W&,"F CREEK WNUCLEAR OPERATING CORPORATION Michael J. Westman August 7, 2013 Manager Regulatory Affairs RA 13-0091 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
Reference:
Letter RA 13-0052, dated April 29, 2013, from M. Westman, WCNOC, to USNRC
Subject:
Docket No. 50-482: Correction to Wolf Creek Generating Station 2012 Annual Radioactive Effluent Release Report - Report 36 Gentlemen:
Enclosed are corrected pages from the "Wolf Creek Generating Station 2012 Annual Radioactive Effluent Release Report - Report 36." Subsequent to the original submittal of this report, numerous errors were discovered on pages 28-35 of the report in the "Hours at Each Wind Speed and Direction" tables for all stability classifications.
These errors involved inaccurate trending data and the summation of the data in the tables, and had no impact on the curies released or the projected dose.
Wolf Creek Nuclear Operating Corporation (WCNOC) has corrected those errors and has enclosed corrected copies of the eight affected pages to replace those originally submitted in the reference. WCNOC regrets any inconvenience these errors may have caused.
This letter contains no commitments. If you have any questions concerning this matter, please contact me at (620) 364-4009 or Mr. William Muilenburg at (620) 364-4186.
Sincerely, Michael J. Westman MJW/rlt Enclosure cc:
A. T. Howell (NRC), w/e C. F. Lyon (NRC), w/e N. F. O'Keefe (NRC), w/e Senior Resident Inspector (NRC), w/e P.O. Box 411 / Burlington, KS 66839 /Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HCNET
Enclosure to RA 13-0091 Corrected Pages 28-35 of the Wolf Creek Generating Station 2012 Annual Radioactive Effluent Release Report - Report 36 (8 pages)
Period of Record:
Stability Class:
Elevation:
Hours At Each Wind Speed and Direction JANUARY 1 THROUGH DECEMBER 31, 2012 A
10 Meters Wind Direction Wind Speed( mph)
Cardinals 1-3 4-7 8-12 13-18 19-24
> 24 Total N
0.75 7.00 28.00 28.00 6.25 0.00 70.00 NNE 1.00 22.50 36.50 15.50 0.75 0.00 76.25 NE 0.75 28.75 24.50 1.75 0.00 0.00 55.75 ENE 0.75 11.50 19.00 0.25 0.00 0.00 31.50 E
0.75 18.75 29.50 1.00 0.00 0.00 50.00 ESE 0.25 11.25 22.25 2.50 1.25 0.00 37.50 SE 1.25 13.75 23.50 4.00 0.00 0.00 42.50 SSE 1.75 23.00 85.75 48.25 15.00 4.75 178.50 S
1.50 19.75 74.50 116.75 43.50 16.00 272.00 SSW 0.50 10.75 36.50 78.00 11.25 0.75 137.75 SW 2.00 7.75 18.00 6.50 0.00 0.00 34.25 WSW 0.50 13.00 12.25 1.50 0.00 0.00 27.25 W
