i W

~ ~ $ U$$

E EE sso m

Ook Harbor, ohio 43449-9760

\\

auy a. campseu 41 m t.asee VMe Pmident-Nuclear Fax:419-321-8337 Docket Number 50-346

)

License Number NPF-3 Serial Number 2500 June 10, 1999 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001

Subject:

License Amendment Application to Revise Technical Specification (TS) 3/4.6.4.4 - Hydrogen Purge System, TS 3/4.6.5.1 - Shield Building Emergency Ventilation System, TS 3/4.7.6.1 - Control Room Emergency Ventilation System, and TS 6.0 - Administrative Controls regarding a Ventilation Filter Testing Program (LAR 96-0013)

Ladies and Gentlemen:

/4 Enclosed is an application for an amendment to the Davis-Besse Nuclear Power Station (DBNPS), Unit Number 1 Operating License NPF-3, Appendix A, Technical System, TS 3/4.6.5.1 - Shield Building Emergency Ventilation Specifications (TS). The proposed changes involve TS 3/4.6.4.4 - Hydrogen Purge

- Control Room Emergency Ventilation System and TS 6.0 - Administrative l

Controls. The proposed changes also involve the Bases to TS 3/4.6.4.4, TS 3/4.6.5.1 l

and TS 3/4.7.6.1.

This application proposes adoption of a Ventilation Filter Testing Program (VFTP) in TS Section 6.0 - Administrative Controls and removal of the specific ventilation filter testing requirements from the DBNPS Surveillance Requirements (SR) of TS 3/4.6.4.4, TS 3/4.6.5.1, and TS 3/4.7.6.1. The filter testing requirements of these TS will be replaced with a reference to the Ventilation Filter Testing Program requirements being added in TS Section 6.8.4.f-Ventilation Filter Testing Program. This line item TS improvement is based upon the NRC guidance of

- NUREG-1430 Revision 1, Standard Technical Specifications - Babcock and Wilcox Plants.

. S 9906150131 990610

~

PDR ADOCK 05000346 P

peg

4 Docket Number 50-346 License Number NPF-3 Serial Number 2500 Page 2 i

The FirstEnergy Nuclear Operating Company requests that the NRC issue this amendment by December 10,1999.

Should you have any questions or require additional information, please contact Mr. James L. Freels, Manager - Regulatory Affairs, at (419) 321-8466.

i Very truly yours, WA y

FWK/laj Enclosure I

cc:. S. J. Campbell, DB-1 NRC Senior Resident Inspector (Acting)

J. E. Dyer, Regional Administrator, NRC Region III W. O. Long, DB-1 NRC/NRR Senior Project Manager J. R. Williams, Executive Director, Ohio Emergency Management Agency, State of Ohio (NRC Liaison)

Utility Radiological Safety Board