ML20105C263

From kanterella
Jump to navigation Jump to search
Provides Results of Review of NSHC Package Re Auxiliary Feedwater Initiation.Basis for Conclusion Insufficient
ML20105C263
Person / Time
Site: 05000000, Robinson
Issue date: 02/13/1984
From: Scinto J
NRC
To: Requa G
NRC
Shared Package
ML20102A920 List: ... further results
References
FOIA-84-166 NUDOCS 8502090358
Download: ML20105C263 (1)


Text

-.

n. ~..

.. ~.

)

~

February 13, 1984 Note to G. Requa

SUBJECT:

ROBINSON 2 - AUXILIARY FEEDWATER INITIATION (OELDf842135)

- This basis for the no significant hazarads _ consideration conclusion is not sufficient. All you simply say is that the reason for the changes is to make

- the tech spec consistent. That's dandy but there is no justification for asserting that the correct consistency is-to raise the 200* temperature to-350'.

Its not clear that the correct way to do this isn't to reduce the 350' to 200'..You have to give more description. Consistency is not sufficient.

You also have.to describe... not only is it consistent but.its the right way to be consistent. You have to have some discussion to indicate that this is the right direction for this change to be made in, that there isn't any problem with making the change in this direction..

C OA

..cc:

.M.

Karman 4

e i

,s I

s PDR

//cl W

-