ASME Section 11 Weld Examination Program for Facility: Inservice Insp Program
ML19329A920
Person / Time
Site: Davis Besse 
Issue date: 11/22/1977
From:
TOLEDO EDISON CO.
To:
References
PROC-771122, TAC-10985, NUDOCS 8001150816
Download: ML19329A920 (180)


Text

{{#Wiki_filter:_ _ _ _ _ _ _ _. - ~ ~ -3 g - - e ,f' y ' 9 .. i,, m, s < a A. e, .= o .*y,.g

,. ~
-

i ? + .y a y u 3 - :. _p r. a C: ' l ~

  1. ~ -. jy
  • y.

E g t r -.. as y r ' es .. y ~ s .y-i,

  • g y

g .f,= 1 L , e ? - N i ~- k. ,i r ~ _g. ^ ' .1. T. r.. e j 1. g V ',. = M e. r ~ e A ,.? ~' r ' '. ~. .. ~ '.: ~ a. + Jg. { Q

  • w_~;

q. t>- 'I_. s e. s + + =, p-5- + ^ ?. r., ,. 3 ...[ 4 x S' 'A \\ s. 4 e i 3 ~. 4 m m-m n na ? k .g _ g ~ THE ATTACHED F LES AHE JtF.CI A, RECORDS OF THE i,.. - DIVISION OF DOCUMENT CONTROL. THEY HAVE BEEN CHARGED TO YOU FOR A LIMITED TIME PERIOD AND ' ' m. 4 MUST BE RETURNED TO THE RECORDS F ACILITY ? BRANCH 016. PLEASE DO NOT SEND DOCUMENTS r CHARGED OUT THROUGH THE MAIL. REMGVAL OF ANY PAGE(S) FROM DOCUMENT FOR REPRODUCTION MUST E [.- '4-- + - BE REFERRED TO FILE PERSONNEL. (.( 9- ~ i j ',

az_,

N . p-w M DEADLINE RETURN DATE 7~- p, s 3.., s. 96. L 2. v [ ..'....g..- .s . en .,~ a s, W o + - e i t RECORDS F ACILITY BRANCH 1

TECO/ DAVIS-BESSE/ UNIT 1 ATTACHMENT A ( ASME SECTION XI WELD EXAMINATION PROGRAM FOR DAVIS-BESSE, UNIT 1 A. The Weld Examination Program for Class 2 and 3 systems shall be conducted in accordance wi'h Subsections IWC and IWD of Section XI of the 1974 t Edition of the ASME Boiler and Pressure Vessel Code-through Summer 1975 Addenda, except for specific relief requested in accordance with 10 CFR 50.55a (g) (5,' 'iii), which is identified in Attachment B. B. The period for which the Weld Examination Program is applicable, is the 40-month period commencing with commercial operation. C. The Weld Testing Program was developed employing the classification guidelines contained in 10 CFR 50.2(v) for Quality Group A and Regulatory Guide 1.26, Revision 2, for Quality Groups B and C. (Quality Group A is the same as ASME Class 1, Group B is 2, and Group C is 3.) D. Table 1, Welds Examined in Accordance with Code Requirements, identifies the following for each applicable system: 1. Class - ASME Piping Classification. 2. ISO NO. - Isometric Fiping Drawing Number. e.g., PM-233F PM - Prefix denoting isometric drawing 233 - ISO is found on P&ID M-033 F - Denotes the identification of the drawing in a series of ISO's from P&ID M-033. 3. P&ID No. - Piping and Instrumentation Drawing Number. 4. Line No. - Identifier of pipe run to show size, use, pressure rating, material'and code to which the piping is designed. e.g., 3"-HBB-4 l 3" - Denotes 3 inch nominal pipe diameter HBB Denotes use of the line j 5., Spool Piece No. - Number identifying a particular portion of piping. e.g., 33B-HBB-5-6 33B Contained on ISO No. PM-233B HBB Line number HBB-5 6 Spool Piece No. 6 in a series of spools all making up line HBB-5 ~. *. ; - % t,.,. 6. Design Operating Pressure - PSIG. 7 0 * r. - ygg: L A-1

~

~

TECO/ DAVIS-BErsE/ UNIT 1 ATTACHMENT C -f CONTENTS FIGURE 1 Weld Exmination Program Index and Matrix for Tables 1 & 2. FIGURE 2 Code for Column "Y" of Table 2 Identifying the Reason an Examina-tion Has Been Determined to be Impractical. FIGURE 3 Code for Abbreviations Used in Column "Z" of Table 2 Identifying the "In Lieu Of" Examination to be performed. FIGURE 4 - Summary of Weld and Support E: minations for Class 2 Systems Tables 1 and 2 as Identified in Figure 1. C-1

TECO/ DAVIS-BESSE/ UNIT 1 FIGURE 1 WELD EXAMINATION PROGRAM INDEX AND MATRIX FOR TABLES 1 & 2 SYSTEM ISO NO. T-1 T-2 r MAIN STEAM (PEN-40) PM 203A 3 1 MAIN STEAM (PEN-39) PM 203B 3 1 MAIN STEAM PM 203J 2 7 AUXILIARY FEEDWATER PM 206F 3 1 STEAM GENERATOR DRAINS PM 207A 1 STEAM GENERATOR DRAINS PM 207B 1 MAIN FEEDWATER PM 207C 3 1 MAKE-UP WATER TREATMENT PM 210E 1 MAKE-UP WATER TREATMENT PM 210H 1 HYDROGEN DILUTION PM 229 2 4 PURIFICATION - R.C. LETDOWN PM 231A 2 MAKE-UP AND PURIFICATION PM 231B 1 MAKE-UP AND PURIFICATION PM 231C 1 MAKE-UP AND PURIFICATION PM 231D 2 EMERGENCY CORE COOLING PM 233A 1 EMERGENCY CORE COOLING PM 233B 2 11 DECAY HEAT REMOVAL PM 233C 2 5 HIGH PRESSURE INJECTION PM 233D 3 HIGH PRESSURE INJECTION PM 233E 2 LOW PRESSURE INJECTION PM 233F 6 20 REFUELING CANAL AND IN CORE TANK FILL & DRAIN PM 233G 1 LOV PRESSURE INJECTION - CORE FIDODING PM 234A 3 1 CONTAINMENT SPRAY PM 234B 3 CONTAINMENT SPRAY PM 234C 2 6 CONTAINMENT SPRAY PM 234D 1 5 SPENT FUEL POOL COOLING PM 235A 2 SPENT FUEL POOL COOLING PM 235B 1 COMPONENT COOLING PM 236D 1 COMPONENT COOLING WATER PM 236E 2 CCAPONENT COOLING WATER PM 236F 8 .<EACTOR COOLANT DRAIN PM 240A 1 PRESSURIZER QUENCH TANK CIRCULATION PM 240B 1 REACTOR COOLANT DRAIN & GAS RADIATION WASTE PM 240C 1 CONTAINMENT BUILDING VENTILATION PM 240D 1 SERVICE WATER PM 241C 1 SERVICE WATER PM 241D 1 SERVICE WATER PM 241E 1 SERVICE WATER PM 241F 1 1 SERVICE WATER PM 241G 1 LIQUID RADWASTE PM 246A 1 MAIN STEAM AND REHEAT NA 1 STEAM GENERATOR, SECONDARY NA 1 STATION AND INSTRUMENT AIR NA 1 NITROGEN SUPPLY NA 1 CONTAINMENT AND PENETRATION ROOMS NA 1 1 REACTOR COOLANT NA 1 MAKE-UP AND PURIFICATION NA 1 DECAY HEAT REMOVAL SYSTEM AND EMERGENCY CORE COOLING NA 1 i EMERGENCY CORE COOLING SYSTEM CONTAINMENT SPRAY & CORE FLOODING NA 1 t CLEAN LIQUID RADIOACTIVE WASTE NA 1 REACTOR COOLANT SYSTEM DETAILS NA 1 1 REACTOR COOLANT PUMP AND MOTOR NA 1 C-2

TECO/ DAVIS-BESSE/ UNIT 1 ATTACHMENT A 7. Design Operating Temperature 0F. 8. Weld Number - The identification number of the weld under considera-tion. 9. Support Number - The identification number of the support under con-sideration. 10. Code Section Allowing Exemption - Portion of Section IWC allowing exemption from testing in accordance with the requirements of IWC-1000. 11. Pipe Data a. Material - ASME material and type codes. b. Size - Nominal pipe size. c. Thickness - Pipe wall thickness. 12. Method of Inspection - Lists applicable examination category / categories from Table IWC-2520 which are requitad in addition to the requirements of IWC-5000. "HY-VIS" denotes that there is no examin-ation in addition to the requirement of IWC-5000. For those examination categories listed in Table IWC-2520, the test methods specified in Table IWC-2600 will be performed. 13. Stress Data Points - Stress data points pertaining to pipe break analysis, where applicable. 14. Remarks - Any additional explanatory entires. E. The following components will be inspected per the Code, unless specific relief is requested for any of the examinations stated in the Code. 1. Pressure Vessels e.g., C-A, C-B, C-C and C-D 2. Pumps e.g., C-F and C-G, C-D, C-E-1 and C-E-2 3. Valves e.g., C-F and C-G, C-D, C-E-1 and C-E-2 F. All Class 3 welds and supports will be inspected to the requirements of Article IWD-5000 of the Code. The examination shall be conducted to the extent practicable within the limitations of the component, or system portion, design and geometry. A-2

TECO/ DAVIS-BESSE/ UNIT 1 ATTACHMENT B WELD AND SUPPORT EXAMINATION REQUIREMENTS OF THE ASME CODE SECTION XI DETERMINED TO BE IMPRACTICAL Table 2 of Attachment C identifies the welds and supports for which relief from the examination requirements of Subsection IWC of Section XI of the 1974 Summer Edition of the ASME Boiler and Pressure Vessel Code, through the Summer 1975 Addenda, is requested in accordance with 10 CFR 50.55a(g) (5) (iii). Table 2 identifies the following information: 1. Clacs - Piping classification in accordance with Regulatory Guide 1.26, Revision 2, for Quality Groups B and C. 2. ISO ho. - Isometric Piping Drawing Number. 3. P&ID No. - Piping and Instrumentation Drawing Number. 4. Line Number - Identifier of pipe run to show size and use. 5. Spool Piece Number - Number identifying a particular portion of piping. 6. Weld Number - The identification number of the weld under considera-tion. 7. Support Number - The identification number of the support under consideration. 8. Material - ASME material and type codes. 9. Size - Nominal _ pipe size. 10. Thickness - Pipe wall thickness, 11. Stress Data Points - Stress data p91nts pertaining to pipe break analysis, where applicable. 1 12. System Function - A brief description of the function of the line ) within the system. J 13. Column "X" - Identifies the method of inspection that has been deter-mined to be impractical. j 14. Column "Y" - Identifies the basis for exception to the method of inspection listed in Column "X". The exception codes are listed on 1 Figure 2. ) 15. Column "Z" - Identifies the examination to be performed in lieu of the method of inspection listed in Column "X" and an explanation.of the exemption, if needed. Examination abbreviations are listed on Figure 3. B-1

TECO/ DAVIS-BESSE/ UNIT 1 FIGURE 2 CODE FOR COLUMN "Y" OF TABLE 2 IDENTIFYING EXAMINATION TO WHICH EXCEPTION IS BEING TAKEN s EX 1 Exempt, insufficient clearance for volumetric or surface inspection. EX 2 Exempt, insufficient clearrace for volumetric inspection, but sufficient clearance for surface inspection. EX 3 Exempt weld due to physical inaccessibility (height, location). EX 4 Exempt weld due to NRC criteria, Standard Review Plan, MEB.3-1, p7ragraph B.2.e, footnote 6, (page 3.6.2-14). System qualifies as a moderate-energy fluid system, since the time that it operates as a high-energy fluid system is about 2% of the time that is operates as a moderate-energy fluid system. EX 5 Exemption due to radiation in excess of 1000 mrem /hr. EX 6 Exemption due to postulated pipe break criteria per MEB 3-1. EX 7 Exemption from hydrostatic tispection due to open line. EX 8 Exempt from volumetric inspection due to insufficient wall thickness (<0.3125" = 5/16"). e ~ C-3

TECO/ DAVIS-BESSE/ UNIT 1 FIGURE 3 CODE FOR ABBREVIATIONS USED IN COLUMN "Z" OF TABLE 2 w' IDENTIFYING THE "IN LIEU OF" EXAMINATION TO BE PERFORMED SURFACE Surface Examination. VOLUMETRIC Volumetric Examination. VISUAL l Visual Examination during hydrostatic pressure test for circumferential and longitudinal pipe welds; visual examination of support integrity for pipe supports. No in lieu of exarination to be performed. e a r \\, - C-4

TECO/ DAVIS-BESSE/ UNIT 1 FIGURE 4

SUMMARY

OF WELD AND SUPPORT EXAMINATIONS FOR CLASS 2 SYSTEMS HY/VIS C-G SURFACE C-E-1. C-E-2 3308 351 395 136 262 l (1) Welds requiring visual examination during hydrostatic testing only. (2) Welds which may be given a volumetric examination. (3) Welds which may be given a surface examination. (4) Integrally-welded supports given a surface examination. (5) Support components given a visual examination. 6 i i C-5 l

TECO/ DAVIS., ESSE / UNIT 1 WELD

SUMMARY

SHEET - TABLE 1 SYSTEM MAIN STEAM (PEN 40) CLASS 2 . ISO NO. PM 203A,REV.liFAID NO. M-007, REV. 20 FAGE 1 OF 3 o CODE W SECTION ME7110D $z ALLOWING PIPE DATA OP 22 $ 2 EXEMPTION INSPECTION STRESS LINE SPOOL PIECE 3 W 3g WELD SUPPORT OR NRC SIZE '1113CKNESh (TABLE DATA NUMisER NUMBER Q a. QO NUMBER NUMBER EXEMPTION MATERIAL (in.) (an.) IWC-2600) POINTS REMARKS 26*-EBB-1 3A-EBB-1-23 1050 600 IB NON-EXEMPT C.S. 24 0.762 C-G 2B1 NON-EXEMPT C.S. 26 0.762 C-G 3A-E.BB-1-1 1050 600 2B2 NON-EXEMPT C.S. 26 0.762 C-G D IWC-1220(d) C.S. 1 HY/VIS IWC-5000 B NON-EXEMPT C.S. 26 0.762 C-G A NON-EXEMPT C.S. 26 0.762 C-G SR-1 NON-EXEMPT C-E-2 3B NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-2 1050 600 B NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1 11-1 NON-EXEMPT C-E-2 SR-2 NON-EXEMPT C-E-2 A NON-EXEMPT C.S. 26 0.762 C-G 4B NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-3 1050 600 SR-6 UON-EXEMPT C-E-2 4A IWC-1220 (d) C.S. 3/4 HY-VIS IWC-5000 4B1 IWC-1220 (d) C.S. 3/4 HY-VIS IWC-5000 B IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 A NON-EXEMPT C.S. 26 0.762 C-G-SB NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-4 1050 600 3A-EBB-1 H-2 NON-EXEMPT C-E-2 SR-7 NON-EXEMPT C-E-2 A NON-EXEMPT, C.S. 26 0.762 C-G 6B NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-22 1050 600 7B NON-EXEMPT G.S. 24 0.762 C-G 8B NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-5 1050 600 D IWC-1220 (d) C.S. 1 IIY-VIS IWC-5000 B NON-EXEMPT C.S. 26 0.762 C-G A NON-EXEV7 C.S. 26 0.762 C-G SR-3 NON-ext. M C-E-2 9B NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-6 1050 600 B NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1 H-3 NON-EXEMPT C-E-2 SR-4 NON-EXEMPT C-E-2 A NON-EXEMPT C.S. 26 0.762 C-G 10B NON-EXEMPT C.S. 26 0.762 C-G

- s s TECO/ DAVIS-BESSE WELD

SUMMARY

SilEET / UNIT 1 TABLE 1 SYSTEM MAIN STEAM (PEN 40) CLASS 2 . ISO NO.PM 203A,REV.18PalD NO. M-007, REV. 20 PAGE 2 OF 3 o o CODE 2W Z SECTION METHOD N5 2E ALLOWING PIPE DATA. OP 22y3 g5 EXEMPTION INSPECTION STRESS LINE SPOOL PIECE gWW 3W WELD SUPPORT OR NRC SIZE THICKNESh (TABLE DATA NUMBER NUMBER c8f ab NUMBER NUMBER EXEMPTION MATERIAL (in.) (m.) IWC-3600) POIN13 REMARKS 26"-EBB-l' 3A-EBB-1-7 1050 600 B IWC-1220 (d) C.S. 3/4 HY/VIS IWC-5000 (continued) S R-5 NON-EXEMPT C-E-2 A NON-EXEMPT C.S. 26 0.762 C-G llB NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-8 1050 600 3A-EBB-1 H-4 NON-EXIMPT C-E-2 S R-9 NON-EXEMPT C-E-2 A NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1 H-5 NON-EXEMPT C-E-2 SR-8 NON-EXEMPT C-E-2 12B NON-EXEMPT C.S. 26 0.762 C-G 36"-EBB-1 3A-EBB-1-9 1050 600 C NON-EXEMPT C.S. 36 1.055 C-G B NON-EXEMPT C.S. 36 1.055 C-G A NON-EXEMPT C.S. 36 1.055 C-G 13 NON-EXEMPT C.S. 36 1.055 C-G 3A-EBB-1-19 1050 600 A NON-EXEMPT C.S. 36 1.055 C-G 4 E NON-EXEMPT C.S. 48 1.52 C-G ANCHOR 81 NON-EXEMPT C-E-1 & 2 3A-EBB-1-19A 1050 600 13A NON-EXEMPT C.S. 36 1.055 C-G 14 NON-EXEMPT C.S. 36 2.375 C-G 33-5/8" ID x 3A-EBB-1-20 1050 600 T IWC-1220 (d) C.S. 1 3-3/8" Wall SURFACE CLAMP NON-EXEMPT HY/VIS IWC-5000 C-E-2 EBB-1 W NON-EXEMPT C.S. 6 2.375 C-G K HON-EXEMPT C.S. 6 1.155 C-G X HON-EXEMPT C.S. 6 2.375 C-G J NON-EXEMPT C.S. 6 1.155 C-G I NON-EXEMPT C.S. 6 1.155 C-G C-282 DET. RA NON-EXEMPT C+E-1 & 2 H NON-EXEMPT C.S. 6 1.155 C-G Al NON-EXEMPT C.S. 6 2.375 C-G G NON-EXEMPT C.S. 6 1.155 C-G B1 NON-EXEMPT C.S. 6 2.375 C-G F NON-EXEMPT C.S. 6 1.155 C-G E MON-EXEMPT C.S. 6 1.155 C-G C-282 DET. RB NON-EXEMPT C-0-1 & 2 D NON-EXEMPT C.S. 6 1.155 C-G El NON-EXEMPT C.S. 6 2.375 C-G C NON-EXEMPT C.S. 6 1.155 C-G 4 1 4

f, . -4 + TECO/ DAVIS oESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYlil'EM MAIN STEAM (PEN 40) CLASS 2 ISO NO.PM 203A,ftEV.18P&ID NO. tt-007,M-00 3, REV.20 PAGE 3 OF 3 h CODE o d Zy SECTION METHOD ZhD Z ALLOWING PIPE DATA OP 0, gg g 0 EXEMPTION INSPECTION STRESS LINE SPOOL PIECE ygg g WELD SUPPORT OR NRC SIZE THICKNESS (TABLE DATA NUMBER NUMBER o o a. o NUMBER NUMBER EXEMPTION MATERIAL (na.) (la.) IWC-2600) POINTS REMARKS 33-5/8" ID x 3A-EBB-1-20 1050 600 P NON-EXEMPT C.S. 8 0.406 C-G 3-3/8" Wall-(continued) SR-ll NON-EXEMPT C-E-1 & 2 EBB-1 O NON-EXEMPT C.S. 12 0.562 C-G (continued) N NON-EXEMPT C.S. 12 0.562 C-G R IWC-1220 (d) C.S. 1-1/2 HY/ IWC-5000 S IWC-1220 (d) C.S. 1-1/2 HY, 3 IWC-5000 15 NON-EXEMPT C.S. 36 1.055 C-G 36"-EBB-1 3A-EBB-1-21 1050 600 A NON-EXEMPT C.S. 36 1.055 C-G 15C IWC-1220 (d) C.S. 3/4 HY/VIS IWC-5000 15A IWC-1220 (d) C.S. 3/4 IIY/VIS IWC-5000 C-288 DET. 6 NON-EXEMPT C-E-1 & 2 ISB IWC-1220 (d) C.S. 3/4 HY/VIS IWC-5000 15D IWC-1220 (4) C.S. 3/4 HY/VIS IWC-5000 16 NON-EXEMPT C.S. 36 1.055 C-G 36"-EBD-1 3A-EBD-1-17 1050 600 17 NON-EXEMPT C.S. 36 1.055 C-G 3A.EBD-1-18 105' 600 ANCHOR 83 NON-EXEMPT C-E-1 & 2 8"-EBB-1 3A-EBB-1-30 1050 600 ISB NON-EXEMPT C.S. 8 0.406 C-G 15A NON-EXEMPT C.S. 8 0.406 C-G 3 NON-EXEMPT C.S. 8 0.406 C-G 4 l J

r TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 2 SYSTEM MAIN STEAM (PEN 40) CLASS 2 ISO NO. PM 203A,REV.18 P&lD NO. M-007, REV.20 PAGE 1 OF 1 PIPE DATA T1 TICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATER!AL (ie.) (in.) POINTS SYSTEM FUNCTION K Y Z 33"-EBB-1 3A-EBB-1-19 C C.S. 36 1.055 Main steam from steam C-G EX 1 HY/VIS generators to and B C.S. 36 1.055 including isolation ' C-G EX 1 HY /VJS valve MS 100 & 101 and P C.S. 48 1.52 MS 375 and MS 394. C-G EX 1 D C.S. 48 1.52 C-G EX 1 F C.S. 60 0.375 C-G EX 2 SURFACE 6"-EBB-2 3A-EBB-1-20 Q C.S. 6 0.28 C-G EX 8 IN/VIS L C.S. 6 0.28 C-G EX 8 HY/VIS-M C.S. 6 0.28 C-G EX 8 HY/VIS 33 5/8 ID x 3A-EBB-1-20 Y C.S. 6 2.375 C-G EX 1 HY/VIS, 204 C-G AND 3-3/8 wall SURFACE OBSTRUCTION EBB-1 Z C.S. 6 2.375 C-G EX 1 HY/VIS, 204 C-G AND SURFACE OBSTRUCT'O_3 e C1 C.S. 6 2.375 C-G EX 1 HY/VIS, 204 C-G AND SURFACE OBSTRUCTION D1 c.S. 6 2.375 C-G EX ] HY/VIS, 204 C-G AND SURFACE OBSTRUCTION l l

TECO/ DAVIS-BESSE UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 PM 203-B CYSTEM MAIN STEAM (PEN-39) CLASS 2 . ISO NO. REV.-16 P&lD No. M-007, REV-20 PAGE 1 OF 3 o o CODE Z 84 SECTION METHOD zN$ z ALLOWING PIPE DATA OF 2 y 58 9 EXEMPTION INSPECTION STRESS y ad O gg WELD SUPPORT OR NRC SIZE Tit 1CKNESb (TABLE DATA LINE SPOOL PIECE NUMBER NUM BER Q$f 00 NUMBER NUMBER EXEMPTION MATERIAL (im.) (in.) IWC-2600) POINTS REMARKS 26*-EBB-1 3A-EBB-1-26 1050 600 1A NON-EXEMPT C.S. 24 0.762 C-G 2A NON-EXEMPT C.S. 26 0.762 C-C 3A-EBB-1-10 1050 600 D IWC-1220(d) C.S. 1 HY/VIS IWC-5000 B NON-EXEMPT C.S. 26 0.762 C-G A NON-EXEMPT C.S. 26 0.762 C-G SR-1 NON-EXEMPT C-E-2 3A IKel-EXEMPT C. S.- 26 0.762 C-G 3A-EBB-1-11 1050 600 B NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1 H-1 NON-EXEMPT C-E-2 S R-2 NON-EXEMPT C-E-2 A NON-EXI.MPT C.S. 26 0.762 C-G 4A NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-12 1050 600 4A-1 IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 48 IWC-1220 (d) C.S. 3/4 HY/VIS IWC-5000 B IWC-1220(d) C.S. 3/4 NY/VIS IWC-5000 S R-6 NON-EXEMPT C-E-2 A NON-EXEMPT C.S. 26 0.762 C-G 5A Noti-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-13 1050 600 3A-EBB-1 H-1 NON-EXDiPT C-E-2 S R-7 NON-EXEMPT C-E-2 A NON-EXEMPT C.S. 26 0.762 C-G 6A NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-25 1050 600 7A NON-EXEMPT C.S. 24 0.762 C-G 8A NON-EXEMPT C.Se 26 0.762 C-G 3A-EBB-1-14 1050 600 C IWC-1220(d) C.S. 1 HY/VIS IWC-5000 B NON-EXEMPT C.S. 26 0.762 C-G A NON-EXEMPT C.S. 26 0.762 C-G S R-3 NON-EXEMPT C-E-2 9A NON-EXEMPT C.S. 26 0.762 C-G a 3A-EBB-1-15 1050 600 B NCU-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1 H-3 NON-EXEMPT ~ C-E-2 SR-4 NON-EXEMPT C-E-2 A NON-EXEMPT C.S. 26 0.762 C-G 10A NON-EXEMPT C.S. 26 0.762 C-G e e

TECO/DAVIb ESSE / UNIT 1 WELD

SUMMARY

SIIELT - TABLE 1 CYS"IEM MAIN S7EMI (Pt23-39) CLASS 2 . ISO NO. m 203-B P&lD NO. M-007, REV. 20 PAGE 2 OF 3 REU. 16 o o CODE zW Z SECTION ME'IllOD zNh 5 ALLOWING PIPE DATA OF z$ 05d O EXEM_' TION INSFELTION STRESS LINE SPOOL PIECE gWW yW WELD SUPPORT OR NRC SIZE THICKNESd (TABLE DATA NUMBER NUMBER QoN QQh NUMBER NUMSER EXEMPTION MATERIAL (in.) (im.) IWC-2600) POINTS REMARKS 26"-EBB-1 3A-EBB-1-16 1050 600 B IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 (continued)

R-5 NON-EXEMPT C-E-2 A

NON-EXEMPT C.S. 26 0.762 C-G llA NON-EXEMPT C.S. 26 0.762 C-G 3A-EBB-1-17 1050 600 3A-EBS-1 H-4 NON-EXEMPT C-E-2 3R-9 NON-EXEMPT C-E-2 A NON-EXEMPT C.S. 26 0.762 C-G SR-8 NON-F** MPT C-E-2 3A-EBB-1 H-5 NON-h4MPT C-E-2 12A 'NON-EXEMPT C.S. 26 0.762 C-C 36"-EBB-1 3A-EBB-1-18 1050 600 B NON-EXEMPT C.S. 36 1.055 C-G A NON-EXEMPT C.S. 36 1.055 C-G C riON-EXEMPT C.S. 36 1.055 C-G NON-EM:M17@{ % 3A-EBB-1-27 1050 600 13 C.S. 36 1.055 C-G A NON-EXEN.= C.S. 36 1.055 C-G = E NON-EXEMPT C.S. 48 1.52 C-G 3A-EBB-1-27A 1050 600 13A NON-EXEMPT C.S. 36 1.055 C-G 14 NON-EXEMPT C.S. 36 1.055 C-G 33-5/8 ID x 3-3/8 WALL 3A-EBB-1-28 1050 600 U IWC-1220(d) C.S. 1 HY/VIS IWC-5000 EBB-1 SURFACE CIAMP NON-EXEMPT C-E-2 X NON-EXEMPT C.S. 6 2.375 C-G L NON-EXEMPT C.S. 6 1.155 C-G K NON-EXEMPT C.S. 6 1.155 C-G I NON-EXEMPT C.S. 6 1.155 C-G l Al C-282 RESTR. SEC.5 NON-EXEMPT C-E-l&2' NON-EXEMPT C.S. G 2.375 C-G H NON-EXEMPT C.S. 6 1.155 C-G B1 NON-EXEMPT C.S. 6 2.375 C-G G NON-EXEMPT C.S. 6 1.155 C-C Cl NON-EXEMPT C.S. 6 2.375 C-G F NON-EXEMPT C.S. 6 1.155 C-G E NON-EXEMPT C.S. 6 1.155 C-G D NON-EXEMPT C.S. 6 1.155 C-G F1 NON-EXEMPT C.S. 6 2.375 C-G C NON-EXEMPT C.S. 6 1.155 C-C e

r TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 1 P 20 B SYSTEM MAIN STEAM (PEN-39) CLASS 2 . ISO NO. P&lD NO. M-007, REV. 20 PAGE 3 OF 3 p n o CODE Efd SECTION ME1110D bN 2 ALLOWING PIPE DATA OF 295$ 2 EXE34PTION INSPECTION STRESS LINE SPOO' <lECE ygg gy WELD SUPPORT OR NRC SIZE THICKNESS (TABLE DATA NUMBER NsMBER QC QO NUMBER NUMBER EXEMPTION MATERIAL (in.) (in.) IWC-2600) POINTS REMARKS C"-EBB-1 3A-Et3-1-28 1050 600 Q NON-EXEMPT C.S. 8 0.406 C-G 20 NON-EXEMPT C.S. 8 0.406 C-G 3A-EBB-1-31 1050 600 19 ION-EXEMPT C.S. 8 0.406 C-G B NON-EXEMPT C.S. 8 0.406 C-G 33-5/8 ID x 3A-EBB-1-28 1050 600 C-282 RESTR.DET.5 NON-EXEMPT ~ ~ C-E-l&2 2-3/8 WALL S R-19 NON-EXEMPT C-E-l&2 EBB-1 P HON-EXEMPT C.S. 12 0.562 C-G A NON-EXEMPT C.S. 12 0.562 C-G H IWC-1220(d) C.S. 1 HY/VIS IWC-5000 T IWC-1220 (d) C.S. 1 HY/VIS IWC-5000 36"-EBB-1 3A-EBB-1-29 1050 600 15 NON-EXEMPT C.S. 36 1.055 C-G A NON-EXEMPT C.S. 36 1.055 C-G 15C IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 15A IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 C-283 RESTR. SEC 4 NON-EXEMPT C-E-l&2 ISB IWC-1220(d) C.S. 3/4 HY/VIS IWC-5%0 ISD IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 16 NON-EXEMPT C.S. 36 1.055 C-C 3A-EBD-16A 1050 600 11 NON-EXEMPT C.S. 36 1.055 C-G 1 l

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM MAIN STEAM (PEN-39) CLASS 2 ISO NO. PM 203B REV. 16 PalD NO. M-007, REV. 20 PAGE 1 OF 1 PIPE DATA TillCK-6 TRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL bn.) On.) POINTS JYSTEM FUNCTION K Y Z 36"-EBB-1 3A-EBB-27 C C.S. 36 1.055 Main steam from steam C-G EX 1 !!Y/VIS generators to & includ-B C.S. 36 1.055 ing isolation valve C-G EX 1 HY/VIS MSIOO & 101 & MS375 s P C.S. 48 1.52 MS334. C-G EX 1 D C.S. 48 1.52 C-G EX 1 F C.S. 60 0.375 C-G EX 2 SURFACE 6"-EBB-2 3A-EBB-1-28 R C.S. 6 0.28 C-G EX 8 HY/VIS M C.S. 6 0.28 C-G EX 8 HY/VIS N C.S. 6 0.28 C-C EX 8 HY/VIS 33-5/8 ID x 3A-EBB-1-28 Y C.S. 6 2.375 C-G EX 1 HY/VIS, 20% C-G AND 3-3/8 WALL SURFACE OBSTRUCTION EBB-1 Z C.S. 6 2.375 C-G EX 1 IIY/VIS, 20% C-G AND SURFACE OBSTRUCTION D1 C.S. 6 2.375 C-G EX 1 HY/VIS, 20% C-G AND SURFACE OBSTRUCTION El C.S. 6 2.375 C-G EX 1 HY/VIS, 20% C-G AND SURFACE OBSTRUCTIOil 8"-EBB-1 3A-EBB-1-28 20 C.S. 8 0.406 C-G EX 1 HY/VIS

TECC/ DAVIS-BESSE/ UNIT 1 WELD SUldMARY SilEET - TABLE 1 CYSTEM MAIN STEAM CLASS 2 ISO NO. PM 203 J,REV.3 P&ID NO. M-003, REV. 20 PAGE 1 OF 2 e o CODE 55 2g zW SECTION METHOD ALIAWING PIPE DATA OF 2Sjg 2$ EXEMPTiot. INSPECTION STRESS LINE SPOOL PIECE yWW gg WELD SUPPORT OR NRC SIZE THICKNESE (TABLE DATA NUMBER NUMBER Q$f QO NUMBEP. NUMBER EXEMPTION MATERIAL (ia.) (in.) IWC-2600) POIN'ill REMARKS 6"-EBB-2 3A-EBB-2-1 1050 600 3A-EB8-2 H-ll NON-EXEMPT C-E-2 1A IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 3A-EBB-2 H-12 NON-EXEMPT ~ C-E-2 3A-EBB-2 H-13 NON-EXEMPT C-E-2 ANCHOR 8246 NON-EXEMPT C-E-l&2 3A-EBB-2-2 1050 600 3A-EBB-2 H-14 NON-EXEMPT C-E-l&2 3A-EBB-2 H-15 NON-EXEMPT ~ C-E-l&2 3A-EBB-2-3 1050 600 ANCHOR #251 NON-EXEMPT C-E-l&2 3A-EBB-2-4 1050 600 3A-EBB-2 H-25 NON-EXEMPT ~ C-E-2 F IWC-1220(d) C.S. 1-1/2 G IWC-1220(d) C.S. 1 HY/VIS IWC-5000 HY/VIS IWC-5000 3A-EBB-2 H-22 NON-EXEMPT ~ ~ ~ C-E-2 3A-EBB-2 H-23 NON-EXEMPT ~ ~ C-E-l&2 6"-EBD-19 3A-EBD-19-7B 1050 600 ANCHOR #310 NON-EXEMPT ~ ~ ~ C-E-l&2 6"-EBB-2 3A-EBB-2-5 1050 600 3A-EBB-2 H-26 NON-EXEMPT ~ ~ C-E-l&2 3A-EBB-2 H-28 NON-EXEMPT ~ ~ C-E-l&2 3A-EBB-2 H-27 NON-EXEMPT ~ ~ ~ C-E-2 3A-EBB-2 H-29 NON-EXEMPT ~ C-E-2 3A-EBB-2-6 1050 600 3A-EBB-2 H-30 NON-EXEMPT C-E-2 =

    • --EBB-2 H-31 NON-EXEMPT

~ ~ ~ C-E-2 H IWC-127 3(d) C.S. 1-1/2 ~ HY/VIS IWC-5000 J IWC-l*20(d) C.S. 1 HY/VIS IWC-5000 3A-EBD-19-36 1050 600 ANCHOR 9309 NON-EXEMPT ~ ~ ~ C-E-1&2' 3A-EBB-2-7 1050 600 3A-EBB-2 H-1 NON-EXEMPT ~ ~ ~ C-E-2 3A-EBB-2 H-2 NON-EXEMPT ~ ~ C-E-2 3A-EBB-2 H-3 NON-EXEMPT ~ ~ C-E-2 3A-EBB-2 H-4 NON-EXEMPT ~ ~ C-E-2 3A-EBB-2 H-5 NON-EXEMPT ~ ~ C-E-2 3A-EBB-2-8 1050 600 3A-EBB-2 H-6 NON-EXEMPT C-E-2 = 3A-EBB-2 H-6A NON-EXEMPT ~ ~ C-E-2 3A-EBB-2 H-7 NON-EXEMPT ~ ~ ~ C-E-2 3A-EBB-2 H-7A NON-EXEMPT ~ ~ ~ C-E-2 3A-EBB-2-9 1050 600 3A-EBB-2 H-8 NON-EXEMPT C-E-2 3A-EBB-2 H-9 NON-EXEMPT ~ ~ ~ C-E-2

r TECO/DAV4 -BESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 1 MMM MAIN STEAM CLASS 2 . ISO NO. PM 203 J,REV.3 P&lD NO. M-003, REV. 20 PAGE 2 OF 2 O O CODE W SECTION ME11tOD ALLOWING PIPE DATA OF Z 2 2 y 25 EXEMPTION INSPECTION STRESS LINE SPOCL PIECE $WW yy WELD SUPPORT OR NRC S!ZE ThlCKNESh (TABLE DATA NUMBER NUMBER QOf QO NUMBER NUMBER EXEMPTION MATERIAL (im.) (sa.) IWC-2600) POINTS REMARKS 6"-EBB-2 3A-EBB-2-10 1050 600 ANCHOR 8240 - NON-EXEMPT C-E-lE2 (continued) 3A-EBB-2 H-10 3 -EXEMPT C-E-2 3A-EBB-2-Il 1050 600 ANQ10R 82 NON-EXEMPT C-E-l&2 3A-EBB-2 H-16 NON-EXEMPT C-E-lE2 3A-EBB-2-15 1050 600 3A-EBB-2 H-17 NON-EXEMPT C-E-l&2 3A-EBB-2-16 1050 600 ANCHOR 84 NON-EXEMPT C-E-lE2 3A-EBB-2-13 1050 600 3A-EBB-2 H-19 NON-EXEMPT C-E-lE2 3A-EBB-2 H-20 NON-EXEMPT C-E-2 3A-EBB-2-14 1050 600 3A-EBB-2 H-21 NON-EXEMPT C-E-lE2 C IWC-1220(d) C.S. 4 S.237 HY/VIS IWC-5000 D IWC-1220(d) C.S. 4 \\0.237 HY/VIS IWC-5000 E IWC-1220(d) C.S. 1 1/2 HY/VIS IWC-5000 F IWC-1220(d) C.S. 1 HY/VIS IWC-5000 t I

? m TECO/ DAVIS-BESSE UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 CYSTEM MAIN STEAM CLASS 2 ISO NO. PM 203Jjmy,3 PalD NO. M-013, REV. 20 PAGE 1 OF 7 PIPE DATA TillCK-IrrRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER HUMBER SUPPORT NUMBFR MATERIAL (ia.) (in. ) POIN13 SYSTEM FUNCTION X Y Z 6"-EBB-2 3A-EBB-2-1 1 C.S. 6 0.280 Main steam line to aux. C-G EX 8 SURFACE feed pump turbines up to E including motor operated valves MS106 & 107. IB C.S. 6 0.280 C-G EX 8 SURFACE B C.S. 6 0.280 C-G EX 8 SURFACE C C.S. 6 0.280 C-G EX 0 SURFACE D C.S. 6 0.200 C-G EX 8 SURFACE E c,s, 6 d.280 C-G EX 8 SURFACE F C.S. 6 0.280 C-G EX 0 SURFACE 3A-EBB-2-2 2 C.S. 6 0.280 -C-G EX 8 SURFACE A C.S. 6 0.280 C-G EX B SURFACE 2A C.S. 6 0.280 C-G EX 8 SURFACE C C.S. 6 0.280 C-G EX 8 SURFACE 3 C.S. 6 0.280 C-G EX 8 SURFACE 4 C.S. 6 0.280 C-G EX 8 SURFACE (

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 2 SYSTEM MAIN STEAM CLASS 2 ISO NO. PM 203J,REV. 3 PalD No. M-003, REV. 20 PAGE 2 OF 7 PIPE DATA TillCK-STRESS IJNE SPOOL PIFCE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT PUMBER MATERIAL (sn.) (6n.) POINTS SYSTEM FUNCTION X Y Z 6*-EBB-2 3A-EBB-2-3 5 C.S. 6 0.280 Main steam line to aux. C-G EX 8 SURFACE (continued) feed pump turbines up to & including motor operated valves NS106 4 1U7. F C.S. 6 0.280 C-G EX 8 SURFACE E C.S. 6 0.280 C-G EX 8 SURFACE D C.S. 6 0.280 C-G EX 8 SURFACE C C.S. 6 0.280 C-G EX 8 SURFACE 3A-EBB-2-4 6 C.S. 6 0.280 C-G EX 8 SURFACE A C.S. 6 0.280 C #. EX 8 SURFACE B C.S. 6 0.280 .C-G E19 SURFACE C C.S. 6 0.280 C-G EX-8 ' SURFACE D C.S. 6 0.280 C-G EX-0 SURFACE E C.S. 6 0.280 C-G EX-8 SURFACE 7 C.S. 6 0.280 C-G EX-8 SURFACE 76 C.S. 6 0.280 C-G EX-8 SURFACE 4

h TECO/DAV S-BESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 2 LYSTEM MAIN STEAM CLASS 2 ISO NO. PM 203J,REV. 3 P&lD NO. M-00 3, REV. 20 PAGE 3 OF 7 l PIPE DATA TillCK-STRESS LINE SPOOL PIECE i WELD SIZE NESS DATA NUMdER HUMBER NUMBER SUPPORT NUMBER MATERIAL (en.) (is.) POINTS SYSTEM FUNCTION X Y Z G"-EBB-2 3A-EBB-2-5 8 C.S. 6 0.280 Main steam lina to aux. C-G EX 8 SURFACE fcontinued) feed pump turbines up to s including motor operated valves MS106 s 107. 3A-EBB-2-6 9' C.S. 6 0.280 C-G EA 8 SURFACE A C.S. 6 0.280 C-G EX 8 SURFACE B C.S. 6 0.280 C-G EX 8 SURFACE C C.S. 6 0 280 C-G EX 8 SURFACE D C.S. 6 0.280 C-G EX 8 SURFACE E C.S. 6 0.280 C-G EX 8 SURFACE F C.S. 6 0.280 C-G EX 8 SURFACE G C.S. 6 0.280 C-G EX 8 SURFACE 10 C.S. 6 0.280 C-G EX 8 SURFACE 25 C.S. 6 0.280 C-G EX 8 SURFACE I

s TECO/ DAVIS-oESSE/ UNIT 1 WELD

SUMMARY

SilEET - TAP.~.2 2 CYSTEM MAIN STEAM CLASS 2 ISO NO. PM 20 3J, REV. 3 P&lD NO. M-003, REV. 20 PAGE 4 OF 7 PIPE DATA THICK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER HUMBER NUMBER SUPPORT NUMBER MATERIAL (ia.) (ia.) POINTS SYSTEM FUNCTION 1 Y Z 6"-EBB-2 3A-EBB-2-7, 11 C.S. 6 0.280 Main steam line to aux. C-G EX 8 SURFACE (continued) feed pump turbines up to & including motor 11C C.S. 6 0.280 operated valves MS106 C-G EX-8 SURFACE & 107 11B C.S. 6 0.280 C-G EX 8 SURFACE A C.S. 6 0.280 CH3 EX 8 SURFACE B C.S. 6 0.280 C-G EX 8 SURI ACE 11A C.S. 6 0.280 C-G EX 8 SURFACE C C.S. 6 0.280 C-G EX 8 SURFACE D C.S. 6 0.280 C-G EX 8 SURFACE 31.-EBB-2-8 12 C.S. 6 0.280 C-G EX 8 SURFACE A C.S. 6 0.280 C-G EX 8 SURFACE 3A-EBB-2-9 13 C.S. 6 0.280 C-G EX 8 SURFACE A C.S. 6 0.200 C-G EX 8 SURFACE B C.S. 6 0.280 C-G EX 8 SURFACE C C.S. 6 0.280 C-G EX 8 SURFACE d

l' 7 F O Z E E E E E E E E E E E E E C C C C C C C C C C C C C A A A A A A A A A A A A A F F F F F F F F F F F F F R R R R R R R R R R R R R U U U U U U U U U U U U U 5 S S S S S S S S S S S S S E GA 8 8 8 8 8 8 8 0 8 8 8 8 8 P Y X X X X X X X X X X X X X E E E E E E E E E E E E E G G G G G G G G G G G G G 0 K 2 C C C C C C C C C C C C C VE R xup 6 aur0 3 N o1 O ostS 0 I t eoM 0 T C nm M N ei s nb ge U irnv F l uil td a O M m uv E apl N T emcd S t une D Y spit I S a7 nd& r0 P ie e1 aeop Mf t os 3 S S SAT V ETN 2 E RAI TDO E R, S P 1 L J B T 3 A 0 IN T 2 KS) CS. 0 0 0 0 0 0 0 0 0 0 0 0 0 U lei 8 8 0 8 8 8 8 8 8 8 8 8 8 n / - M liN( 2 2 2 2 2 2 2 2 2 2 2 2 2 E P T T S E O. 0 0 0 0 0 0 0 0 0 0 0 0 0 S E El Bi N A S T E )n. SY O A I S ( 6 6 6 6 6 6 6 6 6 6 6 6 6 Zi S D I I R V A E A P DM I L P /M A 2 OU I R CS E S. E T S. S. S.. S.. S. S. S. S. S. S. S. S. TD S A C C C C C C C C C C C C C L S M E A W LC R EB MU N TR O PPU S R DE LB A EM 4 A B C D 4 5 6 7 B C 2 A WU 1 1 1 1 1 2 N E 0 l 5 1 l 1 C M ER A IE 2 2 2 E B P B B B T LM B B B S OU E E E ON N P A A A E 3 3 3 IAM ) d R e EE 2 u B - n N M M Bi I E LU Bt T N E n - o S Y 6 (c S

pM TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM MAIN STEAM CLASS 2 ISO No. PM 203J,REV. 3 P&ID NO. M-003, REV. 20 PAGE 6 OF 7_ l PIPE DATA I THICK-STRESS SIZE NESS 1ATA LINE SPOOL PIECE WELD NUMBER NUMBER NUMBEP SUPPORT NUMBER MATERIAL (in.) (ia.) FL:NTS SYSTEM FUNCTION 1 Y Z 6"-EBB-2 3A-EBB-2-16 23 C.S. 6 0.280 Main Steam line to aux. C-G EX 8 SURFACE (continued) feed pump turbines up to & including motor operated valves MS106 s 107. A C.S. 6 0.200 C-G EX 8 SURFACE a B C.S. 6 0.280 m EX 8 SURFACE C C.S. 6 0.280 C-G EX 8 SURFACE F C.S. 6 0.2oe C-G EX 0 SURFACE D C.S. 6 0.280 C-G EX 8 SURFACE G C.S. 6 0.280 C-G EX 8 SURFACE E C.S. 6 0.280 C-G EX 0 SURFACE 24 C.S. 6 0.280 C-G EX 8 SURFACE Ss C.S. 6 0.280 C-G EX 8 SURFACE 3A-EBB-2-12 18 C.S. 6 0.280 C-G EX 0 SURFACE A C.S. 6 0.280 C-G EX 8 SURFACE f

TECO/IJAVIS-BESSE/ UNIT 1 WELD

SUMMARY

S!!EET - TABLE 2 SYSTEM MAIN STEAM CLASS 2 ISO NO. PM 203J,REV. 3 P&lD NO. M-003, REV. 20 PAGE 7 OF 7 PIPE DATA TIIICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (aa.) (in.) POINTS SYSTEM FUNCTION X Y Z &*-EBB-2 3A-EBB-2-13 19 C.S. 6 0.280 Main steam line to aux. C-G EX 8 SURFACE (continued) f..M pump tcrbines up to and including motor A C.S. 6 0.280 operated valves MS106 C-G EX-8 SURFACE & 107. B C.S. 6 0.280 C-C EX 8 SURFACE 20 C.S. 6 0.280 C-G EX 8 SURFACE 3A-E.BB-2-14 A C.S. 6 0.280 C-G EX 8 SURFACE B C.S. 6 0.280 C-C EX 8 SURFACE 21 C.S. 6 0.280 C-G EX 0 SURFACE I 56 C.S. 6 .280 C-G EX R SURFACE

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE I SYSTEM AUXILIARY FEEDWATER CLASS 2. . ISO NO. PM206E';REV.10 P&lD NO. M-007, REV. 20 PAGE 1 OF 3 0 0 CODE ZW SECTION ME11tOO zE$ g ALLOWING PIPE DATA OF 2[$ 2 EXEMPTION INSPECTION STRESS LINE SPOOL PIECE $gW g WELD SUPPORT OR NRC SIZE THICKNESh (TABLE DATA NUMBER NUMBER oof a h NUMBER NUMBER EXEMPTION MATERIAL (in.) (ia.) IWC-2600) POINTS REMARKS 4"-EBB-4 6C-EBB-4-10 1200 300 57 NON-EXEMPT C.S. 6 0.432 C-G A NON-EXEMPT C.S. 6 0.432 C-G B NON-EXEMPT C.S. 6 0.432 C-G 6C-EBB-4-9 1200 300 56 NON-EXEMPT C.S. 6 0.432 C-G C NON-EXEMM C.S. 6 0.432 C-G B NON-EXEMPT C.S. 6 0.432 C-G A NON-EXEMPT C.S. 6 0.432 C-G 6C-EBB-4 H-7 HON-EXEMPT C-E-lE2 6C-EBB-4 H-5 NON-EXEMPT C-E-2 6C-EBB-4 H-6 NON-EXEMPT C-E-l&2 6C-EBB-4 H-4 NON-EY_EMPT C-E-2 D NON-EXEMPT C.S. 6 0.432 C-G 6C-EBB-4-ll 1200 300 55 NON-EXEMPT C45. 6 0.432 C-G B NON-EXEMPT C.S. 6 0.432 C-G A NON-EXEMPT C.S. 6 0.432 C-G 6C-EBB-4-8 1200 300 6C-EBB-4 H-3 NON-EXEMPT C-E-2 3 NON-EXEMPT C.S. 6 0.432 C-G A NON-EXEMPT C.S. 6 0.432 C-G C NON-EXEMPT C.S. 6 0.432 C-G 538 IWC-1220 (d) C.S. 1 HY/VIS IWC-5000 53A IWC-1220 (d) C.S. 1 HY/VIS IWC-5000 D IWC-1220 (d) C.S. 1 tIY/VIS IWC-5000 6C-EBB-4-7 1200 300 53 NON-EXEMPT C.S. 6 0.432 C-G 52B NON-EXEMPT C.S. 6 0.432 C-G 52A NON-EXEMPT C.S. 6 0.432 C-G 6C-EBD-4 H-1 NON-EXEMPT C-E-2 1 6C-EBB-4-6 1200 30v 52 NON-EXEMPT C.S. 6 0.432 C-G 5 NON-EXEMPT C.S. 6 0.432 C-G l 6C-EBB-4 H-2 NON-EXEMPT C-E-2 51A NON-EXEMPT C.S. 6 0.432 C-G A NON-EXEMPT C.S. 6 0.432 C-G ) 51 NON-EXEMPT C.S. 6 0.432 C-G

TECO/ DAVIS- .iSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 CYSTEM AUXILIARY FEEDWATER CLASS 2 . ISO NO.PM 206F,REV.10P&II) NO. M-007, REV. 20 PAGE 2 OF 3 o o CODF y g SECThde MElllOD Z D 2 ALLOwnNG PIPE DATA OF 2$M 2h EXEMPTION INSPECTION STRESS LINE SPOOL PIECE $WU gg WELD SUPPORT OR NRC SIZE TlHCKNESh (TABLE DATA NUMBER HUMBER cof och NUMBER NUMBER EXEMPTION MATEh!AL (an.) (ia.) IWC-2600) POINTS REMARKS 6"-EBD-14 6C-EBD-14-7 1350 300 ANCHOR 8223 NON-EXEMPT C-E-l&2 6"-EBB-4 6C-EBB-4-12 1200 300 1 NON-EXEMPT C.S. 6 0.432 C-G B NON-EXEMPT C.S. 6 0.432 C-G A NON-EXEPPT C.S. 6 0.432 C-G 6C-EBB-4-1 1200 300 2 NON-EXEMPT C.S. 6 0.432 C-G B NON-EXEMPT C.S. 6 0.432 C-G A NON TXEMPT C.S. 6 0.432 C-G 6C-EBB-4-2 1200 300 3 NON-EXEMPT C.S. 6 0.432 C-G 6C-EBB-4 H-15 NON-EXEMPT C-E-2 A NON-EXEMPT C.S. 6 0.432 C-G C NON-EXEMPT C.S. 6 0.432 C-G 6C-EBB-4-3 1200 300 4 NON-EXEMPT C.S. 6 0.432 C-G 6C-EBB-4 H-12 NON-EXEMPT C-E-l&2 6C-EBB-4 H-14 NON-EXEMPT C-E-l&2 6C-EBB-4 H-16 NON-EXEMPT C-E-2 A NON-EXEMPT C.S. 6 0.432 C-G 6C-EBB-4-13 1200 300 5 TN-EXEMPT C.S. 6 0.432 C-G A NON-EXEMPT C.S. 6 0.432 C-G B NON-EXEMPT C.S. 6 0.432 C-G SA NON-EXEMPT C.S. 6 0.432 C-G 6C-EBB-4 H-S NON-EXEMPT C-E-2 6C-EBB-4 H-9 NON-EXEMPT C-E-l&2 6C-EBB-4 H-lO NON-EXEMPT C-E-l&2 6C-EBB-4 H-ll NON-EXEMPT C-E-l&2 C NON-EXEMPT C.S. 6 0.432 C-G 6C-EBB-4 11-17 NON-EXEMPT C-E-l&2 D NON-EXEMPT C.S. 6 0.432 C-G F IwC-122O (d) C.S. 1 try/VIS IWC-5000 E NON-EXEMPT C.S. 6 0.432 C-G

TECO/DAVlo-BECSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYb7EM AUXILIARY FEEDWATER CLASS 2 . ISO NOSM 206F,REV.10PalD NO. M-007, REV. 20 PAGE 3 OF 3 O O CODE zW i "CI10N METilOD zE$ ALLOWING PIPE DATA OF z4 2$$ 2 a: EXEMPTION INSPECTION STRESS LINE SPOOL PIECE yWW gW WELD SUPPORT OR NRC SIZE TlHCKNESb (TABLE DATA NUMBER NUMBER QOf coh NUMBER NUMBER EXEMPTION MATERIAL (an. ) (am.) IWC-2600) POINTS Rt34 ARKS 4"-EBB-4 6C-EBB-4-4 1200 300 6 (continued) NON-EXEMPT C.S. 6 0.432 C-G 6A NON-EXEMPT C.S. 6 0.432 6B C-G NON-EXEMPT C.S. 6 0.432 6C C-G NON-EXEMPT C.S. 6 0.432 c_c 6C-EBB 5 1200 300 7A NON-EXEMPT C.S. 6 0.432 C-G B NON-EXEMPT C.S. 6 0.432 C-G 4"-EBD-14 6C-EBD-14-21 1350 300 9 NON-EXEMPT C.S. 6 0.432 C-G 6C-EBD-14-22 1350 300 AIK2iOR #224 NON-EXEMPT C-E-1 & 2

TECO/ DAVIS-DESSE WELD

SUMMARY

SiiEET / UNIT } 2 TABLE SYSTEM AUXILIARY FEEDWATER CLASS 2 ISO NO. PM 206F, REV.10 P&ID NO. M-007, RSV. 20 PAGE 1 OF 1 PIPE DATA THICK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER-NUMBER NUMBER SUPPORT NUMBER MATERIAL (a) (ie. ) POINTS SYSTEM FUNCTION X Y Z 6".-EBS-4 6C-EBB-4-8 54 C.S. 6 0.432 Auxiliary feed pump C-G EX 1 NY/VIS, 506 C-G AND discharge to steam SU.tFACE OBSTRUCTION generator No. 1-2 4"-EBD-14 6C-EBD-14-1 50 C.S. 6 0.432 (through penetration C-G EX 1 HY/VIS, 506 C-G AND Ho. 35) downstream SURFACE OBSTIEJCTION or valve AF-599. 6"-EBB-4 6C-EBB-4-4 A C.S. 6 0.432 C-G EX 2 SURFACM 6C-EEB-4-5 7 C.S. 6 0.432 C-G EX 1 HY/VIS, 20% C-G AND SURFACE OBSTRUCTION A C.S. 6 0.432 C-G EX 1 HY/VIS, 20% C-C 'ND SURFACE OBSTRULTION l 4 .e ~

TECO/ DAVIS-bdSSE/ UNIT 1 WELD

SUMMARY

S)lELT - TABLE 1 M 207A SYSTEM STEAM GENERATOR DRAINS CLASS 2 . ISO NO. P&lD NO. M-007, REV. 20 PAGE1 OF 1 3 o CODE ZW SECTION ME1 HOD E$ z ALIDWING PIPE DATA OF 22$$ 2 EXEMPTION INSPECT.ON STRESS LINE SPOOL PIECE 3WW 3 WELD SUPPORT OR NRC SIZE THICKNESb (TABLE DATA NUMBER NUMBER Qof a NUMBER HUMBER EXEMPTION MATERIAL (in.) (en.) IWC-2600) POINTS REMARKS 4*-EBB-5 7-EBB-5-1 1100 540 ALL ALL IWC-1220(d) C.S. 4 0.237 HY/VIS IWC-5000 7-EBB-5-2 1100 540 ALL ALL IWC-1220(d) C.S. 4 'O."37 HY/VIS IWC-5000 7-EBB-5-3 1100 540 ALL ALL IWC-1220(d) C.S. 4 0.237 HY/VIS IWC-5000 7-EBB-5-4 1100 540 ALL ALL IWC 1220(d) C.S. 4 0.237 HY/VIS IWC-5000 7-EBB-5-5 1100 540 ALL ALL IWC 1220(d) C.S. 4 0.237 HY/VIS 7:ac-5000 7-EBB-5-6 1!00 540 ALL ALL IWC-1220(d) C.S. 4 0.237 HY/VIS iWC-5000 7-EBB-5-7 1100 540 ALL ALL IWC-1220(d) C.S. 4 0.237 HY/VIS IWC-5000 7-EBB-5-8 1100 540 ALL ALL IWC-1220(d) C.S. 4 0.237 HY/VIS IWC-5000 e 0 4

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 1 SYsn:M STEAM GENERATOR DRAINS CLASS 2 . ISO NO. REV P&ID NO. M-007, REV. 20 PAGE 1 OF 1 oh CODE o W Z SECHON MEDIOD QjM$ z) N ALLOWING PIPE wATA OP 2 g EXEMPTION INSPECTION STRESS LINE SPOOL PIECE 3w0 gg6 WELD StlPPORT OR NRC SIZE TH3CKNESS (TABLE DATA NUMBER NUMBER cof cop NUMBER NUM BER EXEMPTION MATERIAL (m) (m) IWC-2600) POINTS REMARKS 4* EBB-5 7-EBB-5-9 1100 540 All All IWC-1220 (d) C.S. 4 0.27" HY/VIS IWC-5000 4"-EBD-61 7-EBD-61-1 1100 540 3 IWC-1220 (d) C.S. 4 0.237 HY/VIS IWC-5000 Anchor til IWC-1220 (d) HY-VIS IWC-5000 4"-EBB-5 7-EBB-5-8 1100 540 All All IWC-1220 (d) C.S. 4 0.237 HY/VIS I*ac-5000 7-EBB-5-10 1100 540 All All IWC-1220 (d) C.S. 4 0.237 NY/VIS IWC-5000 4"-EBD-61 7-EBD-61-26 1100 540 36 IWC-1220 (d) C.S. 4 0.237 HY/VIS IWC-5000 Anchor 816 IWC-1220 (d) !!Y/VIS IWC-50M I I f

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 1 SYSTEM MAIN FEEDWATER CLASS 2 . ISO NO.PM 207C,REV.llP&lD NO. M-007, REV. 20 PAGE 1 OF 3 o CODE y SECTION METHOD Z zh ALLOWING PIPE DATA OF 2 D 0 2g EXEMPTION INSPECTION STRESS LINE SPOOL PIECE g Qgg W 'LD SUPPORT OR NRC SIZE THICKNESa (TABLE DATA NUM BER NUMBER Q a. QOp NLa4BER NUMBER EXEMPTION MATERIAL (un.) (ie.) IWC-2600) POINTS REMARKS 14"-EBB-3 7-EBB-3-11 1200 470 35 NON-EXEMPT C.S. 14 0.750 C-G 34 NON-EXEMPT C.S. 14 0.750 C-G 7-EBB-3-8 1200 470 A NON-EXEMPT C.S. 14 0.750 C-G C-613 SR-24 NON-EXEMPT C-E-2 C-613 SR-25 NON-EXEMPT C-E-2 C IWC-1220 (d) C.S. 1 HY/VIS IWC-5000 33 NON-EXEMPT C.S. 14 0.750 C-G 7-EBB-3-3 1200 470 E HON-EXEMPT C.S. 14 0.750 C-G D NON-2XF#PT C.S. 14 0.750 C-G C NON-EXEMPT C.S. 14 0.750 C-G C-613 H-12 NON-EXEMPT C-E- 2 C-613 SR-26 NON-EXEMPT C-E-2 B NON-EXEMPT C.S. 14 0.750 C-G 18"-EBB-3 7-EBB-3-3 1200 470 A NON-EXEMPT C.S. 18 0.937 C-G F NON-EXEMPT C.S. 18 0.937 C-G ,14"-EBB-3 7-EBB-3-3 1200 470 G NON-EXEMPT C.S. 14 0.750 C-G C-613 H-11 NON-EXEMPT C-E-1 & 2 C-613 SR-26 NON-EXEMPT C-E-1 & 2 H NON-EXEMPT C.S. 14 0.750 C-G I NON-EXEMPT C.S. 14 0.750 C-G J NON-EXEMPT C.S. 14 0.750 C-G 36 NON-EXEMPT C.S 14 0.750 C-G 7-EBB 7 1200 470 C IWC-1220(d) C.S. 1 HY/VIS IWC-5000 6-013 SR-24 NON-EXEMPT C-E-1 & 3 C-613 SR-25 NON-EXEMPT C-E-1 & 2 A NON-EXEMPT C.S. 14 0.750 C-G 37 NON-EXEMPT C.S. 14 0.750 C-G 7-EBB-3-12 1200 470 38 NON-EXEMPT C.S. 14 0.750 C-G 18"-EBB-3 7-EBB-3-2 1200 470 32 NON-EXEMPT C.S. 18 0.937 C-G 31C IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 F IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 D NON-EXEMPT C.S. 18 0.937 C-G C NON-EXEMPT C.S. 18 0.937 c-G E IWC-1220(d) C.S. 1 HY/VIS IWC-5000 H IWC-1220 (d) C.S. 1 HY/VIS IWC-5000 31A IWC-1220 (d) C.S. 1 HY/VIS IWC-5000 31B IWC-1220 (d) C.S. 1 HY/VIS IWC-5000

