MONTHYEARML12118A1392012-04-20020 April 2012 Units 2 & 3 Components, Portions Outside of Scope Project stage: Request ML12285A2672012-10-0101 October 2012 Attachment 4: SG Tube Wear Analysis for Unit-2/3 Project stage: Request ML12285A2652012-10-0101 October 2012 Attachment 4 - MHI Document L5-04GA564 - Tube Wear of Unit-3 RSG, Technical Evaluation Report Project stage: Request ML12285A2662012-10-0101 October 2012 Attachment 4: Appendix-2 Attachment-1, Tube-to-TSP Wear Depth Diagram for Unit-2/3 Project stage: Request ML12285A2642012-10-0101 October 2012 Attachment 3 - Areva Document 51-9180143-001 - SONGS Unit 3 February 2012 Leaker Outage Steam Generator Condition Monitoring Report Project stage: Request ML12285A2682012-10-0202 October 2012 Attachment 6 - Appendix B: SONGS U2C17 - Steam Generator Operational Assessment for Tube-to-Tube Wear Project stage: Request ML12285A2692012-10-0202 October 2012 Attachment 6: Appendix a: Estimates of FEI-Induced Ttw Rates Project stage: Request ML12285A2632012-10-0303 October 2012 Confirmatory Action Letter - Actions to Address Steam Generator Tube Degradation Project stage: Request ML12335A2972012-11-28028 November 2012 LTR-12-0728 - Ltr. Ricardo Nicol Concerns Restart of San Onofre Nuclear Generating Station Project stage: Request ML12338A1102012-11-30030 November 2012 Email, Request for Additional Information Southern California Edisons Response to NRCs Confirmatory Action Letter (CAL) 4-12-001 Dated March 27, 2012 Project stage: RAI ML12341A1122012-12-0707 December 2012 Notice of Meeting with Southern California Edison to Discuss Its Response to NRCs Confirmatory Action Letter and Return to Service Report for San Onofre Nuclear Generating Station, Unit 2 Project stage: Meeting ML12347A0662012-12-0707 December 2012 Revised Notice of 12/18/12 Meeting with Southern California Edison to Discuss Its Response to NRCs Confirmatory Action Letter and Return to Service Report for San Onofre Nuclear Generating Station, Unit 2 Project stage: Meeting ML12345A4272012-12-10010 December 2012 Revised Email, Request for Additional Information Review of Southern California Edisons Response to NRCs 3/27/2012 Confirmatory Action Letter (CAL) 4-12-001 and Return to Service Report Project stage: RAI ML12353A0972012-12-13013 December 2012 LTR-12-0795 - E-mail Don Leichtling Concerns Media Alert - Nuclear News - NRR Forthcoming Meeting with Southern California Edison Company Project stage: Meeting ML12352A3852012-12-18018 December 2012 Licensee Slides for 12/18/12 Public Meeting Project stage: Meeting ML12352A4112012-12-18018 December 2012 NRC Slides for 12/18/12 Meeting with Southern California Edison Project stage: Meeting ML12356A1982012-12-20020 December 2012 Email, Request for Additional Information, Round 3, Review of Southern California Edisons Response to NRCs 3/27/2012 Confirmatory Action Letter (CAL) 4-12-001 and Return to Service Report Project stage: RAI ML12361A0652012-12-26026 December 2012 Request for Additional Information Regarding Response to Confirmatory Action Letter Project stage: RAI ML13009A3492013-01-0808 January 2013 Response to Request for Additional Information Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13014A2492013-01-0909 January 2013 Response to Request for Additional Information (RAI 15) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13014A2512013-01-0909 January 2013 Response to Request for Additional Information (RAI 30) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13015A0042013-01-10010 January 2013 Response to Request for Additional Information (RAI 16), Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13022A0882013-01-16016 January 2013 Response to Request for Additional Information (RAI 19) Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13022A4132013-01-17017 January 2013 Response to Request for Additional Information (RAIs 10 and 17) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13022A4812013-01-18018 January 2013 Response to Request for Additional