MONTHYEARML20062E8331990-10-31031 October 1990 Monthly Operating Rept for Oct 1990 for Yankee Atomic Power Station ML20062B6751990-09-30030 September 1990 Monthly Operating Rept for Yankee Atomic Power Station for Sept 1990 ML20059E8001990-08-31031 August 1990 Monthly Operating Rept for Aug 1990 for Yankee Atomic Power Station ML20055F6751990-06-30030 June 1990 Monthly Operating Rept for June 1990 for Yankee Atomic Power Station ML20247N8211989-08-31031 August 1989 Monthly Operating Rept for Aug 1989 for Yankee Atomic Nuclear Power Station ML20245F9621989-07-31031 July 1989 Monthly Operating Rept for Jul 1989 for Yankee Atomic Power Station ML20247D9811989-06-30030 June 1989 Monthly Operating Rept for June 1989 for Yankee Atomic Power Station ML20245G6061989-05-31031 May 1989 Monthly Operating Rept for May 1989 for Yankee Atomic Power Station ML20247D0921989-04-30030 April 1989 Monthly Operating Rept for Apr 1989 for Yankee Atomic Power Station ML20244C7011989-03-31031 March 1989 Monthly Operating Rept for Mar 1989 for Yankee Atomic Power Station ML20236A9261989-02-28028 February 1989 Monthly Operating Rept for Feb 1989 for Yankee Atomic Power Station ML20206A8081988-10-31031 October 1988 Monthly Operating Rept for Oct 1988 for Yankee Rowe ML20207P1311988-09-30030 September 1988 Monthly Operating Rept for Sept 1988 for Yankee Atomic Nuclear Power Station ML20154E6491988-08-31031 August 1988 Monthly Operating Rept for Aug 1988 for Yankee Atomic Nuclear Station ML20207E8551988-07-31031 July 1988 Monthly Operating Rept for Jul 1988 for Yankee Atomic Power Station ML20151E4971988-06-30030 June 1988 Monthly Operating Rept for June 1988 for Yankee Atomic Power Station ML20155B7631988-05-31031 May 1988 Monthly Statistical Rept 88-05 for May 1988 for Yankee Atomic Nuclear Power Station ML20154E6201988-04-30030 April 1988 Monthly Operating Rept for Apr 1988 ML20151F9101988-03-31031 March 1988 Monthly Statistical Rept 88-03 for Mar 1988 ML20196J9601988-02-29029 February 1988 Monthly Operating Rept for Feb 1988 ML20237A9551987-11-30030 November 1987 Monthly Operating Rept for Nov 1987 ML20236P3291987-10-31031 October 1987 Monthly Operating Rept for Oct 1987 ML20235U8561987-09-30030 September 1987 Monthly Operating Rept for Sept 1987 ML20238E7921987-08-31031 August 1987 Monthly Operating Rept for Aug 1987 ML20237L6201987-07-31031 July 1987 Monthly Operating Rept for Jul 1987 ML20235S4361987-06-30030 June 1987 Monthly Operating Rept for June 1987 ML20215F1031987-05-31031 May 1987 Monthly Operating Rept for May 1987 ML20237K5811987-04-30030 April 1987 Monthly Operating Rept for Apr 1987 ML20237K6651987-03-31031 March 1987 Monthly Operating Rept for Mar 1987 ML20237K5191987-02-28028 February 1987 Monthly Operating Rept for Feb 1987 ML20205C5981987-01-31031 January 1987 Monthly Operating Rept for Jan 1987 ML20212P2951986-12-31031 December 1986 Monthly Operating Rept for Dec 1986 ML20211Q6201986-11-30030 November 1986 Monthly Operating Rept for Nov 1986 ML20212L2451986-10-31031 October 1986 Monthly Operating Rept for Oct 1986 ML20212C7291986-08-31031 August 1986 Monthly Operating Rept for Aug 1986 ML20215C2101986-07-31031 July 1986 Monthly Operating Rept for Jul 1986 ML20214M8701986-06-30030 June 1986 Monthly Operating Rept for June 1986 ML20205D4351986-05-31031 May 1986 Monthly Operating Rept for May 1986 ML20207C2091986-04-30030 April 1986 Monthly Operating Rept for Apr 1986 ML20206D9911986-03-31031 March 1986 Monthly Operating Rept for Mar 1986 ML20197D1251986-02-28028 February 1986 Monthly Operating Rept for Feb 1986 ML20203E1881986-01-31031 January 1986 Monthly Operating Rept for Jan 1986 ML20210F9051985-12-31031 December 1985 Monthly Operating Rept for Dec 1985 ML20137V5701985-11-30030 November 1985 Monthly Operating Rept for Nov 1985 ML20137V5851985-10-31031 October 1985 Revised Monthly Operating Rept for Oct 1985 ML20136G7441985-10-31031 October 1985 Monthly Operating Rept for Oct 1985 ML20138C3091985-09-30030 September 1985 Monthly Operating Rept for Sept 1985 ML20138R8641985-08-31031 August 1985 Monthly Operating Rept for Aug 1985 ML20132G8791985-07-31031 July 1985 Monthly Operating Rept for Jul 1985 ML20135B5091985-06-30030 June 1985 Monthly Operating Rept for June 1985 1990-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217C1311999-10-0808 October 1999 Safety Evaluation Supporting Amend 153 to License DPR-3 ML20211J5111999-08-31031 August 1999 Rev 29 to Yankee Decommissioning QA Program ML20211J3361999-08-27027 August 1999 Safety Evaluation Supporting Amend 152 to License DPR-3 ML20209D5391999-06-22022 June 1999 Rev 29 to Yaec Decommissioning QA Program ML20207F9491999-03-0505 March 1999 Safety Evaluation Supporting Amend 151 to License DPR-3 ML20202H5871999-02-0303 February 1999 Safety Evaluation Supporting Amend 150 to License DPR-3 ML20154P9691998-10-16016 October 1998 Rev 28 to Yankee Atomic Electric Co Decommissioning QA Program ML20249A7901998-06-17017 June 1998 Safety Evaluation Supporting Amend 149 to License DPR-3 ML20216C4581998-02-27027 February 1998 Response to NRC Demand for Info (NRC OI Rept 1-95-050) ML20203L1931998-02-25025 February 1998 Duke Energy Corp,Duke Engineering & Svcs,Inc,Yankee Atomic Small Break LOCA Technical Review Rept ML20203L2451998-02-23023 February 1998 Assessment Rept of Engineering & Technical Work Process Utilized at De&S Bolton Ofc ML20203L1621998-02-18018 February 1998 Rept of Root Cause Assessment Review ML20203L2691998-02-16016 February 1998 Duke Engineering & Svcs Assessment Process Review Rept ML20199B4601998-01-20020 January 1998 Special Rept:On 980105,meteorological Monnitoring Instrumentation for Air Temp Delta T Inoperable for More than 7 Days.Caused by Breakdown in Wiring Between Junction Box at 199 Foot Level.Wiring Replaced ML20203J3001997-12-31031 December 1997 Ynps 1997 Annual Rept ML20217N0981997-08-21021 August 1997 LER 97-S02-00:on 970725,discovered Uncontrolled Safeguards Documents.Caused by Personnel Error.Matls Retrieved & Stored in Safeguards Repositories ML20210H0991997-08-0707 August 1997 LER 97-S01-00:on 970709,potential Compromise of Safeguards Info Occurred.Caused by Human error.Stand-alone Personal Computer & Printer Not Connected to Network,Have Been Located within Text Graphics Svc Dept ML20149K7781997-07-24024 July 1997 Special Rept:On 970520 & 0714,air Temp Delta T Channel Indicated Temp Difference Between Top & Bottom of Meteorological Tower.Caused by Reversed Input Wiring to Channel.Restored Air Temp Delta T Channel Operability ML20141E4671997-05-30030 May 1997 Rev 28 to Operational QA Program ML20135C8461996-12-31031 December 1996 Yankee Nuclear Power Station 1996 Annual Rept ML20132G6771996-12-20020 December 1996 Rev 27 to YOQAP-I-A, Operational QA Program ML20058N4771993-12-20020 December 1993 Rev 0.0 to Yankee Nuclear Power Station Decommissioning Plan ML20059K8491993-12-15015 December 1993 Clarifications to Pages 2,41,43 & 44 of 44 in Section I, Organization of YOQAP-I-A,Rev 24, Operational QA Program ML20059C5011993-10-29029 October 1993 Special Rept:On 931019,meteorological Instrumentation Channel for Delta T Declared Inoperable.Caused by Ceased Aspirator Motor Located at Top of Tower.Motor Replaced ML20056H1741993-06-10010 June 1993 Preliminary Assessment of Potential Human Exposures to Routine Tritium Emissions from Yankee Atomic Electric Co Nuclear Power Facility Located Near Rowe,Ma ML20237F1671993-02-19019 February 1993 Safety Evaluation Supporting Amend 147 to License DPR-3 ML20125C7161992-12-0707 December 1992 Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils Encl ML20198D2541992-05-13013 May 1992 Yankee Nuclear Power Station Certified Fuel Handler Recertification Program ML20198D2481992-05-13013 May 1992 Yankee Nuclear Power Station Certified Fuel Handler Initial Certification Program ML20062H1981990-11-30030 November 1990 Plant Specific Fast Neutron Exposure Evaluations for First 20 Operating Fuel Cycles of Yankee Rowe Reactor ML20058H2841990-11-0303 November 1990 Special Rept:On 901101,control Rod 24 Found Disconnected from Drive Shaft.Drive Shaft Latching Will Be Initiated ML20058F2201990-11-0202 November 1990 Safety Evaluation Accepting Util Response to Generic Ltr 83-28 Re post-trip Review - Data & Info Capability ML20062E8331990-10-31031 October 1990 Monthly Operating Rept for Oct 1990 for Yankee Atomic Power Station ML20058G1471990-10-31031 October 1990 Vol 2 to Star Methodology Application for PWRs Control Rod Ejection Main Steam Line Break ML20058C4061990-10-22022 October 1990 Safety Evaluation Supporting Amend 137 to License DPR-3 ML20062B6751990-09-30030 September 1990 Monthly Operating Rept for Yankee Atomic Power Station for Sept 1990 ML20059G2411990-09-0606 September 1990 Safety Evaluation Supporting Amend 135 to License DPR-3 ML20059E3071990-08-31031 August 1990 Safety Assessment of Yaec 1735, Reactor Pressure Vessel Evaluation Rept for Yankee Nuclear Power Station. Detailed Plan of Action W/Listed Elements Requested within 60 Days After Restart to Demonstrate Ability to Operate Longer ML20059E8001990-08-31031 August 1990 Monthly Operating Rept for Aug 1990 for Yankee Atomic Power Station ML20058P7841990-08-14014 August 1990 Part 21 Rept Re Misapplication of Fluorolube FS-5 Oil in Main Steam Line Pressure Gauges.All Four Indicators Replaced W/Spare Gauges Which Utilize High Temp Silicone Oil ML20058N6581990-08-13013 August 1990 Special Rept Re Diesel Fire Pump & Tank Inoperable for Greater than Seven Days for Draining,Cleaning & Insp.During Period Redundant Pumping Capacity Available Via Two Remaining Electric Driven Fire Pumps ML20058L0321990-08-0202 August 1990 Safety Evaluation Supporting Amend 133 to License DPR-3 ML20058L6651990-08-0202 August 1990 Safety Evaluation Supporting Amend 134 to License DPR-3 ML20056A1961990-08-0101 August 1990 Special Rept:Two Fire Pumps Inoperable at Same Time.Caused by Necessity to Accomplish Surveillance to Verify Capability to Start Pump on Emergency Diesel Generator 3 & Planned 18-month Insp of Diesel Per Tech Specs ML20055G6801990-07-31031 July 1990 Yankee Plant Small Break LOCA Analysis ML20055G7011990-07-31031 July 1990 Yankee Nuclear Power Station Core 21 Performance Analysis ML20055E1591990-07-31031 July 1990 Reactor Pressure Vessel Evaluation Rept ML20055J3221990-07-25025 July 1990 Decommissioning Funding Assurance Rept & Certification ML20055G7051990-07-19019 July 1990 Rev 0 to Yankee Cycle 21 Core Operating Limits Rept ML20055F6751990-06-30030 June 1990 Monthly Operating Rept for June 1990 for Yankee Atomic Power Station 1999-08-31
[Table view] |
Text
-_ ,
Oh YANKEE ATOMIC NUCLEAR POWER STATION MONTHLY STATISTICAL REPORT 86-06 FOR THE MONTH OF JUNE, 1986 8609110341 860630
}0 PDR ADOCK 05000029 i{g R PDR
4 OPERATING DATA REPORT BOCKETNO. 50-29 BATE 860708 COMPLETEDBY S. UNIPPLE TELEPHINIE (617) 872-8100 OPERATING STATUS
- 1. Unit Nase: Yankee Rome
- 2. Reporting Period: June,1986
- 3. Licensed Thereal Power (INit): 600
- 4. Naseplate Rating (Gross Inle): 185
- 5. Design Electrical Rating (Net inle): 175
- 6. Marisue Dependable Capacity (6ross INie): 180
- 7. Maxinus Dependable Capacity (llet infel: 167
- 8. If Changes Occur in Capacity Ratings (itses llueber 3 Through 7) Since Last Report, 6ive Reasons:
- 9. Power Level To Ilhich Restricted. If Any (Net Mlle):
- 10. Reasons For Restrictions. If Any:
