1993 Bg&E Calvert Cliffs Nuclear Power Plant Rept on Number of Personnel & Man-Rem by Work & Job Functions
ML20064C994
Person / Time
Site: Calvert Cliffs  
Issue date: 12/31/1993
From: Cruse C
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9403110004
Download: ML20064C994 (2)


Text

.

w B A LTIMORE l

GAS AND ELECTRIC

~

CALVERT CLIFFS NUCLEAR POWER PLANT 1650 CALVERT CLIFFS PARKWAY

-I I

l CHARLES H CRUSE PL ANT GE NEHAL mar 4-Cif H CALVERT CLIFFS February 28,1994 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 Annual Personnel Exposure Report Technical Specification 6.9.1.5.a Per the requirements of Technical Specification 6.9.1.5.a, we hereby submit the attached Personnel Exposure Report. This report contains the tabulation of the number of station, utility, and other personnel receiving exposures greater than 100 mrem for 1993 and their associated man-rem exposure according to work and job functions.

Should you have any questions regarding this matter, we will be pleased to discuss them with you.

Very truly yours,

/

h/ a

,s-

-pse, ClIC/CDS/bjd Attachment cc:

D. A. Brune, Esquire J. E. Silberg, Esquire R. A. Capra, NRC q

D. G. Mcdonald, Jr., N RC T. T. Martin, NRC P. R. Wilson, NRC O8 1l9 R. I. Meixan, DNR J.11. Walter, PSC i

/

I '

f 9403110004 931231 PDR ADOCK 05000317 4

R PDR i

- - ~.

l

~

t 1993 BG&E Calvert Cliffs Nuclear Power Plant Report on Number of Personnel and Man Rem by Work & Job Function l

No. of personnel (> 100 mrem) l Total Man-Rem l

Station Utility Contractor Station Utility Contractor Work & Job Function Employees Employees Work ers Employees Employees Workers

" Reactor Operations & Surveillance Maintenance Personnel 3

0 0

0.370 0.000 0.000 Operating Personnel 53 0

0 9.927 0.000 0.000 Health Physics Personnel 3

0 0

0.440 0.000 0.000 Supervisory Personnel 0

0 0

0.000 0.000 0.000 Engineering Personnel 0

O O

O.000 0.000 0.000 Routine Maintenance Maintenance Personnel 40 7

110 7.704 0.915 31.556 Operating Personnel 5

0 1

. 0.864 0.000 0.152 Health Physics Personnel 10 0

0 1.654 0.000 1.309 Supervisory Personnel 1

0 1

0.110 0.000 0.153 Enginnenng Personnel 8

1 0

1.574 0.218 0.000 Inservice Inspection Maintenenen Personnel 2

2 45 0.334 0.261 8.333 Operating Personnel 1

O O

O.344 0.000 0.000 Health Physics Personnel 23 0

85 7.609 0.000 25.555 Supervisory Personnel 0

0 3

0.000 0.000 0.370 Engineenng Personnel 4

0 0

1.045 0.000 0.000 Special Maintenance Maintenance Personnel 63 15 221 16.227 4.195 78.403 Operating Personnel 9

0 3

5.918 0.000 0.923 Health Physics Personnel 14 0

45 4.097 0.000 12.911 Supervisory Personnel 1

0 1

0.595 0.000 0.110 Engineering Personnel 3

0 2

1.261 0.000 0.877 Waste Processing Mmntenance Personnel 3

1 17 0.538 0.151 3.330 i

Operating Personnel 1

1 4

0.102 0.138 0.939 Health Physics Personnel 18 1

43 6.791 0.338 15.701 Supervisory Personnel O

O O

O.000 0.000 0.000 Enoineenng Personnel O

O O

O.000 0.000 0.000 Retualing Maintenance Personnel 27 8

75 7.000 1.149 39.924 Operating Personnel 1

0 3

0.131 0.000 2.161 Health Physics Personnel 9

0 42 2.664 0.000 14.076 Supervtsory Personnel 1

0 4

0.121 0.000 2.064 Engineenng Personnel 1

0 2

0.143 0.000 0.806 Total ISum of 6 Work Functions > 100 mrem)

Maintenance Personnel 128 16 390 44.449 7.097 185.033 Operating Personnel 69 1

13 19.072 0.141 4.753 Health Physics Personnel 52 1

120 26.978 0.438 78.100 Supervisory Personnel 5

0 11 1.376 0.000 3.129 Engineering Personnel 27 1

4 6.433 0.299 1.886 l Grand Total l

281 l

19 l

538 l

98.308 l

7.975 l 272.900 l l Total Man Rem of all Workers' l

l 110.826 l 8.756 l 287.576 l

  • Totals include exposure of individuals with less than 100 miem.

.