ML22174A080
| ML22174A080 | |
| Person / Time | |
|---|---|
| Site: | Catawba |
| Issue date: | 06/01/2022 |
| From: | Duke Energy |
| To: | Auten R Office of Nuclear Reactor Regulation |
| References | |
| TR-NUC-CN-014344 | |
| Download: ML22174A080 (13) | |
Text
Auten, Rhoda J From:
FusionP8NoReplyNProd@duke-energy.com Wednesday, June 1, 2022 8:33 AM Sent:
To:
Auten, Rhoda J
Subject:
[Fusion P8] TR-NUC-CN-014344 - Transmittal External Distribution Transmittal External Distribution Notification TR-NUC-CN-014344 - SLC Manual Revision to LOES and SLC 16.7-5 You're receiving this message because you're the Responsible Internal User for (CNS) US NUC REG WASHINGTON DC external recipient with the following distribution:
LICN - CN - CNS-SLC-16.7 005 - ISSUED (Turbine Overspeed Protection)
LICN - CN - CNS-SLC-LOES - 107 - ISSUED (List of Effective Sections)
LICN - CN - SLC Letter to Manual Holders - 107 - ISSUED (SELECTED LICENSE COMMITMENTS MANUAL HOLDERS LETTER (REV 107))
The contact details for (CNS) US NUC REG WASHINGTON DC are as follows:
Email: Kenny.Nguyen@NRC.Gov
==
Description:==
DOCUMENT CONTROL DESK 11555 ROCKVILLE PIKE ROCKVILLE, MD 20852 Please note the following:
You're required to deliver listed documents to the external recipient via the agreed media. You can use the links above to access individual documents or click here to open the Transmittal in Fusion where you can export all documents in a batch.
All the documents are distributed to you for notification purposes only. You're not required to complete any actions in Fusion PS in regards to the distribution listed above.
Record(s) listed above may have viewer restrictions causing you to be unable to view the data information or the actual record. If you have questions related to these types of records and their limited access contact your management.
All Distribution Actions requiring Review and Acknowledgement or Printing must be completed within 14 days of receipt or an AR will be generated against recipient of the Distribution Action.
For instructions on closing out your transmittal actions please refer to QRG-ALL-0005, Receipt of Transmittal Via Email Distribution. This can be located in Fusion under Controlled Documents > Procedures Category > Functional Area Documents.
This message was automatically generated by Fusion P8. Please do not reply to it.
1
Remove and Insert Replace the following page(s) of Catawba Nuclear Station Selected Licensee Commitments (SLC) Manual with the attached revised page(s). The revised page(s) are identified by Section number and contains marginal lines indicating the areas of change.
REMOVE THESE PAGES INSERT THESE PAGES LIST OF EFFECTIVE SECTIONS Pages 1-5 Revision 106 16.7-5, Pages 1-6 Revision 6 TAB 16.7 Pages 1-5 Revision 107 16.7-5, Pages 1-6 Revision 7 If you have any questions concerning the contents of this Catawba Nuclear Station Selected Licensee Commitments (SLC) Manual update, please contact Nicole Edwards (704)382-6669.
16.7 INSTRUMENTATION
- 16. 7-5 Turbine Overspeed Protection Turbine Overspeed Protection 16.7-5 COMMITMENT Turbine Overspeed Protection System shall be FUNCTIONAL.
APPLICABILITY:
MODES 1, 2, and 3.
REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
One stop valve or one A.1 Restore non-functional 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> control valve per high valve(s) to FUNCTIONAL pressure turbine steam status.
line non-functional.
OR A.2 Close at least one valve in 78 hours9.027778e-4 days <br />0.0217 hours <br />1.289683e-4 weeks <br />2.9679e-5 months <br /> affected steam line(s).
OR A.3 Isolate the turbine from the 78 hours9.027778e-4 days <br />0.0217 hours <br />1.289683e-4 weeks <br />2.9679e-5 months <br /> steam supply.
B.
One intermediate stop B.1 Restore non-functional 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> valve or one intercept valve(s) to FUNCTIONAL valve per low pressure status.
turbine steam line non-functional.
OR B.2 Close at least one valve in 78 hours9.027778e-4 days <br />0.0217 hours <br />1.289683e-4 weeks <br />2.9679e-5 months <br /> affected steam line(s).
OR B.3 Isolate the turbine from the 78 hours9.027778e-4 days <br />0.0217 hours <br />1.289683e-4 weeks <br />2.9679e-5 months <br /> steam supply.
