MONTHYEARML24029A1132024-01-16016 January 2024 Notification of Inspection and Request for Information (Email) ML23207A0762023-07-14014 July 2023 EN 56557 - Update to Part 21 Report Re Potential Defect with Trane External Auto/Stop Emergency Stop Relay Card Pn: XI2650728-06 ML23192A0552023-07-11011 July 2023 Relief Request Later Edition of ASME Code for ISI ML23172A0132023-06-20020 June 2023 Duke Fleet - Correction to June 2, 2023, Request for Additional Information Proposed License Amendment Request to Revise Restrictive Surveillance Requirement Frequencies ML23159A0052023-06-0505 June 2023 56557-EN 56557 - Paragon - Redlined ML23153A1892023-06-0202 June 2023 Duke Fleet - Request for Additional Information Proposed License Amendment Request to Revise Restrictive Surveillance Requirement Frequencies ML23151A3482023-05-30030 May 2023 Duke Fleet - Request for Additional Information Proposed Alternative for Pressurizer Welds in Accordance with 10 CFR 50.55a(z)(1) ML23142A2732023-05-22022 May 2023 Duke Fleet - Request for Additional Information Proposed Alternative for Steam Generator Welds in Accordance with 10 CFR 50.55a(z)(1) ML23124A1212023-05-0404 May 2023 Acceptance of Requested Licensing Action Duke Fleet Proposed Alternative for Pressurizer Welds in Accordance with 10 CFR 50.55a(z)(1) ML23087A0282023-03-27027 March 2023 Acceptance of Requested Licensing Action Amendment TSTF-505 ML23087A2492023-03-27027 March 2023 50.69 Acceptance Email ML23073A2282023-03-13013 March 2023 Duke Fleet- Adoption of TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements - Acceptance Review ML23058A0562023-02-27027 February 2023 Acceptance of Amendment to Revise Surveillance Frequencies for RCS Pressure Isolation Valve Operational Leakage Testing and Reactor Trip System Instrumentation ML23048A1512023-02-16016 February 2023 Acceptance Review - Proposed Alternative for Steam Generator Welds (L-2023-LLR-0003) ML23030B9032023-01-30030 January 2023 Formal Release of RAIs for McGuire Unit 1, Relief Request Impractical RPV Rx Coolant System Welds, Due March 1, 2023 (Email) ML23017A2232023-01-13013 January 2023 Request for Additional Information (RAI) Issuance for McGuire Unit 1 Steam Generator Tube Inspection Report (Email) ML22291A4602022-10-17017 October 2022 Relief Request Impractical RPV and Rx Coolant Sys. Welds ML22242A1602022-08-30030 August 2022 Hardship Relief Request Pilot-Operated Relief Valve Acceptance Review Results ML22115A1412022-04-25025 April 2022 NRR E-mail Capture - Duke Common EOF Relocation - Request for Addition Information ML22083A0702022-03-24024 March 2022 NRR E-mail Capture - Catawba Nuclear Station, Units 1 and 2, Shearon Harris Nuclear Power Plant, Unit 1, and McGuire Nuclear Station, Units 1 and 2 - Acceptance Review for TSTF-569 LAR ML22049B0152022-02-17017 February 2022 NRC RP Inspection Document Request Letter ML22038A1572022-02-0707 February 2022 NRR E-mail Capture - Duke Energy Fleet - Acceptance of License Amendment Request Regarding Adoption of TSTF-541, Revision 2 ML22024A3952022-01-24024 January 2022 Acceptance of Requested Licensing Action Amendment McGuire RCS PT Limits Change TS 3.4.3 and EFPY Changes ML22018A0272022-01-18018 January 2022 2022 All RFI Responses - Exercise and Program Inspections - Revl ML21361A0122021-12-23023 December 2021 NRR E-mail Capture - Accepted for Review - Duke Energy Fleet License Amendment Request to Relocate Emergency Operations Facility ML21354A8612021-12-15015 December 2021 NRR E-mail Capture - Request for Additional Information - Duke Fleet Request RA-19-0352 - Alternative for RPV Closure Stud Exams (L-2020-LLR-0156) ML21286A7812021-11-22022 