ALION-REP-STP-8998-02, Rev. 0, STP Casa Grande Analysis and LAR Enclosure 4-3 RAI Response, Enclosure 1 to Attachment 1
ML14149A435
Person / Time
Site: South Texas  
Issue date: 02/14/2014
From: Munoz D
ALION Science & Technology Corp
To:
Office of Nuclear Reactor Regulation
Shared Package
ML14149A439 List:
References
GSI-191, NOC-AE-14003103, ST133840343, TAC MF2400, TAC MF2401 ALION-REP-STP-8998-02, Rev. 0
Download: ML14149A435 (6)


Text

NOC-AE-1 4003103 to Attachment 1 Alion report supporting resolution of APLAB, CASA Grande - LOCA Frequencies: RAI 4 (ALION-REP-STP-8998-02, Rev. 0, "STP CASA Grande Analysis and LAR Enclosure 4-3 RAI Response")

NOC-AE-1 4003103 Page 1 of 5 SCLION SCIENCE AND TECHNOLOGY TECHNICAL DOCUMENT COVER PAGE Document No: ALION-REP-STP-8998-02 Revision:0 Page 1

of 5

Document

Title:

STP CASA Grande Analysis and LAR Enclosure 4-3 RAI 1Response Project No: STP-8898 Project Name: STP Risk Informed GSI-191 Support Client: STP Nuclear Operating Company Document Purpose/Summary: Request for additional information 1 (RAI 1) inquired about reference specific, pertinent weld break frequency information that was used in the STP CASA Grande analysis documentation (LAR Enclosure 4-3).

This document cross references LAR Enclosure 4-3 with references of interest and their contents, and provides high-level clarification of their usage.

This document is not considered safety related. However, it has been prepared, reviewed, and approved.

Design Verification Method:

X Design Review Alternative Calculation

___ Qualification Testing Professional Engineer (if required)

Approval:

N/A Date N/A Dominic Muhioz/ Ernie Kee*

2/14/2014 Prepared By:

Printed/Typed Name Signature Date Bruce Letellier 2/14/2014 Reviewed By:

Printed/Typed Name Signature Date Megan Stachowiak 2/14/2014 Approved By:

Printed/Typed Name Signature Date

NOC-AE-1 4003103 Page 2 of 5 ALION-REP-STP-8998-02 Revision:

0 STP CASA Grande Analvsis and LAR F~nclrv~iir* 4-3 RAI I Rosnrv-n*

Document Number:

Document

Title:

STP CASA Grande Analvsis and LAR Enclosure 4-3 RAI I Resrionse REVISION DATE Description 0

See Cover Initial release.

Page

  • Denotes a preparer from outside of the ALION organization. All technical information provided and its correctness are solely the responsibilities of internal staff.

NOC-AE-1 4003103 Page 3 of 5 Table of Contents Table of Contents.......................................................................................................................

3 RA I #1 PRA Licensing Branch (A PLA).............................................................................

4 R e sp o n se.......................................................................................................................................

4 Availability of Reference 8 for Review...........................................................................

4 Confirm ation of References.............................................................................................

4 Specific Aspects of References used in the LA R.........................................................

5 Cross Reference Sum m ary...........................................................................................

5 Clarification Details......................................................................................................

5

NOC-AE-1 4003103 Page 4 of 5 RAI #1 PRA Licensing Branch (APLA)

Volume 3 of the license amendment request (LAR) describes the process used to assign break frequencies to welds in containment and cites two documents listed as references 7 & 8:

7. KNF Consulting Services LLC and Scandpower Risk Management Inc. Development of LOCA Initiating Event Frequencies for South Texas Project GSI-191 Final Reportfor 2011 Work Scope.

September 2011.

8. University of Texas at Austin. Modeling and Sampling LOCA Frequency and Break Size for STP GSI-191 Resolution. September 2012.

The staff notes that several versions of these documents are publically available in the NRC's Agency-wide Documents Access and Management System (ADAMS). A brief comparison of the fitted Johnson parameters in the above version of Reference 8 to Table 2.2.2 revealed differences between the LAR and the referenced document. Please confirm that Volume 3 contains the correct information from these reports and cites the correct versions of the aforementioned references. Please clarify exactly which aspects of the aforementioned references (e.g., by providing specific section or equation numbers) are used in the STP pilot application.

