MONTHYEARML20062E8331990-10-31031 October 1990 Monthly Operating Rept for Oct 1990 for Yankee Atomic Power Station ML20062B6751990-09-30030 September 1990 Monthly Operating Rept for Yankee Atomic Power Station for Sept 1990 ML20059E8001990-08-31031 August 1990 Monthly Operating Rept for Aug 1990 for Yankee Atomic Power Station ML20055F6751990-06-30030 June 1990 Monthly Operating Rept for June 1990 for Yankee Atomic Power Station ML20247N8211989-08-31031 August 1989 Monthly Operating Rept for Aug 1989 for Yankee Atomic Nuclear Power Station ML20245F9621989-07-31031 July 1989 Monthly Operating Rept for Jul 1989 for Yankee Atomic Power Station ML20247D9811989-06-30030 June 1989 Monthly Operating Rept for June 1989 for Yankee Atomic Power Station ML20245G6061989-05-31031 May 1989 Monthly Operating Rept for May 1989 for Yankee Atomic Power Station ML20247D0921989-04-30030 April 1989 Monthly Operating Rept for Apr 1989 for Yankee Atomic Power Station ML20244C7011989-03-31031 March 1989 Monthly Operating Rept for Mar 1989 for Yankee Atomic Power Station ML20236A9261989-02-28028 February 1989 Monthly Operating Rept for Feb 1989 for Yankee Atomic Power Station ML20206A8081988-10-31031 October 1988 Monthly Operating Rept for Oct 1988 for Yankee Rowe ML20207P1311988-09-30030 September 1988 Monthly Operating Rept for Sept 1988 for Yankee Atomic Nuclear Power Station ML20154E6491988-08-31031 August 1988 Monthly Operating Rept for Aug 1988 for Yankee Atomic Nuclear Station ML20207E8551988-07-31031 July 1988 Monthly Operating Rept for Jul 1988 for Yankee Atomic Power Station ML20151E4971988-06-30030 June 1988 Monthly Operating Rept for June 1988 for Yankee Atomic Power Station ML20155B7631988-05-31031 May 1988 Monthly Statistical Rept 88-05 for May 1988 for Yankee Atomic Nuclear Power Station ML20154E6201988-04-30030 April 1988 Monthly Operating Rept for Apr 1988 ML20151F9101988-03-31031 March 1988 Monthly Statistical Rept 88-03 for Mar 1988 ML20196J9601988-02-29029 February 1988 Monthly Operating Rept for Feb 1988 ML20237A9551987-11-30030 November 1987 Monthly Operating Rept for Nov 1987 ML20236P3291987-10-31031 October 1987 Monthly Operating Rept for Oct 1987 ML20235U8561987-09-30030 September 1987 Monthly Operating Rept for Sept 1987 ML20238E7921987-08-31031 August 1987 Monthly Operating Rept for Aug 1987 ML20237L6201987-07-31031 July 1987 Monthly Operating Rept for Jul 1987 ML20235S4361987-06-30030 June 1987 Monthly Operating Rept for June 1987 ML20215F1031987-05-31031 May 1987 Monthly Operating Rept for May 1987 ML20237K5811987-04-30030 April 1987 Monthly Operating Rept for Apr 1987 ML20237K6651987-03-31031 March 1987 Monthly Operating Rept for Mar 1987 ML20237K5191987-02-28028 February 1987 Monthly Operating Rept for Feb 1987 ML20205C5981987-01-31031 January 1987 Monthly Operating Rept for Jan 1987 ML20212P2951986-12-31031 December 1986 Monthly Operating Rept for Dec 1986 ML20211Q6201986-11-30030 November 1986 Monthly Operating Rept for Nov 1986 ML20212L2451986-10-31031 October 1986 Monthly Operating Rept for Oct 1986 ML20212C7291986-08-31031 August 1986 Monthly Operating Rept for Aug 1986 ML20215C2101986-07-31031 July 1986 Monthly Operating Rept for Jul 1986 ML20214M8701986-06-30030 June 1986 Monthly Operating Rept for June 1986 ML20205D4351986-05-31031 May 1986 Monthly Operating Rept for May 1986 ML20207C2091986-04-30030 April 1986 Monthly Operating Rept for Apr 1986 ML20206D9911986-03-31031 March 1986 Monthly Operating Rept for Mar 1986 ML20197D1251986-02-28028 February 1986 Monthly Operating Rept for Feb 1986 ML20203E1881986-01-31031 January 1986 Monthly Operating Rept for Jan 1986 ML20210F9051985-12-31031 December 1985 Monthly Operating Rept for Dec 1985 ML20137V5701985-11-30030 November 1985 Monthly Operating Rept for Nov 1985 ML20137V5851985-10-31031 October 1985 Revised Monthly Operating Rept for Oct 1985 ML20136G7441985-10-31031 October 1985 Monthly Operating Rept for Oct 1985 ML20138C3091985-09-30030 September 1985 Monthly Operating Rept for Sept 1985 ML20138R8641985-08-31031 August 1985 Monthly Operating Rept for Aug 1985 ML20132G8791985-07-31031 July 1985 Monthly Operating Rept for Jul 1985 ML20135B5091985-06-30030 June 1985 Monthly Operating Rept for June 1985 1990-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217C1311999-10-0808 October 1999 Safety Evaluation Supporting Amend 153 to License DPR-3 ML20211J5111999-08-31031 August 1999 Rev 29 to Yankee Decommissioning QA Program ML20211J3361999-08-27027 August 1999 Safety Evaluation Supporting Amend 152 to License DPR-3 ML20209D5391999-06-22022 June 1999 Rev 29 to Yaec Decommissioning QA Program ML20207F9491999-03-0505 March 1999 Safety Evaluation Supporting Amend 151 to License DPR-3 ML20202H5871999-02-0303 February 1999 Safety Evaluation Supporting Amend 150 to License DPR-3 ML20154P9691998-10-16016 October 1998 Rev 28 to Yankee Atomic Electric Co Decommissioning QA Program ML20249A7901998-06-17017 June 1998 Safety Evaluation Supporting Amend 149 to License DPR-3 ML20216C4581998-02-27027 February 1998 Response to NRC Demand for Info (NRC OI Rept 1-95-050) ML20203L1931998-02-25025 February 1998 Duke Energy Corp,Duke Engineering & Svcs,Inc,Yankee Atomic Small Break LOCA Technical Review Rept ML20203L2451998-02-23023 February 1998 Assessment Rept of Engineering & Technical Work Process Utilized at De&S Bolton Ofc ML20203L1621998-02-18018 February 1998 Rept of Root Cause Assessment Review ML20203L2691998-02-16016 February 1998 Duke Engineering & Svcs Assessment Process Review Rept ML20199B4601998-01-20020 January 1998 Special Rept:On 980105,meteorological Monnitoring Instrumentation for Air Temp Delta T Inoperable for More than 7 Days.Caused by Breakdown in Wiring Between Junction Box at 199 Foot Level.Wiring Replaced ML20203J3001997-12-31031 December 1997 Ynps 1997 Annual Rept ML20217N0981997-08-21021 August 1997 LER 97-S02-00:on 970725,discovered Uncontrolled Safeguards Documents.Caused by Personnel Error.Matls Retrieved & Stored in Safeguards Repositories ML20210H0991997-08-0707 August 1997 LER 97-S01-00:on 970709,potential Compromise of Safeguards Info Occurred.Caused by Human error.Stand-alone Personal Computer & Printer Not Connected to Network,Have Been Located within Text Graphics Svc Dept ML20149K7781997-07-24024 July 1997 Special Rept:On 970520 & 0714,air Temp Delta T Channel Indicated Temp Difference Between Top & Bottom of Meteorological Tower.Caused by Reversed Input Wiring to Channel.Restored Air Temp Delta T Channel Operability ML20141E4671997-05-30030 May 1997 Rev 28 to Operational QA Program ML20135C8461996-12-31031 December 1996 Yankee Nuclear Power Station 1996 Annual Rept ML20132G6771996-12-20020 December 1996 Rev 27 to YOQAP-I-A, Operational QA Program ML20058N4771993-12-20020 December 1993 Rev 0.0 to Yankee Nuclear Power Station Decommissioning Plan ML20059K8491993-12-15015 December 1993 Clarifications to Pages 2,41,43 & 44 of 44 in Section I, Organization of YOQAP-I-A,Rev 24, Operational QA Program ML20059C5011993-10-29029 October 1993 Special Rept:On 931019,meteorological Instrumentation Channel for Delta T Declared Inoperable.Caused by Ceased Aspirator Motor Located at Top of Tower.Motor Replaced ML20056H1741993-06-10010 June 1993 Preliminary Assessment of Potential Human Exposures to Routine Tritium Emissions from Yankee Atomic Electric Co Nuclear Power Facility Located Near Rowe,Ma ML20237F1671993-02-19019 February 1993 Safety Evaluation