ERC FORM 366 U.S. NUCLEAR REGULATORY CoMMISSloN UCENSEE EVENT REPORT

.[- .;

CONTROL SLOCK: l l l l l l lh (PLE ASE PRINT OR TYPE ALL REQUIREO INFoRMATION) 1 6

[ R l I8 l9 L l Q l A l 0 l 2 ISl@ 0 l0 l0 l- l0 l0 l0l-l0l0l0l@lhIIl1l1l1l@l 7 LICENSEE CODE 14 LICENSE NUMSER 25 26 LICENSE TYPE 40 l

$7 CA r Sa l@

CON'T

  • g l'gy l L )@l 015 l0 lo lo 12 l6 15 l@l 01211191810 I@l 013REPORT 74 75 l o I DATE 6181080l@

7 $ 60 61 DOCKET NUMBER td 69 EVENT DATE EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h

[TITI l While performing the Automatic Blowdown Logic Test, nrocedure OMS 700-1. automatic l

- pTTT'l l blowdown timer 287-105A took 122 seconds to time out. This time was in excess of I g[ Technical Specification Table 3 2-2 allowable limit of eaual to or less than 120 ,

Lo i s] l seconds. The redundant 287-105B timer actuated in 112 seconds. Thus. the functional 1 o e l requirements of the Automatic Pressure Relief system aid have performed within the l gl design time f rame if initiated. 1 ITili'l I I E CODE SUSC E COMPONENT CODE SUSCODE S E 7

O g g

lIl 8 l@

9 to 13

@ 12

@ l R l E l L l A lY lX l@ l Ml@ 20W @

13 18 19

_ SEQUENTI AL OCCURRENCE REPORT R EVISION LER EVENT YEAR R EPORT NO. COCE TYPE N O.

@ ,ag/RO " l 8 1 01 21 22 1-1 23 10101 4 1 24 26 Ld 27 1 01 31 28 29 W30 L--J 31 10 I 32 N ACTC ON PL NT HOURS S8 IT FOR 8. SUPPL 1 MANUF CTURER gl34 Zl g

,33 lhZl@

3 l36Z l@ l0l0l0l0l 31 40

[N 41 l@ l42Y l@ lN 43 l@ l44G l 0 l 8 l 0l@

47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h g ] The cause of this occurrence was instrument set point drift. The 287-105A timer l i i l was adjusted and tested under work reauest number Q 03655 on February 25. 1980. The I

, ., l corrected time for the 287-105A timer was verified to be 100 seconds. l L' l.3_1 I I EE)8 I9 7 80 i

STA  % POWER OTHER STATUS IS O RY DISCOVERY DESCRIPTION NA lB[gl Logic Test

['TTs1 W @ l' 7

I I Ol@l l l 8 tEnviTY CO0 TENT r.rtEASEo Or RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE 1 6 NA

@ l Zl@l l l NA l PERSONNEL EXPOS ES NUM8ER y l 0 l 0 l 0 lhl TYPE @l Zl DESCRIPTION NA l PERSONNE t iN;u' RIES NuM8ER oESCmP riONh NA L'_h.]

7 8 9 I 01010 l@l12 11 l

80 LOSS OF OR OAMAGE TO FACILITY TYPE DESCRIPTION 1 9 NA 7 8 9

@l10 l 60 IS

  • NA Q [SE @lDE CRIPTION l lllllllllllll{

7 8 9 to 68 69 80.S NAME OF PREPARER J. Vahrenwald 8003 200 HSPHONE: 309-654-2241 ext. 195 o i