November 2021 Acceptance of Requested Licensing Action Revision to the End of Cycle Moderator Temperature Coefficient Measurement Methodology ML21295A0372021-10-0505 October 2021 NRR E-mail Capture - Accepted for Review - Duke Energy Fleet License Amendment Request to Adopt TSTF-577 Revised Frequencies for Steam Generator Tube Inspections ML21252A0532021-09-0808 September 2021 NRR E-mail Capture - Formal Release of Rais, 30 Day Response, Mcguire Relief Request, Ref: Later Edition Addenda ASME Code, Section XI, 50.55a(g)(4)(iv) ML21195A2022021-07-14014 July 2021 NRR E-mail Capture - McGuire Relief Request Acceptance Review Results; McGuire Unit 1 RR, Later Edition Addenda ASME Code, Section XI, 50.55a(g)(4)(iv) ML21103A0542021-04-13013 April 2021 NRR E-mail Capture - Extension to Request for Additional Information AMS Topical Report AMS-TR-0720R1 ML21096A3002021-04-0606 April 2021 E-mail for Approval of Proprietary Withholding for Duke Energy Exemptions for the Magnastor Storage Cask ML21096A2512021-04-0505 April 2021 NRR E-mail Capture - McGuire Emergency Plan Submittal, Letter Dated March 31 2021 ML21067A6742021-03-0505 March 2021 NRR E-mail Capture - Final Request for Additional Information AMS Topical Report AMS-TR-0720R1 ML21049A2632021-02-0404 February 2021 NRR E-mail Capture - Request for Additional Information - Duke Energy Fleet License Amendment Request to Revise Emergency Plan ML21007A3722021-01-0707 January 2021 NRR E-mail Capture - Acceptance Review - Duke Fleet - RA-19-0352 - Proposed Alternative for Reactor Vessel Close Stud Examinations (L-2020-LLR-0156) ML21006A4302021-01-0606 January 2021 Acceptance Review - Duke Fleet RA-20-0207 Request to Revise the Technical Specification for Engineered Safety Feature Actuation System (ESFAS) Instrumentation ML20346A0212020-12-10010 December 2020 NRR E-mail Capture - Formal Release of RAIs - License Amendment to Change TS 3.8.1 Due Jan. 29, 2021 ML20323A4072020-11-18018 November 2020 NRR E-mail Capture - Request for Additional Information - Brunswick License Exemption Request from 10CFR73 Annual Force on Force Exercise Requirements (EPIC L-2020-LLE-0180) ML20297A3102020-10-13013 October 2020 NRR E-mail Capture - Acceptance Review - Duke Fleet - RA-20-0191 - Request to Use a Provision of a Later Edition of the ASME B&PV Code, Section XI - IWA-5120, IWA-5213, IWA-5241, IWA-5242, and IWA-5250 (L-2020-LLR-0126) ML20297A3082020-10-0707 October 2020 NRR E-mail Capture - Acceptance Review - Duke Fleet - RA-20-0263 - Request to Use a Provision of a Later Edition of the ASME B&PV Code, Section XI for Repair/Replacement (L-2020-LLR-0124) ML20297A3092020-10-0606 October 2020 NRR E-mail Capture - Acceptance Review - Duke Fleet - RA-20-0262 - Request to Use a Provision of a Later Edition of the ASME B&PV Code, Section XI - IWA-4540(b) (L-2020-LLR-0125) ML20216A3512020-08-0303 August 2020 Mcquire U-1 ISI RFI ML20177A3792020-06-23023 June 2020 Email from L. Cox, North Carolina Department of Health and Human Services to NRC Regarding Exemption Request for Duke Energy'S McGuire Nuclear Station ML20140A0852020-05-19019 May 2020 ADAMS 2D ML20101L3132020-04-10010 April 2020 Notification of Inspection and Request for Information ML20071D0962020-03-0505 March 2020 NRR E-mail Capture - Request for Additional Information - McGuire Nuclear Station Unit 1 Delay in Update of the Code of Record for in Service Inspections ML20029E8592020-01-24024 January 2020 NRR E-mail Capture - McGuire Nuclear Station, Unit 1 -Acceptance of Requested Licensing Action Request to the 10-year ISI Interval Update ML20015A3162020-01-14014 January 2020 1/7/2020, E-Mail from M. Coflin to DCR Approval of Exemption Request McGuire Nuclear Facility ML20008D5592020-01-0707 January 2020 Email to Nc Shpo Exemption Request McGuire Nuclear Facility 2024-01-16
