Other: ML13212A367, ML14050A304, ML14071A620, ML14072A369, ML14092A346, ML14177A430, ML14238A691, ML14245A371, ML14300A218, ML14317A783, ML15027A196, ML15098A181, ML15106A736, RS-14-183, Updated Responses to NRC Set 14 Requests for Additional Information, Related License Renewal Application, RS-14-249, Results of Detailed Review Performed in Response to Request 1 of NRC RAI B.2.1.7-7 from Set 17, Related to License Renewal Application, RS-15-049, Units 1 and 2 - LRA Impact Assessment Associated with Earlier Responses to Set 29 RAI B.2.1 .5-1a, Related to the License Renewal Application, ULNRC-06118, Updated RAI Response to the License Renewal Application, Enclosures 1 and 2
|
MONTHYEARML13212A3672013-08-12012 August 2013 Plan for the Aging Management Program Regulatory Audits Regarding the Byron and Braidwood Nuclear Stations License Renewal Application Review Project stage: Other ML13262A0352013-10-0707 October 2013 Requests for Additional Information for the Review of the Byron Nuclear Station, Units 1 and 2, and Braidwood Nuclear Station, Units 1 and 2, License Renewal Application -Aging Management, Set 1 Project stage: RAI ML13281A5572013-10-28028 October 2013 Summary of Telephone Conference Call Held on September 25, 2013 Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning RAIs Pertaining to the Byron-Braidwood License Renewal Application (TAC Nos. MF187 Project stage: RAI ML13303B4632013-11-25025 November 2013 Summary of Telephone Conference Call Held on October 22, 2013, Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning RAI Set 3 for the Byron-Braidwood LRA Project stage: RAI ML13281A5742013-11-25025 November 2013 Requests for Additional Information for the Review of the Byron Nuclear Station, Units 1 and 2, and Braidwood Nuclear Station, Units 1 and 2, License Renewal Application - Aging Management, Set 3 (TAC Nos. MF1879, MF1880, MF1881, and MF1882 Project stage: RAI ML13281A5692013-12-12012 December 2013 Request for Additional Information for the Review of the Byron Nuclear Station Units 1 and 2, and the Braidwood Nuclear Station Units 1 and 2, LRA - Aging Management, Set 4 Project stage: RAI ML13282A3692013-12-13013 December 2013 Requests for Additional Information for the Review of the Byron Nuclear Station, Units 1 and 2, and Braidwood Nuclear Station, Units 1 and 2, License Renewal Application - Aging Management, Set 2 Project stage: RAI RS-13-273, Responses to NRC Requests for Additional Information, Set 3, Dated November 25, 2013, Related to the License Renewal Application2013-12-17017 December 2013 Responses to NRC Requests for Additional Information, Set 3, Dated November 25, 2013, Related to the License Renewal Application Project stage: Response to RAI RS-13-274, Response to NRC Requests for Additional Information, Set 5, Dated November 22, 2013, Related to License Renewal Application2013-12-19019 December 2013 Response to NRC Requests for Additional Information, Set 5, Dated November 22, 2013, Related to License Renewal Application Project stage: Response to RAI ML13317A0752014-01-13013 January 2014 Requests for Additional Information for Review of Byron, Units 1 & 2, and Braidwood, Units 1 & 2, License Renewal Applications, Set 6 Project stage: RAI RS-14-003, Bryon, Units 1 and 2, Response to NRC Requests for Additional Information, Set 2, Dated December 13, 2013, Related to the License Renewal Application2014-01-13013 January 2014 Bryon, Units 1 and 2, Response to NRC Requests for Additional Information, Set 2, Dated December 13, 2013, Related to the License Renewal Application Project stage: Response to RAI ML14017A0072014-01-16016 January 2014 Enclosure 1 to ULNRC-06072, Callaway Plant, Unit 1, Responses to Request for Additional Information (RAI) Sets 29 and 27 (RAI B2.1.6-4b) Project stage: Response to RAI ML14007A6582014-01-22022 January 2014 Requests for Additional Information for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application, Set 9 Project stage: RAI ML13309A9322014-01-23023 January 2014 Summary of Telephone Conference Call Held on October 31, 2013, Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Draft Requests for Additional Information Pertaining to the Byron Station and Braid Project stage: Draft RAI ML13330A9322014-01-23023 January 2014 Bbs Record of Conference Call-Regarding-RAI Set 4 110513 Project stage: RAI ML13318A4152014-01-23023 January 2014 November 12, 