1.25 21.50 25.25 6.75 1.50 1.00 57.25 WNW 1.00 14.25 11.25 10.75 3.25 4.50 45.00 NW 0.25 7.50 13.75 25.75 8.00 0.00 55.25 NNW 0.00 5.75 18.00 40.50 10.50 0.75 75.50 Total 14.25 236.75 478.50 387.75 101.25 27.75 1246.25 Hours of Calm
(<1.0 mph):
24.75 Page 28 of 61
Hours At Each Wind Speed and Direction Period of Record:
Stability Class:
Elevation:
JANUARY 1 B
10 Meters THROUGH DECEMBER 31, 2012 Wind Direction Wind Speed (mph)
Cardinals 1-3 4-7 8-12 13-18 19-24
> 24 Total N
0.25 7.75 18.25 9.75 1.00 0.00 37.00 NNE 2.25 13.50 14.75 8.25 2.50 0.00 41.25 NE 1.50 20.50 5.50 0.25 0.00 0.00 27.75 ENE 0.75 7.25 5.25 0.50 0.00 0.00 13.75 E
1.25 9.75 8.75 0.50 0.00 0.00 20.25 ESE 0.50 7.25 4.50 0.25 0.75 0.00 13.25 SE 1.25 7.50 6.50 2.75 0.50 0.00 18.50 SSE 1.25 13.50 18.25 8.25 1.25 1.00 43.50 S
1.75 17.00 17.00 16.75 8.25 2.00 62.75 SSW 0.75 9.25 12.00 16.25 3.50 1.25 43.00 SW 0.50 5.25 4.25 2.00 0.00 0.00 12.00 WSW 1.25 11.25 2.00 1.00 0.00 0.00 15.50 W
1.00 10.50 7.50 1.00 0.50 0.25 20.75 WNW 1.25 6.75 5.50 1.75 1.25 1.00 17.50 NW 0.25 6.00 9.00 11.25 6.25 1.25 34.00 NNW 1.00 5.75 12.50 10.25 3.25 0.25 33.00 Total 16.75 158.75 151.50 90.75 29.00 7.00 453.75 Hours of Calm
(<1.0 mph):
5.00 Page 29 of 61
Period of Record:
Stability Class:
Elevation:
Hours At Each Wind Speed and Direction JANUARY 1 THROUGH DECEMBER 31, 2012 C
10 Meters Wind Direction Wind Speed (m ph)
Cardinals 1-3 4-7 8-12 13-18 19-24
> 24 Total N
1.75 12.00 12.75 11.50 2.00 0.25 40.25 NNE 2.50 14.75 15.50 7.25 1.00 0.00 41.00 NE 3.25 14.50 7.50 0.75 0.00 0.00 26.00 ENE 1.00 13.00 5.50 0.25 0.00 0.00 19.75 E
0.00 12.00 7.00 0.50 0.00 0.00 19.50 ESE 1.00 5.25 7.25 1.25 0.75 0.00 15.50 SE 1.50 9.25 6.75 3.00 1.50 0.00 22.00 SSE 1.50 18.25 16.00 9.50 1.50 0.50 47.25 S
3.00 16.00 12.50 14.25 7.25 4.75 57.75 SSW 2.00 9.00 12.50 15.00 4.75 1.50 44.75 SW 2.00 8.50 2.75 2.00 0.25 0.00 15.50 WSW 4.25 12.00 1.75 0.50 0.00 0.00 18.50 W
3.25 7.25 5.00 1.00 0.25 0.00 16.75 WNW 2.25 4.00 3.00 1.75 1.25 0.50 12.75 NW 1.50 4.50 4.75 10.25 5.25 1.75 28.00 NNW 2.00 4.25 11.25 10.00 4.50 0.25 32.25 Total 32.75 164.50 131.75 88.75 30.25 9.50 457.50 Hours of Calm
(<1.0 mph):
3.50 Page 30 of 61
Period of Record:
Stability Class:
Elevation:
Hours At Each Wind Speed and Direction JANUARY 1 THROUGH DECEMBER 31, 2012 D
10 Meters Wind Direction Wind Speed mph)
Cardinals 1-3 4-7 8-12 13-18 19-24
> 24 Total N
