,,,,_,

Exelon Generation 10CFR 50.55a January 16, 2019 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Peach Bottom Atomic Power Station (PBAPS) Unit 2 Renewed Facility Operating License No.

DPR-44 NRC Docket No. 50-277

Subject:

Submittal of the lnService Inspection (ISi) Owner's Activity Report (OAR) for the 22nd Refueling Outage for Unit 2 Attached is the ISi Owner's Activity Report covering ISi activities associated with the third period of the 4th ISi inspection interval for Unit 2. This report is submitted pursuant to the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, "Rules for the lnservice Inspection of Nuclear Power Plant Components," Article IWA-6200, "Requirements" (2001 Edition through 2003 Addenda) and ASME Code Case N-532-5 (Repair/Replacement Activity Documentation Requirements and lnservice Inspection Summary Report Preparation and Submission,Section XI, Division 1).

If you have any questions or require additional information, please contact Bryce Sessions at 717-456-3863.

Sincerely,

~7h___

Matthew J. Herr Plant Manager Peach Bottom Atomic Power Station Attachment cc: US NRC, Regional Administrator, Region 1 US NRC, PBAPS Senior Resident Inspector R. R. Janati, Commonwealth of Pennsylvania D. Tancabel, State of Maryland B. Watkins, PSEG, Financial Control and Co-owner Affairs CCN: 19-14

FORM OAR*l OWNER'S ACTlVITY REPORT Plant Peach Bottom Atomic Power Station, 1848 Lay Road, Delta, PA 17314 Unit No. _ _ _2_____ Commercial Seivlce Date ----=J..;;;u.;..r.ly-=5;.L,..;;;;1..:;..97:....4.;..____ Refueling Outage Number ----=2:.:2_ __

(It applicable) current Inspection Inteival ISI =Fourth Inspection Interval I OSI =Second Inspection Interval 111, (tst, 2nd, 3rc1, 4 other)

Current Inspection Period ISI =Third Inspection Period / OSI =Third Inspection Period (1st, 2nd, Jrd )

Edition and Addenda of Section XI applicable to the Inspection Plans ASME Section XI 2001 Ed. through 2003 Add.

Date and Revision of Inspection Plans ISI Program Plan (PBT05.G03), Rev. 4 (9/2/2014 ), ER-PB-330-1001, Rev. 0 (9/18/2018)

Edition and Addenda of Section XI applicable to repair/replacement activities, If different than the Inspection plans Same as above Code cases used: N-432-1, N-460, N-504-4, N-508-4, N-513*3, N-513-4, N-516*3, N-517-1, N-526, N-528-1, N-532-5, N-552, N-552-1, N-561-2, N-562*2, N-566-2, N-578*1, N-586*1, N-597-2, N-600, N-606*1, N-613*1, N-613*2, N-624, N-629, N-638-4, N-638-6, N-639, N-641, N-648*1, N-651, N-652*1, N-652*2, N-653-1, N-661*2, N-666, N-666*1, N-685, N-686-1, N-695, N-696, N*

700, N-702, N-705, N-730, N-730*1, N-733, N-735, N-747, N-751, N-753, N-762, N-765, N-769, N-769*2, N-773, N-786*1, N-789, N-798, N-800, N-803, N-805, N-823, N-845 CERTIFICATE OF CONFORMANCE I certify that (a) the statements made In this report are correct; (b) the examinations and tests, meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of P2R22 conform to the requirements of Section XI

~~ (

(:s:J or own gnee.

Program Owner W-e)

Sl.H*)a" (refUellng outage number)

CERTIFICATE OF INSERVICE INSPEcnON I, the undersigned, holding a valid commission Issued by the National Soard of Boller and Pressure Vessel Inspectors and employed by The Hartford Steam Boller Inspection and Insurance Company of Hartford, Connecticut have Inspected the Items described In this owner's Activity Report, and state that, to the best of my knowledge and belief, the owner has performed all activities represented by this report In accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied concerning the repair/replacement activities and evaluation described In this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner ~ any personal In *ury or p erty damage or a loss of any kind arising from or connected with this Inspection.

~~Ul!':!....L.~~:!!:'!~~.==::=_ _ _ Commissions nspector's Signature) (National Board Number and Endorsement)

Date 1l/s:ho19

TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Examination Item hem Description Evaluation Description Cateaorv Number N/A N/A N/A N/A

I TABLE2 ABSTRACT OF ASME REPAIRS/REPLACEMENTS ACTIVITIES REQUIRED FOR CONTINUED SERVICE FOR PEACH BOTTOM ATOMIC POWER STATION, UNIT NO. 2 11/11/16 TO 10fJOl18

( END OF 2R22 REFUEL OUTAGE)

SYSTEMD1: Main Steam (MS) Flaw or Relevant Repair, Condition Found Replacement, DurinQ Scheduled Code or Corrective Item Description Section XI Exam Date Class Measure lcomnnnent 1.0.\ Descriotion Of Work Performed Or Test Comolete RlliR Plan #and W/O #

1 Replacement A0-2-01 A-0808 ReOlacement of 1 stud and 2 nuts on A0-2-01A-080B No 10/2612018 18-021, 04329928 1 Replacement A0-2-01A-080C Replacement of 5 stud and 5 nuts on A0-2-01A-080C No 10/26/2018 18-022, 04329928 2 Reolacement MS 4* Line Cut and Cao 4* MS Line Upstream of M0-2469 No 10/25/2018 , 8-039, 04746115

-

  • I SYSTEMB: Off-Oas/Steam Jet Air Ejector Flaw or Relevant Repair,  ! Condition Found Replacement, During Scheduled Code or Corrective Item Description Section XI Exam Date Class Measure fcomnonent I.DJ Descrintion Of Work Performed Or Test Comnlete RlliR Plan #and W/O #

1 2 Replacement HV-2-0BA-43001 A Install new MS lsol Viv for SJAE Train A No Not Comoleted 18-045, 04762849

1. AU associated work was not completed. IA #04211066 will track this work until completion and this ~ r wiU be included in the next OAR-1 cvcle.

SYSTEM 65A: HYDRAULIC SNUBBERS Aaw or Relevant Repair ,

Replacement, - Condition Found During Scheduled Code or Corrective Item Descriptl~n Section XI Exam Date Class Measure lcom...,..nent 1.0 .\ Descrintion Of Work Performed o r-Test Comolete RlliR Plan # and W/O #

1 Replacement SS-D-7 Replace hydraulic snubber SS-0-7 No 10/21/2018 18-082, 04765881 SYsTEllf SsB: MECHANICAL SNUBBERS

-- - Flaw or Relevant Repair, Condition Found Replacement, During Scheduled Code or Corrective Item Description Section XI Exam Date Class Measure lcomnnnent I.DJ Descriotion Of Work Performed Or Test Comolete R&R Plan #and W/O #

1 Replacement M-295-49-H2 Reolace mechanical snubber M-295-49-H2 No 10/2412018 18-046, 04761843 2 Replacement 10-GB-S-75 Replace mechanical snubber 10-GB-S-75 No 10/1512018 16-048, 04762876 2 Replacement 1Q-GB-S-92 Replace mechanical snubber 10-GB-S-92 No 10/15/2018 18-053, 04763267 i

I I

  • ----**-*---*-** ---=-i -

I I