      44    Yes        None                    -                      Preventative - Retainer Bar 118      44    Yes      Single                668                      Preventative - Retainer Bar 119      45    Yes        None                    -                      Preventative - Retainer Bar 121      4S    Yes      Single                668                      Preventative - Retainer Bar 122      46    Yes        None                    -                      Preventative - Retainer Bar 120      46    Yes      Single                668                      Preventative - Retainer Bar 121      47    Yes        None                    -                      Preventative - Retainer Bar 123      47    Yes        None                                          Preventative - Retainer Bar 122      48    Yes        None                                          Preventative - Retainer Bar 124      48      Yes      None                                          Preventative - Retainer Bar 123      49      Yes      None                                          Preventative - Retainer Bar 125      49      Yes      None                                          Preventative - Retainer Bar 124      50      Yes      None                                          Preventative - Retainer Bar 126      50      Yes      None                                          Preventative - Retainer Bar 125      51      Yes      None                                          Preventative - Retainer Bar a)  From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 14 of 16 Page 17 of 19
NECP Number            800873488 Rev 0            ASC No. D0062286                                Page 42 of 43        1 ASC No D0062286 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row      Col    Plug    Stab Typeb        Stab Length (in)                          Reason 127      51    Yes        None                                          Preventative - Retainer    Bar 126      52    Yes        None                                          Preventative - Retainer    Bar 128      52    Yes        None                                          Preventative - Retainer    Bar 127      53    Yes        None                                          Preventative - Retainer    Bar 129      53    Yes        None                                          Preventative - Retainer Bar 128      54    Yes        None                                          Preventative - Retainer Bar 130      54    Yes        None                                          Preventative - Retainer Bar 129      55    Yes        None                                          Preventative - Retainer Bar 131      55    Yes        None                  -                      Preventative - Retainer Bar 130      56    Yes      Single                668                      Preventative - Retainer Bar 132      56    Yes      Single                668                      Preventative  - Retainer Bar 131      57    Yes        None                                          Preventative  - Retainer  Bar 131    121    Yes        None                  -                      Preventative  - Retainer Bar 130    122    Yes      Single                668                      Preventative  - Retainer Bar 132    122    Yes      Single                668                      Preventative - Retainer Bar 129    123    Yes        None                  -                      Preventative - Retainer Bar 131    123    Yes        None                                          Preventative - Retainer Bar 128    124    Yes        None                                          Preventative - Retainer Bar 130    124    Yes        None                                          Preventative - Retainer Bar 127    125    Yes        None                                          Preventative - Retainer Bar 129    125    Yes        None                                          Preventative - Retainer Bar 126    126    Yes        None                                          Preventative - Retainer Bar 128    126    Yes        None                                          Preventative - Retainer Bar 125    127    Yes        None                                          Preventative - Retainer Bar 124    128    Yes        None                                          Preventative - Retainer Bar 126    128    Yes        None                                          Preventative - Retainer Bar 123    129    Yes        None                                          Preventative - Retainer Bar 125    129      Yes      None                                          Preventative - Retainer Bar 122    130    Yes        None                                          Preventative - Retainer Bar 124    130      Yes      None                                          Preventative - Retainer Bar 121    131      Yes      None                                          Preventative - Retainer Bar 123    131      Yes      None                                          Preventative - Retainer Bar 122    132      Yes      None                    -                    Preventative - Retainer Bar 120    132      Yes      Single              668                      Preventative - Retainer Bar 121    133      Yes      Single              668                      Preventative - Retainer Bar a)  From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 15 of 16 Page 18 of 19
NECP Number          800873488 Rev 0              ASC No. D0062286                                Page 43 of 43        1 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row      Col    Plug    StabTypeb        Stab Length (in)                            Reason 118    134    Yes        None                                          Preventative - Retainer Bar 120    134    Yes        None                                          Preventative - Retainer Bar 117    135    Yes        None                                          Preventative - Retainer Bar 119    135    Yes        None                                          Preventative - Retainer Bar 116    136    Yes        None                                          Preventative - Retainer Bar 118    136    Yes        None                                          Preventative - Retainer Bar 115    137    Yes        None                                          Preventative - Retainer Bar 117    137    Yes        None                                          Preventative - Retainer Bar 114    138    Yes        None                                          Preventative - Retainer Bar 116    138    Yes        None                                          Preventative - Retainer Bar 113    139    Yes        None                                          Preventative - Retainer Bar 115    139    Yes        None                                          Preventative - Retainer Bar 112    140    Yes        None                                          Preventative - Retainer Bar 114    140    Yes        None                                          Preventative - Retainer Bar 111    141    Yes        None                                          Preventative - Retainer Bar 113    141    Yes        None                                          Preventative - Retainer Bar 110    142    Yes        None                                          Preventative - Retainer Bar 112    142    Yes        None                                          Preventative - Retainer Bar 111    143    Yes        None                  -                      Preventative - Retainer Bar 109    143    Yes      Single                668                      Preventative - Retainer Bar 108    144    Yes        None                                          Preventative - Retainer Bar 110    144    Yes      Single                668                      Preventative - Retainer Bar 98      76    Yes        Split              Note c                    Wear at 6 Continuous AVBs 87      79    Yes        Split              Note c                    Wear at 6 Continuous AVBs 89      83    Yes        Split              Note c                    Wear at 6 Continuous AVBs 122      84    Yes        Split              Note c                    Wear at 6 Continuous AVys 121      89    Yes        Split              Note c                    Wear at 6 Continuous AVBs 120      90    Yes        Split              Note c                    Wear at 6 Continuous AVBs a)  From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 -Steam Generators 88 & 89-2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)                                                                                                PAGE 16 of 16 Page 19 of 19}}

