Text

g 3[/fk Note to:

G. Dick-Hazel Smith From:

'J. Gray

SUBJECT:

-GINNA OL AMENDMENT ON STAFF WORKING HOURS

^In a note to Hazel Smith' dated December 22, 1983, Joe Scinto indicated that he had two problems with the attached license amendment package

'concerning Staff working hours at Ginna.

Those problems were:

-(1). that the SER failed to adequately explain the changes to the amendment application-found necessary by the Staff and mutually agreed to by licensee; (2) - that the SER. failed to provide a basis for the.conclusory assertion that the 8/12/83. licensee letter that modified the amendment application was somehow encompassed within the Federal Register notice of the amendment issued on 9/21/83 The revised amendment package appears to take care of item (1) but does

-not adequately address i_ tem (2).

Althou'gh the 9/21/83 Federal Register notice was. published after the.

8/12/83 ' licensee letter modifying the amendment application, there is no mention in the notice of the 8/12/83 modification, no reference to the 8/12/83 letter, and no indication of any kind that the amendment under consideration.was that applied for in April 1983 as modified by the 8/12/83 supplemental application.

In view of this, the 9/21/83 Federal

- Register notice did not give proper and adequate notice to the public of

!the. amendment being considered.. Unless you can explain in the SER just how it-is that the public was apprised of the 8/12/83 amendment modification by the 9/21/83 Federal Register notice, that notice appears-insufficient to notify the' public of the actual amendment being

-considered. Absent such a demonstration in the SER, this license amendment needs to be renoticed so as~to fully and accurately describe the actual amendment we are considering.

[

G ay p-ADATOS4-166 PDR p

h 2