10.25 42.50 84.50 59.75 14.25 1.25 212.50 NNE 15.00 71.00 60.50 30.00 0.50 0.00 177.00 NE 19.00 50.50 30.50 1.75 0.00 0.00 101.75 ENE 10.75 38.00 30.50 4.75 0.25 0.00 84.25 E
16.00 31.00 29.75 6.75 1.25 0.00 84.75 ESE 11.75 30.00 35.25 11.25 8.00 0.25 96.50 SE 12.00 50.00 43.00 12.50 2.25 0.00 119.75 SSE 14.25 41.25 113.25 109.50 31.50 3.75 313.50 S
10.25 49.50 127.00 142.25 66.75 20.25 416.00 SSW 10.50 43.00 62.75 56.25 14.50 1.25 188.25 SW 10.25 35.25 14.75 5.50 0.25 0.50 66.50 WSW 8.75 28.50 13.25 6.75 1.25 1.50 60.00 W
4.25 23.75 18.00 9.25 1.75 1.25 58.25 WNW 4.00 13.50 23.00 27.50 6.75 2.00 76.75 NW 4.50 25.75 52.00 58.25 31.50 12.50 184.50 NNW 4.25 46.25 85.25 90.75 25.50 3.75 255.75 Total 165.75 619.75 823.25 632.75 206.25 48.25 2496.00 Hours of Calm
(<1.0 mph):
16.00 Page 31 of 61
Period of Record:
Stability Class:
Elevation:
Hours At Each Wind Speed and Direction JANUARY 1 THROUGH DECEMBER 31, 2012 E
10 Meters Wind Direction Wind Speed (m ph)
Cardinals 1-3 4-7 8-12 13-18 19-24
> 24 Total N
9.00 47.25 40.00 10.75 0.50 0.00 107.50 NNE 17.25 45.75 14.25 2.25 0.00 0.00 79.50 NE 21.50 48.00 9.75 0.50 0.00 0.00 79.75 ENE 7.25 42.50 9.00 0.00 0.00 0.00 58.75 E
12.75 41.25 19.50 1.25 0.00 0.00 74.75 ESE 14.00 50.25 33.25 3.25 0.00 0.00 100.75 SE 9.25 82.00 71.50 8.00 0.25 0.00 171.00 SSE 8.25 91.50 225.75 113.75 23.75 4.75 467.75 S
6.25 60.50 130.00 158.25 58.25 28.00 441.25 SSW 8.50 41.75 84.00 21.50 1.00 0.50 157.25 SW 11.50 48.00 11.50 2.75 0.00 0.00 73.75 WSW 13.75 32.50 12.00 4.25 0.25 0.00 62.75 W
4.50 27.75 12.00 4.00 0.25 0.00 48.50 WNW 5.25 24.25 18.00 10.75 0.75 0.00 59.00 NW 6.50 29.00 27.00 2.75 1.50 1.25 68.00 NNW 10.50 38.75 52.25 11.50 1.75 0.50 115.25 Total 166.00 751.00 769.75 355.50 88.25 35.00 2165.50 Hours of Calm
(<1.0 mph):
58.50 Page 32 of 61
Hours At Each Wind Speed and Direction Period of Record:
Stability Class:
Elevation:
JANUARY F
10 Meters 1 THROUGH DECEMBER 31, 2012 Wind Direction
_Wind Speed (m ph)
Cardinals 1-3 4-7 8-12 13-18 19-24
> 24 Total N
9.50 68.25 6.00 0.25 0.00 0.00 84.00 NNE 28.00 51.00 3.50 0.00 0.00 0.00 82.50 NE 32.75 33.00 1.00 0.00 0.00 0.00 66.75 ENE 8.25 41.75 1.50 0.25 0.00 0.00 51.75 E
14.75 55.50 3.75 0.25 0.00 0.00 74.25 ESE 11.00 82.75 6.50 0.00 0.00 0.00 100.25 SE 18.50 110.00 11.00 0.00 0.00 0.00 139.50 SSE 11.25 71.25 42.75 2.50 0.00 0.00 127.75 S