Latest revision as of 21:38, 4 November 2019

Response to Request for Additional Information (RAI 42) Regarding Confirmatory Action Letter Response
ML13077A389
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 03/15/2013
From: St.Onge R
Edison International Co, Southern California Edison Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
TAC ME9727
Download: ML13077A389 (21)


Text

SOUTHERN CALIFORNIA Richard I. St. Onge EDISONI EDISONDirector. Nuclear Regulatory Affairs and Emergency Planning An EDISON INTERNATIONAL Company March 15, 2013 10 CFR 50.4 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Subject:

Docket No. 50-361 Response to Request for Additional Information (RAI 42)

Regarding Confirmatory Action Letter Response (TAC No. ME 9727)

San Onofre Nuclear Generating Station, Unit 2

References:

1. Letter from Mr. Elmo E. Collins (USNRC) to Mr. Peter T. Dietrich (SCE), dated March 27, 2012, Confirmatory Action Letter 4-12-001, San Onofre Nuclear Generating Station, Units 2 and 3, Commitments to Address Steam Generator Tube Degradation
2. Letter from Mr. Peter T. Dietrich (SCE) to Mr. Elmo E. Collins (USNRC), dated October 3, 2012, Confirmatory Action Letter - Actions to Address Steam Generator Tube Degradation, San Onofre Nuclear Generating Station, Unit 2
3. Email from Mr. James R. Hall (USNRC) to Mr. Ryan Treadway (SCE), dated February 20, 2013, Request for Additional Information (RAIs 38-52) Regarding Response to Confirmatory Action Letter, San Onofre Nuclear Generating Station, Unit 2

Dear Sir or Madam,

On March 27, 2012, the Nuclear Regulatory Commission (NRC) issued a Confirmatory Action Letter (CAL) (Reference 1) to Southern California Edison (SCE) describing actions that the NRC and SCE agreed would be completed to address issues identified in the steam generator tubes of San Onofre Nuclear Generating Station (SONGS) Units 2 and 3. In a letter to the NRC dated October 3, 2012 (Reference 2), SCE reported completion of the Unit 2 CAL actions and included a Return to Service Report (RTSR) that provided details of their completion.

By email dated February 20, 2013 (Reference 3), the NRC issued Requests for Additional Information (RAI) regarding the CAL response. Enclosure 2 of this letter provides the response to RAI 42.

63 (

P.O. Box 128 San Clemente, CA 92672

Document Control Desk March 15, 2013 There are no new regulatory commitments contained in this letter. If you have any questions or require additional information, please call me at (949) 368-6240.

Sincerely,

Enclosures:

1. Response to RAI 42 cc: E. E. Collins, Regional Administrator, NRC Region IV J. R. Hall, NRC Project Manager, SONGS Units 2 and 3 G. G. Warnick, NRC Senior Resident Inspector, SONGS Units 2 and 3 R. E. Lantz, Branch Chief, Division of Reactor Projects, NRC Region IV

ENCLOSURE 1 SOUTHERN CALIFORNIA EDISON RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING RESPONSE TO CONFIRMATORY ACTION LETTER DOCKET NO. 50-361 TAC NO. ME 9727 Response to RAI 42

RAI 42

In Reference 3, p. 4 (4 of 62), SCE does not conclusively state which screened tubes were actually plugged. Please discuss the threshold and implementation of the criteria (with exceptions) and provide or refer to a list of confirmed plugged tubes in Unit 2.

RESPONSE

Note: RAI Reference 3 is MHI Document L5-04GA571, "Screening Criteria for Susceptibility to In-Plane Tube Motion," Revision 6, dated October 3, 2012.

Conclusively state which screened tubes were plugged All tubes with an aggregate score at or above the threshold screening level were plugged. The Unit 2 steam generator (SG) tubes meeting the screening criteria from RAI Reference 3 are listed in Table 15, for SG 2E-089, and Table 16, for SG 2E-088.

Discuss the threshold and implementation of the criteria (with exceptions)

RAI Reference 3 identified nine screening criteria found to indicate susceptibility to tube-to-tube wear (TTW) from Unit 3 results:

1. COUNT - Number of wear indications at anti-vibration bar (AVB) intersections
2. HOT COUNT - Number of AVB wear indications on the hot leg side of U-bend
3. HIGH/LOW - Wear indications at AVB bars B01/B02 and B131/B12
4. CONTINUOUS -Number of consecutive AVB wear indications
5. TSP -Wear indications at upper tube support plate (TSP) intersections (TSP 5, 6 and 7)
6. LENGTH - Length of AVB wear scars as determined from bobbin coil inspection data
7. VOID - Average void fraction that the tube is exposed to in U-bend region
8. REGION - Distance to center of AVB wear area
9. COUPLING - Coupling effect between adjacent tubes (i.e., proximity to tubes that screen in for plugging)

Details of the nine screening criteria are described in RAI Reference 3, Section 3, "Proposed screening criteria based on Unit 3 results."

Weighting factors for each of the nine criteria were developed based on the proportion of Unit 3 tubes meeting the criteria that exhibited TTW. Individual thresholds were not set for each criterion. Instead, all nine weighting factors were aggregated to produce a combined, tube-specific TTW susceptibility score. Using the examination data from the 326 tubes found with TTW in Unit 3, a threshold screening level was established such that the combined TTW susceptibility scores of all tubes exhibiting TTW were above the threshold screening level. This assured that the false negative rate for the threshold screening level was zero.