2013, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Draft Requests for Additional Information Pertaining to the Byron Station and Braidwo Project stage: Draft RAI RS-14-030, Response to NRC Requests for Additional Information, Set 6, Dated January 13, 2014, Related to License Renewal Application2014-02-0404 February 2014 Response to NRC Requests for Additional Information, Set 6, Dated January 13, 2014, Related to License Renewal Application Project stage: Response to RAI ML14006A0212014-02-0606 February 2014 Requests for Additional Information for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application- Aging Management, Set 8 Project stage: RAI ML14023A5642014-02-0707 February 2014 RAI for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application, Set 13 Project stage: RAI ML14030A5962014-02-10010 February 2014 Requests for Additional Information for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application, Set 12 Project stage: RAI ML14007A6032014-02-18018 February 2014 Request for Additional Information for the Review of the Byron Nuclear Station, Units 1 and 2, and Braidwood Nuclear Station, Units 1 and 2, LRA - Aging Management - Set 17 Project stage: RAI ML14034A0682014-02-18018 February 2014 Request for Additional Information for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application, Set 11 Project stage: RAI ML14035A5342014-02-20020 February 2014 January 22, 2014, Summary of Telephone Conference Call Held Between NRC and Exelon Generation Company, Llc., Concerning Draft Requests for Additional Information Pertaining to the Byron Station and Braidwood Station, License Renewal Applica Project stage: Draft RAI ML14035A1892014-02-20020 February 2014 Summary of Telephone Conference Call Held on January 30, 2014, Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Draft Request for Additional Information Pertaining to the Byron Station and Braidw Project stage: Draft RAI ML14050A1222014-02-24024 February 2014 Summary of Telephone Conference Call Held on January 16, 2014, Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning RAI Set 7, Tor the Byron-Braidwood License Renewal Application (TAC Nos. MF1879, Mf Project stage: RAI ML14038A3362014-02-26026 February 2014 Request for Additional Information for the Review of the Byron Nuclear Station, Units 1 and 2, and Braidwood Nuclear Station, Units 1 and 2, License Renewal Application - Aging Management - Set 10 Project stage: RAI RS-14-051, Response to NRC Requests for Additional Information, Set 8, Dated February 6, 2014 Related to the License Renewal Application2014-02-27027 February 2014 Response to NRC Requests for Additional Information, Set 8, Dated February 6, 2014 Related to the License Renewal Application Project stage: Response to RAI ML14063A4952014-03-0404 March 2014 Response to NRC Requests for Additional Information, Set 13, Dated February 7, 2014 Re License Renewal Application Project stage: Response to RAI ML14051A4312014-03-0404 March 2014 Summary of Telephone Conferene Call Held on January 29, 2014, Between the NRC and Exelon Generating Company, Llc., Concerning RAI Set 10, for the Byron and Braidwood Station License Renewal Application (TAC Nos. MF1879, MF1880, MF1881, and Project stage: RAI ML14036A3102014-03-0404 March 2014 Summary of Telephone Conference Call Held on January 28, 2014, Between NRC and Exelon, Concerning RAI Set 10, for the Byron and Braidwood Station, LRA Project stage: RAI ML14050A1672014-03-0404 March 2014 Summary of Telephone Conference Call on January 23, 2014, Between U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning RAI Set 11, for Byron-Braidwood License Renewal Application (TAC Nos. MF1879, MF1880, MF1881 Project stage: RAI ML14051A4282014-03-0606 March 2014 January 13, 2014, Summary of Telephone Conference Call Held Between the NRC and Exelon RAI Set 8, for the Byron and Braidwood Station LRA Project stage: RAI ML14050A0812014-03-0707 March 2014 Correction to Request for Additional Information B.2.1.10-1, Letter Dated February 7, 2014, for the Review of the Byron Station and Braidwood Station, Units 1 and 2, LRA Set 13 Project stage: RAI ML14064A3912014-03-11011 March 2014 Request for Additional Information for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application, Set 15 Project stage: RAI ML14064A4032014-03-11011 March 2014 Summary of Telephone Conference Call on February 27, 2014, Between U.S. Nuclear Regulatory Commission & Exelon