ML20154Q038
| ML20154Q038 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 03/14/1986 |
| From: | Shafer W NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | |
| Shared Package | |
| ML20154Q036 | List: |
| References | |
| 50-255-86-02, 50-255-86-2, NUDOCS 8603210013 | |
| Download: ML20154Q038 (1) | |
Text
. - _ _ _ _ _ _ _ _ _
NOTICE OF VIOLATION Consumers Power Company Docket No. 50-255 As a result of the inspection conducted on January 7-10, 23-25, 29, and 30, and February 28, 1986, and in accordance with the General Policy and Procedures for NRC Enforcement Actions, (10 CFR Part 2, Appendix C), the following violation was identified:
Technical Specification 6.12.1 states that any individual or group of individuals permitted to enter a high radiation area shall be provided with or accompanied by one or more of the following:
a radiation monitoring device which continuously indicates the radiation dose rate in the area; a radiation monitoring device which continuously integrates the radiation dose rate in the area and alarms when a preset integrated dose is received; or an individual qualified in radiation protection procedures who is equipped with a radiation dose rate monitoring device.
This individual shall be responsible for providing positive control over the activities within the area.
Contrary to the above, on January 21, 1986, a worker was permitted to work in a high radiation area, the purification filter room, without being provided with a referenced radiation monitoring device and without having his activities within the area under positive control by an individual qualified in radiation protection procedures.
This is a Severity Level IV violation (Supplement IV).
Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within thirty days of the date of this Notice a written statement or explanation in reply, including for each item of noncompliance:
(1) corrective action taken and the results achieved; (2) corrective action to be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.
Consideration may be given to extending your response time for good cause shown.
s/IM
/W 4
Dated W. D. Shafer, Chief Emergency Preparedness and Radiological Protection Branch i
HUE lDOCKOO13 gso334 05000255 G
-