Issue date | Title | Topic | |
---|---|---|---|
ML20196H011 | 11 July 1997 | Special Rept 97-001:on 970620,removed High Range Radioactive Noble Gas Effluent Monitor (Stack Ragems) from Service to Allow Secondary Calibr IAW Master Surveillance Schedule. Completed Calibr on 970628 & Returned Stack Ragems to Svc | |
ML20129A340 | 15 October 1996 | Special Rept 96-001,rev 1:on 960806,stack Ragems High Range Monitor Was Removed from Svc & Not Restored to Svc in Seven Days.Caused by Malfunction of Interlock on Source. Interlock Components Replaced | |
ML20117K593 | 5 September 1996 | Special Rept SR 96-001:on 960806,declared Stack Ragems High Range Monitor Inoperable.Caused by Difficulties Requiring Component Replacement.Developed Course of Action for Returning Stack Ragems Instrument | |
ML20116B752 | 27 October 1992 | Special Rept 92-08:on 920929,Turbine Building High Radiation Noble Gas Monitor Declared Inoperable for Greater than Seven Days.Alternate Testing Performed Throughout Period of Inoperability | Grab sample |
ML20115G646 | 22 October 1992 | Special Rept 92-07:on 921015,determined That Stem & Disc Separated on Discharge Valve V-9-004 for Diesel Fire Pump P-9-102A.On 921021,fire Pumps Isolated.Redundant Fire Pump Secured & Valves Replaced | |
ML20105A512 | 10 September 1992 | Special Rept 92-06:on 920807,fire Diesel Pump 1 Declared Inoperable for More than 7 Days to Perform Preventive Maint.On 920811,diesel Engine Overheated.Solenoid Valve Replaced & New Cooling Water Strainers Installed | |
ML20104B608 | 10 September 1992 | Special Rept 92-05:on 920727,condenser Bay Sprinkler Sys 2 Removed from Svc After Spurious Actuation of Sprinkler Head. Hourly Fire Watch Established While Sys Out of Svc.Sprinkler Head Replaced & Sys Returned to Svc on 920814 | Hourly Fire Watch Scaffolding |
ML20114C519 | 26 August 1992 | Special Rept 92-03:on 920705,electromatic Relief Valve C Inadvertently Opened While Testing Pressure Switch of Valve A.Caused by Personnel Error.Training Session Will Be Held & Engineering Work Request Submitted Re Switch Terminal Point | |
ML20114A970 | 17 August 1992 | Special Rept 92-04:on 920724,fire Diesel Pump 2 Removed from Svc to Replace Battery Cables & Solenoid Valve.Correct 24 Volt Dc Coil Obtained from Mfg & Pump Returned to Svc on 920806 | |
ML20096D471 | 1 May 1992 | Special Rept 92-02:on 920327,fire Diesel Pump 1 Out of Svc for More than 7 Days to Replace Pump Due to Marginal Discharge Pressure.Caused by Valve Seating Problem.Pump Replacement Expected to Be Completed by 920504 | |
ML20100R741 | 10 April 1992 | Special Rept 92-01:on 920227,CO2 Fire Suppression Sys for 4,160-volt Switchgear Inoperable for More than 14 Days When Leaking Valve Stem Repaired on 920226.Possibly Caused by Moisture Intrusion.Corroded Components Replaced | |
ML20087B843 | 3 January 1992 | Special Rept 91-09:on 911115,fire Diesel Pump 1-2 Failed to Meet Required Acceptance Criteria During Functional Test. Caused by Cloth Rag Becoming Lodged Inside Pump.Fire Diesel Pump 1-2 Rebuilt & Reinstalled on 911208 | |
ML20076E264 | 13 August 1991 | Special Rept 91-08:on 910717,coolant Found Leaking from Cap on Heat Exchanger of Engine of Fire Diesel Pump 1-1.Caused by Wearing on HX Neck,Resulting in HX Failing to Hold Normal Pressure.Engine Secured & Work Request Initiated | |
ML20076E300 | 12 August 1991 | Special Rept 91-07:on 910709,nonfunctional Fire Barrier Doors Between Fire Zones OB-FA-6 & TZ-FZ-11B Not Restored to Operable Status within 7 Days.Caused by Ventilation Flow Preventing Door from Closing.Fire Patrol Established | Fire Barrier Fire Watch |
ML20077K227 | 31 July 1991 | Special Rept 91-06 Re Nonfunctional Fire Barrier Door Not Repaired within 7 Days as Required by Tech Spec 3.12.E. Caused by Broken Door Closure Mechanism.Hourly Fire Watch Initiated.Door Mechanism Repaired on 910704 | Fire Barrier Fire Watch Hourly Fire Watch |
ML20082E141 | 23 July 1991 | Special Rept:On 910702,non-functional Fire Barrier Door Not Repaired within Seven Days as Required by Tech Specs. Caused by Faulty Door Closing Mechanisms.Util Evaluating Alternate Door Closing Mechanisms | Fire Barrier Fire Watch Hourly Fire Watch |
