Semi-Annual Surface Water Withdrawal Rept
ML20195J767
Person / Time
Site: Calvert Cliffs  
Issue date: 12/31/1998
From: Crinigan P
BALTIMORE GAS & ELECTRIC CO.
To:
Shared Package
ML20195J657 List:
References
NUDOCS 9811250061
Download: ML20195J767 (39)


Text

,

l l

I ATTACHMENT (9) ENCLOSURE (H) l I

i i

l l

l l

l l'

i I

SEMI-ANNUAL SURFACE WATER WITHDRAWAL REPORT 1987 - 1998 SUBMITTED BY f

BALTIMORE GAS AND ELECTRIC COMPANY TO l

MARYLAND DEPARTMENT OF NATURAL RESOURCES WATER RESOURCES ADMINISTRATION I

l l

l l

9811250061 981120 PDR ADOCK 05000317 l

P PDR j

Baltimore Gas and Electric Company 1-Calvert Cliffs Nuclear Power Plant November 20,1998 l

i

@,l v c s%wN. u o.

ss:.erav JAugs w. pccx J3HN R. CRIFFIN

... sero.

l c:ever sec.sta.,

STATE OF MARYLAND.

i DEPARTMENT OF NATURAL RESOURCES

' WATER RESOURCES ADMINISTRATION l

i

!2ERMIT CA7IS001 TAWES STATE OFFICE BUILDING ANNAPOllS, MARYLAND 21401 MAKE NAME/A00RESS CHANGES BELCW BALTIMORE GAS & ELECTRIC ATTN:

P.

T.

