Text
. ,
T.S.6.9.1.6 1
PIIILADELPIIIA ELECTRIC COMPANY 3921048250 !
1 LIMERICK GENERATING STATION P. O. BOX 2XO <
l SANA ~lOGA, PA 19464-2XO (215) 327-1200, EXT. 3000 G Docket Nos. 50-352 U$R.gEf uwnex centnArmo srAnon 50-353 License Nos. NPF-39 NPF-85 U. 6. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Subjec.: Limerick Generating Station Monthly Operating Report For Units 1 and 2 Enclosed n; the monthly operating reports for Limerick Units 1 and 2 for the month of September, 1992 forwarded pursuant to Technical Specification 6.9.1.6. Also enclosed ~is Revision 1 to.
the July and August, 1992 reports for Limerick Unit 1, Vnich corrects the Forced Outage Rate figures (line 23). This error occurred as a result of an incorrect entry of refueling outage hours as forced hours. We regret any inconvenience this may have caused.
Very truly yours,
/ f O
KWM/dtc Enclosures cc: T. T. Martin, Administrator, Region I, USNRC (w/ enclosures)
T. J. Kenny, USNRC Senior Resident inspector LGS (w/ enclosures) 9210190355 920930 PDR ADOCK 05000352 R
s o u u c .s PDR [MY iji
.g - _ . .
3921048250 Docket No. #50-352 Attachment to Monthly Operating Report for' September 1992 LIMERICK GENERATING STATION UNIT 1 SEP'. SMBER 1 THROUGH SEPTEMBER 30, 1992 I. NARRATIVE
SUMMARY
OF OPERATING EXPERIENCES Limerick Unit 1 began the raonth of September at 100% of rated thermal power. On Friday, September 4, reactor power was briefly reduced to 92% of rated to perform Main Turbine Control Valve testing. On Sunday, Septembar 13, power was bri e fly reduced to 97% to support a Control Rod pattern adjustment. On Wednesday, September 3 0, the Sodium 24 Tracer Test results were entered into the Plant Process Computer, resulting in a reactor power adjustment of approximately 1.36%
equating to a 14.9 Megawatt electric DIWe) output gain. Unit 1 ended this operating period at a nominal 100% of rated thermal power.
II. CHALLENGES TO MAIN STEAM SAFETY RELIEF VALVES There were nm challenges to the Main Steam Safety Eelief Values during the month.
op r t.gex1 l
1 I
4 l
' > w * " ^ t ,i
- c * ,[ ,
1I l, ,
~ .
s' .
n tJ..
e f.
jr
}Qgl gU j- 1 ~
'A- d p}
7J L
_ _ . Y 0 _ E
_ _ . N 2 V
_ . . A . N 3 E
_ . P . O 3 . L
. _ M. I _
O_'
._C _
T A N_
_ R E <
_ _ _ . T I W
. . . S C_ O)
- . _ C.
I S_ PT N.
1 _ R . G E E 7 4 9 5 6 1 6 8 6 2 8 2 7
_ - ._ . T . R N T YN 2 2 2 3 2 2 3 3 3 3 2 3 3 5 T _ . O L- 0 0 0 I .
N 2 . L C.
E.
S I
I T
A X.
E. IE AW 1
0 1 1 1 0
1 0 0
'e 1 0
1 0
1 0 0 0 0 1 1 1 1 0
1
. . E . V R 0. DW
_ . U.9.9_ . RTE (
_ . 1 _ A . EI N 0 __ E
_ . I . PNE 2_
1 G
. , . H. UUG -_ A 8 P KS 7 _ R L
2 .K 5
3 C
I
.R .
E.D E.CESSC L
MTEI SK 2 _
3 E
V A
E V
E R .
E .B.
.O A .
L.LOIE RNR RPSM
) _
5_
1 _
L 0 _. I M.T 5_L.C,O_P.AEUI I
H MRSL 2
(
Y A
7 5 9 0
2 2 1 2 2
3 2
4 2
5 2
6 7 2
8 9 0 1 1 2 2 2 3 R' D E .
