From:
Nielsen, Adam To:
Andrews, Sherry E Cc:
Kellner, Bob; Diaz, Jose; Bell, Jack
Subject:
RP inspection document request - Catawba 2022-03 Date:
Thursday, July 28, 2022 9:59:00 AM Attachments:
CAT_22-03_Doc_Request.pdf Please see the attached document request. Note that some of the items may be outside RPs purview, so some coordination with other groups might be required (e.g. rad monitor calibration records, ventilation testing records, etc.).
We would like to have the documents available by September 2, 2022. However, if you run into difficulty and need more time for certain items, just let us know and we can work with you.
Also, just a reminder that we would prefer the documents to not be placed in.zip files anymore.
Please call me with any questions.
- Thanks, Adam Nielsen Senior Health Physicist US NRC Region II (404) 997-4660 ML22213A047
Catawba Nuclear Station Radiation Safety Baseline Inspection Initial Information Request Inspection Report: 2022003 During the weeks of September 12 - 16 and September 26 - 30, 2022, the U.S. Nuclear Regulatory Commission (NRC) will perform a baseline Radiation Safety Inspection at Catawba Nuclear Station (NRC Inspection Procedures 71124.01, 71124.03, 71124.04, 71124.05 &
71151).
To minimize the impact to your onsite resources during the inspection and ensure the inspectors have the necessary information to complete the inspection while on site, we have enclosed a request for documents needed for this activity. The NRC requests that these documents be provided to the inspectors no later than September 2, 2022.
If there are any questions about this inspection or the material requested, please contact the lead inspector, Adam Nielsen, at 404-997-4660, or the Engineering Branch 3 Chief, Binoy Desai at 404-997-4519.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public inspections, exemptions, requests for withholding: a copy of this document will be available electronically for public inspection in the NRC Public Document Room, or from the Publicly Available Records component of NRC's Agencywide Documents Access and Management System (ADAMS); accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
PAPERWORK REDUCTION ACT STATEMENT This document does not contain new or amended information collection requirements subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection requirements were approved by the Office of Management and Budget under control numbers 3150-0008, 3150-0011, 3150-0014, 3150-0044, and 3150-0135.
PUBLIC PROTECTION NOTIFICATION The NRC may not conduct or sponsor, and a person is not required to respond to, a request for information or an information collection requirement, unless the requesting document displays a currently valid Office of Management and Budget control number.
2 Document Request List Licensee:
Catawba Nuclear Station Docket Number:
05000413 and 414 Inspection Dates:
September 12-16 and 26-30, 2022 Documents Due to Region II by:
September 2, 2022 Inspection Procedures (IPs):
71124.01 Radiological Hazard Assessment and Exposure Controls 71124.03 In-Plant Airborne Radioactivity Control and Mitigation 71124.04 Occupational Dose Assessment 71124.05 Radiation Monitoring Instrumentation 71151 Performance Indicator Verification (Public and Occupational)
Note: Please provide the current version of these documents in an electronic format if possible (The preferred file format is MSWord, or searchable.pdf files). To the extent possible, please organize the information in directories as requested below. Please do not submit the files as bundled.zip files unless specifically requested to do so. Please redact all PII in any records submitted. If you have any questions, please contact the lead inspector.
Inspector Contact Information:
adam.nielsen@nrc.gov 404-997-4660 General and Miscellaneous Information
- 1. List of primary site contact(s) for each inspection area including name(s) and telephone numbers.
- 2. Corrective Action Program procedures.
- 3. Plant Management and Radiation Protection organizational charts w/ contact numbers.
- 4. High level schedule for the upcoming refueling outage, focusing on activities planned for the weeks of inspection.
71124.01 - Radiological Hazard Assessment and Exposure Controls
- 1. List of active RWPs, including outage RWPs, with their administrative limits, electronic dosimeter dose rate limit, and dose limit.
- 2. Procedures related to RP controls (e.g. Posting, labeling, surveys, RWPs, contamination control, HRA/LHRA/VHRA control, key control, control of divers, special controls during fuel offload, hot spots, etc.).
- 3. Procedures related to release of personnel and materials (e.g. release surveys, decontamination, guidance for alarm follow up, etc.).
- 4. List of all non-fuel items stored in the spent fuel pool(s).
- 5. ALARA work plans for the top 3 highest dose jobs for the upcoming refueling outage
- 6. Outage ALARA report from the previous refueling outage
- 7. Most recent self-assessment or audit covering RP controls
- 8. List of CRs related to RP controls/ALARA (e.g. radworker error, RP technician error, ALARA issues, posting issues, HRA/LHRA/VHRA issues, survey problems, etc.) since
3 October 23, 2021. This should be a list of corrective action documents containing an AR number and brief description, not full CRs.