( continued)
Catawba Units 1 and 2
- 16. 7-5-1 Revision 7
Turbine Overspeed Protection 16.7-5 REMEDIAL ACTIONS (continued)
CONDITION C.
Electrical or Mechanical Overspeed Protection Non-Functional D.
Turb ine Overspeed Prot ection System non-func tional for reasons othe r than Condition A, B or C.
TESTING REQUIREMENTS REQUIRED ACTION C.1 Determine missile probability P1 value and perform required actions as determined by the probability criteria table located in the bases.
OR C.2 Isolate the turbine from the steam supply.
D. 1 Isolate the turbine from the steam supply.
TEST TR 16.7-5-1
NOTES-------------
- 1.
- 2.
This TR shall be performed in MODE 1 or in MODE 2 with the turbine operating.
Not required to be performed until 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after each valve is opened.
- COMPLETION TIME 6 days 150 hours0.00174 days <br />0.0417 hours <br />2.480159e-4 weeks <br />5.7075e-5 months <br /> 6 hours FREQUENCY Cycle while performing a direct observation of the four In accordance with high pressure turbine stop valves, six low pressure SLC 16.7-5 Bases turbine intermediate stop valves, six low pressure turbine intercept valves, and four high pressure turbine control valves, through one complete cycle from the running position.
TR 16.7-5-2 Perform CHANNEL CALIBRATION.
18 months (continued)
Catawba Units 1 and 2 16.7-5-2 Revision 7 I
I
TEST Turbine Overspeed Protection 16.7-5 FREQUENCY TR 16. 7-5-3 Disassemble at least one each of the four high pressure 54 months turbine stop valves, six low pressure turbine intermediate stop valves, six low pressure turbine intercept valves, and four high pressure turbine control valves, and perform a visual and surface inspection of valve seats, disks, and stems, and verify no unacceptable flaws or corrosion.
TR 16.7-5-4 Perform mechanical trip testing.
In accordance with SLC 16.7-5 Bases TR 16.7-5-5 Perform electrical trip testing.
In accordance with SLC 16.7-5 Bases BASES This COMMITMENT is provided to ensure that the Turbine Overspeed Protection instrumentation and the turbine speed control valves are FUNCTIONAL and will protect the turbine from excessive overspeed.
Protection from turbine excessive overspeed is required since excessive overspeed of the turbine could generate potentially damaging missiles which could impact and damage safety related components, equipment, or structures.
The term "Isolate the turbine from the steam supply" used in Required Actions A.3, B.3, C.2 and D.1 can be met in several ways. These include:
Maintaining the turbine in a tripped condition; or Hydraulically gagging all four main stop valves closed; or Hydraulically gagging all four main control valves closed; or Closing the main steam isolation valves. and main steam isolation valve bypass valves.
Calculation CNC 1200.00-00-0006 provides qualitative and quantitative assessment for interval extension on Turbine Valve Movement Testing (TVMT). The calculation concludes that it is allowable to have a maximum 18-month TVMT interval for HP Stop Valves, HP Control Valves and LP Combined Intermediate Valves, based on main turbine missile probabilities. It is desired to incrementally extend the current test frequency from 4 months to 18 months based on two successful tests at each extended test interval no greater than half the previous test interval (e.g. the 4-month frequency would be extended to 6-months; the 6-month interval would be extended to 9 months and the 9 month frequency to 12 months, the 12 month frequency to 15 months and finally the 15 month interval to 18 months). The other recommendation is that CNS trend EHC fluid quality measurements to ensure fluid quality remains within acceptable limits. CNS currently takes Monthly samples and verifies EHC fluid is within OEM recommended limits (PMRQs 02031192-02 and Catawba Units 1 and 2 16.7-5-3 Revision 7
BASES (continued)
Turbine Overspeed Protection 16.7-5 02031193-02). Both CNS units start at a 4M frequency for all Turbine Valve Movement Testing, within OEM acceptable limits. Extending TVMT frequencies through calculation CNC 1200.00-00-0006, the TVMT PM strategy is to extend valve testing out in 3 month increments after a minimum of 2 iterations. These TVMT intervals may be increased until the frequency reaches a maximum of 18 months between TVMT tests.
The testing frequencies will be extended in accordance with the strategy given below until the maximum frequency is reached.
4M to 6M - Allow for testing at this interval and collect data (a minimum of 2 Turbine Valve Movement Tests at this frequency) 6M to 9M - Allow for testing at this interval and collect data (a minimum of 2 Turbine Valve Movement Tests at this frequency) 9M to 12M - Allow for testing at this interval and collect data ( a minimum of 2 Turbine Valve Movement Tests at this frequency) 12M to 15M - Allow for testing at this interval and collect data (a minimum of 2 Turbine Valve Movement Tests at this frequency) 15M to 18M - Allow for testing at this interval and collect data (a minimum of 2 Turbine Valve Movement Tests at this frequency)
PMRQs that document current frequency and drive execution:
02031173 PT/1/A/4250/02B MAIN TURB VALVE MOV'T TEST 02031173 PT/1/A/4250/02C TURBINE CONTROL VALVE MOV'T TEST 02031172 PT/2/A/4250/02B MAIN TURB VALVE MOVEMENT TEST 02031172 PT/2/A/4250/02C TURBINE CONTROL VALVE MOVEMENT TEST Calculation CNC 1200.00-00-0006 also performed analysis on extending out mechanical and electrical (backup) trip testing, based on turbine missile probabilities. The calculation concludes that a maximum frequency of 2-Months on mechanical trip testing and 1-Month for electrical trip testing is allowable. The maximum extensions for trip testing are based on requirements that CNS extends the interval out in steps and no more than double of the previous test interval. The other recommendation is that CNS trend EHC fluid quality measurements to ensure fluid quality remains within acceptable limits. Extending trip test frequencies through calculation CNC 1200.00-00-0006, the Turbine Trip test PM strategy is to extend trip testing out no more than double of the previous test interval after a minimum of 2 iterations. The testing frequencies will be extended in accordance with the strategy given below until the maximum frequency is reached.
1W to 2W -Allow for testing at this interval and collect data (a minimum of 2 Turbine Trip Tests at this frequency) 2W to 1 M - Allow for testing at this interval and collect data (a minimum of 2 Turbine Trip Tests at this frequency) 1 M to 2M - This would only be optional for the mechanical trip testing upon a minimum of 2 successful mechanical trip tests.
Catawba Units 1 and 2 16.7-5-4 Revision 7
Turbine Overspeed Protection 16.7-5 BASES (continued)
Case A
B C
PMRQs that document current frequency and drive execution:
02031173 PT/1/B/4250/02A MAIN TURBINE WEEKLY TRIP TEST 02031172 PT/2/B/4250/02A MAIN TURBINE WEEKLY TRIP TEST NU REG 0800 3.5.1.3 documents the NRC's review with regard to turbine missile generation and concluded that the probability of unacceptable damage to safety related systems and components resulting from missile damage is acceptably low (i.e less than 10-7 per year) provided the total turbine missile generation probability (P1) is maintained below 104 per reactor year. The application of NUREG 0800 Section 3.5.1.3 Table 3.5.1.3-1 for favorably oriented turbines provides additional NRC approved P1 values and recommended licensee actions if the turbine is online.
Calculation CNC 1200.00-00-0006 contains missile generation probability (P1) values for different scenarios that can be used to determine the resulting missile probability (P1) for a given condition to be used in conjunction with the Probability Criteria Table to determine the required action. Any change in system or component reliability will require use of the same methodology used in CNC-1200.00-0006 to determine any new P1 value to ensure missile probabilities do not exceed NUREG 0800 Section 3.5.1.3 Table 3.5.1.3-1 criteria.
The turbine trip test requirement in TR 16.7-5-4 and TR 16.7-5-5 can be temporarily extended if the execution of the test creates unacceptable risk during execution. The effect of the probability (P1) must be evaluated prior to the temporary frequency extension to ensure the P1 value remains below the high value for Probability Criteria in Case B.
Both mechanical and electrical trips non-functional requires entry into Condition D.
Probability Criteria Annual Probability Required Actions P1 < 104 This condition represents the general, minimum reliability requirement for loading the turbine and bringing the system online 104 < P1 < 10-3 If this condition is reached during operation, the turbine may be kept in service until the next scheduled outage, at which time the licensee must take action to reduce P1 to meet the Case A criterion before returning the turbine to service 10-3 < P1 < 10-2 If this condition is reached during operation, the turbine must be isolated from the steam supply within 60 days, at which time the licensee must take action to reduce P1 to meet the Case A criterion before returning the turbine to service.
Catawba Units 1 and 2 16.7-5-5 Revision 7
D 10-2 < P1 REFERENCES
- 1.
Turbine Overspeed Protection 16.7-5 If this condition is reached during operation, the turbine must be isolated from the steam supply within 6 days, at which time the licensee must take action to reduce P1 to meet the Case A criterion before returninq the turbine to service.
CNC 1200.00-00-0006 - Catawba Turbine Overspeed Protection System Maintenance and Test Interval Extension Assessment.
