CENTE:iOR ENERGY PERRY NUCLEAR POWER PLANT Mai Address:

PO. BOX 97 Robert A. Stratman 10 CENTER ROAD PE RRY, OHIO 44081 VICE PRESIDENT - NUCLEAR PERRY. OHIO 44081 (216) 259-3737 December 6, 1993 PT-CEI/1,CDU-0020 L Lake County Department of Utilities c/o Gary Long, Hentor Vaste Facility P.O. Box 490 Painesville, Ohio 44077-0490 I) ear Mr. Long, Enclosed are the Quarterly Self-Monitoring Reports for the Perry Nuclear Power Plant sanitary vaste system for the months of September, October and November 1993. All required samples were collected and analyzed in accordance with the self-monitoring program. .

Please contact Donna Tizzano at (216) 259-3737 extension 5514 if you have any questions.

Sincerely, fNf k d b)

RAS:DGT Enclosure cc: NRC Project Manager NRC Resident Inspector Office NRC Document Control Desk NRC Region III ,

100054 r]$

y.

Operchng Compon es Cleveland Dectnc tituminating l

10!e00 id$on 9312140086 931130 k, PDR ADOCK 05000440 e

[

R PDR m

, . . . . - - - . ~ - - - . ~ = . . . . - - .

l

. i l

INDUSTRIAL PRETREATMENT OUARTERLY SELF-MONITORING RESULTS  ;

Perry Nuclear Power Plant Permit No.: 1004911 10 Center Rd. Report Date: 9/24/93 l Perry, Ohio 44081 Laboratory: Vadsworth/ Alert Date of Sample: 9/2 to 9/3/93 Time of sample: 0915 Sample Location: Sewage Pump Station Name of Sampler: Greg Newman Laboratory Address: 1401 Shuffel Dr.

North Canton OH 44720 ,

i Date of Analysis: 9/3 to 9/16/93  !

Flow: 46,000 gpm Name of Analyst: Shery Fazio '

PARAMETER SAMPLE EPA ANALYSIS ANALYSIS -

TYPE METHOD DATE FESULT  :

C0D Composite 410.4 9/13 to 9/14 330 mg/L BOD Compcsite 405.1 9/3 to 9/8 140 mg/L 4 TSS Composite 160.2 9/8 240 mg/L

  • Silver Composite 200.7 9/7 to 9/12 None Detected pH Grab 150.1 9/3 8.3 s.u.

Oil / Grease Grab 413.1 9/15 to 9/16 8 mg/L i Gravimetric i I certify under penalty of law that I have personally examined and I am f familiar with the information in this report and that, based on my inqQiry  !

of those persons immediately responsible for obtaining the information. >

contained in this report, I'believe that the information is true, accurate, and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment. },

, [ke# $

  • Signatu'rs ' ' Dat6 Title l

.- . = _ - - -- - . _

_ = . -- -.

i_ .*

i I

~

INDUSTRIAL PRETREATMENT QUARTERLY SELF-HONITORING RESULTS 1 I

Perry Nuclear Power Plant Permit No.: 1004911 10 Center Rd. Report Date: 10/15/93 Perry, Ohio 44081 Laboratory: Vadsworth/ Alert .

Date of Sample: 9/30 to 10/1/93 Time of sample: 1000 Sample Location: Sevage Pump Station Name of Sampler: Greg Newman '

Laboratory Address: 1401 Shuffel Dr.

North Canton OH 44720 Date of Analysis: 10/1 to 10/15/93  !

Flow: 46,000 gpm Name of Analyst: L. Ezzo PARAMETER SAMPLE EPA ANALYSIS ANALYSIS I TYPE METHOD DATE RESULT '

C0D Composite 410.4 10/11/93 180 mg/L BOD Composite 405.1 10/1 to 10/6/93 180 mg/L TSS Composite 160.2 10/07 to 10/08/93 180 mg/L l i

Silver Composite 200.7 10/04 to 10/15/93 .014 mg/L i

pH Grab 150.1 10/1/93 8.8 s.u.

Oil / Grease Grab 413.1 10/12 to 10/13/93 16.0 mg/L '

Gravimetric '!

I certify under penalty of lav that I have personally examined and I am  !

familiar with the information in this report and that, based on my ingsiry  ;

of those persons immediately responsible for obtaining the information ,

contained in this report, I believe that the information is true, accurate, '

and complete. I am' aware that there are significant penalties for  !

submitting falso information including the possibility of fine and '

imprisonment.

pg - #Q_ , fP Vice President - Nuclear Sfgnatifre Date Title

. - - _ - ~ , . . _ - . - - . - -_- ..

INDUSTRIAL PRETREATHENT  !

00ARTERLY SELF-MONITORING RESULTS l k

Perry Nuclear Power Plant Permit No.: 1004911 10 Center Rd. Report Date: 93 Perry, Ohio 44081 Laboratory: Vadsworth/ Alert j Date of Sample: 11/4 to 11/5/93 Time of sample: 0915  ;

Sample Location: Sevage Pump Station Name of Sampler: Greg Newman  ;

Laboratory Address: 1401 Shuffel Dr.

North Caaton OH 44720 Date of Analysis: 11/5 to 11/18/93  !

Flow: 46,000 gpm Name of Analyst: S. Goodin

  • PARAMETER SAMPLE EPA ANALYSIS ANALYSIS TYPE METHOD DATE RESULT l

i C0D Composite 410.4 11/10 to 11/11/93 280 mg/L BOD Composite 405.1 11/5 to 11/10 230 mg/L  !

TSS Composite 160.2 11/10 to 11/11 280 mg/L Silver Composite 200.7 11/12 to 11/18/93 Hone Detected  ;

pH Grab 150.1 11/5/93 8.7 s.u.

Oil / Grease Grab 413.1 11/17 to 11/18/93 12 mg/L '

Gravimetric ,

I certify under penalty of law that I have personally examined and I am I familiar with the information in this report and that, based on my inq6iry of those persons immediately responsible for obtaining the information ,

l contained in this report, I believe that the information is true, accurate, i and_ complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.

If Vice President - Nuclear Sighaturs Date Title 1

-- - - .. . . . - -, . - -