Generation Company, LLC Concerning Draft Request for Additional Information Re Byron Station & Braidwood Station License Renewal Project stage: Draft RAI ML14058B1802014-03-11011 March 2014 Summary of Telephone Conference Call on February 18, 2014, Between U.S. Nuclear Regulatory Commission & Exelon Generation Company, LLC Concerning Draft Request for Additional Information Regarding Byron & Braidwood Stations, License Renewal Project stage: Draft RAI ML14072A3692014-03-13013 March 2014 AMP Audit Enclosure (3) Project stage: Other ML14071A6202014-03-13013 March 2014 Aging Management Programs Audit Report Regarding the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2 (Tac Nos. MF1879, MF1880, MF1881, and MF1882) Project stage: Other ML14050A3042014-03-14014 March 2014 Scoping and Screening Methodology Audit Report Regarding the Byron Station, and Braidwood Station, Units 1 and 2, LRA Project stage: Other ML14058B1822014-03-18018 March 2014 Request for Additional Information for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application, Set 14 Project stage: RAI ML14051A5032014-03-20020 March 2014 Request for Additional Information for the Review of the Byron Nuclear Station Units 1 and 2, and Braidwood Nuclear Station, Units 1 and 2, License Renewal Application - Set 17 Project stage: RAI RS-14-084, Responses to NRC Requests for Additional Information, Set 10, Dated February 26, 2014 Related to the License Renewal Application2014-03-28028 March 2014 Responses to NRC Requests for Additional Information, Set 10, Dated February 26, 2014 Related to the License Renewal Application Project stage: Response to RAI ML14073A7052014-04-0303 April 2014 Summary of Telephone Conference Call Held on February 12, 2014, Between the NRC and Exelon, Concerning Drais Pertaining to the Byron and Braidwood Station, LRA Project stage: RAI ML14084A3352014-04-0303 April 2014 Request for Additional Information for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application, Set 16 Project stage: RAI ML14084A4882014-04-0707 April 2014 Summary of Telephone Conference Call Held Between NRC and Exelon Generation Company, LLC, Concerning Draft Request for Additional Information Pertaining to the Byron and Braidwood License Renewal Application Set 16 Project stage: Draft RAI ML14092A2612014-04-0707 April 2014 Request for Additional Information for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application, Set 20 Project stage: RAI ML14092A3462014-04-0707 April 2014 Project Manager Change for the License Renewal of Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2 Project stage: Other ML14094A3662014-04-0808 April 2014 Request for Additional Information for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application, Set 19 Project stage: RAI ML14093B2472014-04-10010 April 2014 Request for Additional Information for the Review of the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application, Set 18 Project stage: RAI ML14099A4852014-04-17017 April 2014 Request for Additional Information for the Review of the Byron Station, Units 1 & 2, and Braidwood Station, Units 1 & 2, License Renewal Application, Set 21, Project stage: RAI 2014-02-27
[Table View] |
Text
Mr. Michael P. Gallagher UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 13, 2014 Vice President, License Renewal Projects Exelon Generation Company, LLC 200 Exelon Way Kennett Square, PA 19348
SUBJECT:
REQUESTS FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE BYRON NUCLEAR STATION, UNITS 1 AND 2, AND BRAIDWOOD NUCLEAR STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION, SET 6 (TAC NOS. MF1879, MF1880, MF1881, AND MF1882)
Dear Mr. Gallagher:
By letter dated May 29, 2013, Exelon Generation Company, LLC, submitted an application pursuant to Title 10 of the Code of Federal Regulation (CFR) Part 54, to renew the operating licenses NPF-37, NPF-66, NPF-72, and NPF-77 for Byron Nuclear Station, Units 1 and 2, and Braidwood Nuclear Station, Units 1 and 2, respectfully, for review by the U.S. Nuclear Regulatory Commission staff. The staff is reviewing the information contained in the license renewal application and has identified, in the enclosure, areas where additional information is needed to complete the review.
These requests for additional information were discussed with John Hufnagel, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me at 301-415-4115 or by e-mail L:ndsay.Robinson@nrc.gov.