The screening criteria were applied to tubes in both Unit 2 SGs, and 99 tubes in SG 2E-088 and 203 tubes in SG 2E-089 were identified with combined TTW susceptibility scores above the threshold screening level. Further validating the screening criteria approach, the 203 screened tubes in SG 2E-089 included both tubes in SG 2E-089 found with TTW (no tubes in SG 2E-088 were found with TTW).

Page 2 of 19

No exceptions were taken to the screening criteria. However, additional tubes were selected for preventative plugging based on recommendations from vendors and industry experts. Refer to Table 8-4 of the CAL Response, Enclosure 2, SONGS Unit 2 Return to Service Report.

Provide a list of confirmed plugged tubes in Unit 2 SONGS Nuclear Engineering Change Package (NECP) 800873488, Revision 0, Affected Section Change (ASC) D0062286, contains lists of the confirmed plugged tubes in Unit 2. The following pages provide the tube plugging lists excerpted from this NECP. The highlighted tubes were those recommended for plugging in RAI Reference 3, Tables 15 and 16.

Page 3 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page _28_of U2NCP No800873486 43 1 U2 NECP 800873488 RSG 2E-088 Tube Plugging/Stabilizing Lista Row Col Plug Stab Typeb Stab Length (in) Reason 112 88 Yes Single 668 35% TWD AVB 133 91 Yes Single 668 35% TWD AVB 124 48 Yes Single 668 47% TWD- Retainer Bar 125 49 Yes Single 668 54% TWD - Retainer Bar 120 92 Yes Single 668 Preventative -AVB 128 94 Yes Single 668 Preventative -AVB 121 81 Yes Split Note c Preventative - FSW 120 82 Yes Split Note c Preventative. FSW 105 83 Yes Split Note c Preventative - FSW 107 83 Yes Split Note c Preventative - FSW 104 84 Yes Split Note c Preventative - FSW 106 84 Yes Split Note c Preventative - FSW 108 84 Yes Split Note c Preventative - FSW 122 84 Yes Split Note c Preventative - FSW 97 85 Yes Split Note c Preventative - FSW 99 85 Yes Split Note c Preventative - FSW 103 85 Yes Split Note c Preventative - FSW 105 85 Yes Split Note c Preventative - FSW 107 85 Yes Split Note c Preventative - FSW 115 85 Yes Split Note c Preventative - FSW 121 85 Yes Split Note c Preventative - FSW 123 8S Yes Split Note c Preventative - FSW 133 85 Yes Split Note c Preventative - FSW 98 86 Yes Split Note c Preventative - FSW 100 86 Yes Split Note c Preventative - FSW 102 86 Yes Split Note c Preventative - FSW 104 86 Yes Split Note c Preventative - FSW 106 86 Yes Split Note c Preventative - FSW 108 86 Yes Split Note c Preventative - FSW 112 86 Yes Split Note c Preventative - FSW 114 86 Yes Split Note c Preventative - FSW 116 86 Yes Split Note c Preventative - FSW 122 86 Yes Split Note c Preventative - FSW 124 86 Yes Split Note c Preventative - FSW a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2- Steam Generators 88 & 89- 2012.-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 1 of 16 Page 4 of 19

NECP Number 800873488 Rev 0 Page 29 of 43 1 U2NCP No800873486 U2 NECP 800873488 RSG 2E-088 Tube Plugging/Stabilizing Lista Row Col Plug Stab Typeb Stab Length (in) Reason 126 86 Yes Split Note c Preventative - FSW 101 87 Yes Split Note c Preventative - FSW 103 87 Yes Split Note c Preventative - FSW 105 87 Yes Split Note c Preventative - FSW 111 87 Yes Split Note c Preventative - FSW 113 87 Yes Split Note c Preventative - FSW 115 87 Yes Split Note c Preventative - FSW 121 87 Yes Split Note c Preventative - FSW 123 87 Yes Split Note c Preventative - FSW 125 87 Yes Split Note c Preventative - FSW 100 88 Yes Split Note c Preventative - FSW 102 88 Yes Split Note c Preventative - FSW 104 88 Yes Split Note c Preventative - FSW 106 88 Yes Split Note c Preventative - FSW 110 88 Yes Split Note C Preventative - FSW 114 88 Yes Split Note c Preventative - FSW 116 88 Yes Split Note c Preventative - FSW 118 88 Yes Split Note c Preventative - FSW 120 88 Yes Split Note c Preventative - FSW 122 88 Yes Split Note c Preventative - FSW 124 88 Yes Split Note c Preventative - FSW 95 89 Yes Split Note c Preventative - FSW 101 89 Yes Split Note c Preventative - FSW 103 89 Yes Split Note c Preventative - FSW 105 89 Yes Split Note c Preventative - FSW 107 89 Yes Split Note c Preventative - FSW 111 89 Yes Split Note c Preventative - FSW 113 89 Yes Split Note c Preventative - FSW 115 89 Yes Split Note c Preventative - FSW 117 89 Yes Split Note c Preventative - FSW 119 89 Yes Split Note c Preventative - FSW 121 89 Yes Split Note c Preventative - FSW 123 89 Yes Split Note c Preventative - FSW 127 89 Yes Split Note c Preventative - FSW a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89- 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 2 of 16 Page 5 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page _Mof List" 43 1 800873488 U2 NECP U2 NECP Tube 800873488 Plugging/Stabilizing 2E-088 RSG RSG 2E-088 Tube Plugging/Stabilizing List' Row Col Plug Stab Typeb Stab Length (in) Reason 94 90 Yes Split Note c Preventative - FSW 100 90 Yes Split Note c Preventative - FSW 102 90 Yes Split Note c Preventative - FSW 104 90 Yes Split Note c Preventative - FSW 106 90 Yes Split Note c Preventative - FSW 110 90 Yes Split Note c Preventative - FSW 112 90 Yes Split Note c Preventative - FSW 114 90 Yes Split Note c Preventative - FSW 116 90 Yes Split Note c Preventative - FSW 95 91 Yes Split Note c Preventative - FSW 101 91 Yes Split Note c Preventative - FSW 103 91 Yes Split Note c Preventative - FSW 105 91 Yes Split Note c Preventative - FSW 107 91 Yes Split Note c Preventative - FSW 109 91 Yes Split Note c Preventative - FSW 111 91 Yes Split Note c Preventative - FSW 113 91 Yes Split Note c Preventative - FSW 115 91 Yes Split Note c Preventative - FSW 117 91 Yes Split Note c Preventative - FSW 98 92 Yes Split Note c Preventative - FSW 100 92 Yes Split Note c Preventative - FSW 102 92 Yes Split Note c Preventative - FSW 104 92 Yes Split Note c Preventative - FSW 106 92 Yes Split Note c Preventative- FSW 108 92 Yes Split Note c Preventative - FSW 110 92 Yes Split Note c Preventative - FSW 112 92 Yes Split Note c Preventative - FSW 114 92 Yes Split Note c Preventative - FSW 116 92 Yes Split Note c Preventative - FSW 118 92 Yes Split Note c Preventative - FSW 136 92 Yes Split Note c Preventative - FSW 99 93 Yes Split Note c Preventative - FSW 101 93 Yes Split Note c Preventative - FSW 103 93 Yes Split Note c Preventative - FSW a) From AREVA Steam Generator Eddy Current Final Report -San Onofre Nuclear Generating Station (SONGS) Unit 2- Steam Generators 88 & 89- 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 3 of 16 Page 6 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page 31 of 43 1 U2 NECP 800873488 RSG 2E-088 Tube Plugging/Stabilizing Lista Row Col Plug Stab Typeb Stab Length (in) Reason 107 93 Yes Split Note c Preventative - FSW 111 93 Yes Split Note c Preventative - FSW 117 93 Yes Split Note c Preventative - FSW 129 93 Yes Split Note c Preventative - FSW 94 94 Yes Split Note c Preventative -FSW 4