Response

Availability of Reference 8 for Review LAR Enclosure 4-3 Reference 8 has been sent for publication in the NRC PDR with STP transmittal letter NOC-AE-13003070 (Letter, dated December 23, 2013, M.D. Meier to the NRC Document Control Desk) in order to make it publically available for review.

Confirmation of References The two referenced documents number (7), and (8) in STP's GSI-191 submittal are shown below as listed in LAR Enclosure 4-3.

7.

KNF Consulting Services LLC and Scandpower Risk Management Inc. Development of LOCA Initiating Event Frequencies for South Texas Project GSI-191 Final Report for 2011 Work Scope. September 2011.

8.

University of Texas at Austin. Modeling and Sampling LOCA Frequency and Break Size for STP GSI-191 Resolution. September 2012.

The revision number and date of LAR Enclosure 4-3 Reference 7 as written has been confirmed to be correct.

The revision number and date of LAR Enclosure 4-3 Reference 8 as written has been confirmed to be correct.

NOC-AE-1 4003103.

Page 5 of 5 Specific Aspects of References used in the LAR Cross Reference Summary Table 1: LAR End 4-3 Cross Reference Matrix Cross Reference -3 (Table)CrsRernc LAR Encl. 4-3 Ref. No.

Ref. Section Ref. Page Ref. Table (37) 7.8 7-55 7.19 Table 2.2.2 (8) 5 44 31 (8) 2.1 7

(8) 5 44 32 Tables 2.2.3-2.2.10 (7) 5 5-1 to5-4 "2 Clarification Details Weld break frequencies are estimated in NUREG 1829 (Ref. 37 of LAR Encl. 4-3). The values from this elicitation are titled "NUREG-1829 Quantiles" in Table 2.2.2 of LAR Encl. 4-3, and are identical to the values given in Table 7.19 (Pg. 7-55) of NUREG-1829 for current-day break frequencies with the exception of two additional break sizes. These two additional break sizes (in LAR Encl. 4-3, Table 2.2.2) were linearly interpolated between NUREG-1829 frequencies to be consistent with the STP probabilistic risk assessment (PRA) SBLOCA and MBLOCA bounding break sizes of 2 inches (SBLOCA-MBLOCA) and 6 inches (MBLOCA-LBLOCA). Interpolation was performed for the 5 th percentile, median, mean, and 9 5 th quantiles of the NUREG-1829 distributions as described in Section 5 of Encl. 4-3 Reference 8, and the interpolated values are shown in Encl. 4-3 Reference 8, Table 31.

The quantiles of current-day break frequencies in NUREG-1829 Table 7.19 were fit to a parametric (Bounded Johnson) distribution as described in Section 2 of LAR Encl. 4-3 Reference 8. The Johnson parameters from Table 2.2.2 of LAR Encl. 4-3 are also described in LAR Encl. 4-3 Reference 8. As described, the parameters of the Johnson distributions closely fit the 5 th percentile, median, and 9 5th percentile of the NUREG-1829 distribution values (Section 2.1, Table 3 of LAR Encl. 4-3 Reference 8) with explicitly listed parameter values in LAR Encl. 4-3 Reference 8 Table 2. The parametric fit for a Johnson distribution at the two additional break sizes at the interpolated values of 2 and 6 inches (described above) are given in LAR Encl. 4-3 Reference 8 Table 32. Estimates of the mean break frequency reported in NUREG-1829 Table 7.19 were not used in this analysis.

Reference 7 Tables 5-1 through 5-4 are the source for the values in LAR Encl. 4-3 Tables 2.2.3-2.2.10. The values from tables 5-1 through 5-4 were used as weighting factors to distribute NUREG-1829 total break frequencies across weld types and to containment locations by matching weld types with containment weld data. In LAR Encl. 4-3, conservation of NUREG-1829 total break frequency is referred to as the "top-down" portion of the "hybrid" break frequency approach. Tables 5-1 through 5-4 from reference 7 represent the product of "bottom-up" aggregation of cross-industry data on observed flaws or degradation that may lead to breaks.