71124.03 - In-Plant Airborne Radioactivity Control and Mitigation
- 1. Procedures related to airborne monitoring and control (e.g. use of purge systems, use of portable HEPA/charcoal units, temporary ventilation enclosures, use of CAMs, air sampling guidance, Alpha air sampling, etc.), as applicable
- 2. Procedures related to the use of respiratory protection devices, (e.g. SCBA, TEDE-ALARA guidance, PAPRs, storage, maintenance, training, QA, fit-testing, etc.)
- 3. The last 2 grade D air testing certificates for each supplied air system and SCBA filling station
- 4. SCBA qualification records a)
List of all licensed operators qualified to use SCBA b)
List of all Maintenance personnel qualified to use SCBA
- 5. The last 2 surveillances performed on SCBA stored for emergency use
- 6. The last 2 in-place filter testing surveillances of the HEPA/charcoal banks for the Main Control Room emergency air filtration system (last two for all trains).
- 7. Most recent audit or self-assessment covering airborne controls and respiratory protection
- 8. List of CRs related to airborne monitoring and respiratory protection since September 19, 2020. This should be a list of corrective action documents containing an AR number and brief description, not full CRs.
71124.04: Occupational Dose Assessment (Reminder: Please redact all PII in any records submitted)
- 1. Procedures related to occupational dose assessment (e.g. dosimetry issuance and use, unusual dosimetry occurrences, multi-badging/extremity dosimetry/badge relocation, Effective Dose Equivalent, personnel contamination events, in-vivo and in-vitro internal dose assessment, skin dose assessment, QC for whole body counter, use of passive monitoring if applicable, declared pregnant workers)
- 2. Current NVLAP accreditation certificate for lab used to process dosimetry
- 3. List of all dosimetry events that met the following criteria since September 19, 2020:
- a. CEDE > 10 mrem
- b. SDE> 500 mrem
- c. Neutron dose > 50 mrem
- 4. List of all management over-rides of administrative annual dose limits since September 19, 2020
- 5. List of all personnel contamination events identified since September 19, 2020.
- 6. Most recent alpha source term plant characterization
- 8. Copies of current WBC libraries (e.g. routine, medical, investigative, etc.)
- 9. The most recent DLR/SRD correlation analysis.
- 10. Most recent audit or self-assessment of the dosimetry program
- 11. List of CRs generated since September 19, 2020 for internal or external dosimetry issues/events. This should be a list of corrective action documents containing an AR number and brief description, not full CRs.
4 71124.05 - Radiation Monitoring Instrumentation
- 1. Procedures for:
a) calibration and source checks of portable radiation detection instruments b) calibration and source checks of small article monitor, personnel contamination monitor, portal monitor, whole body counting equipment, and continuous air monitors c)
QA program for count room instruments
- 2. The last 2 calibration records for each of the following instruments:
a) Waste Liquid Discharge (EMF-49) b) Unit 1 Unit Vent Gas (1-EMF-36) c) Unit 1 Unit Vent Gas High Range (1-EMF-54) d) Unit 1 Containment High Range Area Radiation Monitor (1-EMF-53B) e) Unit 2 Containment High Range Area Radiation Monitor (2-EMF-53B)
- 3. Radioactive source paperwork for the sources used to calibrate the instruments in item 2 above. This paperwork should include NIST/NBS certificates, as applicable, and traceability to the primary (factory) calibration
- 4. The last two in-place filter testing surveillances for the HEPA/charcoal banks of the Unit 1 containment purge discharge pathway
- 5. The last 2 calibration records for each of the following RCA exit point instruments:
- a. All portal monitors located at RCA exit
- b. All small article monitors located at RCA exit
- c. All personnel contamination monitors (ARGOS or equivalent) at RCA exit
- 6. Most recent calibration record of the Whole Body Counter used by Dosimetry
- 7. Most recent calibration record for all gamma spectroscopy detectors in the count room
- 8. Most recent calibration record for all liquid scintillation detectors in the count room
- 9. Most recent test record of the instrument calibrator (Shepherd validation testing/dose rate curves)
- 10. Interlaboratory comparison results for the onsite count room, going back two years.
- 11. Most recent audit or self-assessment covering RP and count room instruments (portables, RCA exit point, WBC, count room).
- 12. Most recent Radiation Monitoring System health report, if applicable.
- 13. List of CRs generated since September 19, 2020 related to portable instruments, area monitors, effluent monitors, CAMs, RCA release point monitors, WBCs, and count room instruments. This should be a list of corrective action documents containing an AR number and brief description, not full CRs.
71151 - Performance Indicator (PI) Verification
- 1. Procedures for gathering and reporting NRC PI data
- 2. List of electronic dosimeter alarms since October 23, 2021 (dose and dose rate)
- 3. List of CRs related to ODCM/SLC/effluent monitoring issues since May 29, 2021. This should be a list of corrective action documents containing an AR number and brief description, not full CRs.
- 4. 2021 Annual Effluent Report
- 5. 2022 year-to-date effluent dose summary