T E Y E W O I T . N N O N N A A O P U D P H T M P T E .O E
_ I K C L L N C E E U O T V D E Y L L
I R A E
. D w O)
E PT G E 8 4 4 6 4 8 7 5 4 9 1 7 4' 5 4 1 A 2 YN 2 3 2 1 2 2 2 2 2 1 3 3 3' 3 3 3 R 9 L - 0 0 0 0 0 0 0 0 0 0 0 0 C 0 0 0 E 9 IE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V
1 A*
A DV k _. (
E ~ E B - G
- h. A E . R T _ E P . V E. A S.
H T Y 1 2 3 4 5 6 7 E 9 0 1 2 3 4 5 6 N A 1 1 1 1 1 1 1 O D
. M t , ' , ' t $ 1
2' v
, -er 1 -t CPdRATING DATA REPORT-
..} g : VG Q. gq n'
'n A o GI
'ET NO. 50 - 352 -
- ?
DATE OCTOBER B. 1992 COMPLETED BV PHILADELPHIA ELECTRIC COMPANY *
, {
KARL WECK REPORTS SJPERVISOR ~>
BUSINESS UNIT '
LIMERICK GENERATING STATION -
TELEPHONE (215) 327-1200 EXTEk: ION 3320 '!
OP. * .V STATUS'
--...--. ...---. --- --.---.._---.----- -_- ...... ^b 1 UNIT Fo..Er L!WER~CA UNIT 1 1 NO'"5 -
THERE WERE NO LOAD DROPS- l
.....- _-..--__.. _ __---_... . . ; l
- 2. REPORTING PERIOD: SEPTEMBER. 1992 i GREATER THAN 20%. 1 .
- 3. LICENSED THERMAL PCwER(MWT): 3293 ! .{
4 NAMEPLATE RATING (GROSS WWE): 1138 i
.._.-..----.--. ; .e
- 5. DESIGN ELECTRICAL RATING (NET kNE): 1055 1
__------. j
- 6. MAXIMUM . DEPENDABLE CAPACITV (GROSS MwE): 1092 i !
l l 1055 I 7 MAXIMUM DEPENDABLE CAPACITY ( N ET **wE ) : l 't B. IF ' CHA NGE S OCCLn IN CAPACITY RATINGS (ITEMS NUWSER 3 T'4POUGH 7) SINCE LAST REPORT. G!VE RC4 SONS:
- 9. POWER LEVEL TO wHICH RESTRICTED. IF ANv (NET vwE): '
- 10. REASONS FC2 RESTRIC7 IONS. IF ANY:
i THIS WONTH .$-TO-DATE CUwut.ATIVE.
i i. HOURS IN REPORT!NG PERIOD 720 6.57E 58.415
- - - ~~-----_ - .--_. -___. --.--- _____
- 12. NuuSER OF HOURS REACTOR WAS CRITICAL 720.0 4.03 4
- 45.340.2 13.' REACTOR RsSERVE. SHUTDOWN HOURS 0.0 0.0 0.0 14 HOURS GENERATOR ON-LINE 720.0 3.907.3 44.349.2
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 -
16.-GROSS THERMAL ENERGY GENERATED (MWH) 2_.367.818 12.540.899 134.529.815
- ' 17.. GROSS FLECTRICAL ENERGY GENERATED (wwH) 769.330 4.088.040 43.588.980 i ;
~18. NET ELECTRICAL ENERGV GENERATED (uwH). 741.631 3.926.753 41.738,209 j PAGE 1 OF 2 i
_-4 _ . r . . , , - ~
v ,j 1 I.rn a
OPcRATING OATA REPORT'(CONTINUED) -DOCKET NO. 50 .' - ' 3 3 2 - ..
I ihh DATE OCTOBER 6 1992- ' '
fj THIS WONTH VR-TO-D*.TE CUMULATIVE
, ^!
