Letter Sequence RAI |
|---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance, Acceptance
- Supplement, Supplement, Supplement
|
MONTHYEARML22101A2002022-03-31031 March 2022, 5 April 2022 TRISO-X, LLC Fuel Fabrication Facility License Application Submittal Project stage: Request ML22101A2052022-04-0505 April 2022 TRISO-X, LLC Fuel Fabrication Facility License Application Submittal Project stage: Other ML22166A0432022-08-0909 August 2022 Enclosure 1 - Requests for Supplement Information for the TRISO-X License Application Review Project stage: Other ML22166A0422022-08-0909 August 2022 Cover Letter - NRC Requests for Supplemental Information (Rsis) for TRISO-X License Application Project stage: Other ML22166A0412022-08-0909 August 2022 NRC Request for Supplemental Information for the TRISO-X License Application Project stage: Request ML22266A2692022-09-23023 September 2022 TRISO-X Fuel Fabrication Facility Environmental Report Submittal Project stage: Request ML22286A1442022-10-13013 October 2022 Response to Requests for Supplemental Information for the Acceptance Review of the TRISO-X Fuel Fabrication Facility License Application Submittal Project stage: Request ML22286A1472022-10-13013 October 2022 Responses to Requests for Supplemental Information to Support the TRISO-X License Application Project stage: Supplement ML22308A2512022-11-0404 November 2022 Triso-X, LLC, License Application and ISA Summary Changes Associated with Responses to Requests for Supplemental Information for the Acceptance Review of the TRISO-X Fuel Fabrication Facility License Application Submittal Project stage: Request ML22320A5632022-11-16016 November 2022 Triso-X, LLC - Additional Information Supporting the Response to Rsi Question 8.1 Concerning the Acceptance Review of the TRISO-X Fuel Fabrication Facility License Application Project stage: Other ML22320A1102022-11-18018 November 2022 NRC Acceptance of the TRISO-X, LLC - Application for a Fuel Fabrication Facility Project stage: Acceptance Review ML22348A0162022-12-16016 December 2022 Enclosure 1 - Observations Developed During the Acceptance Review to Support the TRISO-X Application for a Fuel Fabrication Facility (Public) Project stage: Acceptance Review ML22348A0142022-12-16016 December 2022 Cover Letter - Nuclear Regulatory Commission Observations to Support the TRISO-X License Application for a Fuel Fabrication Facility Project stage: Other ML22348A0132022-12-16016 December 2022 NRC Observations Developed During the Acceptance Review of the TRISO-X License Application Project stage: Request ML23104A4192023-04-14014 April 2023 TRISO-X, LLC, Response to Requests for Additional Information on the Environmental Report for the Proposed Fuel Fabrication Facility Project stage: Request ML23127A0122023-05-31031 May 2023 Request for Additional Information (Set 1) for the Triso-X, LLC License Application for a Fuel Fabrication Facility (Enterprise Project Identification Number L-2022-NEW-0005) Project stage: RAI ML23127A0112023-05-31031 May 2023 Triso-X RAIs for License Application Project stage: Request ML23127A0132023-05-31031 May 2023 Enclosurai for the TRISO-X Application Project stage: RAI ML23198A2592023-07-27027 July 2023 Request for Additional Information for the Triso-X, LLC License Application for a Fuel Fabrication Facility (Enterprise Project Identification Number L-2022-NEW-0005) Project stage: RAI ML23198A2572023-07-27027 July 2023 NRC Letter Request for Additional Information on Chp 1, 2, EP for the TRISO-X, LLC License Application Project stage: Request ML23209A8212023-07-28028 July 2023 Response to Request for Additional Information (Set 1) for the TRISO-X, LLC License Application for a Fuel Fabrication Facility Project stage: Response to RAI ML23230B2002023-08-18018 August 2023 Triso-X, LLC, Supplemental Response to Request for Additional Information Question 3-2 (Set 1) for the TRISO-X License Application Project stage: Supplement ML23237B4842023-08-25025 August 2023 Response to Request for Additional Information (Set 2) for the TRISO-X License Application Project stage: Response to RAI ML23230B1912023-08-28028 August 2023 Cover Letter - RAI Set 3 for the ISA Summary (Programmatic) and Security Regarding TRISO-X License Application Project stage: RAI ML23254A3812023-09-29029 September 2023 Letter to Triso-X for the Fourth Set of RAIs That Includes an Enclosure for Geotechnical and an Enclosure for Hydrology Project stage: Request ML23285A3442023-10-12012 October 2023 Response to Request for Additional Information Set 3 (ISA and Security) for the TRISO-X License Application Project stage: Response to RAI ML23265A2622023-10-25025 October 2023 Request for Additional Information Set 5 for the Radiological and Chemical Review Regarding the TRISO-X, LLC License Application for a New Fuel Fabrication Facility (Enterprise Project Identification Number L-2022-NEW-0005 Project stage: RAI ML23312A3382023-11-0808 November 2023 Response to Request for Additional Information (Set 4) for the TRISO-X License Application Project stage: Response to RAI ML23312A2482023-11-0808 