Description of Supplement 2 to STPNOC Risk-Informed Licensing Application to Address GSI-191 and Respond to GL-2004-02 Public Phone Call Meeting with NRC October 1, 2015 DRAFT

Introduction and Agenda

  • Introduction of STP participants
  • Desired Outcomes:
  • NRC staff understand the STPNOC licensing application and the changes from the previous supplement
  • Resolve NRC questions and establish follow-up to resolve questions that remain open
  • Identify steps remaining for going forward with the application 2

DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT

Introduction and Agenda

  • Agenda
  • Effect on reported results
  • Conservatism and acceptability of revised approach
  • Thermal-Hydraulic application to RoverD
  • Specific Focus Areas
  • Follow-up and Going Forward Actions 3

DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT

Overview of Changes from November 13, 2013 Letter

  • Changed methodology to explicitly incorporate certain deterministically-based elements Risk over Deterministic approach (RoverD) that was described in March 25, 2015 letter (ML15091A440)
  • Added the plant-specific testing deterministic basis (Letter Attachment 1-2)
  • Addressed all the NRC content guide questions and responded to earlier RAIs (Letter -5)
  • Added the RoverD risk-informed description (Letter Attachment 1-3)
  • Expanded Defense-in-Depth and Safety Margin discussion (Letter Attachment 1-4)
  • Clarification on exemptions
  • Changed exemption to 10CFR50.46 to be to other requirements (10CFR50.46(d))
  • Clarified that a specific exemption to single failure is not being requested
  • Added proposed Technical Specification change for debris-specific effects (Letter Attachment 3) 4 DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT

Overview of Changes from November 13, 2013 Letter

  • What is no longer in the scope of the application and should not be part of the review, including RAI responses:
  • CASA Grande calculation of conditional failure probabilities
  • Use of correlations for head loss, including bump-up factors
  • Uncertainty quantification of pipe break probability distributions; replaced with conservative estimates
  • Time dependent debris transport
  • Use of STP PRA for calculation of delta CDF; used only for delta LERF
  • Applications of CASA Grande that are still used
  • Debris generation
  • Debris arrival to the containment pool (non-time dependent) 5 DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT

Results with Revised Methodology Remain in RG 1.174 Region III

  • Conclusions are unchanged with revised methodology
  • 2015 RoverD:

CDF: 1.23E-07/yr, LERF: 3.08E-10/yr

  • 2013 CASA Grande/PRA:

CDF: 2.88E-08/yr, LERF: 1.40E-11/yr 6

DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT

Conservatism and Acceptability of Revised Approach 7

DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT

Conservatism and Acceptability of Revised Approach

  • Deterministically tested debris
  • Qualitative margin evaluation of July 2008 test determined that low density fiberglass is the only debris source term not bounded by the test
  • Marinite and Microtherm are treated as small fines
  • Use of fiber fines as representative debris based on test observations
  • Chemical effects are included that STP-specific testing and analysis show are bounding
  • Considers various break types and locations
  • Conservatisms used in transport calculation
  • Initial distribution
  • 100% transport of fiber fines
  • Operation of spray system
  • Recirculation assumptions 8

DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT

Thermal-Hydraulic Application to RoverD

  • Thermal-Hydraulic Analyses Show Long-Term Cooling PCT Less than 800°F
  • Analysis assuming total blockage of core and core bypass shows that there is sufficient cooling for all HLB and SLOCA
  • FA tests show that there is insignificant pressure drop for bounding HLB conditions (DEGB, no credit for decay heat at time of recirculation) with 15 gm/FA including chemical effects
  • STP strainer penetration testing shows that, for DEGB CLB, less than 3 gm/FA accumulates on the core 9

DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT

Specific Focus Items

  • Bounding debris transport fractions do not have direct spill paths to the containment floor
  • Transport evaluation included 1, 2, and 3 trains operating
  • Evaluation of transport of unqualified epoxy, particulate, and chips shows sufficient margin
  • Erosion Methodology
  • STP conditions are bounded by 30-day erosion testing showing factors below 10%
  • Methodology shown in Table 10 of Att. 1-2 of 8/20/15 letter
  • Early or late arrival is based on initial blow-down to pool or wash down by spray
  • Small and large percentage are the eroded fractions from small and large debris
  • Early and late arrival of fines based on initial blow-down to pool or wash down by spray
  • Margin evaluation of July 2008 test shows that low density fiberglass is the only debris source term not bounded by the test 10 DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT

Follow-up and Going Forward Actions

  • November public meeting to resolve outstanding questions 11 DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT