Requests Approval to Allow Installation of machine-welded SG Tube Plugs,Iaw Provisions of Paragraph IWB-4230 of Section XI of ASME Boiler & Pressure Vessel Code,1989 Edition
ML20216C969
Person / Time
Site: Davis Besse 
Issue date: 04/06/1998
From: Jeffery Wood
CENTERIOR ENERGY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
2532, NUDOCS 9804150123
Download: ML20216C969 (2)


Text

I l

r y-l i

9"- -

Davis-Besse Nuclear Power Statron E EE Y 550 t North State Rou:e 2

.. m Oak Harborf'Tio 43469760

?

John K. Wood 41% 249-2 Vice President. Nuclear Fax: 419-32141337 Docket Number 50-346 4

i License Number NPF-3 Serial Number 2532 April 6, 1998 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001

Subject:

Request for Approval to Install Machine-Welded Steam Generator Tube Plugs j

In Accordance With ASME Section XI,1989 Edition l

Ladies and Gentlemen:

The purpose of this letter is to request approval to allow installation ofinachine-welded I

steam generator tube plugs at the Davis-Besse Nuclear Power Station (DBNPS), Unit Number 1, in accordance with the provisions of Paragraph IWB-4230," Tube or Tubesheet Hole Plugging by Fusion Welding," of Section XI," Rules for Inspection of j

Nuclear Power Plant Components," of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,1989 Edition.

The DDNPS is currently committed to the 1986 Edition of ASME Section XI, with no I

addenda. Paragraph IWB-4230 of the 1989 Edition of ASME Section XI, which was first incorporated into ASME Section XI as IWB-4430 in the August 1986 Addenda, provides for machine-welding of plugs to the tube or tubesheet.

Although the DBNPS is committed to an earlier version of the Code which does not include provisions for installation of machine-welded tube plugs, Code Case N-389,

" Alternative Rules for Repairs, Replacements, or Modifications,Section XI, Division 1," dated July 25,1983, applies in this situation. This Code Case states, in part:

... Editions and Addenda of Section XI, Division 1, subsequent to those specified in the Owner's Inservice Inspection Program may be used for repair, replacement, or l

modification, provided the Edition and Adenda have been accepted by the 3

enforcement and regulatory authorities having jurisdiction at the plant site.

D

()J.'

&x

\\

9804150123 900406 3

PDR ADOCK 05000346 p

PDR

s

. Docket Number 50-346 License Number NPF-3 Serial Number 2532 Page 2-The 1989 Edition of ASME Section XI was endorsed by the NRC in 10 CFR 50.55a,

" Codes and Standards," Paragraph (b)(2). Code Case N-389 was approved by the NRC in Revision 1I (October,1994) of Regulatory Guide 1.147," Inservice Inspection Code Case Acceptability, ASME Section XI Division 1," with the following provision:

The applicant should submit for approval the appropriate edition and addenda of the Code that is to be used for the repair, replacement, or modification before the start of the work.

Subject to NRC approval, the DBNPS intends to install machine-welded steam 0

generator plugs, as necessary, during the upcoming Eleventh Refueling Outage (11RFO), which is scheduled to commence on April 11,1998. The plugs are designed and fabricated to the requirements of ASME Section III," Rules for Construction of j

Nuclear Power Plant Components, Division 1," Subsection NB," Class 1 Components,"

1989 Edition, no addenda. The installation procedures are qualified in accordance with ASME Section XI,1989 Edition, Paragraph IWB-4230. In the event welded plugs are necessary for steam generator repairs during i IRFO, use of machine-welded plugs versus manually welded plugs is expected to save considerable worker dose.

Toledo Edison requests that this request be approved by April 22,1998.

Should you have any questions or require additional information, please contact Mr. James L. Freels, Manager - Regulatory Affairs, at (419) 321-8466.

Very truly yours,

.f.

F0R MKUlaj cc: