TABLE 1A - REG GUIDE 1.21 CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT FIRST HALF - 1988 3

GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES i

IST 2ND EST. TOTAL A.

FISSION AND ACTIVATION GASES UNITS OUARTER OUARTER ERROR.%

1.

Total Release Ci 2.63E+03 1.63E+03 2.15E+01 2.

Averaae release rate for oeriod uCi/sec 3.35E+02 2.07E+02 3.

Percent of tech.soec. limit (1) 4.76E-02 3.77E-02 4.

Percent of tech.soec. limit (2) 1.90E-02 1.79E-02 5.

Percent of tech.soec. limit (3) 7.02E-01 5.32E-01 6.

Percent of tech. spec. limit (4) 3.51E-01 2.66E-01 7.

Percent of tech.soec. limit (5) 9.98E-01 7.77E-01 8.

Percent of tech.soec. limit (6) 4.99E-01 3.88E-01 B.

10 DINES 1.

Total Iodine - 131 Ci 4.77E-02 5.55E-02 1.84E+01 2.

Averaae release rate for period uCi/sec 6.07E-03 7.06E-03 3.

Percent of tech.soec. limit (7) 1.44E-02 1.68E-02 4.

Percent of tech.soec. limit (8) 1.54E+00 1.79E+00 5.

Percent of tech. spec. limit (9) 7.68E-01 8.95E-01 C,

PARTICtJLATES 1.

Particulate with half lives areater than 8 days C i ___

3.63E,-05 1.16E-02 1.84E+01 j

2.

Averaae release rate for oeriod utt/sec 4 32f-06_

l.48E 13 3. Perc9ap of tech.soec. limit (7)

_Js10E-05 3.52E-03 1

4.

Percent of tech soec. limit (0) l.1LE-03 2 73E-0L i

5.

Percent of tech.soec. limit (9) 5.84E-04 1.86E-01 6.

Gross alpha radioactivity Ci

<3.46E-05

<1.01E-05 l

1 hop 9

y#

so

r-TABLE 1A - REG GUIDE 1.21'(Cont,)

CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT FIRST HALF - 1988 GASEQUS EFFLUENTS - SUMMATION OF ALL RELEASES IST 2ND EST. TOTAL D.

TRITIUM UNITS OVARTER OVARTER ERROR.%

1.

Total Release Ci 5.66E-01 2.04E+00 2.18E+01 2.

Averaae release rate for oeriod UCi/sec 7.20E-02 2.59E-01 NOTES TO TABLE 1A (1)

Percent of I. A.1 whole body dose rate limit (500 mrem / year)

(2)

Percent of I.A.1 skin dose rate limit (3000 mrem / year)

(3)

Percent of I.A.3 gamma quarterly dose limit (10 mrad)

(4)

Percent of I.A.3 gamma yearly dose limit (20 mrad)

(5)

Percent of I.A.3 beta quarterly dose limit (20 mrad)

(6)

Percent of I. A.3~ beta yearly dose limit (40 mrad)

(7)

Percent of I.B.1 organ dose limit (1500 mrem / year)

(8)

Percent of I.B.3 quarterly dose limit (15 mrem)

(9)

Percent of I.B.3 yearly dose limit (30 mrem) j j

l l

10 3

i

J TABLE 2A - REG GUIDE 1.21 CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT FIRST HALF - 1980 LIOUID EFFLUENTS - SUMMATION OF ALL RELEASES IST 2ND EST. TOTAL A.

FISSION AND ACTIVATION PRODUCTS UNITS OVARTER OVARTER ERROR.%

1.

Total Release (not including tritium.aases. aloha)

Ci 7.40E-01 9.64E-01 2.16E+01 2.

Average diluted concentration durina Deriod uCi/ml 1.24E-09 1.52E-09 3.

Percent of tech.soec. limit (1) 4.60E-01 2.37E+00 4.

Percent of tech.soec. limit (2) 2.30E-01 1.18E+00 5.

Percent of tech.soec. limit (3) 6.28E-01 2.61E-01 6.

Percent of tech.soec. limit (4) 3.14E-01 1.30E-01 B.

TRITIUM 1.

Total Release Ci 1.40E+02 6.99E+01 1.81E+01 2.

Average diluted concentration durina period uCi/ml 2.35E-07 1.17E-07 3.

Percent of aoolicable limit (5) 7.83E-03 3.90E-03 C.

DISSOLVED AND ENTRAINED GASES 1.

Total Release Ci 9.48E-02 1.48E-01 2.00E+01 2.

Average diluted concentration durina period uCi/ml 1.59E-10 2.49E-10 4

a 13

TABLE 2A - REG GUIDE 1.21 (Cont.)

CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT FIRST HALF --1988 LIOUID EFFLUENTS - SUMMATION OF ALL RELEASES IST 2ND EST. TOTAL D.

GROSS ALPHA RADI0 ACTIVITY UNITS OVARTER OUARTER ERROR.%

l ~. Total Release Ci

<8.01E-04

<2.42E-04 3.00E+00 E.

VOLUME OF WASTE RELEASES forior to dilution) liters 5.87E+06 4.68E+06 3.00E+00 F.

VOLUME OF DILUTION WATER USED DURING PERIOD liters 5.95E+11 5.95E+11 1.40E+01 NOTES TO TABLE 2A (1)

Percent of I.C.3 Quarterly Organ Dose Limit (10 mrem)

(2)

Percent of I.C.3 Yearly Organ Dose Limit (20 mrem)

(3)

Percent of I.C.3 Quarterly Whole Body Dose Limit (3 mrem)-

(4)

Percent of I.C.3 Yearly Whole Body Dose Limit (6 mrem) l (5)

Limit used is 3 x 10-3 uCi/ml u

14