135 93 Yes Split Note c Preventative - FSW 137 89 Yes Split Note c Preventative - FSWd 108 34 Yes None Preventative - Retainer Bar 110 34 Yes Single 668 Preventative - Retainer Bar 111 35 Yes None Preventative - Retainer Bar 109 35 Yes Single 668 Preventative - Retainer Bar 110 36 Yes None Preventative - Retainer Bar 112 36 Yes None Preventative - Retainer Bar 111 37 Yes None Preventative - Retainer Bar 113 37 Yes None Preventative - Retainer Bar 112 38 Yes None Preventative - Retainer Bar 114 38 Yes None Preventative - Retainer Bar 113 39 Yes None Preventative - Retainer Bar 11S 39 Yes None Preventative - Retainer Bar 114 40 Yes None Preventative - Retainer Bar 116 40 Yes None Preventative - Retainer Bar 115 41 Yes None Preventative - Retainer Bar 117 41 Yes None Preventative - Retainer Bar 116 42 Yes None Preventative - Retainer Bar 118 42 Yes None Preventative - Retainer Bar 117 43 Yes None Preventative - Retainer Bar 119 43 Yes None Preventative - Retainer Bar 118 44 Yes None Preventative - Retainer Bar 120 44 Yes None Preventative - Retainer Bar 119 45 Yes None - Preventative - Retainer Bar 121 45 Yes Single 668 Preventative - Retainer Bar 122 46 Yes None - Preventative - Retainer Bar 120 46 Yes Single 668 Preventative - Retainer Bar 121 47 Yes None Preventative - Retainer Bar a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 4 of 16 Page 7 of 19

Klr-f*r I *1*;;;;%/r-Kl, uIm' 6%k

.V.-0A7A0

  • rnnQ7'1A00 D0l n

,.VU.

ACt' ki rnnC)')QC Page ag _322f4of 43 1 U2 NECP 800873488 RSG 2E-088 Tube Plugging/Stabilizing Lista Row Col Plug Stab Typeb Stab Length (in) Reason 123 47 Yes None Preventative - Retainer Bar 122 48 Yes None Preventative - Retainer Bar 123 49 Yes None Preventative - Retainer Bar 124 50 Yes None Preventative - Retainer Bar 126 50 Yes None Preventative - Retainer Bar 125 51 Yes None Preventative - Retainer Bar 127 51 Yes None Preventative - Retainer Bar 126 52 Yes None Preventative - Retainer Bar 128 52 Yes None Preventative - Retainer Bar 127 53 Yes None Preventative - Retainer Bar 129 53 Yes None Preventative - Retainer Bar 128 54 Yes None Preventative - Retainer Bar 130 54 Yes None Preventative - Retainer Bar 129 55 Yes None Preventative - Retainer Bar 131 55 Yes None Preventative - Retainer Bar 130 56 Yes Single 668 Preventative - Retainer Bar 132 56 Yes Single 668 Preventative - Retainer Bar 131 57 Yes None Preventative - Retainer Bar 131 121 Yes None - Preventative - Retainer Bar 130 122 Yes Single 668 Preventative - Retainer Bar 132 122 Yes Single 668 Preventative - Retainer Bar 129 123 Yes None - Preventative - Retainer Bar 131 123 Yes None Preventative - Retainer Bar 128 124 Yes None Preventative - Retainer Bar 130 124 Yes None Preventative - Retainer Bar 127 125 Yes None Preventative - Retainer Bar 129 125 Yes None Preventative - Retainer Bar 126 126 Yes None Preventative - Retainer Bar 128 126 Yes None Preventative - Retainer Bar 125 127 Yes None Preventative - Retainer Bar 127 127 Yes None Preventative - Retainer Bar 124 128 Yes None Preventative - Retainer Bar 126 128 Yes None Preventative - Retainer Bar 123 129 Yes None Preventative - Retainer Bar a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilzer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)

Attachment 3 PAGE S of 16 Page 8 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page 33 of 43 1 U2 NECP 800873488 LiSta RSG ZE-088 Tube Plugging/Stabilizing Row Col Plug Stab Typeb Stab Length (in) Reason 125 129 Yes None Preventative - Retainer Bar 122 130 Yes None Preventative - Retainer Bar 124 130 Yes None Preventative - Retainer Bar 121 131 Yes None Preventative - Retainer Bar 123 131 Yes None Preventative - Retainer Bar 122 132 Yes None - Preventative - Retainer Bar 120 132 Yes Single 668 Preventative - Retainer Bar 119 133 Yes None - Preventative - Retainer Bar 121 133 Yes Single 668 Preventative - Retainer Bar 118 134 Yes None - Preventative - Retainer Bar 120 134 Yes None Preventative - Retainer Bar 117 135 Yes None Preventative - Retainer Bar 119 135 Yes None Preventative - Retainer Bar 116 136 Yes None Preventative - Retainer Bar 118 136 Yes None Preventative - Retainer Bar 115 137 Yes None Preventative - Retainer Bar 117 137 Yes None Preventative - Retainer Bar 114 138 Yes None Preventative - Retainer Bar 116 138 Yes None Preventative - Retainer Bar 113 139 Yes None Preventative - Retainer Bar 115 139 Yes None Preventative - Retainer Bar 112 140 Yes None Preventative - Retainer Bar 114 140 Yes None Preventative - Retainer Bar 111 141 Yes None Preventative - Retainer Bar 113 141 Yes None Preventative - Retainer Bar 110 142 Yes None Preventative - Retainer Bar 112 142 Yes None Preventative - Retainer Bar 111 143 Yes None - Preventative - Retainer Bar 109 143 Yes Single 668 Preventative - Retainer Bar 108 144 Yes None - Preventative - Retainer Bar 110 144 Yes Single 668 Preventative - Retainer Bar 98 84 Yes Split Note c Wear at 6 Continuous AVBs 88 88 Yes Split Note c Wear at 6 Continuous AVBs 97 89 Yes Split Note c Wear at 6 Continuous AVBs a) From AREVA Steam Generator Eddy Current Final Report -San Onofre Nuclear Generating Station (SONGS) Unit 2- Steam Generators 88 & 89- 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 6 of 16 Page 9 of 19

NECP Number 800873488 Rev 0 ASC No- D0062286 Page 34 of 43 1 U2 NECP 800873488 RSG 2E-088 Tube Plugging/Stabilizing Lista Row Col Plug Stab Typeb Stab Length (in) Reason 108 90 Yes Split Note c Wear at 6 Continuous AVBs 124 92 Yes Split Note c Wear at 6 Continuous AVBs 134 94 Yes Split Note c Wear at 6 Continuous AVBs a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 7 of 16 Page 10 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page 35 of 43 1 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row Col Plug Stab Typeb Stab Length (in) Reason 111 81 Yes Split Note c 14% TWD- FSW (Preventative) 113 81 Yes Split Note c 14% TWD- FSW (Preventative) 127 127 Yes Single 668 38% TWD - Retainer Bar 119 133 Yes Single 668 90% TWD - Retainer Bar 103 77 Yes Split Note c Preventative - FSW 109 77 Yes Split Note c Preventative - FSW 111 77 Yes Split Note c Preventative - FSW 100 78 Yes Split Note c Preventative - FSW 102 78 Yes Split Note c Preventative - FSW 104 78 Yes Split Note c Preventative - FSW 108 78 Yes Split Note c Preventative - FSW 110 78 Yes Split Note c Preventative - FSW 112 78 Yes Split Note c Preventative - FSW 97 79 Yes Split Note c Preventative - FSW 99 79 Yes Split Note c Preventative - FSW 101 79 Yes Split Note c Preventative - FSW 112 79 Yes Split Note c Preventative - FSW 92 80 Yes Split Note c Preventative - FSW 94 80 Yes Split Note c Preventative - FSW 96 80 Yes Split Note c Preventative - FSW 98 80 Yes Split Note c Preventative - FSW 100 80 Yes Split Note c Preventative - FSW 102 80 Yes Split Note c Preventative - FSW 110 80 Yes Split Note c Preventatve - FSW 112 80 Yes Split Note c Preventative - FSW 114 80 Yes Split Note c Preventative - FSW 91 81 Yes Split Note c Preventative - FSW 93 81 Yes Split Note c Preventative - FSW 9S 81 Yes Split Note c Preventative - FSW 97 81 Yes Spilt Note c Preventative - FSW 99 81 Yes Split Note c Preventative - FSW 101 81 Yes Split Note c Preventative - FSW 1U3 81 Yes Split Note c Preventative - FSW 106 81 Yes Split Note c Preventative - FSW 107 81 Yes Split Note c Preventative - FSW a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 -Steam Generators 88 & 89-2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabiizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 8 of 16 Page 11 of 19

Klal*¢' m r'4i*.