[Table view] Category:Inspection Plan
MONTHYEARML24029A1142024-01-29029 January 2024 Notification of Inspection and Request for Information ML24019A2002024-01-24024 January 2024 Notification of Inspection and Request for Information for NRC Problem Identification and Resolution Inspection IR 05000369/20240102023-10-13013 October 2023 Notification of McGuire Nuclear Station Comprehensive Engineering Team Inspection U.S. Nuclear Regulatory Commission Inspection Report 05000369, 370/2024010 IR 05000369/20230052023-08-25025 August 2023 Updated Inspection Plan for McGuire Nuclear Station Units 1 and 2 (Report 05000369/2023005 and 05000370/2023005) IR 05000369/20220062023-03-0101 March 2023 Annual Assessment Letter for McGuire Nuclear Station Units 1 and 2 (NRC Inspection Report 05000369/2022006 and 05000370 2022006) ML22347A1512022-12-13013 December 2022 William B. Mcguire Nuclear Station Notification of Licensed Operator Initial Examination 05000369/2023301 and 05000370/2023301 IR 05000369/20220052022-08-29029 August 2022 Updated Inspection Plan for McGuire Nuclear Station Units 1 and 2 NRC Inspection Report 05000369/2022005 and 05000370/2022005 ML22094A0952022-04-0606 April 2022 Requalification Program Inspection - McGuire Nuclear Station IR 05000369/20210062022-03-0202 March 2022 Annual Assessment Letter for McGuire Nuclear Station, Units 1 and 2 (Report 05000369/2021006 and 05000370/2021006) ML22018A0292022-01-18018 January 2022 Region 2 RFI - 2022 Program Inspections ML22010A0732022-01-0606 January 2022 50.59 Inspection Information Request ML21267A2782021-09-23023 September 2021 50.59 Inspection Information Request IR 05000369/20210052021-08-23023 August 2021 Updated Inspection Plan for McGuire Nuclear Station, Units 1 and 2 (NRC Inspection Report 05000369/2021005 and 05000370/2021005) IR 05000369/20200062021-03-0303 March 2021 Annual Assessment Letter for McGuire Nuclear Station, Units 1 and 2 - NRC Inspection Report 05000369/2020006 and 05000370/2020006 ML21020A0682021-01-20020 January 2021 Notification of an NRC Fire Protection Team Inspection (FPTI) (NRC Inspection Report 05000369/2021011 and 05000370/2021011) and Request for Information (RFI) ML20280A6722020-10-0606 October 2020 Notfication of McGuire Nuclear Station Design Bases Assurance Inspection - U.S. Nuclear Regulatory Commission Inspection Report 05000369/2021010 and 05000370/2021010 IR 05000369/20200052020-08-17017 August 2020 Updated Inspection Plan for Mcguire Nuclear Station Units 1 and 2 (NRC Inspection Report 05000369/2020005 and 05000370/2020005) IR 05000369/20190062020-03-0303 March 2020 Annual Assessment Letter for McGuire Nuclear Station Units 1 and 2 - NRC Inspection Report 05000369/2019006 and 05000370/2019006 IR 05000369/20190052019-08-26026 August 2019 Updated Inspection Plan for McGuire Nuclear Station, Units 1 and 2 (NRC Inspection Report 05000369/2019005 and 05000370/2019005) IR 05000369/20180062019-03-0404 March 2019 Annual Assessment Letter for McGuire Nuclear Station, Units 1 and 2 - NRC Inspection Report 05000369/2018006 and 05000370/2018006 ML18333A0912018-11-29029 November 2018 Op Ess 201801 RFI - SD IR 05000369/20180052018-08-20020 August 2018 Updated Inspection Plan for McGuire Nuclear Station Units 1 and 2 -NRC Inspection Report 05000369/2018005 and 05000370/2018005 ML18074A0162018-03-15015 March 2018 Emailed Hs 2018002 Hs ML18059A0932018-02-28028 February 2018 EOC Assessment Letter IR 05000369/20170052017-08-16016 