Nuclear Operating Company South Texs Pro/ect Electric Generating Station P.O Box 289 Wadsworth, Texas 77483 r

October 30, 2014 NOC-AE-14003190 10 CFR 50.12 10 CFR 50.90 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 South Texas Project Units 1 and 2 Docket Nos. STN 50-498 and STN 50-499 Strainer Test Plan in Support of STP Pilot Risk-Informed GSI-191 Pilot Licensing Application (TAC Nos. MF2400 and MF2401)

Reference:

Letter, G. T. Powell, STPNOC, to NRC Document Control Desk, "Supplement 1 to Revised STP Pilot Submittal and Requests for Exemptions and License Amendment for Risk-Informed Approach to Resolving Generic Safety Issue (GSI)-191" November 13, 2013 (NOC-AE-13003043, ML13323A183)

In the referenced correspondence, STP Nuclear Operating Company (STPNOC) submitted a pilot application for a risk-informed methodology for the resolution of GSI-191. The NRC staff has issued requests for additional information (RAI) regarding the application of the STPNOC methodology with respect to the correlations that were used and commented that there is insufficient test data to fully support the use of the correlations. To support response to the staff's RAI, STPNOC has developed the attached test plan. The attachments include an executive summary of the test plan and a detailed test plan.

The intent of the test plan is to provide additional support for the correlations in the STPNOC methodology and to provide additional data regarding behavior of debris prototypical to STP. STPNOC requests that the staff review the attached plan as a primary agenda item for a public conference call scheduled for November 6, 2014.

There are no regulatory commitments in this submittal.

STI 33969356

NOC-AE-14003190 Page 2 of 3 If there are any questions regarding this request, please contact Wayne Harrison at (361) 972-8774 or me at (361) 972-7566.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on:

O3-t' G. T. Powell Site Vice President Awh Attachments:

1. Strainer Test Plan in Support of STP Pilot Risk-Informed GSI-191 Pilot Licensing Application (Executive Summary)
2. Strainer Test Plan in Support of STP Pilot Risk-Informed GSI-191 Pilot Licensing Application
3.

Definitions and Acronyms

NOC-AE-14003190 Page 3 of 3 cc:

(paper copy)

(electronic copy)

Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Balwant K. Singal Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8 B1) 11555 Rockville Pike Rockville, MD 20852 NRC Resident Inspector U. S. Nuclear Regulatory Commission P.O. Box 289, Mail Code: MN116 Wadsworth, TX 77483 Steve Frantz Morgan, Lewis & Bockius LLP Balwant K. Singal Michael Markley John Stang U. S. Nuclear Regulatory Commission John Ragan Chris O'Hara Jim von Suskil NRG South Texas LP Kevin Polio Cris Eugster L. D. Blaylock CPS Energy Peter Nemeth Crain Caton & James, P.C.

C. Mele John Wester City of Austin Richard A. Ratliff Texas Department of State Health Services Robert Free Texas Department of State Health Services