ML20073C938 | 18 April 1991 | Special Rept 91-04:on 910309,fire Detection Sys on Elevations 75' & 95' of Reactor Bldg Made Inoperable to Facilitate Maint Activities.Fire Watch Patrol Has Been Established to Compensate for Detection Sys | Fire Watch |
ML20070T534 | 28 March 1991 | Special Rept:On 910222,inoperable Fire Hose Station 33 Not Restored to Operable Status within 14 Days as Required by Tech Specs.Caused by Maint to Angle Valve.Valve Reopened on 910312,restoring Hose Station 33 to Operability | |
ML20070M518 | 14 March 1991 | Special Rept 91-02:on 901117,discovered That Fire Barrier Door Between 480-volt Switchgear Rooms a & B Nonfunctional Since 901110 & Not Repaired within 7 Days.Caused by Faulty Door Latching Mechanism.Fire Watch Established | Fire Barrier Fire Watch |
ML20058A744 | 16 October 1990 | Special Rept 90-04:on 900921,nonfunctional Fire Barrier Door Not Repaired within 7 Days.Fire Watch Established | Fire Barrier Fire Watch |
ML20245E754 | 9 June 1989 | Special Rept 89-02:on 890526,declared Fire Pump/Diesels 1-1 & 1-2 Inoperable.Caused by Loss of Fire Suppression Water. Pressure Switch & Associated Recorder for 1-2 Diesel Recalibrated Along W/Pump Discharge Pressure Gauge | |
ML20247J208 | 22 May 1989 | Special Rept 89-01:on 890422,nonfunctional Fire Barrier Not Repaired within 7 Days as Required by Tech Spec 3.12.E. Fire Watch Established.Nonfunctional Fire Barrier Seal Plannned to Be Restored to Operable Status by 890523 | Fire Barrier Fire Watch |
ML20237C671 | 11 December 1987 | Special Rept 87-08:on 871112,fire Diesel Pump 1-2 Not Restored to Functional Status within 7 Days.Caused by Constraints Imposed by Increased outage-related Maint Activities.Fire Diesel Pump Restored to Functional Status | |
ML20236S520 | 19 November 1987 | Special Rept 87-07:on 871020,nonfunctional Thermo Lag Fire Barrier Not Restored to Functional Status within 7 Days Per Tech Spec 3.12.E.Caused by Constraints Imposed by Increased Maint Activities.Fire Watch Established | Fire Barrier Fire Watch |
ML20236L371 | 29 October 1987 | Special Rept 87-06:on 870928-30,fire Barrier Penetration Seals Identified as Not Meeting Acceptance Criteria.Cause Not Stated.Fire Watch Established Immediately.Fire Barrier Seals Will Be Restored to Functional Status by 871030 | Fire Barrier Fire Watch |
ML20235B441 | 22 September 1987 | Ro:On 870811,spill of Reactor Bldg Closed Cooling Water Occurred.Caused by Failure to Follow Instructions on Switching & Tagging Request Form Re Valve Backseating. Procedures Will Be Revised & Training Provided | |
ML20235G215 | 20 September 1987 | Ro:On 870911,w/reactor in Cold Shutdown Mode,Tech Spec Safety Limit 2.1.E Exceeded.Caused by Operator Error. Operators Received Training on Safety Limit,Applicable Procedures & Relevant Control Room Indications | |
ML20214H980 | 7 May 1987 | Ro:On 870424,operator Personnel Blocked Open Two Torus to Drywell Vacuum Breaker Valves at Time When Primary Containment Integrity Was Required.Caused by Cognitive Personnel Error.Procedures Revised | |
ML20215H362 | 9 April 1987 | Special Rept 87-02:on 870214,turbine Trip & Reactor Scram Occurred.Caused by Loose Wire Causing Loss of Feedwater Flow Signal.Following Reduction in Reactor Pressure All Electromatic Relief Valves Reseated Properly | |
ML20206E393 | 1 April 1987 | Special Rept 87-01:on 870302,inoperable Fire Suppression Water Deluge Sys Not Restored to Functional Status within 14 Days from Time of Discovery.Caused by Long Lead Time for Procurement of Replacement Parts | Time of Discovery Hourly Fire Watch |
ML20209H250 | 23 January 1987 | Special Rept 86-017:on 861228,nonfunctional Fire Barrier Not Returned to Functional Status within 7 Days from Discovery.Hourly Fire Watch Established.Repairs Completed & Penetration Seal Restored to Functional Status on 870112 | Time of Discovery Fire Barrier Hourly Fire Watch |
ML20207J298 | 17 December 1986 | Special Rept 86-16:on 861121,fire Barrier Door Between Monitor & Control Area Stairwell & Hallway Outside Cable Spreading Room Found Nonfunctional.Hourly Fire Watch Patrol Established.Door to Be Restored as Functional on 861222 | Time of Discovery Fire Barrier Hourly Fire Watch |
ML20207J282 | 16 December 1986 | Special Rept 86-15:on 861110,penetrations Through Floor of 4160 Volt Switchgear 1D Vault & Floor of Motor Generator Set Room Found Degraded.As of 861117,penetrations Not Restored to Functional Condition.Hourly Fire Watch Patrol Initiated | Time of Discovery Fire Barrier Hourly Fire Watch |
