s

4-BALTIMORE i

GAS AND 1

ELECTRIC CHARLES CENTER e P.O. BOX 1475

  • BALTIMORE, MARYLAND 21203-1475 R E.DENToN GENERAL MANAGER April 24,1992 U. S. Nuclear Regulatory Comm.ssion Washingtor.,DC 20555 A'ITENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 Supplemental Semi-Annual Efnuent Release Report Gentlemen:

Enclosed please find the Supplemental Semi-Annual Effluent Release Report in accordance with Calvert Cliffs Units 1 and 2 Technical Specification 6.9.1.8. This update incluc's 'he strontium analytical results for the fourth quartu of 1991. This update also includes change La Attachments (2A), (3A), and Appendix B. Attachment (2A) was modified to include a continuous d3 charge containing only tritium that was not included in our original report. A typographic error was also corrected for the third quarter dilution water value. The change to Attachment (3A) was made to correct the original report because a selfidentified calculation error was discovered on several resin solid waste shipments. Appendix B was modified to remove the ODCM change 91-211 that was

- never approved in 1991,- Please replace the original pages with the enclosed pages.

Should you have any further questions regarding this matter, we will be_ pleased to discuss them with you.

V

% ery truly yours, r

w RED /JAS/CDS/bjd Enclosure cc:

D. A. Brune, Esquire J. E. Silberg, Esquire R. A. Capra, NRC ~

i D. G. Mcdonald, Jr., NRC

[

T. T. Martin, NRC l

P. R. Wilson, NRC

- P. I. McLean,- DNR J. H. Walter, PSC -

i f

(;. O n t r,

9205010221 920424 PDR ADOCK 05000317 R-PDR 3 l

9

~

D.

ODCM and Process Contml Plan (PCP) Changes One change was made to the ODCM during the second half of 1991. The change was j reviewed by POSRC and approved by the Plant General Manager, Calvert Cliffs Nucicar Power Plant, prior to implementation. The scope and basis for this char r is discussed in Appendix B.

In keeping with thc requirement of the Technical Specification 6.17, a copy of the change to the CCNPP ODCM is enclosed in Attach.nent 1.

Vertical lines in the right margin of the text denote the abm referenced change with accompanying change number.

No changes were made in the PCP in t ee second half of 1991.

E.

Radioactive Gaseous Efluent Monitoring Instrumentation The Unit 2 Main Vent IIcader Noble Gas effluent reonitor (2-RI.5415) was out of service for greater than 30 days during the second half of 1991. This notice is required by Technical Specification 3.3.3.9. This monitor was declared inoperable on Aegust 9, 1991 because of frequent RMS pump failures. The source of the failures was a blocked discharge line fitting but the source of the problem was not immediately l

identified despite extensive troubleshooting efforts. The RMS effluent monitor was restored to service on September 12,1991.

IV.

AVERAGE ENERGY Not Applicable.

V.

MEASilREMENTS AND APPROXIMATIONS AND TOTAL HADIOACTI\\TlY A.

Fission and Activation Gases 1.

Batch Releases Prior to each batch release of gas from a pressurized gas decay tank, a sample L

is collected and analyzed by pmma spectroscopy using a Ge detector for the i

principal gamma emitting noble gas radionuc! ides. The total activity released is based on the pressure / volume relationship (gas laws) of the tank.

Prior to and after each containment purge, a gas sample is collected and analyzed by gamma spectroscopy using a Ge detector for the principal gamma emitting noble gas radionuclides. The total actipty released is based on containment volume and purge rate. Activity buildup while purging is also considered.

2.

Continuous Releases t

l A gas sample is collected at least weekly from the main vents and analyzed by gamma spectroscopy using a Ge detector for the principal gamma emitting noble gas radionuchdes. The total activity released for the week is based on

- the total sample activity decay cor ected to the midpoint of the sample period multiplied by the main vent flow for the week.

L 4

3-TAllLE IC - REG GUIDE 1,21 (Cont.)

C ALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SE511-ANNUAL REPORT SECOND IIALF-1991 GASEOUS EFFLUENTS GROUND LEVEL REl EASES CONTINUOUS MJDE IIATCil h10DE 3RD 4TII 3RD 4Til

3. PARTICULATES UNITS QUARTER QUARTER QUARTER QUARTER Manganese

-54 Ci (2)

(2)

(1)

(1)

Iron

-59 Ci (2)

(2)

(1)

(1)

Cobalt

-58 Ci (2)

(2)

(1)

(1)

Cobalt

-60 Ci (2)

(2)

(1)

(1)

Zinc

-65 Ci (2)

(2)

(1)

(1)

Strontium

-89

- Ci (2)

(2)

(1)

(1) l Strontium

-90 Ci (2)

(2)

(1)

(1) l Molybdenum

-99 Ci (2)

(2)

(1)

(1)

Cesium

-134 Ci (2)

(;2)

(1)

(1)

Cesium

-137 Ci (2)

(2)

(1)

(1)

Cerium.

-141 Ci (2)

(2)

(1)

(1)

Cerium 144 Ci (2)

(2)

(1)

(1)

- Total For Period Ci (1)

(1)

NOTES TO TAllLE IC (1)

Iodines and particulates in batch releases are accounted for with the main vent continuous samplers when the release is made through the piant main vent.

(2)

Lcss than minimum detectable activity which meets the LLD requirements of Technical Specification Surveillance Requirement 4.11.2.1.2.

12

'l'ABLE 2A - REG GUIDE 1.21 CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL HEPORT SECONDllALF 1991 LIOUID EFFLUENTS SUMMATION OF ALL RELEASES 3RD 4Til EST. TOTAL A. FISSION AND ACTIVATION PRODUCTS UNITS QUARTER QUARTER ERHOR, %

1.

Total Release (not including tritium, gases, alpha)

Ci 5.87E-01 1.62E-01 3.30E+00 2.

Average diluted concentration during period uCi/mi 1.18E-08 7.71E-10 l

3.

Percent of Tech. Spee, limit (1) 8.45E-02 1.75E-04 4.

Percent of Tech Spec. limit (2) 4.25E-02 8.75E-02 5.

Percenuf Tech. Spec. limit (3) 5.59E-01 2.50E-02 6.

Percent of Tech. Spec. limit (4) 2.79E-01 L25E-02 IL TRITIUM 1.

Total Rele ase Ci 4.33E+02 4.52E+ 02 19.80E+00 2.

Average diluted concentration

~

durini, period.

uCi/ml 8.66E-06 2.15E-06 l

3.

Percent of applicablelimit(5) 2.89E-01 7.17E-02 l

C. DISSOLVED AND ENTRAINED GASES 1.

Total Release Ci 2.95E-02 1.76E-01 14.60E+00

2. ' Average diluted concentration dtiring period uCi/ml 5.95E-10 8.38E-10 l

t 13

TABLE 2A - REG GUlDE 1.21 (Cont.)

CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI. ANNUAL REPORT SECOND llALF-1991 LIOUID EFFLUENTS - SUMMATION OF ALL RELEASES 3RD 4TIl EST. TOTAL D. GROSS ALPIIA RADIOACTBTlY UNITS QUARTER QUARTER ERROR, %

1.

Total Release Ci 2.23E-05 8.35 E-05 i5.36E+01 E. VOLUME OF WASTE RELEASES (prior to dilution) liters 9.73E +06 3.15E+07 1.30E +00 l

F. VOLUME OF DILUTION WATER USED DURING PERIOD liters 5.00E+ 10 2.10E + 11 11.64E+01 l

l l

NOTES TO TABLE 2A (1)

Percent ofI.C.3 Quarterly Organ Dose Limit (10 mrem)

(2)

Percent ofI.C.3 Yearly Organ Dose Limit (20 mrem)

(3)-

Percent ofI.C.3 Quarterly Whole Body Dose Limit (3 mrem)

(4)

Pe cent ofI.C.3 Yeacly Whole Body Dose Limit (6 m.:m)

'(5)

Limit used is 3 x 10-3 uCi/ml (6)

Less than minimum detectable activity which meets the LLD requirements of Technical Specification Surveillance Requirement 4.11.1.1.1.

t t

14

T.