Supporting Amend 147 to License DPR-3 ML20125C7161992-12-0707 December 1992 Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils Encl ML20198D2541992-05-13013 May 1992 Yankee Nuclear Power Station Certified Fuel Handler Recertification Program ML20198D2481992-05-13013 May 1992 Yankee Nuclear Power Station Certified Fuel Handler Initial Certification Program ML20062H1981990-11-30030 November 1990 Plant Specific Fast Neutron Exposure Evaluations for First 20 Operating Fuel Cycles of Yankee Rowe Reactor ML20058H2841990-11-0303 November 1990 Special Rept:On 901101,control Rod 24 Found Disconnected from Drive Shaft.Drive Shaft Latching Will Be Initiated ML20058F2201990-11-0202 November 1990 Safety Evaluation Accepting Util Response to Generic Ltr 83-28 Re post-trip Review - Data & Info Capability ML20062E8331990-10-31031 October 1990 Monthly Operating Rept for Oct 1990 for Yankee Atomic Power Station ML20058G1471990-10-31031 October 1990 Vol 2 to Star Methodology Application for PWRs Control Rod Ejection Main Steam Line Break ML20058C4061990-10-22022 October 1990 Safety Evaluation Supporting Amend 137 to License DPR-3 ML20062B6751990-09-30030 September 1990 Monthly Operating Rept for Yankee Atomic Power Station for Sept 1990 ML20059G2411990-09-0606 September 1990 Safety Evaluation Supporting Amend 135 to License DPR-3 ML20059E3071990-08-31031 August 1990 Safety Assessment of Yaec 1735, Reactor Pressure Vessel Evaluation Rept for Yankee Nuclear Power Station. Detailed Plan of Action W/Listed Elements Requested within 60 Days After Restart to Demonstrate Ability to Operate Longer ML20059E8001990-08-31031 August 1990 Monthly Operating Rept for Aug 1990 for Yankee Atomic Power Station ML20058P7841990-08-14014 August 1990 Part 21 Rept Re Misapplication of Fluorolube FS-5 Oil in Main Steam Line Pressure Gauges.All Four Indicators Replaced W/Spare Gauges Which Utilize High Temp Silicone Oil ML20058N6581990-08-13013 August 1990 Special Rept Re Diesel Fire Pump & Tank Inoperable for Greater than Seven Days for Draining,Cleaning & Insp.During Period Redundant Pumping Capacity Available Via Two Remaining Electric Driven Fire Pumps ML20058L0321990-08-0202 August 1990 Safety Evaluation Supporting Amend 133 to License DPR-3 ML20058L6651990-08-0202 August 1990 Safety Evaluation Supporting Amend 134 to License DPR-3 ML20056A1961990-08-0101 August 1990 Special Rept:Two Fire Pumps Inoperable at Same Time.Caused by Necessity to Accomplish Surveillance to Verify Capability to Start Pump on Emergency Diesel Generator 3 & Planned 18-month Insp of Diesel Per Tech Specs ML20055G6801990-07-31031 July 1990 Yankee Plant Small Break LOCA Analysis ML20055G7011990-07-31031 July 1990 Yankee Nuclear Power Station Core 21 Performance Analysis ML20055E1591990-07-31031 July 1990 Reactor Pressure Vessel Evaluation Rept ML20055J3221990-07-25025 July 1990 Decommissioning Funding Assurance Rept & Certification ML20055G7051990-07-19019 July 1990 Rev 0 to Yankee Cycle 21 Core Operating Limits Rept ML20055F6751990-06-30030 June 1990 Monthly Operating Rept for June 1990 for Yankee Atomic Power Station 1999-08-31
[Table view] |
Text
._ __
YANKEE ATOMIC NUCLEAR POWER STATION MONTHLY STATISTICAL REPORT 85-05 FOR THE MONTH OF MAY 1985 8508090211 850531 PDR ADOCK 05000029 R PDR h ,bN,
'l '
e i
, \
OPERATING BATA REPORT DOCKET NO. 50-29 DATE 85M05 COMPLETED BY S. NHIPPLE TELEPHONE (617) 872-8100 DPERATING STATUS
- 1. Unit Name: Yankee Rome
- 2. Reporting Period: May,1985
- 3. Licensed Thersal Power ( Mt): 600
- 4. Nameplate Rating (Gross Me): 185
- 5. Design Electrical Rating (Net M el: 175
- 6. Manieus Dependable Capacity (6ross Me): 100
- 7. Marious Dependable Capacity (Net Me): 167
