Licensee Handouts (1 of 2) for 4/22/2015 Public Meeting Revised Roverd Section on Large Early Release Frequency Change for Large Break Loss-of-Coolant Accident(Tac Nos. MF2400-MF2409)
ML15111A056
Person / Time
Site: South Texas  
Issue date: 04/15/2015
From: Harrison A
South Texas
To:
Plant Licensing Branch IV
Regner L
References
TAC MF2400, TAC MF2401, TAC MF2402, TAC MF2403, TAC MF2404, TAC MF2405, TAC MF2406, TAC MF2407, TAC MF2408, TAC MF2409
Download: ML15111A056 (2)


Text

STPNOC RoverD: Risk over Deterministic GSI-191 Assessment 116 pages wj =

fj q

j fj

j = 1, 2, (5.8a) j =wj NP

ÿ n=1 I

ÿ iœRn F(Dsmall i

),

(5.8b)

=

ÿ j

j.

(5.8c) 5.5 LERF frequency Because the STP RCFC are independent of the concerns raised in GSI-191, and because their design can remove decay and maintain contamination RCB limits within design, concerns raised in GSI-191 would not result in containment failure. The RCFC design allows for simpli"cation of LERF. That is, for the STP design, the change in early release frequency could be assumed directly proportional to the change in core damage frequency:

LERF = LERFMOR 3 CDF CDFMOR 4

(5.9)

Because all the scenarios in the risk-informed category are LLOCA, only the LLOCA frequency for LERF from the STP PRA model of record contributes to LERF in RoverD.

The LLOCA LERF for the arithmetic mean quanti"cation is 1.73E-10yr1. The geometric mean for LLOCA LERF is 3.1E-11yr1.

5.6 Results STP has two Cases (Case 1 and Case 2) other than the condition tested (AREVA, 2008) that are bounding for "ne "ber amounts. The tested deterministic case assumed two of the three STP ECCS strainers in operation (single failure criterion). Case 1 is the most likely case when all three strainers are in operation. In this case, far less "ber will accumulate on each strainer than for the tested case. Therefore, Case 1 is bounded by the tested case.

However, Case 2 corresponds to a case where only one train of the three STP ECCS strainers are in operation. Although this case is beyond design basis, it needs to be consid-ered in the risk analysis since at least twice as much "ber would accumulate on the single strainer than when two or more strainers are in operation. In this case, only 1/2 the tested amount of "ne "ber can be assumed to be tolerated.

Wednesday 15th April, 2015, 08:55 29 corresponding: keeej@stpegs.com

STPNOC RoverD: Risk over Deterministic GSI-191 Assessment 116 pages Table 5.2: Case 1 and Case 2 results for geometric (GM) and arithmetic (AM) aggregations of Tregoning et al. (2008, Tables 7.11 and 7.19) data. Frequencies are in events/yr. Also shown are the results for a DEGB-only model for the locations that go to failure.

Continuum Break Model Quantile Case 1 GM Case 1 AM Case 2 GM Case 2 AM (GM)

(AM) 5th 2.64E-10 6.47E-09 3.68E-09 2.36E-08 3.08E-10 6.69E-09 50th 7.50E-09 1.68E-07 8.30E-08 4.92E-07 8.47E-09 1.72E-07 95th 3.43E-07 4.79E-06 1.81E-06 1.24E-05 3.62E-07 4.89E-06 Mean 1.17E-07 1.56E-06 5.10E-07 3.93E-06 1.22E-07 1.59E-06 DEGB-Only Model 5th 9.83E-11 8.18E-09 1.14E-09 1.66E-08 1.12E-10 8.29E-09 50th 2.86E-09 2.07E-07 2.64E-08 3.90E-07 3.16E-09 2.09E-07 95th 1.47E-07 7.06E-06 6.85E-07 1.21E-05 1.54E-07 7.13E-06 Mean 5.12E-08 2.06E-06 2.03E-07 3.61E-06 5.32E-08 2.08E-06 Table 5.3: LERF evaluation for geometric and arithmetic means of the Continuum and DEG-only models.

Model LERF using (GM)

LERF using (AM)

Contiuum break model 4.11E-13 2.99E-11 DEGB-only model 1.79E-13 3.91E-11 5.7 CDF results When all cases are considered using (5.8), a slightly higher CDF is estimated than when only one strainer is in operation. Table 5.2 summarizes the CDF estimate for geometric and arithmetic averages from Tregoning et al. (2008). The frequencies for the bounding cases are f2 = 3.32E 6yr1 (Case 1) and f1 = 4.34E 8yr1 (Case 2). As shown, the median CDF is within Region III of the Regulatory Guide 1.174 evaluation ( 1.0E06).

Interpolation of Table 5.1 is done using the linear-linear method, (5.2).

As shown in Table 5.2, only the mean and 95th percentile of the arithmetic mean estimate exceed the Region III criterion in (NRC, 2011). As described in the letter to the NRC dated May 22, 2014 (ML14149A434), the geometric method of aggregation is the most appropriate estimator of LOCA frequency from (Tregoning et al., 2008).

5.8 LERF results Using (5.9), LERF values were calculated using CDF for geometric and arithmetic means using baseline CDF. LERF values for geometric and arithmetic quanti"cations for LLOCA were used for the baseline LERF values. The results are summarized in Table 5.3.

Wednesday 15th April, 2015, 08:55 30 corresponding: keeej@stpegs.com