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYSTEM MAIN FEEDWATER C1. ASS 2 . ISO NO.PM 207C,REV llP&ID NO. M-007, REV. 20 FAGE 2 OF 3 0 o CODE 2W zE$ z$ SECTION b ME11IOD AI,1DWING PIPE DATA Of 9 22t 2$ EXEMPTION INSPECTION STRESS LINE SPOOL PIECE W si gW WE1.D SUPPORT OR NRC SIZE THICKNESh (TABLE DATA g$f NUMBER NUMBER Q ob NUMBER NUMBER EXEMPTION MATERIAL (in.) (ie.) IWC-2600) POINTS REMARKS 18"-EBB-3 7-EBB-3-2 1200 470 C-612 SR-23 NON-EXEMPT C-E-2 (continued) (continued) G IWC-1220 (d) C.S. 1 HYWIS IWC-5000 C-612 SR-22 NON-EXEMPT C-E-2 C-612 H-8 NON-EXEMPT C-E-2 B NON-EXEMPT C.S. 18 0.937 C-G A NON-EXEMPT C.S. 18 0.937 C-G 38-4 NON-EXEMPT C.S. 18 0.937 C-G 7-EBB-3-15 1200 470 A NON-EXEMPT C.S. 18 0.342 C-G 38-1 NON-EXEMPT C.S. 18 0.937 C-G 7-EBB-3-1 1200 470 B NON-EXEMPT C.S. 18 0.937 C-G 29B IWC-1220(d) C.S. 2 HYWIS IWC-5000 A NON-EXEK/T C.S. 18 0.937 C-G 29A IWC-1220(d) C.S. 1 HY WIS IWC-5000 29 NON-EXEMPT C.S. 18 0.937 C-G 1 18"-EBD-12 7-EBD-12-11 1350 470 28 NON-EXEMPT C.S. 18 0.937 C-G 7-EBD-12-1 1350 470 ANCHOR 8169 NON-EXEMPT C-E-1 & 2 14"-EBB-3 7-EBB-3-13 1200 470 14 NON-EXEMPT C.S. 14 0.750 C-G 13 NON-EXEMPT C.S. 14 0.750 C-G 7-EBB-3-9 1200 470 A NON-EXEMPT C.S. 14 0.750 C-G C-613 SR-25 NON-EXEMPT C-E-1 & 2 C-613 SR-25 NON-EXEMPT C-E-1 & 2 B IWC-1220(d) C.S. 1 ItYWis IWC -5000 12 NON-EXEMPT C.S. 14 0.750 C-G 7-EBB-3-4 1200 470 J NON-EXEMPT C.S. 14 0.750 C-G I NON-EXEMPT C.S. 14 0.750 C-G H NON-EXEMPT C.S. le 0.750 C-G C-613 H-9 NON-EXEMPT C-E-1 & 2 C-613 SR-26 NON-EXEMPT C-E-1 & 2 G NON-EXEMPT C.S. 14 0.750 C-C 18"-EBB-3 7-EBB-3-4 1200 470 F NON-EXEMPT C.S. 18 0.937 C-G A NON-EXEMPT C.S. 18 0.937 C-G 14"-EBB-3 7-EBB-3-4 1200 470 B NON-EXEMPT C.S. 14 0.750 C-G C-613 SR-26 NON-EXEMPT C-E-1 & 2 C-613 H-10 NON-EXEMPT C-E-1 & 2 C NON-EXEMPT C.S. 14 0.750 C-G D NON-EXEMPT C.S. 14 0.750 C-G E NON-EXEMPT C.S. 14 0.750 C-G 9 NON-EXEMPT C.S. 14 0.750 C-G l

TECO/ DAVIS-BESSE/ UNIT 1 WELD St31 MARY SilEFT - TABLE 1 SYSTEM MAIN FEEDWATER C1. ASS 2 . ISO NOPM 207C,REV.llP&lD NO. M 007, REV.20 PAGE 3 OF 3 o CODE ZW SECTION ME1110D N$ 2 ALLOWING PIPE DATA OF 2 $2 $ EXEMFFION INSPECTION bTRESS gWg 9 LINE SPOOL PIECE g WELD SUPPORT OR NRC SIZE THICKNESb (TABLE DATA NUMBER NUMBER QoN Q NUMBER NUMBER EXEMPTION MATERIAL (in.) (im.) IWC-2600) POINTS REMARKS 14"-EBB-3 7-EBB-3-10 -1200 470 C IWC-1220(d) C.S. 1 HY/VIS IWC-5000 (continued) C-613 SR-25 NON-EXEMPT C-E-1 & 2 C-613 SR-24 NON-EXEMPT C-E-1 & 2 A NOF-EXEMPT C.S. 14 0.750 C-G 10 NON-EXEMPT C.S. 14 0.750 C-G 7-EBB-3-14 1200 470 11 NON-EXEMPT C.S. 14 0.750 C-G li"-EBB-3 7-EBB-3-5 1200 470 0 NON-EXEMPT C.S. 18 0.937 C-G 7B IWC-1220(d) C.S. 1 HY/VIS IWC-5000 7A IWC-1220(d) C.S. 1 HY/VIS IWC-5000 G IWC-1220 (d) C.S. HY/VIS IWC-5000 F IWC-1220(d) C.S. 1 HY/VIS IWC-5000 E IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 7C IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 7D IWC-1220(d) C.S. 3/4 HY/VIS IWC-5000 D NON-EXEMPT C.S. 18 0.937 C-G C NON-EXEMPT C.S. 18 0.937 C-G C-612 H-7 NON-EXEMPT C-E-2 C-612 SR-21 NON-EXEMPT C-E-2 C-612 SR-20 NON-EXEMPT C-E-2 C-612 H-6 NON-EXEMPT C-E-2 B NON-EXEMPT C.S. 18 0.937 C-G A NON-EXEMPT C.S. 18 0.937 C-G 37-4 NON-EXEMPT C.S. 18 0.937 C-G 7-EBB-3-16 1200 470 A NON-EXDtPT C.S. 18 0.842 C-G 7-EBB-3-6 1200 470 37-1 NON-EXEMPT C.S. 18 0.937 C-G A NON-EXEMPT C.S. 18 0.937 C-G SC IWC-1220(d) C.S. 2 HY/VIS IWC-5000 B NON-EXEMPT C.S. 18 0.937 C-G C IWC-1200(d) C.S. 1 HY/VIS IWC-5000 ) 58 IWC-1220(d) C.S. 1 HY/VIS IWC-5000 j 5E IWC-1220(d) C.S. 1 HY/VIS IWC-5000 SA IWC-1220(d) C.S. 1 HY/VIS IWC-5000 SD IWC-1220(d) C.S. 1 HY/VIS IWC-5000 18"-EBD-12 7-EBD-12-12 1350 470 4 NON-EXEMPT C.S. 18 0.937 C-G - 7-EBD-12-13 1350 470 ANCHOR 6171 NON-EXEMPT C-E-1 & 2

G G 1 C C %EN %EN F 0CO 0CO 2AI 2AI O Z FT ,FT E E ,RC RC S S C S S C SUU SUU I I A I I A I SP I SB V V F V V F V T V T 1 / / R / / R /DS /DS Y Y U Y Y U YNB YNB H If S H H S I AO HAO I E GA 1 1 2 1 1 2 1 1 P Y X X X X X X X X E E E E E E E E 0 X G G G G G G G G 2 C C q C C C C C V 1 E 0 R 6 - s r N e We O ngF n 7 I i n e 0 T li sg C de 0 N ruvm U ell a M F t cae anvt O. M wi s E d n N T edoo S enit D Y f at l S a2. nml1 r i oo6 o P ars t Mfi & a l 1 l. S S SAT V ETN 2 RAI E TDO 1E R, S P L TB C IA 7 NT 0 -KS) 2 6 5 2 6 5 7 7 U 2 CS. l e 4 7 7 4 7 7 3 3 / - lei E M iN( 8 0 3 8 0 3 9 9 T ST P 0 1 0 0 1 0 0 O SE EE O. l Bi N A S T 8 8 0 8 8 0 8 8 S O A E )a. Zi 1 2 4 1 2 4 1 1 IY S D I ( VR I S AA E P DM I L P /M O 2 A C U I S. S. S. S. S. S. S. S. R E S ET C C C C C C C C T D S A L S W E A W LC R EB MU N TR O PPU S R DE LB EM HU B C D B C D D 5 N l E 5 R C 1 6 ER E IE 1 6 T P 3 B A 3 3 LM B W OU B B B D ON E B B E P E E E S 7 F 7 7 N IA M R 3 EE B B N M AM BE E U I T N 8 S 1 YS

TECO/ DAVIS-BESSE AJNIT 1 WatLD

SUMMARY

SliEET - TABLE 1 SYSTEM MAKE-UP WATER TREATMENT CLASS 2 . ISO NO.f M 210E,REV.6 P&ID NO. M-010B, REV. 18 PAGE 1 OF 1 o o CODE 8d SECTION ME11tOD z4 ALIAWINO PIPE DATA OP zO $ 0e EXEMPTION INSPEC% ION STRESS s LINE SPOOL PIECE y W 3W W FI S) SUPPORT OR NRC SIZE TliaCKNESS (TABLE DATA NUMBER NUMBER cof no NUR ~ R NUM BER EXEMPTION MATERIAL (ia.) (6m.) IWC-2600) POINTS REMARKS 12 4"-HCB-23 108-liCB-23-1 150 150 ALL ALL s.s. 4 0.120 HY/VIS IWC-5000 g g) W 20 4"-HCD-4 10B-HCD-4-30 153 150 24 S.S. 4 0.120 HY/VIS IWC-5000 g,7c,122a -me 1.c-5000 ,m.oR m,

1 SK F R O A 0 0 M 0 0 E o 0 0 R 5 5 3_ c c C 1 w W I I tc S A S AST P ETN RAI TDO S P 8 1 1 N ) D O 0 Y O IE0 E H TL6 R TFCB2 S S OEA-I I E V V PTC M S(W / / 8 N Y Y 0 I ( H H 1 0 S SE M 0 0 N ). 2 2 Kni 1 1 C( O l 0 0 l i N T E D A Z )n. 4 4 I l T Sil a A P D 3 R L P A V 1 P I E R R, E T H A S. S. 1 0 M S S E 1 1 L 2 B TA I T M N P. 3 ) g U O N N 0 0 0 / T N N NI G O 2 2 OCI 2 2 E E EOITRT S E O DI W INP 1 1 1 S i I CELERE E l S T Q S OCOM M B LXOX - Y S AE E S lt A 3, 3, I VA M g DM 2 /U OS t C a ED S TR t T L S RE s E A OB PM R W L P O C U U H SN c L N L A A l t DE L LB L EM 2 A WUN bh o 0 S 5 o2E$W O i 1 2gyA 1_ T d$MUf N o;c gw o 0 0 E 5 5 M z2ga 1 1 TAER 1 2 T E C 5 3 R En 1 2 t E I E P B D B TA LM c C W OU H H ON n B P P o 0 S U t 1 EKA M 3 5 2 w 1 t C "n 3 N D n M c I y-Si LU u --. N Y 4 4 S

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TAllLE 1 SYSTEM HYDROGEN DILUTION C1. ASS 2 ISO NO. PM 229,REV.7 P&lD NO. ' PAGE 1 OF 2 -O 9 18 O O CODE 3$ SECTION METif0D 2 $" o 2h 2I ALLOWING PIPE DATA OF 9M EXEMI" TION INSPECTION STRESS LINE SPOOL PIECE g ad yg WELD SUPPORT OR NRC SIZE THICKNESh (TABLE DATA NUMBEH NUMBER Q O n. 00 NUMBER NUMBER EXEMPTION MATERIAL I m. ) (in.) IWC-2600) POINTS REMARKS 4"-HBB-16 29-HBB-16-2 >45 >264 ALL ALL IWC-1220 Lb), (d) C.S. 4 0.237 HY/VIS IWC-5000 29-HBB-16-3 >45 >264 ALL ALL IWC-1220(b),(d) C.S. 4 0.237 IfY/VIS IWC-5000 29-HBB-16-4 >45 >264 ALL ALL IWC-1220(b),(d) C.S. 4 0.237 HY/VIS IWC-5000 4*-HBB-15 29-l!BB-15-3 >45 >264 ALL ALL IWC-1220(b),(d) C.S. 4 0.237 HY/VIS IWC-5000 29-HBB-15-2 >45 >264 ALL ALL IWC-1220(b),(d) C.S. 4 0.237 IfY/VIS IWC-5000 29-HBB-15-1 >45 >264 ALL ALL IWC-1220 (b), (d) C.S. 4 0.237 HY/VIS IWC-5000 29-HBB-15-5 >45 >264 ALL ALL IWC-1220 t b), (d) C.S. 4 0.237 HY/VIS IWC-5000 29-HBB-15-4 >45 >264 ALL ALL IWC-1220(b),(d) C.S. 4 0.237 HY/VIS IWC-5000 4*-HBC-73 29-HBC-73-4 >45 >264 F IWC-1220 (b), (d) C.S. 4 0.237 liY/VIS IWC-5000

"-HCB-49 29-HCB-44-3

>45 >264 ALL ALL IWC-1220(b) S.S. 8 0.322 HY/VIS IWC-5000 I 29-HCB-44-2 >45 >264 ALL ALL IWC-1220(b) S.S. 8 0.322 HY/VIS IWC-5000 29-HCB-44-1 245 >264 3 IWC-1220(b) S.S. 8 0.322 HY/VIS IWC-5000 8"-HCB-43 29-HCB-43-FIB >45 >120 35A IWC-1220 (a), (b) S.S. 8 0.322 HY/VIS IWC-5000 29-HCB-43-F1 >45 >120 ALL ALL IWC-1220(a),(b) S.S. 8 0.322 MY/VIS IWC-5000 ll'-HBB-19 29-HBB-19-1 >45 >264 35 IWC-1220(b) C.S. 8 J.322 HY/VIS IWC-5000 e m

TECO/ DAVIS-oESSE/ UNIT 1 WELD SUMMAftY SilEET - TABLE 1 ' SYSTEM HYDROGEN DILUTION CLASS 2 . ISO NO. PM 229, REV. 7 P&lD NO.M-029A, REV. 19 M-029B, REV. 18 PAGE 2 OF 2 CODE Ew 0 SECTION MEnlOD zP$ z ALLOWING PIPE DATA OF oya o EXEMPTION INSPECTION STRESS hwE h LINE SPOOL PIECE OR NRC WELD SUPPORT SIZE THICKNESS (TABLE DATA NUMBER NUMBER oof a h , EXEMPTION MATERIAL (ia. ) (ia.) IWC-2600) POINTS REMARKS NUMBER NUMBER 8"-HBB-19 29-HBB-19-2 >45 >264 38 IWC-1220(b) C.S. 8 0.322 HY/VIS IWC-5000 (continued) 29-HBB-19-3 >45 >264 41 IWC-1220(b) C.S. 8 0.322 HY/VIS IWC-5000 29-HBB-19-4 >45 >264 44 IWC-1220(b) C.S. 8 0.322 HY/VIS IWC-5000 29-HBB-19-5 >45 >264 47 IWC-1220(b) C.S. 8 0.322 HY/VIS IWC-5000 E 29-118B-19-6 >45 >264 50 IWC-1220 (b) C.S. 8 0.322 HY/VIS IWC-5000 29-HBB-19-7 >45 >264 53 IWC-1220(b) C.S. 8 0.322 HY/VIS IWC-1000 29-MBB-19-8 >45 >264 56 IWC-1220(b) C.S. 8 0.322 HY/VIS IWC-5000 29-HBB-19-9 >45 >264 59 IWC-1220(b) C.S. 8 0.322 HY/VIS IWC-5000 i 29-HBB-19-10 >45 >264 62 IWC-1220(b) C.S. 8 0.322 HY/VIS IWC-5000 I l I e .I

..-s TECO/ DAVIS-BESSE/ UNIT 1 WEll)

SUMMARY

SIIEET - TABLE 2 SYSTEM HYDROGEN DILUTION CLASS 2 ISO NO. PM 229,REV. 7 P&ID NO. PAGE 1 OF 4 R FIPE DATA TillCK-STRESS LINE SPOOL PIECE WELD S!ZE NESS DATA NUMBER HUMBER NUMBER SUPPORT NUMBER MATERIAL (ia.) (ia. ) POIN11B SYSTEM FUNCTION X Y Z 4"-HBB-16 29-HBB-16-1 A C.S. 4 0.237 Hydrogen dilution HY/VIS EX 7 SURFACE system exhaust from containment vessel to containment vessel isolation valve. 28 B C.S. 4 0.237 HY/VIS EX 7 SURFACE 28 A C.S. 4 0.237 HY/VIS EX 7 SURFACE 4 B C.S. 4 0.237 HY/VIS EX 7 SURFACE C C.S. 4 0.237 HY/VIS EX 7 SURFACE D C.S. 4 0.237 HY/VIS EX 7 SURFACE E C.S. 4 0.237 HY/VIS EX 7 SURFACE 8*-18BB-19 29-11BB-19-1 A C.S. 8 0.322 Vacuum relief line HY/VIS EX 7 SURFACE from containment penetrations to motor operated valves. B C.S. 8 0.322 HY/VIS EX 7 SURFACE l 1 36 C.S. 8 0.322 HY/VIS EX 7 SURFACE 37 C.S. 8 0.322 IfY/VIS EX 7 SURFACE i 29-HBB-19-2 A C.S. 8 0.322 itY/VIS EX 7 SURFACE B C.S. 8 0.322 HY/VIS E1 7 ' SURFACE .9

we4 u . -. _. ~.,. w-TECO/ DAVIS-EESSE/ UNIT 1 WELD

SUMMARY

TET - TABLE 2 SYSTEM HYDROGEN DILUTION CLASS 2 ISO NO. PM 229,REV. 7 FalD NO. M-029A, REV. 19 PAGE 2 OF 4 M-029B, REV. 18 PIPE DATA THICK-STRESS LINE SPOOL PRECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (in.) (u.) POINTS SYaTTEM FUNCTION K Y Z C"-HBB-19 29-HB8-19-2 39 C.S. 8 0.322 Vacuum relief line MY/VIS EY 7 SURFACE from containment (continued) (continued) penetrations to motor operated valves. 40 C.S. 8 0.322 HY/VIS EX 7 SURFACE 29-HBB-19-3 A C.S. 8 0.322 dY/VIS EI 7 SURFACE B C.S. 8 0.322 NY/VIS EX 7 SURFACE 42 C.S. 8 0.322 HY/VIS EX 7 SURFACE 43 C.S. 8 o.322 NY/vrS Ex 7 SuRraCE 29-H88-19-4 A C.S. 8 0.322 HY/VIS EX 7 SURFACE e C.S. 8 o.322 HY/vr5 Ex 7 SUmfaCE t 45 C.S. 8 0.322 HY/VIS EI 7 SURFACE 46 C.S. 8 0.322 HY/vrS Ex 7 SUnraCE 29-HBB-19-5 A C.S. 8 0.322 NY/VIS EX 7 SURFACE B C.S. 8 o.322 NY/vis Ex 7 SUmraCE 48 C.S. 8 o.322 HY/vIS Ex 7 SumFACE 49 C.S. 8 o.322 HY/vIS Ex 7 SUmFACE

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM HYDROGEN DILUTION C1. ASS 2 ISO NO. PM 229,REV 7 P&lD NO. M-023A, REV. 19 PAGE 3 OF 4 M-029B, REV. 18 FIPE DATA THICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (as ) (um.) POINTS SYSTEM FUNCTION X Y Z f,"-HBB-19 29-hBB-19-6 A C.S. 8 0.322 Vacuum relief line HY,VIS EX 7 SURFACE (continued) frosa containment penetrations to notor operated valves. B C.S. 8 0.322 HY/VIS EX 7 SURFACE l 51 C.S. 8 0.322 HY/VIS EX 7 SURFACE 52 C.S. 8 0.322 HY/VIS EX 7 SURFACE 29-HBB-19-7 A C.S. 8 0.322 HY/VIS EX 7 SURFACE B C.S. 8 0.322 HY/VIS EX 7 SURFACE 54 C.S. 8 0.322 uY/VIS EX 7 SURFACE $5 C.S. 8 0.322 HY/VIS EX 7 SURFACE 29-HBB-19-8 A C.S. 8 0.322 HY/VIS EX 7 SURFACE B C.S. 8 0.322 HY/yIS EX 7 SURFACE 57 C.S. 8 0.322 HY/VIS EX 7 SURFACE 58 C.S. 8 0.322 HY/VIS EX 7 SURFACE 29-HBB-19-9 A C.S. 8 0.322 HY/VIS EX 7 SURFACE B C.S. 8 0.322 HY/VIS EX 7 SUEFACE i e

l l ll' lI h 0 4 F O Z E E E E E E C C C C C C A A A A A A 4 F F F F F F R R R R R R U U U U U U E S S S S S S GA 7 7 7 7 7 7 P Y X X X X X X E E E E E E S S S S S S 99 I I I I I I 11 1 V V V V V V / / / / / / Y Y Y Y Y Y H H H H H H VV EE RR ro N t AB O e o 99 I n m. 22 T i t C l nos 00 N et e U f m v MM F ensl ii na O M l aov E eti N T rntd S oae D Y mcrt l S u t a a umer cone P arep Vf po 7 S S SAT ETN 2 RAI V 1L R, IDO r'l P E E B TA 9 IT 2 N 2 KS) U C S e. 2 2 2 2 2 2 /- M HIEi 2 2 2 2 2 2 ET P TN( 3 3 3 3 3 3 SL 0 0 0 0 0 0 SE O Eli N A BS T E )a. O A Zi SY S D I S( 8 8 8 8 8 8 I IR VA E P AM I D P L /M 2 A OU IR CS E E T S. S. S. S. S. S. YD S A C C C C C C L S M E A W L C R E B MU N T R O P P US R DE LB EM 0 1 3 4 WU 6 6 A B 6 6 N NO 0 I E 9) 1 T C - d U ER 9 e 9 L E 1 u 1 IP I B - n D LM B B i N ON il t B OU B n H P - o E S 9 9 G 2 (c 2 OR DYH ) R d 9 e EE 1 u B N - n M IM Bi E LU B t T N H n S - o Y

  • c S

8(

TECO/ DAVIS-BwSE/ UNIT 1 WELD SUMMAltY S!!EET - TABLE 1 SYFFEM PURIFICATION - R. C. LETDOWN CLASS 2 . ISO NO.PM 231A,Rev.5 FAID NO. M-031, Rev. 23 FAGE 1 OF 2 O O CODE z6 g a E sECnoN MEntOD H a z ALLOWING PIPE DATA OF O$$ 05 EXEMPTION INSPECTION STRESS LINE SPOOL PIECE g ha h2 $g WELD SUPPORT OR NRC BIZE THICKNES5 (TABLE DATA NUMBER NUMBER QOf QOh NUMBER NUMBER EXEMPTION MATERIAL ,m) (m) IWC-2600) POINTS REMARKS 51/ "-CCB-21 31-CCB-21-1 2500 600 ALL ALL IWC-1220 (d) S.S. 3 0.438 HY/VIS IWC-5000 2 31-CCB-21-2 2500 600 M.L ALL , IWC-1220 (d) 5.S. 3 0.438 HY/VIS IWC-5000 31-CCB-21-3 2500 600 ALL ALL IWC-1220 (d) S.S. 2 0.438 Nf/VIS IWC-5000 6"-CCB-21 31-CCB-21-4 2500 600 7 HON-EXEMPT S.S. 6 0.562 C-G Al IWC-1220 (d) S.S. 1 HY/VIS IWC-5000 7A IWC-1220 (d) S.S. Ih HY/VIS IWC-5000 A NON-EXEMPT S.S. 6 0.562 C-G 31-CCB-21 H-22 NON-EXEMPT C-E-2 31-CCB-21 H-9 NON-EXEMPT C-E-1 & 2 8 HOH-EXEMPT S.S. 6 0.562 C-G 31-CCB-21-5 2500 600 8A IWC-1220 (d) S.S. 1% HY/VIS IWC-5000 A NON-EXEMPT 5.S, 6 0.562 C-G P 31-CCB-21-6 2500 600 9 NON-EXEMPT S.S. 6 0.562 C-G A NON-EXEMPT S.S. 6 0.562 C-c 31-CCB-21 H-12 NON-EXEMPF C-E-1 & 2 10 NON-EXEMPT S.S. 6 0.562 C-G 31-CCB-21-7 2500 600 A NON-EXEMPT S.S. 6 0.562 C-G ANQlOR 8252 NON-EXEMPT C-E-1 & 2 11 NON-EXEMPT S.S. 6 0.562 C-G 31-CCB-21-8 2500 600 A NON-EXEMPT S.S. 6 0.562 C-G 31-CCB-21 H-13 NON-EXEMPT C-E-1 & 2 12 NON-EXD(PT S.S. 6 0.562 C-G 31-CCB-21-9 2500 600 A NON-EXEMPT S.S. 6 0.562 C-G 31-CCB-21 H-10 NON-EXEMPT C-E-1 & 2 13 NON-EXEMPT S.S. 6 0.562 C-G w.

TECO/ DAVIS-B. E/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 CYSTEM PURIFICATION - R.C. LETDOWN CLASS 2 ISO NO.PM 231A.REV.5 P&lD NO. M-031,'REV. 23 P4GE 2 OF 2 n o CODE ZW Z SECTION ME1110D zE b Oy$ 2O$ EX EMPTION INSPECTION STRESS ALLOWING PIPE DATA OP LINE SPOOL PIECE Ew$ Ew6 WELD SUPPORT OR NRC SIZE '!111CKNES5 (TABLE DATA NUMBER NUMBER $$f NOh NUM BER NUMBER EXEMPTION MATERIAL la) (a) IWC-2600) POINTS REMARKS

  1. ?-CCB-21 31-CCB-21-10 2500 600 A

NON-EXEMPT S.S. 6 0.562 C-C (continued) 31-CCB-21 H-14 NON-EXEMPT C-E-1 & 2 14 NOh-FIEMPT S.S. 6 c.562 C-G 31-CCB-21-11 2500 600 A NON-EXEMPT S.S. 6 0.562 C-G 31-CCB-21 H-ll NON-EXEMPT C-E-1 & 2 31-CCB-21 H-15 NON-EXEMPT C-E-1 & 2 Al IWC-1220 (d) 5.S. 3/4 HY/VIS IWC-5000 B NON-EXEMPT S.S. 6 0.562 C-G 21/ -CCB-21 31-CCB-21-12 2500 600 ALL ALL IWC-1220 (d) S.S. 2 0.375 HY MIS IWC-5000 2 31-CCB-21-13 2500 600 ALL ALL IWC-1220 (d) s.S. 2% 0.375 HY/VIS IWC-5000 31-CCB-21-14A 2500 600 ALL ALL IWC-1220 (d) s.S. 2% 0.375 HY/VIS IWC-5000 31-CCB-21-14 2500 600 ALL ALL IWC-1220 (d) S.S. 2% 0.375 Hr/VIS IWC-5000 21/ -CCB-4 31-CCB-4-1 2500 600 ALL ALL IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 31-CCB-4-2 2500 600 ALL ALL IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 t y 4

o s TECO/ DAVIS-.SSE/ UNIT 1 WELD

SUMMARY

SiiEt.T - TABLE I SYSTEM MAKE-UP AND PURIFICATION CLASS ~! . ISO NO, PM 231B,REV.9 P&tD NO. M-031, REV.23 PAGE1 OF 1 o o CODE z 'a8 2 SECTION zE E ME11tOD oj$ z$ ALLOWING PIPE DATA OP h sd O"hg WELD SUPPORT OR NRC SIZE TillCKNESS (TABLE DATA o EXEMPTION INSPECTION STRESS LINE SPOOL PIECE NUMBER NUMBER Qok QQh NUMBER NUMBER EXEMPTION MATERIAL (in.) (in.) IWC-2600) POINTS REMARKS 2%"-CCB-21 31-CCB-21-14 2500 600 31-CCB-21 u-1 IWC-1220(d) Hv/VIS IWC-5000 31-CCB-21-15 2500 600 AIL ALL IWC-1220(d) s,s. 25 0.375 HY/VIS IWC-5000 2%"-CCB-9 31-CCB-21-16 2500 300 3 IWC-1220(d) S.s. 2 0.375 HY/VIS IWC-5000 31-CCB-9-1 2500 300 UK210R 8173 IWC-1220(d) HY/VIS IWC 5000 I 4

TECO/ DAVIS odSSE/ UNIT 1 WELD

SUMMARY

SliEET - TABLE 1 9 SYSTEM MAKE UP AND PURIFICATION CLASS 2 . ISO NO. PM 231C,REV.7 P&ID No, M-031, REV. 23 PAGE 1 OF 1 o o CODE zW Z SECTION METHOD zE$ zE A1. LOWING PIPE DATA OP 4 c4g3 og EXEMPTION INSPECTION STRESS LINE SPOOL PIECE yWW gg WELD SUPPORT OR NRC SIZE TitiCKNESh (TABLE DATA NUMBER - NUM BER coE ao NUM BER NUMBER EXEMPTION MATERIAL (in.) (in.) IWC-2600) POINTS REMARKS 20-CCB-13 31-CCB-13-1 3050 200 ALL ALL IWC-1220(d) s,s. 2 0.342 HY/VIs IWC-5000 2 "-CCB-13 31-CCB-13-2 3050 200 ALL ALL IWC-1220(d) s,s. 2 0.375 HY/VIs IWC-5000 31-CCB-13-F1 3050 200 86 IWC-1220(d) s.s. 2 0.375 HY/VIs IWC-5000 31-CCB-13-F2 3050 200 87 IWC-1220(d) s.s. 2% 0.375 tiY/VIs IWC-5000 31-CCB-13-2A 3050 200 ALL ALL IWC-1220(d) s.s. 2 0.375 HY/VIs IWC-5000 31-CCB-13-5 3050 200 ALL ALL IWC-1220(d) s.s. 2 0.375 HY/VIs IWC-5000 31-CBB-13-4A 3050 200 ALL ALL IWC-1220(d) s.s. 2 0.375 HY/VIs IWC-h000 31-CBB-13-F3 3050 200 ALL ALL IWC-1220(d) s.s. 2 0.375 HY/VIs IWC-5000 s l 31-CBB-13-F4 3050 200 ALL ALL IWC-1220(d) s.s. 2 0.375 HY/VIs IWC-5000 31-CCB-13-3 3050 200 ALL ALL IWC-1240(d) s s. 2 0.375 HY/VIs IWC-5000 31-CBB-13-4 3050 200 ALL ALL IWC-1220 M) s.s. 2 0.375 HY/VIs IWC-5000 'I G e

I TECO/ DAVIS - SSE/ UNIT 1 WELD

SUMMARY

Sl(EET - TABLE 1 SYSTEM MAKE-UP t. PURIFICATION CI.AC 2 . ISO NO.PM 231D,REV.11 P&lD NO. M-031, REV.23 FAGE 1 OF 2 O O CODE 2W 2 SECTION WETHOD gj$ 2 5 ALLOW LNG PhrE DATA OIP 2 g g EAEMPTION INSPECTION STRESS LINE SPOOL PIECE

  • WW gg WELD SUPPORT OR NRC SIZE THICKNESS (TABLE DATA NUMBER HUMBER QOf QOh NUM BER NUMBER EXEMPTION MATERIAI.

On ) (us.) IWC-2600) POINTS REMARKS 2%"-HCC-36 31-HCC-36-1 220 280 ALL ALL IWC-1220 (d) 2% 0.120 HY/VIS IWC-5000 s,s, 31-HCC-36-2 220 280 ALL ALI. IWC-1220 (d) S.S. 2% 0.120 HY/VIS IWC-5000 31-IICC-36-3 220 280 ALL ALL IE.-1220 (d) s,s, 2 0.120 HY/VIS IWC-5000 31-tKX 4 220 280 ALL ALL IWC-1220 (d) S.S. 2 0.120 HY/VIS IWC-5000 1 31-HCC-36-5 220 280 ALL ALL IWC-1220 (d) s,s, 2 0.120 HY/VIS IWC-5000 1 31-HCC-36-6 220 280 ALL ALL IWC-1220 (d) s,s, 2 0.120 HY/VIS IWC-5000 I 31-HCC-36-7 220 280 ALL ALL IWC-1220 (d) s,s, 2 0.120 HY/VIS IWC-5000 1 31-itCC-36-8 220 280 ALL ALL IWC-1220 (d) s,s, 2 0.120 HY/VIS IWC-5000 l 31-HCC-36-9 220 280 ALL ALL IWC-1220 (d) s,s, 2'a 0.120 HY/VIS IWC-5000 2 -CCB-7 31-GCB-7-2 300 350 ALL ALL IWC-1220 (d) s,s, 2 0.203 HY/VIS IWC-5000 31-cCa-7-1 200 350 ALL ALL IWC-1220 (d) s,s, 2 0.203 HY/VIS IWC-5000 3"-CCa-15 31-CCs-15-5/5A p 3050 200 ALL ALL IWC-1220 (d) s.S. 3 0.438 ftY/VIS IWC-5000 l 2%"-CCa-13 31-CCn-13-5A 3050 200 ALL ALL IWC-1220 (d) s 3, 2 0.375 HY/VIS IWC-5000 31-CrB-13-6 3050 200 ALL ALL IWC-1220 (d) s,s, 2 0.375 IIY/VIS IWC-5000 I 31-CCn-13-7 3050 200 ALL - 1 ALL IWC-1220 (d) s,s, 2% 1 0.375 HY/VIS IWC-5000 e i t

~ s TECO/ DAVIS. SSE/ UNIT 1 WELD

SUMMARY

SIIEET - TAB..S 1 SYSTEM MAKE-UP & PURIFICATION CLASS 2 . 40 NO. PM 231D,REV.llP&lD NO. M-031, REV. 23 PAGE 2 OF 2 o O CODE 2W Z SECTION E METHOD O j eSE$2) 2 ALLOWING PIPE D/TA OF c EXEMPTION INSPECTION STRESS gw0 gg WELD SUPPORT OR NRC SIZE Tli3CKNESS (TABLE DATA LINE SPOOL PIFEE NUMBER NUMBER cof co NUMBER NUMBER EXEMPTION MATERIAL (in ) be.) IWC-2600) POINTS REMARKS 2 "-CCB-13 31-CCB-13-8 3050 200 ALL ALL IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 (continued) 31-CCB-13-9 3050 200 ALL ALL IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 31-CCB-13-10 3050 200 ALL ALL IWC-1220 (d) S. EC. 2 0.375 HY/VIS IWC-5000 3\\*-CCB-3 31-CCB-3-1 3050 200 ALL ALL IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 31-CCB-3-2 3050 200 ALL ALL IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 4

TECO/ DAVIS..dSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYSTEM EMERGENCY CORE COOLING CLASS 2 , gSO No. PM 233A,ILV.10 P&lD NO. M-0 3 3, REv. 25 FAGE 1 CF 1 o O CODE zW Z SECTION METHOD 0y$ zE E ALLOWING PIPE DATA OF z) EXEMPTION INSPECTION STRESS y 0 LINE SPOOL PIECE gWW gg WELD SUPPORT OR NRC SIZE TitlCKNEsb (TABLE DATA NUMSER NUMBER Qof ao NUM BER NUMBER EXEMPTION MATERRAL (sa. ) (ie.) IWC-2600) POIN13 REMARKS 24'-HCB-2 Supplied with Tars 75 150 ALL ALL IWC-1220(a) s.s. 24 0.25 H)/VIS IWC-5000 33A-HCB-2-1 75 150 ALL ALL IWC-1220(a) s,s, 24 0.25 HY/VIS IWC-5000 33A-HCas-2-2 75 150 ALL ALL IWC-1220(a) s,s, 24 0.25 HY/VIS IWC-5000 14*-HCB-2 33A-HCB-2-3 75 150 ALL ALL IWC-1220(a) s,s, 14 0.188 NY/VIS IWC-5000 33A-HCB-2-4 75 150 ALL ALL IWC-1220(a) s,s, 14 0.188 HY/VIS IWC-5000 33A-HCB-2-5 75 150 7A IWC-1220(a) s,s, 14 0.188 HY/VIS IWC-5000 33A-HCB-2-6 75 150 ALL ALi. IWC-1220(a) s,3, 14 0.188 HY/VIS IWC-5000 33A-HCB-2-7 75 150 9 IWC-1220(a) s.s, 14 0.188 HY/VIS IWC-5000 33A-HCB-2-8 75 150 ALL ALL IWC-1220(a) s.s. 14 0.188 HY/VIS IWC-5000 33A-HCB-2-9 75 150 ALL ALL IWC-1220(a) s,s, 14 0.188 HY/VIS IWC-5000 33A-HCB-2-10 75 150 ALL ALL IWC-1220(a) s.S. 14 0.188 HY/V1S INC-5000 33A-HCB-2-11 75 150 ALL ALL IWC-1220(a) S.S. 14 0.188 HY/VIS IWC-5000 33A-HCB-2-12 75 150 ALL ALL IWC-1220(a) s.s. 14 0.188 HY/VIS IWC-5000 33A-HCB-2-13 75 150 ALL ALL IWC-1220 (a) s.s. 14 0.188 HY/VIS IWC-5000 33A-HCB-2-14 75 150 ALL ALL IWC-1220 (a) S.S. 14 0.183 HY/VIS IWC-5000 33A-HCB-2-15 75 150 ALL ALL IWC-1220(a) S.S. 14 0.188 EY/VIS IWC-5000 0 33A-HCB-2-16 75 150 ALL ALL IWC-1220(a) S.S. 14 0.188 HY/VIS IWC-5000

TECO/ DAVIS 6 sSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 2 SYSTEM EMERGENCY CORE COOLING C1. ASS . ISO NO.PM 233B,REV.12 P&lD NO. M-033, REV. 25 PAGE1 OF 2 o o CODE gy SECTION METlf0D x H :3 z ALLOWING PIPE DATA OF 2$$ 9 EXEMPTION INSPECTION bTRESS LINE SPOOL PIECE 3gg gg WELD SUPPOR OR NRC SIZE TH3CKNESb (TABLE DATA NUMBER HUMBER Q o n. QO NUMBER NUMBER EXEMPTION MATERIAL (en ) (im.) IWC-2600) POINTS REMARKS 14*-HCB-2 33A-HCB-2-18 75 150 ALL ALL IWC-1220 (a) S.S. 14 0.188 HY/VIS IWC-5000 33A-HCB-2-19 75 150 ALL ALL IWC-1220 (a) S.S. 14 0.188 HY/VIS IWC-5000 12"-GCB-8 33A-GCB-8-6B 300 350 E IWC-1220 (d) S.S. 1 HY/VIS IWC-5000 C IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 D IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 E IWC-1220 (d) S.S. 1 HY/VIS IWC-5000 6"-GCB-4 33A-GCB-4-6 450 350 F IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 34 IWC-1220 (d) S.S. 4 0.12 HY/VIS IWC-5000 24A IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 6"-GBC-4 33A-CBC-4-7 450 350 C IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 33A-GBC-4-8 450 350 C IWC-1220 (d) S.S. 2 !!Y/VIS IWC-5000 12"-HCB-1 33A-HCB-1-2 75 300 5B IWC-1220(d) S.S. 3/4 HY/VIS IWC-5000 H IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 SA IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 G IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 33A-HCB-1 H-1 NON-EXEMPT C-E-2 F IWC-1220 (d) S'S. 3/4 tiY/VIS IWC-5000 i 10*-HCB-3 33A-HCB-3-4 75 300 19A IWC-1223 (d; S.S. 3/4 HY/VIS. IWC-5000 3 3 A-liCB-3-6 75 300 C IWC-1220 (d: S.S. 2 HY/VIS IWC-5000 l 12"-GCB-8 33A-GCB-8-5 75 "00 E IWC-1220 (d) S.S. 1 HY/VIS IWC-0000 s 10A IWC-1220(d) S.S. 1 HY/VIS IWC-5000 108 IWC-1220(d) S.S. 1 HY/VIS IWC-5000 F IWC-1220(d) S.S. 2 HY/VIS IWC-5000 33A-GCB-8 H-2 NON-EXEMPT C-E-2 33A-GCB-8 H-3 NOJ-EXEMPT C-E-2 33A-GCB-8 H-4 NON-EXDEPF C-E-2 3)A-GCB-8 H-ll NON-EXEMPT ~ C-E-l&2 K IWC-1220(d) S.S. 1 HY/V1S IWC-5000

TECO/ DAVIS. 3SE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 1 SYSTEM EMERGENCY CORE COOLING 2 CLASS . ISO NOPM 233B',REV.12 PalD NO. M-033, REV. 25 PAGE 2 OF 2 O o CODE

r
g N

SEC;10N MEDIOD

c allow!NG PIPE DATA OF Q
  • Oh EXEMPTION INSPECTION 6 TRESS

$gh yW LINE SPOOL PIECE WELD SUPPORT OR NRC 'S!ZE THICKNESS (TABLE DATA NUMBER NUMBER Q o a. Oo NUMBER NUMBER EXEMPTION MATERIAL tan. ) (im.) IWC-1600) POINTS REMARKS 18"-GCB-8 33A-GCB-8-3 300 350 10A IWC-1220(d) S.S. 3/4 HY/VIS IWC-5000 33A-GCB-8 H-5 NON-EXEMPT C-E-2 33A-GCB-8 H-6 NON-EXEMPT C-E-2 C"-HCB-3 33A-HCB-3-1 75 300 17C IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 17D IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 G"-GCB-4 33A-GCB-4-3 450 350 C IWC-1220 (d) S.S. 1 HY/VIS IWC-5000 33A-GCB-4-2 450 350 31D IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 C IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 4"-GCB-2 33A-GCB-4-1 450 350 ALL ALL IWC-1220 (d) 3.S. 4 0.12 fry /VIS IWC-5000 14"-HCB-2 33A-HCB-2-17 75 150 ALL ALL IWC-1220 (a) S.S. 14 0.188 HY/VIS IWC-5000 18"-ISCB-1 33A-HCB-1-7 75 300 L IWC-1220 (d) S.S. 3/4 NY/VIS IWC-5000 9

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM EMERGENCT CORE COOLING CLASS 2 ISO NO. PM 2 3 3D, REV.12 P&ID NO. M-033, REV. 25 FAGE 1 OF 11 PIPE DATA THICK. STRESS IJNE 8 POOL P1ECE Fe'LD SIZE NESS DAT4 NUMBE9 NUMBER NUh.BER SUPPORT NUMBER MATERIAL (im.) (ie.) POINTS SYSTEM FUNCTION X Y Z IS'-HCB-1 33A-HCB-1-1 1 S.S. 18 0.188 Piping frosa emergency C-G EX 4 HY/VIS

sump, s8 A

S.S. 18 0.188 C-G EX 4 HY/VIS s8 6 S.S. 18 0.188 C-G EX 4 HY/VIS &8 B S.S. 18 0.188 C-G EX 4 HY/VIS s8 C S.S. 18 0.188 C-G EX 4 HY/VIS s8 D S.S. 18 0.188 C-G EX 4 HY/VIS s8 ANCHOR 441 C-E-EX 4 HY/VlS 1s2 F S.S. 18 0.188 C-G EX 4 HY/VIS s8 E S.S. 18 0.188 C-G EE 4 HY/VIS s8 2 S.S. la 0.188 C-G EX 4 HY/VIS s8 10*-CCB-8 33A-GCB-8-1 3 S.S. 18 0.312 Decay heat pump suction C-G EX 4 HY/VIS psnqing. &8 33A-GCB-8 H-1 C-E-EX 4 HY/VIS 1s2 ) B S.S. 18 0.312 C-G EX 4 HY/VIS &8 e A S.S. 18 0.312 C-G EX 4 HY/VIS s8 33A S.S. 18 0.312 C-G EX 4 HY/VIS s8 12"-GCB-8 33A-GCB-8-6B 33 S.S. 12 0.250 C-G EX 4 HYfVIS s8

~. TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SHEET - TABLE 2 SYSTEM EMERGENCY CORE COOLING CLASS 2 ISO NO. PM 23 3B,REV.12 P&ID NO. M-0 3 3, REv. 25 PAGE 2 OF11 PIPE DA1 A THICK. STRL98 EJNE SPOOL. PIECE - WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (ca.) (in.) POIN13 SYSTEM FUNCTION 1 Y Z 12*-GCB-8 33A-GCB-8-6B DCP S 8-12 0.25 Decay beat gxmp suction C-G EX 4 HY/VIS l (continued) (continued) gxamping. E8 B S.S. 12 0.25 C-G EX 4 NY/VIS &8 A S.S. 12 0.25 C-G EX 4 HY/VIS s8 33A-GCB-8 H-10 C-E-2 EX 4 NY/VIS 33A-GCB-8 H-9 C-E-EX 4 HY/VIS Is2 33A-GCB-8 H-8 C-E-3 EX 4 HY/VIS 33B S.S. 12 0.25 C-G EX 4 HY/VIS &8 33A-GCB-8-6A 338-1 S.S. 12 0.25 C-G EX 4 HY/VIS &8 ~ 33A-GCB-B H-7 C-E-2 EX 4 HY/VIS I 33A-GCB-8 H-15 C-E-EX 4 HY/VIS B S.S. 12 0.25 C-G EX 4 HY/VIS &8 TP S.S. 12 0.25 C-G EX 4 HY/VIS & I P 12 0.25 C-G EX 4 HY/VIS s8 33-GCL-8-2 B S.S. 12 0.25 C-G EX 4 HY/VIS ss A S.S. 12 0.25 C-G RI 4 NY/VIS &8 D

l TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYs17.M. EMERGENCY CORE COOLING CLASS 2 ISO NO.PA 23 3B,REV. 12 P&lD NO M- 033, REv. 25 FAGE 3 OF 11 PIPE DATA THICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (en.) (im.) POINTS SYSTEM FUNCTION X Y Z 6"-GCB-4 33A-GCB-4-5B 35 S.S. 6 0.134 H.P. injection pump C-G EX 4 HY/VIS suction piping. s8 ) 33A-GCB-4 H-3 C-E-2 EX 4 HY/VIS 33A-GCE-5 H-4 C-E-2 EX 4 HY/VIS 33A-GCB-5 H-5 C-E-2 EX 4 HY/VIS B S.S. 6 0.134 C4 EX 4 HY/VIS s8 35A S.S. 6 0.134 C-G EX 4 HY/VIS &8 ANCHOR 940 C-E-EX 4 HY/VIS 1s2 C S.S. 6 0.134 C-G EX 4 HY/VIS s8 D S.S. 6 0.134 C-G EX 4 HY/VIS s8 24 S.S. 6 0.134 C-G EX 4 HY/VIS l s8 33A-GCB-4-6 D S.S. 6 0.134 C-G EX 4 HY/VIS i s8 E S.S. 6 0.134 C-G EX 4 NY/VIS s8 C S.S. 6 0.134 C-G EX 4 HY/VIS &8 33A-GCB-4 H-6 C-E-EX 4 NY/VIS 1s2 1 33A-GCB-4 H-7 C-E-EX 4 HY/VIS = 1&2 E

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET '- TABLE 2 SYSTEM EMERGENCY CORE COOLING CLASS 2 ISO NO.PM 2 33B, REV.12 P&lD NO. H-0 3 3, REV. 25 PAGE 4 OF 11 PIPE DATA TillCK-ERESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER flUMBER NUMBER SUPPORT NUMBER MATERIAL On.) (in.) POINTS SYMEM FUNCTION X Y Z 0"-GCB-4 33A-{CB-4-6 B S.S. 6 0.134 II.P. injection pump C-G EX 4 HY/VIS (continued) (continu ed) suction piping. &8 A S.S. 6 0.134 C-G EX 4 HY/VIS &8 25 S.S. 6 0.134 C-G EX 4 HY/VIS &8 33A-GCB-4-7 26 S.S. 6 0.134 C-G EX-4 HY/VIS &8 A S.S. 6 0.134 C-G EX 4 HY/VIS &8 33A-GCB-4 H-8 C-E-EX 4 HY/VIS 1&2 B S.S. 6 0.134 C-G EX 4 HY/VIS &8 33A-GCB-4-8 A S.S. 6 0.134 C-G EX 4 HY/VIS &8 3 S.S. 6 0.134 C-G EX ( - HY/VIS &8 33A-CCB-4-9 A S.S. 6 0.134 C-G EX 4 HY/VIS &8 27 S.S. 6 0.134 C-G EX 4 HY/VIS &8 . I i 18"-HCB-1 33A-HCB-1-2 A S.S. 18 0.188 Piping from emergency C-G EX 4 HY/VIS sump. &8 SD S.S. 18 0.188 C-G EX 4 HY/VIS j &8 SC S.S. 18 0.188 C-G EX 4 HY/VIS &8

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSIT.M EMERGENCY CORE COOLING CLASS 2 ISO NO.PM 23 3B,I'EV.12 P&ID NO. M-033, REV. 25 PAGE 5 OF 11 PIPE DATA THICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUM BER NUMBER SUPPORT NUMBER MATERIAL (im.) (in. ) POINTS SYSTEM FUNCTION X Y Z 33A-HCB-1-2 C S.S. 18 0.188 Piping from emergency C-G EX 4 HY/VIS 1 *."-F (contanued) (continued) sump. &8 D S.S. 18 0.188 C-G EX 4 HY/VIS &8 14"-HCB-1 3JA-HCB-1-2 E* S.S. 14 0.188 C-C EX 4 HY/VIS &8 5 S.S. 14 0.188 C-G EX 4 HY/VIS &8 33A-HCB-1-3 4 S.S. 14 0.188 C-G EX 4, SURFACE 7&8 lt"-HCB-1 33A-HCB-1-3 A S.S. 18 0.188 C-G EX 4, SURFACE 768 B S.S. 18 0.188 C-G EX 4. SURFACE 7s8 lO"-HCB-3 33A-liCB-3-3 18 S.S. 10 0.165 From borated water C-G EX 4 HY/VIS storage tank discharge s8 piping to contsinnent spray pumps suction. D S.S. 10 0.165 C-G EX 4 ffY/VIS &8 A S.S-10 0.165 C-G EX 4 HY/VIS &8 B S.S. 10 0.165 C-G EX 4 HY/VIS &8 C S.S. 10 0.165 C-G EX 4 HY/VIS &8 33A-HCB-3 H-5 C-E-EX 4 HY/VIS 162 3

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SHEET - TABLE 2 SYSTEM EMERGENCY CORE COOLING CLASS 2 ISO NO. PM 2 3 3B, REV.12 P&Ip NO. !!-033 kJ!:V. 25 FACE 6 OF 11 PIPE DATA THICK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (in.) (ie.) POIN13 SYSTEM FUNCTION 1 Y Z 10"-HCB-3 33A-HCB-3-4 A S.S. 10 0.165 From borated water C-G EX 4 HY/VIS (continued) storage tank discharge s8 piping to containment spray pumps suction. 33A-HCB-3 H-4 - I C-E-EX 4 HY/VIS ls2 33A-HCB-3 H-3 C-E-EX 4 HY/VIS 1s2 B S.S. 10 0.165 C-E-EX 4 HY/VIS 1s2 C S.S. 10 0.165 C-E-EX 4 HY/VIS 1s2 33A-HCB-3 H-2 C-E-EX 4 HY/VIS 1s2 33A-HCB-3 H-1 C-E-EX 4 HY/VIS 1s2 D S.S. 10 0.165 C-G EX 4 HY/VIS s8 21A S.S. 10 0.165 C-G EX 4 HY/VIS s8 33A-HCB-3-5 21 S.S. 10 0.165 C-4 EX 4 HY/VIS s8 l A S.S. 8 0.148 C-G EX 4 HY/VIS s8 i 33A-liCB-3-6 A S.S. 8 0.148 C-G EX 4 HY/VIS s8 33A-HCB-3 H-8 C-E-EX 4 HY/VIS 1s2 B S.S. 8 0.148 C-G EX 4 HY/VIS &8

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SiiEET - TABLE 2 SYSTEM EMERGENCY CORE COOLING CLASS 2 ISO NO. PM 2 3 3B, REV.12 P&ID NO. M-033, REV. 25 PAGE 7 OF 11 PIPE DATA 1111CK-STRESS LINE SPOOL PIECE YELD SIZE NESS DATA NUMBER NUMBER Nt MBER SUPPORT NUMBER MATERIAL (ia.) (ia. ) POINTS SYSTEM FUNCTION X Y Z 10"-HCB-3 33A-HCB-3-7 A S.S. 8 0.148 From borated water C-G EX 4 HY/VIS (continued) storage tank discharge &8 piping to containment spray pumps suction. B S.S. 8 0.148 C-G EX 4 HY/VIS &8 12"-GCB-8 33A-GCB-8-5 H S.S. 12 0.25 Decay beat pump suc-C-G EX 8 SURFACE tion. I S.S. 12 0.25 C-G EX 8 SURFACE G S.S. 12 0.25 C-G EX 8 SURA. CE J S.S. 12 0.25 C-G EX 8 SURFACE D S.S. 12 0.25 C-G EX 8 SURFACE C S.S. 12 0.25 C-G EX 8 SURFACE B S.S. 12 0.25 C-G EX 8 SURFACE A S.S. 12 0.25 C-G EX 8 SURFACE j 33A-GCB-8-4 B S.S. 12 0.25 C-G EX 8 SURFACE A S.S. 12 0.25 C-G EX 8 SURFACE 33A-GCB-8-3 A 'S.S. 12 0.25 C-G EX 8 SURFACE 18"-GCB-8 33A-GCB-8-3 B S.S. 18 0.312 C-G EX 8 SURFACE i C S.S. 18 0.312 C-G EX 8 SURFACE

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM EMERGENCY CORE COOLING CLASS 2 ISO NO. PM 2 3 3B, REV. 12 F&lD NO. M-033, REV. 25 PAGE 8 OF 11 PIPE DATA THICK. STHESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER HUMBER NUMBER SUPPORT NUMBER MATERIAL On.) (in.) POINTS SYSTEM FUNCTION X Y Z 12"-CCB-7 33A-GCB-8-3 D S.S. 12 0.25 Decay heat pump suc-C-G EX 8 SURFACR tion. 11"-GCB-8 33A-GCB-8-3 10 S.S. 18 0.312 C-G EX 8 SURFACE G"-HCB-3 33A-HCB-3-2 B S.S. 8 0.148 From borated water C-G EX 4 HY/VIS storage tank discharge &8 piping to containment spray pumps suction. 33A-HCB-3 H-6 C-E-EX 4 HY/VIS 1&2 A S.S. 8 0.148 C-G EX 4 HY/VIS &8 3JA-!!CB-3-1 A S.S. 8 0.148 C-G EX 4 HY/VIS &8 17A S.S. 8 0.148 C-G EX 4 HY/VIS &8 33A-HCB-3 H-9 C-E-EX 4 HY/VIS 1&2 17B S.S. 8 0.148 C-G EX 4 HY/VIS &8 E S.S. 10 0.165 C-G - EX 4 HY/VIS &8 17 S.S. 10 0.165 C-G EX 4 HY/VIS &8 10"-HCB-3 33A-HCB-3-8 16 S.S. 10 0.165 C-G EX 4 HY/VIS &8 B S.S. 10 0.165 C-G EX 4 HY/VIS &8 C S.S. 10 0.165 C-G EX 4 BY/VIS &8 A S.S. 10 0.165 C-G EX 4 HY/VIS &8 10 S.S. 10 0.165 C-G EX-4 HY/VIA &8

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilELT - TABLE 2 EYSTEM EMERGENCY CORE COOLING CLASS 2 ISO NO. PM 2 33B, REV. 12 P&ID NO. M-033, REV. 25 PAGE 9 OF 11 PRE DATA TIIICK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (aa.) (.n. ) POINTS SYSTEM FUNCTION X Y Z 6"-GCB-4 33A-CCB-4-4 32 S.S. 6 0.134 H.P. Injection pump C-G EA 4 HY/VIS suction piping. &8 A S.S. 6 0.134 C-G EX 4 HY/VIS &8 33A-GCB-4-3 B S.S. 6 0.134 C-G EX 4 HY/VIS &8 A S.S. 6 0.134 C-G EX 4 HY/VIS &8 33A-GCB-4-2 31B S.S. 6 0.134 C-G EX 4 HY/VIS &8 31A S.S. 6 0.134 C-G EX 4 HY/VIS &8 33A-GCB-4 H-2 C-E-EY 4 HY/VIS 1&2 31C S.S. 6 0.134 C-G EX 4 HY/VIS &8 31 S.S. 6 0.134 C-G EX 4 HY/VIS &8 33A-GCD-4-1 30 S.S. 6 0.134 C-G EX 4 HY/VIS &8 C S.S. 6 0.134 C-5 EX 4 HY/VIS &8 B S.S. 6 0.134 C-G EX 4 HY/VIS &8 33A-GCB-4 H-1 C-E-EX 4 HY/VIS 1&2 A S.S. 6 0.134 C-G EX 4 HY/VIS &8 29 S.S. 6 0.134 C-G EX 4 HY/VIS &8 e \\

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SHEET - TABLE 2 i CYSTEM EMERGENCY CORE COOLING CLASS 2 ISO NO. PM 2 33 B, REV. 12PalD NO. M-033, REV. 25 FAGE 10 OF il PIPE DATA THICK-STRESS IJNE tiPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (ia.) (im.) POINTS SYSTEM FUNCTION X Y Z 18*-HCB-1 33A-HCB-1-7 B S.S. 18 0.188 Piping from emergency C-G EX 4 NY/VIS sump. &8 K S.S. 10 0.165 C-G EX 4 NY/VIS &8 ANCHOR 843 C-E-EX 4 HY/VIS 1&2 C S.S. 18 0.188 C-G EX 4 HY/VIS i &8 BC S.S. 18 0.188 C-C EX 4 HY/VIS &8 9 S.S. 18 0.188 C-G EX 4 HY/VIS &8 1 D S.S. 18 0.188 C-G EX 4 HY/VIS &8 E S.S. 18 0.188 C-G EX 4 HY/VIS &8 F S.S. 18 0.188 C-G EX 4 HY/VIC &8 33B-HCB-1 H-4 C-E-EX 4 HY/VIS 1&2 1 338-HCB-1 H-3 C-Ed EX 4 HY/VIS a 1&2 338-HCB-1 H-2 C-E-EX 4 HY/VIS 1&2 i

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM EMERGENCY CORE COOLING CLASS 2 ISO NO.PM 233B, REV. 12F&lD NO. M-033, REV. 25 FAGE 11 OF 11 PIPE DATA THICK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (ia.) (in. ) POINTS SYSTEM FUNCTION X Y Z 18"-HCB-1 33A-HCB-1-7 G S.S. 18 0.188 Piping from emergency C-G EX 4 HY/VIS (continued) (continued) sump. &8 H 'S.S-18 0.188 C-G EX 4 HY/VIS &8 I S.S. 14 0.188 C-G EX 4 HY/VIS &8 8 S.S. 14 0.188 C-G EX 4 HY/VIS &8 33A-HCB-1-6 7 S*S-14 0.188 C-G EX 4, SURFACE 168 A S S-18 0.188 C-G EX 4, SURFACE 7&S B S S-18 0.188 C-G EX 4, SURFACE j 7&8 l 5 7 1 4 4 8 e

TECO/ DAVIS SSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 1 SYSTEM DECAY !! EAT REMOVAL CLASS 2 . ISO NO. PM 23 3C,REV.5 P&ID NO. M-030, REV. 23 PAGE 1 OF 2 o o CODE Zg E SECTION ME7110D 2(gQ 9 z p z ALLOWING PIPE DATA OF EXEMPTION INSPECTION STRESS LINE SPOOL PIECE g se w g WELD SUPPORT OR NRC SIZE THICKNESb (TABLE DATA NUMBER NUMBER Q$f a h NUMBER NUMBER EXEMPTION MATERIAL [an.) (ie.) IWC-2600) POIN13 REMARKS 12*-CCB-7 33A-GCB-7-7 300 350 18B IWC-1220(d) S.S. 1 HY/VIS IWC-5000 IWC-1220(d) S.S. 2 HY/VIS IWC-5000 D IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 18A IWC-1220(2) S.S. 1 HY/VIS IWC-5000 33A-GCB-7-6 300 350 ANCHOR 945 NON-EXEMPT C-E-1 & 2 C IWC-1220(d) S.S. 3/4 HY/VIS IWC-5000 A IWC-1220(d) S.S. 2 HY/v!S IWC-5000 17A IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 17B IWC-1220(d) S.S. 2 HY/VIS IWC-5000 33A-GCB-7-5 300 350 33C-GCB-7 H-3 NON-EXEMPT C-E-2 D IWC-1220(d) S.S. 3/4 HY/VIS IWC-5000 33A-GCB-7-4 300 350 14P IWC-1220 (d) S.S. 25 FY/VIS IWC-5000 14E IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 C IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 B IWC-1220 (d) S.S. 4 0.12 HY/VIS IWC-5000 14C IWC-1220(d) S.S. 3/4 HY/VIS IWC-5000 i 14D IWC-1220(d) S.S. 3/4 HY/VIS IN-5000 33A-GCB-7-11 300 350 33C-GCB-7 H-9 NON-EXEMPT C-E-1 & 2 C IWC-1220 (d) S.S. 1 HY/VIS IWC-5000 B IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 33A-GCB-7-10 300 350 33C-GCB-7 H-7 NON-EXEMPT C-E-2 33C-GCB-7 H-8 NON-EXEMPT C-E-1 & 2 ANCHOR 844 NON-EXEMPT C-E-1 & 2 33A-GCB-7-9 300 350 33C-GCB-7 H-1 NON-EXEMPT C-E-1 & 2 33A-CCB-7-8 300 350 B IWC-1220 (d) F.S. 3/4 HY/VIS IWC-5000 D IWC-1220(d) S.S. 2 0.203 HY/VIS IWC-5000 21805 IWC-1220(d) S.S. 2 0.203 NY/VIS IWC-5000 21B IWC-1220 (d) S.S. 2 0.203 HY/VIS IWC-5000 21C IWC-1220(d) S.S. 2 33C-CCB-7 H-2 NON-EXDIPT 0.203 HY/VIS IWC-5000 33C-OCB-7 H-3 NON-EXEMPT ~ ~ C-E-2 33C-GCB-7 H-4 NON-EXEMPT ~ C-E-2 33C-GCB-7 H-5 NON-EXEMPT ~ ~ C-E-2 C-E-1 & 2 33C-GCB-7 H-6 NON-EXD(PT ~ ~ C-E-2

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE I LYbTEM DECAY HEAT REMOVAL CLASS 2 ISO NO. PM 233C,REV.5 P&lD NO. M-030, REV. 23 PAGE 2 OF 2 O O CODE ZM g SECTION METilOD 2$$zU$ z$ ALLOWING PIPE DATA OF 2 EXEMPTION INSPECTION STRESS Lade SPOOL PIECE ywW gg WELD SUPPORT OR NRC SIZE THICKNESh (TABLE DATA NUMBER NUMBER Qof QQ NUMBER NUMBER EXEMPTION MATERIAL (in.) (se.) IWC-2600) POINTS REMARKS 10*-HCB-24 33A-HCB-24-2 75 200 ALL ALL IWC-1220 (a) S.S. 10 0.165 HY/VIS IWC-5000 ANCHOR 8254 NON-EXEMPT C-E-1 & 2 33-HCB-24-1 75 200 ALL ALL IWC-1220(a) S.S. 10 0.165 HY/VIS IWC-5000

TECO/ DAVIS..SSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM DECAY HEAT REMOVAL CLASS 2 ISO NO. PM 233C,REV. 5 P&ID NO. M-030, REV. 23 FAGE 1 OF 5 - PIPE DATA THEK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (ia.) (hn.) POIN11B SYS'IEM FUNCTION K If 3 32"-GCB-7 33A-GCB-7-7 19 S.S. 12 0.250 From motorized valve C-G EX 8 SURFACE DH 11 to decay heat pump suction piping. G S.S. 12 0.250 C-G EX 8 SURFACE F. S.S. 12 0.250 C-G EX 8 SURFACE C S.S. 12 0.250 C-G EX 8 SURFACE B S.S. 12 0.250 C-G EX 8 SURFACE IBC S.S. 12 0.250 C-G EX 8 SURFACE k S.S. 12 0.250 C-G EX ') SURFACE 33A-GCB-7-6 18 S.S. 12 0.250 C-C EX 8 SURFACE 17CP S.S. 12 0.250 c-C EX 8 SURFACE D S.S. 12 0250 C-G EX 8 SURFACE B S.S. 12 0.250 C-G EX 8 SURFACE 9 0

TECO/ DAVIS bc;SSE/ UNIT 1 WELD

SUMMARY

SilEE"I' - TABLE 2 SYSTEM DECAY HEAT REMOVAL CLASS 2 ISO NO. PM 233C, REV. 5 P&ID NO. M-030, REV. 23. PAGE 2 OF 5 FIFE DATA THICK. FFRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER HUMBER NUMDER SUPPORT NUMBER MATERIAL (en.) (im.) POINTS SYSTEM FUNCTION X Y Z 12"-GCB-7 33A-GCB-7-6 17 S.S. 12 0.250 From motorized valve C-G EX 8 SURFACE (continued) (continued) DH 11 to decay heat j pump suction piping. i 10"-GCB-7 33A-GCB-7-6 H S.S. 10 0.250 C-G EX 8 SURFACE i G S.S. 10 0.250 C-G EX 8 SURFACE F S.S. 10 0.250 C-G EX 8 SURFACE E S.S. , 10 0.250 C-G EX 8 SURFACE 27 S.S. 10 0.250 C-G EX 8 SURFACE 12"-GCB-7 33A-GCB-7-5 16 s.S. 12 0.250 C-G EX 8 SURFACE l E S.S. 12 0.250 C-G EX 8 SURFACE 20 S.S. 12 0.250 C-G EX 8 SURFACE I C S.S. 12 0.250 C-G EX 8 SURFACE B S.S. 12 a.250 C-G EX 8 SURFACE e t - - ~

TECO/ DAVIS-B dE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 2 SYSTEM DECAY llEAT 'U:MOVAL CLASS 2 ISO NO. PM 2 33C, REV. 5 P&ID NO. M-030, REV. 23 PAGE 3 OF 5 PIPE DATA TIIICK-STRESS LINE SPOOt. PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (sa.) (ie. ) POINTS SYSTEM FUNCTION X Y Z 12"-GCB-7 33A-GCB-7-5 15A S.S. 12 0.250 From motorized valve C-G EX 8 SURFACE (continued) (continued) DH 11 to decay heat puar suction piping. 15 S.S. 12 0.250 C-G EX 8 SURFACE 14B S.S. 12 0.250 C-C EX 8 SURFACE 14A S.S. 12 0.250 C-G EX 8 SURFACE A S.S. 12 0.250 C-G EX 8 SURFACE 14 S.S. 12 0.250 C-G EX 8 SURFACE 8"-GCB-7 33A-GCB-7-1 9A S.S. 8 0.250 C-G EX 8 SURFACE C S.S. 8 0.250 C-G EX 8 SURFACE B S.S. 8 0.250 C-G, EX 0 SURFACE A S.S. 12 0.250 C-G EX 8 SURFACE 12"-GCB-7 33A-CCB-7-ll 24 S.S. 12 0.250 C-G EX 8 SURFACE C S.S. 12 0.250 C-G EX 8 SURFACE F S.S. 12 0.250 C-C EX 8 SURFACE

f Ps TECO/ DAVIS-L 3E/ UNIT 1 WELD

SUMMARY

SHEET - TABLE 2 SYSTEM DECAY HEAT REMOVAL CLASS 2 ISO NO. PM 2 3 3C, REV. 5 P&ID NO. M-030, REV. 23 FAGE 4 OF 5 PIPE DATA TillCK-ErrRESS LINE SPOOL PIECE WELD I IZE NESS DATA NUMBER HUMBER NUMBER SUPPORT NUMBER MATERIAL a.) On. ) POINTS SYSTEM FUNtmON X Y Z 12*-GCB-7 33A-GCB-7-ll E S.S. 12 0.250 Froma motorized valve C-G EX 8 SURFACE (continued) (continued') DH 11 to decay heat pump suction piping. D S.S. 12 0.250 C-G EX 8 SURFACE A S.S. 12 0.250 C-G EX 8 SURFACE 23A S.S. 12 0.250 C-G EX 8 SURFACE 33A-GCB-7-10 C S.S. 12 0.250 C-G EX 8 SURFAG B S.S. 12 0.250 C-G EX 8 SURFACE A S.S. 12 0.250 C-G EX 8 SURFACE 23 S.S. 12 0.250 C-C EX 8 SURFACE 33A-GCB-7-9 E S.S. 12 0.250 C-G EX 8 SURFACE D S.S. 12 0.250 C-G EX 8 SURFACE C S.S. 12 0.250 C-G EX 8 SURFACE 22A S.S. 12 0.250 C-G EX 8 SURFACE B S.S. 12 0.250 C-G EX 8 SURFACE

TECO/ DAVIS._JSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM DECAY HEAT REMOVAL CLASS 2 ISO NO. PM 2 33C, REV. 5 P&lD NO. M-030, REV. 23 PAGE 5 OF 5 PIPE DATA TilICK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL Co.) (in.) POINTS SYSTEM FUNCTION X Y Z 12"-GCB-7 33A-GCB-7-9 A S.S. 12 0.250 From motorized valve C-G EX 8 SURFACE (continueds (continued) DH 11 to decay heat Pug suction piping. 22 S.S. 12 0.250 C-G EX 8 SURFACE 33A-GCB-7-8 A S.S. 12 0.250 C-G EX 8 SURFACE C S.S. 12 0.250 C-G EX 8 SURFACE 21A S.S. 12 0.250 C-G EX 8 SURFACE 21 S.S. 12 0.250 C-G EX 8 SURFACE 10*-GCB-7 33A-GCB-7-8 F S.S. 10 0.250 C-G EX 8 SURFACE E S.S. 10 0.250 C-G EX 8 SURFACE 29 S.S. 10 0.250 C-G EX 8 SURFACE

TECO/ DAVIS.,SE/ UNIT 1 WEll)

SUMMARY

SilEET - TABLE I CYSTEM HIGH PRESSURE INJECTION CLASS 2 . ISO NO. PM2 33D,REV.10 PalD NO. M-033, REV. 25 PAGE 1 OF 3 g o CODE zw z SECTION METHOD zE$ zy E ALLOWING PIPE DATA OF ojw a EXEMNION INSPECTION STRESS LINE SPOOL PIECE hwN hg WELD SUPPORT OR NRC SI7E THICKNESH (TABLE DATA NUMBER NUMBER cof QQ NUMBER NUMBER EXEMPTION MATERIAL lm.) (ia.) IWC-2600) POINTS REMARKS 4"-HCB-2 33C-IICB-2-1 75 150 All All IWC-1220 (a), (d) S.S. 4 0.120 HY/VIS IWC-5000 33C-HCB-2-2 75 150 All All IWC-1220 (a), (d) S.S. 4 0.120 HY/VIS IWC-5000 33C-HCB-2-3 75 150 All All IWC-1220 (a), (d) S.S. 4 0.120 HY/VIS IWC-5000 33C-HCB-2-4 75 150 All All IWC-1220 (a), (d) S.S. 4 0.120 HY/VIS IWC-5000 4"-HCC-124 33C-HCC-124-5 IWC-1220 (a), (d) HY/VIS IWC-5000 4"-liCB-2 33C-HCB-2-5 75 150 All All IWC-1220 (a), (d) S.S. 4 0.120 HY/VIS IWC-5000 33C-HCB-2-6 75 150 All All IWC-1220 (a), (d) S.S. 4 0.120 HY/VIS IWC-5000 2:a*-CCB-2 33C-CCB-2-1 2000 300 All All IWC-1220 (d) S.S. 25 0.375 HY/VIS IWC-5000 33C-CCB-2-10 2000 300 All All IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-3 2000 300 All All IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-4 2000 300 All All IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-5 2000 300 All All IWC-1220 (d) S.S. 2% 0.375 HY/VIS IWC-5000 l i 33C-CCB-2-2 2000 300 All All IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-11 2000 300 All All IWC-1220 (d) S.S. 25 0.375 HY/VIS IWC-5000 4"-CCB-2 33C-CCB-2-6B 2000 300 All All IWC-1220 (d) S.S. 4 0.438 HY/VIS IWC-5000 l

e TECO/ DAVIS JSSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYSTEM HIGH PRESSURE INJECTION CLASS 2 . ISO NO.PM 233D,REV.10 P&ID NO. M-033, REV. 25 PAGE 2 OF 3 o o CODE xW SECTION MET 110D oj$ g gP ALLOWING PIPE DATA OF g o EX EMPTION INSPECTION STRESS LINE SPOOL PIECE hWW h WELD SUPPORT OR NRC SIZE TillCKNESh (TABLE DATA NUMBER NUMBER Qof a NUM BER NUMBER EXEMPTION MATERIAL ) (ie.) IWC-2600) POINTS REMARKS 4"-CCB-2 33C-CCB-2-6A 2000 300 All All IWC-1220 (d) S.S. 4 0.438 IW/VIS IWC-5000 (continued) 33C-CCB-2-7 2000 300 All All IWC-1220 (d) S.S. 4 0.438 IN/VIS IWC-5000 33C-CCB-2-8 2000 300 All All IWC-1220 (d) S.S. 4 0.438 HY/VIS IWC-5000 33C-B-2-9 2000 300 All All IWC-1220 (d) S.S. 4 0.438 IW/VIS IWC-5000 4"-CCB-18 33C-CCB-2-8 2000 300 All All IWC-1220 (d) s.S. 4 0.438 HY/VIS IWC-5000 4"-CCB-19 33C-CCB-19-4 3050 300 All All IWC-1220 (d) S.S. 4 0.438 HY/VIS IWC-5000 33C-CCB-19-3 3050 300 All All IWC-1220 (d) S.S. 4 0.438 HY/VIS IWC-5000 33C-CCB-19-2 3050 300 All All IWC-1220 (d) S.S. 4 0.438 HY/VIS IWC-5000 33C-CCB-19-1 3050 300 All All IWC-1220 (d) S.S. 4 0.438 HY/VIS IWC-5000 4"-CCB-2 33C-CCB-2-14 2000 300 All All IWC-1220 (d) S.S. 4 0.438 HY/VIS IWC-5000 33C-CCB-2-13 2000 300 All All IWC-1220 (d) S.S. 4 0.438 HY/VIS IWC-5000 33C-CCB-2-12 2000 300 All All IWC-1220 (d) S.S. 4 0.438 HY/VIS IWC-5000 3 3c-CrB-2-15 2000 300 All All IWC-1220 (d) S.S. 4 0.438 HY/VTS IWC-5000 ' 35"-CCB-2 33C-CCB+2-15 2000 300 All All IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-16 2000 300 All All IWC-1220 (d) 8.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-17 2000 300 All All IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000

TECO/ DAVIS- .SE/ UNIT 1 ~ WELD

SUMMARY

SilEET - TABLE I SYSTEM HIGli PRESSURE INJECTION CLASS 2 . ISO NO.PM 23 3D,REV.10P&lD NO. M-033, REV. 25 PAGE 3 OF 3 o% CODE o2W 2-SECTION gEh b METitOD 7 ALLOW LNG PIPE DATA OF gy$ g$ EXEMPTION INSPECTION STRESS LINE SPOOL P1ECE $gg pg WELD SUPPORT OR NRC SIZE THICKNESh (TABLE DATA NUMBER NUMBER Q Q a. QQ NUMBER NUM BER EXEMPTION MATERIAL (in.) (us.) IWC-2600) POINTS REMARKS 2 "-CCB-2 33C-CCB-2-18 2000 300 All All IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 (continued) 33C-CCB-2-19 2000 300 All All IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 3"-CCB-19 33C-CCB-19-4A 3050 300 All All IWC-1220 (d) S.S. 3 0.438 IIY/VIS IWC-5000 3"-CCB-12 33C-CCB-19-5A 3050 300 All All IWC-1220 (d) S.S. 3 0.438' HY/VIS IWC-5000 33C-CCB-12-2 3050 300 48 IWC-1220 (d) S.S. 3 0.438 HY/VIS IWC-5000 3 3C-CCB-J '.-3 3050 300 49 IWC-1220 (d) S.S. 3 0.438 HY/VIS IWC-5000 Anchor 853 IWC-1220 (d) HY/VIS IWC 4000 33C-CCB-12-4 3050 300 50 IWC-1220 id) S.S. 3 0.438 ffY/VIS IWC-5000 33C-CCB-12-5 3050 300 All All IWC-1220 (d) S.S. 3 0.438 HY/VIS IWC-5000 i 33C-CCB-12-F6 305G 300 All All IWC-1220 (d) S.S. 3 0.438 HY/VIS IWC-5000 3"-f!CC-91 33C-HCC-91-48 35 200 54F IWC-1220 (a),(d) S.S. 3 0.120 IfY/VIs IWC-5000 33C-HCC-91-5 35 200 Anchor fl90 IWC-1220 (a),(d) HY/VI. IWC-5000 I' i

TECO/ DAVIS.,SE/ UNIT 1 WELD SUMMAltY SilEET - TABLE I SYSTEM llIGI! PRESSURE It!JECTION CLASS 2 . ISO NO. PM 233E,REV. 8 P&ID NO. M-033, REV.25 PAGE 1 OF 2 d CODE oh I oZy 3 SECTION METIIOD i xE 2 245 ALLOWING PIPE DATA OF 9$:* 25E EXEMPTION INSPECTION STRESS LINE SPOOL PIECE yWU $gO 8 WELD SUPPORT OR NRC SIZE THICKNESS (TABLE DATA NUM BER NUM BER Qof QOh NUMBER NUMBER EXEMPTION MATERIAL (in. ) (in.) IWC-2600) POINTS REMARKS 2%*-CCB-2 33C-CCB-2-36 2000 300 ALL ALL IWC-1220 (d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-37 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-38 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-39 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-40 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-41 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-31 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-32 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-33 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-34 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWO-5000 33C-CCB-2-35 2000 300 ALL ALL IWC-1220(d) S.S. 25 0.375 HY/VIS. IWC-5000 33C-CCB-2-27 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-28 2000 300 ALL ALL IWC ~.220(d) S.S. 2 0.375 IIY/VIS IWC-5000 33C-CCB-2-29 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-30 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000

TECO/ DAVIS-L 3E/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYSTEM HIG!1 PRESSURE ItLTECTION CLASS 2 ISO NO. PM 233E, REV.St%ID NO. M-033, REV.25 PACE 2 OF 2 ch o$ 3# SECTION METitOD CODE 3 52 h ":)$2 h { b 2b 2 ALLownt4G PIPE DATA Olr ygh $gh EXEMNION INSPECTION STRESS LIN E SPOOL PIECE WELD SUPPORT CtNRC SIZE TillCKNESS (TABLE DATA NUMBER NUM BER Q O e. ooF NUMBEM NUMBER - EXEMPTION MATERIAL (a) (in.) IWC-2600) POINTS REMARKS 2 *-CCB-2 33C-CCB-2-20 2000 300 ALL ALI. IWC-1220(d) S.S. 2 0.375 HY/VIS IWr,*5000 (continued) 33C-CCB-2-21 2000 300 ALL ALL IWC-1220(d) S.S. 25 0.375 HY/VIS IWC-5000 310-CCB-2-22 2000 3" ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 [ 33C-CCB-2-23 2000 300 ALL ALL IWC-1220(d) SsS. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-24 2000 300 ALL ALL IWC-1220(d) S.S. 2\\ 0.375 HY/VIS IWC-5000 33C-CCB-2-25 2000 300 ALL ALL IWC-1220(d) S.S. 2 0.375 HY/VIS IWC-5000 33C-CCB-2-26 2000 300 ALL ALL IWC-1220 (d) S.S. 2\\ 0.375 HY/VIS IWC *'e3 i

TECO/ DAVIS-a..sSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYS IDI LOW PRESSURE INJECTION Ct. ASS 2 ISO NO. PM 233P REV.ll l'&lu No. M-033 REV.25 l*Aus 1 OF 6 0N CODE 03y 3d SECTION METilOD b zb z ALLOWING PIPE DATA OF 0$a 0$ EXEMPTION INSPECTION STRESS LINE SPOOL. PIECE mwW mW WELD SUPPORT OR NRC SIZE TlilCKNESS (TABLE DATA NUMRElt NUM BE tt $$f $0h l NUMBER NUMBER EXEMPTION MATERIAL, in.) (m.) IWC-2600) POINTS REMARKS 10bGCB-1 338-GCB-1-1 450 350 8 IWC-1220(d) S.S. 2 HY/VIS IWC-5000 i 338-GCB-1-2 450 350 33B-CCB-1 H-20 NON-EXEMPT C-E-l&2 33B-GCB-1 H-19 NON-EXEMPT C-E-l&2 338-GCB-1 H-18 HON-EXEMPT C-E-2 33B-GCB-1 H-17 HON-EXEMPT C-E-l&2 33B-GCB-1-3 450 350 338-GCB-1 H-22 NON-EXEMPT C-E-l&2 338-CCB-1 H-21 NON-EXEMPT C-E-2 338-GCB-1 H-33 NON-EXEMPT C-E-l&2 33B-GCB-1 H-34 NON-EXEMPT C-E-l&2 33B-GCB-1-3A 450 350 338-GCB-1 H-23 NON-EXEMPT C-E-2 338-GCB-1 H-24 NON-EXEMPT C-E-2 G IWC-1220(d) S.S. 3/4 HY/VIS IWC-5000 33B-GCB-1 H-26 NON-EXEMPT C-E-2 33B-GCB-1 H-25 NON-EXEMPT C-E-2 33B-GCB-1-4 450 350 33B-GCB-1 H-27 NON-EXEMPT C-E-l&2 P IWC-1220(d) S.S. 2 HY/VIS IWC-5000 6"-GCB-10 33B-GCB-1-5 450 350 33B-GCB-1 H-36 NON-EXEMPT C-E-2 338-GCB-1 H-31 NON-EXEMPT t'-E-2 i 33B-GCB-1-6 450 350 33B-GCB-10 H-35 NON-EXEMPT C-E-2 l 10"-GCB-10 33B-GCB-10-1 450 350 E IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 i F IWC-1220(d) S.S. 2 HY/VIS IWC-5000 G IWC-1220(d) S.S. 1 HY/VIS IWC-5000 20A IWC-1220 (d) S.S. 1 HY/VIS IWC-5000 20B IWC-1220(d) S.S. 1 HY/VIS IWC-5000 338-GCB-10 H-32 NON-EXEMPT C-E-l&2 33B-GCB-10 H-31 NON-EXEMPT C-E-1&2 338-GCB-10 H-3] NON-EXEMPT C-E-l&2 C IWC-1220(d) S.S. 1 HY/VIS IWC-5000

TECO/ DAVIS-SE/ UNIT 1 WELD SUMMAltY SilEET - TAllLE 1 ShlDI 14W PRESSURE INJECTION CLASS 2 ISO NO. PM 233F REV.11 P1ID NO. M-033 REV.25 pal;E 2 OF 6 oh CODE oZy Zd SECTION METHOD by ALLOWING PIPE DATA OF 2b 0$a 05W. EXEMPTION INSPECTION STRESS z 'a y rd d yW WELD SUProitT OR NRC SIZE PHICKNESS (TABLE DATA 5.IN E bPOOL PIECE D g3 $ f C2 o h NUMBElt NUMut.lt NUM BER NUMBER EXEMPTION MATERIAL [un.) (in.) IWC-2tsOC) POINTS REMARKS 10"-GCB-10 338-GCB-10-3 450 350 A IWC-1220 (d) S.S. 1 HY/VIS IWC-5000' (continued) 2 "-GCB-10 33B-GCB-10-3 450 350 ALL ALL IWC-122O(d) S S-2 0.203 HY/VIS IWC-5000 10"-GCB-10 33B-CCB-10-3 450 350 ~ ANChC* $63 NON-EXEMPT C-E-l&2 33B-CCB-lO-4 450 350 338-GCB-10 H-18 NON-EXEMPT C-E-2 33B-GCB-10 H-17 NON-EXEMPT C-E-2 33B-GCB-10-5 450 350 B IwC-1220 (d) S.S. 4 HY/VIS IWC-5000 24E IWC-1220(d) S.S. 1 HY/VIS IWC-5000 338-GCB-lO H-16 NON-EXEMPT C-E-l&2 338-GCB-10-6 450 350 33B-GCB-10 H-15 NON-EXEMPT C-E-2 33B-GCB-10 H-13 NON-EXEMPT C-E-2 33B-GCB-lO H-14 NON-EXEMPT C-E-2 33B-GCB-10 H-12 NON-EXEMPT C-E-l&2 33B-GCB-lO H-ll NON-EXEMPT C-E-2 338-GCB-10-8 450 350 33B-GCB-10 H-10 NON-EXEMPT C-E-l&2 338-GCB-lO H-9 NON-EXEMPT C-E-2 338-GCB-10-9 450 350 33B-GCB-lO H-8 NON-EXEMPT C-E-2 33B-GCB-10 H-6 NON-EXEMPT C-E-2 338-GCB-10 H-5 NON-EXEMPT C-E-2 i 338-GCB-lO H-4 NON-EXEMPT C-E-l&2 33B-GCB-lO-10 450 350 ANCHOR 864 NON-EXEMPT C-E-l&2 l 338-GCB-lO-11 450 350 33B-GCB-10 H-29 NON-EXEMPT A C-E-2 33B-GCB-10 H-28 NON-EXEMPT C-E-l&2 D IWC-1220(d) S S-3/4 HY/VIS IwC-5000 lO"-CCB-6 33C-CCB-6-10 2500 350 38 NON-EXEMPT S.S. 10 1.000 C-G A 'NON-EXEMPT S.S. 10 1.000' C-G. ~ B NON-EXEMPT S.S. 10 1.000 C-G C-NON-EXEMPT S.S 10 1.000 C-G^

TECO/ DAVIS u_SSE/ UNIT 1 WEi.D SUMMAltY SilEET - TABLE 1 SYsreal IAW PRESSURE INJECTION Cl.J SS 2 . ISO NO. PM 233F REV.11 l'alu NOM-033 REV.25 t*Am 3 OF 6 og cooE ozy 2 SECrtON METHOD 9)g E zb2 x ALI.OWING P1PE DATA OF S $ 'a ywU yWg EXEMPTION INSPECTION STRESS 1.IN E SPOOi, PIECE WELD SUPPORT OR NHC BIZE fHICKNESS (TABLE DATA QQk QQh NUMBER NLMtWM NUMBER NUMBER EXEMPTION MATERIAL .ia.) (in.) IWC-2600) POINTS REklARKS j 4"-GCB-2 33B-GCB-2-1 450 350 ALL ALL IWC-1220(d) S.S. 4 0.120 HY/VIS IWC-5000 f 33B-GCB-2-2 450 350 ALL ALL IW'l-1220(d) S.S. 4 0.120 HY/VIS IWC-5000 338-GCB-2-3 450 350 ALL ALL IWC-1220 (d) S S-4 0.120 HY/VIS IWC-5000 8"-GCB-10 33B-GCB-10-7 450 350 ANCHOR 865 NON-EXEMPT C-E-Is2 0"-HCB-9 338-HCB-9-1 200 200 9 IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 A IWC-1220 (a) S.S. 8 0.148 HY/VIS IWC-5000 8 IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 3"-HCB-36 33B-HCB-36-1 150 150 7 IWC-1220 (a) S.S. 8 0.148 HY/VIS IWC-5000 6C IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 6B IWC-1220 (a) S.S. 8 0.148 HY/VIS IWC-5000 ANCHOR 871 IWC-1220 (a) HY/VIS IWC-5000 6A IWC-1220(a) S.S. 8 0.148 isY/VIS IWC-5000 A IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 B IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 C IWC-1220(a) S.S. 3/4 HY/VIS IWC-5000 338-HCB-36 H-11 IWC-1220(a) HY/VIS IWC-5000 33B-HCB-36 H-10 IWC-1220(a) HY/VIS IWC-5000 s 338-HCB-36-2 150 150 16 IWC-1220(a) S 8-8 0.148 HY/VIS IWC-5000 E IWC-1220(a) S S-8 0.148 HY/VIS. IWC-5000 D IWC-1220(a) S S-8 0.148 IIY/VIS IWC-5000 3 C IWC-1220 (a) S S-8 0.148 HY/VIS IWC-5000 B IWC-1220 (a) S S-8 0.148 IIY/VIS IWC-5000 A IWC-1220(a) S S-8 0.148 !!Y/VIS IWC-5000 338-IICB-36 H-9 IWC-1220(a) HY/VIS IWC-5000 33B-HCB-36 H-8 IWC-1220 (a) HY/VIS IWC-5000 33B-HCB-36 H-7 IWC-1220(a) HY/VIS IWC-5000 338-HCB-36-3 150 150 5 IWC-1220 (a) S.S. 8 0.148' HY/VIS IWC-5000 A IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 338-HCB-36 H-6 IWC-1220(a) HY/VIS IWC-5000 B IWC-1220(a) S.S. 1 HY/VIS IWC-5000 C IWC-1220(a) S.S. 8 0.188 HY/VIS IWC-5000 L

TECO/ DAVIS u dSE/ UNIT l WELD SUMMAltY SilEET - TABLE I .m i'h.\\t IIM PRESSURE IIUECTION CLASS 2 ISO NO. PM 233F REv.ll l' alp NO.M-033 REV.25 l'AGls 4 O l' 6 o o CODE zW 2 TECTION METHOD o<b z$ zE E ALLOWING PtPE DATA OF m o EX EMPTION INSPECTION STRESS LINE SPOOt. PIECE EN$ EWO-WELD SUPPOttT OR Nhc SIZE THICKNESS (TABLE DATA N$f NOh .UM Belt NUMBER NUMBER NUMBER EXEMPTION MATERIAL [ia.) (in.) IWC-2600) POINTS REMARKS i $*-HCB-36 33B-HCB-36-4 150 150 4 IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 (continued) 33B-HCB-36 H-5 IWC-1220(a) HY/VIS IWC-5000 33B-HCB-36 H-4 IWC-1220(a) HY/VIS IWC-5000 ANCHOR 967 IWC-1220 (a) G IWC-1220(a) 8 8-HY/VIS IWC-5000 8; 0.148 HY/VIS IWC-5000 F IWC-1220 (a) S.S. 8 0.148 HY/VIS IWC-5000 E IWC-1220(a) 8 8* 8 0.148 HY/VIS IWC-5000 D IWC-1220(a) 88-3 0.148 HY/VIS IWC-5000 C IWC-1220 (a), (d) 8 8-3/4 HY/VIS IWC-5000 33B-HCB-ll H-3 IWC-1220(a),(d) B IWC-1220 (a), (d) 88-HY/VIS IWC-5000 3 HY/VIS IWC-5000 A IWC-1220(a) 8 8* 8 0.148 HY/VIS IWC-5000 3 IWC-1220(a) 8*8-8 0.148 HY/VIS IWC-5000 8"-HCB-ll 33B-HCB-11-1 150 150 2 IWC-1220 (a) S.S. 8 0.148 HY/VIS IWC-5000 A IWC-1220 (a), (d) S.S. 3/4 HY/VIS IWC-5000 338-HCB-ll H-1 IWC-1220(a) HY/VIS IWC-5000 B IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 C IWC-1220(a) S.S. 0 0.148 HY/VIS IWC-5000 8"-GDB-10 33B-GCB-10-21 450 350 33B-GCB-10 H-36 NON-EXEMPT C-E-l&2 338-GCB-10 H-37 NON-FXEMPT C-E-l&2 338-GCB-10 H-38 NON-EXEMPT "-E-l&2 33B-GCB-lO-21B 450 350 33B-GCB-10 H-39 NON-EXEMPT C-E-2 8"-GCB-10 338-GCB-10-20B 450 350 33B-GCB-10 H-41 NON-EXEMPT C-E-2 33B-GCB-10-21A 450 350 33B-GCB-lO H-42 NON-EXEMPT C-E-2 10"-GCB-10 33B-GCB-10-12 450 350 51H IWC-1220(d) S.S. 1 HY/VIS INC-5000 51J IWC-1220(d) S.S. 1 HY/VIS IWC-5000 E IWC-1220(d) S.S. 1. HY/VIS IWC-5000 SID IWC-1220(d) S.S. 1 HY/VIS IWC-5000 51C IWC-1220(d) S.S. 2 HY/VIS IWC-5000 G IWC-1220(d) S.S. 2 HY/VIS IWC-5000

TECO/ DAVIS .SSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE I SYhlEM LOW PRESSURE INJECTION CLASS 2 ISO NO.PM 233F REV.111%ID NO. M-033 REV.25 l'AG E S OF 6 oN CODE ozW Z SECTION METHOD Eh z5$ ALI.OWING PIPl; DATA OF x5W 9$$ EXEMPTION INSPECTION STRESS 9 l 8NE SPOOL PIECE ywg yW6 WELD SUPPORT OR NitC SIZE PHICKN ESS (TABLE DATA j NUMBEft NUM11Elt Q O a. ooh NUMBER NUMBER EXEMPTaON MATERIAL (ia.) (en.) IWC-2t,00) PolNTS REMARKS g 10"-GCB-10 33B-GCB-10-13 450 350 33B-GCB-1 H-2 NON-EXEMPT CaE-l&2 (continued) 33B-CCB-10 H-1 NON-EXEMPT C-E-2 C IWC-1220(d) S.S. 1 HY/VIS IWC-5000 D

  • IWC-1220(d)

S.S. 1 HY/VIS IWC-5000 338-GCB-10-14 450 350 33B-CCB-10 H-40 NON-EXEMPT C-E-l&2 2 "-GCB-10 33B-GCB-10-14 450 350 B IWC-1220 (d) S.'S. 2h' O.203 HY/VIS ~ IWC-5000 53 IWC-1220 (d) S.S. 2 G.203 HY/VIS IWC-5000 10"-GCB-10 338-GCB-10-15 450 350 ANO10R 860 NON-EXEMPT C-E-1&2 A IWC-1220 (d) S.S. 4 HY/VIS IWC-5000 33B-GCB-10-16 450 350 33B-GCB-10 H-3 NON-EXEMPT C-E-2 33B-rCB-10-17 450 350 ANCHOR 861 NON-EXEMPT C-E-1&2 o 33B-GCB-10-18 450 350 33C-GCB-10 H-25 NON-EXEMPT C-E-2 33C-GCB-lO H-24 NON-EXEMPT C-E-2 33C-GCB-10 H-23 NON-EXEMPT C-E-1&2 E IWC-1220(d) S.S. 3/4 HY/VIS IWC-5000 57A IWC-1220(d) 'S.S. 1 Hi/VIS IWC-5000 33C-GCB-10 H-22 NON-EXEMPT C-E-2 33C-GCB-10 H-21 NON-EXEMPT C-E-2 338-GCB-10-19 450 350 .33C-GCB-10 H-20 NON-EXEMPT C-E-2 8"-GCB-10 33B-GCB-10-19 450 350 33C-G('B-10 H-19 HON-EXEMPT C-E-2 l 33C-GLB-10 H-34 NON-EXEMPT C-E-1&2 G IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 10*-CCB-6 33B-GCB-6-11 2500 350 60 NON-EXEMPT S.S. 10 1.000 C-G A IWC-1220(d) S.S. 1 HY/VIS IWC-5000 l 33B-CCB-6 H-1 NON-EXEMPT C-E-2 B NON-EXEMPT .S.S. 10 1.000 C-G C NON-EXEMPT .S.S. 10 1.000 C-G 33B-CCB-6 H-13 NON-EXEMPT C-E-1&2 D HON-EXEMPT S.S. 10 1.000 C-G E MON-EXEMPT S.S. 10 1.000 C-G .i L NON-EXEMPT S*S. 10 1.000 C-G 1 I

TECO/DAVIL ESSE / UNIT 1 WEI.D

SUMMARY

SilEl P - TAllLE 1 J SYSIMI LOW PRESSURE INJECTION CLASS 2 ISO NO. PM 233F REV.llP&lD No. M-033 REV.25 Pact; 6 OF 6 o o CODE zw 2 SECTION MET 1100 9y$ I E ALI.OWING PIPE DATA OF 2 9z$ EXEMPTION INSPECTION STRESS 1.IN E SPOct. PIECE $WW WELD SUPPORT OR NRC SIZErit!CKN ESS (TABLE DATA NUMht;R NUMBk.R Qok aOh NUMBER NUMBER EXEMPTION MATERIAL lia.) (in ) IWC-2600) POINTS REMARKS 1;"-CCB-1 338 GCB-1-12 450 350 J IWC-1220(d) S.S. 2 HY/VIS IWC-5000 338-CCB-1 H-1 NON-EXEMPT C-E-2 338-GCB-1 H-36 NON-EXEMPT C-E-l&2 338-GCB-1-ll ANOtOR 859 NON-EXEMPT C-E-l&2 450 350 D IWC-1220(d) S.S. 3/4 HY/VIS IWC-5000 33B-GCB-1 H-16 NON-EXEMPT C-E-2 338-GCB-1-10 450 350 33B-GCB-1 H-15 NON-EXEMPT C-E-l&2 33B-GCB-1 H-37 NON-EXEMPT C-E-2 33B-GCB-1-9 450 350 ~ "~ "O ~ ~ ~ ~ ~~' ~ 33B-GCB-1 H-13 NCH-EXEMPT C-E-l&2 338-GCB-1 H-12 NON-EXEMPT C-E-2 33B-GCB-1-8 450 350 33B-GCB-1 H-ll HON-EXEMPT C-E-l&2 31B-GCB-1 H-10 NON-EXEMPT C-E-2 i 338-GCB-1 H-9 NON-EXEMPT C-E-l&2 33B-GCB-1 H-8 NON-EXEMPT C-E-l&2 33B-CCB-1 H-6 NON-EXEMPT C-E-2 33B-GCE-1 H-5 NON-EXEMPT C-E-2 33B-GCB-1 H-7 NON-EXEMPT C-E-l&2 33B-GCB-1-7 450 350 33B-GCB-1 H-4 NON-EXEMPT C-E-2 B IWC-1220(d) S.S. 2 HY/VIS IWC-5000 33B-GCB-1 H-3 NON-EXEMPT, C-E-2 4"-GCB-2 33B-GCB-1-7 450 350. ALL ALL IWC-1220 (d) S.S. 4 0.120 HY/VIS IWC-5000 33B-GCB-2-5 450 350 ALL ALL IWC-1220(d'. S.S. 4 0.120 HY/VIS IWC-5000 I i e i 1

TECO/ DAVIS-Bt.SSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 CYSTEM LOW PRESSURE INJECTION CLASS 2 ISO NO. PM 233F REV.ll P&lD NO. M-033 REV.25 PAGE 1 OF 20 i PIPE DATA TlilCK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (im.) (in.) POINTS SYSTEM FUNCTION X Y Z 10"-GCB-1 338-GCB-1-1 A S.S. 10 0.250 From Decay Heat Pump C-G EX 0 SURFACE To Decay Heat Removal cooler Including Bypass 10 s.S. 10 0.250 C-G EX 8 SURFACE 11 S.S. 10 0.250 C-G EX 0 SURFACE 12 3,3, 10 0.250 C-G EX 8 SURFACE 33B-GCD-1-2 A S.S. 10 0.250 C-G EX 8 SURFACE 12A g,3, 10 0.250 C-G EX 8 . SURFACE 13 g,3, 10 0.250 C-G EX 8 SURFACE 33B-GCB-1-3 A S.S. 10 0.250 C-G EX 8 SURFACE B 10 0.250 C-G EX 8 SURFACE S.S. l C s,s, 10 0.250 C-G EX 8 SURFACE

TECO/ DAVIS dSSE/ UNIT 1 WELD

SUMMARY

SiiEET - TABLE 2 SYSTEM LOW PRESSURE INJECTION CLASS 2 ISO NO. PM 233F REV.11 P&lD NO. M-033 REV.25 PAGE 2 OF 20 FIPE DATA TillCK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER HUMBER SUPPOPT NUMBER MATERIAL (ta.) (in.) POINTS SYSTEM FUNCTION X Y Z 10"-GCB-1 33B-GCB-1-3A 14 S.S. 10 0.250 From Decay Heat Pump C-G EX 8 SURFACE (continued) To Decay Heat Removal Cooler Including Bypass A g,3, 10 0.250 C-G EX 8 SURFACE B S.S. 10 0.250 C-G EX 8 SURFACE C S.S. 10 0.250 C-G EX 8 SURFACE D S.S. 10 0.250 C-G EX 8 SURFACE E 3,s. 10 0.250 C-G EX 8 SURFACE F s.S. 10 0.250 C-G EX 8 SURFACE H 10 0.250 C-G EX 8 SURFACE 3,3, I 10 0.250 C-G EX 8 SURFACE g,3, r J 10 0.250 C-G EX 8 SURFACE S.S. 14A 10 0.250 C-G EX 8 Supr.*.at g,g, I

TECO/ DAVIS-or:SSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2

YSTEM IDW PRESSURE INJECTION CLASS 2 ISO NO.

