TABLE 1A - REG GUIDE 1.21 4
CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT FIRST HALF - 1991
~
SASLOUS EFFLUENTS - SUMMATJON 0E AR RELEASLS
=
IST 2hD EST. TOTAL A.
FISSION AND ACTIVATION GASES UNITS QUARTER QUARTER ERROR,%
1.
Total Release Ci 7.07E+02 6.95E+02 16.20E+00 2.
Average release rate for period uCi/sec 8.99E+01 8.E4E401 3.
Percent of tech. spec. limit (1) 2.60E-03 3.20E-02 4.
Percent of tech. spec. limit (2) l.07E-03 1.27E-03 5.
Percent of tech. spec. limit (3) 2.10E-01 1.90E-01 6.
Percent of tech. spec. limit (4) 1.05E-01 9.50E-02 7.
Percent of tech. spec. limit (5) 2.70E-01 1.32E 02 8.
Percent of tech. spec. limit (6) 1.35E-01 6.60E-02
~'
B.
10 DINES l.
Total lodine - 131 C1 4.79E-03 1.75E-02 6.50E+00 2.
Average release rate for period uCi/sec 6.09E-04 2.22E-03 3.
Percent of tech. spec. limit (7) 5.82E-Od 2.UUE-03 4.
Percent of tech. spec. limit (8) 3.20E-Oi 6.27E-01 5.
Percent of tech. spec. limit (9) 1.COE-01 3.13E-01 C.
PARTICULATES 1.
Particulates with half lives greater than 8 days Ci 4.97E-07 2.83E-07 2.80E+01 2.
Average release rate for period uti/sec 6.33E-08 3.60E-08 3.
Percent of tech spec.11mit(7) 9.38E-07 5.33E-07 4.
Percent of tech. spec. limit (8) 9.15E-03 5.2]E-03 5.
Percent of tecn. spec. limit (9) 4.58E-03 2.61E-03 l
l 6.
Gross alpha radioactivity Ci (10)
(10) 6.54E+01 l
l l
l
,d[0$hh [hbt 7 l
n m
IABLE 10 -REG _0010L12EL(CsntJ CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMs ANNUAL REPORT FIRST HALF - 1991 DME005 EFFLUENTS - GROURQ_LEYEL RELEME) 0 CONTINU0US MODE BATCH riODE IST 2ND IST 2ND L 1 6 M lCll L A I E S UNITS QUARIER QUARIER OUARTER QUARIEL.,
Manaanese 54 1
(2)
(2)
(1)
(1)
-59
_ St (2)
(2)
(1) _
(1)
-38 Ci (1)
(2)
(1)
(1)
Cohalt
-60 Ci (2)
(1)
(J )
(1)
.65 Ci (2)
(2) 11)_
(lj Strontium
-89 Ci (2)
(Z) 11)
(1)
St ront ium
-90 Ci 4.97E-07
- 2. 81[_0]_
_(1)
(1) figlvbdenum -99 CL_
J2)
(2)
(IL (1)
-134 Ci (2)
(21 (1)
(1)
-137 Ci (2)
(2)
(1)
(1)
-141 Ci (2)
(2)
(1)
(1)
-144 Li (2)
_ _{2 )
(1)
(1)
ToLal For Period Ci 4.97E-07 2.H3E-07 (1)
(1)
(1)
Iodines and particulates in batch releases are accounted for with the main vent continuous samplers when the release is made through the plant main vent.
l (2) Less than minimum detectable activity which meets the LLD require: 'ts of Technical Specification Surveillance Requirement 4.11.2.1.2.
l 13 l
t
.. - -. ~. -.
i
+
IABLE 2A - REG GUIDE 1.21 CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SENI-ANNUAL REPORT FIRST HALF - 1991 LIQUID EFFLUENTS - SUMMATLON OF ALL_RELE&i[i IST 2ND EST. TOTAL
- A.
FISSION AND ACTIVATION PRODUCTS UNITS OVARTER 00ARTER ERROR.%
1; Total Release (not-including tritium. cases. alpha)
- (i 5.40E-01 3.05E-01___
l.03E+01
'2.
Average diluted concentration
____dyrina period uti/ml 4.43E-09 2.04E-09 3.- Percent of tech.soec.limitfl) 1.27E+00 3.90E-01 4.
Percent QL_ lech.soec. limit (2) 6.35E-01 1.95E 01 5.
Percent of tech.soec. limit (3) 3.00F-01 1.66E 01 l6; Percent of tech.soec. limit (4) 1.50E-01 8.30E-02 Rf TRITIUN 1.
Total Release Ci 5.24E+01 7.94E+01 1.04E+01 _
- 2. ~ Average diluted concentration durina period uCi/ml 4.30E-07 5.29E-07 3
Percent of anolicable limitf 5) 1.43E-02 1.76E-02 C. 2 DISSOLVED 'AND ENTRAINELGASES J.
Total Release-Ci 2.44E-01 1.71E+01 4.80E400 2.
Average diluted concentration durino~ period uCi/ml 2.01E-09 1.14E-07 a
14
.-. - - - -.. ~ _ -
- - -. ~ - - - - - - -
c.