I k,,k UM~'f V1..k,.

o/1nn OAO'O 7"1A00 13-eA DU.

A0i'M nma'31)012 Page Pg 366 off4 43 1 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Lista Row Col Plug Stab Typeb Stab Length (in) Reason 109 81 Yes Split Note c Preventative - FSW 115 81 Yes Split Note c Preventative - FSW 117 81 Yes Split Note c Preventative - FSW 119 81 Yes Split Note c Preventative - FSW 121 81 Yes Split Note c Preventative - FSW 90 82 Yes Split Note c Preventative - FSW 92 82 Yes Split Note c Preventative - FSW 94 82 Yes Split Note c Preventative - FSW 96 82 Yes Split Note c Preventative - FSW 98 82 Yes Split Note c Preventative - FSW 100 82 Yes Split Note c Preventative - FSW 102 82 Yes Split Note c Preventative - FSW 104 82 Yes Split Note c Preventative - FSW 106 82 Yes Split Note c Preventative - FSW 108 82 Yes Split Note c Preventative - FSW 110 82 Yes Split Note c Preventative - FSW 112 82 Yes Split Note c Preventative - FSW 114 82 Yes Split Note c Preventative - FSW 116 82 Yes Split Note c Preventative - FSW 118 82 Yes Split Note c Preventative - FSW 120 82 Yes Split Note c Preventative - FSW 122 82 Yes Split Note c Preventative - FSW 91 83 Yes Split Note c Preventative - FSW 93 83 Yes Split Note c Preventative - FSW 95 83 Yes Split Note c Preventative - FSW 97 83 Yes Split Note c Preventative - FSW 99 83 Yes Split Note c Preventative - FSW 101 83 Yes Split Note c Preventative - FSW 103 83 Yes Split Note c Preventative - FSW 105 83 Yes Split Note c Preventative - FSW 107 83 Yes Split Note c Preventative - FSW 109 83 Yes Split Note c Preventative - FSW 11 83 Yes Split Note c Preventative - FSW 113 83 Yes Split Note c Preventative - FSW S115 83 Yes Split Notec Preventative - FSW a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2- Steam Generators 88 & 89- 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23)

Attachment 3 PAGE 9 of 16 Page 12 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page 37 of 43 1 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row Col Plug Stab Typeb Stab Length (in) Reason 117 83 Yes Split Note c Preventative - FSW 119 83 Yes Split Note c Preventatve - FSW 121 83 Yes Split Note c Preventative - FSW 90 84 Yes Split Note c Preventative - FSW 92 84 Yes Split Note c Preventative - FSW 94 84 Yes Split Note c Preventative - FSW 96 84 Yes Split Note c Preventative - FSW 98 84 Yes Split Note c Preventative - FSW 100 84 Yes Split Note c Preventative - FSW 102 84 Yes Split Note c Preventative - FSW 104 84 Yes Split Note c Preventatlve - FSW 106 84 Yes Split Note c Preventative - FSW 106 84 Yes Split Note c Preventative - FSW 110 84 Yes Split Note c Preventative - FSW 112 84 Yes Split Note c Preventative - FSW 114 84 Yes Split Note c Preventative - FSW 116 84 Yes Split Note c Preventative - FSW 118 84 Yes Split Note c Preventative - FSW 120 84 Yes Split Note c Preventative - FSW 126 84 Yes Split Note c Preventative - FSW 128 84 Yes Split Note c Preventative - FSW 132 84 Yes Split Note c Preventative - FSW 91 85 Yes Split Note c Preventative - FSW 93 85 Yes Split Note c Preventative - FSW 95 85 Yes Split Note c Preventative - FSW 97 85 Yes Split Note c Preventativ - FSW 99 85 Yes Split Note c Preventative - FSW 101 85 Yes Split Note c Preventative - FSW 103 85 Yes Split Note c Preventative - FSW 105 85 Yes Split Note c Preventative - FSW 107 85 Yes Split Note c Preventative - FSW 109 85 Yes Split Note c Preventative - FSW 1U 85 Yes Split Note c Preventative - FSW 113 85 Yes Split Note c Preventative - FSW 115 85 Yes Split Note c Preventative - FSW a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Stea m Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 10 of 16 Page 13 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page 38 of 43 1

