 Issue dateTitleTopic
IR 05000483/199901014 October 1999Insp Rept 50-483/99-10 on 990913-16.No Violations Noted. Major Areas Inspected:Plant Support Re Biennial Exercise of Emergency Plan & Procedures
IR 05000483/199901122 September 1999Insp Rept 50-483/99-11 on 990812-20.No Violations Noted. Major Areas Inspected:Operations,Maint & EngineeringShutdown Margin
Grab sample
Maintenance Rule Program
Fire Watch
IR 05000483/199900813 September 1999Insp Rept 50-483/99-08 on 990725-0904.Noncited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant SupportHigh Radiation Area
Stroke time
Control of Heavy Loads
IR 05000483/199900710 September 1999Insp Rept 50-483/99-07 on 990809-13.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program to Determine Whether Program Incorporated Appropriate Requirements for Evaluating OperatorsJob Performance Measure
PNO-IV-99-035A, on 990810,heater Drain Line Pipe Rupture Occurred.Caused by Flow Accelerated Corrosion in Conjunction with Moisture Impingement.Licensee Has Completed Replacement of Damage Heater Drain Piping & Conducted Insps of Piping18 August 1999PNO-IV-99-035A:on 990810,heater Drain Line Pipe Rupture Occurred.Caused by Flow Accelerated Corrosion in Conjunction with Moisture Impingement.Licensee Has Completed Replacement of Damage Heater Drain Piping & Conducted Insps of Piping
IR 05000483/199900613 August 1999Insp Rept 50-483/99-06 on 990613-0724.One Severity Level 4 Violation Noted & Being Treated as Ncv.Major Areas Inspected:Operations,Maint & Plant SupportBoric Acid
PNO-IV-99-035, on 990810,operators Initiated Manual Rt When High Pressure Heater Drain Line Ruptured in Turbine Bldg. Licensee Is Evaluating Options for Facilitating Repair & Restarting Plant.Region IV Will Conduct Special Insp11 August 1999PNO-IV-99-035:on 990810,operators Initiated Manual Rt When High Pressure Heater Drain Line Ruptured in Turbine Bldg. Licensee Is Evaluating Options for Facilitating Repair & Restarting Plant.Region IV Will Conduct Special Insp
IR 05000483/199900525 June 1999Insp Rept 50-483/99-05 on 990502-0612.Two Violations Noted & Being Treated as Noncited Violations.Major Areas Inspected: Operations,Maint,Engineering & Plant SupportHigh Radiation Area
Past operability
Enforcement Discretion
Nondestructive Examination
IR 05000483/199900319 May 1999Insp Rept 50-483/99-03 on 990321-0501.Noncited Violation Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant SupportShutdown Margin
High Radiation Area
Operability Determination
Through-Wall Leak
IR 05000483/19993023 May 1999Exam Rept 50-483/99-302 on 990416.Exam Results:Ro License Applicant Passed Retake Written Exam & Test Matl Adequate
IR 05000483/19990015 April 1999Insp Rept 50-483/99-01 on 990207-0320.One Violation Occurred & Being Treated as Noncited Violation.Major Areas Inspected: Operations,Maint,Engineering & Plant SupportHigh Radiation Area
Ultimate heat sink
Missed surveillance
IR 05000483/19993012 February 1999NRC Operator Licensing Exam Rept 50-483/99-301 for Exams Administered on 990111-15Job Performance Measure
ML20199D92612 January 1999Notice of Violation from Insp on 981115-1226.Violation Noted:Licensee Failed to Perform Written Safety Evaluation, from 840611-980505
IR 05000483/19980184 December 1998Insp Rept 50-483/98-18 on 980914-1002.Violations Noted. Major Areas Inspected:Review of Design & Licensing Basis for Essential Service Water Sys,Associated Electrical Support Sys & Review of Program Implement 10CFR50.59Unanalyzed Condition
Ultimate heat sink
Stroke time
Past operability
Temporary Modification
Operability Determination
Frazil ice
Maintenance Rule Program
Weak link
ML20198A1234 December 1998Notice of Violation from Insp on 980914-1002.Violation Noted:Listed Activities Affecting Quality Either Not Prescribed by Documented Instructions Appropriate to Circumstances or Not Accomplished with Procedures
PNO-IV-98-059, on 981129,licensee Commenced Plant Shutdown from 100% Power to Mode 3 to Replace Fan Motor.Resident Inspector Monitored Portion of Plant Shutdown from Cr.Info Has Been Discussed with Licensee30 November 1998PNO-IV-98-059:on 981129,licensee Commenced Plant Shutdown from 100% Power to Mode 3 to Replace Fan Motor.Resident Inspector Monitored Portion of Plant Shutdown from Cr.Info Has Been Discussed with Licensee
IR 05000483/199802425 November 1998Insp Rept 50-483/98-24 on 981026-30.Violation Noted.Major Areas Inspected:Licensee Implementation of NRC Approved Fire Protection ProgramHot Short
Safe Shutdown
Fire Barrier
Emergency Lighting
Fire Protection Program
Fire Watch
Hourly Fire Watch
Weak link
ML20196G34725 November 1998Notice of Violation from Insp on 981026-30.Violation Noted: on 981030,control Room Pantry Fire Door,Identified as Being Nonfunctional Without Fire Barrier Impairment Permit or Conpensatory Actions,As Required by Procedure APA-ZZ-00701Fire Barrier
Continuous fire watch
Fire Protection Program
Hourly Fire Watch
IR 05000483/199802225 November 1998Insp Rept 50-483/98-22 on 980927-1114.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant SupportShutdown Margin
High Radiation Area
Ultimate heat sink
Past operability
Missed surveillance
IR 05000483/199802328 October 1998Insp Rept 50-483/98-23 on 981013-15.No Violations Noted. Major Areas Inspected:Operational Status of License Emergency Preparedness Program Was Conducted
IR 05000483/199801526 October 1998Insp Rept 50-483/98-15 on 980706-10.No Violations Noted. Major Areas Inspected:Guidance of Temporary Instruction 2515/137, Insp of Medium-Voltage & Low-Voltage Power Circuit BreakersCommercial Grade Dedication
Maintenance Rule Program
IR 05000483/199802015 October 1998Insp Rept 50-483/98-20 on 980817-0904.No Violations Noted. Major Areas Inspected:Operations & MaintCoatings
Condition Adverse to Quality
Systematic Assessment of Licensee Performance
IR 05000483/19980219 October 1998Insp Rept 50-483/98-21 on 980816-0926.No Violations Noted. Major Areas Inspected:Operations,Maint & EngineeringHigh Radiation Area
IR 05000483/199801929 September 1998Insp Rept 50-483/98-19 on 980914-18.No Violations Noted. Major Areas Inspected:Plant SupportHigh Radiation Area
IR 05000483/199801221 August 1998Insp Rept 50-483/98-12 on 980705-0815.No Violations Noted. Major Areas Inspected:Operations,Maint & Plant SupportPacking leak
High Radiation Area
Ultimate heat sink
ML20237B89314 August 1998Notice of Violation from Insp on 980803-07.Violation Noted: on 980804,inspector Noted Three Containers of Dry Active Waste Stored within 10 Feet of Permanent Structure
IR 05000483/199801714 August 1998Insp Rept 50-483/98-17 on 980803-07.Violations Noted.Major Areas Inspected:Implementation of Solid Radioactive Waste Mgt & Radioactive Matls Transportation ProgramOffsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
Process Control Program
IR 05000483/19980166 August 1998Insp Rept 50-483/98-16 on 980713-17.No Violations Noted. Major Areas Inspected:Plant SupportGrab sample
Offsite Dose Calculation Manual
Annual Radiological Environmental Operating Report
IR 05000483/199801329 July 1998Insp Rept 50-483/98-13 on 980714-17.Violation Noted.Major Areas Inspected:Engineering & Plant SupportOffsite Dose Calculation Manual
Annual Radioactive Effluent Release Report
ML20236V32529 July 1998Notice of Violation from Insp on 980714-17.Violation Noted: Grinding Needle Gun Work Performed on 2,000 Ft Elevation of Cb Liner Floor Plate W/O Performing Surveys to Evaluate Concentration or Quantities of Radioactive Matl
IR 05000483/199801417 July 1998Insp Rept 50-483/98-14 on 980629-0702.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness ProgramGrace period