- 2.
CNM 1200.00-0212.001 -Turbine Instruction Manual.
- 3.
NUREG 0800 3.5.1.3 Turbine Missiles - Revision 3 - March 2007.
Catawba Units 1 and 2 16.7-5-6 Revision 7
r-LIST OF EFFECTIVE SECTIONS SECTION REVISION NUMBER REVISION DATE TABLE OF CONTENTS 15 05/10/16 16.1 1
08/27/08 16.2 2
08/21/09 16.3 1
08/21/09 16.5-1 7
03/30/21 16.5-2 Deleted 16.5-3 2
09/19/19 16.5-4 1
01/27/22 16.5-5 1
01/28/10 16.5-6 2
02/16/22 16.5-7 2
02/06/15 16.5-8 Deleted 16.5-9 Deleted 03/02/21 16.5-10 Deleted 16.6-1 0
10/09/02 16.6-2 Deleted 16.6-3 2
01/27/22 16.6-4 2
11/21/19 16.6-5 3
07/07/20 16.7-1 1
08/21/09 16.7-2 4*
02/03/11 16.7-3 5
11/21/19 16.7-4 2
08/21/09 16.7-5 7
06/01/22 Catawba Units 1 and 2 Page 1 Revision 107
LIST OF EFFECTIVE SECTIONS SECTION REVISION NUMBER REVISION DATE 16.7-6 3
06/10/16 16.7-7 1
08/21/09 16.7-8 2
08/21/09 16.7-9 13 09/14/21 16.7-10 10 01/27/22 16.7-11 1
08/21/09 16.7-12 1
08/21/09 16.7-13 3
06/10/16 16.7-14 1
08/21/09 16.7-15 2
01/27/22 16.7-16 0
06/08/09 16.7-17 0
02/10/15 16.7-18 0
05/10/16 16.8-1 8
01/27/22 16.8-2 3
12/18/19 16.8-3 1
10/24/06 16.8-4 2
11/05/07 16.8-5 3
08/21/09 16.9-1 10 01/29/19 16.9-2 6
08/03/17 16.9-3 5
07/03/18 16.9-4 5
09/11/17 16.9-5 11 10/08/19 16.9-6 12 07/03/18 Catawba Units 1 and 2 Page 2 Revision 107
LIST OF EFFECTIVE SECTIONS SECTION REVISION NUMBER REVISION DATE 16.9-7 4
08/21/09 16.9-8 5
08/21/09 16.9-9 3
08/21/09 16.9-10 5
08/21/09 16.9-11 3
08/21/09 16.9-12 3
02/10/15 16.9-13 4
09/27/16 16.9-14 1
09/25/06 16.9-15 2
08/21/09 16.9-16 2
08/21/09 16.9-17 0
10/09/02 16.9-18 Deleted 16.9-19 3
02/20/12 16.9-20 0
10/09/02 16.9-21 1
10/13/16 16.9-22 1
08/21/09 16.9-23 5
08/03/17 16.9-24 2
10/24/06 16.9-25 2
08/21/09 16.9-26 1
11/15/18 16.10-1 1
08/21/09 16.10-2 1
10/24/06 16.10-3 1
08/21/09 16.10-4 0
08/04/20 Catawba Units 1 and 2 Page3 Revision 107
LIST OF EFFECTIVE SECTIONS SECTION REVISION NUMBER REVISION DATE 16.10-5 1
03/16/21 16.11-1 1
07/27/13 16.11-2 8
05/03/22 16.11-3 0
10/09/02 16.11-4 1
08/21/09 16.11-5 0
10/09/02 16.11-6 3
08/03/15 16.11-7 14 05/03/22 16.11-8 0
10/09/02 16.11-9 0
10/09/02 16.11-10 1
08/21/09 16.11-11 1
03/20/03 16.11-12 0
10/09/02 16.11-13 1
07/27/13 16.11-14 0
10/09/02 16.11-15 0
10/09/02 16.11-16 1
10/24/11 16.11-17 0
10/09/02 16.11-18 1
08/21/09 16.11-19 0
10/09/02 16.11-20 3
11/21/19 16.11-21 0
10/09/02 16.12-1 0
10/09/02 16.13-1 1
08/03/17 16.13-2 Deleted Catawba Units 1 and 2 Page4 Revision 107
SECTION 16.13-3 16.13-4 Catawba Units 1 and 2 LIST OF EFFECTIVE SECTIONS REVISION NUMBER Deleted 4
Page 5 REVISION DATE 10/04/21 Revision 107