ML13142A310

From kanterella
Jump to navigation Jump to search
Operating Corp. - Annual Radiological Environmental Operating Report
ML13142A310
Person / Time
Site: Wolf Creek 
Issue date: 04/24/2013
From: Westman M
Wolf Creek
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RA 13-0053
Download: ML13142A310 (166)


Text

W$LF CREEK NUCLEAR OPERATING CORPORATION Michael J. Westman Manager Regulatory Affairs April 24, 2013 RA 13-0053 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Subject:

Docket No. 50-482: 2012 Annual Radiological Environmental Operating Report Gentlemen:

The purpose of this letter is to submit the enclosed Annual Radiological Environmental Operating Report, which is being submitted pursuant to Wolf Creek Generating Station (WCGS) Technical Specification 5.6.2.

This report covers radiological environmental monitoring around WCGS for the period of January 1, 2012, through December 31, 2012.

This letter contains no commitments. If you have any questions concerning this matter, please contact me at (620) 364-8831 ext. 4009, or Mr. William Muilenburg, at (620) 364-8831, ext.

4511.

Sincerely, Michael J. Westman MJW/rlt

Enclosure:

2012 Annual Radiological Environmental Operating Report (165 pages) cc:

A. T. Howell (NRC), w/e C. F. Lyon (NRC), w/e N. F. O'Keefe (NRC), w/e Senior Resident Inspector (NRC), w/e PO. Box 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HC/VET

WOLF CREEK NUCLEAR OPERATING CORPORATION WOLF CREEK GENERATING STATION 2012 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT F

April 15, 2013

TABLE OF CONTENTS List of Tables ii List of Figures ii List of Charts ii Executive Summary 1

Introduction 1

I. Program Description 1

I1. Discussion of Results 4

I1l. Program Revisions/Changes 9

IV. Program Deviations 10 V. Interlaboratory Comparison Program 10 VI. Comparison to the Radioactive Effluent Release Program 10 Tables 12 Figures 21 Charts 26 Appendix A - Interlaboratory Comparison Program Results A-1 Appendix B - Summary Tables B-1 Appendix C - Individual Sample Results C-1 Air Particulate and Charcoal Filters C-1 Quarterly Air Particulate - Gamma C-13 Surface Water C-1 9 Ground Water C-27 Drinking Water C-43 Quarterly Drinking Water - Tritium C-51 Shoreline Sediment C-53 Fish C-57 Food/Garden C-63 Feed and Forage C-74 Bottom Sediment C-77 Aquatic Vegetation C-94 Terrestrial Vegetation C-98 Soil C-99 Deer C-100 Appendix D - Land Use Census Report D-1

LIST OF TABLES 1 Radiological Environmental Monitoring Program Description 12 2

Sample Location Identifiers, Distances (Miles) and Directions (Sectors) 17 3

OSL Dosimeter Results 20 LIST OF FIGURES 1 Airborne Pathway Sampling Locations 21 2

Direct Radiation Pathway Sampling Locations 22 3 Waterborne Pathway Sampling Locations 23 4

Ingestion Pathway Sampling Locations 24 5

Distant Sampling Locations 25 LIST OF CHARTS 1 Airborne Gross Beta Weekly Results 26 2

Historical Airborne Smoothed Indicator and Control Gross Beta 27 3

OSL Dosimeters - Indicator and Control Locations mR per Standardized 90-day 28 Quarter 4

Historical TLD Nearsite Locations and Control Locations 29 5

Coffey County Lake Surface Water Tritium Data 30 6

Drinking Water Gross Beta (5 years) 31 7

Detected Cs-137 Activity in Bottom Sediment 32 ii

EXECUTIVE

SUMMARY

Plant-related activation, corrosion, or fission products were not detected during 2012 in airborne particulate and radioiodine filters, ground water, broadleaf vegetation, shoreline sediment, crops, aquatic vegetation, terrestrial vegetation, bottom sediment, or soil samples. Activation, corrosion or fission products attributable to plant operation were detected during 2012 in surface water, fish, drinking water, and deer samples.

Nuclides detected in Radiological Environmental Monitoring Program (REMP) samples were below applicable Nuclear Regulatory Commission (NRC) reporting levels.

Based upon the radiological environmental monitoring program results, it was concluded station operations had no significant radiological impact on the health and safety of the public or the environment.

INTRODUCTION The 2012 Annual Radiological Environmental Operating Report for Wolf Creek Generating Station (WCGS) covers the period from January 1 through December 31, 2012.

WCGS is located in Coffey County, Kansas, approximately five miles northeast of Burlington, Kansas.

Fuel loading commenced at WCGS on March 12, 1985. The operational phase of the REMP began with initial criticality on May 22, 1985, and the first detectable quantities of radioactivity were reported in plant effluents in June 1985.

This report contains a description of the REMP conducted by Wolf Creek Nuclear Operating Corporation (WCNOC), a discussion of monitoring program results, the revisions or changes to the program, program deviations, the Interlaboratory Comparison Program and a comparison to the Radioactive Effluent Release Program. The Interlaboratory Comparison Program results, a summary of results in the NRC Branch Technical Position specified format, the individual sample results, and the Land Use Census Report are included as appendices.

I. PROGRAM DESCRIPTION Radiological environmental monitoring samples were collected according to the schedule in WCGS procedure AP 07B-004, Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program). Radiological environmental monitoring program samples were collected by the WCGS Environmental Management group and were analyzed by Environmental, Inc.

Landauer, Inc. processed the environmental optically stimulated luminescence (OSL) dosimeters. Table 1 identifies the exposure pathway/sample type, number of samples/sample locations, sample collection frequency and type/frequency of analysis. Table 2 lists the sample location identifiers, distances and directions from the plant.

Samples in addition to those required by the WCGS Offsite Dose Calculation Manual (ODCM) were also obtained and analyzed.

The following is a description of the sampling and analysis program by individual pathways.

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 1 of 32

A. Airborne Pathway Low volume air sampling pumps with digital flow meters continuously collected particulate and radioiodine samples on 47 mm glass fiber filters and charcoal canisters, respectively.

The filters and charcoal canisters were changed out weekly. Gross beta analysis was performed on the air particulate filters. Air particulate filters were also analyzed quarterly for gamma emitting isotopes. Charcoal canisters were analyzed for 1-131.

Air samples were collected from six locations. The five indicator locations sampled included 2, 18, 32, 37 and 49. A control location near the intersection of 2 0 th Road and Yearling Road (location 53) was also sampled.

Indicator locations are shown in Figure 1 and the control location is shown in Figure 5.

B. Direct Radiation Pathway Optically stimulated luminescence (OSL) dosimeters were used at 43 locations during the sample year to measure direct radiation. The OSLs were typically positioned roughly 3 to 4 feet above the ground in plastic thermostat boxes. Three OSLs were placed at each designated location. The OSLs were changed out quarterly. Transit dose was measured and subtracted from the ambient dose. Indicator OSL sample locations are illustrated in Figure 2 and control locations are shown in Figure 5. Control locations were 39 (Beto Junction) and 53 (near the intersection of 2 0 th Road and Yearling Road).

C. Waterborne Pathway Water samples were analyzed to determine if gamma emitters were present.

In addition to gamma isotopic analysis, radiochemical analysis for 1-131 was performed on drinking water and ground water samples. Gross beta analysis was also performed on drinking water samples.

Tritium analysis was performed monthly by liquid scintillation for surface water and quarterly for drinking water. Tritium analysis was also performed on ground water samples. Four surface water samples from the Coffey County Lake Spillway (SP) location and four surface water samples from the John Redmond Reservoir (JRR) location were also analyzed for Fe-55. The waterborne pathway sample locations are shown in Figures 3 and 5.

Monthly grab samples of surface water were collected from the JRR control location and from the SP indicator location.

The SP indicator location is located near the spillway of Coffey County Lake, formerly known as Wolf Creek Lake.

Quarterly grab samples of ground water were collected from seven wells. Six locations (C-10, C-49, F-1, G-2, J-1 and J-2) located hydrologically down gradient from the site were used as indicator sample locations. Location B-12 located hydrologically up gradient from the site was used as a control location.

Drinking water was sampled at the water treatment facilities in the towns of Iola (indicator location IO-DW) and Burlington (control. location BW-15).

The Iola facility is located downstream of the site and the Burlington facility is located upstream of the confluence of the Coffey County Lake discharge and the Neosho River.

Composite samples were obtained monthly from automatic samplers at each location.

The samplers collected approximately 27 milliliters of water every two hours.

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 2 of 32

Shoreline sediments were sampled semiannually. Gamma isotopic analyses were performed on the shoreline sediment samples.

Shoreline sediment sample locations were the Coffey County Lake discharge cove. (DC) indicator location and the JRR control location.

D. Ingestion Pathway Milk was not collected during the sample year. The Land Use Census did not identify any locations producing milk for human consumption within five miles of the plant.

Fish were sampled semiannually from the Coffey County Lake (indicator location) and from the tail waters of JRR (control location). These sample locations are identified in Figure 4. Gamma isotopic analyses were performed on the boneless meat portions of the fish. Several species of game fish and rough fish were sampled. Fish were also analyzed for tritium.

Broadleaf vegetation samples were collected monthly when available during the growing season from five gardens. Four indicator (B-I, H-2, N-1 and Q-6) gardens (Figure 4) and one control (D-2) garden (Figure 5) were sampled. Gamma isotopic analyses were performed on these samples.

Crop samples were obtained from two indicator locations (NR-D1 and NR-D2) downstream of the confluence of Wolf Creek and the Neosho River. One crop sample was obtained from control location NR-U1.

Gamma isotopic analysis was performed on each sample.

Crop sample locations are identified on Figure 5.

E. Additional Samples Collected (not required by ODCM)

Quarterly, duplicate ground water grab samples were obtained from indicator location C-49 and were labeled L-49. These duplicate samples served as laboratory quality checks. The ground water samples were analyzed for gamma emitters, 1-131, and tritium.

Bottom sediment samples were collected from indicator locations at the Coffey County Lake discharge cove (DC), Environmental Education Area (EEA), Make-Up Discharge Structure (MUDS), Ultimate Heat Sink (UHS), Essential Service Water (ESW) channel, Stringtown Cemetery (SC) and the control location (JRR). Gamma isotopic analyses were performed on the bottom sediment samples. Samples obtained from DC, ESW and UHS were also analyzed for Fe-55. Some of the bottom sediment samples were collected as part of a cooperative sampling effort with the Kansas Department of Health and Environment (KDHE). The sample locations are identified on Figure 3.

Shoreline sediment samples were collected from indicator locations EEA and SC.

Gamma isotopic analyses were performed on the samples. These samples were collected as part of a cooperative sampling effort with the KDHE. The sample locations are identified on Figure 3.

Aquatic vegetation was collected from indicator locations DC ALT, EEA, MUDS and SC.

Gamma isotopic analyses were performed on the aquatic vegetation samples. These samples were collected as part of a cooperative sampling effort with the KDHE. The sample locations are identified on Figure 3.

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 3 of 32

Terrestrial vegetation (grass) was sampled from the EEA indicator location. Gamma isotopic analysis was performed on the grass sample.

This sample was collected as part of a cooperative sampling effort with the KDHE. The sample location is identified on Figure 4.

Soil was sampled from the EEA indicator location. Gamma isotopic analysis was performed on the soil sample. This sample was collected as part of a cooperative sampling effort with the KDHE. The sample location is identified on Figure 4.

A deer was sampled from indicator location A1.5. Gamma isotopic analysis and tritium analysis was performed. This sample was collected as part of a cooperative sampling effort with the KDHE. The sample location is identified on Figure 4.

II. DISCUSSION OF RESULTS Analysis results for pathways are summarized in Appendix B using the format described in Radiological Assessment Branch Technical Position, Revision 1, November 1979 (NRC Generic Letter 79-065). Results for individual samples are listed in Appendix C.

A. Airborne Pathway Chart 1 graphically illustrates weekly gross beta results for the sample year. Chart 2 represents the historical smoothed averages of indicator locations and the control locations gross beta data.

Charts 1 and 2 demonstrate how closely the indicator and control locations tracked together. Chart 2 reveals a seasonal cyclic trend; the gross beta values peak in the winter months (December or January) and decrease to a low point in the spring months (May or June).

This trend is expected and is attributed to seasonal meteorological changes, i.e., changes in prevailing winds and precipitation.

The gross beta results of 2012 were compared to pre-operational monitoring results of 1983 and 1984.

The weekly gross beta analyses range for 1983 and 1984 was 0.0064 to 0.084 pCi/m 3. The 2012 weekly gross beta analyses range for indicator locations was 0.009 to 0.064 pCi/m 3. The 2012 weekly gross beta analyses range was within the 1983 and 1984 pre-operational range. Additionally, the annual mean for indicator locations for 2012 (0.029 pCi/m 3) was lower than the annual mean for 1983 (0.032 pCi/m 3).

The gross beta results for the indicator locations were also compared to the control location.

The annual mean for indicator locations for 2012 (0.029 pCi/m 3) was the same as the annual mean of the control location (0.029 pCi/m 3). The indicator location with the highest gross beta annual mean was location 49 (0.031 pCi/mi

) and was slightly higher than the annual mean of the control location (0.029 pCi/m 3).

Naturally occurring Be-7 activity was detected, as was the case during pre-operational monitoring.

In 1984, the range for Be-7 detected activity was 0.024 to 0.211 pCi/m 3 for indicator locations and the annual mean for indicator locations was 0.069 pCi/m 3. In 2012, the range for Be-7 detected activity was 0.052 to 0.105 pCi/m 3 for indicator locations and the annual mean for indicator locations was 0.082 pCi/m 3.

The control location annual mean for Be-7 detected activity (0.090 pCi/m 3) was slightly higher than the annual mean of the indicator locations (0.082 pCi/m 3).

1-131 activity was not detected in the weekly analysis of charcoal filters at any location.

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 4 of 32

The ODCM required lower limits of detection were met. Plant-related activation, corrosion, or fission products were not detected during 2012 in airborne particulate and radioiodine filters and no unusual trends were noted.

B. Direct Radiation Pathway Quarterly OSL dosimeter results for each location are shown in Table 3. Measured values have been converted to a standardized 90-day quarter.

The annual mean of indicator locations in 2012 was 19.5 mR per standardized 90-day quarter.

The annual mean of the control locations in 2012 was 18.6 mR per standardized 90-day quarter.

For pre-operational comparison, in 1981, the annual mean of indicator locations was 18.9 mR per standardized 90-day quarter and the annual mean for the control locations was 17.1 mR per standardized 90-day quarter.

It should be noted WCGS changed from thermoluminescence dosimeters (TLD) to optically stimulated luminescence (OSL) dosimeters in 2008.

The indicator location with the highest annual mean was 47 (24.8 mR per standardized 90-day quarter). The close proximity of location 47 to the Radwaste Building is likely the reason direct radiation levels are higher at this location.

Based upon Condition Report 00027489, improvements were made in measuring and subtracting transit dose in 2010. As expected, the OSL results have increased since 2010.

Chart 3 visibly displays the increase of the OSL results. Chart 3 also displays how closely the indicator and control location OSL dosimeter results are for 2012.

Chart 4 displays the TLD nearsite locations (1, 2, 7-9, 11-14, 18, 26, 27, 29, 30, 37 and 38) and the control locations (locations 39 and 48) for the preoperational years through 2007.

C. Waterborne Pathway (1) Surface Water Tritium, attributable to WCGS operation, was detected in surface water samples collected from the Coffey County Lake Spillway (SP) indicator location during 2012. The annual mean for detected tritium activity at the SP location was 11,435 pCi/L and the range was 10,037 to 12,545 pCi/L. The detected tritium activity was below the 30,000 pCi/L ODCM reporting level.

Chart 5 illustrates the yearly averages of surface water tritium data for the spillway location.

Chart 5 indicates the average tritium concentration of the Coffey County Lake spillway location may have reached equilibrium. Tritium activity was not detected in samples obtained from the control location (JRR).

During pre-operational radiological environmental monitoring, measured radiological activity was not detected in surface water samples.

The ODCM required lower limits of detection were met. Radionuclides were not detected by the gamma isotopic analyses or by Fe-55 analyses.

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 5 of 32

Tritium was the only activity detected in surface water samples and no unusual trends were noted.

(2) Ground Water ODCM required lower limits of detection were met for 1-131, tritium and gamma isotopic analyses.

Radioactivity was not detected in any ground water samples.

No unusual trends were noted.

Plant-related activation, corrosion or fission products were not detected during 2012 in ground water samples.

(3) Drinking Water Gross beta activity was detected in drinking water samples collected from the indicator location and in samples collected from the control location. The annual mean of the indicator location gross beta activity (3.0 pCi/L) was slightly higher when compared to the annual mean of the control location gross beta activity (2.8 pCi/L). The 2012 annual means of gross beta activity for both the indicator and control locations were lower than those of the pre-operational monitoring year of 1984. In 1984, the annual mean of the indicator location gross beta activity was 7.5 pCi/L and the annual mean of the control location gross beta activity was 6.4 pCi/L.

Chart 6 illustrates the drinking water gross beta results for the last five years and how closely the gross beta results compared for the indicator and control locations.

Tritium activity (222 pCi/L) was detected in the first quarter of 2012 at the indicator location.

The detected tritium activity was well below the 20,000 pCi/L ODCM reporting level. Condition Report 00052766 concluded due to low Neosho River flows, coupled with wave overlap discharges from Coffey County Lake, WCGS was a plausible source. Tritium activity was not detected in 2012 at the control location.

In 1984 (pre-operational), tritium activity was not detected in any drinking water samples.

ODCM required lower limits of detection were met.

Additionally, radionuclides were not detected by the 1-131 or gamma isotopic analyses.

(4) Shoreline Sediment Naturally occurring K-40 was detected in shoreline sediment samples collected from the DC (indicator) and JRR (control) locations.

K-40 was also detected during pre-operational shoreline sediment monitoring.

ODCM required lower limits of detection were met. Plant-related activation, corrosion, or fission products were not detected during 2012 in shoreline sediment samples and no unusual trends were noted.

D. Ingestion Pathway (1) Milk Milk was not collected during the sample year since no indicator locations within five miles of the plant were identified during the Land Use Census.

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 6 of 32

(2) Fish Naturally occurring K-40 activity was detected in fish samples obtained from the CCL indicator location and in fish samples obtained from the JRR control location.

K-40 activity was also detected during pre-operational fish monitoring.

Fish samples were also analyzed for tritium. Fish samples collected from Coffey County Lake had tritium activity detected (7,728 pCi/kg annual mean).

The detected tritium activity was attributable to plant operation.

An adult consuming 21 kilograms of fish, at the maximum measured tritium concentration (8,948 pCi/kg), would receive a committed effective dose equivalent of 0.012 mRem.

Tritium activity was not detected in the control samples collected from JRR.

No other radionuclides were detected in fish during the year. The ODCM required lower limits of detection were met and no unusual trends were noted.

(3) Broadleaf Vegetation Gamma analyses of broadleaf vegetation samples obtained from indicator and control locations detected naturally occurring gamma emitters Be-7 and K-40. Be-7 and K-40 activity were also detected pre-operationally.

No other radionuclides were detected in broadleaf vegetation during the year. The ODCM required lower limits of detection were met and no unusual trends were noted. Plant-related activation, corrosion, or fission products were not detected during 2012 in broadleaf vegetation samples.

(4) Crop Samples Gamma analysis detected naturally occurring K-40 activity to be present in the samples collected from the indicator locations and in the sample collected from the control location.

K-40 activity was also detected during pre-operational crop monitoring.

K-40 was the only activity detected in the crop samples. The ODCM required lower limits of detection were met.

Plant-related activation, corrosion, or fission products were not detected during 2012 in crop samples and no unusual trends were noted.

E. Additional Samples Collected (not required by ODCM)

(1) Bottom Sediment Gamma analysis detected naturally occurring K-40 activity to be present in the samples collected from the indicator locations and in the samples collected from the control location.

K-40 activity was also detected during pre-operational bottom sediment monitoring.

Cs-137 activity was detected in nine out of the seventeen samples obtained from indicator locations (range 26 to 126 pCi/kg, dry). Cs-137 activity was also detected in both samples obtained from the control location (range 45 to 122pCi/kg, dry).

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 7 of 32

Cs-137 activity was detected in pre-operational samples. The Cs-137 activity detected in 2012 indicator bottom sediment samples was within the pre-operational range.

(Cs-137 activity detected in 1981 and 1982 was in the range of 79 to 953 pCi/kg. The decay corrected range of pre-operational Cs-1 37 activity detected is approximately 38 to 462 pCi/kg.)

The detected Cs-1 37 activity in the samples collected from the indicator locations was likely due to fallout since the measured activity is within the decay corrected range of pre-operational Cs-1 37 detected activity and Cs-1 37 activity has also been detected in samples collected at the control location.

Chart 7 plots the Cs-137 detected activity from the discharge cove indicator location and JRR control location bottom sediment samples. The detected Cs-137 activity measured from the discharge cove location reflects a decreasing trend. The Chart 7 trendline indicates Cs-137 activity detected at the JRR control location has also been decreasing. Chart 7 also displays that in recent years, the detected Cs-1 37 activity for the JRR and DC sample locations overlap.

Fe-55 activity was not detected in the fourteen samples obtained from indicator locations. No other radionuclides were detected in bottom sediment samples.

Plant-related activation, corrosion, or fission products were not detected in bottom sediment samples and no unusual trends were noted.

(2) Aquatic Vegetation Gamma analyses of aquatic vegetation samples obtained from indicator locations detected naturally occurring gamma emitters Be-7 and K-40. Be-7 and K-40 activity were also detected during pre-operational monitoring.

No other radionuclides were detected. Plant-related activation, corrosion, or fission products were not detected during 2012 in aquatic vegetation samples and no unusual trends were noted.

(3) Shoreline Sediment Naturally occurring K-40 activity was detected in the shoreline sediment samples obtained from the EEA and SC indicator locations.

K-40 activity was also detected during pre-operational monitoring.

Cs-137 activity (234.3 pCi/kg, dry) was detected in the shoreline sediment sample obtained from the EEA indicator location and in the sample obtained from the SC indicator location (75.8 pCi/kg, dry).

Cs-137 activity was also detected in pre-operational shoreline sediment samples.

Cs-137 activity detected in shoreline sediment samples collected from the DC location from 1982 to 1984 was in the range of 224 to 437 pCi/kg, dry. The decay corrected range of pre-operational Cs-137 activity detected is approximately 119 to 225 pCi/kg, dry. The detected Cs-137 activity in the shoreline sediment samples was likely due to fallout since the results are nearly within the pre-operational decay corrected range.

Additionally, Cs-137 activity is routinely detected in soil and sediment samples collected from the control locations.

No other radionuclides were detected.

Plant-related activation, corrosion, or fission products were not detected and no unusual trends were noted.

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 8 of 32

(4) Terrestrial Vegetation Naturally occurring Be-7 and K-40 activity were detected in a terrestrial vegetation indicator location sample collected in 2012.

No other radionuclides were detected.

Plant-related activation, corrosion or fission products were not detected during 2012 in terrestrial vegetation samples and no unusual trends were noted.

(5) Soil Naturally occurring K-40 activity was detected in the EEA indicator location soil sample. K-40 activity was also detected during pre-operational soil monitoring.

Cs-137 activity (155 pCi/kg) was detected in the EEA indicator location soil sample. Data was reviewed for soil samples collected pre-operationally. The detected Cs-137 activity range from February of 1985 was 255 to 2,160 pCi/kg, dry. The decay corrected range of pre-operational Cs-137 activity detected in soil is approximately 137 to 1,160 pCi/kg.

The detected Cs-137 activity in soil sampled in 2012 is within the decay corrected pre-operational range and is likely due to fallout.

Plant-related activation, corrosion, or fission products were not detected during 2012 in this soil sample and no unusual trends were noted.

(6) Deer Naturally occurring K-40 activity was detected in the deer sample obtained from the indicator location.

The deer sample was also analyzed for tritium. The detected tritium was 916 pCi/kg. The detected tritium activity was attributable to plant operation.

No other radionuclides were detected. No unusual trends were identified.

Ill. PROGRAM REVISIONS/CHANGES Based upon Condition Report 00051888, the descriptions of the air monitoring stations were revised in AP 07B-004, Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program), to be clearer.

For personnel safety reasons, dosimeter locations #4 and #51 were moved within the same sector.

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 9 of 32

IV. PROGRAM DEVIATIONS Drinking Water Samples Drinking water was not continuously collected at the Burlington control sample location during the 08-06-2012 to 09-04-2012 sample period due to an equipment malfunction (ruptured tube).

Approximately 2-1/2 gallons of water was collected before the sampler stopped operating. The composited sample and a grab sample were submitted to the vendor lab for analysis. The drinking water sampler was repaired on the same day of discovery. Condition Report 00056913 was generated to document the condition.

Drinking water was not continuously collected at the Iola indicator sample location during 09-28-2012 to 10-01-2012 since the sampler intake tubing was not moved following a water plant line-up change. Sufficient water was collected for the monthly composite sample. The drinking water sampler intake tubing was moved on the same day of discovery to a bay that contained water. Condition Report 00058066 was generated to document the condition.

Ground Water Protection The following information is being provided in association with the Nuclear Energy Institute (NEI) Groundwater Protection Industry Initiative:

Describe offsite ground water or surface water sample results that exceeded the REMP reporting criteria that were voluntarily communicated to State/Local officials during the calendar year - None.

V. INTERLABORATORY COMPARISON PROGRAM During 2012, Environmental, Inc., Midwest Laboratory was contracted to perform radiological analysis of environmental samples for WCNOC. The lab participated in the intercomparison studies administered by Environmental Resources Associates.

Appendix A is the Interlaboratory Comparison Program Results for Environmental, Inc., Midwest Laboratory.

Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also contained in Appendix A.

VI. COMPARISON TO THE RADIOACTIVE EFFLUENT RELEASE PROGRAM As described in the section discussing radioisotopes found in fish from Coffey County Lake, dose that may be received as a result of tritium released from WCGS is comparable with the theoretical doses calculated by the Radioactive Effluent Release Program.

The theoretical doses calculated by the Radioactive Effluent Release Program assume a person drinks the water from Coffey County Lake and eats the fish from Coffey County Lake.

Based upon these assumptions the dose to man from both pathways was calculated to be 0,194 mRem for 2012.

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 10 of 32

Using sample data obtained from the REMP, an adult drinking 2 liters per day of surface water from Coffey County Lake, using the average tritium activity (11,435 pCi/L), would receive a committed effective dose equivalent of 0.522 mRem per year. For an adult eating 21 kg of fish per year from Coffey County Lake, using the average tritium activity (7,728 pCi/kg), would receive a committed effective dose equivalent of 0.010 mRem per year. Based upon the REMP results, the dose from both pathways was calculated to be 0.532 mRem per year.

It should be noted Coffey County Lake is not used as a drinking water source. Calculating the dose to man for tritium detected in the Coffey County Lake surface water is for comparison purposes only.

The tritium dose values are being compared on a qualitative basis. It is not expected that the annual doses, as calculated in the Radioactive Effluent Release Report, would compare directly to those calculated from the REMP. The Radioactive Effluent Release Report provides a "snap shot" of potential dose resulting from the year's releases.

The REMP data indicates the accumulated result of releasing tritium into the lake since the start of plant operation.

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 11 of 32

TABLE I RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM DESCRIPTION (SAMPLE COLLECTION SPECIFIED BY ODCM)

EXPOSURE PATHWAY/

SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS (See Figures 1 & 5)

SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS AIRBORNE Radioiodine and Particulates Samples from six locations Continuous sampler operation with sample collection weekly, or more frequently if required, by dust loading.

Samples from locations near the site boundary in three sectors having the highest calculated annual average D/Q and one supplemental location (Locations 2, 18, 37 or 49 on Figure 1)

Analyze radioiodine canister weekly for 1-131 Analyze particulate filter weekly for gross beta activity; perform quarterly gamma isotopic analysis composite (by location)

Sample from the vicinity of a community having the highest calculated annual average D/Q (Location 32 on Figure 1, New Strawn)

Sample from a control location 9.5 to 18.5 miles distant in a low ranked D/Q sector (Location 53 on Figure 5) 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 12 of 32

TABLE I (Cont.)

EXPOSURE PATHWAY/

SAMPLE TYPE DIRECT RADIATION NUMBER OF SAMPLES AND SAMPLE LOCATIONS (See Figures 2 & 5) 40 routine monitoring stations with two or more dosimeters measuring dose continuously, placed as follows:

SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS Quarterly Gamma dose quarterly An inner ring of stations, one in each meteorological sector 0-3 mile range from the site (Locations 1, 7, 9, 11-13, 18, 26, 27, 29, 30, 37, 38, 46, 47, & 49 on Figure 2).

An outer ring of stations, one in each meteorological sector in the 3 to 5 mile range from the site (Locations 4, 5,15-17, 19, 22-25, 32, 34-36, 50 & 51 on Figure 2). Four sectors

[A, B, G & J] contain an additional station (Locations 2, 8, 14 &

20).

The balance of the stations to be placed in special interest areas such as population centers (Locations 23, 32 & 52), nearby residences 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 13 of 32

TABLE I (Cont.)

EXPOSURE PATHWAY/

SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS DIRECT RADIATION (cont.)

(I n

S E

C A

a c

n s

5 WATERBORNE

(

many locations are iear a residence),

chools (Locations 23 52), Environmental

-ducation Area (44),

.CL Public Fishing krea (46) and in two reas to serve as ontrol stations 10-20 niles distant from the ite (Locations 39 and 3 on Figure 5).

See Figure 3)

Surface Ground One sample upstream (Location JRR on Figure 3) and one sample downstream (Location SP on Figure 3).

Samples from one or two sources only if likely to be affected.

Monthly grab sample Quarterly grab sample Monthly gamma isotopic analysis and composite for tritium analysis quarterly Quarterly gamma isotopic analysis and tritium analysis Indicator samples at locations hydrologically down-gradient of the site (Locations C-10, C-49, F-1, G-2, J-1 and J-2 on Figure 3);

control sample at a location hydrologically upgradient of the site (Location B-12 on Figure 3).

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 14 of 32

TABLE I (Cont.)

EXPOSURE PATHWAY/

SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS WATERBORNE (cont.)

Drinking Shoreline Sediment Sample of municipal water supply at an indicator location downstream of the site (Location IO-DW on Figure 5); control sample from location upstream of the site (Location BW-15 on Figure 3).

One sample from the vicinity of Coffey County Lake discharge cove (Location DC on Figure 3); control sample from John Redmond Reservoir (Location JRR on Figure 3).

(See Figures 4 & 5)

Samples from milking animals at three indicator locations within 5 miles of the site having the highest dose potential (currently there are no locations producing milk for human consumption within 5 miles of the site); one sample from a control location greater than 10 miles from the site if indicator locations are sampled.

Monthly Composite Semiannually Monthly gamma isotopic analysis and gross beta analysis of composite sample. Quarterly tritium analysis of composites.

Semiannual gamma isotopic analysis INGESTION Milk Semimonthly April to November; monthly December-March Gamma isotopic analysis and 1-131 analysis of each sample 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 15 of 32

TABLE I (Cont.)

EXPOSURE PATHWAY/

SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS INGESTION (cont.)

Fish Broadleaf Vegetation Irrigated Crops Indicator samples of 1 to 3 recreationally important species from Coffey County Lake; control samples of similar species from John Redmond Reservoir spillway (Figure 4).

Samples of available broadleaf vegetation from two indicator locations (using the criteria from the "Land Use Census" section) with highest calculated annual average D/Q (Locations Q-6 and N-1 and alternate locations B-1, H-2 and R-2 on Figure 4); sample of similar broadleaf vegetation from a control location 9.5 to 18.5 miles distant in a low ranked D/Q sector (Location D-2 on Figure 5).

Sample of crops irrigated with water from the Neosho River downstream of the Neosho River - Wolf Creek confluence (locations will vary from year to year, e.g.,

Location NR-D1 and NR-D2 on Figure 5).

Semiannually Gamma isotopic analysis on edible portions Monthly when available At time of harvest Gamma isotopic analysis on edible portions Gamma isotopic analysis on edible portions 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 16 of 32

TABLE 2 SAMPLE LOCATION IDENTIFIERS, DISTANCES (Miles) AND DIRECTIONS (Sectors)

Sample Type Location Distance from Direction Sector Identifier Reactor Air Particulates and Radioiodine 2

2.7 N

A 18 3.0 SSE H

32 3.1 WNW P

37 2.0 NNW R

49 0.8 NNE B

53 10.8 ENE D

Dosimeters 1

1.4 N

A 2

2.7 N

A 4

4.0 NNE B

5 4.1 NE C

7 2.1 NE C

8 1.7 NNE B

9 2.0 ENE D

11 1.7 E

E 12 1.9 ESE F

13 1.6 SE G

14 2.5 SE G

15 4.6 ESE F

16 4.3 E

E 17 3.7 SE G

18 3.0 SSE H

19 3.9 SSE H

20 3.3 S

J 22 3.9 SSW K

23 4.3 SW L

24 4.1 WSW M

25 3.4 W

N 26 2.4 WSW M

27 2.2 SW L

29 2.7 SSW K

30 2.5 W

N 32 3.1 WNW P

34 4.4 NW Q

35 4.6 NNW R

36 4.2 N

A 37 2.0 NNW R

38 1.2 NW Q

39 13.1 N

A 41 0.8 NNW R

42 0.8 SSE H

43 0.7 WNW P

44 3.0 NNW R

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 17 of 32

TABLE 2 (Cont.)

SAMPLE LOCATION IDENTIFIERS, DISTANCES (Miles) AND DIRECTIONS (Sectors)

Sample Type Location Distance from Direction Sector Identifier Reactor Dosimeters 46 1.6 WNW P

47 0.16 S

J 49 0.8 NNE B

50 3.6 ENE D

51 4.3 S

J 52 3.6 SW L

53 10.8 ENE D

Surface Water JRR 3.7 W

N SP 3.2 SSE H

Ground Water B-12 1.9 NNE B

C-10 2.7 W

N C-49/L-49 2.8 SW L

F-1 2.5 ESE F

G-2 3.6 SE G

J-1 3.8 S

J J-2 4.3 S

J Drinking Water BW-15 3.9 SW L

1O-DW 26.1 SSE H

Shoreline Sediment DC 0.8 WNW P

EEA 3.0 NNW R

JRR 3.6 W

N SC 0.8 NNW R

Fish CCL 0.6 E to NNW E to R JRR 3.7 W

N Food/Garden B-1 0.8 NNE B

D-2 14.8 ENE D

H-2 3.0 SSE H

N-1 2.4 W

N Q-6 2.4 NW Q

Crops NR-D1 8.9 S

J NR-D2 11.5 S

J NR-U1 4.0 SSW K

Bottom Sediment DC 0.9 WNW P

EEA 3.0 NNW R

ESW 0.5 E

E JRR 3.7 W

N MUDS 1.5 WNW P

SC 0.8 NNW R

UHS 0.6 E

E Aquatic Vegetation DC ALT 1.5 NW Q

EEA 3.0 NNW R

MUDS 1.5 WNW P

SC 0.8 NNW R

MUDS 1.5 WNW P

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 18 of 32

TABLE 2 (Cont.)

SAMPLE LOCATION IDENTIFIERS, DISTANCES (Miles) AND DIRECTIONS (Sectors)

Sample Type Location Distance from Direction Sector Identifier Reactor

-Terrestrial Vegetation EEA 3.0 NNW R

Soil EEA 3.0 NNW R

Meat (Deer)

A1.5 1.5 N

A 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 19 of 32

TABLE 3 OSL Dosimeter Results mR/Standardized 90-day Quarter)

Location Qtr. 1 Qtr. 2 Qtr. 3 Qtr. 4 Total Annual (mR)

(mR)

(mR)

(mR)

Exposure (mR) 1 17.6 23.4 23.7 20.4 85.1 2

16.6 19.9 20.6 21.5 78.6 4

20.5 22.3 23.4 21.9 88.1 5

17.1 19.4 19.6 18.6 74.7 7

18.7 18.7 20.3 18.1 75.8 8

19.9 22.8 23.2 24.0 89.9 9

16.8 17.7 19.6 18.6 72.7 11 19.6 20.9 21.2 17.6 79.3 12 19.3 22.3 21.0 20.6 83.2 13 19.1 21.8 21.0 22.6 84.5 14 19.9 20.3 24.4 21.6 86.2 15 17.2 19.6 21.7 21.1 79.6 16 14.4 20.9 20.7 17.9 73.9 17 15.8 17.7 19.6 21.6 74.7 18 18.7 19.3 19.6 21.1 78.7 19 18.6 20.5 24.7 19.8 83.6 20 19.1 21.0 23.6 18.8 82.5 22 22.0 24.3 22.6 20.1 89.0 23 21.5 19.6 21.7 19.1 81.9 24 16.3 21.0 22.2 18.1 77.6 25 15.2 17.3 17.7 17.3 67.5 26 16.2 16.5 21.0 16.9 70.6 27 17.4 21.5 21.6 19.8 80.3 29 13.5 16.8 16.6 14.8 61.7 30 17.6 21.4 20.0 22.0 81.0 32 17.7 21.1 21.7 21.1 81.6 34 16.7 21.2 21.0 20.1 79.0 35 18.2 21.4 21.4 20.1 81.1 36 15.0 20.5 21.2 20.1 76.8 37 18.1 16.5 18.5 20.1 73.2 38 19.5 22.0 17.7 20.3 79.5 39 14.7 16.5 19.6 17.2 68.0 41 14.7 19.3 22.6 18.4 75.0 42 11.0 12.8 13.5 14.7 52.0 43 10.0 13.8 14.3 13.2 51.3 44 17.6 21.1 20.4 18.6 77.7 46 16.8 19.1 22.0 18.1 76.0 47 19.9 27.7 27.9 23.8 99.3 49 17.6 19.7 17.4 19.6 74.3 50 19.9 25.0 20.7 21.6 87.2 51 14.9 21.9 21.0 17.8 75.6 52 16.7 21.9 22.2 22.3 83.1 53 20.1 22.0 22.2 16.7 81.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 20 of 32

FIGURE 1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 21 of 32

FIGURE 2 DIRECT RADIATION PATHWAY SAMPLING LOCATIONS

FIGURE 3 WATERBORNE PATHWAY SAMPLING LOCATIONS

  • = DRINKING WATER N = GROUND WATER
  • = BOTTOM SEDIMENT A = SURFACE WATER
  • = SHORELINE SEDIMENT I

= AQUATIC VEGETATION 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 23 of 32

FIGURE 4 INGESTION PATHWAY SAMPLING LOCATIONS A = FISH (JRR)

I= BROADLEAF VEGETATION

  • = SOIL

-= FISH (CCL)

TERRESTRIAL VEGETATION

=DEER 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 24 of 32

FIGURE 5 A

  • = Dosimeter

CHART I 2012 Airborne Gross Beta Weekly Results

()

E

.2 CL 2

0 0l)

(.9 0.070 0.060 0.050 0.040 0.030 0.020 0.010 0.000 0

4 8

12 16 20 24 28 Week Number 32 36 40 44 48 52 m Location 2

  • Location 18

+ Location 32 A Location 37 M Location 49 ---

Location 53 (Control) 2012 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 26 of 32

CHART 2 0.060 a):E 0

0 E

C/

0.050 0.040 0.030 0.020 0.010 0

'1P 0

0 t~\\0 0

- - - Smoothed Avg. Indicator Locations Smoothed Avg. Control Location (40)

Smoothed Avg. Control Location (48)

-Smoothed Avg. Control Location (53) 2012 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 27 of 32

CHART 3 OSL Dosimeters - Indicator and Control Locations mR per Standardized 90-Day Quarter 24.0 22.0 20.0 18.0 16.0 14.0 12.0 10.0 8.0 6.0 4.0 Year/Quarter

- Indicator Locations Standardized 90-Day Quarter (mR)

Control Locations Standardized 90-Day Quarter (mR) 2012 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 28 of 32

CHART 4 Historical TLD Nearsite Locations and Control Locations 32.0 30.0 28.0 26.0 24.0 22.0 20.0 18.0 16.0 14.0 12.0 I 1980 1982 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 Avg. of Nearsite Locations

& Avg. of Control Locations

-Moving Avg. of Nearsite Locations (2 period) - - - Moving Avg. of Control Locations (2 period) 2012 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 29 of 32

CHART 5 Coffey County Lake Surface Water Tritium Data 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000

-L 0 ý-

1987 1992 1997 2002 2007 2012 S--*-- Yearly Average of Spillway Location -

Polynomial Trendline]

2012 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 30 of 32

CHART 6 Drinking Water Gross Beta (5 years) 6 5

co (D

4 3

2 1

NO N>

NN BW15 (Control)

-IODW (Indicator) 2012 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 31 of 32

CHART 7 Detected Cs-1 37 Activity in Bottom Sediment 1,000 900 800 700

_0 600 500 400 300 200 100 0

O C

CO CN O

I-M C(

V N

M 00 0

"0) 0"M

) 000 LO rN C M M. 0' 0

(O(N 0

(J 0()

0'-

N M

M,-

LO 0

0s (00)

(0 IT (00 LO 0)-M CO qT" LO N-N-CO CO 0)'

M 0-000)

C-0 0

0 0

0 CO 0) 0 0

0 0

-(

0 0

0 0

0 0

LO 04 M1 M, (01 W4 M4 M

M C-'-(0 0

0-LO O

(

C 0

(0 M

DC Cs-137 JRR Cs-137 -

Polynomial Trendline (DC)

Polynomial Trendline (JRR) 2012 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 32 of 32

-AT' Environmental, Inc.

Midwest Laboratory 700 Landwehr Road

  • Northbrook. IL 60062-2310 phone (847) 564-0700
  • fax (847) 564-4517 APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE:

Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only.

January, 2012 through December, 2012

Appendix A Interlaboratory Comparison Program Results Environmental, Inc., Midwest Laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.

Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

Results in Table A-1 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.

Table A-2 lists results for thermoluminescent dosimeters (TLDs), via International Intercomparison of Environmental Dosimeters, when available, and internal laboratory testing.

Table A-3 lists results of the analyses on in-house "spiked" samples for the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.

Table A-4 lists results of the analyses on in-house "blank" samples for the past twelve months. Data for previous years available upon request.

Table A-5 lists REMP specific analytical results from the in-house "duplicate" program for the past twelve months. Acceptance is based on the difference of the results being less than the sum of the errors.

Complete analytical data for duplicate analyses is available upon request.

The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program.

Results in Table A-7 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurement Laboratory Quality Assessment Program (EML).

Attachment A lists the laboratory precision at the 1 sigma level for various analyses. The acceptance criteria in Table A-3 is set at +/- 2 sigma.

Out-of-limit results are explained directly below the result.

Al

Attachment A ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSESa One standard deviation Analysis Level for single determination Gamma Emitters 5 to 100 pCi/liter or kg 5.0 pCi/liter

> 100 pCi/liter or kg 5% of known value Strontium-89b 5 to 50 pCi/liter or kg 5.0 pCi/liter

> 50 pCi/liter or kg 10% of known value Strontium-90b 2 to 30 pCi/liter or kg 5.0 pCi/liter

> 30 pCi/liter or kg 10% of known value Potassium-40

> 0.1 g/liter or kg 5% of known value Gross alpha

< 20 pCi/liter 5.0 pCi/liter

> 20 pCi/liter 25% of known value Gross beta 5 100 pCi/liter 5.0 pCi/liter

> 100 pCi/liter 5% of known value Tritium

_5 4,000 pCi/liter

+ lo =

169.85 x (known) 0,0 933

> 4,000 pCi/liter 10% of known value Radium-226,-228

-0.1 pCi/liter 15% of known value Plutonium

> 0.1 pCi/liter, gram, or sample 10% of known value Iodine-131, 5 55 pCi/liter 6 pCi/liter Iodine-129b

> 55 pCi/liter 10% of known value Uranium-238,

< 35 pCi/liter 6 pCi/liter Nickel-63b

> 35 pCi/liter 15% of known value Technetium-99b Iron-55b

.50 to 100 pCi/liter 10 pCi/liter

> 100 pCi/liter 10% of known value Other Analyses b 20% of known value a From EPA publication, "Environmental Radioactivity Laboratory Intercomparison Studies Program, Fiscal Year, 1981-1982, EPA-600/4-81-004.

b Laboratory limit.

A2

TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.

Concentration (pCi/L)

Lab Code Date Analysis Laboratory ERA Control Result b Result c Limits Acceptance ERW-1 783 04/09/12 Sr-89 ERW-1783 04/09/12 Sr-90 ERW-1786 ERW-1786 ERW-1 786 ERW-1786 ERW-1 786 04/09/12 04/09/12 04/09/12 04/09/12 04/09/12 Ba-133 Co-60 Cs-134 Cs-137 Zn-65 ERW-1789 04/09/12 Gr. Alpha ERW-1789 d 04/09/12 Gr. Beta ERW-1795 ERW-1795 ERW-1795 04/09/12 04/09/12 04/09/12 Ra-226 Ra-228 Uranium 62.2 +/- 6.0 33.7 +/- 2.1 75.7 +/- 4.1 71.9 +/- 4.0 70.0 +/- 4.3 151.5 +/- 6.1 108.3 +/- 89.0 55.0 +/- 2.4 76.2 +/- 1.8 6.4 +/- 0.4 5.4 +/- 1.2 56.2 +/- 2.6 16023 +/-355 41.5 +/- 4.1 19.7 +/- 1.6 82.7 +/- 4.4 77.2 +/- 3.7 74.4 +/- 1.5 183.0 +/- 6.2 211.0 +/-9.9 58.5 37.4 82.3 72.9 74.2 155.0 105.0 62.9 44.2 5.7 4.6 61.5 46.9 - 66.3 27.4 - 43.1 69.1 - 90.5 65.6 - 82.6 60.6 -81.6 140.0 - 172.0 94.5 - 125.0 33.0 - 78.0 29.6 -51.5 4.3 - 6.9 2.7 - 6.3 50.0 - 68.2 ERW-1798 04/09/12 H-3 ERW-6283 10/05/12 Sr-89 ERW-6283 10/05/12 Sr-90 15800 13800 -17400 Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Fail Pass ERW-6286 ERW-6286 ERW-6286 ERW-6286 ERW-6286 10/05/12 10/05/12 10/05/12 10/05/12 10/05/12 Ba-133 Co-60 Cs-134 Cs-1 37 Zn-65 39.1 20.1 84.8 78.3 76.6 183.0 204.0 58.6 39.2 24.8 15.0 4.6 62.5 29.7 - 46.1 14.4 - 23.8 71.3 -93.3 70.5 - 88.5 62.6 - 84.3 165.0 -203.0 184.0 - 240.0 30.6 - 72.9 26.0 - 46.7 20.6 - 29.4 11.2 -17.2 2.7 -6.2 50.8 - 69.3 ERW-6288 10/05/12 Gr. Alpha 47.0 +/- 2.3 ERW-6288 10/05/12 Gr. Beta 33.4 +/- 1.2 ERW-6290 10/05/12 1-131 ERW-6295e ERW-6295e ERW-6295 10/05/12 10/05/12 10/05/12 Ra-226 Ra-228 Uranium 23.3 +/- 1.0 17.5 +/-0.7 7.4 +/- 1.5 61.2 +/- 1.8 a Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing in drinking water conducted by Environmental Resources Associates (ERA).

b Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.

'Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.

d Sample dilution problem suspected. A new dilution was prepared and the sample reanalyzed.

Result of reanalysis, 38.3 +/- 1.3 pCi/L.

e Results of reanalyses (pCi/L): Ra-226, 16.51 +/- 0.73 Ra-228, 4.85 +/- 1.11. A new test was ordered from Environmental Resources Associates, results will be updated for first quarter, 2013.

Al-1

TABLE A-2. Thermoluminescent Dosimetry, (TLD, CaSO 4: Dy Cards).

mR Lab Code Date Known Lab Result Control Description Value

+/- 2 sigma Limits Acceptance Environmental, Inc.

2012-1 2012-1 2012-1 2012-1 2012-1 2012-1 2012-1 2012-1 2012-1 2012-1 2012-1 2012-1 2/7/2012 2/712012 2/7/2012 2/7/2012 2/7/2012 2/7/2012 2/7/2012 2/7/2012 2/7/2012 2/7/2012 2/7/2012 2/7/2012 30 cm.

74.87 40 cm.

50 cm.

70 cm.

75 cm.

80 cm.

90 cm.

100 cm.

110 cm.

120 cm.

150 cm.

180 cm.

40 cm.

50 cm, 60 cm.

70 cm.

80 cm.

90 cm, 100 cm.

110 cm.

120 cm.

150 cm.

180 cm.

42.12 26.95 13.75 11.98 10.53 8.32 6.74 5.57 4.68 2.99 2.08 33.75 21.6 15 11.02 8.44 6.67 5.4 4.46 3.75 2.4 1.67 87.22 +/- 2.86 53.70 +/- 4.53 33.04 +/- 1.96 13.26 +/- 1.15 13.38 +/- 1.68 11.27 +/- 0.95 7.79 +/- 0.83 5.91 +/- 0.25 4.63 +/- 0.83 3.96 +/- 1.68 2.41 +/- 0.08 2.02 +/- 0.25 43.74 +/- 1.31 25.37 +/- 0.82 16.63 +/- 0.45 10.58 +/- 0.20 8.55 +/- 1.18 5.75 +/- 0.33 4.44 +/- 0.22 3.85 +/- 0.05 3.03 +/- 0.71 1.82 +/- 0.10 1.19 +/- 0.34 52.41 - 97.33 29.48 - 54.76 18.87 - 35.04 9.63 - 17.88 8.39 - 15.57 7.37 - 13.69 5.82 - 10.82 4.72 - 8.76 3.90 - 7.24 3.28 - 6.08 2.09 - 3.89 1.46 -2.70 23.63 - 43.88 15.12 -28.08 10.50 - 19.50 7.71 - 14.33 5.91 - 10.97 4.67 - 8.67 3.78 - 7.02 3.12 -5.80 2.63 - 4.88 1.68-3.12 1.17 -2.17 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Environmental, Inc.

2012-2 2012-2 2012-2 2012-2 2012-2 2012-2 2012-2 2012-2 2012-2 2012-2 2012-2 9/11/2012 9/11/2012 9/11/2012 9/11/2012 9/11/2012 9/11/2012 9/11/2012 9/11/2012 9/11/2012 9/11/2012 9/11/2012 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A2-1

TABLE A-3. In-House "Spiked" Samples Concentration (pCi/L)a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 c Activity Limits d Acceptance SPW-41824 W-22712 W-22712 SPAP-1032 SPAP-1032 SPAP-1034 SPW-1036 SPW-1036 SPW-1036 SPMI-1038 SPMI-1038 SPW-1045 SPW-1047 SPW-1049 W-31412 SPW-1520 SPW-41825 WW-1547 WW-1547 WW-1547 W-51712 W-61112 W-61112 SPAP-4418 SPAP-4420 SPAP-4420 SPMI-4422 SPMI-4422 SPMI-4422 SPMI-4422 SPW-4424 SPW-4424 SPW-4424 SPF-4426 SPF-4426 SPW-4428 SPW-4430 SPW-4432 W-81712 SPW-5407 SPW-18022 2/15/2012 2/27/2012 2/27/2012 3/5/2012 3/5/2012 3/5/2012 3/5/2012 3/5/2012 3/5/2012 3/5/2012 3/5/2012 3/5/2012 3/5/2012 3/5/2012 3/14/2012 3/23/2012 4/10/2012 4/16/2012 4/16/2012 4/16/2012 5/17/2012 6/11/2012 6/11/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 7/25/2012 8/17/2012 8/29/2012 9/10/2012 Ra-228 Gr. Alpha Gr. Alpha Cs-134 Cs-137 Gr. Beta Cs-134 Cs-137 Sr-90 Cs-1 34 Cs-137 H-3 Ni-63 C-14 Ra-226 U-238 Ra-228 Ba-133 Cs-134 Cs-137 Ra-226 Gr. Alpha Gr. Beta Gr. Beta Cs-134 Cs-137 Co-60 Cs-134 Cs-137 Sr-90 Co-60 Cs-137 Sr-90 Cs-134 Cs-137 C-14 H-3 Ni-63 Ra-226 U-238 Ra-228 24.85 +/- 2.14 14.59 +/- 0.34 43.57 +/- 0.40 7.06 +/- 1.71 102.63 +/- 3.13 44.30 +/- 0.11 43.23 +/- 3.84 57.44 +/- 4.60 60.51 +/- 1.93 37.79 +/- 4.06 54.75 +/- 5.09 68022 +/- 746 217.10 +/- 3.64 3858.90 +/- 12.79 13.13 +/- 0.36 45.67 +/- 2.02 28.48 +/- 2.51 18.99 +/- 4.67 9.28 +/- 2.82 27.77 +/- 4.49 17.29 +/- 0.43 22.16 +/- 0.45 43.57 +/- 0.40 43.74 +/- 0.11 4.54 +/- 0.73 104.70 +/- 2.77 31.43 +/- 2.12 16.50 +/- 1.17 29.60 +/- 2.61 31.60 +/- 1.35 38.52 +/- 1.76 33.23 +/- 2.27 36.56 +/- 1.58 947.50 +/- 42.50 2692.00 +/- 62.40 4325.70 +/- 15.80 70119.40 +/- 773.40 187.20 +/- 3.85 14.94 +/- 0.40 42.95 +/- 0.11 29.03 +/- 2.80 28.75 20.00 41.70 5.26 104.24 46.88 39.42 52.12 61.52 39.42 52.12 69048 206.64 4738.80 16.70 41.70 28.35 26.70 8.68 29.70 16.70 20.00 45.20 46.50 4.60 103.30 31.62 16.15 26.64 30.47 37.95 32.01 40.60 1025.00 2480.00 4738.80 67570.00 206.80 16.70 41.70 28.21 20.13 - 37.38 10.00 - 30.00 20.85 - 62.55 0.00 - 15.26 93.82 - 114.66 28.13 - 65.63 29.42 - 49.42 42.12 -62.12 49.22 - 73.82 29.42 - 49.42 42.12 - 62.12 55238 - 82858 144.65 -268.63 2843.28 - 6634.32 11.69 -21.71 29.19 -54.21 19.85 - 36.86 16.70 - 36.70 0.00 - 18.68 19.70 - 39.70 11.69 -21.71 10.00 - 30.00 35.20 - 55.20 27.90 -65.10 2.76 - 6.44 92.97 - 113.63 21.62 -41.62 6.15 -26.15 16.64 - 36.64 24.38 - 36.56 27.95 - 47.95 22.01 - 42.01 32.48 - 48.72 922.50 - 1127.50 2232.00 - 2728.00 2843.28 - 6634.32 54056.00 - 81084.00 144.76 - 268.84 11.69 -21.71 29.19 -54.21 19.75 - 36.67 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A3-1

TABLE A-3. In-House "Spiked" Samples Concentration (pCi/L)a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 c Activity Limitsd Acceptance W-91012 W-91012 9/10/2012 Gr. Alpha 9/10/2012 Gr. Beta W-100312 W-100312 W-101812 ESO-7235 SPW-7753 SPW-18023 10/3/2012 10/3/2012 10/18/2012 12/6/2012 12/6/2012 12/18/2012 Gr. Alpha Gr. Beta Ra-226 Sr-90 U-238 Ra-228 19.95 +/- 0.42 43.47 +/- 0.40 19.95 +/- 0.41 44.21 +/- 0.40 18.80 +/- 0.43 138.79 +/- 2.67 45.55 +/- 5.05 31.59 +/- 2.99 20.00 45.20 20.00 45.20 16.70 161.05 41.70 25.98 10.00 -30.00 35.20 - 55.20 10.00 -30.00 35.20 - 55.20 11.69 -21.71 128.84 - 193.26 29.19 -54.21 18.19 -33.77 Pass Pass Pass Pass Pass Pass Pass Pass 8 Liquid sample results are reported in pCi/Liter, air filters( pCi/filter), charcoal (pCi/mr3), and solid samples (pCi/g).

Laboratory codes : W (Water), MI (milk), AP (air filter), SO (soil), VE (vegetation), CH (charcoal canister), F (fish), U (urine).

C Results are based on single determinations.

d Control limits are established from the precision values listed in Attachment A of this report, adjusted to +/- 2(T.

NOTE: For fish, Jello is used for the Spike matrix. For Vegetation, cabbage is used for the Spike matrix.

A3-2

TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysisb Laboratory results (4.66a)

Acceptance Type LLD Activityc Criteria (4.66 a)

SPW-41814 Water 2/15/2012 Ra-228 0.65 0.49 +/- 0.36 2

W-22712 Water 2/27/2012 Gr. Alpha 0.42

-0.04 +/- 0.29 1

W-22712 Water 2/27/2012 Gr. Beta 0.74

-0.54 +/- 0.50 3.2 SPAP-1031 Air Filter 3/5/2012 Cs-134 1.89 100 SPAP-1031 Air Filter 3/5/2012 Cs-137 1.16 100 SPAP-1033 Air Filter 3/5/2012 Gr. Beta 0.003 0.013 +/- 0.003 0.01 SPW-1035 Water 3/5/2012 Cs-134 2.40 10 SPW-1035 Water 3/5/2012 Cs-137 2.88 10 SPW-1035 Water 3/5/2012 1-131(G) 2.35 20 SPW-1035 Water 3/5/2012 Sr-90 0.60

-0.11 +/- 0.26 1

SPMI-1037 Milk 3/5/2012 Cs-134 2.85 10 SPMI-1037 Milk 3/5/2012 Cs-137 3.73 10 SPMI-1037 Milk 3/5/2012 1-131(G) 3.24 20 SPW-1044 Water 3/5/2012 H-3 146.10 37.10 +/- 74.40 200 SPW-1046 Water 3/5/2012 Ni-63 19.07 8.30 +/- 11.79 20 SPW-1048 Water 3/5/2012 C-14 5.70 2.99 +/- 3.04 200 SPW-1166 water 3/9/2012 C-14 6.79 1.11 200 W-31412 Water 3/14/2012 Ra-226 0.034 0.043 +/- 0.027 1

SPW-1521 Water 3/23/2012 U-238 0.10 0.09 +/- 0.11 1

W-51712 Water 4/24/2012 Ra-226 0.04 0.04 +/- 0.03 1

W-61112 Water 6/11/2012 Gr. Alpha 0.47

-0.14 +/- 0.32 1

W-61112 Water 6/11/2012 Gr. Beta 0.71 0.29 +/- 0.51 3.2 SPW-41815 Water 7/7/2011 Ra-228 0.77 0.52 +/- 0.42 2

SPAP-4417 Air Filter 7/25/2012 Gr. Beta 0.001 0.021 +/- 0.003 0.01 SPMI-4421 Milk 7/25/2012 Co-60 4.29 10 SPMI-4421 Milk 7/25/2012 Cs-134 3.58 10 SPMI-4421 Milk 7/25/2012 Cs-137 4.60 10 SPMI-4421 Milk 7/25/2012 Sr-90 0.45 0.53 +/- 0.27 1

SPW-4423 Water 7/25/2012 Co-60 1.88 10 SPW-4423 Water 7/25/2012 Cs-134 2.38 10 SPW-4423 Water 7/25/2012 Cs-137 2.80 10 SPW-4423 water 7/25/2012 Sr-90 0.45 0.08 +/- 0.22 1

SPF-4425 Fish 7/25/2012 Co-60 6.74 100 SPF-4425 Fish 7/25/2012 Cs-134 7.47 100 SPF-4425 Fish 7/25/2012 Cs-137 9.62 100 SPW-4427 Water 7/25/2012 C-14 10.93 3.54 +/- 5.84 200 SPW-4431 Water 7/25/2012 Ni-63 19.00 5.50 +/- 11.70 20 W-81712 Water 8/17/2012 Ra-226 0.038 0.035 +/- 0.030 1

SPW-5408 Water 8/29/2012 U-238 0.039 0.015 +/- 0.057 1

A4-1

TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysiso Laboratory results (4.66a)

Acceptance Type LLD Activityc Criteria (4.66 a)

SPW-18032 W-91012 W-91012 W-100312 W-100312 W-101812 SPW-7754 SPW-18033 Water Water Water Water Water Water Water Water 9/10/2012 9/10/2012 9/10/2012 10/3/2012 10/3/2012 10/18/2012 12/6/2012 12/18/2012 Ra-228 Gr. Alpha Gr. Beta Gr. Beta Gr. Beta Ra-226 U-238 Ra-228 0.78 0.42 0.75 0.77 0.43 0.04 0.10 0.98 0.85 +/- 0.46 0.027 +/- 0.29

-0.13 +/- 0.52

-0.32 +/- 0.53 0.06 +/- 0.30 0.04 +/- 0.03 0.02 +/- 0.08 0.43 +/- 0.50 2

1 3.2 3.2 3.2 1

1 2

a Liquid sample results are reported in pCi/Liter, air filters( pCi/filter), charcoal (pCi/charcoal canister), and solid samples (pCi/kg).

1-131(G); iodine-1 31 as analyzed by gamma spectroscopy.

c Activity reported is a net activity result. For gamma spectroscopic analysis, activity detected below the LLD value is not reported.

A4-2

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance CF-20, 21 CF-20, 21 CF-20, 21 P-9133, 9134 U-302, 303 S-386, 387 S-386, 387 S-386, 387 S-386, 387 S-386,387 WW-619, 620 MI-702, 703 WW-892, 893 S-850,851 S-850,851 W-1251, 1252 W-1251, 1252 W-1251, 1252 W-1251, 1252 AP-1209, 1210 XWW-1564, 1565 SG-1438, 1439 SG-1438, 1439 WW-1585, 1586 AP-2103, 2104 AP-2166, 2167 AP-1632, 1633 E-1653, 1654 E-1653, 1654 SG-1677, 1678 SG-1677, 1678 SWU-1719, 1720 W-1698, 1699 W-1698, 1699 W-1698, 1699 SG-1761, 1762 SG-1761, 1762 AP-2019, 2020 DW-2272, 2273 DW-2356, 2357 1/3/2012 1/3/2012 1/3/2012 1/3/2012 1/17/2012 1/23/2012 1/23/2012 1/23/2012 1/23/2012 1/23/2012 1/31/2012 2/6/2012 2/17/2012 2/22/2012 2/22/2012 3/6/2012 3/6/2012 3/6/2012 3/6/2012 3/8/2012 3/14/2012 3/19/2012 3/19/2012 3/19/2012 3/28/2012 3/28/2012 3/29/2012 4/2/2012 4/2/2012 4/2/2012 4/2/2012 4/3/2012 4/5/2012 4/5/2012 4/5/2012 4/10/2012 4/10/2012 4/12/2012 4/20/2012 4/24/2012 Gr. Beta K-40 Sr-90 H-3 Beta (-K40)

Ac-228 Bi-214 Pb-214 TI-208 U-235 H-3 K-40 Gr. Beta Cs-134 Cs-137 Gr. Alpha Gr. Beta H-3 Tc-99 Be-7 H-3 Ac-228 Pb-214 H-3 Be-7 Be-7 Be-7 14.50 +/- 0.29 12.88 +/- 0.55 0.01 +/- 0.01 108.86 +/- 83.03 6.84 +/- 2.91 0.77 +/- 0.11 0.80 +/- 0.07 0.74 +/- 0.06 0.21 +/- 0.02 0.05 +/- 0.02 257.20 +/- 86.00 1337.00 +/- 123.00 3.46 +/- 0.56 0.14 +/- 0.02 0.21 +/- 0.03 1.20 +/- 0.62 16.86 +/- 1.43 5235.52 +/- 230.91 19.67 +/- 3.60 0.24 +/- 0.12 308.00 +/- 88.00 6.01 +/- 0.30 4.69 +/- 0.49 3124.50 +/- 176.96 0.080 +/- 0.016 0.061 +/- 0.020 0.26 +/- 0.12 15.02 +/- 0.30 12.40 +/- 0.53 0.01 +/- 0.01 206.60 +/- 86.38 5.24 +/- 2.56 0.79 +/- 0.14 0.73 +/- 0.11 0.75 +/- 0.11 0.21 +/- 0.04 0.12 +/- 0.05 305.80 +/- 88.30 1460.40 +/- 102.00 3.77 +/- 0.59 0.13 +/- 0.02 0.22 +/- 0.03 1.27 +/- 0.92 15.14 +/- 1.34 4893.24 +/- 224.55 14.46 +/- 3.51 0.20 +/- 0.11 293.00 +/- 87.00 6.23 +/- 0.31 5.20 +/- 0.54 2982.38 +/- 173.62 0.076 +/- 0.013 0.071 +/- 0.016 0.24 +/- 0.12 14.76 +/- 0.21 12.64 +/- 0.38 0.01 +/- 0.00 157.73 +/- 59.91 6.04 +/- 1.94 0.78 +/- 0.09 0.77 +/- 0.07 0.75 +/- 0.06 0.21 +/- 0.02 0.09 +/- 0.03 281.50 +/- 61.63 1398.70 +/- 79.90 3.61 +/- 0.41 0.14 0.22 1.24 16.00 5064.38 17.07 0.22 300.50 6.12 4.95 3053.44 0.078 0.066 0.25

+/- 0.01

+/- 0.02

+/- 0.55

+/- 0.98

+/- 161.05

+/- 2.51

+/- 0.08

+/- 61.87

+/- 0.22

+/- 0.36

+/- 123.96

+/- 0.010

+/- 0.013

+/- 0.08 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Gr. Beta K-40 Ac-228 Pb-214 Gr. Beta Gr. Beta Ra-226 Ra-228 Ac-228 Pb-214 Be-7 1-131 Gr. Beta 1.53 +/- 0.05 1.34 +/- 0.13 6.63 +/- 0.37 4.77 +/- 0.16 1.16 +/- 0.41 10.86 +/- 1.49 0.41 +/- 0.15 1.46 +/- 0.76 16.26 +/- 0.53 14.16 +/- 1.44 0.17 +/- 0.10 0.52 +/- 0.24 12.82 +/- 2.01 1.55 +/- 0.04 1.36 +/- 0.14 6.49 +/- 0.33 5.07 +/- 0.14 1.53 +/- 0.44 9.42 +/- 1.32 0.67 +/- 0.18 1.48 +/- 0.74 16.55 +/- 0.44 15.40 +/- 1.56 0.17 +/- 0.08 0.49 +/- 0.27 9.47 +/- 1.74 1.54 +/- 0.03 1.35 +/- 0.10 6.56 +/- 0.25 4.92 +/- 0.11 1.35 +/- 0.30 10.14 +/- 1.00 0.54 +/- 0.12 1.47 +/- 0.53 16.41 +/- 0.34 14.78 +/- 1.06 0.17 +/- 0.07 0.51 +/- 0.18 11.14 +/- 1.33 A5-1

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance G-2403, 2404 G-2403, 2404 BS-2445, 2446 BS-2445, 2446 SWU-2550, 2551 WW-2614, 2615 WW-2614, 2615 BS-2656, 2657 BS-2656, 2657 SO-2635, 2636 SO-2635, 2636 MI-2677, 2678 VE-2719, 2720 SWU-3221, 3222 SWU-3221, 3222 WW-3073, 3074 AP-2968, 2969 F-3031, 3032 F-3031, 3032 G-3094, 3095 F-3412, 3413 F-3412, 3413 MI-3067, 3068 SO-3305, 3306 SO-3305, 3306 SO-3305, 3306 LW-3454, 3455 BS-3697, 3698 BS-3697, 3698 BS-3697, 3698 VE-3798, 3799 WW-4790, 4791 DW-30103, 30104 DW-30103, 30104 LW-3970, 3971 DW-3949, 3950 SG-4075, 4076 SG-4075, 4076 SG-4075, 4076 AP-4390, 4391 AP-4390, 4391 AP-4012, 4013 SW-4033, 4034 5/1/2012 5/1/2012 5/1/2012 5/1/2012 5/1/2012 5/1/2012 5/1/2012 5/2/2012 5/2/2012 5/3/2012 5/3/2012 5/7/2012 5/7/2012 5/8/2012 5/8/2012 5/14/2012 5/17/2012 5/22/2012 5/22/2012 5/23/2012 5/23/2012 5/23/2012 5/24/2012 5/30/2012 5/30/2012 5/30/2012 5/31/2012 6/14/2012 6/14/2012 6/14/2012 6/20/2012 6/20/2012 6/27/2012 6/27/2012 6/28/2012 6/29/2012 7/2/2012 7/2/2012 7/2/2012 7/3/2012 7/3/2012 7/5/2012 7/5/2012 Be-7 K-40 Gr. Beta K-40 Gr. Beta Gr. Beta H-3 Cs-137 K-40 Cs-137 K-40 K-40 K-40 Gr. Beta H-3 H-3 Be-7 H-3 K-40 Gr. Beta Gr. Beta K-40 K-40 Cs-137 Gr. Beta TI-208 Gr. Beta Be-7 Cs-1 37 K-40 K-40 H-3 Ra-226 Ra-228 Gr. Beta 1-131 Ac-228 K-40 Pb-214 Be-7 Be-7 Be-7 H-3 1.77 +/- 0.21 6.38 +/- 0.50 8.92 +/- 1.52 5.86 +/- 0.38 2.07 +/- 0.65 2.03 +/- 1.04 750.60 +/- 106.20 0.13 +/- 0.07 10.15 +/- 0.97 0.046 +/- 0.024 13.20 +/- 0.74 1415.30 +/- 131.40 4.15 +/- 0.36 1.67 +/- 0.47 236.90 +/- 101.90 339.12 +/- 145.45 0.25 +/- 0.12 11291.00 +/- 372.80 3528.90 +/- 372.80 7.89 +/- 0.16 3.46 +/- 0.10 2.40 +/- 0.38 1267.20 +/- 105.00 0.024 +/- 0.013 10.95 +/- 0.89 0.068 +/- 0.018 2.12 +/- 0.86 2.05 +/- 0.19 2.32 +/- 0.39 6.67 +/- 0.28 5.93 +/- 0.38 251.33 +/- 86.51 0.30 +/- 0.08 0.76 +/- 0.54 1.49 +/- 1.06 0.54 +/- 0.26 0.33 +/- 0.09 6.71 +/- 0.58 0.46 +/- 0.05 0.09 +/- 0.02 0.11 +/- 0.02 0.27 +/- 0.09 614.99 +/- 107.99 1.55 +/- 0.33 6.93 +/- 0.72 9.29 +/- 1.63 6.22 +/- 0.48 1.59 +/- 0.62 2.36 +/- 1.14 653.20 +/- 102.30 0.07 +/- 0.04 11.13 +/- 0.90 0.050 +/- 0.027 14.01 +/- 0.67 1348.10 +/- 109.00 4.19 +/- 0.38 1.39 +/- 0.45 281.90 +/- 103.70 337.23 +/- 98.19 0.21 +/- 0.09 11167.00 +/- 315.00 3677.20 +/- 392.40 8.01 +/- 0.16 3.33 +/- 0.10 2.55 +/- 0.43 1305.70 +/- 109.80 0.030 +/- 0.015 10.86 +/- 0.89 0.062 +/- 0.017 2.27 +/- 0.77 2.27 +/- 0.38 2.26 +/- 0.66 6.64 +/- 0.42 6.03 +/- 0.37 372.48 +/- 92.27 0.42 +/- 0.09 0.78 +/- 0.54 0.72 +/- 0.53 0.25 +/- 0.26 0.34 +/- 0.06 7.20 +/- 0.32 0.49 +/- 0.03 0.09 +/- 0.01 0.10 +/- 0.01 0.29 +/- 0.16 512.31 +/- 103.83 1.66 +/- 0.20 6.66 +/- 0.44 9.11 +/- 1.11 6.04 +/- 0.31 1.83 +/- 0.45 2.20 +/- 0.77 701.90 +/- 73.73 0.10 +/- 0.04 10.64 +/- 0.66 0.048 +/- 0.018 13.61 +/- 0.50 1381.70 +/- 85.36 4.17 +/- 0.26 1.53 +/- 0.33 259.40 +/- 72.69 338.18 +/- 87.74 0.23 +/- 0.07 11229.00 +/- 244.03 3603.05 +/- 270.63 7.95 +/- 0.11 3.40 +/- 0.07 2.48 +/- 0.29 1286.45 +/-75.96 0.027 +/- 0.010 10.91 +/- 0.63 0.065 +/- 0.012 2.20 +/- 0.58 2.16 +/- 0.21 2.29 +/- 0.38 6.66 +/- 0.25 5.98 +/- 0.26 311.90 +/- 63.24 0.36 +/- 0.06 0.77 +/- 0.38 1.11 +/- 0.59 0.40 +/- 0.18 0.34 +/- 0.05 6.96 +/- 0.33 0.48 +/- 0.03 0.09 +/- 0.01 0.11 +/- 0.01 0.28 +/- 0.09 563.65 +/- 74.91 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-2

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance VE-4054, 4055 VE-4222, 4223 VE-4222, 4223 DW-30113, 30114 DW-30115, 30116 DW-30124, 30125 DW-30124, 30125 DW-30126, 30127 AP-4433, 4434 SG-4475, 4476 SG-4475, 4476 WW-4685, 4686 AP-4706, 4707 SO-4748, 4749 SO-4748, 4749 SO-4748, 4749 SO-4748, 4749 VE-4832, 4833 DW-30149, 30150 DW-30149, 30150 SG-4916, 4917 SG-4916, 4917 F-5313, 5314 F-5313, 5314 F-5313, 5314 VE-5166, 5167 VE-5376, 5377 VE-5334, 5335 VE-5481, 5482 VE-5481, 5482 VE-5481, 5482 DW-30164, 30165 DW-30164, 30165 VE-5166, 5167 ME-5607, 5608 ME-5607, 5608 SW-5901, 5902 BS-6048, 6049 AP-6482, 6483 7/9/2012 7/13/2012 7/13/2012 7/13/2012 7/13/2012 7/13/2012 7/13/2012 7/13/2012 7/19/2012 7/19/2012 7/19/2012 7/24/2012 7/26/2012 7/26/2012 7/26/2012 7/26/2012 7/26/2012 8/1/2012 8/1/2012 8/1/2012 8/3/2012 8/3/2012 8/9/2012 8/9/2012 8/9/2012 8/15/2012 8/22/2012 8/27/2012 8/28/2012 8/28/2012 8/28/2012 8/30/2012 8/30/2012 9/4/2012 9/4/2012 9/4/2012 9/17/2012 9/24/2012 9/27/2012 K-40 Be-7 K-40 Ra-228 Gr. Alpha Ra-226 Ra-228 Gr. Alpha Be-7 Gr. Alpha Gr. Beta H-3 Be-7 Gr. Beta Gr. Beta U-233/4 U-238 K-40 Ra-226 Ra-228 Ac-228 K-40 Cs-1 37 Gr. Beta K-40 K-40 Gr. Beta K-40 Be-7 K-40 Sr-90 Ra-226 Ra-228 K-40 Gr. Beta K-40 H-3 K-40 Be-7 7.28 t 0.56 0.16 +/- 0.08 7.20 +/- 0.30 1.93 +/- 0.66 7.46 +/- 1.21 1.16 +/- 0.15 1.38 +/- 0.56 6.23 +/- 1.16 0.17 +/- 0.09 17.03 +/- 4.17 13.23 +/- 2.61 289.00 +/- 99.00 0.28 +/- 0.14 20.45 +/- 1.04 20.45 +/- 1.04 0.11 +/-0.02 0.12 +/- 0.02 4.06 +/- 0.22 2.69 +/- 0.22 2.77 +/- 0.75 11.03 +/- 0.33 6.39 +/- 0.80 0.05 +/- 0.02 4.12 +/- 0.08 3.07 +/- 0.42 4.26 +/- 0.28 7.72 +/- 0.17 1.65 +/- 0.17 2.52 +/- 0.19 5.05 +/- 0.37 0.01 +/- 0.00 1.33 +/- 0.15 2.76 +/- 0.66 2.05 1 0.32 2.92 +/- 0.08 2.06 +/- 0.32 10909.00 +/- 311.00 1.24 +/- 0.20 0.09 +/- 0.02 7.42 +/- 0.63 0.22 +/- 0.09 6.60 +/- 0.30 1.03 +/- 0.53 7.02 +/- 1.14 0.90 +/- 0.12 1.72 +/- 0.60 6.75 +/- 1.29 0.21 +/- 0.10 15.56 +/- 3.96 14.36 +/- 2.47 375.00 +/- 103.00 0.24 +/- 0.14 19.22 +/- 0.94 19.22 +/- 0.94 0.10 +/- 0.01 0.11 +/- 0.01 4.08 +/- 0.24 2.79 +/- 0.22 1.61 +/- 0.57 11.08 +/- 0.44 6.98 +/- 0.88 0.05 +/- 0.02 4.10 +/- 0.08 3.14 +/- 0.40 3.66 +/- 0.47 7.61 +/- 0.16 1.72 +/- 0.15 2.65 +/- 0.21 4.79 +/- 0.39 0.01 +/- 0.01 1.59 +/- 0.17 1.54 +/- 0.56 2.53 +/- 0.36 2.89 +/- 0.08 2.53 +/- 0.36 10817.00 +/- 310.00 1.18 +/- 0.21 0.09 +/- 0.03 7.35 +/- 0.42 0.19 +/- 0.06 6.90 +/- 0.21 1.48 +/- 0.42 7.24 +/- 0.83 1.03 +/- 0.10 1.55 +/- 0.41 6.49 +/- 0.87 0.19 +/- 0.07 16.30 +/- 2.88 13.80 +/- 1.80 332.00 +/- 71.43 0.26 +/- 0.10 19.84 +/- 0.70 19.84 +/- 0.70 0.11 +/- 0.01 0.12 +/- 0.01 4.07 +/- 0.16 2.74 +/- 0.16 2.19 +/- 0.47 11.06 +/- 0.28 6.69 +/- 0.59 0.05 +/- 0.01 4.11 +/- 0.06 3.11 +/- 0.29 3.96 +/- 0.27 7.67 +/- 0.12 1.68 +/- 0.12 2.59 +/- 0.14 4.92 +/- 0.27 0.01 +/- 0.00 1.46 +/- 0.11 2.15 +/- 0.43 2.29 +/- 0.24 2.90 +/- 0.06 2.29 +/- 0.24 10863.00 +/- 219.56 1.21 +/- 0.14 0.09 +/- 0.02 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-3

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance G-6090,6091 G-6090,6091 G-6090,6091 SO-6111, 6112 SO-6111, 6112 W-6795,6796 AP-6461, 6462 WW-6279,6280 W-6346,6347 VE-6503, 6504 WW-6606, 6607 WW-6606,6607 WW-7237,7238 F-6627, 6628 VE-6669, 6670 VE-6669, 6670 SS-6711, 6712 SS-6711, 6712 SS-6711, 6712 SS-6711, 6712 SS-6711, 6712 WW-7258, 7259 WW-7655, 7656 WW-7747,7748 MI-6963, 6964 MI-7174, 7175 SG-7221, 7222 DW-30216, 30217 DW-30216, 30217 DW-30216, 30217 MI-7363, 7364 CF-7384, 7385 VE-7489, 7490 AP-7531, 7532 BS-7573, 7574 LW-7865, 7866 SG-8095,8096 SG-8095,8096 10/1/2012 10/1/2012 10/1/2012 10/1/2012 10/1/2012 10/1/2012 10/2/2012 10/3/2012 10/3/2012 10/9/2012 10/10/2012 10/10/2012 10/12/2012 10/15/2012 10/16/2012 10/16/2012 10/16/2012 10/16/2012 10/16/2012 10/16/2012 10/16/2012 10/22/2012 10/25/2012 10/25/2012 10/28/2012 11/5/2012 11/9/2012 11/9/2012 11/9/2012 11/9/2012 11/13/2012 11/13/2012 11/16/2012 11/21/2012 11/24/2012 12/5/2012 12/19/2012 12/19/2012 Be-7 Gr. Beta K-40 Cs-137 K-40 H-3 Be-7 Gr. Beta Ra-226 K-40 Gr. Beta H-3 H-3 K-40 Be-7 K-40 Ac-228 Bi-214 Gr. Beta Pb-212 TI-208 H-3 H-3 H-3 K-40 K-40 Pb-214 Gr. Alpha Ra-226 Ra-228 K-40 K-40 K-40 Be-7 K-40 Gr. Beta Ac-228 Gamma 3.74 +/- 0.33 10.81 +/- 0.34 5.99 +/- 0.47 0.06 +/- 0.03 19.66 +/- 0.84 215.20 +/- 88.00 0.07 +/- 0.01 1.54 +/- 0.68 0.30 +/- 0.10 5.23 +/- 0.83 3.18 +/- 1.31 273.10 +/- 85.70 175.44 +/- 99.84 3.05 +/- 0.39 0.48 +/- 0.26 4.06 +/- 0.28 0.16 +/- 0.05 0.13 +/- 0.03 14.20 +/- 0.89 0.15 +/- 0.06 0.06 +/- 0.02 214.69 +/- 85.42 159.00 +/- 86.10 156.50 +/- 84.70 1384.60 +/- 111.70 1283.60 +/- 97.45 31.49 +/- 0.70 2.23 +/- 0.86 0.72 +/- 0.12 0.92 +/- 0.52 1304.40 +/- 103.30 11.75 +/- 0.52 2.22 +/- 0.23 0.19 +/- 0.10 7.21 +/- 0.41 2.16 +/- 0.56 25.15 +/- 0.73 26.98 +/- 2.72 3.54 +/- 0.30 10.72 +/- 0.33 5.45 +/- 0.44 0.04 +/- 0.02 20.09 +/- 0.80 292.80 +/- 91.60 0.07 +/- 0.02 1.67 +/- 0.75 0.36 +/- 0.10 6.00 +/- 0.45 2.42 +/- 1.27 219.80 +/- 83.10 180.75 +/- 100.03 3.23 +/- 0.37 0.50 +/- 0.13 3.68 +/- 0.26 0.17 +/- 0.06 0.16 +/- 0.03 12.67 +/- 0.88 0.13 +/- 0.02 0.04 +/- 0.02 314.60 +/- 90.25 159.00 +/- 86.10 170.20 +/- 85.30 1421.60 +/- 107.60 1293.20 +/- 91.37 30.11 +/- 0.80 2.31 +/- 0.92 0.82 +/- 0.14 1.26 +/- 0.53 1496.10 +/- 121.30 10.94 +/- 0.59 1.91 +/- 0.22 0.29 +/- 0.17 7.57 +/- 0.39 1.64 +/- 0.62 25.47 +/- 0.54 28.68 +/- 2.89 3.64 +/- 0.22 10.77 +/- 0.24 5.72 +/- 0.32 0.05 +/- 0.02 19.88 +/- 0.58 254.00 +/- 63.51 0.07 +/- 0.01 1.61 +/- 0.51 0.33 +/- 0.07 5.62 +/- 0.47 2.80 +/- 0.91 246.45 +/- 59.69 178.10 +/- 70.66 3.14 +/- 0.27 0.49 +/- 0.15 3.87 +/- 0.19 0.17 +/- 0.04 0.14 +/- 0.02 13.44 +/- 0.63 0.14 +/- 0.03 0.05 +/- 0.01 264.65 +/- 62.13 159.00 +/- 60.88 163.35 +/- 60.10 1403.10 +/- 77.55 1288.40 +/- 66.79 30.80 +/- 0.53 2.27 +/- 0.63 0.77 +/- 0.09 1.09 +/- 0.37 1400.25 +/- 79.66 11.35 +/- 0.39 2.06 +/- 0.16 0.24 +/- 0.10 7.39 +/- 0.28 1.90 +/- 0.42 25.31 +/- 0.45 27.83 +/- 1.98 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Note: Duplicate analyses are performed on every twentieth sample received in-house. Results are not listed for those analyses with activities that measure below the LLD.

a Results are reported in units of pCi/L, except for air filters (pCi/Filter), food products, vegetation, soil, sediment (pCi/g).

A5-4

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).

Concentration a Known Control Lab Code b Date Analysis Laboratory result Activity Limits C Acceptance STW-1670 02/01/12 1-129 9.31 +/- 0.31 12.29 8.60.- 15.98 STSO-1766 STSO-1766 STSO-1766 STSO-1766 STSO-1 766 STSO-1 766 STSO-1766 STS O-1766 STS O-1766 STSO-1766 STSO-1766 STSO-1766 STSO-1766 STSO-1766 STSO-1766 STAP-1 772 STAP-1 772 STAP-1772 STAP-1 772 STAP-1772 STAP-1772 STAP-1 772 STAP-1772 STAP-1772 STAP-1772e STAP-1 772 STAP-1772 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02101/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 Am-241 Co-57 Co-60 Cs-134 Cs-137 K-40 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Zn-65 Am-241 Co-57 Co-60 Cs-134 Cs-137 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 88.50 1352.10 1.70 842.20 0.40 1729.60 647.60 781.50 142.40 66.10 383.20 289.60 63.20 310.80 766.70

+/- 8.30

+/- 4.00

+/- 0.70

+/- 4.30

+/- 0.90

+/- 22.20

+/- 4.20

+/- 9.70

+/- 9.70

+/- 6.40

+/- 15.30

+/- 10.90

+/- 5.40

+/- 12.10

+/- 6.70 159.00 1179.00 1.56 828.00 0.00 1491.00 558.00 862.00 136.00 65.80 392.00 374.00 68.10 329.00 642.00 111.00 825.00 1.00 580.00 0.00 1044.00 391.00 603.00 97.00 46.10 274.00 262.00 47.70 230.00 449.00

-207.00

-1533.00

-2.00

-1076.00

-1.00

-1938.00

-725.00

-1121.00

-177.00

-85.50

-510.00

-486.00

-88.50

-428.00

-835.00 0.062 +/- 0.02 0.010 +/- 0.01 2.40 +/- 0.08 2.33 +/- 0.13 2.07 +/- 0.10 3.77 +/- 0.14 0.003 +/- 0.004 0.098 +/- 0.017

-0.010 +/- 0.060 0.016 +/- 0.006 0.11 +/- 0.02 3.67 +/- 0.20 0.51 +/- 0.05 2.75 +/- 0.10 14.57 +/- 0.28 6.45 +/- 0.23 8.39 +/- 0.29 0.01 +/- 0.09 0.03 +/- 0.08 10.31 +/- 0.67 1.68 +/- 0.09 6.33 +/- 0.10 0.073 0.00 2.18 2.38 1.79 3.24 0.002 0.097 0.000 0.019 0.12 2.99 1.20 2.40 12.00 6.05 8.43 0.00 0.00 8.90 2.14 6.36 0.051 -0.10 0.000 -1.00 1.53 -2.84 1.67 -3.09 1.25 - 2.33 2.27 - 4.21 0.000 -0.10 0.07 -0.13

-0.10 -0.13 0.013 - 0.024 0.09 -0.16 2.09 - 3.89 0.40 - 2.00 1.20 - 3.60 8.40 - 15.60 4.24 - 7.87 5.90 - 10.96 0.00 -0.10 0.00 -0.10 6.23 -11.57 0.64 - 3.64 3.18 -9.54 Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STAP-1773 02/01/12 Gr. Alpha STAP-1773 02/01/12 Gr. Beta STVE-1776 STVE-1776 STVE-1776 STVE-1776 STVE-1776 STVE-1776 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 Co-57 Co-60 Cs-134 Cs-137 Mn-54 Zn-65 STW-1960 02/01/12 Gr. Alpha STW-1960 02/01/12 Gr. Beta A6-1

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).

Concentration a Known Control Lab Code b Date Analysis Laboratory result Activity Limits C Acceptance STW-1964 STW-1964 STW-1 964 STW-1 964 STW-1964 STW-1964 STW-1964 STW-1964 STW-1964 STW-1964 STW-1964 STW-1964 STW-1964 STW-1964 STW-1964 STW-1 964 STW-1964 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 02/01/12 Am-241 Co-57 Co-60 Cs-134 Cs-137 Fe-55 H-3 K-40 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Zn-65 1.28 +/- 0.12 33.30 +/- 0.40 23.20 +/- 0.40 0.30 +/- 3.00 40.10 +/- 0.60 65.10 +/- 9.50 460.00 +/- 12.10 153.00 +/- 4.20 32.70 +/- 0.60 49.80 +/- 2.90 0.58 +/- 0.06 1.30 +/- 0.15 0.10 +/- 0.20 23.70 +/- 0.80 0.40 +/- 0.05 2.67 +/- 0.13 0.01 +/- 0.20 5.73 +/- 0.28 129.30 +/- 12.70 376.20 +/- 20.60 118.70 +/- 9.30 140.70 +/- 9.90 483.52 +/- 16.47 432.50 +/- 23.10 1528.00 +/- 4.10 592.00 +/- 3.20 933.60 +/- 5.82 1319.80 +/- 5.50 737.30 +/- 17.70 1083.20 +/- 5.20 55.80 +/- 4.20 231.20 +/- 8.60 696.10 + 7.00 1.63 32.90 23.72 0.00 39.90 81.90 437.00 142.00 31.80 60.00 0.63 1.34 0.00 27.90 0.39 2.76 0.00 6.82 111.00 406.00 105.80 134.00 508.00 469.00 1316.00 531.00 939.00 1150.00 632.00 920.00 60.30 263.00 606.00 1.14 -2.12 23.00 - 42.80 16.60 -30.84 0.00 -1.00 27.90 - 51.90 57.30 - 106.50 306.00 - 568.00 99.00 - 185.00 22.30 - 41.30 42.00 - 78.00 0.44 - 0.82 0.94-1.74 0.00 - 1.00 19.50 - 36.30 0.27 - 0.51 1.93 -3.59 0.00 - 1.00 4.77 - 8.87 78.00 - 144.00 284.00 - 528.00 74.10 - 137.50 94.00 - 174.00 356.00 - 660.00 328.00 - 610.00 921.00 - 1711.00 372.00 - 690.00 657.00 - 1221.00 805.00 - 1495.00 442.00 - 822.00 644.00 - 1196.00 42.20 - 78.40 184.00 - 342.00 424.00 - 788.00 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STW-5391 08/01/12 1-129 STSO-5392 STSO-5392 STSO-5392 STSO-5392 STSO-5392 STSO-5392 STSO-5394 STSO-5394 STSO-5394 STSO-5394 STSO-5394 STSO-5394 STSO-5394 STSO-5394 STSO-5394 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 08/01/12 Am-241 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 Co-57 Co-60 Cs-134 Cs-137 K-40 Mn-54 U-233/4 U-238 Zn-65 A6-2

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).

Concentration a Known Control Lab Code b Date Analysis Laboratory result Activity Limits c Acceptance STVE-5395 1 08/01/12 Co-57 7.44 +/- 0.17 5.66 3.96 - 7.36 Fail STVE-5395 08/01/12 Co-60 5.90 +/- 0.15 5.12 3.58 - 6.66 Pass STVE-5395 08/01/12 Cs-134 7.40 +/- 0.31 6.51 4.56 -8.46 Pass STVE-5395 08/01/12 Cs-137 5.45 +/- 0.18 4.38 3.07 -5.69 Pass STVE-5395 08/01/12 Mn-54 4.06 +/- 0.21 3.27 2.29 -4.25 Pass STAP-5398 08/01/12 Gr. Alpha 0.41 +/- 0.05 0.97 0.29 - 1.65 Pass STAP-5398 08/01/12 Gr. Beta 2.11 +/- 0.09 1.92 0.96 - 2.88 Pass STAP-5401 08/01/12 Am-241 0.12 +/- 0.02 0.08 0.05 - 0.10 Fail STAP-5403 08/01/12 Co-57 1.96 +/- 0.05 1.91 1.34 -2.48 Pass STAP-5403 08/01/12 Co-60 1.76 +/- 0.07 1.73 1.21 -2.25 Pass STAP-5403 08/01/12 Cs-134 2.74 +/- 0.18 2.74 1.92 -3.56 Pass STAP-5403 08/01/12 Cs-137 0.00 +/- 0.03 0.00

-0.01 - 0.01 Pass STAP-5403 08/01/12 Mn-54 2.52 +/- 0.10 2.36 1.65 - 3.07 Pass STAP-5403 08/01/12 Pu-238 0,050 +/- 0.015 0.063 0.044 - 0.081 Pass STAP-5403 08/01/12 Pu-239/40 0.001 +/- 0.004 0.00081 0.000 - 0.010 Pass STAP-5403' 08/01/12 U-233/4 0.009 +/- 0.011 0.014 0.010 - 0.018 Fail STAP-5403 08/01/12 U-238 0.08 +/- 0.02 0.10 0.070 - 0.130 Pass STAP-5403 08/01/12 Zn-65 0.01 +/- 0.06 0.00

-0.010 - 0.010 Pass STW-5445 08/01/12 Fe-55 79.80 +/- 4.10 89.30 62.50 -116.10 Pass STW-5445 08/01/12 Ni-63 74.30 +/- 3.40 66.30 46.40 - 86.20 Pass STW-5445 08/01/12 U-233/4 0.46 +/- 0.05 0.45 0.32 - 0.59 Pass STW-5445 08/01/12 U-238 3.14 +/- 0.14 3.33 2.33 -4.33 Pass STW-54451 08/01/12 Am-241 0.64 +/- 0.04 1.06 0.74 -1.38 Fail a Results are reported in units of Bq/kg (soil), Bq/L (water) or Bq/total sample (filters, vegetation).

Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation).

c MAPEP results are presented as the known values and expected laboratory precision (1 sigma, 1 determination) and control limits as defined by the MAPEP. A known value of "zero" indicates an analysis was included in the testing series as a "false positive". MAPEP does not provide control limits.

Investigation was inconclusive, there was not enough sample for reanalysis. ERA results (A-7) for the same matrix were acceptable.

e No errors found in calculation or procedure, original analysis result; 0.010 +/- 0.010 Bq/filter.

f Reanalysis results were within limits, but low. ERA results (A-7) for the same matrix were acceptable.

The efficiency factor was recalculated for the second round of MAPEP testing. Original analysis results 55.8 +/- 12.6 Bq/L.

g Result of reanalysis; 6.74 +/- 0.15 Bq/sample. Gamma emitters for the vegetation matrix exhibited a high bias, only Co-57 exceeded acceptance limits. Recounted using a geometry more closely matched to the MAPEP sample size.

Result of reanalysis; 0.070 +/- 0.013 Bq/filter.

Result of reanalysis; 0.013 + 0.005 pCi/filter. A larger sample size was used to reduce the counting error.

Result of reanalysis 1.07 t 0.06 pCi/L. The analyses of the MAPEP sample matrix resulted in recovery factors greater than 100%.

A correction was made using recovery based on analysis of blank samples. A new tracer solution is on order, future samples for MAPEP testing will include batch spike and blank samples.

A6-3

TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)'.

Concentration (pCi/L) b Lab Code b Date Analysis Laboratory ERA Control Result c Result d Limits Acceptance ERAP-1393 ERAP-1393 ERAP-1393 ERAP-1393 ERAP-1393 ERAP-1394 ERAP-1394 ERAP-1394 ERAP-1394 ERAP-1394 ERAP-1394 ERAP-1394 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 Co-60 Cs-134 Cs-137 Mn-54 Zn-65 Am-241 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Uranium ERAP-1396 03/19/12 Gr. Alpha ERAP-1396 03/19/12 Gr. Beta ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 ERSO-1397 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 Ac-228 Am-241 Bi-212 Bi-214 Co-60 Cs-134 Cs-137 K-40 Mn-54 Pb-212 Pb-214 Pu-238 Pu-239/40 Sr-90 Th-234 U-233/4 U-238 Uranium Zn-65 917.5 +/- 7.0 586.6 +/- 7.4 1255.9 +/- 9.4

< 3.4 1085.2 +/- 18.0 86.9 +/- 2.9 70.2 +/- 3.6 66.0 +/- 1.0 112.5 +/- 15.4 43.4 +/- 0.8 44.0 +/- 1.2 89.1 +/- 2.2 81.1 +/- 1.5 68.4 +/- 0.7 1303.4 +/- 89.3 856.0 +/- 123.7 1379.2 +/- 247.2 965.2 +/- 38.4 3693.6 +/- 32.1 2257.3 +/- 45.4 9444.5 +/- 58.4 11277.0 +/- 275.1

< 21.0 1208.4 +/- 26.3 1041.6 +/- 46.9 921.0 +/- 112.6 1028.0 +/- 112.6 8128.0 +/- 329.0 2711.3 +/- 253.6 1859.3 +/- 126.6 2003.3 +/- 130.3 3939.5 +/- 283.8 4200.4 +/- 65.9 880.0 656.0 1130.0 0.0 897.0 68.8 63.2 63.0 89.6 47.5 47.1 96.7 77.8 52.5 1570.0 938.0 1550.0 1100.0 3500.0 2180.0 8770.0 11600.0 0.0 1510.0 1110.0 984.0 879.0 8800.0 2000.0 1960.0 2000.0 4030.0 3650.0 681.0 -1100.0 417.0 -814.0 849.0 - 1480.0 642.0 - 1240.0 42.4 -93.1 43.3 - 83.1 45.6 - 82.4 43.8-134.0 29.4 -71.6 30.4 -65.1 53.5-147.0 26.1 -121.0 33.2 -76.5 1010.0 -2180.0 549.0 -1220.0 413.0 - 2280.0 665.0 -1590.0 2370.0 -4820.0 1420.0 - 2620.0 6720.0 -11300.0 8470.0 - 15600.0 992.0 -2110.0 647.0 - 1650.0 592.0 -1360.0 575.0 - 1210.0 3360.0 -13900.0 632.0 - 3760.0 1200.0 - 2510.0 1240.0 - 2540.0 2190.0 -5320.0 2910.0 -4850.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A7-1

TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)'.

Concentration (pCi/L) b Lab Code b Date Analysis Laboratory ERA Control Result c Result o Limits Acceptance ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERVE-1400 ERW-1403 ERW-1403 ERW-1403 ERW-1403 ERW-1403 ERW-1403 ERW-1403 ERW-1405 ERW-1405 ERW-1405 ERW-1405 ERW-1405 ERW-1405 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03119/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 03/19/12 Am-241 Cm-244 Co-60 Cs-134 Cs-137 K-40 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Uranium Zn-65 Am-241 Fe-55 Pu-238 Pu-239/40 U-233/4 U-238 Uranium Co-60 Cs-134 Cs-137 Mn-54 Sr-90 Zn-65 4194.8 +/- 199.5 1471.2 +/- 113.1 2347.8 +/- 47.9 2847.5 +/- 64.0 1503.5 +/- 52.5 34105.7 +/- 745.3

< 26.8 2509.0 +/- 213.6 2690.4 +/- 208.9 7881.5 +/- 470.8 3149.6 +/- 165.2 3203.6 +/- 166.5 6463.7 +/- 363.2 2701.9 +/- 105.5 119.9 +/-3.2 713.7 +/- 127.4 131.9 +/- 6.4 108.9 +/- 10.2 93.1 +/- 7.9 96.9 +/- 5.5 190.0 +/- 13.8 858.7 +/- 5.6 560.4 +/- 4.4 1239.9 +/- 7.4

< 7.4 944.3 +/- 26.2 786.9 +/- 20.6 85.9 +/- 3.0 45.7 +/- 1.6 9045.0 +/- 284.0 4540.0 1590.0 2210.0 2920.0 1340.0 28600.0 0.0 2350.0 2570.0 8520.0 3610.0.

3580.0 7350.0 2310.0 135.0 863.0 135.0 112.0 105.0 104.0 214.0 875.0 609.0 1250.0 0.0 989.0 749.0 103.0 43.7 2780.0 - 6040.0 779.0 - 2480.0 1520.0 - 3090.0 1880.0 - 3790.0 972.0 - 1860.0 20700.0 - 40100.0 1400.0 - 3220.0 1580.0 - 3540.0 4860.0 - 11300.0 2370.0 - 4640.0 2390.0 - 4550.0 4980.0 - 9150.0 1670.0 - 3240.0 91.0-181.0 514.0 - 1170.0 99.9 - 168.0 86.9-141.0 78.9 - 135.0 79.3 - 128.0 157.0 -277.0 760.0 - 1020.0 447.0 - 700.0 1060.0 - 1500.0 644.0 - 1310.0 624.0 - 945.0 36.6 - 160.0 25.0 - 64.7 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass ERW-1406 03/19/12 Gr. Alpha ERW-1406 03/19/12 Gr. Beta ERW-1409 03/19/12 H-3 9150.0 6130.0 - 13000.0 Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurements Laboratory Quality Assessment Program (EML).

b Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation). Results are reported in units of pCi/L, except for air filters (pCi/Filter), vegetation and soil (pCi/kg).

c Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.

d Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA. A known value of "zero" indicates an analysis was included in the testing series as a "false positive". Control limits are not provided.

A7-2

Appendix B Summary Tables in the format of NRC Radiological Assessment Branch Technical Position Revision 1, November 1979 Page B-1

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

Name of Facility: Wolf Creek Generating Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2012 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection

    • Mean (f)

Distance and

    • Mean (f)
    • Mean (f)

Reported Measurement)

(LLD)

    • Range Direction
    • Range
    • Range Measurements **

Air Particulate (pCi/m 3)

Gross Beta (324) 0.01 0.029 (270/270)

(0.009 - 0.064) 49 0.8 miles NNE 37 2.0 miles NNW 0.031 (54/54)

(0.012 - 0.064) 0.085 (4/4)

(0.052 - 0.103)

Station 53 0.029 (54/54)

(0.011 - 0.064) 0.090 (4/4)

(0.065 - 0.113) 0 Gamma (24)

Be-7 0.082 (20/20)

(0.052 - 0.105) 0 Air Radioiodine (pCi/m 3)

Direct Radiation Dosimeters (mR per std.

90-day Qtr.)

Surface Water (pCi/I)

Station 53

- (0/54) 1-131 (324) 0.07

-(0/270)

N/A N/A 0

Stations 39 & 53 Gamma Dose (172)

Gamma (24)

Tritium (24)

Fe-55 (8) 1-131 (32)

Gamma (32)

Tritium (32) 19.5 (164/164)

(10.0- 27.9) 47 0.16 miles S 24.8 (4/4)

(19.9 - 27.9) 18.6 (8/8)

(14.7 - 22.2) 0

- (0/12)

N/A N/A 3,000 11,435 (12/12)

(10,037-12,545)

- (0/4)

SP 3.2 miles SSE 11,435 (12/12)

(10,037-12,545)

Ground Water (pCi/I) 1

- (0/28)

N/A N/A N/A N/A N/A N/A N/A N/A JRR

- (0/12)

- (0/12)

- (0/4)

B-12

- (0/4)

- (0/4)

- (0/4) 0 0

0 0

0 0

- (0/28) 2,000

-(0/28)

Page B-2

    • Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

Name of Facility: Wolf Creek Generating Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2012 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection

    • Mean (f)

Distance and

    • Mean (f)
    • Mean (f)

Reported Measurement)

(LLD)

    • Range Direction
    • Range
    • Range Measurements **

Drinking Water (pCi/I) 1-131 (25)

Gross Beta (25)

Gamma (25) 1

-(0/12) 4 3.0 (12/12)

(2.1 -3.7)

N/A 1O-DW 26.1 miles SSE N/A BW-1 5

- (0/13) 2.8 (13/13)

(1.2 -4.0) 3.0 (12/12)

(2.1 -3.7) 0 0

0 0

- (0/12)

N/A N/A

- (0/13)

- (0/4)

Tritium (8)

Gamma (6) 2,000 222 (1/4) 1O-DW 26.1 miles SSE 222 (1/4)

Shoreline Sediment (pCi/kg dry)

JRR 8,298 (2/2)

(6,356 - 10,239)

K-40 8,827 (4/4)

(6,074 - 12,147)

SC 0.8 miles NNW EEA 3.0 miles NNW 12,147 (1/1) 234.3 (1/1) 0 0

Cs-1 37 180 155.1 (2/4)

(75.8 - 234.3)

- (0/2)

Fish (pCi/kg wet)

Gamma (17)

JRR K-40 3,149 (9/9)

(2,837 - 3,547) 7,728 (9/9)

(6,808 - 8,948)

CCL 0.6 miles E to NNW CCL 0.6 miles E to NNW 3,149 (9/9)

(2,837 - 3,547) 7,728 (9/9)

(6,808 - 8,948) 3,165 (8/8)

(2,944 - 3,497) 0 0

Tritium (17)

-(0/8)

Page B-3

    • Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

Name of Facility: Wolf Creek Generating Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2012 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection

    • Mean (f)

Distance and

    • Mean (f)
    • Mean (f)

Reported Measurement)

(LLD)

    • Range Direction
    • Range
    • Range Measurements **

Food and Garden (pCi/kg wet)

Gamma (30)

D-2 Be-7 K-40 820 (20/21)

(212 - 3,348) 5,935 (21/21)

(3,868 - 9,300)

Q-6 2.4 miles NW B-1 0.8 miles NNE 1,273 (6/6)

(212 - 3,348) 6,567 (7/7)

(4,921 - 9,300) 524 (6/9)

(262 - 764) 0 0

4,990 (9/9)

(3,033 - 5,892)

NR-U1 Crops (pCi/kg wet)

Bottom Sediment (pCi/kg dry)

Gamma (3)

K-40 8,671 (2/2)

(3,033 - 14,309)

NR-D1 8.9 miles S 14,309 (1/1) 2,994 (1/1) 0 Gamma (19)

JRR 10,677 (2/2)

(9,398 - 11,955)

K-40 9,766 (17/17)

(7,502 - 11,301)

EEA 3.0 miles NNW 11,179 (1/1) 96 (4/10)

(68-126)

Cs-1 37 Fe-55 (14) 76 (9/17)

(26-126)

-(0/14)

UHS 0.6 miles E 84 (2/2)

(45-122) 0 0

0 N/A N/A Page B-4

    • Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

Name of Facility: Wolf Creek Generatinq Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2012 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection

    • Mean (f)

Distance and

    • Mean (f)
    • Mean (f)

Reported Measurement)

(LLD)

    • Range Direction
    • Range
    • Range Measurements **

Aquatic Vegetation (pCi/kg wet)

Gamma (4)

No Control Be-7 K-40 655 (3/4)

(314-1,196) 2,827 (4/4)

(1,925 - 4,601)

DC-ALT 1.5 miles NW EEA 3.0 miles NNW 1,196(1/1) 4,601 (1/1) 0 0

Terrestrial Vegetation (pCi/kg wet)

Gamma (1)

No Control Be-7 K-40 1,084 (1/1) 13,379 (1/1)

EEA 3.0 miles NNW EEA 3.0 miles NNW 1,084(1/1) 13,379 (1/1) 0 0

Soil (pCi/kg dry)

Gamma (1)

No Control K-40 8,520 (1/1) 155(1/1)

EEA 3.0 miles NNW EEA 3.0 miles NNW 8,520 (1/1) 155(1/1) 0 0

Cs-137 Deer (pCi/kg wet)

Gamma (1)

No Control K-40 2,640 (1/1) 916(1/1)

A1.5 1.5 miles N A1.5 1.5 miles N 2,640 (1/1) 916(1/1) 0 0

Tritium (1)

Page B-5

    • Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)

Air Particulate and Charcoal Filters Location: 002 Collection Start Date 27-DEC-i 1 03-JAN-1 2 09-JAN-1 2 16-JAN-12 23-JAN-1 2 30-JAN-12 06-FEB-1 2 15-FEB-1 2 21-FEB-1 2 27-FEB-1 2 27-FEB-12 05-MAR-12 12-MAR-12 19-MAR-12 19-MAR-12 26-MAR-12 02-APR-12 09-APR-1 2 16-APR-12 24-APR-12 30-APR-12 08-MAY-12 08-MAY-12 14-MAY-12 21-MAY-12 29-MAY-1 2 04-JUN-12 11-JUN-12 11-JUN-12 18-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 06-AUG-1 2 13-AUG-12 20-AUG-12 Collection End Date 03-JAN-12 09-JAN-12 16-JAN-12 23-JAN-12 30-JAN-12 06-FEB-12 15-FEB-12 21-FEB-1 2 27-FEB-1 2 05-MAR-1 2 05-MAR-1 2 12-MAR-1 2 19-MAR-12 26-MAR-12 26-MAR-12 02-APR-1 2 09-APR-1 2 16-APR-12 24-APR-12 30-APR-12 08-MAY-1 2 14-MAY-1 2 14-MAY-1 2 21 -MAY-1 2 29-MAY-1 2 04-JUN-12 11-JUN-12 18-JUN-12 18-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 23-JUL-12 30-JUL-12 06-AUG-12 13-AUG-12 20-AUG-12 27-AUG-1 2 Volume Gross Beta m 3 Concentration (pCilm3 )

1-131 Concentration (pCi/m 3)

Duplicate Analysis 305 255 298 314 304 302 388 260 266 291 291 298 290 302 302 299 301 308 347 252 336 255 255 309 338 237 282 291 291 278 303 298 296 299 299 296 294 296 302 298 0.020 0.020 0.020 0.040 0.015 0.019 0.027 0.028 0.013 0.018 0.024 0.019 0.017 0.014 0.012 0.028 0.022 0.022 0.019 0.027 0.019 0.022 0.023 0.027 0.022 0.020 0.021 0.020 0.018 0.017 0.040 0.023 0.034 0.027 0.028 0.026 0.035 0.026 0.024 0.032

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.004 0.004 0.003 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.005 0.004 0.005 0.005 0.004 0.003 0.005 0.005 0.004 0.004 0.004 0.005 0.004 0.005 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.010 0.012 0.009 0.011 0.018 0.013 0.013 0.016 0.010 0.011 0.017 0.014 0.010 0.012 0.013 0.020 0.016 0.013 0.019 0.011 0.008 0.008 0.011 0.007 0.011 0.013 0.008 0.012 0.018 0.008 0.013 0.011 0.011 0.011 0.014 Duplicate Duplicate Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-1

Air Particulate and Charcoal Filters Location: 002 Collection Start Date 27-AUG-12 04-SEP-1 2 04-SEP-12 10-SEP-12 10-SEP-12 17-SEP-12 24-SEP-1 2 01-OCT-12 08-OCT-1 2 15-OCT-12 22-OCT-1 2 29-OCT-12 05-NOV-12 05-NOV-12 12-NOV-12 19-NOV-12 26-NOV-12 03-DEC-1 2 10-DEC-1 2 17-DEC-12 26-DEC-1 2 31-DEC-1 2 Collection End Date 04-SEP-12 10-SEP-12 10-SEP-12 17-SEP-12 17-SEP-12 24-SEP-12 01-OCT-12 08-OCT-12 15-OCT-12 22-OCT-12 29-OCT-12 05-NOV-12 12-NOV-12 12-NOV-12 19-NOV-12 26-NOV-1 2 03-DEC-12 10-DEC-12 17-DEC-12 26-DEC-12 31-DEC-12 07-JAN-13 Volume Gross Beta m 3 Concentration (pCi/m 3 )

1-131 Concentration (pCi/m 3)

Duplicate Analysis 334 258 258 303 303 307 293 310 310 302 307 309 303 303 300 307 330 319 300 387 210 313 0.031 0.027 0.029 0.025 0.028 0.020 0.040 0.033 0.035 0.029 0.028 0.054 0.020 0.026 0.063 0.055 0.051 0.032 0.054 0.051 0.042 0.037

+1-

+1-

+1-

+1-

+1-

+1-

.1-I-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.004 0.005 0.005 0.004 0.004 0.004 0.005 0.005 0.004 0.004 0.004 0.005 0.004 0.004 0.005 0.005 0.005 0.004 0.005 0.004 0.006 0.004

< 0.020

< 0.006

< 0.016

< 0.006

< 0.013

< 0.018

< 0.014

< 0.010

< 0.012

< 0.011

< 0.011

< 0.011

< 0.015

< 0.008

< 0.007

< 0.018

< 0.009

< 0.019

< 0.013 Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 2

Air Particulate and Charcoal Filters Location: 018 Collection Start Date 27-DEC-i 1 03-JAN-12 09-JAN-1 2 16-JAN-12 23-JAN-1 2 30-JAN-12 06-FEB-12 15-FEB-12 21-FEB-12 27-FEB-1 2 05-MAR-12 12-MAR-12 19-MAR-12 26-MAR-12 02-APR-12 09-APR-12 16-APR-1 2 24-APR-1 2 30-APR-12 08-MAY-12 14-MAY-12 21-MAY-12 29-MAY-12 04-JUN-12 11-JUN-12 18-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 06-AUG-12 13-AUG-12 20-AUG-12 27-AUG-12 04-SEP-12 10-SEP-12 17-SEP-12 24-SEP-12 Collection End Date 03-JAN-1 2 09-JAN-1 2 16-JAN-12 23-JAN-12 30-JAN-12 06-FEB-12 15-FEB-12 21-FEB-12 27-FEB-12 05-MAR-12 12-MAR-1 2 19-MAR-1 2 26-MAR-1 2 02-APR-12 09-APR-12 16-APR-12 24-APR-1 2 30-APR-1 2 08-MAY-12 14-MAY-12 21-MAY-12 29-MAY-12 04-JUN-12 11-JUN-12 18-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 06-AUG-12 13-AUG-12 20-AUG-12 27-AUG-1 2 04-SEP-12 10-SEP-12 17-SEP-12 24-SEP-12 01-OCT-12 Volume Gross Beta m3 Concentration (pCi/m3 )

1-131 Concentration (pCilm 3)

Duplicate Analysis 305 262 304 315 299 305 392 261 259 285 305 292 297 306 306 308 339 255 337 258 305 339 251 302 305 302 298 298 303 295 298 295 297 298 299 331 256 302 308 296 0.017 0.022 0.025 0.039 0.017 0.018 0.027 0.030 0.009 0.021 0.018 0.017 0.016 0.026 0.023 0.019 0.018 0.026 0.024 0.025 0.024 0.023 0.017 0.020 0.018 0.020 0.045 0.021 0.033 0.029 0.024 0.033 0.025 0.027 0.035 0.034 0.032 0.023 0.020 0.043

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-4I-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.005 0.004 0.004 0.005 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.005 0.010 0.012 0.009 0.011 0.019 0.013 0.013 0.016 0.010 0.011 0.017 0.014 0.011 0.012 0.012 0.020 0.016 0.013 0.019 0.011 0.008 0.009 0.010 0.006 0.011 0.012 0.008 0.012 0.017 0.009 0.013 0.011 0.011 0.011 0.014 0.020 0.006 0.016 0.006 0.013 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 3

Air Particulate and Charcoal Filters Location: 018 Collection Start Date 24-SEP-12 01-OCT-12 08-OCT-12 15-OCT-12 22-OCT-1 2 29-OCT-1 2 05-NOV-12 12-NOV-12 19-NOV-12 26-NOV-1 2 03-DEC-12 10-DEC-12 17-DEC-12 26-DEC-12 31-DEC-12 Collection End Date 01-OCT-12 08-OCT-12 15-OCT-1 2 22-OCT-1 2 29-OCT-1 2 05-NOV-12 12-NOV-12 19-NOV-12 26-NOV-12 03-DEC-12 10-DEC-1 2 17-DEC-1 2 26-DEC-1 2 31-DEC-1 2 07-JAN-13 Volume Gross Beta m3 Concentration (pCi/r 3 )

1-131 Concentration (pCi/m 3)

Duplicate Analysis Duplicate 296 309 294 307 306 299 305 290 304 295 311 302 384 212 315 0.037 0.027 0.034 0.028 0.028 0.054 0.022 0.063 0.056 0.050 0.029 0.056 0.053 0.044 0.046

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.005 0.004 0.005 0.004 0.004 0.005 0.004 0.005 0.005 0.005 0.004 0.005 0.004 0.006 0.005 0.018 0.015 0.010 0.012 0.011 0.011 0.011 0.015 0.009 0.008 0.018 0.009 0.019 0.013 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 4

Air Particulate and Charcoal Filters Location: 032 Collection Start Date 27-DEC-i 1 03-JAN-12 09-JAN-12 09-JAN-12 16-JAN-12 23-JAN-12 30-JAN-1 2 06-FEB-12 15-FEB-12 21-FEB-12 27-FEB-12 05-MAR-1 2 12-MAR-1 2 19-MAR-1 2 26-MAR-12 02-APR-12 02-APR-12 09-APR-12 16-APR-12 24-APR-12 30-APR-1 2 08-MAY-1 2 14-MAY-1 2 21-MAY-1 2 29-MAY-12 04-JUN-12 11-JUN-12 18-JUN-12 25-JUN-1 2 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 06-AUG-12 13-AUG-12 20-AUG-12 27-AUG-12 04-SEP-12 10-SEP-12 Collection End Date 03-JAN-1 2 09-JAN-1 2 16-JAN-12 16-JAN-12 23-JAN-12 30-JAN-12 06-FEB-12 15-FEB-12 21-FEB-12 27-FEB-1 2 05-MAR-1 2 12-MAR-12 19-MAR-1 2 26-MAR-12 02-APR-12 09-APR-1 2 09-APR-12 16-APR-12 24-APR-1 2 30-APR-12 08-MAY-12 14-MAY-12 21-MAY-12 29-MAY-1 2 04-JUN-12 11-JUN-12 18-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 06-AUG-12 13-AUG-12 20-AUG-1 2 27-AUG-1 2 04-SEP-12 10-SEP-12 17-SEP-12 Volume Gross Beta m 3 Concentration (pCirm 3 )

1-1.31 Concentration (pCi/m 3)

Duplicate Analysis 307 255 299 299 315 301 303 391 259 267 294 300 292

'302 297 306 306 310 360 254 340 260 309 334 254 304 300 300 302 300 299 297 297 296 296 295 298 334 257 301 0.015 0.018 0.021 0.021 0.042 0.018 0.016 0.024 0.031 0.015 0.022 0.022 0.017 0.014 0.029 0.021 0.020 0.014 0.022 0.029 0.019 0.025 0.021 0.024 0.016 0.023 0.021 0.021 0.041 0.025 0.031 0.027 0.028 0.029 0.025 0.026 0.030 0.032 0.026 0.025

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.004 0.004 0.003 0.003 0.004 0.004 0.003 0.003 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.003 0.005 0.004 0.004 0.005 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.010 0.012 0.009 0.011 0.019 0.013 0.013 0.016 0.010 0.011 0.017 0.014 0.010 0.012 0.012 0.020 0.015 0.013 0.019 0.011 0.008 0.010 0.010 0.006 0.011 0.012 0.008 0.012 0.018 0.008 0.013 0.011 0.011 0.011 0.014 0.020 0.006 0.016 Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 5

Air Particulate and Charcoal Filters Location: 032 Collection Start Date 17-SEP-12 24-SEP-12 01-OCT-12 08-OCT-12 15-OCT-1 2 22-OCT-12 29-OCT-1 2 05-NOV-12 12-NOV-12 12-NOV-12 19-NOV-12 26-NOV-12 26-NOV-12 03-DEC-12 10-DEC-12 17-DEC-12 26-DEC-12 31-DEC-12 Collection End Date 24-SEP-12 01-OCT-12 08-OCT-12 15-OCT-12 22-OCT-12 29-OCT-12 05-NOV-12 12-NOV-12 19-NOV-12 19-NOV-12 26-NOV-1 2 03-DEC-12 03-DEC-12 10-DEC-12 17-DEC-1 2 26-DEC-12 31-DEC-1 2 07-JAN-1 3 Volume m 3 Gross Beta Concentration (pCi/m 3 )

1-131 Concentration (pCilm 3)

Duplicate Analysis 310 295 310 302 298 306 302 305 297 297 305 296 296 319 299 385 212 318 0.022 0.036 0.032 0.033 0.029 0.024 0.054 0.024 0.060 0.064 0.050 0.056 0.050 0.029 0.056 0.052 0.043 0.046

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.004 0.005 0.005 0.004 0.005 0.004 0.005 0.004 0.005 0.005 0.005 0.005 0.005 0.004 0.005 0.004 0.006 0.005 0.006 0.013 0.018 0.015 0.011 0.012 0.011 0.011 0.011

< 0.015

< 0.009 Duplicate Duplicate 0.007 0.018 0.009 0.019 0.013 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 6

Air Particulate and Charcoal Filters Location: 037 Collection Start Date 27-DEC-i 1 27-DEC-1i1 03-JAN-1 2 09-JAN-1 2 16-JAN-12 23-JAN-12 23-JAN-12 30-JAN-12 30-JAN-12 06-FEB-12 15-FEB-12 15-FEB-12 21-FEB-1 2 27-FEB-12 05-MAR-12 12-MAR-12 19-MAR-1 2 26-MAR-12 02-APR-1 2 09-APR-12 16-APR-12 24-APR-12 24-APR-12 30-APR-12 08-MAY-1 2 14-MAY-1 2 21 -MAY-1 2 29-MAY-1 2 04-JUN-12 04-JUN-12 11-JUN-12 18-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 06-AUG-12 13-AUG-12 Collection End Date 03-JAN-12 03-JAN-12 09-JAN-12 16-JAN-1 2 23-JAN-1 2 30-JAN-1 2 30-JAN-12 06-FEB-12 06-FEB-12 15-FEB-12 21-FEB-12 21-FEB-12 27-FEB-12 05-MAR-12 12-MAR-12 19-MAR-12 26-MAR-1 2 02-APR-12 09-APR-12 16-APR-12 24-APR-12 30-APR-12 30-APR-1 2 08-MAY-12 14-MAY-12 21-MAY-12 29-MAY-12 04-JUN-12 11-JUN-12 11-JUN-12 18-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 06-AUG-12 13-AUG-12 20-AUG-12 Volume Gross Beta m3 Concentration (pCi/m 3 )

1-131 Concentration (pCi/m 3)

Duplicate Analysis 306 306 255 302 316 303 303 307 307 389 260 260 268 295 299 292 304 299 303 308 343 255 255 345 255 309 331 259 307 307 303 300 297 301 298 298 296 297 299 299 0.017 0.015 0.020 0.022 0.042 0.016 0.016 0.022 0.018 0.024 0.030 0.028 0.014 0.020 0.022 0.019 0.015 0.028 0.020 0.018 0.023 0.027 0.028 0.016 0.026 0.024 0.023 0.019 0.025 0.025 0.014 0.022 0.041 0.026 0.031 0.030 0.024 0.028 0.027 0.022

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.004 0.003 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.005 0.003 0.005 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004

< 0.010

< 0.012

< 0.009

< 0.011

< 0.018

< 0.013

< 0.013

< 0.016

< 0.010

< 0.010

< 0.017

< 0.014

< 0.010

< 0.012

< 0.012

< 0.020

< 0.016

< 0.013 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 0.019 0.011 0.008 0.010 0.010 0.006 0.011 0.012 0.008 0.012 0.018 0.008 0.013 0.011 0.011 0.011 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 7

Air Particulate and Charcoal Filters Location: 037 Collection Start Date 20-AUG-12 27-AUG-12 04-SEP-12 10-SEP-12 17-SEP-12 24-SEP-1 2 01-OCT-12 08-OCT-12 15-OCT-12 22-OCT-12 29-OCT-12 29-OCT-1 2 05-NOV-12 12-NOV-12 19-NOV-12 26-NOV-12 03-DEC-12 10-DEC-12 17-DEC-12 26-DEC-12 31-DEC-12 Collection End Date 27-AUG-12 04-SEP-12 10-SEP-12 17-SEP-12 24-SEP-12 01-OCT-12 08-OCT-12 15-OCT-12 22-OCT-12 29-OCT-12 05-NOV-1 2 05-NOV-1 2 12-NOV-12 19-NOV-12 26-NOV-12 03-DEC-1 2 10-DEC-12 17-DEC-12 26-DEC-12 31-DEC-12 07-JAN-13 Volume m

3 Gross Beta Concentration (pCi/mr3 )

1-131 Concentration (pCi/m 3)

Duplicate Analysis 300 338 260 299 309 298 311 308 308 317 303 303 303 300 312 291 316 299 389 212 321 0.033 0.031 0.031 0.026 0.022 0.038 0.024 0.034 0.031 0.026 0.052 0.060 0.024 0.060 0.053 0.047 0.029 0.053 0.054 0.048 0.045

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-4-I-

+1-

+1-

+1-

+1-0.004 0.004 0.005 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.005 0.004 0.005 0.005 0.005 0.004 0.005 0.004 0.006 0.005 0.014 0.020 0.006 0.016 0.006 0.013 0.018 0.014 0.010 0.011 0.011 0.011 0.011 0.015 0.009 0.007 0.018 0.009 0.019 0.013 Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 8

Air Particulate and Charcoal. Filters Location: 049 Collection Start Date 27-DEC-i 1 03-JAN-1 2 09-JAN-12 16-JAN-12 23-JAN-12 30-JAN-1 2 06-FEB-12 15-FEB-12 21-FEB-12 27-FEB-12 05-MAR-1 2 12-MAR-12 19-MAR-12 26-MAR-12 02-APR-1 2 09-APR-12 16-APR-12 16-APR-12 24-APR-1 2 30-APR-1 2 08-MAY-1 2 14-MAY-12 21-MAY-12 29-MAY-12 04-JUN-12 11-JUN-12 18-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 30-JUL-12 06-AUG-12 13-AUG-12 20-AUG-1 2 20-AUG-1 2 27-AUG-1 2 27-AUG-12 Collection End Date 03-JAN-12 09-JAN-1 2 16-JAN-1 2 23-JAN-1 2 30-JAN-12 06-FEB-12 15-FEB-12 21-FEB-1 2 27-FEB-12 05-MAR-12 12-MAR-12 19-MAR-12 26-MAR-12 02-APR-1 2 09-APR-12 16-APR-12 24-APR-12 24-APR-1 2 30-APR-1 2 08-MAY-12 14-MAY-1 2 21-MAY-1 2 29-MAY-12 04-JUN-12 11-JUN-12 18-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 06-AUG-1 2 06-AUG-12 13-AUG-12 20-AUG-12 27-AUG-12 27-AUG-12 04-SEP-12 04-SEP-12 Volume m 3 Gross Beta Concentration (pCi/m 3 )

1-131 Concentration (pCi/m 3)

Duplicate Analysis 312 260 302 318 302 306 391 264 269 295 300 292 305 302 299 305 342 342 258 340 259 311 329 256 305 301 303 299 299 296 300 298 297 297 295 299 298 298 333 333 0.016 0.019 0.021 0.045 0.017 0.026 0.026 0.042 0.015 0.023 0.019 0.020 0.012 0.034 0.024 0.015 0.018 0.019 0.030 0.019 0.023 0.028 0.026 0.018 0.030 0.019 0.024 0.045 0.024 0.032 0.032 0.030 0.037 0.033 0.027 0.023 0.030 0.030 0.032 0.033

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.004 0.004 0.003 0.004 0.004 0.004 0.003 0.005 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.005 0.004 0.004 0.005 0.005 0.004 0.004 0.005 0.004 0.005 0.004 0.004 0.005 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.010 0.012 0.009 0.011 0.018 0.013 0.013 0.016 0.010 0.010 0.017 0.014 0.010 0.012 0.013 0.020 0.016 0.013 0.019 0.011 0.008 0.010 0.010 0.006 0.011 0.012 0.008 0.012 0.018 0.008 0.013 0.011 Duplicate Duplicate Duplicate Duplicate

< 0.011

< 0.011

< 0.014

< 0.020 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 9

Air Particulate and Charcoal Filters Location: 049 Collection Start Date 04-SEP-12 10-SEP-12 17-SEP-12 17-SEP-12 24-SEP-12 01-OCT-12 01-OCT-12 08-OCT-12 15-OCT-12 22-OCT-12 29-OCT-12 05-NOV-1 2 12-NOV-12 19-NOV-12 26-NOV-12 03-DEC-12 10-DEC-12 17-DEC-1 2 26-DEC-1 2 26-DEC-12 31-DEC-12 Collection End Date 10-SEP-12 17-SEP-12 24-SEP-12 24-SEP-12 01-OCT-12 08-OCT-12 08-OCT-12 15-OCT-12 22-OCT-12 29-OCT-1 2 05-NOV-12 12-NOV-12 19-NOV-12 26-NOV-12 03-DEC-12 10-DEC-12 17-DEC-1 2 26-DEC-1 2 31-DEC-12 31-DEC-12 07-JAN-13 Volume m

3 Gross Beta Concentration (pCi/m33 )

1-131 Concentration (pCilm 3)

Duplicate Analysis 263 302 305 305 297 313 313 304 298 310 310 307 299 311 291 314 299 391 211 211 307 0.025 0.023 0.020 0.021 0.040 0.030 0.034 0.039 0.032 0.028 0.059 0.026 0.064 0.057 0.059 0.034 0.055 0.051 0.044 0.036 0.049

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.005 0.004 0.004 0.004 0.005 0.004 0.005 0.005 0.005 0.004 0.005 0.004 0.005 0.005 0.005 0.004 0.005 0.004 0.006 0.006 0.005 0.006 0.016 0.006

< 0.013

< 0.018 0.015 0.011 0.012 0.011 0.011 0.011 0.015 0.009 0.008 0.018 0.009 0.019 Duplicate Duplicate Duplicate

< 0.013 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-10

Air Particulate and Charcoal Filters Location: 053 Collection Start Date 27-DEC-i 1 03-JAN-12 09-JAN-12 16-JAN-1 2 23-JAN-1 2 30-JAN-12 06-FEB-1 2 15-FEB-12 21-FEB-12 21-FEB-1 2 27-FEB-12 05-MAR-12 12-MAR-1 2 19-MAR-1 2 26-MAR-1 2 02-APR-12 09-APR-12 16-APR-12 24-APR-1 2 30-APR-12 08-MAY-12 14-MAY-12 21-MAY-12 21 -MAY-1 2 29-MAY-1 2 04-JUN-12 11-JUN-12 18-JUN-12 18-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 06-AUG-12 13-AUG-12 20-AUG-12 27-AUG-1 2 04-SEP-1 2 Collection End Date 03-JAN-1 2 09-JAN-1 2 16-JAN-12 23-JAN-12 30-JAN-12 06-FEB-12 15-FEB-1 2 21-FEB-1 2 27-FEB-12 27-FEB-12 05-MAR-12 12-MAR-12 19-MAR-1 2 26-MAR-1 2 02-APR-12 09-APR-12 16-APR-12 24-APR-1 2 30-APR-1 2 08-MAY-12 14-MAY-1 2 21 -MAY-1 2 29-MAY-1 2 29-MAY-1 2 04-JUN-12 11-JUN-12 18-JUN-12 25-JUN-12 25-JUN-12 02-JUL-12 09-JUL-12 16-JUL-12 23-JUL-12 30-JUL-12 06-AUG-12 13-AUG-12 20-AUG-12 27-AUG-12 04-SEP-12 10-SEP-12 Volume m

3 Gross Beta Concentration (pCilm3 )

1-131 Concentration (pCilm 3)

Duplicate Analysis 305 259 296 309 305 306 386 254 261 261 291 304 293 302 299 303 298 351 254 340 256 307 330 330 257 300 304 299 299 300 300 297 295 298 295 299 297 300 338 260 0.023 0.020 0.021 0.039 0.014 0.018 0.025 0.034 0.011 0.015 0.018 0.020 0.023 0.012 0.025 0.020 0.016 0.021 0.028 0.016 0.024 0.027 0.026 0.026 0.017 0.024 0.019 0.020 0.018 0.043 0.021 0.031 0.027 0.024 0.031 0.026 0.024 0.030 0.032 0.025

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.004 0.004 0.004 0.004 0.003 0.004 0.003 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.005 0.003 0.005 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.005 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.010 0.012 0.009 0.011 0.018 0.013 0.013 0.017 0.010 0.011 0.017 0.014 0.010 0.012 0.012 0.021 0.016 0.013 0.019 0.011 0.008 0.010 0.010 0.006 0.011 0.012 0.008 0.012 0.018 0.009 0.013 0.011 0.011 0.011 0.014 0.020 0.006 Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 11

Air Particulate and Charcoal Filters Location: 053 Collection Start Date 10-SEP-12 17-SEP-12 24-SEP-12 01-OCT-12 08-OCT-12 15-OCT-12 15-OCT-1 2 22-OCT-1 2 29-OCT-12 05-NOV-12 12-NOV-12 19-NOV-12 26-NOV-1 2 03-DEC-12 10-DEC-12 17-DEC-12 26-DEC-1 2 31-DEC-1 2 Collection End Date 17-SEP-12 24-SEP-1 2 01-OCT-12 08-OCT-12 15-OCT-12 22-OCT-12 22-OCT-1 2 29-OCT-1 2 05-NOV-1 2 12-NOV-12 19-NOV-12 26-NOV-1 2 03-DEC-12 10-DEC-12 17-DEC-12 26-DEC-1 2 31-DEC-1 2 07-JAN-1 3 Volume m

3 Gross Beta Concentration (pCi/m3 )

1-131 Concentration (pCi/m 3)

Duplicate Analysis 299 315 294 314 291 304 304 307 299 307 292 299 300 308 301 386 188 304 0.020 0.023 0.039 0.025 0.039 0.030 0.030 0.028 0.054 0.029 0.064 0.052 0.049 0.032 0.056 0.053 0.042 0.052

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-0.004 0.004 0.005 0.004 0.005 0.004 0.004 0.004 0.005 0.004 0.005 0.005 0.005 0.004 0.005 0.004 0.007 0.005

< 0.016

< 0.006

< 0.013

< 0.018

< 0.015

< 0.010 Duplicate 0.012 0.011 0.011 0.011 0.015 0.009 0.008 0.018 0.009 0.021 0.013 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-12

Quarterly Air Particulate - Gamma Location:

002 02-APR-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 02-JUL-12 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 01-OCT-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 31-DEC-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 Concentration (pCilm3 )

0.073+/-

0.010 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.105+/-

0.015 0.001 0.001 0.002 0.001 0.002 0.001 0.001 0.001 Concentration (pCilm3 )

0.097+/-

0.013 0.001 0.001 0.002 0.001 0.001 0.001 0.001 0.001 Concentration (pCilm3 )

0.056+/-

0.014 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001

Quarterly Air Particulate - Gamma Location:

018 02-APR-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 02-JUL-12 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 01-OCT-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 31-DEC-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 Concentration (pCi/m 3 )

0.072+/-

0.016 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.096+/-

0.015 0.001 0.001 0.002 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.089+/-

0.016 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.061+/-

0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001

Quarterly Air Particulate - Gamma Location:

032 02-APR-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 02-JUL-12 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 01-OCT-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 31-DEC-12 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 Concentration (pCi/m 3 )

0.074+/-

0.013 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCilm3 )

0.098+/-

0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.087+/-

0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.059+/-

0.014 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001

Quarterly Air Particulate - Gamma Location:

037 02-APR-I 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 02-JUL-12 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 01-OCT-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 31-DEC-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 Concentration (pCi/m 3 )

0.088+/-

0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.103+/-

0.014 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCilm3 )

0.096+/-

0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCilm3 )

0.052+/-

0.012 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001

Quarterly Air Particulate - Gamma Location:

049 02-APR-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 02-JUL-12 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 01-OCT-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 31-DEC-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 Concentration (pCilm 3 )

0.077+/-

0.012 0.001 0.001 0.001 0.001 0.002 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.103+/-

0.016 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.094+/-

0.016 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.059+/-

0.012 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001

Quarterly Air Particulate - Gamma Location:

053 02-APR-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 02-JUL-I 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 01-OCT-1 2 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 31-DEC-12 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 Concentration (pCi/mr3 )

0.082+/-

0.014 0.001 0.001 0.002 0.001 0.002 0.001 0.001 0.001 Concentration (pCi/m 3 )

0.113+/-

0.017 0.001 0.001 0.002 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/mr3 )

0.098+/-

0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/mr3 )

0.065+/-

0.012 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001

Exposure Pathway - Waterborne Surface Water Location JRR Collection Date 23-JAN-1 2 23-JAN-1 2 23-JAN-12 23-JAN-12 23-JAN-12 23-JAN-1 2 23-JAN-1 2 23-JAN-1 2 23-JAN-12 23-JAN-12 23-JAN-12 27-FEB-1 2 27-FEB-1 2 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 26-MAR-12 26-MAR-12 26-MAR-1 2 26-MAR-1 2 26-MAR-1 2 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 16-APR-12 16-APR-1 2 16-APR-12 16-APR-12 16-APR-12 16-APR-12 Nuclide Gamma Spectrum & H-3 Concentration (pCi/Liter)

Duplicate Analysis MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-1 40 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 2.3 3.7 5.8 1.8 4.7 4.0 4.0 3.6 3.8 3.1 146.0 1.7 2.1 3.4 2.7 2.8 1.7 2.8 2.5 2.7 2.2 141.0 194.0 2.9 2.1 4.1 3.0 2.7 2.4 3.6 3.4 3.1 3.0 152.0 2.8 2.6 4.9 1.8 3.7 4.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-19

Exposure Pathway - Waterborne Surface Water Location JRR Collection Date 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 20-AUG-12 Nuclide 1-131 CS-134 CS-137 BA-LA-1 40 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-1 40 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-1 40 H-3 MN-54 Gamma Spectrum & H-3 Concentration (pCi/Liter)

Duplicate Analysis 4.3 2.5 3.2 2.4 150.0 4.0 3.4 3.6 4.2 4.8 3.1 5.7 3.6 2.9 4.6 148.0 175.0 3.1 3.1 6.9 2.6 5.5 3.5 5.7 2.8 3.2 2.6 140.0 3.0 3.7 5.2 1.8 4.7 3.1 5.5 2.0 2.9 3.9 156.0 6.1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-20

Exposure Pathway - Waterborne Surface Water Location JRR Collection Date 20-AUG-12 20-AUG-12 20-AUG-1 2 20-AUG-1 2 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 17-SEP-1 2 17-SEP-1 2 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-1 2 17-SEP-1 2 29-OCT-1 2 29-OCT-12 29-OCT-12 29-OCT-12 29-OCT-12 29-OCT-12 29-OCT-12 29-OCT-1 2 29-OCT-1 2 29-OCT-1 2 29-OCT-1 2 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 Nuclide Gamma Spectrum & H-3 Concentration (pCi/Liter)

Duplicate Analysis CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 5.3 6.0 4.5 4.1 3.6 4.9 4.1 3.2 7.1 150.0 176.0 2.9 1.7 5.5 2.8 4.6 2.9 5.0 2.3 2.1 2.9 154.0 4.3 2.2 6.0 3.5 4.4 3.1 5.9 3.6 3.0 2.5 151.0 3.8 3.1 3.5 3.6 4.2 3.3 4.8 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 21

Exposure Pathway - Waterborne Surface Water Location JRR Collection Date 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-1 2 10-DEC-1 2 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 Nuclide Gamma Spectrum & H-3 Concentration (pCi/Liter)

Duplicate Analysis CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BA-LA-140 H-3 2.9 3.4 2.7 142.0 167.0 3.6 2.7 4.8 4.0 4.2 3.7 6.2 3.1 4.0 2.7 150.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-22

Exposure Pathway - Waterborne Surface Water Location SP Collection Date 23-JAN-1 2 23-JAN-12 23-JAN-12 23-JAN-12 23-JAN-12 23-JAN-12 23-JAN-1 2 23-JAN-1 2 23-JAN-1 2 23-JAN-12 23-JAN-12 27-FEB-1 2 27-FEB-1 2 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-1 2 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 26-MAR-12 26-MAR-12 26-MAR-1 2 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-1 2 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 Nuclide Gamma Spectrum & H-3 Concentration (pCi/Liter)

Duplicate Analysis MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 10,037+-

11,290+-

12,151+1 2.5 4.1 5.4 2.6 3.4 3.8 4.3 2.3 4.0 3.3 296.0 3.4 3.4 8.5 3.5 1.5 3.2 3.9 4.0 2.6 4.6 312.0 175.0 2.4 2.4 4.5 1.8 2.2 1.7 2.5 2.7 2.7 2.1 325.0 1.9 1.7 4.9 1.5 3.5 1.7 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 23

Exposure Pathway - Waterborne Surface Water Location SP Collection Date 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 07-MAY-12 07-MAY-1 2 07-MAY-1 2 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-1 2 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 11-JUN-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 23-JUL-12 20-AUG-1 2 Nuclide Gamma Spectrum & H-3 Concentration (pCi/Liter)

Duplicate Analysis 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-137 BA-LA-140 H-3 MN-54 12,545

+/-

11,622+-

11,619+1 12,145+-

2.5 3.2 2.9 2.3 333.0 3.7 2.1 4.1 2.4 4.6 4.3 7.3 3.8 2.8 3.5 319.0 180.0 2.3 1.9 3.9 2.5 1.8 2.0 3.8 1.7 2.6 2.3 301.0 2.2 2.5 3.8 1.7 4.4 1.8 3.8 2.0 2.6 2.8 331.0 3.5 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-24

Exposure Pathway - Waterborne Surface Water Location SP Collection Date 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-1 2 20-AUG-1 2 17-SEP-12 17-SEP-1 2 17-SEP-1 2 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 29-OCT-1 2 29-OCT-1 2 29-OCT-12 29-OCT-1 2 29-OCT-12 29-OCT-12 29-OCT-12 Nuclide Gamma Spectrum & H-3 Concentration (pCi/Liter)

Duplicate Analysis CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 1-131 1-131 CS-134 CS-134 CS-137 CS-137 BA-LA-140 BA-LA-140 H-3 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 10,735+1 10,817+1 10,909+-

4.1 9.7 5.7 6.6 5.4 6.5 4.6 5.2 5.4 308.0 174.0 3.8 2.1 2.9 2.9 3.4 4.8 4.1 3.2 4.6 7.0 4.8 3.8 5.8 6.0 4.0 2.7 6.4 3.8 5.0 3.3 310.0 311.0 3.2 3.0 4.9 4.1 4.9 2.4 6.5 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-25

Exposure Pathway - Waterborne Surface Water Location SP Collection Date 29-OCT-12 29-OCT-12 29-OCT-12 29-OCT-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 10-DEC-12 Nuclide Gamma Spectrum & H-3 Concentration (pCi/Liter)

Duplicate Analysis CS-1 34 CS-1 37 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BA-LA-140 H-3 10,971

+/-

11,404+-

11,791+1 3.1 3.9 3.0 312.0 3.2 4.3 7.6 4.6 5.7 3.2 6.7 4.7 4.4 2.3 297.0 158.0 3.0 1.8 3.0 3.1 3.6 3.4 6.4 3.8 4.0 3.5 317.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-26

Exposure Pathway - Waterborne Ground Water Location B-12 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-1 2 27-FEB-1 2 27-FEB-1 2 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-1 2 07-MAY-12 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 20-AUG-1 2 20-AUG-12 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-12 20-AUG-12 14-NOV-12 14-NOV-1 2 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 3.3 3.9 4.9 2.3 3.9 2.1 3.8 1.9 1.6 141.0 0.293 3.0 2.5 4.5 2.3 2.5 2.5 2.0 2.7 2.8 148.0 0.349 3.8 2.6 4.1 1.9 4.1 4.1 2.8 4.6 3.6 150.0 0.307 3.2 1.5 5.1 4.2 3.6 3.2 2.9 4.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-27

Exposure Pathway - Waterborne Ground Water Location B-12 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 14-NOV-12 14-NOV-12 14-NOV-1 2 BA-LA-140 H-3 1-131 (CHEM) 2.9 142.0 0.287 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-28

Exposure Pathway - Waterborne Ground Water Location C-10 Collection Date 27-FEB-1 2 27-FEB-1 2 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-12 07-MAY-1 2 07-MAY-12 07-MAY-12 07-MAY-1 2 07-MAY-1 2 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 Nuclide MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 Concentration (pCi/Liter)

Duplicate Analysis 2.2 2.5 4.6 2.3 2.6 2.1 2.1 2.8 1.3 141.0 0.178 2.2 2.0 4.8 2.7 3.7 2.3 3.0 2.9 2.3 148.0 0.356 2.2 2.5 2.8 3.4 3.6 2.6 2.3 2.1 2.3 150.0 0.243 3.5 3.9 7.3 2.6 4.1 2.5 3.3 3.1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

29

Exposure Pathway - Waterborne Ground Water Location C-10 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 14-NOV-12 14-NOV-12 14-NOV-12 BA-LA-140 H-3 1-131 (CHEM) 3.1 142.0 0.445 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-30

Exposure Pathway - Waterborne Ground Water Location C-49 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-1 2 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 07-MAY-1 2 07-MAY-1 2 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-1 2 07-MAY-12 07-MAY-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-12 20-AUG-12 20-AUG-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 4.1 4.0 3.7 2.2 4.6 4.6 3.0 2.7 4.0 141.0 0.244 3.6 3.9 5.6 2.9 6.0 2.3 3.6 5.0 1.6 148.0 0.321 3.2 3.7 6.2 3.2 9.6 2.3 3.4 4.1 3.4 150.0 0.48 1.9 1.6 5.2 2.5 4.4 3.6 2.1 2.1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-31

Exposure Pathway - Waterborne Ground Water Location C-49 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 14-NOV-12 14-NOV-12 14-NOV-12 BA-LA-140 H-3 1-131 (CHEM) 3.6 142.0 0.461 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-32

Exposure Pathway - Waterborne Ground Water Location F-1 Collection Date Nuclide Concentration (pCilLiter)

Duplicate Analysis 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-1 2 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 07-MAY-1 2 07-MAY-1 2 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-1 2 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 2.7 1.6 2.6 1.9 4.4 2.5 2.2 3.0 2.0 141.0 0.177 1.8 1.5 3.0 0.9 3.9 3.0 2.8 3.0 1.3 148.0 0.44 2.7 4.1 7.5 1.9 6.7 3.0 2.4 3.2 4.1 150.0 0.242 3.2 2.4 5.2 2.6 2.6 3.3 3.3 3.4 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

33

Exposure Pathway - Waterborne Ground Water Location F-1 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 14-NOV-12 14-NOV-12 14-NOV-12 BA-LA-140 H-3 1-131 (CHEM) 2.7 142.0 0.437 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-34

Exposure Pathway - Waterborne Ground Water Location G-2 Collection Date Nuclide Concentration (pCilLiter)

Duplicate Analysis 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-1 2 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 07-MAY-12 07-MAY-1 2 07-MAY-1 2 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-1 2 07-MAY-1 2 07-MAY-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-1 2 20-AUG-1 2 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-1 2 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 3.0 2.0 7.9 3.5 7.5 2.6 3.2 2.3 4.1 141.0 0.35 2.9 3.9 5.7 4.0 6.7 3.6 2.9 4.1 3.3 148.0 0.453 3.4 2.7 4.8 3.7 8.1 5.5 3.5 2.4 2.4 150.0 0.344 2.8 2.4 5.9 2.5 2.6 3.9 2.5 2.9 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

35

Exposure Pathway - Waterborne Ground Water Location G-2 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 14-NOV-12 14-NOV-12 14-NOV-12 BA-LA-140 H-3 1-131 (CHEM) 3.7 142.0 0.417 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-36

Exposure Pathway - Waterborne Ground Water Location J-1 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-1 2 27-FEB-1 2 27-FEB-12 27-FEB-12 27-FEB-12 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-12 07-MAY-1 2 07-MAY-12 07-MAY-12 07-MAY-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-1 2 20-AUG-1 2 20-AUG-12 20-AUG-1 2 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 3.5 3.3 5.4 2.3 7.2 5.1 2.7 2.4 2.5 141.0 0.241 2.1 2.7 3.8 1.8 5.3 2.0 2.8 2.9 2.6 148.0 0.391 3.8 2.7 3.4 4.6 5.1 4.7 6.3 4.8 4.7 150.0 0.374 2.2 2.6 3.2 2.6 5.2 5.2 2.6 3.2 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-37

Exposure Pathway - Waterborne Ground Water Location J-1 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 14-NOV-12 14-NOV-12 14-NOV-12 BA-LA-140 H-3 1-131 (CHEM) 4.3 142.0 0.39 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

38

Exposure Pathway - Waterborne Ground Water Location J-2 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-1 2 07-MAY-1 2 07-MAY-12 07-MAY-12 07-MAY-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 20-AUG-1 2 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 CS-134 CS-1 34 CS-1 37 CS-1 37 BA-LA-140 BA-LA-140 H-3 1.8 2.2 6.0 1.7 6.2 2.5 2.1 2.1 2.3 141.0 0.237 1.8 2.8 3.5 2.5 5.4 2.9 2.7 3.0 1.9 148.0 0.338 2.9 4.3 3.6 2.2 4.1 6.5 2.7 3.3 5.8 8.3 2.5 4.1 3.1 3.4 2.9 4.7 2.4 4.2 150.0 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-39

Exposure Pathway - Waterborne Ground Water Location J-2 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 20-AUG-12 20-AUG-12 20-AUG-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-1 2 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 H-3 1-131 (CHEM) 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM) 150.0 0.343 0.457 2.5 1.5 4.8 1.6 4.7 2.4 2.4 3.2 3.0 142.0 0.399 Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-40

Exposure Pathway - Waterborne Ground Water Location L-49 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-1 2 27-FEB-1 2 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 27-FEB-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-1 2 07-MAY-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-12 20-AUG-1 2 20-AUG-12 20-AUG-1 2 20-AUG-12 20-AUG-12 20-AUG-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 2.6 3.0 3.4 1.8 4.1 3.4 2.8 3.4 3.1 141.0 0.33 2.5 1.8 3.6 0.8 5.2 2.8 2.8 3.1 2.2 148.0 0.313 2.8 2.8 3.5 2.3 4.9 2.7 2.7 3.0 1.0 150.0 0.442 2.2 1.1 3.2 2.7 3.3 2.7 2.4 2.6 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-41

Exposure Pathway - Waterborne Ground Water Location L-49 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 14-NOV-12 14-NOV-12 14-NOV-12 BA-LA-140 H-3 1-131 (CHEM) 2.3 142.0 0.259 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

42

Exposure Pathway - Waterborne Drinking Water Location BW-15 Collection Date 06-FEB-1 2 06-FEB-1 2 06-FEB-1 2 06-FEB-1 2 06-FEB-12 06-FEB-12 06-FEB-12 06-FEB-12 06-FEB-12 06-FEB-12 06-FEB-12 05-MAR-12 05-MAR-12 05-MAR-12 05-MAR-12 05-MAR-1 2 05-MAR-1 2 05-MAR-1 2 05-MAR-12 05-MAR-1 2 05-MAR-1 2 05-MAR-1 2 02-APR-1 2 02-APR-1 2 02-APR-1 2 02-APR-1 2 02-APR-1 2 02-APR-12 02-APR-12 02-APR-12 02-APR-12 02-APR-12 02-APR-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-1 2 07-MAY-12 Nuclide Concentration (pCi/Liter)

Duplicate Analysis MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 3.346 +/-

3.154 +/-

2.513 +/-

3.3 4.1 5.4 3.4 4.1 2.7 4.5 3.0 5.1 0.714 0.323 2.7 1.7 3.7 1.4 1.7 2.4 1.8 2.7 1.4 0.701 0.257 2.8 3.2 5.9 2.0 5.8 2.3 3.0 2.6 1.8 0.654 0.283 1.9 1.5 3.8 1.0 2.7 2.3 3.1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

43

Exposure Pathway - Waterborne Drinking Water Location BW-15 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-1 2 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 06-AUG-12 06-AUG-12 06-AUG-12 06-AUG-12 06-AUG-12 06-AUG-1 2 06-AUG-1 2 06-AUG-1 2 06-AUG-1 2 06-AUG-12 06-AUG-1 2 04-SEP-12 04-SEP-12 04-SEP-12 CS-1 37 BA-LA-1 40 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-1 40 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 MN-54 CO-58

< 3.0 3.388 +/-

2.6 0.709 0.303 3.6 2.3

< 4.8

< 2.6

< 2.7

< 1.7

< 2.7

< 3.1

< 1.3 2.076+/- 0.608

< 0.303

< 3.0

< 1.8

< 3.9

< 2.4

< 3.3

< 2.2

< 1.9 1.834+/-

2.3 2.2 0.6 0.302

< 2.8

< 3.1

< 6.6

< 1.9

< 5.1

< 2.3

< 3.2 1.239+/-

4.3 2.8 0.556 0.168 3.2 2.1 2.0 GRAB 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-44

Exposure Pathway - Waterborne Drinking Water Location BW-15 Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 05-NOV-12 05-NOV-12 05-NOV-12 05-NOV-1 2 05-NOV-1 2 05-NOV-12 05-NOV-1 2 05-NOV-1 2 05-NOV-12 05-NOV-12 GRAB GRAB GRAB GRAB GRAB GRAB GRAB GRAB GRAB GRAB CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 CS-134 CS-134 CS-137 CS-137 BA-LA-140 BA-LA-140 GROSS BETA GROSS BETA 1-131 (CHEM) 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 BA-LA-1 40 GROSS BETA

< 1.8

< 7.6

< 2.4

< 3.1

< 1.8

< 7.6

< 3.5

< 4.0

< 1.5

< 3.4

< 2.6

< 3.8

< 2.8

< 3.7 3.702 +/-

4.021 +/-

2.9 0.739 0.781 0.304 0.279 4.2 3.3 5.4 3.3 5.8 2.6 4.6 3.3 5.6 0.713 0.326 3.8 3.150 +/-

< 2.9

< 4.7

< 3.6

< 7.0

< 4.6

< 2.5

< 5.4

< 2.9 2.935 +/- 0.679 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-45

Exposure Pathway - Waterborne Drinking Water Location BW-1 5 Collection Date 05-NOV-12 03-DEC-12 03-DEC-12 03-DEC-12 03-DEC-12 03-DEC-1 2 03-DEC-1 2 03-DEC-1 2 03-DEC-1 2 03-DEC-1 2 03-DEC-1 2 03-DEC-12 07-JAN-13 07-JAN-13 07-JAN-13 07-JAN-13 07-JAN-13 07-JAN-13 07-JAN-13 07-JAN-13 07-JAN-1 3 07-JAN-1 3 07-JAN-1 3 Nuclide Concentration (pCi/Liter)

Duplicate Analysis 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 BA-LA-1 40 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM) 2.387 +/-

2.988 +/-

0.494 3.1 2.2 5.2 3.0 5.5 2.2 2.5 3.8 2.2 0.656 0.409 2.4 2.1 3.7 2.4 1.5 2.9 2.3 2.4 2.0 0.715 0.286 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

46

Exposure Pathway - Waterborne Drinking Water Location 1O-DW Collection Date 06-FEB-12 06-FEB-12 06-FEB-12 06-FEB-12 06-FEB-12 06-FEB-12 06-FEB-12 06-FEB-12 06-FEB-1 2 06-FEB-12 06-FEB-12 05-MAR-1 2 05-MAR-12 05-MAR-12 05-MAR-12 05-MAR-12 05-MAR-12 05-MAR-12 05-MAR-12 05-MAR-12 05-MAR-12 05-MAR-12 02-APR-12 02-APR-1 2 02-APR-1 2 02-APR-12 02-APR-1 2 02-APR-1 2 02-APR-1 2 02-APR-1 2 02-APR-1 2 02-APR-1 2 02-APR-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 07-MAY-12 Nuclide Concentration (pCi/Liter)

Duplicate Analysis MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134

< 2.8

< 2.2 2.906+/-

3.565 +/-

2.595 +/-

4.4 1.2 2.7 3.0 2.1 2.0 2.8 0.694 0.336 2.5 2.1 2.7 1.0 1.5 2.7 2.2 2.1 3.1 0.736 0.275 2.5 3.3 3.0 1.6 4.6 2.6 2.5 2.4 3.8 0.682 0.378 3.6 1.6 2.5 2.6 1.7 2.7 1.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-47

Exposure Pathway - Waterborne Drinking Water Location 1O-DW Collection Date 07-MAY-1 2 07-MAY-1 2 07-MAY-12 07-MAY-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 04-JUN-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 02-JUL-12 06-AUG-12 06-AUG-12 06-AUG-12 06-AUG-12 06-AUG-12 06-AUG-12 06-AUG-12 06-AUG-12 06-AUG-12 06-AUG-1 2 06-AUG-1 2 04-SEP-12 04-SEP-1 2 04-SEP-12 Nuclide Concentration (pCi/Liter)

Duplicate Analysis CS-1 37 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 3.237+/-

2.9 1.3 0.705 0.318

< 1.6

< 1.7 2.788+/-

3.000+/-

2.062+/-

2.7 1.2 4.2 3.5 2.4 2.9 1.4 0.673 0.3 2.0 2.4 2.6 1.6 3.1 3.0 2.3 2.7 1.9 0.7 0.319 2.9 3.3 7.8 3.0 2.4 2.2 3.5 3.3 3.6 0.626 0.143 2.6 3.5 7.5 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-48

Exposure Pathway - Waterborne Drinking Water Location IO-DW Collection Date 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 04-SEP-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 01-OCT-12 05-NOV-12 05-NOV-12 05-NOV-12 05-NOV-12 05-NOV-12 05-NOV-12 05-NOV-12 05-NOV-12 05-NOV-12 05-NOV-12 05-NOV-1 2 03-DEC-12 03-DEC-1 2 03-DEC-1 2 03-DEC-1 2 03-DEC-1 2 03-DEC-12 03-DEC-1 2 03-DEC-12 03-DEC-12 03-DEC-12 Nuclide Concentration (pCi/Liter)

Duplicate Analysis CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 BA-LA-140 GROSS BETA 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-1 40 GROSS BETA

< 2.4

< 6.6

< 3.8

< 3.6

< 3.3

< 3.8 3.046 +/- 0.727 0.194 1.9 2.9 4.5 1.9 2.3 1.9 2.6 3.2 3.0 0.749 0.321 3.749 +/-

< 3.2

< 1.5

< 2.8

< 1.8

< 5.0

< 1.9

< 2.4

< 2.4

< 1.9 3.329+/- 0.711

< 0.36

< 2.6

< 4.0

< 7.7

< 3.5

< 6.5

< 2.3

< 3.5 3.003 +/-

4.8 2.6 0.694 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-49

Exposure Pathway - Waterborne Drinking Water Location 10-DW Collection Date Nuclide Concentration (pCi/Liter)

Duplicate Analysis 03-DEC-12 07-JAN-13 07-JAN-13 07-JAN-13 07-JAN-13 07-JAN-13 07-JAN-1 3 07-JAN-1 3 07-JAN-1 3 07-JAN-1 3 07-JAN-13 07-JAN-13 1-131 (CHEM)

MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-1 40 GROSS BETA 1-131 (CHEM) 2.408 +/-

0.414 2.1 2.5 1.8 1.7 3.9 1.7 2.1 2.9 1.6 0.635 0.313 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

50

Exposure Pathway - Waterborne Drinking Water Quarterly Tritium Analysis Location BW-15 Collection Date 02-APR-12 02-JUL-12 01-OCT-12 07-JAN-13 Nuclide Concentration (pCi/Liter)

Duplicate Analysis H-3 H-3 H-3 H-3

< 143

< 148

< 150

< 137 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-51

Exposure Pathway - Waterborne Drinking Water Quarterly Tritium Analysis Location IO-DW Collection Date 02-APR-1 2 02-JUL-12 01-OCT-12 07-JAN-1 3 07-JAN-1 3 Nuclide H-3 H-3 H-3 H-3 H-3 Concentration (pCi/Liter) 222 +/- 83

< 148

< 150

< 137

< 137 Duplicate Analysis Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

52

Exposure Pathway - Waterborne Shoreline Sediment Location DC Collection Date 02-MAY-12 02-MAY-12 02-MAY-1 2 02-MAY-1 2 02-MAY-1 2 02-MAY-12 02-MAY-12 02-MAY-12 29-NOV-12 29-NOV-1 2 29-NOV-12 29-NOV-1 2 29-NOV-1 2 29-NOV-1 2 29-NOV-12 29-NOV-12 29-NOV-12 29-NOV-12 29-NOV-1 2 29-NOV-12 29-NOV-1 2 29-NOV-1 2 29-NOV-12 29-NOV-12 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 K-40 K-40 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 CS-134 CS-134 CS-137 CS-137 Gamma Spectrum Concentration (pCi/Kg Dry) 8,464.3 +/-

914.7 41.1 49.6 81.1 17.2 104.5 35.2 48.2 6,047.9 +/-

384.0 6,074.1 +/-

461.5 17.0 19.5 16.0 19.0 23.9 47.3 7.2 9.5 33.9 33.6 14.6 13.1 12.9 17.1 Duplicate Analysis Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-53

Exposure Pathway - Waterborne Shoreline Sediment Location EEA Collection Date 29-MAY-12 29-MAY-1 2 29-MAY-1 2 29-MAY-1 2 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 Gamma Spectrum Concentration (pCi/Kg Dry) 8,620.8 +/-

993.9 49.6 20.8 65.0 28.1 73.1 36.3 234.3 +/-

58.9 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-54

Exposure Pathway - Waterborne Shoreline Sediment Location JRR Collection Date 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-1 2 02-MAY-1 2 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 Gamma Spectrum Concentration (pCi/Kg Dry)

Duplicate Analysis 10,239.0 +/-

6,356.2+-

678.5 27.7 30.4 67.3 19.0 44.4 15.5 24.7 415.4 15.1 17.8 46.9 8.7 41.0 14.2 16.9 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 55

Exposure Pathway - Waterborne Shoreline Sediment Location SC Collection Date 03-OCT-12 03-OCT-12 03-OCT-1 2 03-OCT-1 2 03-OCT-1 2 03-OCT-1 2 03-OCT-12 03-OCT-12 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 Gamma Spectrum Concentration (pCilKg Dry) 12,147.0 +/-.

772.7 26.8 29.4 39.7 28.0 52.6 20.7 75.8 +/-

29.2 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-56

Exposure Pathway - Ingestion Fish Location CCL Collection Date 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-1 2 22-MAY-12 22-MAY-1 2 22-MAY-1 2 22-MAY-1 2 22-MAY-1 2 22-MAY-1 2 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-1 2 22-MAY-12 22-MAY-1 2 22-MAY-12 22-MAY-12 22-MAY-1 2 22-MAY-1 2 22-MAY-1 2 22-MAY-1 2 22-MAY-12 22-MAY-12 Sample Nuclide Description COMMON CARP K-40 COMMON CARP MN-54 COMMON CARP CO-58 COMMON CARP FE-59 COMMON CARP CO-60 COMMON CARP ZN-65 COMMON CARP 1-131 COMMON CARP CS-1 34 COMMON CARP CS-1 37 COMMON CARP H-3 FRESHWATER DRUM K-40 FRESHWATER DRUM MN-54 FRESHWATER DRUM CO-58 FRESHWATER DRUM FE-59 FRESHWATER DRUM CO-60 FRESHWATER DRUM ZN-65 FRESHWATER DRUM 1-131 FRESHWATER DRUM CS-134 FRESHWATER DRUM CS-137 FRESHWATER DRUM H-3 SMALLMOUTH BASS K-40 SMALLMOUTH BASS K-40 SMALLMOUTH BASS MN-54 SMALLMOUTH BASS MN-54 SMALLMOUTH BASS CO-58 SMALLMOUTH BASS CO-58 SMALLMOUTH BASS FE-59 SMALLMOUTH BASS FE-59 SMALLMOUTH BASS CO-60 SMALLMOUTH BASS CO-60 SMALLMOUTH BASS ZN-65 SMALLMOUTH BASS ZN-65 SMALLMOUTH BASS I-131 SMALLMOUTH BASS I-131 SMALLMOUTH BASS CS-1 34 SMALLMOUTH BASS CS-134 SMALLMOUTH BASS CS-137 SMALLMOUTH BASS CS-137 SMALLMOUTH BASS H-3 SMALLMOUTH BASS H-3 SMALLMOUTH BUFFALO K-40 Gamma Spectrum & H-3 Concentration (pCilKg Wet)

Duplicate Analysis 3,018.2 +/-

8,370.0 +/-

3,i68.0 +1-8,i5i.0 +/-

3,677.2 +/-

3,528.9 +/-

8,850.0 +/-

8,948.0 +/-

2,990.3 +1-361.0 9.5 12.0 19.2 7.1 24.6 13.0 8.9 17.4 240.0 384.9 9.7 9.8 21.8 11.2 27.8 19.9 14.7 9.0 239.0 392.4 372.8 13.5 10.9 7.7 13.5 30.3 21.8 12.3 7.6 20.4 27.3 13.7 12.4 13.6 9.8 13.0 13.8 248.0 250.0 407.2 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-57

Exposure Pathway - Ingestion Fish Location CCL Collection Date 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-1 2 22-MAY-12 22-MAY-1 2 22-MAY-1 2 17-OCT-1 2 17-OCT-1 2 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-1 2 17-OCT-1 2 17-OCT-1 2 17-OCT-1 2 17-OCT-12 17-OCT-1 2 17-OCT-1 2 17-OCT-12 17-OCT-12 17-OCT-12 Sample Nuclide Description SMALLMOUTH BUFFALO MN-54 SMALLMOUTH BUFFALO CO-58 SMALLMOUTH BUFFALO FE-59 SMALLMOUTH BUFFALO CO-60 SMALLMOUTH BUFFALO ZN-65 SMALLMOUTH BUFFALO 1-131 SMALLMOUTH BUFFALO CS-134 SMALLMOUTH BUFFALO CS-137 SMALLMOUTH BUFFALO H-3 BLUE CATFISH K-40 BLUE CATFISH MN-54 BLUE CATFISH CO-58 BLUE CATFISH FE-59 BLUE CATFISH CO-60 BLUE CATFISH ZN-65 BLUE CATFISH 1-131 BLUE CATFISH CS-134 BLUE CATFISH CS-137 BLUE CATFISH H-3 COMMON CARP K-40 COMMON CARP MN-54 COMMON CARP CO-58 COMMON CARP FE-59 COMMON CARP CO-60 COMMON CARP ZN-65 COMMON CARP 1-131 COMMON CARP CS-1 34 COMMON CARP CS-137 COMMON CARP H-3 WALLEYE K-40 WALLEYE MN-54 WALLEYE CO-58 WALLEYE FE-59 WALLEYE CO-60 WALLEYE ZN-65 WALLEYE 1-131 WALLEYE CS-134 WALLEYE CS-137 WALLEYE H-3 WHITE BASS K-40 WHITE BASS MN-54 Gamma Spectrum & H-3 Concentration (pCi/Kg Wet)

Duplicate Analysis 8,116.0 +/-

3,162.7 +1-7,269.0 +/-

3,104.0 +1-7,670.0 +1-3,547.3 +1-6,808.0 +1-2,837.2 +1-12.6 16.7 25.6 13.6 31.4 23.3 17.0 16.8 225.0 317.8 12.4 10.8 29.4 7.7 30.3 54.3 7.8 13.3 235.0 338.9 8.6 9.0 25.8 13.7 14.4 46.3 4.3 7.2 235.0 317.9 12.6 11.6 37.8 11.1 13.6 42.3 11.0 14.1 226.0 309.1 11.6 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-58

Exposure Pathway - Ingestion Fish Location CCL Collection Date 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-1 2 17-OCT-1 2 17-OCT-1 2 17-OCT-1 2 17-OCT-1 2 17-OCT-1 2 17-OCT-1 2 17-OCT-1 2 17-OCT-1 2 17-OCT-12 17-OCT-12 17-OCT-12 17-OCT-12 Sample Description Nuclide Gamma Spectrum & H-3 Concentration (pCi/Kg Wet)

Duplicate Analysis WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE BASS BASS BASS BASS BASS BASS BASS BASS CRAPPIE CRAPPIE CRAPPIE CRAPPIE CRAPPIE CRAPPIE CRAPPIE CRAPPIE CRAPPIE CRAPPIE CO-58 FE-59 CO-60 ZN-65 1-131 CS-134 CS-137 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 1-131 CS-1 34 CS-137 H-3 7,122.0 +/-

2,981.2 +/-

7,099.0 +/-

7.8 26.5 11.4 24.4 66.5 10.8 13.5 231.0 311.1 13.0 11.6 16.9 5.3 26.0 51.7 11.0 13.7 232.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-59

Exposure Pathway - Ingestion Fish Location JRR Collection Date 22-MAY-12 22-MAY-1 2 22-MAY-1 2 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-1 2 22-MAY-1 2 22-MAY-1 2 22-MAY-12 22-MAY-1 2 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-1 2 22-MAY-12 22-MAY-1 2 22-MAY-1 2 22-MAY-1 2 22-MAY-1 2 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-1 2 22-MAY-1 2 22-MAY-1 2 22-MAY-1 2 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 22-MAY-12 14-NOV-12 Sample Nuclide Description CHANNEL CATFISH K-40 CHANNEL CATFISH MN-54 CHANNEL CATFISH CO-58 CHANNEL CATFISH FE-59 CHANNEL CATFISH CO-60 CHANNEL CATFISH ZN-65 CHANNEL CATFISH 1-131 CHANNEL CATFISH CS-134 CHANNEL CATFISH CS-1 37 CHANNEL CATFISH H-3 COMMON CARP K-40 COMMON CARP MN-54 COMMON CARP CO-58 COMMON CARP FE-59 COMMON CARP CO-60 COMMON CARP ZN-65 COMMON CARP 1-131 COMMON CARP CS-1 34 COMMON CARP CS-1 37 COMMON CARP H-3 FRESHWATER DRUM K-40 FRESHWATER DRUM MN-54 FRESHWATER DRUM CO-58 FRESHWATER DRUM FE-59 FRESHWATER DRUM CO-60 FRESHWATER DRUM ZN-65 FRESHWATER DRUM 1-131 FRESHWATER DRUM CS-134 FRESHWATER DRUM CS-137 FRESHWATER DRUM H-3 SMALLMOUTH BUFFALO K-40 SMALLMOUTH BUFFALO MN-54 SMALLMOUTH BUFFALO CO-58 SMALLMOUTH BUFFALO FE-59 SMALLMOUTH BUFFALO CO-60 SMALLMOUTH BUFFALO ZN-65 SMALLMOUTH BUFFALO 1-131 SMALLMOUTH BUFFALO CS-134 SMALLMOUTH BUFFALO CS-137 SMALLMOUTH BUFFALO H-3 BIGMOUTH BUFFALO K-40 Gamma Spectrum & H-3 Concentration (pCi/Kg Wet)

Duplicate Analysis 3,497.2 +/-

3,289.8 +/-

3,247.8 +/-

3,135.4 +/-

2,968.7 +/-

360.0 14.1 12.9 21.0 9.6 16.3 17.0 9.5 10.7 114.0 391.4 13.4 11.3 12.4 8.9 32.8 24.0 12.2 8.2 118.0 348.8 12.7 8.6 21.7 12.2 34.0 13.6 8.8 15.6 117.0 361.7 11.4 7.5 20.3 11.1 10.3 15.1 10.9 14.0 114.0 345.8 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 60

Exposure Pathway - Ingestion Fish Location JRR Collection Date 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 Sample Nuclide Description BIGMOUTH BUFFALO MN-54 BIGMOUTH BUFFALO CO-58 BIGMOUTH BUFFALO FE-59 BIGMOUTH BUFFALO CO-60 BIGMOUTH BUFFALO ZN-65 BIGMOUTH BUFFALO 1-131 BIGMOUTH BUFFALO CS-1 34 BIGMOUTH BUFFALO CS-137 BIGMOUTH BUFFALO H-3 COMMON CARP K-40 COMMON CARP MN-54 COMMON CARP CO-58 COMMON CARP FE-59 COMMON CARP CO-60 COMMON CARP ZN-65 COMMON CARP 1-131 COMMON CARP CS-1 34 COMMON CARP CS-1 37 COMMON CARP H-3 SMALLMOUTH BUFFALO K-40 SMALLMOUTH BUFFALO MN-54 SMALLMOUTH BUFFALO CO-58 SMALLMOUTH BUFFALO FE-59 SMALLMOUTH BUFFALO CO-60 SMALLMOUTH BUFFALO ZN-65 SMALLMOUTH BUFFALO 1-131 SMALLMOUTH BUFFALO CS-134 SMALLMOUTH BUFFALO CS-137 SMALLMOUTH BUFFALO H-3 WHITE CRAPPIE K-40 WHITE CRAPPIE K-40 WHITE CRAPPIE MN-54 WHITE CRAPPIE MN-54 WHITE CRAPPIE CO-58 WHITE CRAPPIE CO-58 WHITE CRAPPIE FE-59 WHITE CRAPPIE FE-59 WHITE CRAPPIE CO-60 WHITE CRAPPIE CO-60 WHITE CRAPPIE ZN-65 WHITE CRAPPIE ZN-65 Gamma Spectrum & H-3 Concentration (pCi/Kg Wet)

Duplicate Analysis 2,944.1 +/-

3,129.2 +/-

3,173.6 +/-

3,111.5 +/-

11.0 9.7 21.7 10.7 13.5 46.3 9.8 12.2 110.0 362.3 10.5 15.0 17.4 15.5 9.2 33.8 10.8 11.2 119.0 383.6 9.4 9.3 27.0 8.9 25.0 35.4 9.0 12.9 120.0 355.7 376.8 11.9 16.5 12.5 9.2 31.0 29.7 10.7 6.5 23.6 19.2 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 61

Exposure Pathway - Ingestion Fish Location JRR Collection Date 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 14-NOV-12 Sample Description WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE WHITE CRAPPIE Nuclide 1-131 1-131 CS-134 CS-134 CS-137 CS-1 37 H-3 H-3 Gamma Spectrum & H-3 Concentration (pCi/Kg Wet) 29.1 34.5 11.0 12.7 11.2 14.2 118.0 118.0 Duplicate Analysis Duplicate Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-62

Exposure Pathway - Ingestion Food/Garden Location B-1 Collection Date 26-MAR-1 2 26-MAR-1 2 26-MAR-1 2 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-1 2 26-MAR-1 2 26-MAR-1 2 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-1 2 16-APR-12 16-APR-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 27-AUG-12 27-AUG-12 27-AUG-12 27-AUG-12 27-AUG-12 27-AUG-1 2 27-AUG-1 2 27-AUG-1 2 Sample Description Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Analysis HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 4,920.5 352.2 7,798.0 563.8 9,300.1 774.8 6,914.2 139.5

+/-

405.5 9.8 8.0 30.1 10.9 25.9 7.1 14.6 8.4 13.1

+/I-193.4

+/i-569.7 13.2 12.3 38.9 21.3 40.3 14.2 31.1 18.1 20.9

+/I-210.7

+/I-657.9 17.1 21.7 30.2 12.5 43.0 23.0 24.2 11.6 19.1

+-/-

180.6

+/I-519.4 15.6 21.2 33.6 12.6 32.4 19.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 63

Exposure Pathway - Ingestion Food/Garden Location B-I Collection Date 27-AUG-12 27-AUG-12 27-AUG-1 2 24-SEP-1 2 24-SEP-1 2 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-1 2 15-OCT-12 15-OCT-1 2 15-OCT-12 15-OCT-12 15-OCT-12 15-OCT-12 15-OCT-12 15-OCT-1 2 15-OCT-12 15-OCT-12 15-OCT-1 2 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 Sample Description HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Analysis LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 501.7 5,347.8 598.2 5,610.8 695.7 6,076.0

+1-

+1-

+1-

+1-

+1-

+1-32.1 14.0 15.9 133.2 405.8 13.2 9.4 24.1 7.8 22.1 11.2 30.6 9.8 12.3 186.6 478.3 16.0 14.6 23.5 15.1 31.9 19.0 30.7 13.6 11.6 160.5 421.4 14.8 7.8 29.2 10.5 21.2 13.6 20.5 12.4 9.0 HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-64

Exposure Pathway - Ingestion FoodlGarden Location D-2 Collection Date 26-MAR-12 26-MAR-1 2 26-MAR-1 2 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-12 26-MAR-1 2 26-MAR-1 2 16-APR-12 16-APR-12 16-APR-1 2 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-1 2 29-MAY-1 2 29-MAY-1 2 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 Sample Description Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Analysis RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB HORSERADISH LEAVES HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 262.1 +/-

3,033.2 +/-

347.8+-

5,707.9+1 508.0+-

5,891.9+-

580.9+-

5,110.9+1 133.3 374.3 15.0 15.8 23.3 11.6 39.6 17.4 24.7 14.9 10.7 163.5 417.7 6.8 9.5 29.3 11.3 23.8 15.9 22.6 12.7 13.0 152.2 442.1 14.0 14.0 19.8 13.0 42.4 19.8 28.9 14.3 14.9 241.9 51.0 9.7 19.5 41.7 15.5 36.1 14.3 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-65

Exposure Pathway - Ingestion Food/Garden Location D-2 Collection Date 25-JUN-12 25-JUN-12 25-JUN-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 27-AUG-12 27-AUG-1 2 27-AUG-1 2 27-AUG-12 27-AUG-12 27-AUG-12 27-AUG-12 27-AUG-12 27-AUG-12 27-AUG-12 27-AUG-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 15-OCT-12 15-OCT-12 15-OCT-12 15-OCT-1 2 15-OCT-1 2 Sample Description Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Analysis HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB RHUBARB HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH HORSERADISH KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES LEAVES 1-131 CS-134 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 680.9 4,342.7 763.6+/

5,605.9 +/-

5,632.8+-

5,292.7+-

+1-

+1-36.1 15.6 18.9 217.5 493.8 12.9 12.0 28.2 14.9 29.2 21.7 37.2 17.1 18.6 160.2 431.6 14.0 12.5 18.0 11.9 18.9 12.3 18.4 13.9 10.8 112.3 404.7 10.6 7.6 25.9 6.5 13.0 14.0 27.7 12.9 13.2 161.2 421.4 16.7 11.3 21.5 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-66

Exposure Pathway - Ingestion Food/Garden Location D-2 Collection Date 15-OCT-1 2 15-OCT-1 2 15-OCT-1 2 15-OCT-1 2 15-OCT-1 2 15-OCT-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 Sample Description Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Analysis KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE KALE CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 4,290.3+-

16.8 21.2 12.4 34.1 13.6 16.7 144.2 381.8 9.8 8.8 22.1 7.9 28.0 10.3 17.4 9.1 14.3 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-67

Exposure Pathway - Ingestion Food/Garden Location H-2 Collection Date 27-AUG-12 27-AUG-12 27-AUG-1 2 27-AUG-12 27-AUG-12 27-AUG-1 2 27-AUG-1 2 27-AUG-1 2 27-AUG-1 2 27-AUG-1 2 27-AUG-1 2 24-SEP-12 24-SEP-1 2 24-SEP-12 24-SEP-1 2 24-SEP-1 2 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 15-OCT-12 15-OCT-12 15-OCT-12 15-OCT-12 15-OCT-12 15-OCT-12 15-OCT-1 2 15-OCT-12 Sample Description Nuclide Gamma Spectrum Concentration (pCilKg Wet)

Duplicate Analysis HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 BE-7 K-40 K-40 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 1-131 1-131 CS-134 CS-134 CS-137 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 500.3 5,820.5 526.7 504.2 6,913.7 6,823.9 535.8 5,549.0

+1-

+1-

+1-

+1-

+1-

+1-

+1-

+1-150.8 478.8 8.6 10.0 33.3 6.9 30.3 15.6 26.7 10.0 13.8 155.6 155.0 431.2 485.2 11.6 12.9 14.3 6.9 21.8 21.8 8.3 7.5 31.0 18.2 12.4 10.2 26.4 19.1 8.8 7.1 11.6 7.3 197.4 436.8 12.0 14.2 25.8 10.4 18.6 13.9 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-68

Exposure Pathway - Ingestion Food/Garden Location H-2 Collection Date 15-OCT-12 15-OCT-12 15-OCT-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 Sample Description HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES Nuclide 1-131 CS-1 34 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 Gamma Spectrum Concentration (pCi/Kg Wet) 32.9 16.1 Duplicate Analysis 921.5 5,862.3 12.8

+/-

183.0

+/-

439.0 11.6 10.8 26.3 13.6 31.3 14.2 35.9 13.1 10.7 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-69

Exposure Pathway - Ingestion FoodlGarden Location N-1 Collection Date 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 16-APR-12 29-MAY-1 2 29-MAY-1 2 29-MAY-1 2 29-MAY-1 2 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 Sample Description HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES Nuclide BE-7 BE-7 K-40 K-40 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 1-131 1-131 CS-134 CS-134 CS-137 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 Gamma Spectrum Concentration (pCi/Kg Wet) 270.2 3,418.6 4,372.1 490.2 3,868.2 808.3 6,238.8 265.5

+/-

139.0

+/-

466.3

+/-

449.0 15.4 13.1 16.0 7.9 32.3 26.8 15.8 17.8 26.2 34.9 11.5 18.0 40.2 21.8 16.9 14.4 21.2 18.2

+/-

165.4

+/-

452.7 16.7 20.7 26.8 17.0 36.0 12.4 25.4 13.8 13.9

+/-

192.4

+/-

504.7 10.9 15.2 20.0 14.2 37.9 21.1 Duplicate Analysis Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-70

Exposure Pathway - Ingestion Food/Garden Location N-1 Collection Date 25-JUN-12 25-JUN-12 25-JUN-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 Sample Description Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Analysis HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES CANTALOUPE LEAVES CANTALOUPE LEAVES CANTALOUPE LEAVES CANTALOUPE LEAVES CANTALOUPE LEAVES CANTALOUPE LEAVES CANTALOUPE LEAVES CANTALOUPE LEAVES CANTALOUPE LEAVES CANTALOUPE LEAVES CANTALOUPE LEAVES 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 1,251.5 5,859.8

+1-

+1-38.2 14.2 14.1 269.3 616.2 15.4 15.6 40.2 19.3 21.2 19.4 40.2 17.5 18.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 71

Exposure Pathway - Ingestion Food/Garden Location Q-6 Collection Date 29-MAY-12 29-MAY-1 2 29-MAY-1 2 29-MAY-1 2 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 25-JUN-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 30-JUL-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 24-SEP-12 Sample Description Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Analysis CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CORN LEAVES CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 914.2 6,538.0 3,347.8 6,701.3 2,163.1 6,996.9 212.4 5,149.1

+/I-183.2

+/I-507.5 18.7 16.3 33.6 12.2 24.2 16.1 30.3 15.9 18.6

+/I-223.6

+/I-443.8 15.4 10.4 18.3 11.3 30.5 12.1 23.8 13.2 15.1

+/I-352.9

+/i-734.2 26.9 18.3 47.6 13.0 42.7 24.8 49.7 27.8 32.1

+/I-81.5

+/I-319.8 8.1 10.4 26.2 9.8 20.2 11.2 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 72

Exposure Pathway - Ingestion Food/Garden Location Q-6 Collection Date 24-SEP-12 24-SEP-12 24-SEP-12 15-OCT-1 2 15-OCT-12 15-OCT-12 15-OCT-12 15-OCT-1 2 15-OCT-1 2 15-OCT-1 2 15-OCT-12 15-OCT-12 15-OCT-12 15-OCT-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-1 2 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 12-NOV-12 Sample Description Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Analysis CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE CABBAGE 1-131 CS-1 34 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 717.0 4,058.9 286.1 4,833.5 20.0 10.1 8.0

+/-

181.1

+/-

358.8 12.1 14.4 24.5 12.5 21.3 14.6 26.8 11.0 10.0

+1-134.4

+/-

460.6 8.5 10.8 27.1 17.5 21.9 11.1 15.9 11.8 11.4 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-73

Exposure Pathway - Ingestion Feed and Forage Location NR-D1 Collection Date 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 Sample Description IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS Nuclide BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 Gamma Spectrum Concentration (pCi/Kg Wet) 77.

14,309.0 +/-

346.

Duplicate Analysis 9

4 9.2 7.2 28.9 11.9 22.0 6.0 22.8 7.0 8.6 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-74

Exposure Pathway - Ingestion Feed and Forage Location NR-D2 Collection Date 29-AUG-12 29-AUG-1 2 29-AUG-1 2 29-AUG-12 29-AUG-12 29-AUG-12 29-AUG-12 29-AUG-1 2 29-AUG-12 29-AUG-12 29-AUG-12 Sample Desctiption Nuclide IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 Gamma Spectrum Concentration (pCi/Kg Wet) 34.1 3,033.4 +/-

252.6 5.9 6.1 6.9 4.3 5.0 3.5 8.0 8.1 8.7 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-75

Exposure Pathway - Ingestion Feed and Forage Location NR-UI Collection Date 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 Sample Description Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Analysis IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN IRRIGATED CORN BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 80.8 2,993.5 +/-

270.7 4.9 5.2 7.7 4.0 4.4 4.6 8.1 7.0 6.9 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-76

Exposure Pathway - Aquatic Bottom Sediment Location DC Collection Date 02-MAY-12 02-MAY-12 02-MAY-1 2 02-MAY-1 2 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-1 2 02-MAY-1 2 29-NOV-12 29-NOV-12 29-NOV-12 29-NOV-12 29-NOV-12 29-NOV-1 2 29-NOV-12 29-NOV-12 29-NOV-12 Nuclide Gamma Spectrum Concentration (pCi/Kg Dry)

Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-137 FE-55 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-137 FE-55 10,035.0 66.6 i1,192.0

+/-

1,063.0 43.6 43.1 134.8 30.6 96.0 43.7

+/-

39.0

< 15,738.0

+/-

1,056.0 46.7 42.5 26.6 42.6 61.1 38.6

+/-

55.6 14,788.6 111.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-77

Exposure Pathway - Aquatic Bottom Sediment Location EEA Collection Date 11-APR-12 11-APR-12 11-APR-12 11-APR-12 11-APR-12 11-APR-12 11-APR-12 11-APR-12 Nuclide Gamma Spectrum Concentration (pCi/Kg Dry)

Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 11,179.0 +/-

566.5 18.5 18.6 31.3 12.6 29.7 12.2

+/-

15.0 49.8 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-78

Exposure Pathway - Aquatic Bottom Sediment Location ESW 2012-3 Collection Date 02-MAY-1 2 02-MAY-1 2 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-1 37 FE-55 Gamma Spectrum Concentration (pCi/Kg Dry) 9,556.1 +/-

1,024.0 29.3 52.2 155.8 51.1 113.0 31.7 54.7

< 16,760.0 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-79

Exposure Pathway - Aquatic Bottom Sediment Location ESW 2012-4 Collection Date 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 FE-55 Gamma Spectrum Concentration (pCiIKg Dry) 7,881.1 +/-

600.4 31.5 40.5 42.2 20.7 53.1 26.0 49.1 +/-

28.7 14,854.4 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-80

Exposure Pathway - Aquatic Bottom Sediment Location JRR Collection Date 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-1 2 02-MAY-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-12 19-NOV-1 2 19-NOV-12 19-NOV-12 19-NOV-1 2 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-137 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 Gamma Spectrum Concentration (pCi/Kg Dry) 11,955.0 +/- 1,125.0 52.7 54.8 76.1 18.0 79.8 41.4 121.8 +/-

54.9 9,398.0 +/-

590.9 22.6 21.7 76.8 10.8 47.9 18.4 45.4 +/-

23.9 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 81

Exposure Pathway - Aquatic Bottom Sediment Location MUDS Collection Date 05-SEP-12 05-SEP-12 05-SEP-12 05-SEP-12 05-SEP-12 05-SEP-1 2 05-SEP-12 05-SEP-12 Nuclide Gamma Spectrum Concentration (pCi/Kg Dry)

Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 7,502.3 +/-

470.1 15.2 14.8 15.8 14.5 36.0 14.2

+/-

15.3 26.4 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 82

Exposure Pathway - