Text
ACCELERATED ]+TRIBUTION DEMON~TION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9401040106 DOC.DATE: 93/12/15 NOTARIZED:
NO DOCKET FACIL:STN-50-528 Palo Verde Nuclear Station, Unit 1, Arizona Publi 05000528 AUTH.NAME AUTHOR AFFILIATION LEVIN,J.M.
Arizona Public Service Co. '(formerly Arizona Nuclear Power
.RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Special rept:on 931215,strong motion accelerometer channel of seismic monitoring sys inoperable for more than 30 days.
Caused by single-axis acceleromet'er not responding.
DISTRIBUTION CODE:
IE22D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: 50.73/50.9 Licensee Event Report (LER), Incident Rpt, etc.
D NOTES:STANDARDIZED PLANT 05000528 /
RECIPIENT ID CODE/NAME PDV LA HOLIAN,B COPIES LTTR ENCL 1
1 1
1 RECIPIENT ID CODE/NAME PDV PD TRAN,L COPIES LTTR ENCL 1
1 1
1
~
0 D
INTERNAL: ACRS AEOD/DSP/TPAB
'RR/DE/EELB NRR/DORS/OEAB NRR/DRCH/HICB NRR/J)~I L/RPEB
/DSBA/SPLB
~G~+
02 RGN5 FILE 01 2
2 1
1 1
1 1
1.
1 1
1 1
1 1
1' 1
1 AEOD/DOA AEOD/ROAB/DSP NRR/DE/EMEB NRR/DRCH/HHFB NRR/DRCH/HOLB NRR/DRSS/PRPB NRR/DSSA/SRXB RES/DSIR/EIB 1
2 1
1 1
2 1
1 1
2 1
1 1
2 1
1 EXTERNAL EG &G BRYCE g J ~ H NRC PDR NSIC POOREgW
~
2 2
1 1
1 1
L ST LOBBY WARD NSIC MURPHY,G.A NUDOCS FULL TXT 1
1 1
1 1
1 D
NOTE TO ALL"RIDS" RECIPIENTS:
D D
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOiVI Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 31 ENCL 31
JAMES M. LEVINE VICE PRESIDENT NUCLEAR PRODUCTION Arizona Public Service Company PALO VERDE NUCLEAR GENERATING STATION P.O. BOX 52034
~
PHOENIX, ARIZONA85072-2034 192-00873-JML/TRB/R JR December 15, 1993 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Mail Station P1-37 Washington, D.C. 20555
Dear Sirs:
Subject:
Palo Verde Nuclear Generating Station (PVNGS)
Unit 1 Docket No. STN 50-528 (License No. NPF-41)
Special Report 1-SR-93-007 File: 93-020-404 Enclosed please find Special Report 1-SR-93-007 prepared and submitted pursuant to Technical Specification 3.3.3.3 ACTION (a) and Technical Specification 6.9.2. This report discusses the inoperability of one (1) Seismic Monitoring System accelerometer channel for more than 30 days.
If you have any questions, please contact B. A, Grabo, Supervisor, Nuclear Regulatory Affairs, at (602) 393-6492.
Sincerely, JMLfTRB/RJR/rv Enclosure (all with attachment) cc:
W. F. Conway B. H. Faulkenberry K. E. Johnston INPO Records Center g(IF 9401040106 931215 PDR ADOCK 05000528 S
PALO VERDE NUCLEAR GENERATING STATION UNIT 1
'I Seismic Monitoring System Strong Motion Accelerometer License No. NPF-41 Docket No. 50-528 Special Report 1-SR-93-007 Initial Conditions:
This special report is being submitted pursuant to Techhical Specification (TS) Limiting Condition for Operation (LCO) 3.3.3.3 ACTION (a) and TS 6.9.2 to report an event in which one (1) strong motion accelerometer channel of the Seismic Monitoring System was inoperable for a period greater than 30 days.
This accelerometer is required to be operable at all times to meet the station seismic monitoring requirements of TS LCO 3.3.3.3.
The 30 day period for returning the accelerometer to an OPERABLE condition was exceeded at approximately 0932 MST on December 15, 1993.
.S stem Descri tion:
The Seismic Monitoring System (SM) is installed in Unit 1 (only) and consists of six (6) tri-axial strong motion accelerometer assemblies, associated instrumentation, and recording equipment for measuring plant response to earthquake activity. Each tri-axial strong motion accelerometer assembly consists of three (3) single-axis accelerometers.
All six (6) of the strong motion accelerometer channels are installed with a channel orientated vertical, a channel orientated true East-West, and a channel orientated true North-South. A response spectrum analyzer is provided to compare seismic acceleration response spectra with plant design response spectra to determine if design response spectra are exceeded.
After an earthquake, the decision to continue operating the units or to shut them down is based on an analysis which is performed to determine whether or not the plant seismic Design Bases Response Spectra (DBRS) (i.e., allowable stresses) have been exceeded.
II Cause of Malfunction:
During the performance of Surveillance Test (ST) 36ST-1SM01, the strong motion accelerometer assembly mounted on the Reactor Coolant Pump (RCP) upper end bell did not have an output to the SM cabinet.
Troubleshooting identified that one (1) of the three (3) single-axis accelerometers which make-up this tri-axial channel was not responding.
V
.U. S. Nuclear Regulatory Commission Special Report 1-SR-93-007 Page 2 of 2 Plans for Restoration:
The strong motion accelerometers are Terra Technology, Model SSA-302. The remainder ofthe system is operating properly and willsupply sufficient information to allow detection and evaluation of an earthquake.
The accelerometer that failed is located on an RCP housing and can not be replaced with the unit operating. The complete tri-axial assembly will be replaced during the'next outage of sufficient duration.