August 2017 Updated Inspection Plan for McGuire Nuclear Station, Units 1 and 2 - NRC Inspection Report 05000369/2017005 and 05000370/2017005 ML17114A4992017-04-17017 April 2017 Emergency Preparedness Inspection and Request for Information IR 05000369/20160062017-03-0101 March 2017 Annual Assessment Letter for McGuire Nuclear Station, Units 1 & 2 -NRC Inspection Report 05000369/2016006 and 05000370/2016006 ML17024A2812017-01-23023 January 2017 William B. McGuire Nuclear Plant - Notification of Inspection and Request for Information IR 05000369/20160052016-08-31031 August 2016 Mid-Cycle Assessment Letter for McGuire Nuclear Station Units 1 and 2 (NRC Inspection Report 05000369/2016005 and 05000370/2016005) ML16082A1362016-03-21021 March 2016 Requalification Program Inspection - McGuire Nuclear Station ML16062A2152016-03-0202 March 2016 Annual Assessment Letter ML16061A0252016-02-29029 February 2016 PIR Notification Letter 2016 ML16032A0922016-01-29029 January 2016 William B. McGuire Nuclear Station, Unit 1, Notification of Inspection and Request for Information ML16026A5912016-01-26026 January 2016 William B. McGuire - Notification of Inspection and Request for Information ML15251A2242015-09-0202 September 2015 Notification of Conduct of a Triennial Fire Protection Baseline Inspection - U. S. Nuclear Regulatory Commission Inspection Report 05000369/2015008 and 05000370/2015008 IR 05000369/20150052015-09-0101 September 2015 Mid-Cycle Assessment Letter for McGuire Nuclear Station Units 1 and 2 (NRC Inspection Report 05000369/2015005 and 05000370/2015005) IR 05000369/20140012015-03-0404 March 2015 Annual Assessment Letter for McGuire Nuclear Station Units 1 and 2 (NRC Inspection Report 05000369/2014001 and 05000370/2014001) ML14351A0182014-12-12012 December 2014 IR 05000369/2015007 and 05000370/2015007, Notification of McGuire, Units 1 and 2, Component Design Bases Inspection ML14245A1322014-09-0202 September 2014 Mid-Cycle 2014 Letter ML14063A1572014-03-0404 March 2014 2013 Annual Assessment Letter for McGuire Nuclear Station, Units 1 and 2 ML13246A1622013-09-0303 September 2013 Mid Cycle Assessment Letter IR 05000369/20120012013-03-0404 March 2013 Annual Assessment Letter for McGuire, Units 1 & 2, (IR 05000369-12-001 and 05000370-12-001) ML12248A0592012-09-0404 September 2012 Mid Cycle Assessment Letter McGuire 2012 ML12066A0272012-03-0505 March 2012 Report 22, Inspection Activity Plan ML11364A0192011-12-12012 December 2011 Fourth Inservice Inspection Interval Plan ML1124403202011-09-0101 September 2011 Report 22, Inspection/Activity Plan, 09/01/2011- 12/31/2012 ML1106301172011-03-0404 March 2011 Inspection / Activity Plan, Report 22, 03/01/2011 - 06/30/2012 ML1024407572010-09-0101 September 2010 Report 22, Inspection/Activity Plan ML1006200602010-03-0303 March 2010 Enclosure 2 - Inspection/Activity Plan Report 22 ISFSI ML1006208642010-03-0303 March 2010 Enclosure 1 - Inspection/Activity Plan, Report 22 2024-01-29
[Table view] |
Text
ML18333A091 MCGUIRE NUCLEAR STATION, UNIT 2 - NOTIFICATION OF INSPECTION AND REQUEST FOR INFORMATION Joseph Hussey:
During the week of January 21 - January 25, 2019, the Nuclear Regulatory Commission (NRC) will perform an inspection of McGuire Nuclear Station, Unit 2, in accordance with Operating Experience Smart Sample 2018/01, Evaluation of Licensee Actions Taken in Response to 10CFR Part 21 Notification of Potential Existence of Defects Related to Control Rod Drive Mechanism (CRDM) Thermal Sleeves (ML18263A261). The NRC requests that the information requested in Section A and B be provided to the lead inspector no later than January 14, 2018.