CRINIGAN CALVERT CLIFFS LUSBY, MD 20657 i

1 i

1 EAR' PERMITTEE:

~~~~

~

\\

AS A CONDITION CF YOUR MARYLANC WATER APPROPRIATION AND USE PERMIT YOU j

l t EQUIRED TO REPORT YOUR WATER WITFDRAWAL EVERY SIX MONTHS.

OCPPLETE AhD RETUPN

'HIS FORM TO SATISFY THISj REQUIREFENT.

IF YOU HAVE QUESTICNS CONCERNING TEIS

'ORd, PLEASE TELEPHONE THIE WATER SUPDLY DIVISION AT (301) 974-3675.

198 7 SEMI-ANNUA L W ATER WITHDRAWAL REPORT 1.

CHECK THE~ METHOD USED TC CETERMINE YOUR aITHDRAWal AMCLNTS:

( ) FLOW PETER

( ) ELAPSE 3 TIME INDICATCR

( X) C TH E R (EXFLAIN)

Hourly computer printout with daily average 2.

ENTER THE NUMBER OF GALLONS OF WATER JITHDRAWN FOR EACH MONTH.

IF YOU HAVE MULTIPLE. INTAKES UNDER THIS. PERMIT, PLEASE ADD TOGETHER THE MONTHLY TCTALS FOR ALL INTAKES.

- 00 NOT LIST CONTINUOUS METER READINGS, HOURS PUMPEC, OR GALLONS IN PGO.

JANUARY 19 8 7.....

8. 92..E+10.....

APRIL 19 8 7...... 5 17..E.+.10............

FEBRUARY 1987......!*,09.!!{0.....

MAY 1987......bSI..Edg,,,,,,,,,,,

MARCH 19 8 7...... $ *.8,9, g;1,0.....

JUNE 19 8 7...... h04, EdO,,,,,,,,,,,

TOTAL......%29. Egg,,,,,,,,,,,,,,,,,,,,

3.

PLEASE SIGN AN DATE THIS FORM.

SUBMITTED BY...!

. h...

DATE....

O TI TLE..G.ene.ral Supervisor - Chemistry l

4.

MAKE ADDRESS CORRECTIONS CN THE TOP OF THIS FORM.

PLEASE CONTACT THIS OFFICE IF OWNERSHIP HAS CHANGE 0.

5.

RETdRR THIS FORM IN THE ENCLOSED ENVELOPE (POSTAGE REQUIR ED).

s e

)

c'R%OY C. CGCWN. M.S.

JAMES W. PECK

.sKcta.T passt..

JOHN R. GRIFFIN

- - * ^

--r--

~

.sputy.sc.sta.T STATE OF MARYLAND DEPARTMENT OF NATURAL RESOURCES WATER RESOURCES ADMINISTRATION TAWES STATE OFFICE BUILDING ANNAPOLIS, MARYLAND 21401 l

PERMIT CA71S001 MAKE NAME/ ADDRESS CH ANGES BELOW BALTIMORE GAS & ELECTRIC ATTfJ:

P.

T. CRINIGAN CALVERT CLIFFS LUSBY, MD 20657 DEAR PERMITTEE:

AS A CONDITION OF YOUP MARYLAND WATER APPROPRIATION AND USE PERMIT YOU ARL REQUIS.ED TO REPORT YOUR WATER WITHDRAWAL EVERY SIX MONTHS.

COMPLETE AND RETT THIS FORM NO LATER THAN JANUARY 31, 1983. IF YOU HAVE QUESTI0f4S CONCERNING Ti FORM, PLE ASE TELEPHONE THE WATER SUPPLY DIVISION AT (301) 974-3675.

1987 SEMI-ANNUAL WATER WITHDRAWAL REPbRT 1

CHECK THE METHDD USED TO DETE9MINE YOUR WITHDRAWAL AMOUNTS:

(' 3 FLOW METER

( ) ELAPSED TIME INDICATOR

( X) D THF.R (EXPLAIN)

Hourly computer printout with daily average 2.

ENTER THE NUMBER OF GALLONS OF WATER WITHDRAWN FOR EACH MONTH.

IF YOU HAVE MULTIPLE INTAKES UNDER THIS PERMIT, PLEASE ADD TOGETHER THE MONTHLY TOT ALS FOR ALL INTAKES.

- DO NOT LIST CONTINUOUS METER READINGS, HOURS PUMPED, OR GALLONS IN MGD.

19 87.....,630,400,000 104 1987.. 92,478,800,000 OCTOBER

' JULY 1987. 100,807,100,000 AUGUST 1 987. 100,080,500,000....

NOVEMBER 19 87.....,035,100,000 107 1987. 103,678,900,000 DECEMBER SEPTEMBER-608,710,800,000 TOTAL.................................

3.

PLEASE SIGN Af ATE THI FORM.

( m...

D AT E.../8/88 1

SUB.HI'TTEDBY./

TITLE. General Supervisor - Chemistry i

l 4.

MAKE ADDRESS CORRECTIONS Old THE TOP OF IHIS FORM.

'PLEASE CONTACT THIS OFFICE IF OWNERSHIP HAS CHANGED.

~5.

. RETURN THIS FORM IN THE ENCLOSED ENVELOPE (POSTAGE REQUIFED).

TCIEY C. BROWN. M D.

.tc.tra.v JAMES W PECM

..ascio.

JMN R. GRIFFtN

.s.wiv..c.sta.?

STATE OF MARYLAND DEPARTMENT OF NATURAL RESOURCES WATER RESOURCES ADMINISTRATION i

TAWES STATE OFFICE BUILDING ANNAPOLIS, MARYLAND 21401 PERMIT OA71S001 MAKE NAME/ ADDRESS CHANGES BELOW BALTIMORE GAS & ELECTRIC ATTN:

P.

T.

CRINIGAN 1

CALVERT CLIFFE LUSBY, MD 20657

)

DEAR PERMITTEE:

AS A CCNDITION OF YOUR MAPYLANO WATER AFP;0PPIATION AND JSC PERMIT YOU ARE REQUIsED TO REPORT YOUR WATER WITHDRfWAL EVERY SIX MONTHS.

COMPLETE AND RETURN

-THIS 50RM NO L A T E R T N t.N JUL Y 31,15 f4. IF YOU HAVE CUESTIONS CONCLRNING THIS FORM, PLE;EE TELEPHONE THE WATER SUPPLY DIVISION AT (301) 974-3675.

1909 SEMI-ANNUAL W A TER WITHE RA WA L REPORT I.

O w E C t( THE HETnCD USED TO DETERMINE Y3UR WITHERAWAL AMOUNTS:

1

( ) FLOW METER

( ) ELAPSE 0 TIME INDI; ATOP (X)3THER (EXPLAIN)

Hourly computer printout with daily average 2.

ENTEb THE NUMPER OF GALLONS OF WATER WITHDRAWN FOR EACH MONTH.

IF YOU HAVE MULTIPLE INTA<ES UNDER THIS PEPMIT, DLEASE ADD TOGETHER THE Mot 1THLY TOTALS FDP ALL INTAKES.

- 00 f40T LIST CD?.TINUOUS METER READINGS, HOURS PUM ED, OP GALLONS IN MGD.

JANUARY 1 986... 106.,.429,600.,000...

APRIL 19 8 8... 6 7. '.193 200.'.000..........

J F E B R U A:. Y 19 e e.... N'.04p,2,g,,T...

MAY 19 8 6.... p3,,,6,3,0, y,,,000,,,,,,,,,

M A r..

4 1968... 55.,.680,050.,000...

1 9 8 8... 6 2. '.3 9 7 98 6.'.000.......... ~

JUNE J

440, 377,036.,000.................

TOTAL 3.

PLEASE SIGN AN D TE THIC F AM.

I....

D t T E. 6,/,g8,,,,,,

SUBMITTED B Yj...

T I T L E....IE*.#.8.. hP,e,r,vgo,,

,Ch,e, mis t ry s.

4.

MAKE ADDRESS CORRECTIONS ON THE TOP OF THIS FORM.

PLEASE CONTACT THIS OFFICE IF OWNERSHIF Nf.S CHANGED.

t j

5.

RETUDN THIS FORM IN THE ENCLOSED EfVELOPE (POSTAGE REQUIRED).

l

u..

~

NIQIc Miryl nd Dep:rtment of Ndural Resources I:'.d1hE.;. w......

Water Resources Administration

'lPCTE g Donald Schaefer Tawes State Office Building Annapolis, Maryland 21401 Torrey C. Ban, M.D.

~

'DNR TTY for Deaf: 301 974 3683 Catherine P. Stevenson

. Dinctor l

PERMIT CA71S001 MAKE.NAME/ ADDRESS CHANGES BELOW B ALTIMORE GAS & ELECTRIC -

ATTN:

P.

T. CRINIGAN CALVERT CLIFFS LUSBY, MD 20657 l

DEAR' PERMITTEE:

l AS A CONDITION OF YOUR MARYLAN': WATER APPROPRIATION AND USE PERMIT YOU ARE REQUIRED TO REPORT YOUR WATER WITHDRAWAL EVERY SIX' MONTHS.. COMPLETE AND RETUR THIS FORM NO L ATER TH AN J ANU ARY 31',

1989.

IF.YOU HAVE ANY QUESTIONS CONCERNIh THIS FORM, PLEASE TELEPHONE THE WATER RIGHTS DIVISION AT (301) 974-3675.

l 1988 SEMI-ANNUAL WATER WITHDRAWAL REPORT l

1.

CHECK THE METHD,3 USED TO DETERMINE YOUR WITHDRAWAL AMOUNTS:

l

( ) FLOW METER

( ) ELAPSED TIME INDICATOR

( X) 0 THE R (EXPLAIN) Hourly computer printout with daily average j

l 2.

ENTER THE NUMBER OF GALLONS OF WATER WITHDRAWN FOR EACH MONTH.

IF YOU HAVE MULTIPLE INTAKES UNDER THIS PERMIT, PLEASE ADD TOGETHER THE MONTHLY TOTALS FOR ALL INTAKES.

DO NOT LIST CONTINUOUS METER READINGS, HOURS PUMPED, OR GALLONS IN MGD.

19 8 8..1,0p g,6,0 pgo,,0p9...

OCTOBER 1988.....'I82,1,,0gg,,0,00,,,,,,,,,,

3 j

JULY 19 8 8..106. L.31 700.,.000....

NOVEMBER 1988... 94,468,400.,.000 0

J AU, GUST 19 8 8...I.0,7 2 6,0,,0gg,,0,0,0,,,,,,,,,,

S EPTEMBER ~ 198 8..1p2 9,1,7 ?gg,,0p9...

DECEMBER 2

g f

TOTAL..6,1gs,9,,299,,00p,,,,,,,,,,,,,,,,,,

l 3.

PLEASE SIGN AN ATE THIS ORM.

M...... D A T E..I./ p(8,9,,,,,,,,,,,,,

SUBMITTED.BY

. T I T L E ff.":.sqp,e,ryi,s,oy,,,C,hemht,r7 T E L E P H O N E N U M B E R. 2,6h47,2,9,,,,,,,,,,,

MAKE' ADDRESS CORRECTIONS ON THE TOP OF THIS FORM.

4.

PLEASE CONTACT THIS OFFICE IF OWNERSHIP HAS CHANGED.

5.

RETURN THIS FORM IN THE ENCLOSED ENVELOPE (POSTAGE REQUIRED).

1

a_

Mrryhnd Dep:rtment of Natural Ressurces

~- ~

1 4U.WWiWilliam Donald Schae5 Water Resources Administration

~u Tawes State Offlec Building

' ' '

  • V *"

Annapolis, Maryland 21401

Torrey C. Brown. M D.

'~

DNR TTY for Deaf:'301974-3683

' Catherine P. Stevenson Disctor i

PERMIT CA71S001 MAKE NAME/ ADDRESS CHA.NGES BELOW BALT1HORE GAS & ELECTRIC -

l ATTN:

P.

T. CRINIGAN CALVERT CLIFFS LUSBY, MD '20657 DEAR PERMITTEE:

AS A CONDITION OF YOUR MARYLAND WATER APPROPRIATION AND USE PERMIT YOU ARE REQUIRED TO REPORT YOUR WATER WITHDRAWAL EVERY SIX MONTHS.

COMPLETE AND RETUR THIS FORM NO LATER THAN JULY 31, 1989.

IF YOU HAVE ANY QUESTIONS CONCERNING THIS FORM, PLEASE, TELEPHONE THE WATER RIGHTS 01 VISION AT (301) 9T4-3675.

1989 SEMI-ANNUAL WATER WITHDRAWAL REPORT 1.

CHECK THE METHOD USED TO DETERMINE YOUR WITHDRAWAL AMOUNTS:

( ) FLOW M ET E R

( ) ELAPSED TIME INDICATOR (X)0THER (EXPLAIN) liourly computer printout with daily average 2.

ENTER THE NUMBER OF GALLONS OF WATER WITHDRAWN FOR EACH MONTH.

IF YOU' HAVE. MULTIPLE INT AKES UNDER THIS PERMIT, PLE ASE ADD TOGETHER THE MONTHLY TOTALS FOR ALL INTAKES.

- DO NOT LIST CONTINUOUS METER READINGS, HOURS PUMPED, OR GALLONS IN HGD.

106 19 8 9.. 50 23 9.,.200.'.000...........

1989.....,239,300,000 APRIL 4

JANUARY 96 FEBRUARY

-1989....,309.100,000 MAY 19 8 9.. 3 5 3 61.,.200.'.000..........,

4 19 8 9....,....,600,'0'00 43 111 19 8 9.. 29 427 300.'.000...........

.1

/

JUNE MARCH 360,687,700,000 TOTAL..................................

3.

PLEASE SIGN AND DATE THIS FORM.-

D A T E. 7./.9./.8 9............

SUBMITTED BY............................

l l

T I TL'E.......pervisor - Chemistry................ TELEPHONE NUMBER. 260..4729............

Gen. Su l

l i

4.

MAKE ADDRESS CORRECTIONS ON THE TOP OF THIS FORM.

I PLEASE CONT ACT THIS OFFICE IF OWNERSHIP HAS CH ANGED.

i i

5.

RETURN THIS FORM IN THE ENCLOSED ENVELOPE (POSTAGE REGUIRED).

s

K. T..

b.

,g.r,m NTry1$lidDepartment of Naturill Res0NrI8 2.

y

"?

4 Water Resources Administ' ration ' ~

?MQQ$%* $ WITS 6 Donald schdrer E

,1.,.:;;;- W" ~ ~ '

Tawes State Office Building

.. n :P y y /,3 r Dro m a~

r

_ Annapolis, Maryland 21401

~

'"T^~~~'

~~

,DNR TrY for Deaf: 301 974-3683

' Catherine P. Sinenson

' Director PERMIT CA71S001 MAKE NAME/AODRESS CHANGES BELOW CALVERT CLIFFS NUCLEAR PLANT

. ATTN:

P. T. CRINIGAN LUSBY, MD 20657 O

DEAR PERMITTEE:

AS A CONDITION OF YOUR MARYLAND WATER APPROPRIATION AND USE PERMIT YO REQUIRED TO REPORT YOUR WATER WITHDRAWAL EVERY.SIX MONTHS.

COMPLETE AND RETURN THIS FORM NO LATER THAN JANUAR'Y 31, 1989.

IF'YOU H' AVE ANY QUESTIONS CONCERNING THIS FORM, PLEASE TELEPHONE THE WATER RIGHTS DIVISION AT (301) 974-3675.

1989 SEMI-ANNUAL'WkTER' WITHDRAWAL R'EPORT

~

)

CHECK THE METHOD USED TO DETERMINE YOUR WITHDRAWAL AMOUNTS:

1.

( ) FLOW METER

( ) ELAPSED TIME INDICATOR (X)DTHER (EXPLAIN)

Hourly computer printout with daily average ENTER THE NUMBER' 0F GALLONS OF WATER WITHDRAWN FOR EACH MONTH.

2.

IF YOU HAVE MULTIPLE INT AKES UNDER THIS PERMIT, PLEASE ADD

~

.TOGETHER THE MONTHLY TOTALS FOR ALL INTAKES.

- DO NOT LIST CONTINUOUS METER RE ADINGS, ' HOURS PUMPED, OR GALLONS IN MGD.

19 8 9.14.,.618.,500.,000.............

19 89. 5.,.639.,800.,000......

OCTOBER JULY 19 8 9.18.,.7 70.,500,000.............

AUGUST 19 8 9. 4.,.23 8.,500.,000......

NOVEMBER 1989.27.,.576.,200.,000 SEPTEMBER 1989.20.,.258.,300.,000 DECEMBER T O T A L. 91.,.101, 8 00,000...................

3.'

PLEASE SIGN AND TE THIS ORM.

7....... D m. 1./.5/ 90 SUBHI m D BY TI TLE. Gen. Supervisor - Chemistry TELEPHONE NUMBER.301-260 4729 4

MAKE ADDRESS CORRECTIONS ON THE TOP OF THIS FORM.

PLEASE CONT ACT THIS OFFICE IF OWNERSHIP HAS CHANGED.

\\

5.

. RETURN THIS FORM IN THE ENCLOSED ENVELOPE (POSTAGE REQUIRED).

w.._

, r.... m.<w.

+ = y z. n ; i.;

7.m M G,U C W y % in n.T,

..z-

\\

N A

7

Mcifylaind Dep;rtment ef Nitural'REsofi~ reds' ~3M35$735E....a.!.3 MfMT[~~Nd!!ad Don'ald Sch WaTefResources Administration - A'

.$5 M M kD NJ@M.T E

Tawss State Office Building '

~

W.?"WiwiND%y seer,wy.' Brown i

> :.mtJ. YokC H.

(Annapolis, Maryland 21401

~'

J DNR TTY for Deaf: 301 974 3683

u.. J..

'u

~

u--

j.-

i :. Catherine P. Stevenson ohutor A

PERMIT CA71S001' i

MAKE.NAME/ ADDRESS CHANGES.BELOW BALTIMORE GAS & ELECTRIC

' ATTN:-P.

T'.

CRINIGAN' CALVERT CLIFFS LUSBY,.MD 20657 DEAR PERMITTEE:

AS A CONDITIOff 0F YOUR M ARYL AND W!.TER APPROPRI ATION AND USE. PERMIT YOU ARE REQUIRED TO REPORT YOUR WATER WITHDRAWAL EVERY SIX HONTHS.

COMPLETE AND RETUF

.THIS FORM NO L ATER THAN JULY.' 31,~1990. 'IF YOU HAVE ANY QUESTIONS CONCERNING THIS FORM, PLEASE. TELEPHONE THE WATEC. RIGHTS DIVISION AT.(301) 9.7.4-3675.

1990 SEMI-ANNUAL WATER WITHDRAWAL REPORT 1.

CHECK THE METHOD USED'TO DETEP. HINE YOUR WITHDRAWAL AHOUNTS:

( ) FLOW METER

( ) ELAPSED TIME IfJDICATOR

( X) OTHE R (EXPL AIN ) Hourly computer printout with daily average i

l 2.

ENTER THE NUMBER OF GALLONS OF WATER WITHDRAWN FOR EACH MONTH.

IF YOU.HAVE HULTIPLE INT AKES UNDER THIS PERMIT,.PLEASE ADD TOGETHER THE MONTHLY TOTALS FOR ALL INT AKES.

DO NOT LIST CONTINUOUS METER READINGS, HOURS PUMPED, OR GALLONS IN MGD.

JANUARY 19 9 0... 2,6,,g g,,0,0pgy,0...

APRIL 19 9 0... N'.0,3 8 @/ 9M..........

3 19 9 0... 2,4 g2,,4ppgg,0...

MAY 19 9 0.. 19.'.9.9 8.0,0, pM,,,,,,,,,,

3 F E'B RU AR Y j

'HARCH 19 9 0... 38,,g3,,9pp g,0,0...

JUNE 19 9 0...E'.5,6? g@,0, gg,,,,,,,,,,

o

... 182.,.151.,.700.&.00.................

0 TOTAL 4

.3.

PLEASE SIGN Af' DATE THI FORM.

~

~

'.Mg.$........

- Dm..iwm...........

SuBHI m 0 T I T L E. Gen. ' S.upe.r.v.is.o.r...C.h.e.m.is. t.r.y T EL E P H O N E N U M B E R.301..260..4729.........

j 4.

LHLKE ADDRESS CORRECTIONS ON THE TOP OF THIS'FO'RM N "^

PLEASE CONTACT THIS'0FFICE IF OWNERSHIP HAS CHANGED.

. =..

1 i

5. ' RETURN THIS FORM IN THE ENCLOSED ENVELOPE ~(POSTAGE REQUIRED).

?;'.h..

...-.-. n.......

.v:. ' =. ::...y.

.o.

y o.

  1. ie sMarylrd Dep:rtment cf N:tural Rei6EEdes C;.N. ~ @i%h"

_y g

4WW J125"Ndliam Donald schaerer

