I 02h02 SNUBBER TESTING SCOPE April 8,1998 ATTACHMENT 2 QUAD CITIES NUCLEAR POWER STATION UNIT 2 PLANNED MAINTENANCE OUTAGE (Q2P02)

TECHNICAL SPECIFICATION 3/4.8.F SNUBBER FUNCTIONAL TESTING SCOPE QUAD CITIES UNIT 2 TECH SPEC (SAFETY RELATED) SNUBBER POPULATION IS 129 SNUBBERS A. FUNCTIONAL TESTING SCOPE 1.

TECHNICAL SPECIFICATION 10% SAMPLE AND SERVICE LIFE MONITORING SAMPLE:

a.

Testing will be performed with the following procedures:

e QCAP 0410-05 i

QCTS 0750-05 b.

Breakdown of the sample is:

6 snubbers in the Drywell l

6 snubbers in the Reactor Building I

e 1 snv%er in the Turbine Building e

c.

System breakdown of the 10% sample:

Tech Spec Snubbers:

TECH SYSTEM MM SERIAL SNUBBER ISI NUMBER LOCATION DRAWING SPEC NWR#

TYPE AND NUMBER SEE 2-032 0300 980031326-01 8515 PSA-1 NON-CODE DRYWELL iST LEVEL M-1053-BF SHT.1

&4 2 050 3000 980031932-01 7931 PSA-35 NON-CODE TURBINE BLDG M-10200-1 SHT.

1,2,3

]

2-056*

3000 980031935-01 61300/63 LISEGA-5/10K 3001 A-M-102.3 DRYWELL 2ND LEVEL M-328E SHT. 3 1

f 2-065 3000 980032104-01 61308/49 LISEGA-4 NON-CODE DRYWELL iST LEVEL M-328F SHT.15 2-072*

3000 980032105-01 61310/37 LISEGA-6 3001 D-M-101.2 DRYWELL 2ND LEVEL M-328H SHT. 2

)

l 2-083*

1000 980032379-01 16588 PSA-3 1025-M-102.1 DRYWELL 1ST LEVEL M-1022D-8 SHT.

l A&B 1.2.3 2-085*

1000 980032381-01 24460 PSA-3 1025 M-101 DRYWELL 1ST LEVEL M-1022D-9 SHT.

A&B 1.2.3 l

2-093 1000 980032383-01 9254 PSA-35 NON-CODE REACTOR BLDG M-1802-13 SHT.

BASEMENT 1.2.3 2-101 1000 980032106-01 779 PSA-100 NON-CODE REACTOR BLDG M-1802-05 SHT.1.2 l

BASEMENT 2-130*

1400 980032107-01 10394 PSA-10 1403-W 207 REACTOR BLDG (TOP M-181135 SHT.1 &

I A&B OF TORUS) 2 2-135 1300 980032110-01 7748 PSA-10 NON-CODE 2B CORE SPRAY M-1814-08 SHT.1, CORNER ROOWI

&2 2-137 1000 980032111-01 3299 PSA-1 NON-CODE REACTOR BLDG (TOP M-1984 OF TORUS) 2 144*

1000 980032112-01 7717 PSA-10 1016C-M-201.1 2B RHR CORNER M-1806-12 SHT.1 &

ROOM 2

9004290124 980424 PDR ADOCK 05000254 pAGE 10F 2 p

PDR

i

. Oh02 SNUBBER TESTING SCOPE

/Y' Y~

~

/////k

/)

Date:

' 6Afchsel'A.JEsf5peo -

I Snubber Coordinator x2165 Pager# 354

{

Engineering Programs Group l

i I

'Q979 CoJperse -~

Oh, W

l 2

D 1 M ate:

'I

~