19, tJNIT'5ERVICE FACTOR 100.0 C9/4 75.9
- 20. UNIT AVAILASILITY FACTOR 100.0- 59.4 75.9 b
- 21. UNIT CAPACITY FACTOR.(USING MDC NET) 97.6 56 6 67.7 j 22. UNIT CAPACITY.. FACTOR (USING DER NET) 97.6 56.6 67.7
.____~_._ __. ..___ .____. _ _ . . _ _ _ . _ . .
- -23. UNIT PORCED OUTAGE RATE 0.0 14.7 '5.S-
.. ___-...__ ... _........' . . . . . . . . . .-4
, 24 SHUTDOWNS SCHEDULED OV'1 NEXT 6 ttONTHS (TvFE..DATE.'AND DURATION'OF EACH): 'l 25 IF $<4UTDOWN AT END OF REPORT PERIOD. ESTIMATED'DATE OF-STARTUP:
26 UNITS.IN TEST STATUS (PR aR TO COMMERCIAL. OPERATION): FORECAST ACHIEVED INITIAL rICALITV 12/19/84 12/22/84 ,
, INITIAL ELECTRICITV- MID AFRIL 85 4/13/05 COMMERCIAL OPERATION 15"' Q~ 9 86 2/01/86 '
l a
PAGE'2 OF 2 '}
_ , ., . . , . . . _: . , a, , _ .
. m._.. . . . _ .1 ; _. -
' ~ ~ ~ '
39210.4&250 UNIT SHUTDOwMS 00*ER REDUCTIONS DOCME1 No. 50 - 352 UNIT NAME LIVERICK UNIT t DATE OCTOBER 6 1992 -
REPOR' VONTH SEPTEYBER. 1992 COMPLETED BY PHILADCLPHIA ELECTRIC COMPANY KARL WE"* .
REPORTS LJPERVISOR l BUSINESS UNIT I L!vERICh. GENERATING STATION TELEPHONE (215) 327-1200 EXTENSION 1320 l ; ! f METHOD cr LICE ~SEE !SYSTEV*COYrONENTi CAUSE AND CORRECTIVE
{ EVENT I CODE : CODE l ACTION TO i ITYPElDURATIONlREASONISHUTTING DOWN i PREVENT RECURRENCE NO.i DATE [ (1){ (HOURS){ (2) l REACTOR (3) REPORT s ! (4) ! (5) l l < l I I i i 4 N/A HA i VALVES i LOAD WAS REDUCEO 8% FOR MAIN TURBINE 25 920904 l 5 000.0 i B i l l l I l CONTROL VALVE T S'i:NG.
i l l l l I I I I I !
0 1 4 l N/A I R9 1 CONPOD l LOAD WAS REDUCED .s FOR CONTROL EOD 26 920913 i S l 000.0 l l PAT *CAN ADJU ST ME'e '
l l l l l l i l I I t I ----- I ! l 1 l !
i 1 1 - I l l l
(2) (3) (4)
'1' WETHOD EXHIBIT G- INSTRUCTION 3 F - FORCED REASON F04 PREPARATION OF DATA A - EQUIPMENT FAILUTE (EAPLAIN) 1 - MANUAL 5- SCHEDULED 2 - MANJAL SCDAv. ENTRv SHEETS FOR LICENSEE B - MAINTENANCE OR TEST EVENT REPORT (LER)
C - REFUELING 3 AUTOV. TIC SCRAM.