~~~

4M%%M;hm Wcter.Reso rces Administratia

[.

jAnnapolli, Maryland 21401

' N$yQf{9g.j y'[Mh[N FN~

yd4 Jaw &Stite Offlec Building'. '

~

,gy C. B

~ $ [ "'.".E'E N5D N~'

"L.a _, s,

<rt.

DNR TTY for Deaf: 301 974-3683

?? M Citheiine P. Stevenson

.. x...u....

-.5.:.. p,

t PERMIT.CA71S001

~

MAKE N?.ME/ ADDRESS CHANGES BELOW BALTIMORE GAS & ELECTRIC ATTN:

P.

T. CRINIGAN CALVERT CLIFFS LUSBY, MD 20657 DEAR PERMITTEE:

AS A CONDITION OF, YOUR MARYLAND WATER APPROPRIATION AND USE PERMIT.YOU ARE REQUIRED TO REPOC.T YOUR W;.TER WITHDRAWAL E VERY SIX ' MONTHS.. COMPLETE AND RETUF THIS FORM'NO LATER THAN JANUARY 31, 1991.

IF.YOU HAVE ANY 00ESTIONS CONCERNI.\\

THIS FORM, PLEASE TELEPHONE THE WATER RIGHTS DIVISION AT (301) 974-3675.

j 199 0 SEMI-ANNUAL W ATER' W ITHDR AW AL REPORT

~

1 CHECK THE METHOD USED TO DETERMINE YOUR WITHDRAWAL AMOUNTS:

-t

) FLOW METER

( ) ELAPSED TIME INDICATOR

( X) OTHE R (EXPLAIN) Hourly computer printout with daily average

'2.

ENTER THE. NUMPER OF GALLONS 0F WATER WITHDRAWN FOR CACb H0t1TH.

IF YOU HAVE' MULTIPLE INTAKES UNDER THIS FERMIT, PLEASE A00 TOGETHER THE MONTHLY TOTALS FOR ALL INTAKES.

00 NOT LIST CCNTINUOUS METER READ'INGS, HOURS PUMPE0, OR

' GALLONS IN MGO.

1 9 9 0.....,...,...., 000...........

51 813 500 1990.....,174,900,000 OCTOBER 26 JULY 51 294 500 19 9 0.....,...,...,000 1990.....,365,500,000 NOVEMBER -

21 AUGUST 19 9 0.. 45,96 6.,.100.,000...........

'2 SEPTEMBER 1990.....,870,000,000 DECEMBER 3

~

229,484,500,000 TOTAL.................................

3.

PLEASE SIGN AND THIS RM.

DATE...N.'.I............

S.u B M I T T ED :B Y....

..~.....

TI Ti.E.. Gen. Sup'ervisor - ChemistryT EL EP HON E NU F B ER. 301-260.-4729........

l 4.

MAKE' ADDRESS CORSECTIONS OH THE TOP OF'THIS FORM.

PL E ASE CO'4T ACT THIS OF FICE Ir OWNERSHIP HAS. CHANGED.

5.

RE TURN THIS FORM IN THE ENCLOSEO ENVELOPE (POSTAGE REQUIRED).

g g

a 4

?---

..,.r...._

M:ryland Deprrim:nt cf Nr.tural Res:;urces

.W Tawes State Office Building Water Resources Addinistration William Donald Schaefer U""'

Annapolls. Maryland 21401 Torrey C. Brown. M.D.

I DNR TTY for Deaf: 301-974-3683 Catherine P. Stevenson Dinctor P ERM:T C A71So:1 FAKE is4*1E/ADDRE35 CHANGE! BELCW B;LT!PC.RE GA3 & ELECTRIC A T T *. :

F.

T.

C A I's I G A t4 C'.LVEFT CLIFFS LUS"Y, t'. ")

FC57 1

s.

4 D E1.9 ;~L": TT E:

f 4

.'. S A :. 'j] ; T *.. ' !F Y.2. U ; **; ; Y L .

4 A T C'.

C

P *.'. T *. ':

. ; '.; U E F E r t/ ; T YOU :: -_

P. f i.d U. dTI T3 s i. T.' : T Y~'G d *. T r' L vIT**RJ.u-L ** V E P Y 5X l' ? IsTML.

C i4 L E T E 2, ', D f. [ T, "

)

Teil s ~ A ' F: L;T E T-;1 dblY 31, 1901.

!~ YOU 4:.VE I.,' Y ;iU E;T I C:;5 C 0!J C E ; ?. l id-

- T H I S ; - ~. ". ' L ~ ; ;. T E L E ; r-M. r. TM-W: TE: R I r,4 T S O ! V : 0 :." AT ( 3.' ; ) 074-267:..

10?! S E " ! - 1. 'J '4 U ?. L

.!

  • T E: WIT *t;; ;i. AL R EF.0 T 3

1 C-iCK TH: t ' " T u !' USEP TO :ETER"IlE Y O L F.

t: T w] :. ; a !. L aMOUNTE:

(

):"L.,

. 7.;' p

(

) ? L O 0 7. r..

    • y.*

.v a.u,,. e *s - i

  • r, i...

( Xy T-

-e

( Xr

. t.-) Hourly computer printout with daily average h t s,-

..- or u - L L. f.,.-

.c r a

d..

..T...a-w. r s; m _ -cr i,r

,.,t W.

'F Y.'J e:VE 'eULT.' LE T f K EC UN EF Tb!C F E T.F ' T,

's L E ;,, E ; *..'

??GiTHE3 T r C **Ofj TML Y T'TtLE "C5

LL IUT:.K'5

~

'.n c'T L : 5-T C ?'J T :MU :U! t'ET EF. FEa0!hGO, HOU;S EU";EC, CP G :. L L )'!: ;N USD.

53,232.000.000 71,172 3qv.1........,000.000

- J U.., Y n,..................

.o.

2 81,707 19 51........,000,000 F ;. P.U. : Y

c 21.. N o.6 N a N #9 N....

"AY 70.826,000,000 55,930,000 000

"'4CH

";'1..................

J U'; E 1291...........,..............

382,535,000,000

,.Tal

,5.

PLE;5r 1 : t t. ; '. D ' - - THI"!

F 0 F 5'.

..n.......

./.......

.../...........

.s 2

ny.

. Gen. Supervisor - Chemistry 301-260-4729 3

7. T L -:....................... T. L ' H t ' ': :. r v '1 E :....................

s.

c.

'-<- ;rY E!: CCi iCTIC'.C ' " i' T*; 0F T":: FC r r.
t. /. S C. '. T ;. C T T *- ! S '.' F F I C E

~F

.W'lEECw!P.3 C s i'.G r 9.

T

-1.

. TU T-: 2 FS" I ),

T r :. i.. C L. E E.' # '. V I. L

  • L -

(r;;T;..

f G' : DC: ).

w.c;xmm
....;
m

...,, s??,. ~ ~, '. >...

^

_.c.

M dys Maryland Departm:ct cf N:tural Reso.. h?.3.?D_i, al.h

.$.l.. C,7 *. f.

3.. 5i lJ m... ;

+.

g _..

.a..

rces M 's.: m.w.c. -l

m. _,

It WateFRes' urces Adadalstration " (*($g@%Qf((jgNaldgg.n o

  • ah.e - 3 Tawes State Office Building P'~rk r

[

. Annapolis, Maryland 21401 -

9 M.r < ?qy.gTorrey C. Brown. M.Il M' '..

W* ~ ~ k)NR TTY for Deaf: 301 974-3683-+v E E-97 M Sw u. --

C

+ Cathenne P. Stevenson a

+maroe OM

$l l$ e DMe.A'l%

l PERMIT CA71S00.1 H AKE -NAME/ ADDRESS CH ANGES BELOW BALTIMORE ~ GAS & ELECTRIC ATTri:

P.

T. CRINIG Af4 CALVERT CLIFFS LUSBY, MD 20657 l

l e

.D E AR ER9? TTEE:

AS' A CC NDI TION.0F Y OUT; M'RYLANg WATER APPP.CPFI ATION. AND USE PERMIT 'YOU ARE

.R EG'UIREC T O RED 0b T YCUR We TCP. WITh0R AWAL EVERY SIX HONTHE. ' COMPLETE AND RETUR?

T HIS 'POR'4 f.*0 LATER ThAN JANUARY 31, 1992.

IF'YOU HAVE.ANY QUESTIONS CONCERNINC THIS FOR*4. PLEASE TELEPHDNE THE WATEF _ RIGHTS DIVISION Ai (301) 974-3675.

