LER 79-009/03L-0 on 790203:bed Plate Drain Valves AO 1-4999-57,58 & 60 Did Not Fully Close.Caused by Corrosion & Failure of Internal Return Springs.Springs Replaced & Valves Satisfactorily Retested
ML19282B814
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 02/28/1979
From: Robert Murray
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19282B812 List:
References
LER-79-009-03L-01, LER-79-9-3L-1, NUDOCS 7903160214
Download: ML19282B814 (2)


Text

- -

a , n e CO

,N'THOL OLOCK: l i

l l l l l l e

. (PLEASE PRINT OR TYPE ALL REQUIRCD INFoRMAllONI ioltj l l' l L l Q -l A lD l1 l@l 0 l 0 l 0 l- l0 l0l0l-l0l0l0 l@[ 25 426l l l LICENSL 1 l 1 TYFE l 1 JOl@l b7 C Al f :>8l@

8 9 LICENSEE CODE 14 15 LICENSE NUMBER CON'T

'il

. "Ef]

c lLI@l0l5l01010l2 .,

15 I4 @l 0 I 2w ! 0 13 m: y.. . .m . ...m17 19 @La oi 2 I s,.,.m 2 I a 17 19J@

E'.ZT ':~

i m:01. .: 2'M' E C7d:CaENCE.: h l While performing surveillance procedure 0.0S 30-2, RHR Service Water Vault Bed Pla_te l l

Drain Check, bed plate drain valves A0 1-4999-57, 58 and 60 did not fully close on I

]l their respective float switch signals or on loss of instrument air to the valve j operators as required by Technical Specification 3.5.H. A check valve, in addition j 7g g


)

u -l._ __..:. to each ai r-ope ra ted va lve , is installed in each bed plate drain line and would j have prevented any backflow from outside the vaults oi from one vault to another  ;

._ in the event of a flood. l

,, a

'r 3 T E si c a.
.12 Ce"E C O N .

COCE C00E A G'. 0E CO. ANE*JT CODE SLdLL 32 i . .

~'-

d

!S !

3 BI@ l Eh ! B ih I 1J 11 1.' IJ V  !

A ! L'V I E'X_! h IE ' 3 _PJ )

1 -> 1> le SEQUENTML CCCU R R E '.C E P E G T D E '- '8 trn EVENT YEAR REPORT r.O. CCCE TYPE NO

@ggg,no 17 19 I l-l 101019l l/l l0l3l lLl 30 I --J g l0l 32

_. 21 22 23 24 26 27 28 29 31 ACT;ON FUTURE EFFECT SHUTDOWN ATT A C HV E NT NP R O-4 PR!YE COMP. CO?.1PON E N T TAKEN ACTION ON PLANT METHOD HOURS SUBMITTED FORMbUB. SUPPLIER MANUFACTURER l33 Bl@W@ ln Z l@ l36Z l@ l 0 l0 l0 l0 l l41 Y l@ l42 Yl@ l43Nl@ l Fl 1l2l8l@

34 3/ 40 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h li lo l l The i n te rn a l return springs had corroded and failed. The resultino lacl. of valve l li g i; [ plate tension prevented the normally open valves from properly closino and seatino. I

~

g; The valve return springs in all the Unit One RHR service water bed plate drain valves l

, g we re replaced. The bed plate drain valves were satisfactory retested on February l 3

14, 1979 7

8 9

[ 60 STA S  % POWER OTHER STATUS Dis V iY DISCOVERY DESCRIPTION 7

1 5 8 9 l Hl@ l 0 l 0 l012l@l to 13 HA 44 l l45 B lhl46 Routine Testino 80 l

ACTIVITY CONTENT RE LE ASE D OF RELEASE AMOUNT OF ACTIVITY LOCATION OF F1ELEASE

1 c 8 9

[Zj @ l 10Z l@l NA l l 45 NA 60 l

7 t1 44 PERSONNEL EXPOSURES NUMBER TYPE NA I: 1 7

i 8 9 l 0 l 0 l0 l@[ Z]QlDESChi

11 12 13 TION EO l

PERSONN E L INJURIES NUV8ER DESCRIP TION HA' H 1 819 l 01 0l 0l@l12 7 11 CO l

LOSS OF OR DAYAGE TO FACILITY TYPE DESCR!P flON NA

[1 l o8 9l Zl@l10 7 E0 l

l%UED PunLICITY DE SCRIPTION 4

  • 790316Upa '

. Nnc Usc ONtY a.L_1L"181 "A I i lIllllill'Il:

T 8 3 10 G8 63 80 5 N A*.!E OF PREPARER DHONE:

N i

4 -

I. LER NUMBER: LER/R0 79-09/03L-0

11. LICENSEE NAME: Commonwealth Edison Company Quad-Cities Nuclear Power Station Ill. FACILITY NAME: Unit Two IV. DOCKET NUMBER: 050-254 V. EVENT DESCRIPTION:

On February 3,1979, while performing surveillance procedure QOS 30-2, RHR Service Water Vault Bed Plate Drain Check, bed plate drain valves A01-4999-57, 58, and 60 did not fully close on their respective float switch signals or on loss of instrument air to the valve operators. As required by Technical Specification 3.5.H., these valves are to close upon the loss of air or power, high level in the equipment drain sump (signaling a possible flood), or high level in the vaults. Work request number 597-79 was written to repair the 1-4999-57, 58 and 60 valves.

There has been one previous occurrence of an RHRS service water pump drain valve failure at Quad-Cities Station documented in R0 50-254/77-16.

VI. PROBABLE CONSEQUENCES OF THE OCCURRENCE:

The safety implications of this occurrence are minimized by the fact that each of the subject valves has a check valve located between it and the bed plate drain. This would have prevented any backflow into the RHRS service water pump vaults from outside the vaults or from one vault to another in the event of a flood.

Vll. CAUSE:

Upon investigation, it was discovered that the internal return springs had corroded and failed. The resulting lack of valve plate tension prevented the normally open valves from properly closing and seating.

The A01-4999-57, 58, and 60 valves are manufactured by the Fisher Controls Company and are 2 inch, model number 513RGS.

Vill. CORRECTIVE ACTION:

The corrective action taken was to replace the valve return springs inside drain valves A01-4999-57, 58, and 60. In addition, the other bed plate drain valves A0 1-h999-56 and 59, were inspected and the return springs also replaced as preventive maintenance. The bed plate drain valves were satisfactory retested on February 14, 1979