| title = Special Rept 2-SR-87-027:on 871009,high Range Noble Gas Monitor Inoperable for Greater than 72 H.Caused by Malfunctioning of RU-143 Smic Display Board.Display Board Replaced
| title = Special Rept 2-SR-87-027:on 871009,high Range Noble Gas Monitor Inoperable for Greater than 72 H.Caused by Malfunctioning of RU-143 Smic Display Board.Display Board Replaced
| author name = HAYNES J G
| author name = Haynes J
| author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
| author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
| addressee name =  
| addressee name =  

Revision as of 20:55, 18 June 2019

Special Rept 2-SR-87-027:on 871009,high Range Noble Gas Monitor Inoperable for Greater than 72 H.Caused by Malfunctioning of RU-143 Smic Display Board.Display Board Replaced
ML17303A676
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 11/05/1987
From: Haynes J
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
2-SR-87-027, 2-SR-87-27, NUDOCS 8711120157
Download: ML17303A676 (4)


Text

REGULA RY INFORMATION DISTRIBUTI SYSTEM (RIDS)ACCESSION NBR: 8711120157 DOC.DATE: 87/11/05 NOTARIZED:

NO'OCKET FACIL: STN-50-529 Palo VeT de Nuclear Stations Unit 2i Arizona Publi 05000529 AUTH.NAME AUTHOR AFFILIATION HAYNESI J.G." Arizona Nuclear Power ProJect (formerly Arizona Public Serv REC IP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk>

SUBJECT:

Special Rept 2-SR-87-027:

on 871009'igh range noble gas monitor inoperabl'e for greater than 72 h.Caused by malfunctioning of RU-143 SMIC display board.Display board rep laced.DISTRIBUTION CODE: IE22D COPIES RECEIVED: LTR Q ENCL g SIZE: TITLE: 50.73 Licensee Event Report (LER)~Incident Rpti etc.NOTES: Standardized plant.05000529 REC IP IENT ID CODE/NAME PD5 LA LICITRAz E INTERNAL: ACRS MICHELSON AEQD/DQA AEQD/DSP/RQ*B ARM/DCTS/DAB NRR/DEST/ADS NRR/DEST/ELB NRR/DEBT/MEB NRR/DEBT/PSB NRR/DEST/SGB NRR/DLPG/GAB NRR/DREP/RAB S/SIB REG FILE 02 GRDCE J RGN5 FILE 01 EXTERNAL: EG5G GROHi M LPDR NSIC HARRIS'COPIES LTTR ENCL 1 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5 5 1 1 1 RECIPIENT ID CODE/NAME PD5 PD DAVISi M ACRS MOELLER AEOD/DSP/NAS AEOD/DSP/TPAB DEDRO NRR/DEST/CEB NRR/DEST/ICSB NRR/DEBT/MTB NRR/DEST/RSB NRR/DLPG/HFB NRR/DQEA/EAB NRR/DREP/RPB NRR/PMAS/ILRB RES DEPY GI RES/DE/EIB H ST LOBBY WARD NRC PDR NSIC MAYST G COPIES LTTR ENCL 1, 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 NOTES: TOTAL NUMBER QF COPIES REQUIRED: LTTR 47 ENCL 46 Arizona Nuclear Power Project P.O.SOX 52034~PHOENIX.ARIZONA 85072-2034 192-00308-JGH-TRB/KCP November 5, 1987 U.S.Nuclear Regulatory Commission NRC Document Control Desk Washington, D.C.20555

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)Unit 2'ocket No.STN 50-529 (License NPF-51)Special Report 2-SR-87-027 File: 87-020-404 Attached please find Special Report 2-SR-87-027 prepared and submitted pursuant to Technical Specifications 3.3.3.8 and 6.9.2.This report discusses a radiation monitor that was inoperable for greater than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.If you have any questions, please contact T.R.Bradish, Compliance Supervisor at (602)393-3531.Very truly yours, VI" J.G.H ynes Vice President Nuclear Production JGH/TRB/KCP/cld Attachment cc: 0.M.DeMichele (all w/a)E.E.Van Brunt, Jr.J.B.Martin J.R.Ball E.A.Licitra A.C.Gehr INPO Records Center 87iil201S7 87ii05 PDR ADOCK 05000M9 S PDR

PALO VERDE NUCLEAR GENERATING STATION RADIATION MONITORING UNIT INOPERABLE FOR GREATER THAN 72 HOURS License No.NPF-51 Docket No.STN 50-529 Special Report No.2-SR-87-027 This Special Report is being submitted in accordance with Technical Specification (T.S.)3.3.3.8 ACTION 42 (b)and 6.9.2 to report an event in which a high range noble gas monitor was inoperable for greater than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> limit for inoperability was exceeded at approximately 1010 MST on October 9, 1987.At approximately 1010 MST on October 6, 1987, the Plant Vent Low and High Range Monitors (RU-143/144) were declared inoperable to permit surveillance testing in accordance with 36ST-9SQ04,"Radiation Monitoring Quarterly Functional Test." As a prerequisite to testing, rework was required for a faulty display on the skid mounted indicator and control unit (SMIC)for RU-143.Compensatory measures were established in accordance with the applicable requirements of T.S.3.3.3.8, ACTIONS 36, 37, 40 and 42.Monitors RU-143 and RU-144 monitor the plant vent exhaust for particulate, iodine and gaseous activity.The monitors work as a pair, with RU-143 as the low range monitor and RU-144 as the high range monitor.Normal configuration consists of RU-143 operating with RU-144 in standby.When RU-143 reaches its maximum range, RU-144 starts and RU-143 goes to standby.RU-143 and RU-144 are required to be operable at all times.Since the monitors operate in tandem, RU-144 must be declared inoperable if RU-143 is inoperable.

Subsequent evaluation revealed that the RU-143 SMIC display board would not light one of the hexidecimal light emitting diodes (LEDs).The display board was replaced and functionally tested as satisfactory, but RU-143 and RU-144 remained inoperable to support ongoing surveillance testing activities.

These testing activities identified an additional, separate problem in which a defective data relay board on RU-144 prevented the monitor from being placed on-line from the Radiation Monitoring System minicomputer terminal.The data relay board was replaced under an approved work document, and testing resumed.A root cause of the evaluation of the defective SMIC display board and data relay board has been initiated to determine why these components failed.At approximately 1400 MST on October 12, 1987, RU-143 and RU-144 were declared operable after satisfactory completion of surveillance testing.The.duration of this event was approximately 6 days.