19c1 S C ". I - A N N U A'L WATED WITHDRAW AL REPORT 1.

CHECK Thi VLTHOD USED TO DETEPHINE YOUR WITHDRAWAL AMOUNTS:

( ) FLOW METER

( ) EL ACSED TIME INDIC A T0n

( 3?THCR (E XPL A IN) Hourly computer printout with daily average

.2 E';TER T H E ' NU d.E ER OF G ALLONS OF W A T ER WITHORAWN FOR EACH MONTH.

i

~ IF YOU HAVE MULTIPLE INT AKES UNDEF THIS PERMIT, PLEASE ADD 1

TOGETHER THE MONTHLY TOT ALS FOR ALL INTAKES.

i 00'NOT t.IST CONTINUOUS HETER RE ADINGS, HOURS PUMPED, OR GALLONS IN HGO.

~.1991. ??3.00 pgo,,,099.....

OCTOBER 19 91.Y/ Ms.Oppg qq0,,,,,,,,,,,,,

1 l

. DULY

/

. AUGUST.

1991. h9h'.8,9,6;g,,,099....

NOVEM BER. 1991.70 960,,0 ppa 000,,,,,,,,,,,,,

/

XS tP TE ne t R 1991. !?3 o.5,6,990,,ogg,,,,

ggcggggg - 3 9 91,9,7, $,,0pp, @,0,,,,,,,,,,,,,

..N!'.0,6,3,gq0,0pg,,,,,,,,,,,,,,,,,,

TOTAL j

, 3.

PLE ASE SIGN' AN TE THIS F RM.

SU BNI T T'E D'

../

f3T'......

D A T E. N.2yg,,,,,,,,,,,

' T I T L E. ?*'l*.ra},s,up,e,ryi,sp,r, ;,9,ef s tf?L E P HO N E f U H B E8. M"'.2pp7 t.2,9,,,,,,,,

t7

~

4.

UKE 3DDRESS CORRECTIONS ON THE TOP OE THIS FORH.

PLEASE C.ONT AC T ' THI S ' CF F ICE IF OWNE RSHIP H AS CH AhGED.'

1 e

(5. 'RETU% THIS FORM IN THE E NCLOSED EfNE LOPE.(F OS T AGE.R EQUIR ED).

R e-.

e.,

...mme

I Maryland Department of Natural Resources El 16 Water Resources Administration William Donald Schaefer G "" '

Tawes State Office Building Annapolis, Maryland 21401 Torrey C Brown. M.D DNR TTY for Deaf: 301-974-3683 Catherine P. Stevenson Dinctor "ERMIT CA71S001-MAKE NAME/ ADDRESS CH ANGES B ELOW BSLTIMORE GAS & ELECTRIC ATTN:

P.

T.

CRINIGAN CALVEDT CLIFFS LUSBY, MO 20657 DEAR CEPMITTEE:

55 A C L'JDI T I Qi 0F YOU4 M A C Y L A'.C W E T ER APPROPRIATION At.C USE PERMIT YOU ARE REQUILED T3 REPO:T YOUP n' a T E k WITHDDAWAL E VEP Y SIX MONTHS.

COMPLETF AND RETUc\\

, T H I S C O C NO LATEF, Tnti JULY 31, 1992.

Ir YOU HAVr NY OUESTIONS CCNCER%ING TulS F0DM, PLEASE TiLiFMINE THE WiTEP RIGH TS O!VISIO*J AT ( 3 *t l ) 974-2456.

199 2 S E9I-A %U! L WETED W ITHDR AW A L REPCPT 1.

CdECK TH; METdCD USFD TO DETERMINE YOUR WI THD R A>'L L AMOUNTS:

( 3 r LC;. v.E T E F f ) ELAPSE TIME INDICAT0k

( )O ? T H E *< ( E xPLt. I N) llourly computer printout with daily average 2.

E' TER THE NUvhER OF G A L L C ',' S OF WLTER WITHORAWN F0D EACH MONTH.

IF YOU HAVE MULTIPLE I% TAKES UNDER THIS PERMIT, PLEASE ACD TOGETHER THE MONTHLY TOTALS FOS

f. L L INTAKES.

DO NOT LIST CONTINUOU3 METER PE ADINGS, 40VDS PUMPEO, OP GALLONS IN MG2.

I 106948000000 51900000000 JANUARY 1992..................

A PR IL 1992.........................

200340000000 53491000000 I

FEBRUARY 1992..................

MAY 1992.........................

0671MM00 92330000000 MARCH 1992..................

JUNE 1992.........................

455680000000 TOTAL.................................

3.

PLEASE SIGN AND TE O

DATE..

SUBMITTED BY.

General Su Y. L t. P HON E NU M B ER.410-260-4729 T I T L E...........pe rvisor - Chemie t y,,

4

'1LKE ADD-ESS CORRECTIONS ON THE TOP OF THIS FORM.

I PLEASE CONTACT THIS OF FICE Ir OWNERSHIP HAS CHANGED.

I t

l b.

RETUPN THIS FORM IN THE ENCLOSED ENVELOPE (F 3ST AGE REQUIRED).

ronry c. stoww. u o.

' $s\\

JAurs w. eccx ese m as, l

e.aec, JOHN 2 4RIFFIN

.trutt sataavaev l

STATE OF MARYLAND DEPARTMENT OF NATURAL RESOURCES WATER RESOURCES ADMINISTRATION TAWES STATE OFFICE BUILDING Y

ANNAPOLIS, MARYLAND 21401 k

PERMIT CA71S001 MAKE NAME/ ADDRESS CHANGES BELOW BALTIMORE GAS & ELECTRIC ATTN: P.

T. CRINIGAN C'LVERT CLIFFS LUSBY, MD 20657 4

O D EAR PERMITTEE:

AS A CONDITION OF YOUR HAR.YLAND WATER APPROPRI ATION AND USE PERMIT YOU ARE REQUIRED TO REPORT YOUR WATER WITHDRAWAL EVERY SIX HONTHS.

COMPLETE AND RETURN THIS FORM NO LATER THAN JANUARY 31, 1993.

IF YOU HAVE ANY OUESTIONS CONCERNING THIS FORM, PLEASE TELEPHONE THE W ATER RIGHTS DIVISION AT (41C) 974-2456.

1992 SEMI-ANNUAL WATER WITHDRAWAL REPORT 1.

CHECK THE HETHOD USED TO DETERMINE YOUR WITHDRAWAL AMOUNTS:

( ) FLOW HETER

( ) ELAPSED TIME INDICATOR (X ) 0 THE R (EXPL AIN) Ilourly computer printout with daily average 2.

ENTER THE NUMBER OF GALLONS OF WATER WITHDRAWN FOR EACH HONTH.

IF YOU HAVE HULTIPLE INTAKES UNDEP THIS PERMIT, PLEASE ADD TOGETHER THE MONTHLY TOTALS FOR ALL INTAKES.

- DO NOT LIST CONTINUOUS HETER RE ADINGS, HOURS PUMPED, OR GALLONS IN HGD.

53249 JULY 19 9 2........p00p00 104509000000 OCTOB ER 1992.....................'....

95115000000 102658000000 AUGUST 1992..................

NOVEMBER 1992.........................

1030380000 107260000000 SEPTEMBER 19 9 2.....'.....'.00 DECEMBER 1992...........>.............

570829000000 TOTAL 3.

PLEASE SIGN AND TE FORM.

DA,E...w.a..........

SU -,,ED,,..

TI TLE.. General Supervisor - ChemiservTfL'EP HON E NU He ER..... 0-4729 410-26

~

4.

H AKE ADDRESS CORRECTIONS ON THE TOP OF THIS FORN.

PLEASE CONTACT THIS OFFICE IF OWNERSHIP HAS CHANGED.

Te hone RETURN THIS FQpft,,pj,f,gqq:q pgEp gggyg gpy,T,g[,,R EQUIR ED).

5.

e

't Maryland Department of Natural Resources

'*)

Water Resources Administration William Donald Schaefer G""

Tawes State Office Building Annapolis, Maryland 21401 Torrey C. Brown, M.D.

DNR TTY for Deaf: 301 974-3683 Catherine P. Stevenson Dinctor PERMIT CA71S001 MAKE NAME/ ADDRESS CHANGES BELOW BALTIMORE GAS & ELECTRIC ATTN:

P.

T. CRINIGAN CALVERT CLIFFS LUSBY, MD 20657 DEAR PERMITTEE:

AS.A CONDITION OF YOUR MARYLAND WATER APPROPRIATION AND USE PERMIT YOU ARE

] R EQUIRED TO REPOR T YOUR W ATER WITHDR AWAL EVERY SIX MONTHS.

COMPLETE AND RETURN

-THIS FORM NO LATER THAN JULY 31, 1993.

IF YOU HAVE ANY OUESTIONS CONCERNING T

IS FORM, PLEASE TELEPHONE THE WATER RIGHTS DIVISION AT (410) 974-2456.

v 199 3 SEMI-ANNUA L WA TER W ITHDR AW A L R EPOR T 1.

CHECK THE METHOD USED TO DETERMINE YOUR WITHDRAWAL AMOUNTS:

( > FLOW MET ER

( ) EL APSED TIME INDICATOR 1

(X ) 0THE R (EXPLAIN) Hourly computer printout with daily average.

l 2.'

ENTER THE NUMBER OF GALLONS OF WATER WITHDRAWN FOR EACH MONTH.

IF YOU HAVE MULTIPLE INT AKES UNDER THIS PERMIT, PLEASE ADD TOGETHER THE MONTHLY TOT ALS FOR ALL INT AKES.

- DO NOT LIST CONTINUOUS METER RE ADINGS, HOURS PUMPED, OR GALLONS IN MGD.

50740900000 JANUARY 1993. 107035100000 APRIL 1993.........................

19 93.. 56986200000 FEBRUARY 1993. 84856500000 MAY MARCH 1993. 53405100000 JUNE 199 3... 3766000000 9

446789800000 TOTAL.................................

3.

PLEASE SIGN AND DA E THIS

.0

../.

D AT E.. 7/.22/93 SUBMITTED BY G

TITL E.Gener.al Supervisor - ChemistVELEP HONE NUMBER. 10-260-4729 4

4.

MAKE ADDRESS CORRECTIONS ON THE TOP OF THIS FORM.

PLEASE CONTACT THIS OFFICE IF OWNE RSKIP H AS CH ANGED.

5.

