Issue date | From | Title | Project stage | |
---|---|---|---|---|
ML12285A265 | 1 October 2012 | Southern California Edison Mitsubishi Heavy Industries Ltd | Attachment 4 - MHI Document L5-04GA564 - Tube Wear of Unit-3 RSG, Technical Evaluation Report | Request |
ML12285A267 | 1 October 2012 | Southern California Edison Mitsubishi Heavy Industries Ltd | Attachment 4: SG Tube Wear Analysis for Unit-2/3 | Request |
ML12285A266 | 1 October 2012 | Southern California Edison Mitsubishi Heavy Industries Ltd | Attachment 4: Appendix-2 Attachment-1, Tube-to-TSP Wear Depth Diagram for Unit-2/3 | Request |
ML12285A264 | 1 October 2012 | Southern California Edison AREVA NP | Attachment 3 - Areva Document 51-9180143-001 - SONGS Unit 3 February 2012 Leaker Outage Steam Generator Condition Monitoring Report | Request |
ML12285A268 | 2 October 2012 | Southern California Edison AREVA NP | Attachment 6 - Appendix B: SONGS U2C17 - Steam Generator Operational Assessment for Tube-to-Tube Wear | Request |
ML12285A269 | 2 October 2012 | AREVA NP | Attachment 6: Appendix a: Estimates of FEI-Induced Ttw Rates | Request |
ML12285A263 | 3 October 2012 | Southern California Edison Peter Dietrich | Confirmatory Action Letter - Actions to Address Steam Generator Tube Degradation | Request |
ML12338A110 | 30 November 2012 | Hall J Plant Licensing Branch IV | Email, Request for Additional Information Southern California Edison'S Response to Nrc'S Confirmatory Action Letter (CAL) 4-12-001 Dated March 27, 2012 | RAI |
ML12341A112 | 7 December 2012 | Division of Operating Reactor Licensing Hall J | Notice of Meeting with Southern California Edison to Discuss Its Response to Nrc'S Confirmatory Action Letter and Return to Service Report for San Onofre Nuclear Generating Station, Unit 2 | Meeting |
ML12347A066 | 7 December 2012 | Division of Operating Reactor Licensing Hall J | Revised Notice of 12/18/12 Meeting with Southern California Edison to Discuss Its Response to Nrc'S Confirmatory Action Letter and Return to Service Report for San Onofre Nuclear Generating Station, Unit 2 | Meeting |
ML12345A427 | 10 December 2012 | Hall J Plant Licensing Branch IV | Revised Email, Request for Additional Information Review of Southern California Edison'S Response to Nrc'S 3/27/2012 Confirmatory Action Letter (CAL) 4-12-001 and Return to Service Report | RAI |
ML12353A097 | 13 December 2012 | - No Known Affiliation Leichtling D | LTR-12-0795 - E-mail Don Leichtling Concerns Media Alert - Nuclear News - NRR Forthcoming Meeting with Southern California Edison Company | Meeting |
ML12352A385 | 18 December 2012 | Southern California Edison | Licensee Slides for 12/18/12 Public Meeting | Meeting |
ML12352A411 | 18 December 2012 | Plant Licensing Branch IV | NRC Slides for 12/18/12 Meeting with Southern California Edison | Meeting |
ML12356A198 | 20 December 2012 | Hall J Plant Licensing Branch IV | Email, Request for Additional Information, Round 3, Review of Southern California Edison'S Response to Nrc'S 3/27/2012 Confirmatory Action Letter (CAL) 4-12-001 and Return to Service Report | RAI |
ML13009A349 | 8 January 2013 | Southern California Edison St.Onge R Edison International Co | Response to Request for Additional Information Regarding Confirmatory Action Letter Response | Response to RAI |
ML13014A251 | 9 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 30) Regarding Confirmatory Action Letter Response | Response to RAI |
ML13014A249 | 9 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 15) Regarding Confirmatory Action Letter Response | Response to RAI |
ML13015A004 | 10 January 2013 | Southern California Edison St-Onge R | Response to Request for Additional Information (RAI 16), Regarding Confirmatory Action Letter Response (TAC No. Me 9727) | Response to RAI |
ML13022A088 | 16 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 19) Regarding Confirmatory Action Letter Response (TAC No. Me 9727) | Response to RAI |
ML13022A413 | 17 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAIs 10 and 17) Regarding Confirmatory Action Letter Response | Response to RAI |
ML13022A481 | 18 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 13), Regarding Confirmatory Action Letter Response | Response to RAI |
ML13022A408 | 18 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 12), Regarding Confirmatory Action Letter Response (TAC No. Me 9727) | Response to RAI |
ML13022A411 | 21 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 11) Regarding Confirmatory Action Letter Response (TAC Me 9727) | Response to RAI |
ML13022A405 | 21 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 28), Regarding Confirmatory Action Letter Response (TAC No. Me 9727) | Response to RAI |