Information (RAI 13), Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13022A4082013-01-18018 January 2013 Response to Request for Additional Information (RAI 12), Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13018A4452013-01-18018 January 2013 Natural Resources Defense Councils Amicus Response in Support of Friends of the Earth Opening Brief Project stage: Request ML13022A4052013-01-21021 January 2013 Response to Request for Additional Information (RAI 28), Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13022A4112013-01-21021 January 2013 Response to Request for Additional Information (RAI 11) Regarding Confirmatory Action Letter Response (TAC Me 9727) Project stage: Response to RAI ML13028A0982013-01-24024 January 2013 Response to Request for Additional Information (RAI 18) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13028A4742013-01-25025 January 2013 Response to Request for Additional Information (RAIs 5, 7, and 9) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13028A4752013-01-25025 January 2013 Response to Request for Additional Information (RAI 27) Regarding Confirmatory Action Letter Project stage: Response to RAI ML13032A0092013-01-29029 January 2013 Response to Request for Additional Information (RAI 14) Regarding Confirmatory Action Letter Response (TAC No. Me 9727) Project stage: Response to RAI ML13037A1122013-01-31031 January 2013 Response to Request for Additional Information (RAI 29) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13053A3672013-02-0101 February 2013 E-mail, Draft Request for Additional Information Southern California Edisons Response to NRCs Confirmatory Action Letter Project stage: Draft RAI ML13038A0102013-02-0404 February 2013 Response to Request for Additional Information (RAI 8) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13038A0092013-02-0404 February 2013 Response to Request for Additional Information (RAI 6) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13039A2782013-02-0606 February 2013 Response to Request for Additional Information (RAIs 20, 21, 22, 23, 24, 26 & 31), Confirmatory Action Letter Project stage: Response to RAI ML13039A3172013-02-0707 February 2013 Response to Request for Additional Information (RAI 25) Regarding Confirmatory Action Letter Response Project stage: Response to RAI ML13050A1892013-02-14014 February 2013 Supplemental Document Submittal Regarding Confirmatory Action Letter Response, Concerning Steam Generator Tubes Project stage: Supplement ML13051A1992013-02-15015 February 2013 Enclosure 6, LTR-SGDA-12-36, Rev. 3, Flow-Induced Vibration and Tube Wear Analysis of the San Onofre Nuclear Generating Station Unit 2 Replacement Steam Generators Supporting Restart. Page 228 of 415 Through End Project stage: Other ML13046A1232013-02-15015 February 2013 2/27/2013 Notice of Forthcoming Meeting with Southern California Edison Company to Discuss Confirmation Action Letter Project stage: Meeting ML13051A1972013-02-15015 February 2013 Enclosure 6, LTR-SGDA-12-36, Rev. 3, Flow-Induced Vibration and Tube Wear Analysis of the San Onofre Nuclear Generating Station Unit 2 Replacement Steam Generators Supporting Restart. Cover Through Page 227 of 415 Project stage: Other ML13051A1902013-02-18018 February 2013 Supplemental Document Submittal Regarding Confirmatory Action Letter Response to Address Steam Generator Tube Degradation Project stage: Supplement ML13051A1922013-02-18018 February 2013 Enclosure 4, L5-04GA567, Rev. 6, Evaluation of Stability Ratio for Return to Service Project stage: Other ML13051A1932013-02-18018 February 2013 Enclosure 5, L5-04GA585, Rev. 2, Analytical Evaluations for Operational Assessment Project stage: Other ML13056A0922013-02-20020 February 2013 Email, Draft Request for Additional Information Nos. 38-52, Southern California Edisons Response to NRCs Confirmatory Action Letter Project stage: Draft RAI ML13053A1842013-02-21021 February 2013 Draft Request for Additional Information, Nos. 53-67, Southern California Edisons Response to NRCs Confirmatory Action Letter Project stage: Draft RAI ML13053A1732013-02-21021 February 2013 Email, Draft Request for Additional Information, Nos. 53-67, Southern California Edisons Response to NRCs Confirmatory Action Letter Project stage: Draft RAI ML13056A6012013-02-25025 February 2013 Response to Request for Additional Information (RAI 32) Regarding Confirmatory Action Letter Response Project stage: Response to RAI 2013-01-21