RETURN THIS FORM IN THE ENCLOSED ENVELOPE (POSTAGE REQUIRED).

i

~ ~.

i DEPARTMENT OF NATURAL RESOURCES WATER RESOURCES ADMINISTRATION ROBERT D. NILLER, DIRECTOR TAWE5 STATE OFFICE BUILDING ANNAPOLIS, MARYLAND 21401

'A Commitment to Excellence in Managing Maryland's Vater Resources

  • l DECEMBER 17, 1993 1

Permit CA71S001(02)

    • SURFACE WATER PERMIT **

Make Name/Addrets Changes Below BALTIMORE GAS & ELECTRIC ATTN

,P. T. CRINIGAN CALVERT CLIFFS

'i LUSBY, MD 20657

)

j Dear Permitteet As a condition of your Maryland Water Appropriation and Use Permit you are required to report your water withdrawal every six months.

Complete and return this form no later than January 31, 1994..If you have any questions concerning this form, please telephone the Water Rights Division at (410) 974-2456.

1993 SEMI-ANNUAL WATER WITHDRAWAL REPORT 1.

Check the method used to determine your withdrawal amounts:

)

( ) Flow Meter

( ) Elapsed Time Indicator (X) Other (Explain) Hourly ccmput.er printout with daily average.

2.

Enter the number of gallons of water withdrawn for each month.

- If you'have multiple intakes under this permit, please add together the monthly totals for all intakes.

- Do not list continuous meter readings, hours pumped, or gallons in mgd.

- Indicate a "0"

for each month with no withdrawal.

L July 1993 107.260.000,300 October 1993 106.464.000.000 August 1993 106,239,000,000 November 1993 103,696,000,000 September 1993 103.333 300.000 December 1993 103.246.000.000 2

Total, 630,238,000,000 3.

Please sign and da e t s form.

j Submitted By:

/

b Date:

January 24, 1994 l

V

Title:

General Supervisor-Chemis$gybphone Number 410-260-4729 4.-

Make address corrections on the top of this form.

Please contact this office if ownership has changed.

5.

Return this form in the enclosed envelope (Postage Required).

\\

J o

"r DEPARTMENT OF NATURAL RESOURCES WATER RESOURCES ADMINISTRATION ROBERT D. MILLER, DIRECTOR TAWES STATE OFFICE BUILDING

)

ANNAPOLIS, MARYLAND - 21401 "A Commitment to Excellence in Managing Maryland's Water Resources" June-6, 1994 Permit _CA715001(02)

    • SURFACE WATER PERMIT **

l Make Name/ Address Changes Below BALTIMORE GAS & ELECTRIC 1

ATTN: P. T. CRINIGAN

-CALVERT CLIFFS LUSBY, MD 20657 A

Dear Permitteet As a condition of your Maryland Water Appropriation and Use Permit you are required to report your water withdrawal every six months.

Complete and return this form no later than July 31, 1994.. If you have any questions concerning this form, please telephone the Water Rights Division at (410) 974-2456.

1 1994 SEMI-ANNUAL WATER WITHDRAWAL REPORT

'I.

Check the method used to determine your withdrawal amounts:

( ) Flow Meter

( ) Elapsed Time Indicator (X) Other (Explain) Hourly computer printout with daily average.

2.

Enter the number of gallons of water withdrawn for each month.

- If you have multiple intakes under this permit, please add together,the monthly totals for all intakes.

- Do not list continuous meter readings, hours pumped, or gallons in mgd.

- Indicate a "O" for each month with no withdrawal.

January 1994 97.243.000.000 April 1994 62.401.000.000 February 1994 62,851,000,000 May 1994 100,565,000,000 March

~1994 48,440,000,000 June 1994 101,932,000,000 473,432,000,000 Total:

3.

Please sign and d this form.

l Submitted By:

[

M dad Date

  1. 7 o

l l

l

Title:

C'"* SUPV- - Chemistry Telephone Number 410-260-4729 4.

Make address corrections on the top of thi s form.

Please contact this office if ownership has changed.

5.

Return this form in the enclosed envelope (Postage Required).

\\

I

. ~ - -..

a DEPARTNENT OF NATURAL RESOURCES WATER RESOURCES ADMINISTRATION ROBERT D. MILLER, DIRECTOR TAWES STATE OFFICE BUILDING ANNAPOLIS, MARYLAND 21401 1

'A Commitment to Excellence in Managing Maryland's Water Resources

  • December 5, 1994 Permit CA718001(02)
    • SURFACE WATER PERMIT **

Make Name/ Address Changes Below 8ALTIMORE GAS & ELECTRIC ATTN P. T. CRINIGAN CALVERT CLIFFS LUSBY, MD 20657 Dear Permitteet 1

As a condition of your Maryland Water Appropriation and Use Permit you are required to report your water withdrawal every six months. Complete and return this form no later than January 31, 1995.

If you have any questions concerning i

this form, please telephone the Water Rights Division at (410) 974-2456.

1994 SEMI-ANNUAL WATER WITHDRAWAL REPORI 1.

Check the method used to determine your withdrawal amounts:

( ) Flow Meter

( ) Elapsed Time Indicator (X) other (Explain) Hourly computer printout with daily average.

2.

Enter the number of gallons of water withdrawn for each month.

- If you have multiple intakes under this permit, please add together the monthly totals for all intakes.

- Do not list continuous meter readings, hours pumped, or gallons in mgd.

- Indicate a "0"

for each month with no withdrawal.

July 1994 101,084,000,000 October 1994 104.423.000.000 l

August 1994 104,406,000,000 November 1994 100,824,000,000 September 1994 102,381,000,000 December 1994 107,260,000,000 Total:

620,378,000,000 3.

Please sign and date this form.

l Submitted By.

No 4

/uh Dates

/

f//T l

I '

)

/

/

l Title General Supervisor - Chem. Telephone Number: 410-260 4729 4.

Make address corrections on the top of this form.

Please contact this office if ownership has changed.

5.

Return this form in the enclosed envelope (Postage Required).

\\

l' i

.- -.- _ _.... -. - ~. -

j y_

i

~.

DEPAR2 MENT CF MATURAL RESOURCES SULTER RESOURCES ADMINISTRATION i

ROBERT D. MILLER, DIRECTOR f

TAWES STATE OFFICE BUILDING A3OULPOLIS, MARYIAND 21401 "A coanniement to Excellence.in managing Maryinad's Wated Resources

  • 1 May 22,1995 Permit CA718001(02)
    • SURFACE WATER PERMIT **

l Make Name/ Address changes Below RALTIMORE GAS & ELECTRIC ATIN: P. T.-CRINIGAN CALVERT CLIFFS LUSBY, MD, 20657 j

1 Dear Permittees As a condition of your Maryland Water Appropriation and Use Permit you are 4

required to report your water withdrawal every six months. Complete and return this form no later than July 31, 1995. If you have any questions concerning this form, please telephone the Water Rights Division at (410) 974-2456.

1995 SEMI-ANNUAL WATER WITHDRAWAL REPORT 1.

Check the method used to determine your withdrawal amounts:

( ) Flow Meter

( ) Elapsed Time Indicator (X) other (Explain) Hourly computer printout with daily average.

2.

Enter the number of gallons of water withdrawn for each month.

- If you have multiple intakes under this permit, please add together the monthly totals for all intakes.

- Do not list continuous meter readings, hours pumped, or gallons in agd.

- Indicate a *0* for each month with no withdrawal.

104338000000 April 1995 51840000000 January 1995 February 1995 106644000000 May 1995 93412000000 March 1995 June 1995 101164000000 86638000000 Total:

544086000000 3.

Please sign and d to is ora.

7o77k Submitted Ry:tt Date:

V

//

//

Title:

General Supervisor -(Chem. Telephone Numbers 410-260-4729 4.

Make address corrections on the top of this form.

Please contact this office if ownership has changed.

5.

Return this form in the enclosed envelope (Postage Required).

I 5

&5

(

MARYIAND DEPARTMENT OF THE ENVIRONMENT WATER )(ANAGEMENT ADMINISTRATION 2f50D BP.OENING HIGHWAY.

BALTINORE, MARYIAND 21224 December 1 1995 Regarding Water Appropriation and Use Permit CA71S001(02)

Make Name/ Address Changes Below BALTIMORE GAS & ELECTRIC ATTN: P. T. CRINIGAN Baltimore Gas and Electric Company CALVERT CLIFFS Calvert Cliffs Nuclear Power Plant LUSBY, MD 20657 1650 Calvei-t Cliffs Parkway Lusby, Maryland 20'657 ATTN: C.E. Earls Dear Permitteet As a condition of your Maryland Water Appropriation and Use Permit you are required to report your water withdrawal every six months.

Complete and return this form no'later than January 31, 1996.

If you have any questions concerning this form, please telephone the Water lights Division at (410) 631-3591.

1995 SEMI-ANNUAL SURFACE WATER WITHDRAWAL REPORT 1.

' check the method used to determine your withdrawal amounts:

( ) Flow Meter

( ) Elapsed Time Indicator (X ) Other (Explain) Hourly computer printout with daily average.

2.

Enter the number of gallons of water withdrawn for each month.

- If you have multiple intakes under this permit, please add together the monthly totals for all intakes.

- Do not list continuous meter readings, hoars pumped, or gallons in mgd.

Indicate a "O" for each month with no withdrawal.

July 1995 106686000000 October 1995 106107000000 August 1995

.106482000000 November 1995 __102020000000 September.1995 103386000000 December 1995 106753000000 Tot'al:

631434000000 3.

Please sign and date th a rm.

M c. re l.i Dates y /.ro/f(

Submitted By:

Titles ~ General Supervisor - Chem. Telephone Number 410-495-6787 4.

Make address corrections on the top of this form.

Please contact this office if ownership has changed.

5.

Return this form in the enclosed envelope (Postage Required).

e a

5

I MARYIAND DEPARTMENT CF THE ENVIRONMENT WATER MANAGEMENT ADMINISTRATION WATER, RIGHTS DIVISION 2500 BROENING HIGHWAY BALTIMORE, MARYLAND 21224

/

June 10, 1996 Regarding Water Appropriation and Use Permit CA71S001(02)

Make Name/ Address changes Below BALTIMORE GAS & ELECTRIC COMPANY ATTN:

C..E.

EARLS 1650 CALVERT CLIFFS PARKWAY LUSBY, MD 20657

Dear Permittee:

As a condition of your Maryland Water Appropriation and Use Permit you are required to report your water withdrawal every six months.