ML20197B147 | 9 October 1986 | Special Rept 86-14:on 860922 & 27,nonfunctional Fire Barrier Penetration Seals Not Restored to Functional Status within 7 Days.Hourly Fire Watch Patrol Established within 1 H. Restoration Expected by 861130 | Time of Discovery Fire Barrier Hourly Fire Watch |
ML20212D625 | 10 July 1986 | Special Rept 86-03:on 860616,two Hangers Supporting Ofc Bldg Fire Water Supply Riser Found to Need Repair.Riser Consequently Isolated,Rendering Sprinkler Sys 4 & 12 & Deluge Sys 4 Inoperable.Hangers Repaired & Sys Restored | Fire Watch Hourly Fire Watch |
ML20137U703 | 20 January 1986 | Fire Protection Special Rept 85-03:on 851216,insp of 14 Fire Dampers Identified Design or Installation Deficiencies Resulting in Dampers Being Determined Inoperable.Caused by Nonconforming as-found Fire Damper Configuration | Fire Barrier Hourly Fire Watch |
ML20117C745 | 25 April 1985 | Special Rept 85-02:on 850225,electromatic Relief Valves NR-108B,NR-108C & NR-108D Failed to Fully Reseat After Initial Actuation,Per Tech Spec 6.9.3.f.Caused by Valve Design Deficiency.Design Change Considered | |
ML20102B867 | 21 February 1985 | Special Rept 85-01:on 850207,leakage Observed Around post-indication Valve V-9-13.Fire Suppression Water Sys Isolated on 850211 to Facilitate Valve Repair.Caused by Crack in Valve Body.Valve Replaced | Nondestructive Examination |
ML20092N635 | 15 June 1984 | Special Rept 84-01:on 840606,post-indicating Valve V-9-12 Branching Off 14-inch Fire Water Main Damaged by Maint Vehicle,Resulting in Loss of Fire Suppression Water Sys. Caused by Lack of Protection Against Physical Damage | |
ML20083C645 | 8 December 1983 | RO 83-02T:on 831119,w/fire Pump 1-1 Out of Svc,Fire Pump 1-2 Failed to Start on Low Sys Pressure.Caused by Impeller Wear Rings Out of Tolerance on High End of Clearance Limits. Overspeed Trip Reset | |
ML20082R655 | 21 November 1983 | RO 83-02:on 831119,fire Pump 1-2 Failed to Start on Low Sys Pressure During Demand for Fire Water to Fill Isolated Portion of Underground Fire Suppression Pool.Caused Suspected to Be Faulty Overspeed Trip Switch.Switch Tested | |
ML20082L149 | 18 November 1983 | Followup RO 83-01:on 831103,fire Suppression Water Sys Declared Inoperable After Pump 1-1 Failed Testing.Mod Underway to Install New Pressure Relief Valves on Both Fire Pumps | |
ML20082B792 | 4 November 1983 | RO 83-01:on 831103,fire Suppression Water Sys Declared Inoperable Due to Smoke Emitting from Under Fire Pump 1-2 Pumphead During post-maint Inservice Test & Failed Design Rated Curve for Pump 1-1.Caused by Misadjusted Impeller | |
ML20082L572 | 15 September 1983 | Advises That Followup to RO 83-17 Re Diesel Generator Fast Start Surveillance Will Be Forwarded by 830921 | |
ML20073A707 | 23 March 1983 | RO 83-4:on 830211,during Controlled Reactor Shutdown,One Dilution Pump Remained in Svc When Intake Canal Water Below Tech Spec Limit.Caused by Personnel Error.Procedures Will Be Revised to Provide More Explicit Directions | |
ML20071B091 | 14 February 1983 | RO 83-1-1:on 830113,dilution Pump 1-2 Removed from Svc. Caused by Insufficient Seal Water flow.Long-term Corrective Action Includes Program Designed to Improve Pump Reliability | |
ML20071B095 | 14 February 1983 | RO 83-2-1:on 830118,dilution Pump 1-1 Removed from Svc Due to Steam Around Flax Packing Gland.Caused by Wearing in of New packing.Long-term Corrective Actions Include Upgrading Dilution Pump Seal | |
ML20071B102 | 14 February 1983 | RO 83-3-1:on 830123,dilution Pumps 1-2 & 1-3 Tripped Off. Caused by Failed Electrical Terminations (Stress Cones). Terminations Replaced | |
ML20070P836 | 11 January 1983 | RO 82-8-2:on 821205,dilution Pump 1-3 Tripped,Leaving Dilution Pump 1-2 in Operation.Seal Water Pump Failed & Ambient Water Temp Fell Below Tech Spec Limit.Cause Unknown. Total Dilution Pump Refurbishment Program Initiated | |
ML20064E727 | 21 December 1982 | RO 82-7:on 821201,dilution Pump 1-3 Removed from Svc.Caused by Mud & Debris Clogging Grates,Blocking Water Flow to Dilution Pump.Mud & Debris Removed.Total Dilution Pump Refurbishment Program Planned |