2 ?m

<491 BALTIMORE -

GAS-ANDl ELECTRIC CHARLES CENTER . P. O. BOX 1475 + BALTIMORE, MARYLAND 21203

. GEORGE C. CREEL Vict PassiotNT Nvettan CNcMOT February 2g, 1990 (300 aeo-easa U. S. Nuclear Regulatory Commission Washington, DC-20555 ATTENTION: Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 Number of Personnel and Man-Rem by Work and Job Function - 1989 Gentlemen:

This ' report is submitted - for the Calvert - Cliffs Nuclear Power Plant (Facility Operating Licenses - DRP-53 and . DRP-69) . in -accordance. Technical Specification Section 6.9.1.5(a). ;The information. presented is for the calendar year 1989.

~ Should' you have any further questions regarding this matter, we will be plecsed to

' discuss - them with you.

Very truly -yours, s

GCC/ PSF /bjd Attachment -

' cc: D. A. Brune, Esquire -

J.' E. Silberg, Esquire

~ R. A.Capra, NRC D. G. Mcdonald, Jr., NRC W. T. Russell, NRC I J. E. Beall, NRC gr )DI(

T. Magette, DNR d y

-4A <h l

R1 A K f

7 - 1 1(;

ej j
  • BALTIMORE GAS AND ELECTRIC COMPANY i." O'4* ,CALVERT CLIFFS NUCLEAR POWER PLANT 1989-REPORT ON NUMBER OF PERSONNEL AND MAN REM BY WORK AND JOB FUNCTION [

No. OF, PERSONNEL (>100 MREM) TOTAL MAN

' STATION UTILITY CONTRACT STATION UTILITY CONTRACT-WORK & JOB FUNCTION EMPLOYEES EMPLOYEES WORKERS EMPLOYEES EMPLOYEES = WORKERS'

, REACTOR OPERATIONS & SURVEILLANCE

' MAINTENA.NCE PERSONNEL 2 0 2 .350 .000 .245 OPERATING PERSONNEL 25- 1 0 6.107 .126 .000 HEALTH PHYtlCS PERSONNEL 8 0 1 1.169 .000 .213 SUPERVISORY TERSONNEL 0 0 1 .000 .000 .281 ENGINEERlWG PERSONNEL 2 0 0 .256 .000 .000-ROUTINE MAINTENANCE MAINTENANCE PERSONNEL 12 1 12 3.651 .238- 2.574 OPERATING PERSONNEL 0 0 0 .000 .000 .000 HEALTH PHYSICS PERSONNEL 0 0 3 .000 .000 .691

' SUPERVISORY PERSONNEL ~ 0 0 0 .000 .000 .000 ENGIMERING PERSONNEL 0 0 1 .000 .000 .107 INSERVICE INSPECil0N MAINTENANCE PERSONNEL 5 10 64 .923 3.488 23.323 OPERATING PERSONNEL . 1 0 1 .111 .000 .330 HEALTH PHYSICS PERSONNEL 3 0 32 .610 .000 7.128 SUPERVISORY PERSONNEL 0 0 1 .000 .000 .455 'i ENGINEERING PERSONNEL 7 1 5 3.230 .158 1.200 SPECIAL MAINTENANCE i' MAINTENANCE PERSONNEL 95 39 199 30.238 14.927 74.787 OPERATING PERSONNEL 8 0 1 1.040 .000 .218 HEALTH PHYSICS PERSONNEL 12 0 68 4.816 .000 20.941 SUPERVISORY PERSONNEL 6 0 21 1.791 .000 6.900 ENGINEERING PERSONNEL 9 0 14 1.765 .000- 3.312 1

if WASTE PROCES$!NG l MAINTENANCE PERSONNEL 1 13 22 .104 5.667 6.333 OPERATING PERSONNEL 0 0 1 .000~ .000 .337 HEALTH PHYSICS PERSONNEL 20 1 17 6.874 .694- .4.449 l

SUPERVISORY PERSONNEL 2 0 1 .582 .000 .416 .

ENGINEERING PERSONNEL 0 .0 0 .000 .000 .000- -i REFUELING l MAINTENANCE PERSONNEL 25 5 21 10.552 .801 4.283 OPERATING PERSONNEL 1 0 4 .603 .000 .454 l HEALTH PHYSICS PERSONNEL 11 1 61 2.808 .288 17.053 SUPERVISORY PERSONNEL 4- 0 0 1.876 .000 .000 ENGINEERING PERSONNEL 1 0 1 .107- .000 .228 TOTAL (SUM OF 6 WORK FUNCTIONS > 100 MREM)

MAINTENANCE PERSONNEL 134 62 288 55.369 27.103 122.029 OPERATING PERSONNEL 40 1 12 10.469 .200 2.261 j HEALTH PHYSICS PERSONNEL 36 1 116 18.601 1.114 58.406 i' SUPERVISORY PERSONNEL 11 1 24 5.004' .100 8.465 ENGINEERING PERSONNEL 23 1 19 7.328 .210 5.355  !

L GRAND TOTAL 244 66 459-  %.771 28.727 196.516 _;

TOTAL MAN REM OF ALL WORKER $*- 106.151 30.617 209.532

-l

  • TOTALS INCLUDES EXPOSURE OF IN0lVIDUALS WITH LESS THAN 100 MREM.

L