Thisllonth Yr.-to-Date Cuaulative
- 11. Hours in Reporting Period 720.00 4,343.00
- 12. Nuaber of Hours Reactor Was Critical 392.68 4,015.68 179,537.16
- 13. Reactor Reserve Shutdown Hours 0.00 0.00 0.00
- 14. Hours Generator On-Line 388.22 4,011.22 174,669.93
- 15. Unit Reserve Shutdown Wurs 0.00 0.00 0.00
- 16. Gross Thersal Energy Generated (MUH) 213,153.00 2,362,580.00 95,043,196.52
- 17. Gross Electrical Energy Benerated (MilH) 64,099.80 719,982.40 28,802,670.20
- 18. Net Electrical Energy Generated (MilH) 59,814.12 674,504.74 26,950,723.91
- 19. Unit Service Factor 53.92 92.36 77.74
- 20. Unit Availability Factor 53.92 92.36 77.74
- 21. Unit Capacity Factor (Using MDC Net) 49.75 93.00 73.73
- 22. Unit, Capacity Factor (Using DER Net) 47.47 88.75 70.27
- 23. Unit Forced Outage Rate 46.08 7.64 5.30
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
- 25. If Shutdown At End of Report Period, Estiested Date of Startup:
- 26. Units In Test Status (Prior to Cassercial Operation): Forecast Achieved i
INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION
r< 1
^
AVERA6E DAILY Ulili POER LEVEL 80CRET No. 50-29 r WIT YANKEE ROUE HTE . BH708
, C0lFLETED BY S.lellPPLE TELEPHONE 16171 872-6100 MONTH JUNE,1996 9AY AVERAGE DAILY PONER LEVEL DAY AVERA8E DAILY POWER LEVEL (tele-tiet) (flue-liet)
I 143.3 17 169.3 2 0.0 IB !!8.8 '
3 22.4 19 0.0 4 122.1 20 0.0 5 150.5 21 0.0 6 168.4 22 0.0 7 168.9 23 0.0 B 151.2 24 0.0 9 161.9 25 0.0 10 169.3 26 0.0
!! 169.3 27 0.0 12 169.3 20 0.0 13 146.7 29 0.0 14 130.9 30 0.0 15 160.5 31 16 169.4 e>
INSTRUCT 10NS On this format, list the average daily unit power leve! '. llle-liet for each day in the reporting conth.
Coepute to the nearest whole negawatt.
e UNIT SHUTIO N S AND POWER REDUCTIONS 80(*ET NO. 50-29 151T YAIE(EE RONE REPORT MONTH JUNE,1986 BATE 860706 COMPLETED BY S. MIPPLE.
TELEPHOE (617) 872-6100 Method Licensee Casse & Corrective i Duration 2 ff Shutting Event Systes Component Action to No. Date Type (Hours) Reason 'han Peactor 3 Report I Code 4 Code 5 Prevent Recurrence 86-1 6/1/86 F 41.70 A 3 86-004 SN LC0 Heater Drain Tank Level Control Channel power supply f ailed and was replaced. (lightning stora)
B6-2 6/13/86 F 63.25 A 1 N/A N/A N/A Power reduction to repair leak in packing gland of BFP.
B6-3 6/18/86 F 290.00 A 1 N/A N/A N/A Leak in S/6 blowdoun line was discovered and repaired.
1 2 3 4 F: Forced Reason: Method: Exhibit 6-Instructions 5: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scras. Entry Sheets for License C-Refueling 3-Automatic Scras. Event Report (LER) File D-Regulatory Restriction 4-Other (Explain) (NUREG-0161)
E-Operator Training & Licensed Exasination F-Administrative 5 6-Operational Error (Explain) Exhibit 1 - Saee Source H-Other (Explain) i l
e l
B0CKET 110. 50-21 tilli YANKEE RONE DATE 860708 EOMPLETED BY S. INilPPLE ,
TELEPHONE (617) 172-0100
-a REPORTIIONTH JUNE,1966 l
SumlARY OF OPERATING EXPERIENCES 6/1/86 Reactor scras due to lightning stors.
6/3/86 Reactor startup and phase to grid.
6/13/96 Reduced load to repair Boiler Feed Puap.
6/19/86 Shutdown to repair S/6 Bloedoun line leak.
1 0
?
l l
0
' T*':ph o"' (* ") * ' ~* ' 0 YANKEE ATOMIC ELECTRIC COMPANY TWX 710-380-7619
-. ' " < . 1671 Worcester Road, Framingham, Massachusetts 01701 DCC 86-067 e f. .. i. ) 17.R4.2
, I /-.) J K 121]: .--
July 8, 1986 ,
FYR 86-066 United States Nuclear Regulatory Commission Director, Office of Management Information and Program Control Washington, D.C. 20555
Dear Sir:
Submitted herewith is the Monthly Statistical Report for the Yankee Atomic Power Station for the month of June, 1986.
Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY j' f 4 t' L. H. Heider Vice President / Manager of Operations LHH/kmc Enclosure cc: Region I Office of Inspection & Enforcement
'\'