YANKEE ATOMIC NUCLEAR POWER STATION MONTHLY STATISTICAL REPORT 87-04 FOR THE MONTH OF April, 1987 i
i 1
1
-[
8709190321 870430
[
i PDR ADOCK 05000029 R
PDR..
{
r 1
1 c.
4 '
DPERATIN6 DATA REPORT DOCKET NO.
50-29 DATE 870505 COMPLETEDBY S. WHIPPLE TELEPHONE (617) 872-8100 OPERATING STATUS 1.
Unit Nase Yankee Rome 2.
Reportin0 Period: April,1987 3.
Licensed Thereal Power (MWti:
600 4.
Naseplate Rating (Bross MWeh 185 5.
Design Electrical Rating (Net MWe):
175 6.
Maxieue Dependable Capacity (Gross MWe): 180
. 7, Maxieue Dependable Capacity (Net Mke):
167 8.
If Changes Occur in Capacity Ratings (Itees Nuober 3 Through 7) Since Last Report, Sive Reasons:
_=.....
9.
Power Level To Which Restricted. If Any (Net MWeb
- 10. Reasons For Restrictions. If Any:
_........=___
This Month Yr.-to-Date Cueulative
- 11. Hours in Reporting Period 719.00 2,879.00
- 12. Nueber of Hours Reactor Was Critical 719.00 2,834.23 106,699.23 1
- 13. Reactor Reserve Shutdown Hours 0.00 0.00 0.00
- 14. Hours Generator On-Line 719.00 2,823.23 181,804.18 -
- 15. Unit Reserve Shutdown Hours 0.00 0.00 0.00
- 16. Gross Thereal Energy Generated (MWH) 349,840.00 1,572,417.00 99,154,362.52
- 17. Gross Electrical Energy Generated (MWH) 104,843.20 477,262.80 30,046,807.40
- 18. Net Electrical Energy Generated (MWH) 97,011.00 445,643.91 28,114,584.11
- 19. Unit Service Factor 100.00 98.06 78.37
- 20. Unit Availability Fatter 100.00 98.06 78.37
- 21. Unit Capacity Factor (Using MDC Net) 80.79 92.69 74.43
- 22. Unit Capacity Factor (Using DER Net) 77.10 88.45 70.94
- 23. Unit Forced Outage Fate 0.00 1.94 5.18
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each): Core 19 Refueling: May 2, 1987; 6 weeks.
- 25. If Shutdown At End of Report Period, Estimated Date of Startupt
- 26. Units in Test Status (Prior to Coseercial Operation):
Forecast Achieved
)
i INITIAL CRii!CALITY i
INITIAL ELECTRICliY COMMERCIAL OPERA 110N d
h '\\,
i 1
l o '
AVERABE DAILY UNIT POWER LEVEL
{
DOCKET NO.
50-29 UNIT YANKEE R0WE DATE 870505 COMPLETED BY S. WHIPPLE TELEPHONE (617) 872-8100 MONTH APR1L,1987 DAY AVERASE DAILY POWER LEVEL DAY AVERABE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1 146.8 17 133.8 2
145.9 18 133.0 3
145.0 19 132.2 4
144.3 20 131.4 5
143.6 21 130.8 6
142.8 22 129.9 7
142.1 23 129.0 8
141.2 24 128.1 9
140.3 25 127.2 10 139.5 26 126.4 11 138.7 27 125.0 12 137.9 28 124.1 13 136.9 29 123.4 14 136.2 30 122.7 15 135.3 31 16 134.5 i
]N51RUC110NS On this format, list the average daily unit power level in MWe-het for each day in the reporting scrith.
Compute to the nearest whole negawatt.
I l
l l
,,4
- f. :
c.
,a...:
'e.
j.
UNIT SHUTDONNS AND PONER REDUCTIONS
- DOCKET NO.
50 UNIT
~ YANKEE RONE' -
REPORT MC1TH ' APRIL,1987 DATE B70505 COMPLETED BY S. NHIPPLE TELEPHONE (617) 872-8100 Method Licensee Cause & Corrective 1. Duration 2 Of Shutting. Event-Systes ' Component Action to No.
Date Type (Hours) Reason Down Reactor 3 Report i Code 4 Code 5 Prevent Recurrence
.................................... =-
-............_=-
NONE f
................=-_
..............=-
=........=---
=.........
1 2
3 4
F Forced Reason:
Method:
Exhibit 6-Instructions 51 Scheduled A-Equipeent Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scras.
Entry Sheets for License C-Refueling 3-Automatic Scras.
Event Report (LER) File D-RegulatoryRestriction 4-Other (Explain)
(NUREB-0161)
E-Operator Training & Licensed Erasination F-Administrative 5
6-Operatlocal Error (Explain)
Exhibit 1 - Saee Source H-Other (Explain)
l DOCKET NO.
50-29 UNIT YANKEE R0WE DATE 870505 COMPLETED BY S. WHIPPLE TELEPHDNE (617) 072-8100 REPORT MONTH APRIL, 1987
SUMMARY
OF OPERATING EXPERIENCES Continued coastdonn operation all month, i
I l
l l
l l
l l
/
DESIGg 1 ORIGIFf y-.
/{
/
Teteonone (617) 872 8100 Certif100 Twx 110 380 7619 i
YANKEE ATOMIC ELECTRIC COMPANY
-.< m( o y2 1671 Worcester Road, Framingham, Massachusetts 01701 s
May 6, 1987 FYR 87-048 United States Nuclear Regulatory Commission Director, Office of Management Information and Program Control Washington, D.C. 20555
Dear Sir:
Submitted herewith is the monthly Statistical Report for the Yankee Atomic Power Station for the month of April, 1987 Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY
- 1. H. Heider Vice President / Manager of Operations LHH/gbc Enclosure cc: Region I Office of Inspection & Enforcement b