Sincerely, Lindsay R. Robinson, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-454, 50-455, 50-456, and 50-457
Enclosure:
Requests for Additional Information cc w/encl: Listserv
ML13317A075 OFFICE LA:DLR PM:RPB1 :DLR PM:RPB1 :DLR BC:RPB1 :DLR NAME I King LRobinson
~Daily YDiaz-Sanabria DATE 11/14/2013 11/14/2013 1/13/2014 1/13/2014
Letter toM. Gallagher from L. Robinson dated January 13,2014
SUBJECT:
REQUESTS FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE BYRON NUCLEAR STATION, UNITS 1 AND 2, AND BRAIDWOOD NUCLEAR STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION, SET 6 (TAC NOS. MF1879, MF1880, MF1881, AND MF1882)
DISTRIBUTION EMAIL:
PUBLIC RidsNrrDir Resource RidsNrrDirRpb1 Resource RidsNrrDirRasb Resource RidsOgcMaiiCenter LRobinson JDaily DMclntyre, OPA JWiebe, DORL EDuncan, Rill JBenjamin, Rill AGarmoe, Rill SR1, Byron Station, Rill JRobbins, Rill VMitlyng, Rill PChandrathil, Rill
RAI B.2.1.38-1 Applicability:
BYRON NUCLEAR STATION, UNITS 1 AND 2 AND BRAIDWOOD NUCLEAR STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION REQUESTS FOR ADDITIONAL INFORMATION-SET 6 (TAC NOS. MF1879, MF1880, MF1881, AND MF1882)
Byron Station (Byron) and Braidwood Station (Braidwood), all units.
Background:
The applicant stated that license renewal application (LRA) aging management program (AMP)
B.2.1.38, "Insulation Material For Electrical Cables and Connections Not Subject To 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits," is a new program that is consistent with NUREG-1801 AMP XI.E2, "Insulation Material For Electrical Cables and Connections Not Subject To 10 CFR 50.49 Environmental Qualification Requirements Used In Instrumentation Circuits."
The "scope of program" program element of the LRA AMP states that the in-scope cables and connections that are used in instrumentation circuits with sensitive, high voltage, low level current signals, which are not part of the EQ program, are within the scope of this program. The applicant further stated that portions of the radiation monitoring system and portions of the reactor protection system are in scope of the program. For Braidwood, the applicant stated that source range/intermediate range neutron monitoring circuits (SR/IR) are in-scope of this program. For Byron, the SR and IR are not in scope of the program because they are managed by the Environmental Qualification of Electric Components program. Power range neutron monitoring circuits (PR) are not stated in scope for any LRA AMPs.
The Generic Aging Lessons Learned (GALL) Report AMP recommends that this AMP applies to electrical cables and connections (cable system) used in circuits with sensitive, high voltage, low-level current signals, such as radiation monitoring and nuclear instrumentation, that are subject to aging management review and installed in adverse localized environments caused by temperature, radiation, or moisture.
Issue:
The applicant did not identify power range neutron monitoring circuits as in scope of this AMP for both Byron and Braidwood or explain why these circuits are not in scope of this program.
Request:
Explain why power range neutron monitoring circuits are not in scope of AMP B.2.1.38 for both Byron and Braidwood.
ENCLOSURE RAI 8.2.1.38-2 Applicability:
Byron and Braidwood, all units.
Background:
The applicant stated that LRA AMP B.2.1.38, "Insulation Material For Electrical Cables and Connections Not Subject To 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits," is a new program that is consistent with NUREG-1801 AMP XI.E2, "Insulation Material For Electrical Cables and Connections Not Subject To 10 CFR 50.49 Environmental Qualification Requirements Used In Instrumentation Circuits."
The "detection of aging effects" program element of LRA AMP B.2.1.38 states that cable system testing will be credited as an alternative approach to the review of surveillance or calibration results and will be performed using a proven, industry accepted, cable system test for detecting deterioration of the insulation system.
The GALL Report AMP recommends that cable testing be conducted when the calibration or surveillance program does not include the cabling system in the testing circuit. A proven cable system test for detecting deterioration of the insulation system (such as insulation resistance tests, time domain reflectometry tests, or other testing judged to be effective in determining cable system insulation as justified in the application) should be performed.
Issue:
The GALL Report recommends cable system testing when the calibration or surveillance program does not include the cable system. The applicant's AMP could allow reviewing of calibration results even though the cable system is not included in the calibration or surveillance program. The applicant's AMP states that a proven, industry accepted, cable system test for detecting deterioration for the insulation will be performed. However, the applicant does not identify the type of test that can be used. In the absence of these testing techniques, the staff cannot determine the consistency of the "detection of aging effects" program element to the GALL Report.