If there are any questions about this inspection, or the material requested, please contact the lead inspector, Steven Downey, at (404) 997-4830 or Steven.Downey@nrc.gov or the Engineering Branch 3 Chief, Brian Bonser at (404) 997-4653.
In accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding, a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRC's Agencywide Document Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
PAPERWORK REDUCTION ACT STATEMENT This letter does not contain new or amended information collection requirements subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection requirements were approved by the Office of Management and Budget, control number 3150-0011.
PUBLIC PROTECTION NOTIFICATION The NRC may not conduct or sponsor, and a person is not required to respond to, a request for information or an information collection requirement unless the requesting document displays a currently valid Office of Management and Budget control number.
Inspection Procedure: 71152, Problem Identification and Resolution Sample: Operating Experience Smart Sample (OPESS) 2018/01, Evaluation of Licensee Actions Taken in Response to 10 CFR Part 21 Notification of the Potential Existence of Defects Related to Control Rod Drive Mechanism (CRDM) Thermal Sleeves Inspection Dates: January 21-25, 2019 Inspector: Steven Downey, Sr. Reactor Inspector The inspector will need the information requested (as indicated below) prior to the inspection.
Please provide the requested information by January 14, 2018. If possible, provide the requested information electronically (i.e., Certrec, FTP, DVD/CD, web).
A. Unit(s) for which the recommended actions described in NSAL 18-1 have been completed
- 1. Provide the date or Refueling Outage during which the flange wear measurements were taken.
- 2. Briefly describe the method used to perform the thermal sleeve measurement.
- 3. Was as-built information used for the reference point in determining the thermal sleeve lowering values?
- 4. For each unit, provide the following information for each CRDM location*:
- i. CRDM Location Identifier ii. Acceptance criteria iii. As built measurement (or as designed measurement) (if available) iv. As-found wear
- v. Wear rate vi. Re-inspection frequency vii. Acceptance criteria exceeded? (Yes/No) viii. If acceptance criteria exceeded, has flange separation occurred? (Yes/No)
- 5. Provide a copy of the document used to determine the acceptance criteria.
- 6. For each location that wear measurements were above the acceptance criteria, but flange separation has not occurred, briefly describe what actions were taken.
- 7. For each location where flange separation has occurred, briefly describe what actions were taken to mitigate the issue and provide any associated documents and procedures.
- Note that, as stated in OPESS 2018/01, the inspector will provide this information to the program office. Please mark the submittal documents appropriately (proprietary vs non-proprietary)
From: Downey, Steven To: Hussey, Joseph Foster; Kandell, Brian Michael
Subject:
Request for Information for Operating Experience Smart Sample 2018/01 Inspection Date: Thursday, November 29, 2018 8:25:10 AM Attachments: MCG U2 OpESS201801 RFI - SD.pdf Mr. Hussey, Attached is the Information Request for the baseline PI&R sample (OpESS 2018/01) inspection for McGuire Unit 2 scheduled for the week of January 21-25, 2019.
Please let me know that you received this request. If there are any questions about this inspection or the material requested, please contact me via email, or at the phone number or address included below.
- Regards, Steve Steven Downey II, Ph.D.
Sr. Reactor Inspector Region II - Engineering Branch 3 US Nuclear Regulatory Commission 245 Peachtree Center Ave. NE, Suite 1200 Atlanta, GA 30303 (404.997.4830 *steven.downey@nrc.gov "Success is no accident. It is hard work, perseverance, learning, studying, sacrifice, and most of all, love of what you are doing or learning to do.