IR 05000483/19980118 July 1998Insp Rept 50-483/98-11 on 980524-0704.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant SupportShutdown Margin
Packing leak
High Radiation Area
Ultimate heat sink
ML20248L2628 June 1998Notice of Violation from Insp on 980412-0523.Violation Noted:On 980419,workman Protection Assurance 26226 Was Inadequate to Ensure Safety During Work on Valve EJHV8804A
IR 05000483/19980088 June 1998Insp Rept 50-483/98-08 on 980412-0523.Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant SupportHigh Radiation Area
Ultimate heat sink
Foreign Material Exclusion
IR 05000483/199800719 May 1998Insp Rept 50-483/98-07 on 980427-0501.Violations Noted.Major Areas Inspected:Radiation Protection Program Focussing on Refueling Outage ActivitiesHigh Radiation Area
ML20247M22419 May 1998Insp Rept 50-483/98-10 on 980428-30.No Violations Noted. Major Areas Inspected:Contingency Plan Developed in Response to Insp Findings in NRC Insp Rept 50-483/98-06 W/Special Emphasis on Training Process Used to Qualify People for Er
IR 05000483/199800919 May 1998Insp Rept 50-483/98-09 on 980428-30.No Violations Noted. Major Areas Inspected:Maint & Plant SupportNon-Destructive Examination
Anchor Darling
Nondestructive Examination
VT-2
Liquid penetrant
Scaffolding
IR 05000483/19980058 May 1998Insp Rept 50-483/98-05 on 980413-0501.No Violations Noted. Major Areas Inspected:Maintenance,Engineering & Plant SupportNondestructive Examination
ML20217F48822 April 1998Insp Rept 50-483/98-06 on 980324-26.Violations Noted.Major Areas Inspected:Plant Support
ML20217F44922 April 1998Notice of Violation from Insp on 980324-26.Violations Noted: on 970529,licensee Made Changes to Emergency Plan W/O Commission Approval,That Decreased Effectiveness of Plan & Did Not Continue to Meet Planning Standard 50.47(b)(2)
IR 05000483/199800317 April 1998Insp Rept 50-483/98-03 on 980301-0411.No Violations Noted. Major Areas Inspected:Operations,Maint & EngineeringHigh winds
High Radiation Area
Time to boil
Fire Watch
Scaffolding
IR 05000483/199800417 April 1998Insp Rept 50-483/98-04 on 980406-10.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program
IR 05000483/199800226 March 1998Insp Rept 50-483/98-02 on 980202-06.Violation Noted.Major Areas Inspected:Maint,Engineering Re Bldg Emergency Filter Sys AdsorberEnforcement Discretion
ML20217F19226 March 1998Notice of Violation from Insp on 980202-06.Violation Noted: Licensee Did Not Demonstrate That Either Train of Auxiliary Fuel Bldg Emergency Filter Sys Adsorbers Could Comply W/Ts 4.7.7.b.2 Until Charcoal from Each Train Was Replaced
ML20216A7979 March 1998Notice of Violation from Insp on 980118-0228.Violation Noted:On 980216,instructions to Work Authorization C612323 Did Not Provide Adequate Guidance for Concrete Core Drilling Work,As Result,Licensee Personnel Drilled Into Power Cable
IR 05000483/19980019 March 1998Insp Rept 50-483/98-01 on 980118-0228.Violations Noted. Major Areas Inspected:Operations,Engineering & Plant SupportHigh Radiation Area
Ultimate heat sink
Enforcement Discretion
Temporary Modification
IR 05000483/199702127 January 1998Insp Rept 50-483/97-21 on 971207-980117.No Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant SupportBoric Acid
Packing leak
High Radiation Area
Ultimate heat sink
IR 05000483/199802512 January 1998Insp Rept 50-483/98-25 on 981115-1226.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support,Including Health Physics & SecurityBoric Acid
High Radiation Area
Past operability
IR 05000483/199701918 December 1997Insp Rept 50-483/97-19 on 971117-1211.No Violations Noted. Major Areas Inspected:EngineeringBoric Acid
Shutdown Margin
Fuel cladding
IR 05000483/199702016 December 1997Insp Rept 50-483/97-20 on 971026-1206.Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant SupportBoric Acid
High Radiation Area
Ultimate heat sink