Request:
Clarify the cable system test requirements applicability. Also, identify the testing techniques to be used for detecting deterioration of the insulation system for nuclear instrumentation circuits.
RAI 8.2.1.38-3 Applicability:
Byron and Braidwood, all units.
Background:
The applicant stated that LRA AMP B.2.1.38, "Insulation Material For Electrical Cables and Connections Not Subject To 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits," is a new program that is consistent with NUREG-1801 AMP XI.E2, "Insulation Material For Electrical Cables and Connections Not Subject To 10 CFR 50.49 Environmental Qualification Requirements Used In Instrumentation Circuits."
Standard Review Plan (SRP), Table 3.0-1, Final Safety Analysis Report (FSAR) Supplement for Aging Management of Applicable Systems under AMP XI.E2, states that in cases where cables are not part of a calibration or surveillance program, a proven test (such as insulation resistance tests, time domain reflectometry tests, or other test judged to be effective as justified in the application) for detecting deterioration of insulation system are performed. LRA Section A.2.1.38 states that a proven cable test is performed in cases where cables are not included as part of the calibration or surveillance program testing circuit.
Issue:
The applicant does not identify the type of tests (e.g., such as insulation resistance tests, time domain reflectometry tests, or other test judged to be effective as justified in the application) that can be used in the updated FSAR (UFSAR) Supplement. In the absence of these testing techniques, the UFSAR Supplement is inconsistent with GALL Report AMP XI.E2 and SRP Table 3.0-1 which provides guidance on the specific tests.
Request:
Provide the testing techniques to be used for detecting deterioration of the instrumentation circuit insulation system.
RAI 8.2.1.41-1 Applicability:
Byron only.
Background:
The applicant stated that LRA AMP B.2.1.41, "Fuse Holders," is a new condition monitoring program that is consistent with NUREG-1801 AMP XI.E5, "Fuse Holders."
The "acceptance criteria" program element of the applicant's site AMP Basis Document states the thermography program establishes acceptance criteria for thermography testing. When thermography is not practical, other acceptance tests are implemented, such as connection resistance measurement. The AMP Basis Document states: "Acceptance criteria are set in accordance with good practice."
The GALL Report AMP recommends the acceptance criteria for each test are defined by the specific type of test performed and the specific type of fuse holder tested. The temperature of the metallic clamp of the fuse holder needs to be below the maximum allowed temperature for the application when thermography is used; otherwise, a low resistance value appropriate for the application when resistance measurement is used.
Issue:
"Acceptance criteria set in accordance with good practice" is unclear. An acceptance criterion consistent with the GALL Report needs to be established in order for the applicant to take corrective action. Acceptance criteria ensure that the intended function of the fuse holders can be maintained consistent with the current license basis.
Request:
Explain why the establishment of AMP B.2.1.41 "acceptance criteria as accordance with good practice" is consistent with the GALL Report and not an enhancement or exception.
RAI 8.2.1.42-1 Applicability:
Byron and Braidwood, all units.
Background:
The applicant stated that LRA AMP B.2.1.42, "Electrical Cable Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements," is a new program that is consistent with NUREG-1801 aging management program XI.E6, "Electrical Cable Connections Not Subject To 10 CFR 50.49 Environmental Qualification Requirements."
The GALL Report AMP XI.E6 states, "twenty percent of the population with a maximum sample of 25 constitutes a representative sample size. Otherwise a technical justification of the methodology and sample size used for selecting components for one-time test should be included as part of the AMP's site documentation."
The "detection of aging effects" program element of the applicant's site AMP Basis Document states the technical basis for the sample size is documented per station procedures. In addition, the site AMP Basis Document states that a representative sample size is twenty percent of the population with a maximum sample of 25 connections.
Issue:
Based on the applicant's AMP Basis Document, the applicant could select a sample size/method that is inconsistent from the GALL Report AMP XI.E6 recommendation without an evaluation by the staff.
Request:
Clarify if the sample size selection will be consistent with GALL Report AMP XI.E6 recommendation. If it is different than the GALL Report, provide a technical justification of the methodology and sample size used for selecting components.