TABLE 2B - REG GUIEE 1.21 CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SENI-ANNUAL REPORT l
FIRST HALF - 1991 I
LLQUID EFFLt)INI.$
i CONTINUOUS MODE BATCH MODE IST 2ND IST 2ND NUCLIDES: RELEASED UNITS 00ARTER OUARTER QUARTER 00ARTER Sodium
-24 Ci-(1)
(1)
..txtLE-04 (1)
-51 Ci (1)
(1) laf0E-02 (1)
Manaanese
-54 Ci (1)
(1) 1/~ 39 3 2.llE 03 Cobal t
-57 Ci (1)
(1)
( 1.1 (1)
-58 Ci 5.72E-04 (1) 3.08E-02 2.57E Iron
-59 C1 (1)
(1)
(1)
(1)
-60 Ci (11__.
(1) 1.26E-02 7.07E-03 Zine
-65 Ci (1)
(1) il)
(1)
-89 Ci (1)
(1)
(1) 3.20E-03
-Strontium
-90 Ci (1)
.,( 1 )
3.95E-04 4.29E-04
-92
-Ci (1)
(1)
(1)
(1)
-95 Ci
_111 (1) 2.66E-03 4.30E-04 Niobium
-97 Ci (1)
(1)
_ jl lgf-03 6.51E-03 Zirconium
-95 Ci (1)
(1) 2.46E-03 (1) l Molybdenum
-99 Ci (1)
(1)
(1)
(1)
-99m Ci (1)
._Lll._
4.37E-04 1.63E Ruthenium
-106 Ci f il_
(1) 1.22E-04 8.77E-05 l
-Il0m Ci 3.73E-03 (1)-
4.71E-02 1.48E-02 Tin
-113 Ci (1)
(1) 1.17E-04 (1)
-122 C.
5.51E-n3 (1) 2.80E-04 2.71E-05 l-Antimony
-125 Ci (1)
(1) 1.33E-01 5.14E Technetium
-132 Ci (1)
(J )
2.85E-06 (1) l_
16 L
l'
~
IABLE_2D - REG GUIDE IdLRgnt_d CALVERT CLIFFS NUCLEAR POWER "LANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT FIRST HALF - 1991 L10VID EFFLUENTS CONTINUOUS MODE BATCH N0DE IST 2ND IST 2ND WC11 DES RELEASED UNilS OVARTER OVARTIR OVARTER QUART _ER lodine
- L11 Ci (1)
{li L_43 E-02 42L.02 ladine..
-133 Ci (1)
(1) 8.44E-03 2.5BE-03 Jpjjjat
-135 Ci.
(1)
(1)
(1)
(11 Cuium
-134 Ci 2J 2 E-03 (1) 4.20E-02 2.49E-02
[tsium
-136 Ci (1)
(1) 6.55E-05 7.17E-04
[glium
-137 Ci Q_,.99 E - 03 (1)
(1)
(1)
Earium
-140 Ci (1)
(1)
(1) 1.76E 03 Lanthanum
-140 C1 (1)
(1) 7.44E-04 5.66E-03 Cerium
-141 Ci (1)
(1)
(1)
(1)
[.erium
-144 C1 (1)
(1) 5.DE_-03 idsf-0J__
Iunasten
-187 C1 (1)
(1) 5.85L-04 _
(1)
Total For Period Ci
' 13E-02 (1) 4.85E-01 2.60E-01 Yenon
-131m Ci (1)
_(1)
(1)
(1)
-133 Ci 4 60E-03 (1) 2.33E-01 1.71[191__
-133m Ci (11 (1) 3.76E-0L 2.01E_R3 Xenon
-135 Ci (1)
(1) 2.24E-03 3.35E-0_4 Xenon
-135m Ci (1)
(1)
(1)
(1)
Total For Period Ci 4.60E-03 (1) 2.39E-01 1.71E+01 (1) Less than minimum detectable activity which meets the LLD requirements of Technical Specification Surveillance Requirement 4.11.1.1.1.
l i
17 l
IABLEJa CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT FIRST HALF - 1991 IQLID WASTE AND IRBADLAIED FUfLS1{1Ptfjll$
b.
SOLID WASTE SHlffEQ_Qf15]lE_f9!LSUAIAL CR DlSlqSAL[MQLl!L8AQlAl[D FUEU 6 MONTH EST. TOTAL 1.
Type of vaste UNils PERLOD ERBQP%
3 a.
Dewatered spent resin m
9.93E400 Ci 9.76E+01 2.00E401 3
b.
Dry Compressible Waste (Burial) m 7.22E+01 Contaminated Equipment, etc.
Cj 2.36E401 5.00E+01 (Prior to Compaction) m 2.01E+02 3
c.
Irradiated Components, m
Control Rods, etc.
Ci 5.00Et01 3
d.
Other (CVCS Filters) m Ci 2.00E+01 2.
Estimate of Major Nuclides (By Type of Waste)*
a.
-55 4.50E400 %
-58 1.41E+01 %
-60 4.30E+00 %
-63 2.16E+01 %
-125 1.27E+00 %
-134 1.23E+01 %
-137 3.82E+01 %
b.
CL con
-14 1.33E+00 %
-55
' 94E+01 %
-58 2.08E+00 %
-60 1.21Et01 %
-106 1.42E400 %
-63 2.37E+01 %
-134 2.92E+00 %
-137 1.llE401 %
-125 1.74E+00 %
- Only nuclides greater than 1% are reported 18