November 2023 7-5-23 Email Summary of Meeting to Discuss Draft ISA RAIs for Alignment Project stage: Request ML23313A1102023-11-17017 November 2023 Triso-X for the Sixth Set of RAIs Including Material Control & Accounting and Fire Safety Project stage: Request ML23320A2052023-11-17017 November 2023 Enclosure 1 - Request for Additional Information for (Programmatic) Structural Review Regarding the TRISO-X License Application Project stage: RAI ML23313A1142023-11-17017 November 2023 Cover Letter - Triso-X License Application Sixth Set of RAIs for Material Control and Accounting, Fire, and Structural Project stage: RAI ML23235A2262023-11-20020 November 2023, 27 November 2023 TRISO-X Fff Environmental RAI Part 2 Project stage: Request ML23343A0022023-12-0909 December 2023 Response to Request for Additional Information Set 5 (Chemical Safety and Radiation Protection) for the TRISO-X License Application Project stage: Response to RAI ML23354A2882023-12-20020 December 2023 TRISO-X, LLC, Response to Request for Additional Information Part 2-1 for the TRISO-X Environmental Report and License Application Project stage: Response to RAI ML23353A1832023-12-27027 December 2023 Summary of Meeting on December 4, 2023, with TRISO-X LLC, to Align on TRISO-X Draft Responses to the Requests for Additional Information for the Chemical Safety Analysis Project stage: Draft RAI ML23353A1822023-12-27027 December 2023 Summary of Meeting Held on December 4, 2023, to Discuss the TRISO-X Draft Responses to the Requests for Additional Information Project stage: Request ML23353A1842023-12-27027 December 2023 Enclosure 1 - Participants List for Summary of Meeting Held December 4, 2023, with TRISO-X, LLC to Align on Draft Responses to Requests for Additional Information for Chemical Safety Analysis Project stage: Draft RAI ML23362A0632024-01-16016 January 2024 12-19-23 Summary of Meeting with Triso-X, LLC, to Align on Triso-X Draft Environmental Safety Request for Additional Information Project stage: Request ML23321A0412024-02-26026 February 2024 Request for Additional Information Set for the Environmental Review Regarding the Triso X License Application Project stage: Request ML23321A0512024-02-26026 February 2024 Enclosure - RAIs Set Seven for the Environmental Safety Review Regarding TRISO-X License Application Project stage: RAI ML23321A0422024-02-26026 February 2024 Cover Letter - RAIs Set Seven for the Environmental Safety Review Regarding the TRISO-X License Application Project stage: RAI ML24065A3132024-03-0404 March 2024 Response to Request for Additional Information Part 2-2 for the TRISO-X Environmental Report and License Application Project stage: Response to RAI ML24057A3622024-03-11011 March 2024 Enclosure - Participants in Meeting Held 2-12-24 with TRISO-X to Discuss the Draft RAIs on Environmental Protection Project stage: Draft RAI ML24057A3612024-03-11011 March 2024 Summary of Meeting on 2-12-24 with TRISO-X to Discuss Draft Requests for Additional Information on Environmental Protection Project stage: Request ML24057A3632024-03-11011 March 2024 Memorandum - Summary of Meeting 2-12-24 with TRISO-X to Discuss Draft RAIs on Environmental Protection Project stage: Draft RAI ML23354A1652024-03-25025 March 2024 Cover Letter - Set Eight Containing a Programmatic Request for Additional Information for the Integrated Safety Analysis Review Regarding the TRISO-X License Application Project stage: RAI ML24087A2352024-03-27027 March 2024 Triso-X, LLC, Response to Request for Additional Information Set 7 (Environmental Safety) for the TRISO-X License Application Project stage: Response to RAI ML24085A2702024-04-0202 April 2024 Request TRISO-X, LLC to Provide Supplemental Information to Resolve Programmatic Requests for Additional Information Regarding the Management Measures and Quality Assurance Portion of the License Application Project stage: RAI ML24095A3412024-04-0404 April 2024 Response to Request for Additional Information Part 3 for the TRISO-X Environmental Report Project stage: Request 2023-12-09
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 December 20, 2024 MEMORANDUM TO:
James Downs, Acting Chief Fuel Facility Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards FROM:
Matthew Bartlett, Sr. Project Manager Fuel Facility Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards
SUBJECT:
SUMMARY
OF NOVEMBER 15, 2024, MEETING WITH TRISO-X, LLC TO DISCUSS SUPPLEMENTAL INFORMATION FOR REQUESTS FOR ADDITIONAL INFORMATION REGARDING CHAPTER TWO OF THE LICENSE APPLICATION (ENTERPRISE PROJECT IDENTIFIER L-2022-NEW-0005)
The U.S. Nuclear Regulatory Commission (NRC) staff held a meeting with a representative from TRISO-X, LLC (TRISO-X) on November 15, 2024. The purpose of the meeting was to discuss supplemental information to resolve requests for additional information (RAIs) regarding chapter-2 of the license application (LA). The RAIs were issued on July 27, 2023, (Agencywide Documents Access and Management System [ADAMS] Accession No. ML23198A257) and the responses were received August 25, 2023 (ML23237B484).