TAllLE 211. REG GUIDE 1.21 CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT SECOND llALF.1991 LIOUID EFFLUENTS CONTINUOUS MODE CATCH MODE 3RD 4TII 3RD 4TII NUCLIDES RELEASEI)

UNITS QUARTER QUARTER QUARTER QUARTER i

Sodium -

-24 Ci (1)

(1) 8.74E-05 (1)

Chromium

-51 Ci (1)

(1)

(1)

' 1.24 E-N Manganese

-54 Ci (1)

(1) 1.02E-03 1.92E-04 Cobalt

-57 Ci (1)

(1)

(1)

(1)

Cotialt

-58 Ci (1)

(1) 1.50E-02 7.35E-02 Iron

-59 Ci (1)

(1)

(1)

(1)

' Cobalt

-60 Ci (1)

(1) 8.47E-03 4.82E-03

..--. j Zinc

-65 Ci (1)

(1)

(1)

(1)

Strontium.

89 Ci (1)

(1) 3.28E-03 1.16E-03 l

Strontium

-90 Ci (1)

(1) 2.93E-04 2.12E-04 l

Strontium

-92 Ci (1)

(1)

(1)

(1)

Niobium

-95 Ci (1)

(1) 2.85E-04 1.78E-03 Niobium

-97 Ci (1)

(1) 1.41E-04 1.105-03 Zirconium

-95 Ci (1)

(1)

(1) 8.95E-M Molybdenum

-99 Ci (1)

(1,_

(1)

(1)

Technetium

-99m Ci

'(1)

(1) 5.72E-04 3.05E-04 Ruthenium

-106 Ci (1)

(1) -

(1)

(1)

Silver

-110m Ci (1)

(1) 5.82E-03 1.92E-03 Tin

-113 Ci (1)

(1, (1)

(1)

Antimony

-122 Ci (1)

(1) 3.71 E-05 6.04E-06 Antimony

-125 Ci (1)

(1) 1.39E-02 1.63E-05 Technetium

-132 Ci

.(1)

(1)

(1)

(1) 15

~

TAllLE 211 - REG GUIDE 1.21 (Cont.)

CAINERT CLIFFS NUCLEAR POWER PLANT EFFLUENTAND WASTE DISPOSAL SEMI ANNUAL REPORT SECOND IIALF-1991 LIOUID EFFIcUENTS CONTINUOUS A10DE IIATCII hlODE 3RD 4TII 3RD 4Til NUCLIDES RELEASED UNITS QUARTER QUARTER QUARTER QUARTER 3

- Iodine 131 Ci (1)

(1) 1.85E 1.71E-02 Iodine 132 Ci (1)

(1)

(1) 8.29E-06 Iodine 133 Ci (1)

(1) 1.82E-02 1.93E-03 Iodine.

-135 Ci (1)-

(1) 1.86E-04 (1)

- Cesium 134

' CI (1)

(1) 9.42E 1.89E-02

-Cesiun.

136-

- Ci (1)

(1)

(1) 1.12E-05 Cesium -

137 Ci (1)

(1) 4.06E-01 3.82E-02

--Barium

-140 Ci (1)

(1) 1.33E-03 (1)

{

Lanthanum -

-140 Ci (1)

(1) 1.67E-03

- 5.25E-04 Cerium -

-144 Ci (1) -

(1) 1.87E-04 (1)_

Tungsten

--187 Ci (1)

(1) 2.21 E (1)

Total For Period -

Ci (1)

(1)'

5.50E-01 1.44E-01 l.

. Xenon-131m Ci (1) __-

(1)

(1)

(1)

-Xenon-

-133-Ci (1)

-(1) 2.85E-02 1.18E !'

Xenon 133m

.Ci (1)-

(1)

_(1) 1.50E-03 '

-Xenon

-135-Ci (1)

(1) 9.46E 7.37E ___

. Xenon-

- - 135m -

Ci (1)

(1)

(1)

(1)-

Total For Period Ci-(1)

(1)

. 2.95E-02 1.76E-01 1

<~

16 T

w'

-+is m.

a t

_. - ~

4 w

TAllLE 2H - REG.fdIIDE 1.21 (Cont.)

CALVERT CLIFFS NUCLEAR Pt 'WER FLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT SECOND IIALF-1991

^

LIOUID EFFLUENTS NOTES TO TAllLE 211 (1)

Less than minimum detectable activity which meets tLe LLD requirements of Technical Specification Surveillance Requirement 4.11.1.1.1.

a w

d i

17 -

~.. - - -.

TAllLE 3A CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT SECOND1IALF 1991 SOLID WASTE AND IRRADIATED FUEL SIIIPMENTS A. - SOLID WASTE SIIIPPED_ OFFSITE FOR IlURIAL OR DISPOSAL (NOT IRRADIATED FUEL) 6 MONT11 EST. TOTAL

1. Type of Waste UNITS PERIOD ERROR %

3 a.

Dewatered spent resin m

6.81 E +00 Ci 5.00E+01 i2.00E+01 l

b.

Dry Compressible Waste (Burial) 3 m

7.01E+01 Contaminated Equipruent, etc.

Cj 1.32E+01 5.00E+01 (Prior to Compaction) m 5.40E +02 3

c.

Irradiated Components, m

6.20E-01 Control Rods, etc.

Ci 4.32E+03 5.00E+01 d.

Other (CVCS Filters) 3 m

Ci i2.00E+01 2.

Estimate of Major Nuclide2 (By Type of Waste - Only nuclides > l % are reported) a.

Iron

-55 4.55E+00 %

- Cobalt

-58 1.55E+00 %

Cobalt

-60 2.95E+00 %

Nickel

-63 1.06E+01 %

Antimony

-125 1.10E+00 %

Cesium

-134 L96E+01 %

Cesium

-137 5.56E+01 %

b.

Carbon

-14 2.05E+00 %

Chromium

-51 9.62E+00 %

Iron

-55 3 #5E+01 %

Cobalt

-53 1.52E+00 %

Cobalt

-60 1.01E+01 ~5 Nickel

-63 1.31E+01 %

Ruthenium

-106 2.52E+00 %

Silver

-110 1.41 E +00 %

Antimony

-125 4.75E+00 %

Cesium

-134 2.70E+00 %

Cesium

-137 1.07E+01 %

c.

Manganese

-54 1.20E+00 %

Iron

-55 5.66E+01 %

Cobalt 3.80E+01 %

Nickel

-63 4.00E+00 %

18 z.

APPENDIX 11

SUMMARY

OF CIIANGES TO TIIE CCNPP ODCM SECOND IIALF 1991 u

CIIANGES TO TIIE CCNPP ODCM IN SECOND IIALF 1991

SUMMARY

AND IIASIS The Calvert Cliffs Offsite Dase Cale lation Manual (ODCM) is contained in the Chemistry Procedure CP.607. Chnages to this document are controlled through 6e normal procedure change review and. approval process.

This process meets -the requirements of CCNPP Technical Specification 6.17.

One change was made to the ODCM during the second ha'f of the year 1991. The change was l reviewed by the Plant Operations and Safety Review Committee (POSRC) and approved by the

- Plant General Manager, Calvert Cliffs Nuclear Power Plant, prior to implementation. Change bars are provided in the right margin of the ODCM text to identify the changes made.

l The change was reviewed and approved on September 16,1991, and designated as change 91-155 l This change was made to describe an erwironmental sampling location in better detail.

i l

l

[~

i E

B-1 1_

.