[Table View] |
Text
May 9, 2013 MEMORANDUM TO: File FROM:
Brian Benney, Senior Project Manager /RA/
SONGS Special Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
SUBJECT:
CLARIFICATION CALL WITH SOUTHERN CALIFORNIA EDISON (TAC NO. MF1379)
On April 29, 2013, the U.S. Nuclear Regulatory Commission (NRC) held a telephone call with Southern California Edison (SCE) to clarify information submitted in the San Onofre Nuclear Generating Station, Unit 2, license amendment request (LAR) submitted on April 5, 2013, and supplemented on April 9, 2013 (Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML13098A043 and ML13100A021, respectively). The NRC staff sought clarification regarding information referenced and discussed in the LAR and supplement that was previously provided in the April 2, 2013, response to NRC request for additional information 11, Revision 1 (ADAMS Accession No. ML13094A077), related to the licensees October 3, 2012 confirmatory action letter response. In particular, the NRC staff sought clarification concerning procedural changes for the power dependent Technical Specification Surveillance Requirements (SRs) 3.2.2.1, 3.2.3.3, 3.3.1.2, 3.3.1.5, and 3.3.1.11.
The licensee confirmed for the NRC staff that, although SRs 3.2.2.1, 3.2.3.3, and 3.3.1.11 are power dependent, their performance would not be impacted by the proposed restricted 70%
power, and the procedural changes are intended to ensure they will be performed at or before the required frequency. The licensee also indicated that it planned to supplement the LAR with additional license conditions to more clearly demonstrate that it will perform SRs 3.3.1.2 and 3.3.1.5 prior to reaching the proposed restricted 70% power level (between 68 and 70 percent rated thermal power). In addition, the licensee plans to submit information with the supplement that will clarify the discussions provided in the LAR submittals.
The clarification call was held at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland.
Docket No. 50-361
ML13094A077), related to the licensees October 3, 2012 confirmatory action letter response. In particular, the NRC staff sought clarification concerning procedural changes for the power dependent Technical Specification Surveillance Requirements (SRs) 3.2.2.1, 3.2.3.3, 3.3.1.2, 3.3.1.5, and 3.3.1.11.
The licensee confirmed for the NRC staff that, although SRs 3.2.2.1, 3.2.3.3, and 3.3.1.11 are power dependent, their performance would not be impacted by the proposed restricted 70%
power, and the procedural changes are intended to ensure they will be performed at or before the required frequency. The licensee also indicated that it planned to supplement the LAR with additional license conditions to more clearly demonstrate that it will perform SRs 3.3.1.2 and 3.3.1.5 prior to reaching the proposed restricted 70% power level (between 68 and 70 percent rated thermal power). In addition, the licensee plans to submit information with the supplement that will clarify the discussions provided in the LAR submittals.
The clarification call was held at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland.
Docket No. 50-361 DISTRIBUTION:
PUBLIC RidsAcrsAcnw_MailCTR Resource RidsNrrDorl Resource RidsNrrDorlLpl4 Resource RidsNrrLAJBurkhardt Resource RidsNrrPMSanOnofre Resource RidsRgn4MailCenter Resource SBahadur, NRR BBenney, NRR ADAMS Accession No.: ML13122A145
- via email OFFICE NRR/DORL/LPSO/PM NRR/DORL/LPSO/LA NRR/DORL/LPSO/BC NRR/DORL/LPSO/PM NAME BBenney JBurkhardt*
DBroaddus BBenney DATE 5/8/13 5/2/13 5/8/13 5/9/13