7.75 28.00 18.00 14.00 3.00 0.00 70.75 SSW 9.50 17.75 12.00 2.00 0.00 0.00 41.25 SW 12.25 35.50 1.25 0.25 0.00 0.00 49.25 WSW 10.25 14.75 2.25 0.25 0.25 0.00 27.75 W
9.75 9.00 1.00 0.00 0.00 0.00 19.75 WNW 5.50 10.00 1.25 0.00 0.00 0.00 16.75 NW 6.75 19.75 3.50 0.00 0.00 1.00 31.00 NNW 10.50 47.25 11.00 0.25 0.00 0.00 69.00 Total 206.25 695.50 126.25 20.00 3.25 1.00 1052.25 Hours of Calm
(<1.0 mph):
5.00 Page 33 of 61
Hours At Each Wind Speed and Direction Period of Record:
Stability Class:
Elevation:
JANUARY G
10 Meters 1 THROUGH DECEMBER 31, 2012 Wind Direction Wind Speed (mph)
Cardinals 1-3 4-7 8-12 13-18 19-24
> 24 Total N
11.75 30.25 2.50 0.00 0.00 0.00 44.50 NNE 42.50 68.50 0.50 0.00 0.00 0.25 111.75 NE 51.75 34.75 0.25 0.00 0.00 0.00 86.75 ENE 8.50 40.50 1.75 0.00 0.00 0.00 50.75 E
11.75 48.00 2.50 0.00 0.00 0.00 62.25 ESE 9.75 65.25 0.25 0.00 0.00 0.00 75.25 SE 15.25 61.50 0.25 0.25 0.00 0.00 77.25 SSE 13.00 35.25 1.00 0.00 0.00 0.00 49.25 S
7.75 13.00 1.75 0.25 0.00 0.00 22.75 SSW 3.25 2.75 1.00 0.00 0.00 0.00 7.00 SW 3.25 3.75 0.25 0.00 0.00 0.00 7.25 WSW 6.00 2.75 0.00 0.00 0.00 0.00 8.75 W
4.25 3.25 0.00 0.00 0.00 0.00 7.50 WNW 8.75 2.25 0.00 0.00 0.00 0.00 11.00 NW 12.25 21.75 1.50 0.00 0.00 0.25 35.75 NNW 10.00 24.75 10.50 0.00 0.00 0.00 45.25 Total 219.75 458.25 24.00 0.50 0.00 0.50 703.00 Hours of Calm
(<1.0 mph):
7.25 Page 34 of 61
Period of Record:
Stability Class:
Elevation:
Hours At Each Wind Speed and Direction JANUARY 1 THROUGH DECEMBER 31, 2012 ALL 10 Meters Wind Direction Wind Speed (mph)
Cardinals 1-3 4-7 8-12 13-18 19-24
> 24 Total N
43.25 215.00 192.00 120.00 24.00 1.50 595.75 NNE 108.50 287.00 145.50 63.25 4.75 0.25 609.25 NE 130.50 230.00 79.00 5.00 0.00 0.00 444.50 ENE 37.25 194.50 72.50 6.00 0.25 0.00 310.50 E
57.25 216.25 100.75 10.25 1.25 0.00 385.75 ESE 48.25 252.00 109.25 18.50 10.75 0.25 439.00 SE 59.00 334.00 162.50 30.50 4.50 0.00 590.50 SSE 51.25 294.00 502.75 291.75 73.00 14.75 1227.50 S
38.25 203.75 380.75 462.50 187.00 71.00 1343.25 SSW 35.00 134.25 220.75 189.00 35.00 5.25 619.25 SW 41.75 144.00 52.75 19.00 0.50 0.50 258.50 WSW 44.75 114.75 43.50 14.25 1.75 1.50 220.50 W
28.25 103.00 68.75 22.00 4.25 2.50 228.75 WNW 28.00 75.00 62.00 52.50 13.25 8.00 238.75 NW 32.00 114.25 111.50 108.25 52.50 18.00 436.50 NNW 38.25 172.75 200.75 163.25 45.50 5.50 626.00 Total 821.50 3084.50 2505.00 1576.00 458.25 129.00 8574.25 Hours of Calm Maximum Hours of
(<1.0 mph): 120.00 Invalid Data:
89.75 Page 35 of 61