Complete and return this form no later than July 31, 1996.

If you have any questions concerning this form, please telephone the Water Rights Division at (410) 631-3591.

1996 SEMI-ANNUAL SURFACE WATER WITHDRAWAL REPORT 1.

Check the method used to determine your withdrawal amounts:

( ) Flow Meter

( ) Elapsed Time Indicator (X ) Other (Explain) Hourly computer printout with daily average.

2.

Enter the number of gallons of water withdrawn for each month.

- If you have multiple intakes under this permit, please add together.the monthly totals for all intakes.

- Do not list cont'nuous meter readings, hours pumped, or i

gallons in mgd.

- Indicate a "0" for each month with no withdrawal.

106433000000 52.765000000 January 1996 April 1996 February 1996

~

Hay 1996 53630000000 t

March 1996 103236000000 51675000000 June 1996 Total:

3.

Please sign and date this form.

7!)S" Submitted By:

Date Title General Supe r - Chem Telephone Number: 410-495-6787 4.

Make address corrections on the top of this form.

Please contact this office if ownership has changed.

5.

Return this form in the enclosed envelope (Postage Required).

s L

s I

. MARYIJufD DEPARTMENT CF TEE ENVIRONMENT i

WATER MANAGEMENT ADMINISTRATION WATER RIGHTS DIVISION 2500 BROENING HIGHWAY BALTIMORE, MARYLAND 21224 December 13, 1996 Regarding Water Appropriation and Use Permit CA71S001(02) i Make Name/ Address Changes Below BALTIMORE GAS & ELECTRIC COMPANY ATTN: C. E. EARLS

~1650 CALVERT CLIFFS PARKWAY LUSBY, MD-20657

-l f

- Dear Permitteet As a condition of your Maryland Water Appropriation and Use Permit you are required to report your water withdrawal every six months. Complete a'nd return-this form no later than January 31, 1997.

If you have any questions concerning-thisLform, please telephone the Water Rights Division at (410) 631-3591.

1996 SEMI-ANNUAL SURFACE WATER WITHDRAWAL REPORT 1.

Check the method used to determine your withdrawal amounts:

( ) Flow Meter

-(

) Elapsed Time Indicato (X) Other (Explain) Hourly computer printout with daily average.r 2.

Enter the number of gallons of water withdrawn for each month, i

- If you have multiple intakes under this permit, please add j

together the monthly totals for all intakes.

- Do-not list continuous meter readings, hours pumped, or gallons in mgd.

- Indicate a "0" for each month with no wi,thdrawal.

106569000000 July 1996 58961000000 october 1036 August 1996 106230000000

~

November 1996 98212000000 September 1996 103125000000 December 1996 107035000000 Total:

580132000000 3.

Please sign and date this fo Submitted By:

M Dates [M General Supervisor - Chem.

410-495-6787

Title:

elephone Numbers

^4.

Make address corrections on the top of 'this form.

Please contact this office'if ownership has changed.

\\

'(

MARYI.AND EEPARTMENT CF THE ENVIRONMENT WATER MANAGEMENT ADMINISTRATION WATER RIGHTS DIVISION 2500 BROENING HICHWAY BALTIMORE,' MARYLAND 21224 July 8, 1997 Regarding Water Appropriation and Use Permit CA71S001(02)

Make Name/ Address Changes Below BALTIMORE GAS & ELECTRIC COMPANY ATTN: C.

E.

EARLS 1650 CALVERT CLIFFS PARKWAY LUSBY, MD 20657

Dear Permittee:

required to report your water withdrawal every six months.An a condition of yo this form no later than July 31, 1997.

Complete and return this form, please telephone the Water Rights Division atIf you have any questions concerning (410) 631-3591.

1997 SEMI-ANNUAL SURFACE WATER WITHDRAWAL REPORT 1.

Check the method used to determine your withdrawal amountos r

( ) Flow Meter

( ) Elapsed Time Indicator (X) Other (Explain) Hourly computer printout with daily average.

'2.

Enter the number of gallons of water withdrawn for each month.

l

- If you have multiple intakes under this permit, please add together the monthly totals for all intakes.

- Do not list continuous meter readings, hours pumped, or gallone in mgd.

s

- Indicate a "O" for each month with no withdrawal.

January 1997 1068 M 00000 April 1997 00000000 February 1997 93516000000 May 1997 73468000000 March 1997 79805000000 June 1997 102561.000.000 Total:

508064000000 3.

Please sign and date t i form.

Submitted By:

g (C.E. Earls Q,

7,, g y7

Title:

Cen. Supv. - Chem.

Telephone Number 410-495-6787 4.

Make addroso corrections on the top of this form.

Please contact this office if ownership has changed.

.. ~

\\

,/

.~, -. --

MARYLAND ' DEPARTMENT CF THE ENVIRONMENT WATER MANAGEMENT ADMINISTRATION

.NATER RIGHTS DIVISION 2500 BROENING HIGHWAY BALTIMORE, MARYLAND 21224 January 22, 1998 Regarding Water Appropriation and Use Permit CA715001(02)

Make Name/ Address Changes Below BALTIMORE GAS & ELECTRIC COMPANY ATTN C. E. EARLS 1650 CALVERT CLIFFS PARKWAY LUSBY, MD 20657 l

l l

Dear Permittees As a condition of your Maryland Water Appropriation and Use Permit you are required to report your water withdrawal every six months..

Complete and return this form no later than January 31, 1998.

please telephone the Water Rights Division at (410) 631-3591.If you have any this form, 1997 SEMI-ANNUAL SURFACE WATER WITHDRAWAL REPORT 1.

Check the method used to determino your withdrawal amounts:

( ) Flow Meter

( ) Elapsed Time Indicator

( g Other (Explain) llourly computer printout with daily average.

2.

Enter the number of gallons of water withdrawn for each month.

- If you have multiple intakes under this permit, please add together the monthly totals for all intakes.

- Do not list continuous meter readings, hours pumped, or gallons in mgd.

- Indicate a "0" for each month with no withdrawal.

July 1997 106862100000 106083600000 october 1997 August 1997 106689316308 l

November 1997 102487888708 September 1997 Q2884365358 December 1997 106413186625 Total:

621420456999 3.

Please sign and da e this form.

Submitted By:

1

  • A.Yoyate

/b9/9ff

/

Title:

General Supt r - Chemrelephone Number 410-495-4741 4.

Make address corrections on the top of this form.

Please contact this office if ownership has changed.

t l

\\

3s

,s.

MARYLAND DEPARTMENT CF THE ENVIRONMENT NATER MANAGEMENT ADMINISTRATION WATER RIGHTS DIVISION 2500 BROENING HIGEWAY BALTIMORE, MARYLAND 21224 June 15, 1998

,Regarding Water Appropriation and Use Permit CA71S001(02)-

Make Name/ Address ~ Changes Below BALTIMORE GAS & ELECTRIC COMPANY

. ATTN C. E. EARLS 1650 CALVERT CLIFFS PARKWAY LUSBY, MD 20657 I

i l

I Dear Perr.titteet As a ccndition of your Maryland Water Appropriation and Use Permit you are J

required to report your water withdrawal.every six months. Complete and return

)

this form no later than July 31, 1998.

If you have any questions concerning this form, please telephone the Water Rights Division at (410) 631-3591.

1998 SEMI-ANNUAL SURFACE WATER WITHDRAWAL REPORT 1.

Check the method used to deten ine your withdrawal amoents:

i

( ) Flow Meter

( ) Elapsed Time Indi'ator (X) Other (Explain) Hourly computer printout with daily as e.

2.

Enter the number of gallons of water withdrawn for each month.

- If you have multiple intakes under this permit, please add

)

together the monthly totals for all intakes.

j

- Do not list continuous meter readings, hours pumped, or t

L gallons in mgd.

- Indicate a "0" for each month with no withdrawal.

i January 1998 April 1998 59685000000 j'

February 1998 95271000000 May 1998 53630000000 March 1998 June 1998,

Total:

516604000000 l

3.

Please sign and d te this form.

Submitted By:

(C.E.Earlsdate:

7/KVf9B

Title:

General Supervisor - Chem. Telephone Number 410-495-6787 l

L 4.

Make address corrections on the top of this form.

Please contact this office if ownership has changed.

i i

i J

I l.

\\

4 i

ATTACHMENT (9) ENCLOSURE (I) 4 i

t i

1 1

i 1.

i-h POLK POWER STATION 1

TAMPA ELECTRIC COMPANY 4

EPA 904/9-94-002(A)

FINAL ENVIRONMENTAL IMPACT STATEMENT, VOLUME I JUNE 1994 Page 2-60 Baltimore Gas and Electric Company Calvert Cliffs Nuclear Power Plant November 20,1998

r..

~

$fffNll,",.'.S'$95PR/95F f

ih

,i

'x:%3;.:-:.:hn,.V6 x a%; ~.LA.

  1. :Un&,. %;.

~

A

~

h' f

Y 'h 5.hff M8,W;$;*lpgEPA;904/9-94-002 fdfc

% d Street NET

. i Envlte,d Qt,atps f.ge.f; tion'f5%4%

. ironmental Protec a

dJune 1994 rtlan

th. ; A: Agency :

l.l'<-

",8fA5aiitiddA 30'365

..w s

,gqg, -

1 l, ;',

,..~. OllW:Jf.' M:: 'pWsR$}MC a '

5. hc').s.'

l T

.:l

.,-u, i

g, M' *

< x ;, -.

e.f e w..:,..

i

.s j,$'ff,

,e

,,J',..

'. 'i y y.

w&.

.'.:.%w., ' st,&;;M(*2 f;;.v.,..

i V

~.r. ~ y, y g

w-.aa.. u,

,1 iCJC (r.

d M i, a.6.f, vi@' /ki;.

s t '.h, ~

b_.

k;.u;;;. %,g p,..[ll%

.M ':

,9;. i * '

+p,

.4._

e, s..y e.

.n s

, d; pgitl%

s'

' ;{Y U-S coVERNMENT.

Y Of

ahp
~.

yp eQ::

g.vv..

FINAlpp,.,,.w.

o US M

... 3. w,,,W.s,g:yy.m qlt4m'-

o y:,4 u

Sfji, 5 :s , w) ;.'. wng.w. e;r,\\? :- -

^

e.

x n,,-

ww not.6

, w*

-.~

4,11.0 mam.e.~'{fY> s

.. E t ! Q N%r<

0.

