Other: 05000270/LER-1982-002, Forwards LER 82-002/01T-0.Detailed Event Analysis Encl, 05000270/LER-1982-002-01, /01T-0:on 820122,three Core Support Assembly Thermal Shield Bolts Found W/Heads Broken Off & Shock Pad Y-2 Attachment Bolts Discovered Broken.Caused by Intergranular Stress Corrosion Cracking.Pad Removed, ML17318A294, ML19240C002, ML19256A166, ML19256A171, ML19274D226, ML19274E547, ML19309G772, ML19317F583, ML19323D082, ML19323D085, ML19326A405, ML19326A415, ML19329A858, ML19329A909, ML19329A920, ML19329B774, ML19340E122, ML19345F245, ML19345F247, ML19345G512, ML20011B254, ML20023A486, ML20024E088, ML20028D207, ML20040H182, ML20040H185, ML20041C218, ML20041G421, ML20052F377, ML20052F389, ML20054C645, ML20054C957, ML20065B814, ML20073S274, ML20236J661
|
MONTHYEARML19326A4051977-04-22022 April 1977 Grants Relief from ASME Requirements for Proposed Inservice Testing Program for Pumps & Valves for Defined Period of Time.Addl Info Needed for Request for Relief from ASME Code Requirements Under Section 4.0.5b of Tech Specs Project stage: Other ML19326A4091977-04-22022 April 1977 NRC Guidance for Complying W/Certain Provisions of 10CFR50. 55a(g), Inservice Insp Requirements. List of Info Required for NRC Review of Inservice Insp Review & Testing Program Encl Project stage: Approval ML19326A4151977-04-22022 April 1977 NRC Guidelines for Excluding Exercising (Cycling) Tests of Certain Valves During Plant Operation Project stage: Other ML19329A8581977-06-27027 June 1977 Responds to NRC 770422 Request.Forwards Pump & Valve Test Program, for Compliance w/10CFR50.55a(g).Additions & Changes to Program,Which Meet Code Testing Requirements Will Be Implemented.W/O Encl Project stage: Other ML19329A9091977-11-22022 November 1977 Responds to NRC 770422 Request Re Facility Inservice Insp Program Compliance w/10CFR50.55a(g).Forwards Program for ASME Class 2 & 3 Components.W/O Encl Project stage: Other ML19329A9201977-11-22022 November 1977 ASME Section 11 Weld Examination Program for Facility: Inservice Insp Program Project stage: Other ML19329A8551978-01-0505 January 1978 Responds to NRC 770104 Request.Forwards Second Transmittal of 770627 Rept, Pump & Valve Test Program, for Docketing. W/O Encl Project stage: Request ML19317F5831978-01-0505 January 1978 ASME Section 11 Pump & Valve Test Program for Facility Project stage: Other ML19329B7741978-01-0606 January 1978 Notifies of Receipt of Util Request for Relief from Requirements of ASME Code Section 11,1974 Edition W/Addenda Through Summer 1975.Forwards Info Re Proposed Testing Program.W/O Encl Project stage: Other ML20236J6611978-03-29029 March 1978 Advises That Submittal of Second 40 Month Insp Period Plan Rescheduled to 780801.Submittal Date Changed from 780601 Due to Unanticipated Demand on Available Engineering Manpower Project stage: Other ML20112H3841978-08-0303 August 1978 Forwards Description of Planned Inservice Insp & Testing Program for Next 40-month Period & Three Sets of Modified Piping & Instrumentation Drawings,Including Applicable Components,Per Project stage: Request ML20147B6621978-10-0303 October 1978 Forwards Proposed Amend to Tech Specs Which Will Upgrade the Insvc Inspec Requirements Per 10CFR55a(g)(4)(ii).Proposed Changes Rely on Standard Tech Specs Project stage: Request ML19256A1711978-10-19019 October 1978 Notice of Granting of Relief from ASME Section XI Inservice Insp (Testing) Requirements Project stage: Other ML19256A1661978-10-19019 October 1978 Responds to Requesting Relief from Certain Requirements of Section XI of ASME Boiler & Pressure Vessel Code.Preliminary Review by NRC Finds Compliance W/Codes Would Cause Unusual Hardship & Are Waived Project stage: Other ML20062F4091978-12-12012 December 1978 Responds to 781201 Request for List of Plant Mod Being Made to Implement the Fire Hazard Analysis Rept.Fire Extinguishers Being Added to 13 Rooms & Wet Sprinkler or Spray Sys Being Added or Upgraded Project stage: Request ML19274D2261979-01-0303 January 1979 Grants Relief from Certain Inservice Insp & Testing Requirements of the ASME Boiler & Pressure Vessel Code, Section 11,pending Review Completion.Determines That Environ Statement Re This Action Is Not Necessary Project stage: Other ML19274E5471979-03-0909 March 1979 Requests Confirmation That Meb Will Not Review Inservice Testing Program in the Same Way They Review Inservice Insp Program.Asks for Name of Lead Reviewer of Testing Program Project stage: Other ML20244A5731979-03-28028 March 1979 Forwards Summary of 790222 Meeting Re Inservice Insp & Test Program.Summary Identifies Addl Info Required to Complete Review of Requested Relief from Certain ASME Code Requirements Project stage: Meeting ML20244A5791979-03-28028 March 1979 Summary of 790221 Meeting W/Util at Site Re Inservice Insp & Testing Program Project stage: Meeting ML19308A4531979-08-0808 August 1979 Discusses Review Re ASME Code,Section XI Exemption of ECCS Components from Inservice Insp Based on Water Chemistry Control.Water Chemistry Control to Minimize Stress Corrosion Is Unacceptable Basis for Exemption from Insp Project stage: Approval ML17318A2941979-09-14014 September 1979 Proposes Mods to Inservice Insp & Inservice Testing Program Review Responsibilities to Minimize Duplication of Effort at NRC & Maximize Contractor Review Activities.Sister Nuclear Facilities Should Be Managed by Same NRC Ofc Project stage: Other ML19309G7721980-05-0101 May 1980 Submits Addl Info Re Inservice Insp & Testing,In Response to NUREG-0411 Requirements.All Inservice Examinations Will Be Performed Per 1974 ASME Code XI W/Addenda Through 1975. Requests Relief from Hydrostatic Test Temp & Test Duration Project stage: Other ML19323D0821980-05-15015 May 1980 Forwards Updated Inservice Insp Program for Pumps,Valves, Welds(Including Supports,Components & Bolting) & Sys Pressure Tests Project stage: Other ML19323D0851980-05-15015 May 1980 Updated Inservice Insp Program for Pumps,Valves,Welds (Including Supports,Components & Bolting) & Sys Pressure tests.Twenty-three Oversize Drawings Encl Project stage: Other ML19345B2191980-11-14014 November 1980 Forwards Branch Questions & Comments & Request for Addl Info Re Util 800515 Revised Inservice Insp Program.Comments Will Form Basis for 801119-21 Working Session at Site Project stage: RAI ML19340E1221980-11-30030 November 1980 To Inservice Insp Program Project stage: Other ML19340E1191980-12-15015 December 1980 Forwards Revision to 800515 Inservice Insp Program.Changes Reflect Results of 801119 & 20 Meetings W/Nrc Onsite Re Lower Head Weld Insp & Requirements in 1977 Edition Through Summer 1978 Addenda of Boiler & Pressure Vessel Code Project stage: Meeting ML19345F2471981-01-27027 January 1981 Amend 2 to Inservice Insp Program Project stage: Other ML19345F2451981-01-27027 January 1981 Forwards Amend 2 to Facility Inservice Insp Program, Replacing 790606 Amend 1 Submittal.Requested Relief Does Not Affect Public Health & Safety.Requests Approval Project stage: Other ML19345G5121981-03-31031 March 1981 Forwards Editorial Revisions to Inservice Insp Program Project stage: Other ML19240C0021981-03-31031 March 1981 Inservice Testing Program for Pumps & Valves at Davis-Besse Nuclear Power Station - Unit 1 (Docket 50-346) for Period Nov 1977 Through Nov 1987, Safety Evaluation Project stage: Other ML20011B2541981-11-24024 November 1981 Forwards Info Re Class I Inservice Exam Areas Not Receiving Full Code Exam During 1981 Maint Refueling Outage.Areas Include Lugs,Reactor Recirculation Sys Vessel Nozzles,Piping Butt Welds & Recirculation Pump Studs Project stage: Other 05000270/LER-1982-002-01, /01T-0:on 820122,three Core Support Assembly Thermal Shield Bolts Found W/Heads Broken Off & Shock Pad Y-2 Attachment Bolts Discovered Broken.Caused by Intergranular Stress Corrosion Cracking.Pad Removed1982-02-0505 February 1982 /01T-0:on 820122,three Core Support Assembly Thermal Shield Bolts Found W/Heads Broken Off & Shock Pad Y-2 Attachment Bolts Discovered Broken.Caused by Intergranular Stress Corrosion Cracking.Pad Removed Project stage: Other 05000270/LER-1982-002, Forwards LER 82-002/01T-0.Detailed Event Analysis Encl1982-02-0505 February 1982 Forwards LER 82-002/01T-0.Detailed Event Analysis Encl Project stage: Other ML20041C2181982-02-0808 February 1982 Notice of Granting Relief from ASME Section XI Inservice Testing Requirements Project stage: Other ML20041C2151982-02-0808 February 1982 Safety Evaluation Re Inservice Test Program & Granting of Relief from ASME Code Section XI Inservice Testing Requirements Project stage: Approval ML20041C2071982-02-0808 February 1982 Forwards SER & Fr Notice Re Inservice Test Program & Granting of Relief from ASME Code Section XI Inservice Testing Requirements.Approval of Relief Expires on 850508 for Unit 1 & on 870401 for Unit 2 Project stage: Approval ML20040H1821982-02-16016 February 1982 Submits Editorial Revisions,Revision 3,to Inservice Insp Program Project stage: Other ML20040H1851982-02-28028 February 1982 Inservice Insp Weld & Support Insp Program,Revision 3, Editorial Changes Project stage: Other ML20041G4211982-03-12012 March 1982 Requests Addl Info Re Inservice Insp Program Relief.Info Should Be Forwarded to Science Applications,Inc,Within 30 Days of Ltr Project stage: Other ML20054D3051982-04-0606 April 1982 Requests Addl Info Required for Review of Inservice Insp Program.Response by 820611 Requested Project stage: Approval ML20054C6451982-04-0707 April 1982 Approves Util 800501 & 820311 Requests for Relief from 1974 Edition of ASME Section XI Code Re Required Inservice Insp Hydrostatic Min Test Temp of 100 F & Hold Times Project stage: Other ML20054C9571982-04-0808 April 1982 Notice of Violation from Insp on 820101-0228 Project stage: Other ML20052F3861982-05-0505 May 1982 Safety Evaluation Re ASME Code Section Xi,Inservice Insp Requirements.Granting of Relief Does Not Authorize Change in Effluent Types or Total Amounts Nor Increase in Power Level & Will Not Result in Significant Environ Impact Project stage: Approval ML20052F3891982-05-0505 May 1982 Notice of Granting Relief from ASME Code Requirements Project stage: Other ML20052F3771982-05-0505 May 1982 Advises That Sections 3 & 4 of 800515 Revised Inservice Insp & Testing Program Per ASME Boiler & Pressure Vessel Code Section XI of 1977 Edition Through Summer 1978 Addenda Acceptable for Remainder of 120-month Insp Interval Project stage: Other ML20023A4861982-09-0202 September 1982 Ei Hatch Nuclear Plant Units 1 & 2 Inservice Insp Program, Technical Evaluation Rept Project stage: Other ML20065B8141982-09-15015 September 1982 Advises of Exam Areas Not Receiving Full Code Exam During Inservice Insp Activities Conducted During Maint/Refueling Outage & Forwards Lists of Exam Limitations.Welds Receiving Limited Coverage Listed Project stage: Other ML20028D2071983-01-0707 January 1983 Comments on Upgrading Inservice Insp/Inservice Testing Program.Upgrade Requires Extensive Rewrite Due to Significant Changes in 1980 Edition of ASME Section XI Code from That Currently Used.Submittal Delayed Until 830801 Project stage: Other ML20028G1681983-02-0202 February 1983 Forwards Addl Info on Modified 821214 Code Relief Request 1 Revising Inservice Testing Program.Basis for Request Listed. Request Per ASME Section XI Iwv Re MSIVs MS-100 & MS-101 Project stage: Request 1980-12-15
[Table View] |
Text
-
-.-..-r-,.
Dist
- ution, d
Docht Fil7
!!RC PDR J. P. Knight Local P0q G. Foss APR 2 21977 LUR 1 File G. Lear
- n. B. Vassallo P. '.fagner F. J. Milliams J. Stolz
.f Locket 130. 50-346 L. Engle E. Hylton ACRS (16)
ELD Toleco Edison Cuppany IE (3)
ATm: nr. ' Lowll C. Foe H. Smith Vloe President, Facilities Dwelogrnent R. S. Boyd D. Eisenhut Edison Plaza 30 M ison A m ue J. R. Buchanan T.B.Abernatd,MSIr c'.
Toledo, Ohio 43652 0**D
OO W
a SUtMD.7. : RCLIE2' MGt IES RECUIECC.?J CF T!IE ASIE i.)ILER IJiD PRC3SUrc VE35EI. CCDS, SECfIO*1 XI (OAVIS DESSE 2CID.R MiER S"ATIOi-1, WIT 1)
We nr.va expleted our review cf ycur propoced inservice inamction aM testing progran for Cavic 8 esse, Unit I described in tne enclosure to your letter cated 2ve:ter 9, Iv75, and your request for relief frca ene requiremnts of tne ASME coller ano Pressure Vescal Code,Section XI.
Based on our review, we nava concluded tnat your proposed inservice testing program for pumps caa valves is acceptacle fcr tne 1ialted
- erlil of tim frca tne-date of issuance of tm f
- cility operating license to the start of f acility caarrelal omraticn. In lieu of the surveillance requiremnes of section XI of tne laE 0:xie, you snall perfora cne curveillance descriced in the enclosure to your letter dated aov e r 9, 1976, except that pucps shall be tested every 31 days to conform to our requiremnts instead of the 92 days wnien ycu procosed in your runnittal.
n the bacis that ycur procosed program is acceptr.cle and snall ce implemnted for rne period of time from issuance of the operating license to start of facility corrercial operation, w nereoy grant relief frca tne A3:tB Code requirements pursuant to Section 4.0.5a or tre plant recanical Specitications.
iiita regard to your raquest for rellef from the A3ME Code requiremnts Lv;osed oy Section 4.0.5o of rne plant Tecnnical Specifications for the pericd of time following the start of facility comnercial operation, w nave ceternirec that your request does not include sufficient inter-lt.arica for us to. ake a determination pursuant to 10 CFR 50.55a(g)(6)(i) 80020 @ 9 M 4
'errec a >
eumwaaes >
oavs >
NRC PORM 518 (9 70' NRCM 0240
' W u. a. aovsenwant >= =rewo orrisse vere-eae.ea4
. ~..;
.e 1
APR 2 2 1977 Ioledo Edison Company that,E<c Code requiresaents are impractical for tne areas of tne facility for whicn pu are requesting relief within the limitations of design, geometry, and materials of construction. We progrom which you suinitted (iiscusses caly those portions of the ASM Code wnica you have cetermined to De practical.
In order for us to make an evaluation of your requent for relief pursuant to 10 CPR 50.55a(g)(6)(1) for tne period of tire af ter the start of comoercial operation, you will need to provide inrormation to stsport ycur oeterminations of these items of insyction and testing wnich are deeml to be bpractical for the facility. we specific information tnat we will need is provided as Enclosures 1 and 2 of th%1etter.
With regard to the request for rel fel, tne :rtC nas received a nudoer of inquiries from J icensees regarding acceptacle ::vthods for complying witn 10 CF3 50.55a(g). In general, tnese incuirles have been directM toward tnree major areas relative to ccep] lance witn the regulation:
1.
te determination of whien A3:2 Boiler and Pressure Vescel Coce cdition and,vxierda are applicacle for any updatec inservice inspection or testing program.
2.
me requirement to conform the wcnnical 2pecifications to a revisec program, and 3.
me process or Octaining reliet fr::e,u.4 ede requirecents four.d to be impractical., "icc Staff anidance for Cc= plying witn Certain Previsions of 10 CFR 50.55a(g), Inservice Increction Foquirerents," descrices ene cajor provisicna of tre revbeu regulation, adcreases the areas of 1icensee concern listed above, and provices guidance en information wnica w will need to evaluate req.:esta for rellet frec,mc Coae requirewnts enat are determined to t# icpractical.
As discucced in Inciccure 1, you should nutr.i*. a deceription of your planned inservice inspection sna testing progrecs, as ell as any relicf fracz AE Code requirements determined to be impractical for the facility, as far in advance as posalble cf tne start of any 40-acatn inservice inspection period, or 20-month puz p and valve testing program.
In additicn, we mid 1ike to empnasire an intortant ?oint rogardbg the < TOE Code Section XI require::ents to test selectec pumos and valves that are rw incorporated in 10 CFR 50.55a(g): 2e.%E Code Section XI D**}D *}D[3'l$
o J uU S Inl a o o Ju OPPtCE >
9 URN A.eE W OATE W
- " "=a'aa ""J"""*.*"'e = ' - - -a
E
\\,
b APR 2 21977 Toledo IMison Company requirer.ents apply only to selected valves and pumps that can be tested witnout placing tne plant in an unsafe condition. You sbould exercise care in planning your testing progra:s to ensure that no test will ce conaucted wnlle tne plant is in an operating : node tnat woulo make it vulneraale to a test error or a test failure. Particular attention should be directed toward tne valve exercising (cycling) rests.
In this regard, some baalc guidelines for excluding exerciaireg (cycling) tests of certain valves during plant operatica are contained in.
Valve leakage tests and otner valve and pung tests required by the ASdC Code should ce reviewed for eacn eccpenent, rela-tive to each plant operating =ade, to assure tnat no test will nave an a:: verse 1::qnce on plant safery.
If you have any furtner questions regarding inplementation of 10 CFR 50.55a(g) at your facility, please contact us.
Sincerely, Original agned by IL C. DeYoung
};,. Pager 5. Ecyd, Directcr T Division of Project fianagment Office of ;ns: lear mactor regulation inclosures:
1.
IGC :.itaff Guidance for Cceplying witn Certain Provicien of 10 CFR 50.55a(g) 2.
Gaidelinea for ::xcluding Exercising (Cycling) Tests of Certain Valves During Plant Operation cc w/ enclosures:
tr. Donald H. dauser, Esq.
2ne Cleveland Electric Illtrainating Ctx::pany P. O. Ecx 5000 Cleveland, Olio 44101 Gerald Charnoff, Esq.-
- q w
't Snaw, Pittman, Potts and Trowbridge~
O 1800 M Street, N. W J
Washington, D. C.
20036 oc w
teslie tienry, Esq.
Fuller, Seney, Benry and Dodge 300 Hadison Avenue toledo, Onto 43604
,j:
LWRel M L'Al AD/ LWR DSS fk DP
., m.
ley @e'/Yed
- JStM3, DBVas M io'MD MMiaht dovh
,,,,,,,,,e, 4/hD/77
,_440/77 4/sA77 4/22L77 5 4/M/77-
'ajpf 77
~'
NRC FORM 31s (9 76) NRCM 024L_,.
Tr u. s. soveme,ese remnme orms. ene.ees.ees
- ,