U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Lista Row Col Plug Stab Typeb Stab Length (in) Reason 117 85 Yes Split Note c Preventative - FSW 119 85 Yes Split Note c Preventative - FSW 121 85 Yes Split Note c Preventative - FSW 127 85 Yes Split Note c Preventative - FSW 88 86 Yes Split Note c Preventative - FSW 92 86 Yes Split Note c Preventative - FSW 94 86 Yes Split Note c Preventative - FSW 96 86 Yes Split Note c Preventative - FSW 98 86 Yes Split Note c Preventative - FSW 100 86 Yes Split Note c Preventative - FSW 102 86 Yes Split Note c Preventative - FSW 104 86 Yes Split Note c Preventative - FSW 106 86 Yes Split Note c Preventative - FSW 108 86 Yes Split Note c Preventative - FSW 110 86 Yes Split Note c Preventative - FSW 112 86 Yes Split Note c Preventative - FSW 114 86 Yes Split Note c Preventative - FSW 116 86 Yes Split Note c Preventative - FSW 118 86 Yes Split Note c Preventative - FSW 122 86 Yes Split Note c Preventative - FSW 130 86 Yes Split Note c Preventative - FSW 93 87 Yes Split Note c Preventative - FSW 95 87 Yes Split Note c Preventative - FSW 97 87 Yes Split Note c Preventative - FSW 99 87 Yes Split Note c Preventative - FSW 101 87 Yes Split Note c Preventative - FSW 103 87 Yes Split Note c Preventative - FSW 105 87 Yes Split Note c Preventative - FSW 107 87 Yes Split Note c Preventative - FSW 109 87 Yes Split Note c Preventative - FSW 111 87 Yes Split Note c Preventative - FSW 113 87 Yes Split Note c Preventative - FSW 115 87 Yes Split Note c Preventative - FSW 117 87 Yes Split Note c Preventative - FSW 119 87 Yes Split Note c Preventative - FSW a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 -Steam Generators 88 & 89- 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 11 of 16 Page 14 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page 39 of 43 1 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row Col Plug Stab Typeb Stab Length (in) Reason 129 87 Yes Split Note c Preventative - FSW 94 88 Yes Split Note c Preventative - FSW 96 88 Yes Split Note c Preventative - FSW 98 88 Yes Split Note c Preventative - FSW 100 88 Yes Split Note c Preventative - FSW 102 88 Yes Split Note c Preventative - FSW 104 88 Yes Split Note c Preventative - FSW 106 88 Yes Split Note c Preventative - FSW 10 88 Yes Split Note c Preventative - FSW 110 88 Yes Split Note c Preventative- FSW 112 88 Yes Split Note c Preventative - FSW 114 88 Yes Split Note c Preventative - FSW 116 88 Yes Split Note c Preventative - FSW 118 88 Yes Split Note c Preventative - FSW 138 88 Yes Split Note c Preventative - FSW 95 89 Yes Split Note c Preventative - FSW 97 89 Yes Split Note c Preventative - FSW 99 89 Yes Split Note c Preventative - FSW 101 89 Yes Split Note c Preventative - FSW 103 89 Yes Split Note c Preventatlve - FSW 105 89 Yes Split Note c Preventative - FSW 107 89 Yes Split Note c Preventative - FSW 109 89 Yes Split Note c Preventative - FSW 111 89 Yes Split Note c Preventative - FSW 113 89 Yes Split Note c Preventative - FSW 115 89 Yes Split Note c Preventative - FSW 117 89 Yes Split Note c Preventative - FSW 131 89 Yes Split Note c Preventative - FSW 100 90 Yes split Note c Preventative - FSW 102 90 Yes Split Note c Preventative - FSW 104 90 Yes Split Note c Preventative - FSW 106 90 Yes Split Note c Preventative - FSW 108 90 Yes Split Note c Preventative - FSW 110 90 Yes Split Note c Preventative - FSW 112 90 Yes Split Note c Preventative - FSW a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 12 of 16 Page 15 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page 40 of 43 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row Col Plug Stab Type? Stab Length (in) Reason 114 90 Yes Split Note c Preventative - FSW 116 90 Yes Split Note c Preventative - FSW 118 90 Yes Split Note c Preventative - FSW 130 90 Yes Split Note c Preventative - FSW 132 90 Yes Split Note c Preventative - FSW 134 90 Yes Split Note c Preventative - FSW 99 91 Yes Split Note c Preventative - FSW 105 91 Yes Split Note c Preventative - FSW 107 91 Yes Split Note c Preventative - FSW 109 91 Yes Split Note c Preventative - FSW 113 91 Yes Split Note c Preventative - FSW 115 91 Yes Split Note c Preventative - FSW 117 91 Yes Split Note c Preventative - FSW 123 91 Yes Split Note c Preventative - FSW 98 92 Yes Split Note c Preventative - FSW 104 92 Yes Split Note c Preventative - FSW 108 92 Yes Split Note c Preventative - FSW 114 92 Yes Split Note c Preventative- FSW 116 92 Yes Split Note c Preventative - FSW 103 93 Yes Split Note c Preventative - FSW 115 93 Yes Split Note c Preventative - FSW 102 94 Yes Split Note c Preventative - FSW 114 94 Yes Split Note c Preventative - FSW 116 94 Yes Split Note c Preventative - FSW 103 95 Yes Split Note c Preventative - FSW 105 95 Yes Split Note c Preventative - FSW 107 95 Yes Split Note c Preventative - FSW 109 95 Yes Split Note c Preventative - FSW 115 95 Yes Split Note c Preventative - FSW 109 97 Yes Split Note c Preventative - FSW 110 98 Yes Split Note c Preventative - FSW 112 98 Yes Split Note c Preventative - FSW 80 68 Yes Split Note c Preventative - FSWd 104 72 Yes Split Nate c Preventative - FSWd 132 94 Yes Split Note c Preventative - FSWd a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 -Steam Generators 88 &89 -2012-UJ2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabiizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 13 of 16 Page 16 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page 41 of 43 /