M, E,'d;

  • d'ik,A

,s a

s nv m

v

. Q --

w}Q 4.Y. ;Qt-

_,v. *, u

-q.Q.,;lj;;,;;*p; ' '.,. '

KG

,J

- Q_

s.i.

g.., f M..,. i m, p..r.c.,; va c t- _t g t wp :xmenR.

e. rn.

o t

ft Volume I: 'Re ort e

i 4

$.^

} %,., - Tampa Electric Company - Polk Power Station 1l

. T, g.n s

,?*

2 g_

h&:

f3, l.

g

..,, L L' _. 1

c. -

- om

-~

i/

FINAL ENVIRONMENTAL IMPACT STATEMENT POLK POWER STATION TAMPA ELECTRIC COMPANY

/

PROPOSED EPA ISSUANCE OF A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM PERMIT FOR A NEW SOURCE PROPOSED DOE' CLEAN COAL COST-SHARED FINANCIAL ASSISTANCE UNDER THE DOE CLEAN COAL TECHNOLOGY DEMONSTRATION PROGRAM Prepared by; U.S. ENVIRONMENTAL PROTECTION AGENCY l

In cooperation with:

U.S. DEPARTMENT OF ENERGY U.S. ARMY CORPS OF ENGINEERS ABSTRACT Tampa Electric Company proposes to construct and operate a 1,150-MW power station in southwestem Polk County, Florida. The proposed Polk Power Station would require an EPA NPDES permit for a new source arid would include a 260-MW IGCC unit as a DOE Clean. Coal Technology i

demonstration project.' This EIS document assesses the proposed project and'altematives with 4

respect to environmentalimpacts. Mitigative measures are also evaluated for the preferred attemative.

Comments or inquiries should be directed to:

Heinz J. Mueller, Chief Environmental Policy Section U.S. Environmental Protection Agency, Region IV 345 Courtland Street, Northeast / Atlanta, Georgia 30365 (404) 347-3776 / FAX (404) 347-5206 Approved by:

D%

Ally 2A, Mf4 John H. Hankinson, Jr.

Date Regional Administrator U.S. Environmental Protection Agency Region IV

\\

i operated in CC mode. NO, emissions from the remaining IGCC facility combustion sources would be 5

controlled by using low-NO, burners and/or good combustion practices that reduce NO, formation.

p The stand-alone CC and CT units would be equipped with dry, low NO, bumers when fired on natural gas.

Water injection would be used when the CC and.CT units are being fired on backup distillate fuel oil.

2.3.6 condenser Cooline Water System The steam electric-generating components of Polk Unit I and two CC units require water to cool or condense i

i the exhaust steam from the STs.' The cooling water carrying the waste heat retums to the cooling water i

I reservoir where waste heat is ultimately released into the air.

a Re proposed cooling reservoir would be constructed in areas previously mined for phosphate and currently i

filled with water. De total size of the reservoir, including the surrounding and intemal earthen berms, would be approximately 860 acres After final contouring and development of the site, the reservoir would be a primarily below-grade facility. The avecage and maximum' elevations of the reservoir's bottom would be about 120 feet National Geodetic Vertical Datum (ft-NOVD) and 123 A-NGVD, respectively. Under nonnal operations, the cooling reservoir water level would be approximately 136*0.5 ft NGVD. The total water surface area is estimated to be 727 acret,(,;.46 acres /MW of ST generating capacity). De surrounding berms j-would be 145 ft-NOVD high with a width of 25 ft at the top to provide access for inspection and maintenance. The intemal berms would have a top elevation of 141 ft-NGVD and a top width of 17 ft. The ratio of the berm slope is 1:4 (1 ft vertical to 4 ft horizontal) to minimize potential erosion and visual quality effects. Berms will be revegetated and maintained after construction to prevent future erosion.

Intake and discharge structures would be constructed to provide adequate flow channels to allow condenser cooling water to enter and/or leave the reservoir. The required circulating and condenser cooling water flows are nearly 115,800 gallons per minute (gpm) for the Polk Unit 1, including the air separation unit. A total flow rate of 247,000 gpm would be required after the two CC units are in operation.

A cooling water intake structure would be located in the northern portion of the reservoir to supply water to the condenser cooling systems of the ST generating units. The water would be warmed to about 20*F above its intake temperature due to heat exchange during the cooling process. This warmed water would be discharged back to the reservoir at a location south of the intake. The discharged warm water flow would meander through the channelized reservoir, mixing with the cooler water. Meanwhile, the waste heat would be convectively transferred to the surrounding cooler water, and it eventually would be released into the air through radiation, evaporation, and heat transfer between the water and the atmosphere. Therefore, the teenperature of the water body at the intake of the cooling water reservoir would always be sufficiently low and ready for reuse.

2-60 TECO(WP) Chap 2\\ Test 052794

\\

, - - - ~..,,...

ATTACHMENT (9) ENCLOSURE (J) 1 THE BEAVER COMBINED CYCLE COMBUSTION TURBINE GENERATING PLANT INFORMATION BROCHURE DISTRIBUTED BY:

PORTLAND GENERAL ELECTRIC i

)

Baltimore Gas and Electric Company Calvert Cliffs Nuclear Power Plant November 20,1998

T

.: +a

)

Q-

?.

i i

The BeaverL'ombined t

t-l Cycle Combustion

{

Turbine GeneratingPlant i

A j

600,000 Kilowatts ofVitally I

Needed Electricity b

M

, Q % y. M c ~~..

L

y. %

.u

,J ~a;b

\\

='5;;b

%; Y,.

c

, +..

?.

f g

4 1

,0, l

.A-

-r

j w

~..

01 Y-

?lhh115%.,;;_-.

3 l

_::.b@

i w m w nt w w.w,yu a u.aw..a w eca w.o,,

}

i Recycles exhaustheat to pmduce 150,000 Idiowatts ofpower without j

burning a single extra dmp offuel.

AnotherOn.gon first by m

ammu l

"E

\\

s

@\\

l Commnuun sursnne tavnsu1scuin cs sserver generating plant 3 Construction of the Buyer 450 quick ta build, quick gm, watt Simple Cyrie Combusti:n nePortionofthe plantwasbegun 4.

to produce power To supplement conventional base-In early 1973, when the Paclfic load generating plants-powered by Northwest was confmnted with a crit-hydro, nuclear or coal-and to keep l~ cal shortage of existing generatine pace with the constantly increrJng capacity. It was decland commercial electrical needs of new customers in August,1974-ready to run in less coming on Company lines, Portland than 14 months. Work on the 150 General Electdc has completed con, megawatt Combined Cycle turbine-struction of its 600 megawatt Com. generator add-on was begun in May, blned Cycle Combustion 'Ibrbine 1975 and declared commercial, Octo-Generating Plant. It is the world's ber 31,1977. Fmm plans to "on line" largest Combined Cycle generatina 5eneration, the elapsed time for the plant and fulfills an important ang entire plant was less than four years.

necessary role in the region's power Conventional base-load plants using needs at a time when it is sorely hydm, nuclear or fossil fuels, take needed.

anywhere fmm 7 to12 years tolicense PGE turned to this type plant-as and build.

have many other utilities thmughout the country-primarily because they Used ihrpeaking and can be built and put on line at a rela-einerg'ency operation tively low plant cost in a short time In normal peaking operations, Bea-frame. Other advantages are that the verb Simple Cycle generating system i

Simple Cycle, fast-start portion of the can be pnxlucing power to base load plant can be " flipped"into produedon in 20 minutes. In an emergency situa.

in a matter of minutes to meet equally tion,it can attain base load in 10 min-quick-happening energy emergen. utes. As the Combined Cycle unit cies.'ntrbine plants are extremely use. utilizes the exhaust (otherise waste) '

4 ful for reserve generation in'the event heat fmm the six Simple Cycle tur-of water shortfalls or when other bines,its additional 150,000 kilowatts

?

generating resources are down. Com. can supply base load fmm a warm bustion turbines have the capabilityof start in two hours from a " hot" start,

)

i burning diveme fuels to with to. in 50 minutes.

day's changing fuel su market.

With the recently com d Com-bined Cycle t.ddition,the Beaver plant can generate an additional 150000 kilowatts of electricity without burn-ing a single extra drop of fuel.

l b

e

\\

2 l

Bezver... wcrid's largest combined cycl 2 pow:r plant QTWW W

.2_% n.

E,0* '

f.W.. Q '

p

(}l5[5$

$4

~

p j

M

,. ' g"

,Jc.f *'

Y h,

^

i

!YA s.7 d.edhe. D.e.N.4 3,

Ohi[

1 I

f 7

,t %c....

a E

Tg ca. um,.

a.omew w.w ce n,,u,,,

u, n.,u,,,

,j ssWy 3sq ou %,e,.

4

/% SMaMant wo nwarmens sus suY. cY, e r.

l Six combustion turbines rated at Simple Cycle turbine has its own 1

92,000 horsepower each, combine to boiler and thus can be run as inde- -

(

generate 450,000 kilowatts ofelectric-pendent, tandem or triple units to feed ity in the Simple Cycle.tage ofBeaver, the large add-on steam turbine. There i

One, two, ihree or all six turbh.-s can are six IIRSG's one for each combus-j be used, depending upon the tion turbine in the Simple Cycle plant.

emergency needs ofPGE customers or The resultant steam is combined in j

the ex?cnt of a power short-fal) from a funnel of force to spin the blades of other generating plants in the region. the 150,000 kilowatt turbine-i The Con.bined Cycle additian to the generator which is located in the tur-

]

plant uses :he extremely het exhaust bine building of the Combined Cycle gases (abost 1,000 degrees portion of the plant. The steam used j

Fahrenheit) fro n 6e six turbines by for generation is confmed within a i

routing them throu l

Steam Generators (p. IIcat Recovery closed loop system and after working 1IIGG) (see dia-it., av th uugh the giant turbine-pn:n) to p:oduce steam to sp:n the generaar, is converted back into turbine to turn the generator to gain water by the condenser and used over the 150,000 " bonus" kilowa'ts. Each again.

o' O

-- - -~

(

Fuel tt:rzg3 facilities Air, wet:r, n:ise controls On :n's larg:ct m:et federal, sixts The ant's turbines cc.n burn a vari-standarsi3 ety o fuels-from conventional cir. The Beaver plant was designed and craft fuelto #2 diesel-the same dict built to meet the stdct standartis of 2

is used in home heating furnaces. - both FederalandState Envimnmental They also can use crude and residual Contml agencies. Sophisticated fuel l

oils. On-site, bulk oil storage consists and water clarification systems 'are l

of four 250,000-barrel capacity ~ utilized for pmtection of the plant's welded steel tanks which can be filled fuelburning machinery and to main.

at the rate of10,000 barmis per hour tain air quality in the area. The small by barge or tanken Fueldelivedes can emissions from the turbine stacks are be made by rail,truckorbarge.There controlled effectively to meet all gov-are also two 100,000 barrel capacity ernment standants of air quality, dis-welded steel tanks for untreated fuel Noise fmm the plant is not storage uree more smaller,50,000 cernible when one stands at the barrel capacity tanks for treated fuel planti pug. ;y line. The swiftly spin-and for 72 distillate fuels make for a ning turbines are finely balanced and total of t,350,000 barmis ofoil storage quality engineemd so as to practically or more than 56 million gallons. eliminate both noise and vibration.