4 - OTHER (dxPLAIN) FILE (NUREG-0161)
D - REGULATORV RESTRICTION E - OPERA 10R TRAINING + LICENSE r.x. AM I N A T I ON (SJ F - ADMINISTRATIVE j G - OPT. RATIONAL ERROD (ENPLAIN) ExH'9IT I - SAME SOURCE l
N - OTeERtEx> LAIN)
. - ~ ._. = ,
3921.048250 Docket No. #50-353-Attachment.to Monthly Operating Report for September 1S92 LIMLAICK GENERATING STATION UNIT 2 SEPTEMBER 1 THROUGH LOPTEMBER 30, 1992 I. NARRATIVE SUMMARi OF OPERATING EXPERIENCES Limerick Unit 2 began the month of September at a nominal 100%
of rated thermal power. On Friday, September 4, reactoc potar was reduceJ t, >2% to support Main Turbine Control Valve testing. On Saturday, September 5, reactor power was further reduced to 75% to perform Flux- Tilt testing and to locate / repair a tube leak in the Main Condenser Circulating-Waterbox. Reactor power was restorod to a nominal 80% on the same day. On Sunday, September 13, power ascension began, power ascension was held at 90% briefly for Condensate Demineralizer regeneration, and then briefly held again at 96.9% due to stalling of the Plant Process Computer printer, C'n Monday, September 14, reactor power ascension was completed at a nominal 98% of rated. On Friday, September 18, power was briefly reduced to 90% to support Reactor Feed Pump Turbine
'I t ip Testing, reactor powec was restored to 96.5% with increc aed core flow. On Saturday, September 19, power was briefly reduced to 90% to support Control Rod pattern adjustment. On Monday, Septerrber 21, the end of full power life was reached. On Wednesday, September 23, power was reduced to 94% to begin tube leak location / repair in t-he -"2B" Main Condenser Circulating WaterBox. On September 25, pcwer was returned to 97% until September 28, w.en power was reduced to 89% to again suppcrt Helium Leak Testing in the "2Ac . Main Condenser Cire. Waterbox. _ Unit 2 remained at a nominal 89% of rated thermal power through the end of this operating period.
Unit 2 occurrences during this operating period included.
On Friday, September 11, Reactor Engineering flux tilt testing successfully identified reactor control cell 38-07 as .the respective control cell containing degraced (leaking) fuel.
End-of-cycle control rod patterns were adjusted accordingly to minimize offgas radiation rates.
II. CHALLENGES TO MAIN STEAM SAFETY RELIEF VALVE 3 There were no challenges te the Main Steam Safety Relief Valves during the month.
uprtgex2
.. a. + w. n.,,, -- . . . - - - + ~ . - - .u.~
1 l&' l
- tm d u
(\ ,{4 e:
' t v
- O 1
- .N
, , "CN
" pq ' ,
l
- )
I
'I J
l -1 ~ 4>$ O6 kJ '
S- t i7 i N 8 >
l 'I I 4 1 2 M t W I e- 1 FL l '? T4 . 6 - J
$ 1 l &4 W 5 t- e i oi F zs - a ;
t i 4 4i at O4 kJ B % 9 i >= m 4 E
- i ( )Ui M W4 O^
I # 8 *a I- 7 i Ak INf 8 K i W O . b M ' bW.
d . uJ t e- @ @ E te n - e tw 4 g I I i P- 4 m 't i F 1 >Z CD C N c 4 M e O O N - e- m 8 t- i eUt .O e' X 4 J t Q O O O O- O O O'O O O O w a
..I H s sW i 'A F, uJ 6 w kJ . - e e e e- .- - e e 4 7 i N I .J l M 4 4 4 '4 i O 4 Ch 6W l > E OI Q%
i 6m6 4- G 6-- Eu O e =
8 6 e 44'I na H 2 N 4- W t t tH i [L Z uJ e.I O t 6 +t 1t 3'30 t t et I i (D 4 Q. t tW 6 5 4 M$Y i I J f U MM NQ kl
- Ifl e O M i uf I uJdMU F) I >
- 4 F1 i ** - uJ t #3 I J >+ uk H I 4
- h4 - - 8K ID 1 4t . (f Z u ^l
.1 > I 4 kJ tot J t ' .10 W uJ e6 uJ 6 Pt H &a : 2 14 en 2 e t
-J: Oio au! T at ss 3 H N I .> b to '@ O..
- N #1 4- M 4. P- Es On -. 0 04 . J t C 5 4 i V E ID J w 8 .4 e *- * ..N f4 - N . N N- (d N N . N.N O (E C
. ua + t. kJ > uJ O -H - V -Z- Z
! :O 2' 7 at O u .
g- .F--
. 3 - ato n 2-y a
' k . W O W ee ^n -
U 2 J'
> f () Mb ' kb 3' Q- H > +
_0 km !
.J J-.
M a
- 4. uA
> O ~Y r% n h3 d- L F-ul , O O tm b to e in e. O M . c) . ' cts . to to -. M o
- 4. r4 >Z m @ et N G f4 e e N *- N F) @ O 4 I. W: G t Jt O O- O O b (D Q:. (D CD (n Es CD S1 O O ' 6O u- #s n us e e e e e
'- > .e f *( ^$ -e~ 'e-
'4
. a ," Oh w
' ha 4 . un G: I C ,
2i et ui 1 E F i W CL t >_
25 t et M t E. .
- - >. e es M 4 e @ b cn a o e
-N q in . e
.2 4 e e e m.
v e ~ w O 'O.
O l-l' w <
+ y-~ - , - - - g , - 3 -c,.-- -- ,
- u. .r., .,._ 4 _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ . . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
s , , ..
OPERATING DATA REPCRT l
DOCKET M. 50 - 353 3921048250 DATE OCTOBER 8. 1992 ,
COMPLETED BV r*ILADE PHIA ELECTRIC COMPANY ,
MARL MECK REPORTS SUPERVISOR f BUSINESS UNIT LIMERICM GENERATING STATION TELEPHONE (215) 327-1203 EXTENSION 3320 l OPERATING STATUS - - - - - - - - _ - - - - - - - - - - - - - - - - - - - - - - - - . - - - -
l UNIT 2 l NOTES: TMERE WAS ONE LOAD I l 1 UNIT NAME: LIMERICK l
--__.-_--_ ----_--_----- -- ___--- l I REDUCTION TO 75% FOR l
- 2. REPORTING PERIOD: SEPTEVSER. 1E92 : [
- 3. LICENSED THERMAL POWER (f.%T; 3293 l FLUX TILT TESTING AND l
_-__--__-_------ l 4 NAMEPLATE RATING (GROSS MwE): 1138 TO LOCATE / REPAIR A TUBE l
.. _----_- ---- l 1055 i LEA *. IN THE MAIN CONDENSER l E. DESIGN ELECTRICAL DATING (NCT MwE): i i
- 6. MAAIMUM der 5NDABLE CAPACITV (GROSS Ma'E): 1C92 l CI.CULATING WATERBOK. l
! ---- ]
l l l 7 VAXIMU?t DEPENDABLE CAPACITv (NET MWE)- 1055 l l ------ --- ---------------..---------------------
l l b. IF CHANGES OCCUR IN CAPACITV RATINGS (ITEMS NUMBER 3 1HROUGH 7) SINCE LAST REPORT. GIVE REASONS:
- 9. POaER LEVEL TO WHICH RESTRICTED. IF ANy (NET MWE):
- 10. REASON 5 TOR RESTRICTIONS. IF ANv:
( THIS MONT:- VR-TO-DATE CLWUwATIVE
Hour 5 IN REPORTING PERIOD 720 E.575 24.647 12, NUMBER 05' HOURS REACTOP WAS CRITICAL 720.G 6.575.0 21.704.F 0.0 G.O O.0 j
- 13. REALTOR RESERVE SHUTDOWN HOURS ------------ ------------ ------------
720.0 6.575.0 21.145.4 14 HOURS GENERATOR ON-LINE -------- --- -----_------ ---------- -
0.0 0.0 0.0
- 15. UNIT RESERVE SHUTDOWN MOURS _------- --- .... . _---- .-------.--_
16 GROSS THERMAL ENERGY G'NERATED (MWH) 2.170.469 11.136.999 66.849.124
- 17. GROSS ELECTRICAL ENERGY GENERATED (MwH) 16.800 7.021.420 22.057.496 691,069 6.762,045 21.233.644
- 10. NET ELECTRICAL ENERGY GENERATED (MWH) ... -------- ------------ ---.....----
PAGL 1 OF 2
, ,