- 8. If Changes Occur in Capacity Ratings (Itees Number 3 Through 7) Since Last Report, Give Reasons:
- 9. Power Level To Nhich Restricted. If Any (Net Me):
- 10. Reasons For Restrictions. If Any:
This Month Yr.-to-Date Cuaulative
- 11. Hours in Reporting Period 744.00 3,623.00 ---
- 12. Number of Hours Reactor Nas Critical 744.00 3,623.00 171,546.10
- 13. Reactor Reserve Shutdown Hours 0.00 0.00 0.00
- 14. Hours Generator On-Line 744.00 3,623.00 166,807.42
- 15. Unit Reserve Shutdown Hours 0.00 0.00 0.00
- 16. Gross Thereal Energy Generated (MNH) 427,101.00 2,124,404.00 90,615,056.52
- 17. Gross Electrical Energy Generated (MH) 128,622.90 646,346.60 27,465,149.90
- 18. Net Electrical Energy Generated ( MH) 120,383.66 606,034.33 25,700,584.78
- 19. Unit Service Factor 100.00 100.00 77.51
- 20. Unit Availability Factor 100.00 100.00 77.51
- 21. Unit Capacity Factor (Using MDC Net) 96.89 100.16 73.49
- 22. Unit Capacity Factor (using DER Net) 92.46 95.59 70.04
- 23. Unit Forced Dutage Rate 0.00 0.00 5.36
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Dur #ior of Each):
Core IVill Refueling - October 19, 1985 - 6 weeks
- 25. If Shutdown At End of Report Period, Estinated Date of Stetup:
- 26. Units in Test Status (Prior to Coseercial Operation): Forecast Achieved INITIAL CRITICALITY INITIALELECTRICITY COMERCIAL DPERATION
nVERAGE DAILY W ii POER LEVEL DOCKET NO. 50-29 UNIT YANKEE R0WE DATE 850605 COMPLETED BY S. WHIPPLE TELEPHONE (6171 872-8100 MONTH MAY,1985 DAY AVERA6E DAILY POWER LEVEL DAY AVERA6E DAILY POWER LEVEL (MWe-Net)
(Nue-Net) 17 170.0 i 168.8 18 169.7 2 168.7 19 169.1 3 18.7 20 168.9 4 3 21 168.6 5 <!. & .
22 169.1 '
6 100.4 23 169.8 7 161.4 24 169.9 8 170.2 25 169.4 9 170.1 26 168.7 to 169.9 27 168.3 11 169.8 28 168.6 12 170.7 29 168.8 13 170.8 170.7 30 168.7 14 31 168.6 15 170.7 16 170.3 INSTRUCTIONS On this forsat, list the average daily unit power level in MWe-Net for each day in the reporting sonth.
l t Compute to the nearest whole segawatt.
i
WIT SNUTDOWS AND PONER REDUCTIONS DOCKET NO. 50-29 WIT YAR EE RONE REPORT MONTH MAY,1995 DATE B50605 CONPLETED BY S. WIPPLE TELEPHONE (617) 872-8100 Method Licensee Cause & Corrective i Duration 2 Of Shutting Event Systes Component Action to No. Date Type (Hours) Reason Down Reactor 3 Report 4 Code 4 Code 5 Prevent Recurrence 85-6 5/4/85 S 84.00 Bf 1 N/A N/A N/A N/A
- Power reduction to conduct throttle valve test and condenser tube cleaning.
I 2 3 4 F: Forced Reason: Method: Exhibit 6-Instructions S: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scras. Entry Sheets for License C-Refueling 3-Automatic Scras. Event Report (LER) File D-Regulatory Restriction 4-Other (Explain) (NURES-0161)
E-Operator Training & Licensed Examination F-Administrative 5 6-Operational Error (Explain) Exhibit 1 - Saee Source H-Other (Explain) l
DOCKET 110. 50-29 Wii YANKEE RONE DATE 950605 C0ffPLETED BY S.lellPPLE TELEPHONE (617) 872-9100 I
I REPORTIIOllTH MY,1995 '
SINelARY OF OPERATill6 EIPERIEllCES i'
05/04/85 0001 Power reduced for throttle valve test and condenser tube cleaning.
l l
l l
l 4
i-w.+-.vg-ev ~--=>w...m-,, ,as,-r= --e, ,a-.y
.& Te'epho"e (6 ") ' -8'o0 YANKEE ATOMIC ELECTRIC COMPANY TMlX 710-380-7619 1671 Worcester Road Framingham, Massachusetts 01701 at?-- ,. .
i.
li .: Jit EE ./
June 5, 1985 17.R.4.2 FYR 85-65 United States Nuclear Regulatory Commission Director, Office of Management Information and Program Control Washington, D.C. 20555
Dear Sir:
Submitted herewith is the Monthly Statistical Report for the Yankee Atomic Power Station for the month of May 1985.
Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY L. H. Heider Vice President / Manager of Operations LHH/ba cc: Region I g Office of Inspection and Enforcement
'(,