ML13028A098 | 24 January 2013 | Southern California Edison St-Onge R | Response to Request for Additional Information (RAI 18) Regarding Confirmatory Action Letter Response | Response to RAI |
ML13028A475 | 25 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 27) Regarding Confirmatory Action Letter | Response to RAI |
ML13028A474 | 25 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAIs 5, 7, and 9) Regarding Confirmatory Action Letter Response | Response to RAI |
ML13032A009 | 29 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 14) Regarding Confirmatory Action Letter Response (TAC No. Me 9727) | Response to RAI |
ML13037A112 | 31 January 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 29) Regarding Confirmatory Action Letter Response | Response to RAI |
ML13053A367 | 1 February 2013 | Hall J Plant Licensing Branch IV | E-mail, Draft Request for Additional Information Southern California Edison'S Response to Nrc'S Confirmatory Action Letter | Draft RAI |
ML13038A010 | 4 February 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 8) Regarding Confirmatory Action Letter Response | Response to RAI |
ML13038A009 | 4 February 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 6) Regarding Confirmatory Action Letter Response | Response to RAI |
ML13039A278 | 6 February 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAIs 20, 21, 22, 23, 24, 26 & 31), Confirmatory Action Letter | Response to RAI |
ML13039A317 | 7 February 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 25) Regarding Confirmatory Action Letter Response | Response to RAI |
ML13050A189 | 14 February 2013 | Southern California Edison St.Onge R | Supplemental Document Submittal Regarding Confirmatory Action Letter Response, Concerning Steam Generator Tubes | Supplement |
ML13051A197 | 15 February 2013 | Westinghouse Hall J Bell B Cullen W Langford P Norman T Pournaras T Prabhu P Thakkar J | Enclosure 6, LTR-SGDA-12-36, Rev. 3, Flow-Induced Vibration and Tube Wear Analysis of the San Onofre Nuclear Generating Station Unit 2 Replacement Steam Generators Supporting Restart. Cover Through Page 227 of 415 | Other |
ML13051A199 | 15 February 2013 | Westinghouse Hall J Bell B Cullen W Langford P Norman T Pournaras T Prabhu P Thakkar J | Enclosure 6, LTR-SGDA-12-36, Rev. 3, Flow-Induced Vibration and Tube Wear Analysis of the San Onofre Nuclear Generating Station Unit 2 Replacement Steam Generators Supporting Restart. Page 228 of 415 Through End | Other |
ML13046A123 | 15 February 2013 | Division of Operating Reactor Licensing Hall J | 2/27/2013 Notice of Forthcoming Meeting with Southern California Edison Company to Discuss Confirmation Action Letter | Meeting |
ML13051A193 | 18 February 2013 | Mitsubishi Heavy Industries Ltd | Enclosure 5, L5-04GA585, Rev. 2, Analytical Evaluations for Operational Assessment | Other |
ML13051A192 | 18 February 2013 | Mitsubishi Heavy Industries Ltd | Enclosure 4, L5-04GA567, Rev. 6, Evaluation of Stability Ratio for Return to Service | Other |
ML13051A190 | 18 February 2013 | Southern California Edison St.Onge R Edison International Co | Supplemental Document Submittal Regarding Confirmatory Action Letter Response to Address Steam Generator Tube Degradation | Supplement |
ML13056A092 | 20 February 2013 | Hall J Plant Licensing Branch IV | Email, Draft Request for Additional Information Nos. 38-52, Southern California Edison'S Response to Nrc'S Confirmatory Action Letter | Draft RAI |
ML13053A173 | 21 February 2013 | Hall J Plant Licensing Branch IV | Email, Draft Request for Additional Information, Nos. 53-67, Southern California Edison'S Response to Nrc'S Confirmatory Action Letter | Draft RAI |
ML13053A184 | 21 February 2013 | Hall J Plant Licensing Branch IV | Draft Request for Additional Information, Nos. 53-67, Southern California Edison'S Response to Nrc'S Confirmatory Action Letter | Draft RAI |
ML13058A026 | 25 February 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (Rals 2, 3, and 4) Regarding Confirmatory Action Letter Response (TAC No. Me 9727) | Response to RAI |
ML13056A601 | 25 February 2013 | Southern California Edison St.Onge R | Response to Request for Additional Information (RAI 32) Regarding Confirmatory Action Letter Response | Response to RAI |
ML13059A157 | 27 February 2013 | Southern California Edison | Licensee Slides from 2/27/13 Meeting Regarding a Request for Additional Information | Meeting |
ML13059A152 | 27 February 2013 | Doug Broaddus Division of Operating Reactor Licensing | NRC Meeting Slides from 2/27/13 Public RAI Meeting | RAI |
ML13074A793 | 14 March 2013 | Southern California Edison St.Onge R | Operational Assessment for 100% Power Case Regarding Confirmatory Action Letter Response | Other |