PM 233F REv.11 P&ID NO. M-033 REV.25 PAGE 3 OF 20 FIPE DATA TillCK-STRESS IJNE SPOOL PIEEE WELD SIZE NESS DATA FUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (am.) (la.) POINTS SYSTEM FUNCTION X Y Z 10"-GCB-1 3 3B -GC3-1-4 A S.S. 10 0.250 From Decay Heat Pump C-G EX 8 SURFACE (continued) To Decay Heat Removal Cooler Including Bypass 8 3,s, 10 0.250 C-G EX 8 SURFACE &"-GCB-10 338-GCB-1-4 15 6 0.134 Decay Heat Removal C-G EX 8 SURFACE 3,3, Cooler To Isolation valve 10"-GC3-1 338-GC3-1-4 C 10 0.250 From Decay nicat Pump C-G EX 8 SURFACE { 3,3, To Decay Heat Removal Cooler Including Bypass D s,s, 10 0.250 C-G EX 8 SURFACE E S.S. 10 0.250 C-G EX 8 SURFACE G S.S. 10 0.250 C-G EX 8 SURFACE I 6*-GCB-10 338-GCB-1-5 ISA S.S. 6 0.134 Decay Heat Removal C-G EX 8 SURFACE Cooler tb Isolation valve ) 33B-GCB-1-6 16 S.S. 6 0.134 C-C EX 8 SURFACE 1 D S.S. 6 0.134 C-G EX 8 SURFACE 1 l I 1

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SHEET - TABLE 2 SYSTEM LOW PRESSURE INJECTION CLASS 2 ISO NO. PM 233F REV.11 P&ID NO. M-033 REV.25 FACE 4 OF 20 PIPE DATA 11 tick-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (ie.) (en.) POINTS SYSTEM FUNCTION X Y Z 0*-GCB-10 338-GCB-1-6 C S.S. 6 0.134 Decay Heat Removal C-G EX 8 SU RACE (continued) (continued) Cooler To Isolation valve B S.S. 6 0.134 C-G EX 8 SURFACE 1 A S*S* 6 0.134 C-G EX 8 SURFACE 17 S.S. 6 0.134 C-G EK 8 SURACE 10"-GCB-10 33B-GCB-10-1 A S.S-10 0.250 C-G EX 8 SURFACE 20D S S-10 0.250 C-G EX 8 SURFACE 20C S.S. 10 0.250 C-G EX 8 SURFACE C S.S. 10 0.250 C-G EX 8 SURFACE D S.S. 10 0.250 C-G EX 8 SUNACE 20 S.S. 10 0.250 t C-G EX 8 SUNACE 19 S.S. 10 0.250 C-G EK 8 SURFACE m

TECO/ DAVIS 4SSE/ UNIT 1 WELD

SUMMARY

SHEET - TABLE 2 SYSTEM LOW PRESSURE INJECTION CLASS 2 ISO NO. PM 233F' REv.11 P&ID NO. M-033 REV.25 FAGE 5 OF 20 PRE DATA I THICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATEhiAL (aa.) (in. ) POINTS SYSTEM FUNCTION X Y E 10*-CCB-10 33B-GCB-10-1 A S.S. 10 0.250 Decay Hec 4 Removal C-G EX 8 SURFACE (continued) (continued) Cooler to inclation valve 6*. 6 -10 338-GCB-10-1. 18 S.S. 6 0.134 C-G EX 8 SURFACE 10"-CCB-10 33B-GCB-10-1 B g,g, 10 0.250 C-G EX 8 SURACE D S.S. 10 0.250 C-G EX 8 SURFACE 21 10 0.250 C-G EX 8 SURFACE S.S. 33B-GCB-10-3 21A S.S. 10 0.250 C-G EX 8 SURFACE i 351 S.S. 10 0.250 C-G EX 8 SURFACE 218-1 S.S. 10 0.250 C-G EX 8 SURFACE 21C S.S. 10 0.250 CM EX 8 SURFACE 338-GCB-10-4 22 g,s, 10 0.250 C-G EX 8 SURFACE 22A 10 0.250 M n8 SUWE 3,3,

l 0 2 F E E E E E E E E E E O Z C C C C C C C C C C A A A A A A A A A A F F F F F F F F F F R R R R R R R R R R U U U U U U U U U U S S S S S S S S S S 6 E GA 8 8 8 8 8 8 8 8 8 8 F Y X X X X X X X X X X E E E E E E E E E E 5 G G G C G G G 4 G G 1 2 C C C C C C C C C C V ER n l o 3 N ai 3 O vt I 0 T oa C ml M N eo R s U I F tao O M eT E H N T r F yee D Y al v I S col eoa P DCv 1 1 l V E S S R SAT ETN 2 RAI TDO E P S P 1 L 3 T B 3 A I 2 N T KS) 0 0 0 0 0 0 0 0 0 0 U M CS. 5 5 5 5 5 5 5 5 5 5 a / - P IEi 2 2 2 2 2 2 2 2 2 2 HN( E T T 0 0 0 0 0 0 O 0 0 0 S E S. E O. H N A S T E )a. 0 0 0 0 0 0 0 0 0 0 O A S Y S D IZi 1 1 1 1 1 1 1 1 1 1 ( I R I S V A E A P DM nP L / M IR S. S. S. S. S. S. S. S. S. S, A OU 2 C S E E T S S S S S S S S S S TD S A L S M E A W LC REB MUN TR O PP U S R DE LB B C N EM 2 3 4 O WU D C B 2 2 A C D 2 F I N TCEJ 4 5 N ) E I 0d 0 CER 1 e 1 R IE - u E PB Bn B Ci C U LM Gt G S OU - n S ON 8o 8 E P 3 c 3 S 3( 3 R P M 0)d 1 e R - u EE Bn B Ci d N n JM Gt E IU - n T N o 0 S 1 (c YS

TECO/ DAVIS-J SE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM LOW PP. ESSURE INJECTION CLASS 2 ISO NO. PM 233P REV.11 P&ID NO. M-033 REV.25 PAGE 7 OF 20 PEPE DATA THICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (n.) (ie. ) POINTS SYSTEM FUNCrlON X Y Z 10"-GCB-10 33B-GCB-10-6 A S.S. 10 0.250 Decay Heat Removal C-G EX 8 SURFACE (continued) Cooler to Isolation Valve 24D S.S. 10 0.250 C-G EX 8 SURFACE B S.S. 10 0.250 C-G EX 8 SURFACE C S.S. 10 0.250 C-G EX 8 SURFACE D 10 0.250 C-G EX 8 SURFACE E"-GCB-10 338-GCB-10-6 G S S-8 0.250 C-G EX 8 SURrACE 10"-GCB-10 338-GCB-10-6 E 10 0.250 C-G EX 8 SURFACE g,g, l l P S.S. 10 0.250 C-G EX 8 SURFACE 31 10 0.250 C-G EX 8 SURFACE 3,3, 33B-GCB-10-8 A S.S. 10 0.250 C-C EX 8 SURFACE l \\ i j

s TECO/ DAVIS otSSE/ UNIT 1 WELD

SUMMARY

SilEET. - TABLE 2 SYSTEM IDW PRESSURE INJECTION CLASS 2 ISO NO. PM 233P REV.11 P&ID NO. M-033 REV.25 PAGE 8 OF 20 PIPE DATA TlilCK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIA!. (ie.) (a. ) POINTS SYSTEM FUNCTION X Y Z 10*-GCB-10 338-GCB-10-8 B S.S. 10 0.250 Decay lieat Removal C-G EX 8 SURFACE (continued) (continued) Cooler To Isolation valve 32 S.S. 10 0.250 C-G EX 8 SURFACE 33B-GCB-10-9 A S.S. 10 0.250 C-G F2 8 SURFACE B S.S. 10 0.250 C-G EX 8 SURFACE C S.S. 10 0.250 C-G EX 8 SURFACE D 10 0.250 C-G EX 8 SURFACE 3,3, E 10 0.250 C-G EX 0 SURFACE 3,3, F S.S. 10 0.250 C-C EX t SURFACE 33 S.S. 10 0.250 C-G EX t SURFACE 33B-GCB-10-10 A S 8-10 0.250 C-G EX E SURFACE e

0 2 F O E E E E E E E E E E E Z C C C C C C C C C C C A A A A A A A A A A A F F F F F F F F F F F R R R R R R R R R R R U U U U U U U U U U U S S E S S S S S S S S 9 E G A P 8 8 8 8 8 8 8 8 8 8 8 Y X X X X X X X X X X X E E E E E E E E E E E X G G G G G G G G G G G 5 2 C C C C C C C C C C C VER n 3 N t o ai O 3 I vt 0 T oa C ml M N eo U R s F I t O. M ao eT E H N T r b yee D Y al v l S col a eoa P DCV 1 1 S S v SAT 2 E ETN R RAI TDO EL P S P 1 3 B T A 3 I 2 0 0 0 0 0 0 0 0 0 0 0 N T KS) U M CS n 5 5 5 5 5 5 5 5 5 5 5 l 2 2 2 2 2 2 2 2 2 2 2 / - P leu iN( E T 0 0 0 0 0 0 0 0 0 0 0 ST E Sl O E di N A S T E )n. 0 0 0 0 0 0 0 0 8 8 O A 1 1 1 1 1 1 1 1 8 Zi SY S D I ( I R I S V A E A P DN I L F / c A Ob 2 I R S. S S. S. S. S. S. S. S. S. 3, CS E E T S S S S S S S S S S S TD S A L S M E A W LC R EB MU N TR O PPU S R DE LB A N EM 4 5 9 9 o O WU B C 3 A B C E 3 2 A 2 I N T CE J 0 1 1 1 7 N E -) C 0d 0 0 I ER 1 e 1 1 R B nu E IE P n B B ui C C U LM S OU Gt G G n S ON 8o B B P 3 c 3 3 E S R 3( 3 3 P WOL 0)d 0 R 1e 1 u EE Bn N Ci B B M IW Gt C E LU n G T N " o S 1 (c "8 0 YS

TECO/ DAVIS-o SSE/ UNIT 1 WELD SUhStARY Sl!EET - TABLE 2 SYSTEM LOW PRESSURE INJECTION CLASS 2 ISO NO. PM 2 3." REV.11 P&lD NO. M-033 REV.25 PAGE 10 OF 20 FIPE DATA THICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (ie.) (a) POINTS SYSTEM FUNCTION X Y Z 8"-GCB-10 33B4CB-10-7 8 S.S. 8 0.250 Decay Heat Removal C-G EX 8 SURFACE (continued) (continued) Cooler To Isolation valve C S.S. 8 0.250 C-G EX 8 SURFACE D S.S. 8 0.250 C-G EX 8 SURFACE 30 S.S. 8 0.250 C-G EX 8 SURFACE 33B-GCB-10-20 62 8 0.250 C-G EX 8 SURFACE g,S, 63A 8 0.250 C -G EX 8 SURFACE g,g, A S.S. 8 0.250 C-G EX 8 SURFACE B S.S. 8 0.250 C-G EX 8 SURFACE C S,S, 8 0.250 C-G EX 8 SURFACE 338-GCB-10-20A 63 S.S. 8 0.250 C-G EX 8 SURFACE A S.S. 8 0.250 C-G EX 8 SURFACE

0 2 F O E E E E G E E E E E E Z C C C C C C C C C C A A A A A A A A A A A F F F F F F F F F F F R R R R R R R R R R R U U U U U U U U U U U S S S S S S S S S S 1 1 E GA F 8 8 8 8 8 8 8 8 8 8 8 Y X X X X X X X X X X X E E E E E E E E E E E 5 1 G G G G G G G G G G G 2 C C C C C C C C C C C V ER n N l o 3 3 I ai O vt 0 T oa C ml N eo M U R s F I t O. M ao E eT N T H S r D Y yee l S al v col eoa F DCV 1 1 V S S E SAT R ETN 2 RAI TDO E S P 1 F L 3 B T 3 A I 2 T KS) 0 0 0 0 0 0 0 0 0 0 0 NU-M CS. 5 5 5 5 5 5 5 5 5 5 5 n I O 2 2 2 2 2 2 2 2 2 2 2 P tE / 1N ET 1 0 0 0 0 0 0 0 0 0 0 0 SE SE O EI BI N A S T E ). O A Zm S D I m 8 8 8 8 3 8 8 8 8 8 8 SY I S ( IR VA E ADM E P L /M 2 A OU IR CS E S. S. S. 3, 3, 3, S, S. S. S. S. E T TD S A S S S 3 3 g S S S S S L S M E A W LC R EB MUN TR O PPU S R DE LB N EM 0 4 5 3 4 O WU B 7 6 6 A B 7 F 7 E C N I T CE A J 0 1 2 2 N E -) I C Od O ER le l E IE u P R B Bn B U LM Ci C S OU Ct G S OH n P 8o 8 E S 3c 3 R 3( 3 P W ) ) U d R Oe l u E E - n B N Bi M IM Ct E LU Gn T N - o S 8" c Y ( S

TECO/ DAVIS. SSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM LOW PRESSURE INJECTION CLASS 2 ISO NO. PM 233P REV.11 P&lD NO. M-033 REV.25 PAGE 12 OF 20 PIPE DATA TillCK. STRESS IJNE SPCOL PILCE WELD SIZE NESS DATA NUMBER HUMBER NUMBER SUPPORT NUMBER MATERIAL (an.) (ia.) POINTS SY!rrEM FUNCTION X Y Z &*-GCB-lO 338-TB-lO-21 DCP S.S. 8 0.250 Decay Heat Removal C-G EY 8 SURFACE (continued) (continued) Cooler To Isolation valve 66 S.S. 8 0.250 C-G EX 8 SURFACE 33B-CCB-10-21B 68 S.S. 8 0.250 C-G EX 8 SURFACE 77 S.S. 8 0.250 C-G EX 8 SURFACE A S S. 8 0.250 C-G EX 8 SURFACE 69 8 0.250 C-G EX 8 SURFACE g,3, 338-GCB-lO-22 A S.S. 8 0.250 C-G EX 8 SURFACE B S.S. 8 0.250 C-G EX 0 SURFACE 67 S.S. 8 0.250 C-G EX 8 SURFACE 338-CCB-10-208 71 S.S. 8 0.250 C-G EX 8 SURFACE l

b 3 TECO/ DAVIS-SSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 F&lD NO. M-033 REV.25 FAGE 13 OF 20 CYfrrEM LOW PRESSURE INJECTION C1. ASS 2 ISO NO. PM 233F ggy.11 PIPE DATA THICK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (a) ' (ia.) POINTS 8YSTEM FUNCTION X Y 2. &"-GCB 338-GCB-10-20B 71CP S.S. 8 0.250 Decay Heat Removal C-G EX 8 . SURFACE (continued) (continued) Cooler To Isolation Valve B S.S. 8 0.250 C-G EX 8 SURFACE A S.S. 8 0.250 C-G EX 8 SURFACE 72 S.S. 8 0.250 C-G EX 8 SURFACE 3 38-GC3-10-21A 76 S.S. 8 0.250 C-G EK 8 SURFACE A S.S. 8 0.250 C-G EX B SURFACE 75 S.S. 8 0.250 C-G Ex 8 SURFACE t 10"-GCB-10 338-GCB-10-12 A S.S. 10 0.250 C-G Ex 8 SURFACE 51G S.S. 10 0.250 C-G EX 8 SURFACE 51F 10 0.250 C-G EX 8 SURFACE 3,3, SIB S.S. 10 0.250 C-G EX 8 SUltFACE I

TECO/ DAVIS SSE/ UNIT 1 WELD

SUMMARY

SiiEET - TABLE 2 CYSTEM LOW PRESSURE INJECTION CLASS 2 ISO NO. PM 233F REV.11 PalD No. M-033 REV.25 PAGE 14 OF 20 FIPE DATA THICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBEli SUPPORT NUMBER MATERIAL (an.) (ie.) POINTS SYSTEM FUNCTION X Y Z 10"-GCB-10 33B-GCB-10-12 51A s,s, 10 0.250 Decay Heat Rearwal C-G EX 8 SURFACE (continued) (con tinued) Cooler To Isolation Valve 51 S.S. 10 0.250 C-G EX 8 SURFACE 338-GCB-10-13 50 S.S. 10 0.250 C-G EX 8 SURFACE A S.S. 10 0.250 C-G EX 8 SURFACE E S,s, 10 0.250 C-G EX 8 SURFACE F s,s, 10 0.250 C-G EX 8 SURFACE 6"-CCB-10 33B-GCB-10-13 G S.S. 6 0.134 C-G EX 8 SURFACE J 0.134 C-G EX 8 SURFACE S.S. 49 S.S. 6 0.134 C-G EX 8 SURFACE 10"-GCB-10 338-GCB-10-33 B S.S. 10 0.250 C-G EX 8 SURFACE

TECO/ DAVIS JSE/ UNIT 1 WELD

SUMMARY

Sl!EET - TABIE 2 SYSTEM LOW PRESSURE INJECTION CLASS 2 ISO NO. PM 233F REV.11 PalD NO. M-033 REV.25 PAGE 1; 0F 20 PIPE DATA THK'K. STRESS LINE SPOOL PIECE WELD S11.E NESS DATA NUMBER HUMBER NUMBER SUPPORT NUMBER MA1ERIAL (a) (in.) FOINTS SYSTEM FLNCTWN X Y X 10"-GCB-10 338-GCB-10-13 H S.S. 10 0.250 Decay Heat Removal C-G EX 8 SURFACE (continued) (continued) Cooler To Isolation Valve 5. S.S. 10 0.250 C-G EX 8 SURFACE 33B-GCB-10-14 C S.S. 10 0.250 C-C EX 8 SURFACE A S.S. 10 0.250 C-G EX 8 SURFACE 54 S.S. 10 0.250 C-G EX 8 SURFACE B S.S. 10 0.250 C-G EX 8 SURFACE 33B-GCB-10-16 55 S.S. 10 0.250 C-G EX 8 SURFACE A S.S. 10 0.250 C-C EX 8 SURFACE 56 S.S. 10 0.250 C-G EX 8 SURFACE 33B-GCB-10-17 A S.S. 10 0.250 C-G EX 8 SURFACE 57 S.S. 10 0.250 C-G EX 8 SURFACE

TECO/ DAVIS dSE/ UNIT 1 WELD

SUMMARY

SHEET - TABLE 2 SYMEM IDW PRESSURE INJECTION CLASS 2 ISO NO. PM 233P REV.11 F&ID NO. M-033 REV.25 FACE 16 OF 20 PIPE DATA THICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (en.) (ie.) POINTS SYSTEM FUNCTION X Y Z 10"-GCB-10 33B-GCB-10-18 A S S-10 0.250 Decay Heat Removal C-G EX 8 SURFACE (continued) Cooler To Isolailon valve B 8*8* 10 0.250 'C-C EX 8 SURFACE C 10 0.250 C-G EX 8 SURFACE D S.S. 10 0.250 C-G EX 8 SURFACE G S.S. 10 0.250 C-G EX 8 SURFACE 338-GCB-10 A , 10 0.250 C-G EX 8 SURFACE 3,3, B S.S 10 0.250 C-G EX 8 SURFACE G"-GCB-10 33B-GCB-10-19 58 S.S. 8 0.250 C-G EX 8 SURFACE C S.S. 10 0.250 C-G EX 8 SURFACE D S.S. 10 0.250 C-G EX 8 SURFACE E S.S. 10 0.250 C-G EX 8 SURFACE I

TECO/ DAVIS ofSSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 2 CygrEM LOW PRESSURF INJECTION CLASS 2 ISO NO. PM 233F REV.11 P&lD NO. M-033 REV.25 PAGE 17 OF 20 PIPE DATA TlilCK-STRESS LIN F. SPOOL PIECE WELD SIZE NESS DATA NUMPIR NUMBER NUMBER SUPPORT Ntf.8ER MATERIAL (ie.) (in.) POINTS SYSTEM FUNCTION X Y E 8"-GCB-10 338-GC9-10-19 F S.S. 10 0.250 Decay Heat Removal C-G EX 8 SURFACE (continued) (continued) Cooler To Isolation Valve H S S-10 O.250 C-G EX 8 SURFACE 59 S.S. 10 0.250 C-G EX 8 SURFACE 10"-GCB-1 338-GCB-1-12 47A S.S. 10 0.250 Frcan Decay Heat Pump C-G EX 8 SURFACE To Decay Heat Removal Cooler including Bypass H S.S. 10 0.250 C-G EX 8 SURFACE G S.S. 10 0.250 C-G EX 8 SURFACE F S.S. 10 0.250 C-G EX 8 SURFACE D S.S. 10 0.250 C-G EX 8 SURFACE B S S. 10 0.250 C-G EX 8 SURFACE 6*-GCB-10 33D-GCB-1-12 C 8 8. f 0.134 Decay Heat Removal C-G EX 8 SURFACE Cooler To Isolation Valve 48 S.S, 6 0.134 C-G EX 8 SURFACE I

l l 0 2 P s O E E E E E E E E E E Z C C C C C C C C C C A A A A A A A A A A F F F F F F F F F F R R R R R R R R R R 8 U U U U U J U U U U 1 S S S S S S S S S S E GAP 8 8 8 8 8 8 8 8 8 8 Y X X I X X X X x I X E E E E E E E E E E X C G G G G G G G. G G 5 C C C C C C C C C C 2 VE M R N P 3 OI s 3 T t s 0 C a ra N et ep M U H al y F eoB yHo O. M t Cg cy n E aali N T Dcad S evu D Y mDol I S o mc roen P FTRI 1 1 S S V SAT 2 E. ETN RAI F TDO 1 E F S P L 3 T B 3 A 2 INT KS) 0 0 0 0 0 0 0 0 0 0 U M l m CS. 5 5 5 5 5 5 5 5 5 5 / - P iEU 2 2 2 2 2 2 2 2 2 2 E DN T 0 0 0 0 0 0 0 0 0 0 S E S E 0 4

rH N

A b S T E ). 0 0 0 0 0 0 0 0 0 0 SY O A ZmD 1 1 1 1 1 1 1 1 1 1 S D I I R I S VA A EP DM IP L /M 2 A OU I CS R E E S. S. S. S. s, S. 3, S. S. S. T TD S A S S S S s S s S S S L S M E A W L C R E B MU N TR O P PU S I R DE N LB O EM 7 I WU 4 A B C B A T N C E J 1 N 1 I 2 0 E 1 1 1 E C ER 1 1 R IE B U P B B C B S LM C G C G G S OU B E ON 8 B 3 R P 3 3 P S 3 3 3 WOL 1 1 R EE B B B C C N M G G M I E LU T N 0 0 S 1 1 Y S

_.m. TECO/ DAVIS-ndSSE/ UNIT 1 WELD

SUMMARY

SilEET - TABI.E 2 SYSTEM IDW PRESSURE INJECTION CLASS 2 ISO NO. PM 233P REv.11 P&ID NO. M-033 REV. ":5 FAGE. 19 OF 20 FIPE DATA 11EICK. drI1tESS LINE SPOOL PIECE WELD SIZE NESS DAT/. NUMBER HUMBER NUMBER SUPPORT NUMBER MA1 TRIAL (im.) (im.) POIN15 SYSTEM FUNCTION K Y Z 10"-CCB-1 335-2 9 45 S.S. 10 0.250 From Decay Heat Pump C-G EX 8 SURFACE (continued) 'Ib Decay Heat Removal Cooler Incismiing Bypass 44A S.S. 10 0.250 C-G EX 8 SURFACE 44 S.S. 10 0.250 C-G EX 8 SURFACE D S*S. 10 0.250 C-G EX 8 SURFACE C S.S. 10 0.250 C-G EX 8 SURFACS l B S.S. 10 0.250 C-G EX 8 SURFACE A S.S. 10 0.250 C-G EX 8 SUkFACE 43 3,3, 10 0.250 C-G EX 8 SURFACE 42 88* 10 O.250 C-G EX 8 SURFACE. 33B-GCB-1-7 41 S.S. 10 0.250 C-G EX 8 SURFACE f

l l 1 l1 0 2 F O E E Z C C A A F F R R 0 U U S S 2 E GA F 8 8 Y X X E E 5 1 4 G 4 2 C C VER pm 3 N u P 3 O s I 0 T t s C a ra M N et ep U Hal y F eoB yHo a cg O M cy n E eali N T Dcad S evu D Y nDol l S eo mc roen P FTRI 1 1 V S 3 E SA1 R ETN 2 RAI F TDO E 3 S P 1 L 3 B T 2 A IN T M KS) 0 0 U P C S n. 5 5 / - IN( IIEi 2 2 E T T 0 0 S E S E O H N 4 . S 9 A E )n. 0 0 T S Y Ze t S ( 1 1 h D I IV R, E a A P 7, M I L P f M A O U 2 I C S R E S. E T T D S A S L S M E A W LC R EB MUN TR O PPU S R DE LB e N EM O WU C A I N TCE JN E 7) I C - d ER 1 e E IE - u P R B Bn U LM Ci C t S OU - n S ON Do E P 3 S 3 (c R P W O ) L d R 1e EE u mn B N M I M ait E LU - n T N o 0 S 1 (c YS t

TECO/ DAVIS. JSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 1 SYS1.Ekt REFUELING CANAL AND IN CORE TANK FILL & DRAIN CLASS 2 . ISO NO. PM 2 3 3G, REV. lP&ID NO. M-0 3 3, REV. 25 PAGE 1 OF 1 o f. o CODE Ey Er sECTION METHOD l h 2D z ALLOWING ~ PIPE DATA OF 9$" 9h' EXEMPTION INSPECTION STRESS r4 U LINE SPOOL PIECE CCh" y $if yg WELD SUPPORT OR NRC SIZE THICKNESS (TABLE DATA NUMBER NUMBER Q NUMBER NUMBER EXEMPTION M ATERIAL (m) (m) I F -2600) POINTS REMARKS 8"-HCB-11 33B-HCB-11-1 150 150 alt. ALL IWC-1220(a) S.S. 8 0.148 MY/VIS IWC-5000 338-HCB-11-2 150 150 21 IWC-1220(a) S.S. 8 0.148 BY/VIS IWC-5000 8"-IICC-94 33B-HCC-94-1 20 150 ANCllOR 869 IWC-1220(a) HY/VIS IWC-5000 1 I i 8

TECO/ DAVIS-L_,SE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 M~ C,YSTEM LOW PRESSURE INJECTION - CORE FIDODING C1. ASS 2 . ISO NO.PM 2 3 4 A, REV. 4 P&lp NO. PAGE 1 OF 3 o o CODA' W z SEC110d METHOD $ zh E ALLOWING PIPE DATA OP 2 y 2 EXEMPTIOt t INSPECTION STRESS 9 LINE SPOO!. PIECE Aof a$gh yWW WELD SUPPORT OR NRC SIZE THICKNESh (TABLE DATA NUMBER NUMBER O NUMBER NUMBER EXEMPTION MATERIAL On.) (in.) IWC-2600) POINTS REMARKS 14*-FCB-2 33B-PCB-2-1 700 300 23 NON-EXEMPT S.S. 14 0.375 C-G A NON-EXEMPT S.S. 14 0.375 C-G B NON-EXEMPT S.S. 14 0.375 C-G C NON-EXEMPT S.S. 14 0.375 C-G D NON-EXEMPT S.S. 14 0.375 C-G E NON-EXEMPT S.S. 14 0.375 C-G El IWC-1220(d) S.S. 1 HY/VIS IWC-5000 33B-FCB-2-1A 700 300 32 NON-EXEMPT S.S. 14 0.375 C-G 3. NON-EXEMPT S.S. 14 0.375 C-C 24 NON-EXEMPT S.S. 14 0.375 C-G 14"-CCB-5 338-CCB-5-1 2500 300 25 NON-EXEMPT S.S. 14 1.250 c-G 338-CCB-5 H-6 NON-EXEMPT C-E -2 C IWC-1220(d) S.O-3/4 HY/VIS IWC-5000 33B-CCD-5 H-4 NON-EXEMPT = C-E-2 B NON-EXEMPT S.S. 14 1.250 C-G A NON-EXEMPT S.S. 14 1.250 C-G 33B-C01-5 15-3 NON-EXEMPT C-E-2 10"-CCB-6 33B-CCB-6-1 2500 350 1 NON-EXEMPT S.S. 10 1.00 C-G 1A NON-EXEMPT S.S. 10 1.00 C-G IB NON-EXEMPT S.S. 10 1.00 C-G A NON-EXEMPT S.S. 10 1.00 C-G 33B-CCB-6-2 2500 350 2 .NON-ELEMPT S.S. 10 1.00 C-G A NON-EXEMPT S.S. 10 1.00 C-G B NON-EXEMPT S.S. 10 1.00 C-G C NON-EXEMPT S.S. 10 1.00 C-G 33B-CCB-6 H-11 NON-EXEMPT C-E-1 & 2 33B-CCB-6-3B 2500 350 3 NON-EXEMPT S.S. le 1.00 C-G 338-CCB-6 H-10 NON-EXEMPT C-E-1 & 2 338-CCB-6 H-9 NON-EXEMPT C-E-1 & 2 3A NON-EXEMPT S.S. 10 1.00 C-C

TECO/ DAVIS ESSE / UNIT 1 M1D

SUMMARY

SilEET - TABLE 1 f.YSTEM IhW PRESSCRE INJECTION - CORE FIDODING CIASS 2 . ISO NO.PM 234 A REV.4 P&lD NO. M-034, REV. 17 FAGE 2 OF 3 oh CODE o$zg M SECTION METHOD ALLOWING PIFE DATA OF z9

  • g g h.

2 EXEMPTION INSPECTION STRESS LINE SPOOL PIECE y WELD SUPPORT OR NRC SIZE TitlCKNESS (TABLE DATA NUMBER NUMBER con O NUMBER NUMBER EXEMPTION MATERIAL (m.) (ie.) IWC-2600) POINTS REMARKS 10"-CCB-6 338-CCB-6-3A 2500 350 33-CCB-6 H-8 NON-EXEMPT C-E-2 (continued) 33-CCB-6 H-7 NON-EXEMPT C-E-1 & 2 338-CCB-6-4 2500 350 4 Not-EXEMPT S.S. 10 1.00 C-G A -..-EXEMPT S.S. 10 1.00 C-G 33B-CCB-6 H-6 NON-EXEMPT C-E-2 Al NON-EXEMPT .S.S. 10 1.00 C-G 33B-CCb-6-5 2500 350 5 NON-EXEMPT S.S. 10 1.00 C-G A NON-EXEMPT S.S. 10 1.00 C-G 33B-CCB-6-6 2500 350 6 NON-EXEMPT S.S. 10 1.00 C-G A NON-EXEMPT S.S. 10 1.00 C-G 33B-CCB-6 H-5 NON-EXEMPT C-E-2 Al IWC-1220(dl S.S. 3/4 HY/VIS IWC-5000 14"-FCB-2 338-FCB-2-2 700 300 9 NON-EXEMPT S.S. 14 0.375 C-G 33B-FCB-2 H-1 NON-EXEMPT C-E-2 33B-PCB-2-2A 700 300 31 NON-EXEMPT 5.S. 14 0.375 C-G A NON-EXEMPT S.S. 14 0.375 C-G B NON-EXEMPT S.S. 14 0.375 C-G C IWC-1220(d) S.S. 1 HY/VIS INC-5000 10 NON-EXEMPT S.S. 14 0.375 C-G 14"-CCB-5 33B-CCB-5-2 2500 300 11 NON-EXEMPT S.S. 14 1.250 C-G B NON-EXEMPT S.S. 14 1.250 C-G Al IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 338-CCB-5 H-1 NON-EXEMPT C-E-1 & 2 A NON-EXEMPT S.S. 14 1.250 C-G 10"-CCB-6 338-CCB-6-9 2500 350 18 NCN-EXEMPT 3.S. 10 1.00 C-G B NON-EXEMPT S.S. 10 1.00 C-G 18A NON-EXEMPT S.S. 10 1.00 C-G 188 NON-EXDFT S.S. 10 1.00 C-G Al IWC-1220 (d) s.S. 3/4 HY/VIS IwC-5000

e TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilELT - TABLE 1 SYSTEM LOW PRESSURE INJECTION - CORE FLOODING CLASS 2 . ISO NO. PM 23 4 A, REV. 4 PalD NO. M-0 3 4, REV.17 PAGE 3 OF 3 0 o CODE y SECTION MEIllOD I Z D Z ALLOWING PIPE DATA OP $2 $ 0 EXEMPTION INSPEX"IlON STRESS LINE SPOOL PIECE yWW g WELD SUPPORT OR NRC SIZE TIllCKNESh (TABLE DATA NUMBER NUMBER cok o NUMBER NUMBER EXEMPTION MATERIAL (m) (im.) IWC-2600) POINTS REMARKS lO*-CCB-6 338-CCB-6-8 2500 350 19 NON-EXEMPT S.S. 10 1.0 C-G (continued) A NON-EXEMPT S.S. 10 1.0 C-G 338-CCB-6-7 2500 350 20 NON-EXEMPT S.S. 10 1.0 C-G B1 IWC-122O(d) S.S. 3/4 ItY/VIS IWC-5000 33B-CCB-6 H-4 NON-EXEMPT C-E-2 33B-CCS-6 H-3 NON-EXEMPT C-E-1 & 2 B NON-EXEMPT S.S. 10 1.0 C-G A NON-EXIMPT S.S. 10 1.0 C-G

TECO/ DAVIS-BESSE/ UNIT 1 WELD SUMi*ARY SilEET - TABLE 2 SYSTEM LOW PRESSURE INJECTION - CORE FLOODING CLASS 2 ISO NO. PM 2 3 4 A, REV.14 P&lD NO. M-034, REV. 17 FACE 1 OF 1 FIPE DATA TitICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (ie.) (ie.) POINTS SYSTEM FUNCTION X Y Z 10"-CCB-6 338-CCB-6-1 B S.S. 10 1.00 L.P. injection lines C-G EX 1 HY/VIS inside containment 33B-CCB-6-9 A S.S. 10 1.00 (PEN 27 and 28) up to C-G EX 2 SURFACE but not including check valves DH-76 and 77, core flooding lines from each tark up to but not including check valves CF-28 and 29.

TECO/ DAVIS oESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE I EYSTEM CONTAINMENT SPRAY CLASS 2 . ISO NO. PM 2 34B,REV.8 P&lD NO. M-034, REV. 17 FAGE 1 OF 3 0 0 CODE gW SECTION METtlOD zF$ 2 ALLOWING PIPE DATA OF 2$5 9 EXEMPTION INSPM: TION STRESS LINE SPOOL PIECE gwO gW WELD SUPPORT OR NRC SIZE THICKNESS (TABLE DATA NUMBER NUMBER Q8f ob NUMBER NUMBER EXEMPTION MATERIAL (en.) (La.) IWC-2600) POINTS REMARh8 8*-HCB-4 34-HCB-4-10 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYW IS IWC-5000 34-HCB-4-9 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-4-8 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-4-7 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-4-6 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYW IS IWC-5000 34-HCB-4-5 200 300 7 ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-4-4 200 300 ALL ALL IWC-1220 (b) F S. 8 0.148 NYWIS IWC-5000 34-HCB-4-3 200 300 ALL ALL IWC-1220 (b) S S. 8 0.148 HYW IS IWC-5000 34-HCB-4-2 200 300 ALL ALL IWC-1220 (b S.S. 8 0.148 HYWIS IWC-5000 34-HCB-4-1 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 i 34-HCB-8-19 200 300 ALL ALL IWC-1220 (b) S.S* 8 0.148 IIYWIS IWC-5000 34-HCB-4-25 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 NYW IS IWC-5000 34-ilCB-4-24B 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VTS IWC-5000 34-T B-4-24A 200 300 ALL ALL IWC-220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB*4-23 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-IICB-4-22 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS' IWC-5000 34-HCB-4-21 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYW IS IWC-5000 34-HCB-4-20 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-4-19 200 300 ALL ALL IWC-1220 (b) S.S. 0.148 HYW IS n:C-5000 34-HCB-4-18 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYW IS IWC-5000 34-HCB-4-17 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-4-16 2'H) 300 28 IWC-1220 (b) S.SJ 8 0.148 HYWIS IWC-5000 4

TECO/ DAVIS u SSE/ UNIT 1 WELD

SUMMARY

SilEET - TAllLE 1 CYSTEM CONTAINMENT SPRAY C1. ASS 2 . ISO NO. PM 2 34 B,REV.8 PMD NO. M-034, REV.17 PAGE 2 OF 3 o LVDE a 3y SECTION METHOD J Z' D Z ALLOWING PIPE DATA OF 0 $" $ 0 EXEMPTION INSPECTION STRESS LINE SPOOL PIECE 3gw y WELD SUPPORT OR NRC SIZE TitlCKNESd (TABLE DATA NUMBER NUntBER c o a. o NUMBER NUMBER EXEMPTION MATERIAL (m) (m) IWC-2600) POINTS REMARKS 6*-liCB-4 34-HCB-4-15A 200 300 ALL ALL WC-1220 (b) S.S.7 8 0.148 HYWIS IWC-5000 (continued) 34-HCB-4.15 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-4-14 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-4-12 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-4-ll 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.14d HYNIS IWC-5000 31-HCB-8-30 200 300 M.L ALL IWC-1220 (b) S.S. 8 0.148 HYW IS IWC-5000 in"-HCB-8 34-HCB-8-1 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-8-2 200 300 ALL ALL IWC-1220 (b) S.S. G 0.148 HYWIS IWC-5000 34-HCB-8-3 ."00 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 !!YWIS IWC-5000 34-HCB-8-4 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-8-5 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-d-6 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-8-7 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-8-8 200 300 ALL ALL IWC-1220 (b) S.S. 8 o.148 HYWIS IWC-5000 34-HCB-8-9 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYW IS IWC-5000 34-HCB-8-10 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-8-ll 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 tiYWIS IWC-5000 34-HCB-8-12 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-8-13 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 34-HCB-8-14 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYW IS IWC-5000 34-HCB-8-15 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HYWIS IWC-5000 1

TECO/ DAVIS br.SSE/ UNIT 1 WELD

SUMMARY

SiiEET - TABLE 1 CYSTEM CONTAINMENT SPRAY CLASS 2 . Iso No. PM 234D,REV.8 PalD NO. M-034, REV.17 PAGE 3 OF 3 o O CODE ZW SECTION ME1 MOD 5$ Z b ALLOWING PIPE DATA OF Z2M3 9I EXEMPTION INSPECTION STRESS LINE SPCOt. PIECE $WW yW WELD SUPPORT OR NRC SIZE THICKNESb (TABLE DATA NUMBER NUMBER Q8f Qb NUMBER NUMBER EXEMPTION MATERIAL Iia.) (an.) IWC-2600) POINTS REMARKS 1"-HCB-8 34-HCB-8-16 200 300 ALL ALI. IWC-1220 (b) S.S. 8 0.148 ffY/VIS IWC-5000 (continued) 34-HCB-8-17 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-8-18 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-8-20 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-8-21 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-8-22 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-8-23 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-8-24 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-8-25 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 34-HCD-8-26 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 IIY/VIS IWC-5000 34-HCB-8-27 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-0-28 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-8-29 200 300 ALL ALL IWC-1220 (b) S.S. 8 0.148 HY/VIS IWC-5000 l l

TECO/ DAVIS-BESSE/ UNIT 1 WEll)

SUMMARY

SIIEET - TABLE 1 SYSTEM CONTAINMENT SPRAY CLASS 2 . ISO No.PM 2 34C, REV.9 P&lD NO. M-034, REV.17 PAGE 1 OF 2 o O CODE 8d SECTION METHOD 52 ALLOWING P'PE.3ATA OF Z9$$ 9 EXEMPTION INSPELTION STRESS LINE SPOOL PIE ! ggg gg WELD SUPPORT OR NRC SIZE TillCKNESS (TABLE DATA NUMBER NUMBER Q o a. o0 NUMBER NUMBER EXEMPTION MATERIAL (un.) (ie,) IWC-2600) POINTS REMARKS &"-GCB-5 34-GCB-5-8 300 300 E IWC-1220 (d) S.S. 2 HY/VIS IWC-5000 34-CCB-5 H sh -EXEMPT ~ Q E-1 & 2 34-GCB-5 H-28 NON-EXEMPT c-r-1 g 2 34-GCB-5-9 300 300 A IWC-1220 (d) S.S. 1 HY/VIS IWC-50C0 ) 34-GCB-5 H-25 NON-EXEMPT C-E-1 & 2 34-GCB-5 H-26 NON-EXEMPT 34-GCB-5-10 300 300 34-GCB-5 H-29 NON-EXEMPT C-E-2 34-GCB-5 H-ll NON-EXEMPT C-E-1 & 2 34-GCB-5 H-12 NON-EXEMPT C-E-2 34-GCB-5-12 300 300 34-GCB-5 H-13 NON-EXEMPT C-E-2 34-GCB-5 H-14 NON-EXDtPT C-E-1 & 2 34-GC9-5-138 300 300 34-GCB-5 H-16 NON-EXEMPT C-E-1 & 2 34-GCB-5 H-17 NON-EXEMPT C-E-1 & 2 34-GCB-5-14 300 300 34-GCB-5 H-19 NON-EXEMPT C-E-1 & 2 34-GCB-5 H-18 NON-EXEMPT C-E-2 34-CCB-5-15 300 300 34-GCB-5 H-20 NON-EXEMPT C-E-1 & 2 34-GCB-5-16 300 300 34-GCB-5 H-21 NON-EXEMPT C-E-1 & 2 34-GCB-5 H-22 NON-EXEMPT C-E-2 34-GCB-5-17 300 300 34-GCB-5 H-23 NON-EXEMPT C-E-1 & 2 E IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 34-GCB-5 H-31 NON-EXEMPT C-E-2 9A IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000

O + TECO/ DAVIS-odSSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABIE 1 SYSTEM CONTAINMENT SPRAY CLASS 2 . ISO NO. PM 234C,REV.9 P&lD NO. M-034, REV. 17 PAGE 2 OF 2 o o CODE Zg SECTION ME1110D 2 h :) z ALIDWING PIPE DATA OF $2 g " O EXEMPTION INSPELTION STRESS LINE SPOGL PIECE gg gg WELD SUPPORT OR NRC SIZE THICKNESd (TABLE DATA NUMBER NUMBER Q o a. OO NUMBER NUMBER EXEMPTION MATERIAL (im.) (m.) IWC-2600) POINTE REMARKS 8*-CCB-5 34-CCB-5-18 300 300 34-GCB-5 H-24 NOH-EXEMPT C-E-1 & 2 = I" " I 11B IWC-1220 M S.S. 1 HY/VIS IWC-5000 C IWC-1220 (d) S.S. 3/4 HY/VIS IWC-5000 8"-HCB-4 34-HCB-4-27 200. 300 C IWC-1220 (d) S.S. 3/4 HY/ DIS IWC-5000 B IWC-1220 (d) S.S. 2 MY/VIS IWC-5000 34-GCB-5 H-38 NON-EXEMPT = C-E-2 8 *- HCC-38 34-HCC-38-15 35 200 ANCHOR 8110 NON-EXEMPT C-E-1 & 2 4 f 8 I

f" TECO/ DAVIS-bdSE/ UNIT 1 WELD SUnO4ARY SHEET - TABLE 2 CYSTEM CONTAINMENT SPRAY SYSTEM CLASS 2 ISO NO. PM 234C,REV.9 PalD NO. M-034, REV. 17 FAGE 1 OF g PIPE DATA 1 MICK-STRESS LINE SFOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER '"JMBER SUPPORT NUMBFR MATERIAL (ie.) (im.) POIN13 SYSTEM FUNCTION X Y Z C"-GCB-5 34-GCB-5-8 A S.S. 6 0.134 Discharge piping C-C EX 8 ' SURFACE from Contairunent Spray Ptumps B S.S. 6 0.134 C-G P,X 8 SURFACE C S.S. 8 0.250 C-G EX 8 SURFACE D S.S. 8 0.250 C-G EX 8 SURFACE 1 S.S. 8 0.250 C-G EX 8 SURFACE 34 <d2-5-9 2 S.S. 8 0.250 C-G EX 8 SURFACE i 3 S.S. 8 0.250 C-G EX 8 SURFACE B S.S. 8 0.250 C-G EX 8 SURFACE C S.S. 8 0.250 C-G EX 8 SURFACE 1 D S.S. 8 0.250 C-G EX 8 SURFACE e E S.S. 8 0.250 C-G EX 8 SURFACE t

-~ TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM ' CONTAINMENT SPRAY-SYSTEM CLASS 2 ISO NO.PM 234C,REV. 9 FAID NO. M-034,*REV. 17 FACE 2 OF 6 FIPE DATA TIIICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (in.) (ia.) POIN111 SYS17.M FUNCTION 1 Y Z 8"-GCB-5 34-GCB-5-10 4 S.S. 8 0.250 Discharge piping C-G EX 8 SURFACE (continued) fross Containment Spray Pumps A S.S. 8 0.250 C-G EX 8 SURFACE B S.S. 8 0.250 C-G EX 8 SURFACE j D S.S. 8 0.250 C-G EX 8 SURFACE C S.S. 8 0.250 C-G EX 8 SURFACE 34-GCB-5-12 A S.S. 8 0.250 C-G EX 8 SURFACE 4A S.S. 8 0.250 C-G EX 8 SURFACE 1 B S.S. 8 0.250 C-d EX 8 SURFACE C S.S. 8 0.250 C-G EX 8 SURFACE D S.S. 8 0.250 C-G EX 8 SURFACE

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 2 SYSTEM CONTAINMENT SPRAY SYSTEM CLASS 2 ISO NO. PM 23 4 C, REV. 9 P&lD NO. H-034, REV. 17 PAGE 3 0F 6 FIPE DATA DitCK. STHESS LINE SPOOL PIECE WELD SIZE NEM IJATA NUMBER NUMHER NUMBER SUPPOltT NUMBEH MATEHIAL (imJ (un.) POINTS SYSTEM FUNCTION X Y 8"-GCD-5 34-GCB-5-12 E S.S. 8 0.250 Discharge piping C-G EX 8 SURFACE (continued) (continued) from containment Spray Pumpa P S.S. 8 0.250 C-G EX 8 SURFACE 34-GCB-5-13B 5 S.S. 8 0.250 C-G EX 8 SURFACE D S.S. 8 0.250 C-G EX 8 SURFACE ~ SA S.S. 8 0.250 C-G EX 8 SURFACE i B S.S. 8 0.250 C-C EX 8 SUkFACE SB S.S. 8 0.250 C-G EX 8 SURFACE 34-GCB-5-13A SC S.S. 8 0.250 d-G EX 8 SURFACE 50 S.S. 8 c50 C-G EX 8 SURFACE j A S.S. B 0.250 C-G EX 8 SURFACE

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

S!!EET - TABLE 2 SYSTEM CONTAINMENT SPRAY SYSTEM CLASS 2 ISO NO. PM 234C,REV. 9 P&lD NO. M-034, REV. 17 PAGE 4 OF 6 PIPE DATA TitICK-STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (in. ) (in.) POINTS SYSTEM FUNCTION K Y Z C"-GCB-5 34-GCB-5-14 6 S.S. 8 0.250 Discharge piping C-G EX 8 SURFACE (continued) from Containment Spray Pumps A S.S. 8 0.250 C-G EX 8 SURFACE 34-GCB-5-15 7 S.S. 8 0.250 C-G EX 8 SURPACE 7B S.S. 8 0.250 C-G EX 8 SURFACE 7C S.S. 8 0.250 C-G EX 8 SURFACE B S.S. 8 0.250 C-G EX 8 SURFACE A S.S. 8 0.250 C-G EX 8 SURFACE 34-GCB-5-16 8 S.S. 8 0.250 C-G EX 8 SURFACE A S.S. 8 0.250 C-G EX 8 SURFACE 34-GCB-5-17 9 S*S. 8 0.250 C-G EX 8 SURFACE A S.S. 8 0.250 C-C EX 8 SURFACE

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 2 SYSTEM CONTAINMENT SPRAY SYSTEM CLASS 2 ISO NO. PM 2 34C, REV. 9 P&lD NO. M-034, REV. 17 PAGE 5 0F 6 FIPE DATA TillCK. S11tESS UNE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (la.) (ie. ) POINTS SYSTEM FUNCTION X Y Z 8"-CCB-5 34-GCB-5-17 B S.S. 8 0.250 Discharge Piping C-G EX 8 SURFACE { continued) (continued)- from Containment Spray Pumps C S.S. 8 0.250 C-G EX 8 SURFACE D S.S. 8 0.250 C-G EX 8 SURFACE 10 S..S. 8 0.250 C-G EX 8 SURFACE 34-GCB-5-18 11 S.S. 8 0.250 C-G E.t 8 SURFACE 11C S.S. 8 0.250 C-G EX 8 SURFACE i 11A S.S. 8 0.250 C-G EX 8 SURFACE 14 S.S. 8 0.250 C-G EX 8 SURFACE 15 S.S. 8 0.250 C4 EX 8 SURFACE 16 S.S. 8 0.250 C-G EX 8' SURFACE i i 16B S.S. 8 0.250 C-G EX 8 SURFACE

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 2 SYSTEM CONTAINMENT SPRAY SYSTEM CLASS 2 ISO NO. PM 234C, REV.9 FAID NO. M-034, REV. 17 FAGE 6 OF 6, PIPE DATA THICK. BTRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (ie.) (in.) POINTS SYSTEM FUNCTION X Y Z 8"-GCB-5 34-GCB-5-18 A S.S. 8 0.250 Discharge piping C-G EX 8 SURFACE .(continued) (continued) from Containment Spray Pumps 12 S.S. 8 0.250 C-G EX B SURFACE 8"-HCB-4 34-HCB-4-27 13 S.S. 8. O.148 Piping to containment C-G EX 8 SURFACE Spray Ring Header 13A S.S. 8 0.148 C-G EX 8 SURFACE A S.S. 8 0.148 C-G EX 8 SURFACE

TECO/DAVIb-BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 KYSTEM CONTAINMENT SPRAY CLASS 2 . ISO NO. PM 234D REV.12 PAID NO. M-034 34V.17 PAGE 1 OF 1 o o CODE g Ed Z SECTION zb$ zN METilOD gg}g ALLOWING PIPE DATA OF 4 gg EXEMPTION tr4SPECT10N STRESS LINE SPOOL PIECE ygg gg WELD SUPPORT OR NRC SIZE TillCKNESd (TABLE DATA NUMBER NUM BER Q o a. QQ NUMBER NUMBER EXEMPTION MATERIAL (in.) (sn.) IWC-2600) POINTS REMARKS 8"-GCB-10 34-GCB-10-1 450 350 33B-CCB-10 H-27 NON-EXEMPT C-E-2 33B-GCB-10 H-26 NON-EXEMPT C-E-2 2"-IICB-9 34-HCB-9-7 200 200 ALL ALL IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-9-6 200 200 ALL 'ALL IWC-1220(a) s,s, 8 0.148 HY/VIS IWC-5000 34-IfCB-9-5 200 200 ALL ALL IWC-1220(a) s.S. 8 0.148 HY/VIS IWC-5000 34-HCB-9-4 200 200 ALL ALL IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 34-HCB-9-3A 200 200 ALL ALL IWC-1220(a) s,s, 8 0.148 HY/VIS IWC-5000 i 34-liCB-9-3B 200 200 ALL ALL IWC-1220(a) s,s, 8 0.148 HY/VIS IWC-5000 t 34-HCB-9-2 200 200 ALL ALL IWC-1220(a) s,s, 8 0.148 HY/VIS IWC-5000 34-ifCB-9-1 200 200 ALL ALL IWC-1220(a) s,s, 8 0.148 HY/VIS IWC-5000 3"-HCB-9 34-HCB-9-1 200 200 ALL ALL IWC-1220(a),(d) S.S. 3 0.120 HY/VIS IWC-5000 4 E"-HCB-9 34-HCB-9-1 200 200 ALL ALL IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 9 8"-GCB-5 34-GCB-5-6 300 300 C IWC-1220(d) s,s, 2 HY/VIS IWC-5000 34-GCB-5-2 300 300 SA IWC-1220(d) S.S. 3/4 HY/VIS IWC-5000

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SIIEETF - TABLE 2 CYSTEM CONTAINMENT SPRAY SYSTEM CLASS 2 ISO NO. PM 2 3 4 D REV.12 P&ID No. M-034 EV.17 PAGE 1 OF S PIPE DATA TIIICK- & TRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (im.) (ia.) POINTS SYSTEM FUNLilON X Y Z Discharge from Contain-EX 4 0"-CCB-5 34-GCB-5-6 D S.S. 6 0.134 C4 gjygg ment Spray Pumps. &8 B S.S. 6 0.134 C-G 8 "4 A S.S. 8 0.250 c-C "#/vI8 8 "4 1 S.S. 8 o.250 C-c HY/v1S g EX 4 34-cCB-5-5 2 S.S. 8 0.250 C-c HY/VIS ,8 3 S.S. 8 0.250 C-G 8 F S.S. 8 0.250 C-G 8 34-GCB-5 H-2 C-E-2 EX 4 HY/VIS 34-cCB-5 H-32 ((2 EX 4 HY/vIS 34-CCB-5 H-1 ~ EX 4 HY/VIS 2 E S.S. 8 0.250 C-c

  1. I8 8

4 fg D S.S. 8 0.250 C-c HY/vrS 34-cCB-5 H-33 f[2 EX 4 HY/VIS C S.S. 8 0.250 C-c "NI8 &8 B S.S. 8 0.250 C-G 8 34-ccB-5 H-3 C-E-2 EX 4 HY/VIS ] 34-cCB-5 H-4 C-E-2 EX 4 HY/VIS l

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SiiEET - TABLE 2 CYSTEM CONTAINMENT SPRAY SYSTEM CLASS 2 ISO NO. PM 234D BEv.I2 PalD NO. M-034 m v. 17 PAGE 2 OF S PIPE DATA THICK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER ' MATERIAL (in.) (in. ) POIN111 SYSTEM FUNCTION X Y Z Discharge frois Contain-f."-CCB-5 34-GCB-5-5 34-GCB-5 H-34 ment Spray Pumps. C-E-2 EX 4 HY/VIS (continued) (continued) A S.S. 8 0.250 cM2 "I I8 8 f,' HY/vzS 34-GCB-5-4 c S.S. 8 0.250 c-G 34-GcB-5 H-5 C-[2 EX 4 HY/vzS f,4 B S.S. 8

0. 2'so c-G HY/v1S A

S.S. 8 0.250 C-G HY/VIS 8 ANCHOR 679 EX 4 HY/VIS 34-GCB-5-3 S.S. 8 0.250 c-G HY/VIS 3 [g* S.S. 8 0.250 c-G HY/VIS 8* 4 G S.S. 8 0.250 c-G HY/vzS f," HY/VIS r S.S. 8 0.250 c-G 4 fg E S.S. 8 0.250 C-G HY/VIS D S.S. 8 0.250 C-G I 8 ~~ EX 4 HY/VIS 34-CCB-5 H-7 2 34-GC3-5 H-6 2 EX 4 HY/VIS EX 4 HY/VIS 34-GcB-5 H-9 J 2 c S.S. 8 0.250 c-G 8 j

TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SHEET - TABLE 2 CYSTEM CONTAINMENT SPRAY SYSTEM CLASS 2 ISO NO. PM 2 3 4 D REV.12 P&lD NO. M-034 REV.17 PAGE 3 OF 5 PIPE DATA TulCK. STRESS LINE SPOOL PIECE WELD SIZE NESS DATA NUMBER NULIBER NUMBER SUPPORT NUMBER MATERIAL (m) (in.) POINTS SYSTEM FUNCTION X Y Z Disc % e f m contain-n4 t=-GCB-5 34-GCB-5-3 a s.s. 8 0.250 g,q gy/,gg (continued) (continued) ment spray Pumps. &8 34-GCB-5 u-)O C-E-2 EX 4 HY/VIs - 4 A s.s. 8 0.250 C-G n/VIs 8 "4 34-cCs-s-2 5 s.s. 8 o.250 C-G n/VIs g 34-Gca-5 u-8 [E' EX 4 uY/VIs 2 A s,s. 8 0.250 C-G "Y/YI8 8 6 s.s. 8 0.250 C-G "YIYI8 8 "4 34-GCB-5-1 7 s.s, 8 0.250 C-G HY/VIs 8 78 s.s. 8 0.250 C-G "OI8 8 34-cCa-5-2 70 s.s. 8 0.250 C-G HY/vIs g EX 4 C s.s. 8 0.2'50 C-q NY/VIs 8 11 s.s. 8 0.250 C-G 8 B s.s. 8 0.250 C-G 8 "4 7C s.s. 8 e.250 C-G HY/VIs 8 7A s.s. 8 0.250 C-G HY/VIs 8 ANCHOR 985 E~ EX 4 uY/VIs A s.s. 8 0.250 C-G 8

e TECO/ DAVIS-BESSE/ UNIT 1 WELD

SUMMARY

SilEET. - TABLE 2 SYSTEM CONTAINMENT SPRAY SYSTEM CLASS 2 ISO No. PM 234D REV.12 P&lD NO. M-034 REV.17 FAGE 4 OF 5 PIPE DATA THICK. STRESS LINE SPOOL PIECE WELD SIZE ' NESS DATA NUMBER NUMBER NUMBER SUPPORT NUMBER MATERIAL (ie.) (ie.) POINTS SYSTEM FUNCTION X Y Z Discharge from Contain-EX 4 8"-GCB-5 34-GCB-5-2 4 S.S. 8 0.250 HY/VIS (continued) (continued) ment Spray Pumps. &8 34-GCB-5-3A 12 i S.S. 8 0.250 C-G 8 13 S.S. 8 0.250 C-G &8 B S.S. 8 0.250 C-G 8 8 A S.S. 8 0.250 C-C NI8 8 13A S.S. 8 0.250 C-G 8 8 13B S.S. 8 0.250 C-G 8 Containment Spray Pump C-E-8"-HCC-38 34-hCC-38-6 ANCHOR 880 Branch Line to Borated 1&2 Water Storage Tara Recirculation Piping. Piping to containadnt EX 4 8"-HCB-4 34-HCB-4-26 9 S.S. 8 0.148 C-G HY/VIS Spray Ring Header. &8 9B S.S. 8 0.148 C-G 8 8*

  • r S.S.

8 0.148 C-c 8Y/VI8 8 E S.S. 8 0.148 C-G 8 A S.S. 8 0.148 C-G 8 &8 B S.S. 8 0.148 C-G 8 D S.S. 8 0.148 C-G HY/VIS &8 9A 8 0.148 C-G g,3, 8

TECO/ DAVIS-BcdSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 2 SYSTEM CONTAINMENT SPRAY SYSTEM CLASS 2 ISO NO. PM 2 34 D REV.12 P&lD NO. M-034 RW.17 PAGE 5 OF S PIPE DATA l SIZE T111CK-STRESS NESS DATA LINE SPOOL Fit'CE WELD NUMBER NUM8F.R NUMBER SUPPORT NUMBER MATERIAL (ia.) (ia.) POINTS SYFra.M FUNCTION X Y Z Piping to Containment EX 4 O"-HCB-4 34-HCB-4-26 C S*S* 8 0*148 O (continued) (continued) Spray Ring Header. 68 10 s.s. 8 0.148 C-G " 38 8 0"-GCB-10 34-GCB-10-1 A Decay Heat Removal S.S. 8 0.250 Cooler to Isolation C-G EX 8 SURFACE Valve. 33 S.S. 8 0.250 C-G EX 8 SURFACE 338-GCB-10-7 45 S.S. 8 0.250 C-G EX 8 SURFACE 30A S.S. 8 0.250 C-G EX 8 SURFACE l

TECO/DAV1. JESSE / UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYSTEst SPENT FUEL POOL COOLING CLASS 2 ISO NO.PN 235A,REV.16 P&lD NO.M-035, REV.18 PAGE 1 OF 2 H-033, RFV.25 of CODE ozW p' SECTION METHOD EN 2 ALLOWING PIPE DATA OF Z0j3 O EAEMPTION INSPECTIGN STRESS LINE SPOOL PIECE $WW g WELD SUPPORT OR N P.C SIZE THICKNESS IWC.' *M (TA E DATA NUMBER NUMBER cof Q NUM BER NUMBER EXEMPTION MATERIAL (us. ) (in.) POINTS REMARKS 8"-HCB-9 35-HCB-9-8 200 200 ALL ALL IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 3 5-HCB-9-1 200 200 ALL ALL IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 35-HCB-9-2 200 200 ALL ALL IWC-1220 (a) S.S. 8 0.148 HY/VIS IWC-5000 35-HCB-9-3 200 200 ALL ALL IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 35-HCB-9-4 200 200 ALL ALL IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 3 5-HCB-9-5 200 200 ALL ALL IWC-1220 (a) S.S. 8 0.148 HY/VIS IWC-5000 35-HCB-9-6 200 200 ALL ALL IWC-1220 (a) S.S. 8 0.148 HY/VIS IWC-5000 35-HCB-9-7 200 200 ALL ALL IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 10"-HCB-10 3 5-IICB-10-1 30 200 ALL ALL IWC-1220(a) S.S. 10 0.165 NY/VIS IWC-5000 6*-HCC-9 35-HCC-9-1 30 200 ANCHOR 8418 IWC-1220(a) HY/VIS IWC-5000 10"-HCB-24 35-HCB-24-4 75 100 ALL ALL IWC-1220(a) S.S. 10 0,165 HY/VIS IWC-5000 35-HCB-24-3 75 200 ALL ALL IWC-1220 (a) S.S. 10 0.165 HY/VIS IWC-5000 l 35-HCB-24-2 75 200 ALL ALL IWC-122O(a) S.S. 10 0.165 HY/VIS IWC-5000 1 35-HCB-24-1 75 200 ALL ALL IWC-1220(a) S.S. 10 0.165 HY/VIS IWC-5000 2 "-HCC-27 35-HCC-27-14 30 200 ALL ALL IWC-1220(a),(d1 S.S. 2 0.120 HY/VIS IWC-5000 3 5-HCC-27-12 30 200 ALL ALL IWC-1220(a), (d: S.S. 2 0.120 HY/VIS IWC-5000 35-HCC-27-11 30 200 ALL ALL IWG1220(a), (d: S.S. 2 0.120 HY/VIS IWC-5000

y ~ TECO/DAV BESSE/ UNIT 1 WEl.D

SUMMARY

SilEKr - TABLE I SYS' LIM SPENT FUEL POOL COOLING CLASS 2 ISO NO.PH 2 35A,REV.16 P&lD NO. N-035, REV.18 PAGE 2 ~ OF 2 -H f)33, REV.25 o o cooE zw 3 sEc110N METilOD zE$ z" ALLOWING PIFE DATA OF 6 0$g 0 EXEMPTION INSPEL"rION STRESS LINE SPOOL PtECE yww g WELD SUPPORT OR NHC SIZE TillCKNESS (TABLE DATA h NUMBER NUMBER Qof a NUMBER NUMBER EXEMPTION MATERIAL (in.) (in.) IWC-2600) POINTS REMARKS 2\\*-HCC-27 35-HCC-27-10 30 200 ALL ALL IWC-1220 (a), (d) S.S. 2 0.120 HY/VIS IWC-5000 (continued) 35-HCC-27-9 30 200 ALL ALL IWC-1220 (a), (d) S.S. 2 0.120 HY/ VIS IWC-5000 35-HCC-27-8 30 200 ALL ALL IWC-1220 (a), (d) S.S. 2\\ 0.120 HY/VIS IWC-5000 35-HCC-27-7 30 200 ALL ALL IWC-1220 (a), (d) S.S. 2\\ 0.120 HY/VIS IWC-5000 35-HCC-27-6 30 200 ALL ALL IWC-1220 (a), (d) S.S. 2 0.120 HY/VIS IWC-5000 35-HCC-27-5 30 200 ALL ALL IWC-1220(a),(d) S.S. 2 0.120 HY/VIS IWC-5000 35-HCC-27-4 30 200 ALL ALL IWC-1220 (a), (d) S.S. 2 0.120 HY/VIS IWC-5000 3*-HCC-75 35-HCC-75-3 100 200 ANCHOR 8308 IWC-1220(a) HY/VIS IWC-5000 3 *-HCC-27 35-HCC-27-3 30 200 ALL ALL IWC-1220 (a), (d) S.S. 2 0.120 HY/VIS IWC-5000 35-HCC-27-2 30 200 ALL ALL IWC-1220 (a), (d) S.S. 2 0.120 HY/VIS IWC-5000 35-HCC-27-1 30 200 ALL ALL IWC-1220 (a), (d) S.S. 2 0.120 HY/VIS IWC-5000 l 2 -GCB-10 35-CCB-10-1 450 350 ALL ALL IWC-1220(d) q.S. 2 0.203 HY/VIS IWC-5000 2 -HCC-26 35-IICC-26-2 75 150 ANCHOR 9222 IWC-1220 (d) HY/VIS !WC-5000 i l I

TECO/DAV. BESSE/ UNIT 1 WEL.D

SUMMARY

SilEET - TABLE 1 SYSTEM SPENT FUEL POOL COOLING CLASS 2 . ISO NO. Ptt 2358,REV.17P&lD NO. H-035,REV.18 PAGE 1 OF 1 14-033, REV.25 o o CODE zw Z SECTION METilOD zE$ z$ E ALLOWINC PIPE DATA OF S$g g EXEMPTION INSPECTION STRESS gww ggb LINE SPOOL PIECE WELD SUPPORT OR NRC SIZE THICKNESS (TABLE DATA aof AOh NUMBER NUMBER NUMBER NUMBER EXEMPTION MATERIAL (ie. ) (am.) IWC-2600) POINTS REMARKS 3"-HCB-36 35-HCB-36-2 150 150 ALL ALL IWC-1220(a),(d) S.S. 3 0.120 HY/VIS IWC-5000 35-HCB-36-1 150 150 ALL ALL IWC-1220 (a), (d) S.S. 3 0.120 HY/VIS IWC-5000 C"-HCB-5 35-HCB-5-1 75 150 ALL ALL IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 3"-HCC-18 35-HCC-18-2 75 150 ALL ALL IWC-1220(a) S.S. 8 0.148 HY/VIS IWC-5000 10"-HCC-7 35-HCC-18-8A 20 200 37 IWC-1220(a) S.S. 10 0.165 HY/VIS IWC-5000 10"-HCB-6 35-HCB-6-1 75 200 ALL ALL IWC-1220 (a) S.S. 10 0.165 Mf/VIS IWC-5000 35-HCB-6-2 75 200 ALL ALL IWC-1220 (a) S.S. 10 0.165 HY/VIS IWC-5000 4*-HCB-25 35-HCB-25-1 75 200 ALL ALL IWC-1220 (a), (d) S.S. 4 g0.120 HY/VIS IWC-5000 4"-HCC-29 35-HCC-29-1 15 200 34 IWC-1220 (a), (d) S.S. 4 0.120 MY/VIS IWC-5000 10*-HCB-24 35-HCB-24-5A 75 200 ALL ALL IWC-1220(a) S.S. 10 0.165 HY/VIS IWC-5000 35-HCB-24-5 75 200 ALL ALL IWC-1220 (a) S.S. 10 0.165 HY/VIS IWC-5000 10"-HCC-7 35-HCC-7-2 20 200 ANOIOR 8214 IWC-1220 (a) HY/VIS IWC-5000 10"-HCB-10 35-HCB-10-2 30 200 ALL ALL IWC-1220 (a) S.S. 10 0.165 HY/VIS IWC-5000 35-HCB-lO-3 30 200 ALL ALL IWC-1220(a) S.S. 10 0.165 HY/VIS IWC-50G.

TECO/ DAVIS-.SSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYSTEM COMPONENT COOLING CLASS 2 ISO NO.PM.236D,REV.12P&ID NO. WC36, REV.20 Pf_OE 1 OF 1 o o CODE W SECTION ML'TilOD g$ ALLOWING PIPE DATA OF z2 3 2 EXEMPTION INSPECTION STRESS LINE SPOOL PIECE ggg gg WELD SUPPORT OR NRC SIZE TillCKNESh (TABLE DATA NUMBER NUMBER Q o n. QO NUMBER NUMBER EXEMPTION MATERIAL (a) (in.) IWC-2600) POINTS REMARKS 12*-HBB-12 36-HBB-12-2 150 200 ALL ALL IWC-1220(a) C.S. 12 0.375 NY/VIS IWC-5000 12*-HBC-40 36-HBC-40-1A 150 200 A IWC-1220(a) C.S. 12 0.37E HY/VIS IWC-5000 36-IIBC-40-5 150 200 ANCHOR 8104 IWC-1220(a) j HY/VIS IWC-5000 12 *- HBB-1 36-HBC-1-3 150 200 ALL ALL IWC-1220(a) C.S. 12 0.375 HY/VIS IWC-5000 36-HBB-1-4 150 200 ALL ALL IWC-1220(a) C.S. 12 0.375 HY/VIS IWC-5000 12"-HBC-39 36-HBC-39-4 150 200 A IWC-1220 (a) C.S. 12 0.375 HY/VIS IWC-5000 36-NBC-39-7 150 200 ANCHOR 4106 IWC-1220(a) HY/VIS IWC-5000 i j i

s TECO/DA1, -BESSE/UMIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYSTEM COMPONENT COOLING WATER CLASS 2 . ISO NO.PM 236E,REV.11P&lD NO. M-036, REV.20 PAGE 1 OF 2 o o CODE zW z SECTION METHOD oj$ z4 zE E ALLOWING PIPE DATA OF g og EXEMPTION INSPECTION STRESS LINE SPOOL PIECE gwW gW WELD' SUPPORT OR NRC SIZE THICKNESL (TABLE DATA oof aoh HUMBER NUMBER NUMBER NUMBER EXEMPTION MATERIAL (in. ) (ie.) IWC-2600) POINTS REMARKS 3"-HCC-83 3-HCC-83-3 I ANCHOR S403 IWC-1220(a), (d) HY/VIS IWC-5000 3"-HCB-40 3-HCB-40-7 150 200 ALL ALL IWC-1220 (a), (d) S.S. 3 0.120 HY/VIS IWC-5000 3*-HCB-41 36-HCB-41-12 150 200 ALL ALL IWC-1220 (a), (d) S.S. 3 0.120 HY/VIS IWC-5000 36-HCB-41-13 150 200 ALL ALL IWC-1220 (a), (d) S.S. 3 0.120 HY/VIS IWC-5000 36-HCB-41-14 150 200 ALL ALL IWC-1220 (a), (d) . S.S. 3 0.120 HY/VIS IWC-5000 l 36-HCB-41-15 150 200 ALL ALL IWC-1220 (a), (d) S.S. 3 0.120 HY/VIS IWC-5000 36-HCB-41-16B 150 200 ALL ALL IWC-1220 (a), (d) S.S. 3 0.120 ItY/vls IWC-5000 36-HCB-41-16A 150 200 ALL ALL IWC-1220 (a), (d) S.S. 3 0.120 HY/VIS IWC-5000 36-HCB-41-17 150 200 ALL ALL IWC-1220 (a), (d) S.S. 3 0.120 HY/VIS IWC-5000 12"-HBB-12 36-HBB-12-4 150 200 ALL ALL IWC-1220(a) C.S. 12 0.375 HY/VIS IWC-5000 10*-HBB-12 36-HBB-12-5 150 200 ALL ALL IWC-1220(a) C.S. 10 0.365 IfY/VIS IWC-5000 12"-HBB-12 36-HBB-12-1 150 200 ALL ALL IWC-1220 (a) C.S. 12 0.375 HY/VIS IWC-5000 36-HBB-12-3 150 200 ALL ALL IWC-1220(a) C.S. 12 0.375 HY/VIS IWC-5000 12"-HBB-6 36-HBB-6-1 150 200 ALL ALL IWC-1220 (a) C.S. 12 0.375 HY/VIS IWC-5000 6"-HBB-5 36-HBB-5-5 150 200 ALL ALL IWC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000 36-IIBB-5-4 150 200 ALL ALL IWC-1220(a) C.S. 6 0.280 HY/VIS, IWC-5000 36-HBB-5-2 150 200 ALL ALL IWC-1220(a) C.S. 6 0.280 HY/VIS IWC-5000 l 4"-HBB-5 36-HBB-5-2 150 200 ALL ALL IWC-1220 (a), (4) C.S. 4 0.237 HY/VIS IWC-5000 36-HBB-5-1 150 200 ALL ALL IWC-1220 (a), (d) C.S. 4 0.237 !!Y/VIS IWC-5000 36-HBB-5-3 150 200 ALL ALL IWC-1220 (a), (d) C.S. 4 0.237 HY/VIS IWC-5000 36-HBB-5-2 150 200 12A IWC-122Ola),(d) C.S. 4 0.237 HY/VIS IWC-5000 3"-HBB-13 36-HBB-13-1 150 200 ALL ALL IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-13-5 150 200 ALL ALL IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 j

TECO/DAVs BESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE I SYSTEM COMPONENT COOLING WATER CLASS 2 ISO NO. Pit 236E,REV.llP&lD NO. M-0 3G, REV. 20 PAGE 2 or 2 o o CODE zW 2 SECTION METHOD zE$ E ALLOWING r!PE DATA OF z$ EXEMPTION INSPECTION STRESS 0ya o hwD 3g WFLD SUPPORT OR NRC SIZE YlitCKNESS (TABLE DATA LINE SPOOL PIECE NUMBER HUhBER cof o c h NUMBER hUMBER EXEMPTION MATERIAL On.) On. ) IWC-2600) POINTS REMARKS 3"-HBB-13 36-HBB-13-2 150 200 ALL ALL IWC-1220(a),(d) C.S. 3 0.216 HY/V15 IWC-5000 (cw.tinued) 36-HBB-13-3 150 200 ALL ALL IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-13-4 150 200 ALL ALL IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 6"-HBB-3 36-HBB-3-2 150 200 ALL ALL IWC-1220(a) C.S. 6 U.280 HY/VIS IWC-5000 36-HBB-3-3 150 200 ALL ALL IWC-1220(a) ~~C.S. 6 0.280 HY/VIS IWC-5000 36-HBB-3-4 150 200 ALL ALL IWC-1220(a) C.S. 6 0.280 HY/VIS IWC-5000 36-HBB-3-5 150 200 AIL ALL IWC-1220(a) C.S. 6 0.280 HY/VIS IWC-5000 12"-HBB-1 36-HBB-1-5 150 200. ALL ALL IWC-1220(a) C.S. 12 0.375 HY/VIS IWC-5000 36-hBB-1-1 150 200 ALL AIL IWC-1220(a) C.S. 12 0.375 HY/VIS IWC-5000 36-HBB-1-2 150 200 ALL ALL IWC-1220 (a) C.S. 12 0.375 HY/VIS IWC-5000 12"-HBB-4 36-HBB-4-6 150 200 all AIL IWC-1220(a) C.S. 12 0.375 HY/VIS IWC-5000 36-hBB-4-5 150 200 ALL AI.L IWC-1220(a) C.S. 12 0.375 HY/VIS IWC-5000 6"-HBB-4 36-HBB-4-5 150 200 AIL ALL IWC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000 36-HBB-4-4 150 200 AIL ALL IWC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000 36-HBB-4-3 150 200 ALL ALL INC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000 36-HBB-4-13 150 200 ALL ALL IWC-1220(a) C.S. 6 0.280 HY/VIS, IWC-5000 4*-HB3-4 36-HBB-4-2 150 200 AIL ALL IWC-1220(a),(d) C.S. 4 0.237 HY/VIS IWC-5000 36-HBB-4-14 150 200 ALL ALL IWC-1220.a),(d) C.S. 4 0.237 HY/VIS IWC-5000 36-llBB-4-1 150 200 ALL ALL IWC-1220 (a), (d) C.S. 4 0.237 HY/VIS IWC-5000 36-HBB-4-15 150 200 AIL ALL IWC-1220 (a), (d) C.S. 4 0.237 HY/VIS IWC-5000 6"-HBB-4 36-HBB-4-9 150 200 ALL ALL IWC-1220(a) C.S. 6 0.280 HY/VIS IWC-5000 36-HBB-4-10 150 200 AIL ALL IWC-1220 (. ) C.S. 6 0.280 HY/VIS 7WC-5000 36-HBB-4-12 150 200 ALL AIL IWC-1220(a) C.S. 6 0.280 HY/VIS IWC-5000 l

.~ s TECO/DAVI sESSE/ UNIT 1 WELD

SUMMARY

SHEET - TABLE 1 - SYSTul COMPONENT COOLING WATER CLASS 2 . 100 NO.PM 236F,REV.5 P&ID NO. M-036, REV.20 PAGE 1 OF-8 oU CODE o3y SECTION MEDIOD z >= z* ALLOWING PIPE DATA OF r 2$a 9$ EXEMPTION INSPECTION STRESS LIN E SPOOL PIECE $ se d 3y WELD SUPPORT OR NRC SIZE T!!ICKNESS (TABLE DATA HUMBER HUMBER Qbf aoh NUMBER NUMBER EXEMPTION MATERIAL (ia.) (ia.) IWC-2600) POINTS REMARKS 3"-HBB-3 36-HBB-3-19 150 200 .All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-20 150 200 1 IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-21 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-21B 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-21C 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY NIS IWC-5000 36-HBB-3-21A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-22 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HYWIS IWC-5000 4"-HBB-3 36-liBB-3-22 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 HY/VIS IWC-5003 36-HBB-3-F50 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 IIY/VIS IWC-5000 36-HBB-3-F49 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 IIY/VIS 1WC-5000 3"-HBB-3 36-HBB-3-26A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-26 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-F26B 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-25 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-24 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-27 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 l

TECO/DAV. BESSE/ UNIT 1 WELD

SUMMARY

SIIEET - TABLE 1 SYSTut COMPONENT COOLING WATER CLASS 2 ISO NO.PM 236F,REV.5 P&lD NO. M-036, REV. 20 PAGE 2 OF 8 U oN CODE o zi y b 3 SECTION METHOD E a z ALLOWINO PLPE DATA OF 4 2g$ 2 U EXEMPTION INSPECTION STRESS b LINE SPOOL PIECE ywW y WELD SUPPORT OR NRC SIZE THICKN ESS (TABLE DATA h NUMBER NUMBER EXEMPTION MATERIAL (6n.) (in g IWC-2600) POINTS REMARKS NUMBER NUMBER obf a 3"-HBB-3 36-HBB-3-28 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 (continued) 36-HBB-3-F29B 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-29 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-29A 150 200 All All IWC-1220 (a), (d) C.S. 3 C.216 HY/VIS IWC-5000 36-HBB-3-23 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-32 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-l!BB-3-F32C 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-323 150 200 All All IWC-1220 (a), (3) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-32A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HDB-3-31 150 200 15 IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-30 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 6"-HBB-3 36-HBB-3-23A 150 200 All All IWC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000 36-IIDB-3-15 150 200 All All IWC-1220 (a) C.S. 6 0.200 IIY/VIS IWC-5000 6"-HBB-4 36-HBB-4-29 150 200 All All IWC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000 36-IIBB-4-51A 150 200 All All IWC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000

TECO/DAVI ESSE / UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYSTEM COMPONENT COOLING WATER CLASS 2 ISO NO. PM 236F,REV.5 P&ID NO. M-036, REV. 20 PAGE 3 OF 8 o o CODE $y 3 c. SECTION METHOD b zb 2 z ALIEWING PIPE DATA OF 2$*: 9h EXEMPTION INSPECTION STRESS d 3yh LIN E SPOOL PIECE gg WEl.D SUPPORT OR NRC SIZE THICKNESS (TABLE DATA NUMBER NUMBEM c o a. AOF NUM BER NUMBER EXEMPTION MATERIAL (m. ) (ia.) IWC-2600) POINTS REMARKS 6"-ISB-4 36-HBB-4-51 150 200 All All IWC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000 (continued) 3"-IC2-4 36-HBB-4-F59A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-F59B 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-59 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000

  • 36-IIBB-4-60 150 200 54 IWC-1220 (a), (d)

C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-61 150 200 All All IWC-1220 ( 2), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-56 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-F56A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-ilBB-4-57 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-58 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-55 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-54 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/V1S IWC-5000 36-HBB-4-F53A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 IfY/VIS IWC-5000 36-HBB-4-53 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-52 150 200 All All II. -1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000

TECO/DAVI . ESSE / UNIT 1 WELD

SUMMARY

SIIEET - TABLE I SYSTEM COMPONENT COOLING WATER CLASS 2 ISO NO. P4 236P,REV.5 P&lD NO. M-036, REV. 20 PAGE 4 OF 8 d CODE oh oEy 3 SECTION METl!OD 9$" g$g$ 5 zba z ALLOWING PIPE DATA OF EXEMPTION INSPECTION STRESS $WU LINE SPOOL Fit'CE o8f c$g4 WELD SUPPORT OR NRC SIZE THICKNESS (TABLE DATA NUMBER NUMBER op NUMBER HUMBER EXEMPTION MATERIAL (im. ) (en. ) IWC-2t>00 ) POsNTS REMARKS 4"-HBB-4 36-HBB-4-52 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 NY/VIS IWC-5000 3"-HBB-4 36-HBB-4-62A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 IIY/VIS IWC-5000 36-HBB-4-F628 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-62 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-IIBB-4-63 150 200 57 IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-64 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 4*-HBB-4 36-HBB-4-F70 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 tiY/VIS IWC-5000 36-HBB-4-F69 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 HY/VIS IWC-5000 3"-11B8-4 36-t!BB-4-65 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-66 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 6*-ifBB-4 36-HBB-4-22 150 200 All All IWC-1220 (a) C.S. 6 0.280 HY/VI$ IWC-5000 36-l!BB-4-23 150 200 All All IWC-1220 (a) C.S. 6 0.280 ifY/VIS IWC-5000 36-HBB-4-36A 150 200 All All IWC-1220 (a) C.S. 6 0.280 IIY/VIS IWC-5000 36-1i88-4-36 150 200 All All IWC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000 3*-HBB-4 36-IIBB-4-44A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 1

TECO/DAVI. dESSE/ UNIT 1 WELD

SUMMARY

SilEET - TABLE 1 SYdTEM COMPONENT COOLING WATER CLASS 2 ISO NO.PM 2 36P,REV.S P&Ip NO. Me036, REV.20 PAGE 5 OF 8 od o CODE 3 zP z6 g z-5 SECTION ME1110D a ALLOWiNo PirE oATA OF $2 5 g o $ GI EXEMPTION INSPECTION STRESS LINE SPOOL PIECE gwW ggD WELD SUPPORT Oh NRC SIZE THICKNESS (TABLE DATA NUMBER NUMBER Qof QOh NUM BER NUMBER EXEMPTION MATERIAL (.n. ) (in.) IWC-2600) POINTS REMARKS 3"-HBB-4 36-HBB-4-F44B 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 (continued) 36-HBB-4-44 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 ffY/VIS IWC-5000 36-HBB-4-45 150 200 40 IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-11B8-4-46 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 ~36-HBB-4-36 150 200 F IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-41 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-F41A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-42 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-43 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 4"-HBB-4 36-HBB-4-F67 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 HY/VIS IWC-5000 36-EI B F68 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 Hf/VIS IWC-5000 36-HBB-4-37 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 PY/VIS IWC-5000 3"-HBB-4 36-HBB-4-37 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-47A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-F478 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 o t

TECO/DAVI. ESSE / UNIT 1 WELD

SUMMARY

SIIEET - TABLE 1 SYSTDI COMPONENT COOLING WATER CLASS 2 . ISO NO. PM 2 36P,REV.S P&lD NO. M-036, REV.20 PAGE 6 OF 8 oh CODE o33 3d SECTION METHOD b3 ALLowtNG PIPE DATA OF zh3 z 95" 959 EXEMPTION INSPECTION STRESS g saa d g g WELD SUPPORT OR NRC $1ZE THICKNESh (TABLE DATA LINE SPOOL PIECE NUMBER NUMBER Qo6 ooh NUMBER NUMBER EXEMPTION

MATERIAt, (ie.)

(en.) IWC-2600) POINTS REM AR KS 3"-HBB-4 HBB-4-47 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 (continued) 36-HBB-4-48 150 200 43 IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-49 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-38 150 200 All All IWC-1220 (a), (d) 'C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-F38A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-39 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-4-40 150 200 A IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 3"-HBB-3 36-HBB-3-33 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 l 36-HBB-3-39 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-F40B 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-40 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS-IWC-5000 36-HBB-3-40A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 NY/VIS IWC-5000 36-HBB-3-36 150 200 All All IWC-1220 (al Jd) C.S. 3 0.216 HY/VIS _IWC-5000 4"-HBB-3 36-HBB-3-36 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 HY/VIS IWC-5000 36-HBB-3-F48 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 HY/VIS IWC-5000 36-HBB-3-F47 150 200 All All IWC-1220 (a), (d) C.S. 4 0.237 HY/VIS IWC-5000 i

TECO/DAVI . ESSE / UNIT 1 WEI.D

SUMMARY

SIIEl:T. - TABLE 1 SYSTot COMPONENT COOLING WATER CLASS 2 ISO NO. PM 2 36F,REV.5 P&lD NO. M-036, RE7.20 PAGE 7 OF 8 oh CODE ozM 2d SECTION METHOD z E N z hIS ALLOWING PIPE DATA OF 52 $ $ 25Q EXEMPISON INSPECTION STRESS LINE SPOOL PIECE $ww gg4 WELD SUPPORT OR NRC SIZE TitiCKNESS (TABLE DATA NUMBER NUMBER OOf cop NUM BER NUMBER EXEMPTION M ATERIA1. On.) (ia.) IWC-2600) POINTS REMARKS 3"-HBB-3 36-HBB-3-35 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-F35C 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 tiY/VIS IWC-5000 36-HBB-3-358 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-35A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-34 150 200 16 IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-33 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-41 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-42 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-F438 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-43 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-43A 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS-IWC-5000 36-HBB-3-37A 150 200 All All IWC-1220 (a), (d) C.S. ,3 0.216 HY/VIS IW -.5000 6"-HBB-3 36-HBB-3-37A 150 200 All All IWC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000 3'-HBB-3 36-HBB-3-46 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 I i 36-HBB-3-F46C 150 200 All 3.11 IWC-1220 (a), (d) C.S. 3 0.216 IfY/VIS IWC-5000 36-HBB-3-46B 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000

TECO/DAV1. -BESSE/ UNIT 1 WELD

SUMMARY

SilEhT - TABLE 1 SYSTEM COMPONENT COOLING WATER CLASS 2 ISO NO. PM 236F,REV.5 P&lo NO. M-036, REV.20 PAGE 8 OF 8 oN CODE o3y EP SECTION METHOD e3 zH z ALLOWING PIPE DATA OP 9$a 2$Q O EXEMPTION INSPECTION STRE.SS $wd yW WELD SUPPORT OR NHC SIZE THICKNESS (TABLE DATA LINE SPOOL PIECE Q 8 f C O h' NUMBER NUMBER NUMBER NUMBER EXEMPTION MATERIAL (en. ) (in.) IWC-26#4 POINTS REMARKS 3"-HBB-3 36-HBB-3-46A 150 200 All All IWC-1220 (a), (d) .C.S. 3 0.216 HY/VIS IWC-5000 (continued) 36-HBB-3-45 150 200 27 IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-3-44 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 G"-HBB-3 36-HBB-3-37 150 200 All All IWC-1220 (a) C.S. 6' O.280 HY/VIS IWC-5000 36-HBB-3-8 150 200 All All IWC-1220 (a) C.S. 6 0.280 HY/VIS IWC-5000 3*-HBB-5 36-HBB-5-6 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 36-HBB-5-7 150 200 All All IWC-1220 (a), (d) C.S. 3 0.216 HY/VIS IWC-5000 ?. .l t l

TECO/DAVI . ESSE / UNIT 1 WELD

SUMMARY

SIIEET - TABLE 1 SYSTEM REACTOR COOLANT DRAIN CLASS 2 . ISO NO.PM 240A, REV. 5 P&ID NO. M-04 0 A, REV. 20 PAGE1 OF 1 o o CODE

it W g

SECTION MET 1tOD x5$ 2< ALLOWING PIPE DATA OF 2$ 9 LINE SPOOL PIECE gw g k. EXEMPTION INSPECTION STRESS WELD SUPPORT OR NRC SIZE TillCKNESd (TABLE DATA NUMBER NUMBER cof a p NUMBER NUM BER EXEMPTION MA1 TRIAL (a) (a) IWC-2600) POINTS REMARKS 3"-CCB-16 40-CCB-16-3 2500 670 ANCHOR 8261 IWC-1220(d) IIY/VIS IWC-5000 40-CCB-16-6 2500 670 34 IWC-1220 (d) S.S. 3 0.438 NY/VIS IWC-5000 3"-HCB-32 40-HCB-32-2 50 350 ALL ALL IWC-1220 (d) g,3, 3 0.120 HY/VIS IWC-5000 e.

TECO/DAt BESSE/ UNIT 1 WEll) SUMMAltY SIIEl?r - TAllt.E I 18.11 - U O

l..M 2

M W.MMM N712 MM-WA,M.M M* 1 N 1 0N CODE 0 E$ 3d SECTION ME n10D z b :) zb5 ALLOwlNG PIPE DATA OF 25$ 9s9 EXEMPTION INSPECTION STRESS 1.lN M SPOOL Pit.CK a gwg gw wgtp SUPPORT OR NRC SIZE TillCKNESS (TAlsLE DATA NllMHER NUMuER Q o e. AOh NUMBER NUMBER EXEMPTION MATERIAL (en.) ' (sn.) IWC. 2600) POINTS REMARKS 3"-IICC-45 40-HCC-45-4 100 350 Anchor 8393 IWC-1220 (d) HY/VIS IWC-5000 3"-HCB-22 40-HCB-22-1 100 350 7 IWC-1220 (d) S.S. 3 0.120 HY/VIS IWC-5000 40-HCB-22-2 100 350 All All IWC-1220 (d) S.S. 3 0.120 IIY/VIS IWC-5000 40-HCB-22-3 100 350 All All IWC-1220 (d) S.S. 3 0.120 HY/VIS IWC-5000 3"-HCC-85 40-11CC-85-1 100 350 11 IWC-1220 (d) S.S. 3 0.120 HY/VIS IWC-5000 40-HCC-85-2 100 350 Anchor 6394 IWC-1220 (d) HY/VIS IWC-5000 I i i I i i i i t i JL

TECO/DAVI.. ESSE / UNIT 1 ^ WELD

SUMMARY

SilEET - TABLE 1 SYSTEM REACTOR COOLANT DRAIN & GAS RADIATION WASTFCLASS 2 . ISO NO.PM 240C,REV.11P&(D NO. M-040A, REV.20 PAGE 1 OF 1 k o o CODE ZW Z SECTION ME1 HOD zN$ E 2 ALLOWING PIPE DATA OF O$$ Ok EXEMPTION INSPEC110N flTRESS LINE SPOOL PIECE Dwg g g h NUMBEk WELD SUPPORT OR NRC SIZE THICKNEst (TABLE DATA NUMBER N'JM BER Q O n. QO NUMBER EXEMPTION MATERLE (est) (in.) IWC-2600) POINTS REMARKS 3"-HCB-33 38-HCB-33-1 50 350 ALL ALL IWC-1220(d) S.S. 3 0.120 HY/VIS IWC-5000 3"-HSC-42 38-HSC-42-1 30 300 3 IWC-1220(d) S.S. 3* 0.120 HY/VIS IWC-5000 38-HSC-42-5 50 300 ANCHOR 8228 IWC-1220(d) HY/VIS IWC-5000 3"-HSC-71 40-HSC-71-1 50 300 26 IWC-1220(d) S.S. 3 0.120 HY/VIS IWC-5000 40-HSC-71-2 50 300 -.sCHOR 9 230 IWC-1220(d) HY/ iris IWC-5000

-t .M a .4 b .' W< c 5 m -M ri ag s I H=h a o i N Z = a hg ~ ! Es E E-4 5 3 3 'T b z-a a-C. s1 '1 1 m. o 0-Z e- - ' b $~ m n .h 3b ~ .s a .J g 5 E 9 9 a e = =

  • 2 o

.s h n +- e. ugt, ~ ) a p@ .4 .V ., ip< p s iWi $ p g+ g MAld W/yo \\ igy py_ y g i

Subject:

Dy[gy ggj;p yggy y pgg,,q,,gg3) Contract - l?2 W/-Ol'C val.VE5, + U0 ELD NCh Sketch by WM Pst'A/ SUPPLEMENTS REPORT OF INSPECTION Sketch No. Revision Number Attachment E ii c , i., i}}