U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row Col Plug Stab Typeb Stab Length (in) Reason 108 34 Yes None - Preventative - Retainer Bar 110 34 Yes Single 668 Preventative - Retainer Bar 111 35 Yes None - Preventative - Retainer Bar 109 35 Yes Single 668 Preventative - Retainer Bar 110 36 Yes None - Preventative - Retainer Bar 112 36 Yes None Preventative - Retainer Bar 111 37 Yes None Preventative - Retainer Bar 113 37 Yes None Preventative - Retainer Bar 112 38 Yes None Preventative - Retainer Bar 114 38 Yes None Preventative - Retainer Bar 113 39 Yes None Preventative - Retainer Bar 115 39 Yes None Preventative - Retainer Bar 114 40 Yes None Preventative - Retainer Bar 116 40 Yes None Preventative - Retainer Bar 115 41 Yes None Preventative - Retainer Bar 117 41 Yes None Preventative - Retainer Bar 116 42 Yes None Preventative - Retainer Bar 118 42 Yes None Preventative - Retainer Bar 117 43 Yes None Preventative - Retainer Bar 119 43 Yes None Preventative - Retainer Bar 120 44 Yes None - Preventative - Retainer Bar 118 44 Yes Single 668 Preventative - Retainer Bar 119 45 Yes None - Preventative - Retainer Bar 121 4S Yes Single 668 Preventative - Retainer Bar 122 46 Yes None - Preventative - Retainer Bar 120 46 Yes Single 668 Preventative - Retainer Bar 121 47 Yes None - Preventative - Retainer Bar 123 47 Yes None Preventative - Retainer Bar 122 48 Yes None Preventative - Retainer Bar 124 48 Yes None Preventative - Retainer Bar 123 49 Yes None Preventative - Retainer Bar 125 49 Yes None Preventative - Retainer Bar 124 50 Yes None Preventative - Retainer Bar 126 50 Yes None Preventative - Retainer Bar 125 51 Yes None Preventative - Retainer Bar a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 14 of 16 Page 17 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page 42 of 43 1 ASC No D0062286 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row Col Plug Stab Typeb Stab Length (in) Reason 127 51 Yes None Preventative - Retainer Bar 126 52 Yes None Preventative - Retainer Bar 128 52 Yes None Preventative - Retainer Bar 127 53 Yes None Preventative - Retainer Bar 129 53 Yes None Preventative - Retainer Bar 128 54 Yes None Preventative - Retainer Bar 130 54 Yes None Preventative - Retainer Bar 129 55 Yes None Preventative - Retainer Bar 131 55 Yes None - Preventative - Retainer Bar 130 56 Yes Single 668 Preventative - Retainer Bar 132 56 Yes Single 668 Preventative - Retainer Bar 131 57 Yes None Preventative - Retainer Bar 131 121 Yes None - Preventative - Retainer Bar 130 122 Yes Single 668 Preventative - Retainer Bar 132 122 Yes Single 668 Preventative - Retainer Bar 129 123 Yes None - Preventative - Retainer Bar 131 123 Yes None Preventative - Retainer Bar 128 124 Yes None Preventative - Retainer Bar 130 124 Yes None Preventative - Retainer Bar 127 125 Yes None Preventative - Retainer Bar 129 125 Yes None Preventative - Retainer Bar 126 126 Yes None Preventative - Retainer Bar 128 126 Yes None Preventative - Retainer Bar 125 127 Yes None Preventative - Retainer Bar 124 128 Yes None Preventative - Retainer Bar 126 128 Yes None Preventative - Retainer Bar 123 129 Yes None Preventative - Retainer Bar 125 129 Yes None Preventative - Retainer Bar 122 130 Yes None Preventative - Retainer Bar 124 130 Yes None Preventative - Retainer Bar 121 131 Yes None Preventative - Retainer Bar 123 131 Yes None Preventative - Retainer Bar 122 132 Yes None - Preventative - Retainer Bar 120 132 Yes Single 668 Preventative - Retainer Bar 121 133 Yes Single 668 Preventative - Retainer Bar a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 - Steam Generators 88 & 89 - 2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 15 of 16 Page 18 of 19

NECP Number 800873488 Rev 0 ASC No. D0062286 Page 43 of 43 1 U2 NECP 800873488 RSG 2E-089 Tube Plugging/Stabilizing Usta Row Col Plug StabTypeb Stab Length (in) Reason 118 134 Yes None Preventative - Retainer Bar 120 134 Yes None Preventative - Retainer Bar 117 135 Yes None Preventative - Retainer Bar 119 135 Yes None Preventative - Retainer Bar 116 136 Yes None Preventative - Retainer Bar 118 136 Yes None Preventative - Retainer Bar 115 137 Yes None Preventative - Retainer Bar 117 137 Yes None Preventative - Retainer Bar 114 138 Yes None Preventative - Retainer Bar 116 138 Yes None Preventative - Retainer Bar 113 139 Yes None Preventative - Retainer Bar 115 139 Yes None Preventative - Retainer Bar 112 140 Yes None Preventative - Retainer Bar 114 140 Yes None Preventative - Retainer Bar 111 141 Yes None Preventative - Retainer Bar 113 141 Yes None Preventative - Retainer Bar 110 142 Yes None Preventative - Retainer Bar 112 142 Yes None Preventative - Retainer Bar 111 143 Yes None - Preventative - Retainer Bar 109 143 Yes Single 668 Preventative - Retainer Bar 108 144 Yes None Preventative - Retainer Bar 110 144 Yes Single 668 Preventative - Retainer Bar 98 76 Yes Split Note c Wear at 6 Continuous AVBs 87 79 Yes Split Note c Wear at 6 Continuous AVBs 89 83 Yes Split Note c Wear at 6 Continuous AVBs 122 84 Yes Split Note c Wear at 6 Continuous AVys 121 89 Yes Split Note c Wear at 6 Continuous AVBs 120 90 Yes Split Note c Wear at 6 Continuous AVBs a) From AREVA Steam Generator Eddy Current Final Report - San Onofre Nuclear Generating Station (SONGS) Unit 2 -Steam Generators 88 & 89-2012-U2C17 & Return to Service b) Single stabilizers are installed on the hot side of the tube, split stabilizers are installed on the hot and cold side of the tube c) See AREVA Product Information Sheet for Stabilizer U-Bend (Ref. 15) for split stabilizer lengths d) Conservatively plugged as a defense in depth action per Westinghouse recommendation (Ref. 23) PAGE 16 of 16 Page 19 of 19