The NRC staff informed TRISO-X that the responses for RAIs 1, 3, 5, 7, and 8 required supplemental information via letter dated May 8, 2024 (ML24089A200). In preparation for the meeting on November 15, 2024, the NRC staff provided several slides to inform the discussions on the supplemental response needed for each RAI.
Discussion on RAI 1, Management Hierarchy The NRC staff identified that a range of terms are used for manager positions throughout chapter 2 of the LA. The organization of the major management positions are listed as discipline and function leads in the LA on figure 2-1, Functional Organization Chart. During the discussions, TRISO-X clarified that the positions listed in the first line below the Plant Manager are the four major disciplines of the facility, each overseen by an assigned manager. All the boxes below these four disciplines are functional areas of the facility, which will also be led by a functional manager. TRISO-X indicated they would consider how to distinguish between the disciplines and the functions on the chart.
CONTACT: Matthew Bartlett, NMSS/DFM 301-415-7154 Signed by Bartlett, Matthew on 12/20/24
J. Downs 2
They also agreed to refine the description of the various management positions throughout chapter 2 to make them more consistent and ensure they align with figure 2.1. The NRC staff also requested that TRISO-X clarify whether the disciplines and functions will have an assigned manager to oversee each organizational group. TRISO-X pointed out that multiple functions may be led by the same manager. The NRC staff agreed this was acceptable, provided the responsibilities and qualifications for each position is met.
Discussion on RAI 3 and 5, Role of Regulatory Affairs on the Screening Committee The NRC staff asked TRISO-X to clarify the manager positions that would be represented on the safety committee. TRISO-X stated that five individuals will serve on the safety committee as represented by the darkened boxes in figure 2.1. This includes the two discipline managers from manufacturing and engineering; the regulatory affairs manager or designee; and the manager of the Safety and Regulatory function and the Safeguards function. The NRC staff asked TRISO-X to clarify in the text that these five individuals would serve on the safety committee. The NRC staff also pointed out that the training requirements for the safety committee need to be clarified.
TRISO-X indicated the safety committee would have training on their responsibilities in the committee.
Discussion on RAI-7 Experience for the Manufacturing Function, etc.
The NRC staff pointed out that the qualification requirements for the various discipline managers and function managers needs to be clarified. As currently written, the qualification requirements appear to apply to all members of the discipline or functions. TRISO-X agreed the language would be updated. They intend that all members of a discipline or function will be appropriately trained for their specific roles, but the qualifications described in chapter 2 of the LA only apply to the individual managers of the disciplines and functions. TRISO-X also pointed out that some specific technical positions have training requirements. The NRC staff stated that business experience should not be used in place of nuclear experience, without some additional support from individuals with nuclear experience. The NRC staff indicated that those criteria need to be described in the LA. The TRISO-X staff agreed and clarified that business experience would only be used as a substitute for other experience when appropriate (e.g.,
management experience).
Discussion on RAI-8 Transition to Operations The NRC staff pointed out that TRISO-X needs to demonstrate that the construction of safety related systems will have appropriate oversight from the regulatory affairs discipline. TRISO-X agreed and pointed out that several revisions to the LA were submitted in response to the RAI for the management measures and quality assurance program.
At the conclusion of the meeting, the NRC and TRISO-X staff agreed that the supplemental information to the RAIs would be incorporated into the revised LA to be submitted in December 2024. The NRC staff considers that the supplements agreed during the call should be sufficient to resolve these RAI, provided the issues are incorporated in the revised LA, as agreed.
J. Downs 3
The meeting participants include the following individuals:
NRC Staff TRISO-X Staff Matt Bartlett, Senior Licensing Project Manager Jennifer Wheeler, Vice President of Regulatory Affairs James Downs, Acting Branch Chief, Fuel Facility Licensing Branch Docket No.: 07007027
Enclosures:
- 1. NRC Slides
ML24352A091(pkg), ML24352A092(memo), ML24352A093(encl)
OFFICE NMSS/DFM/FFLB NMSS/DFM/FFLB NMSS/DFM/FFLB NMSS/DFM/FFLB NAME MBartlett JGoodridge JDowns MBartlett DATE 12/19/2024 12/20/2024 12/20/2024 12/20/2024