Text

,

i TABLE 3A l

CALVERT CLIFFS NUCLEAR POWER PLANT l

EFFLUENT AND WASTE DISPOSAL SENI-ANNUAL REPORT l

FIRST HALF - 1989 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A.

SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (NOT IRRADIATED FUEL) 6-MONTH EST.10TAL 1.

Tvoe of Waste UNITS PERIOD ERRORE 3

a.

Dewatered spent resin m

.6.50E+00 Ci 1.19E+01 2.00E+01 b.

Dry Compressible Waste, m

1.39E402

[

3 Contaminated Equipment, etc.

Ci 7.16E+00 5.00E+01 i

3 c.

Irradiated Components, m

5.00E+01 Control Rods, etc.

Ci i

3 d.

Other(CVCSFilters) m 3.60E+00 C1 3.69E+02 2.00E401 f

l 2.

Estimate of Major Nuclides (By Type of Waste)*

a.

Manganese

-54 1.50E400 %

Iron

-55 2.60E+00 %

Cobalt

-58 9.90E+00 %

Cobalt 60 2.70E+00 %

Nickel

-63 3.50E+00 %

Cesium

-134 1.86E+01 %

Cesium

-137 5.90E+01 %

l b.

Iron

-55 4.10E+01 %

Cobalt

-58 3.20E+00 %

Cobalt

-60 1.40E+01 %

Nickel

-63 8.90E+00 %

Cesium

-134 8.30E+00 %

Cesium

-137 2.10E+01 %

  • Only nuclides greater than 1% are reported 3.

Solid Waste Disposition Number of Shioments Mode of Transoortation Destination 3

Motor Surface Transit Barnwell, S.C.

3 Motor Surface Transit Scientific Ecology Group Oakridge. 1N 9005070114 900430 PDR ADOCK 05000317 R