Maximum storage capacity is suffi-Oil collection and containment pits cient to run Beaver's turbines 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> have been cotatructed amund the fuel a day for 64 days.When generating at storage tanbi and valve outlets to full capacity, the turbines burn 882 minimize the possibility of fuel leaks barrels per hour. The fuel repmsents and escapage. Personnel operating an investment of close to $18 million.

the plant have been 6pecially trained 1

to handling potential problems of trcnsferring fuel fmm barges, railway cars or tank trucks to the storage tanks.

Landscaping is planned to blend the plant into the surmundings. The buildings and other components of the plant are "briney"gmen painted " forest" and the stacks desert tan.

1

\\

~ - -. -. -

I A look et plant corts Fuel to fire combustion turbines is Beaver plant facts dramatically more expensive than for Piantama occupies 120acresofa PGE

. coal and nuclear plants, but-lease / hold on a totalof 855 acres.

Portant power producing mie innts of this type serve an ex 450 Megawatts)

Pmviding quick, reliable plectric ser-Six General Electdc vice. Beaver was built to supplement combustion 'Ibrbines

/

3 an existing electrical generating net- (Wt.120 tons) work of hydro, fossil and nuclear (92,000 horsepower,each) power generating facilities and will be Six 83#00 Kva AirwCooled called upon to help meet peak and Generators intermediate load demands Four250,000 Barrel Capacity ing costa vary, of cousse, acco. Operal-Bulk Storage Tanks the length of time the turbines are inrthng to Two100#00 BarrelCapacity use.Iftheyare operated 3 500hoursa Bulk StorageTanks year, for example, power, costs would Three 50,000 Barrel Capacity be approximately 3.5e per kilowatt Insulated Storage 'Ibnks hour with the Combined Cycle in op-Four Electmstatic Pn.cipitator eration.These costs compare with.7C Vessels i

for hydm-pmduced power and 1.G5c Fuel Oil Heatingand Fire for power generated at the Trojan nu-Pmtection Systems clear plant. Capital costs of turbine Water and Waste Water plants are comparatively low, how-1Yeatment Systems ever. Beaver was built at a cost of$149 Start up11mes i

per kilowatt. This compared with NormalStart Mme to Base

'IYojan which came,in at about s

per kilowatt. And 'Itojan was a "$410 load-20 minutes bar.

gain" compared with similar or future Emergency Startilme to Base load-10 minutes nuclear plants. Costs of buildin5 nu-clear plants on the drawing boards i

now are estimated to cost more than

$1,000 per kilowatt.

i Total investment in the Beaver Combined Cycle generating plant is

$120 million.

l 1

i i

s

a combined cycle combustion turbine plant works:

SIMPLE CYCLE COM8tNED CYCLE Eshausi

/ l.N p

bt>ne Generasor i

ii 1

.--yi i

I n

DT

\\

1 Y

%enser l

Oefred Gas brt>nes Generators Oander nnnn (6)

(6)

' Heal Recovery I

Steam Generators pg

-f Coohng Towers Coenbined C,wle Mant one 170Doo Eva synchronous Generator start up'nenee Et 8

Plant Adden fueled tvkh Ebt Heat fiern 54rnple Cycle Systern rom start--50 adn es f:cenbusden Turbines MechanicalDraR Cooling Ttnwr Plant (tun enouths)

School plant tours available The Beaver plant Is located apbruxi-

< [ ' g '~' "'

/'

mately six miles north of Clats

  • ""*\\'

e.

~ ~'

Tmm the traffic light on Highway 30 l

in Clatskanie, turn north and follow

,,,yrn

~

signs indicating Port Westward and Beaver. Clatskanie is on Oregon State Highway 30, G3 rniles north and west l

of Portland. Teachers deshing to take their students on a guided tour of the plant may make reservations by call-CCET.

Ing PGE's Educational Representative 03\\

nt the Company's Portland headquar-ca -( ' N ters,226-8517. "Iburs are conducted on a pre-arranged basis during non-g' ',

operational hours.

-.___,,,s, sum sur r

I f

5 l

\\

l

j ATTACIIMENT (9) ENCLOSURE (K) 1 i

a

)

i t

1 l

j PERRYMAN POWER PLANT

\\

4 CERTIFICATION OF PUBLIC CONVENIENCE AND NECESSITY i

i.

j ENVIRONMENTAL REVIEW DOCUMENT, VOLUME 2 i

i Pages 3.2-1,3.2-2, and 3.3-1 1

1 Baltimore Gas and Electric Company Calvert Cliffs Nuclear Power Plant Novemher 20,1998

PER-RYMAN BALTIMORE POWER GAS AND ELECTRIC PLANT CERTIFICATION OF PUBLIC CONVENIENCE AND NECESSITY Q

ENVIRONMENTAL REVIEW DOCUMENT VOLUME 2 SUBMITTED BY:

BALTIMORE GAS AND ELECTRIC COMPANY g

~

~.

i I'

3.2 SITE LAYOUT AND FACILITIES DESCRIPTION j

3.2.1 GENERAL The proposed site plan for the Perryman Power Plant which shows the i

l project's configuration relative to the Perryman site is presented in Figure 3.2.1-1.

Figures.3.2.1-2 and 3.2.1-3 present the simple cycle and

. combined cycle configurations, respectively.

The plant will be located in the northern portion of the 719 acre site near i

the Amtrak corridor and east of the existing forested area. The simple and i

combined cycle phases will require, approximately 31 and 43 acres, respectively.

The facilities and their approximate areas at the completion of the combined cycle phase [i.e., 800 MW (nominal)) are:

Facility Area (acres)

Generating Plant 17 acres Access Roads 3 acres Fuel Storage 2 acres Switchyard 2 acres Cooling Towers 7 acres Miscellaneous 12 acres Total 43 acres Plant grade will be established at elevation 31 feet (ft) National Geodetic Vertical Datum (NGVD).

l 3.2.2 SIMPLE CYCLE PHASE

[

As shown in Figure 3.2.1-2 the cts and water treatment facilities will be located inside buildings. The combustion turbine building profile will be approximately 62 ft high over the combustion turbine area and approximately -

40 ft high over the generator area.

The cts will exhaust through a 100-ft high stack which will also be used as a bypass stack when simple cycle operation is desired after the combined cycle phase is complete.

l 3.211

=The transformer yard for each' combustion turbine unit will include a main step-up' transformer and unit auxiliary transformer. A startup transformer

~

will be installed for each combustion turbine pair.

The switchyard adjacent to each combustion turbine pair will include high-voltage breakers, disconnect switches, and associated buswork.

The three fuel oil storage tanks will be located within a bermed enclosure

'which will be provide'd to retain spills.

Each-oil tank will be 100 ft in diameter and 48 'ft high with capacity of 2.82 million Ballons (MG).

An 87-ft-diameter, 45-ft-high storage tank (2-MG capacity) for filtered water will be constructed for 24-hour storage of plant process makeup water from the on-s'ite well water system. -This tank will also include storage dedicated for the plant's fire protection system during the simple cycle

phase, t

The wastewater-treatment system will be located northwest of the power block area for. ease of discharge into the plant discharge pipeline to the 1

LBush River.

J j

^

3.2.3. COMBINED CYCLE PHASE The steam turbines for the combined cycle units will be located inside a common building. This building will be approximately 92 ft high by 190 ft long by 150 ft wide. The HRSGs will be located outside with provisions for noise abatement. Each of the four stacks will be 230 ft above grade.

i A 6-MG 150-ft-diameter, 45-ft-high raw water storage tank will be constructed for 24-hour storage of cooling tower makeup water. This tank will also' include water storage dedicated for the plant's fire protection system.

~

In the transformer yard, a main step-up transformer will be installed for each steam turbine unit. A main breaker, disconnect switches, and 3.212 i

m

i l

3.3 FUELS The primary fuel for the proposed Perryman Project will be natural gas, l

i which will be delivered to the site through an underground pipeline.

In addition, the combustion turbines will also be designed to burn No. 2 fuel oil which will be stored on-site as a secondary fuel.

The fuel oil receiving system will be designed to handle railroad and truck delivery.

3.3.1 NATURAL CAS The plant will receive natural gas through an extension of the existing gas distribution pipeline which is located north of the Perryman site.

A natural gas metering / filtering station will be constructed where the pipeline enters the site. This station will meter the gas quantity used, provide scrubbers to filter the gas of any entrained liquid or l

particulates, and adjust the supply pressure for use in the combustion turbine units as required. A representative analysis of the natural gas proposed for use is presented in Table 3.3.1-1.

g 3.3.2 FUEL OIL The fuel oil storage and supply system will include three fuel oil storage tanks, as well as fuel oil unloading and transfer pumps.

Fuel oil unloading facilities will be provided to accommodate both rail and truck delivery.

Rail is the preferred method of delivery.

One storage tank will be installed for the simple cycle phase, and two additional storage tanks will be installed for combined cycle phase operation.

Each fuel oil storage tank will have a capacity of 2.8 MG.

For spill protection and retention, the tanks will be located within a bermed area that will be designe,d to retain a tank rupture or any leaks which may occur during the transfer of fuel oil.

The bermed area design capacity will contain the contents of a storage tank should it rupture, plus 1 f t of additional freeboard. A typical analysis of the fuel oil proposed for use is l

presented in Table 3.3.2 1.

Fuel oil will be transferred from the unloading station to the storage tanks within a paved area. The unloading station area vill include a sump 3.341 l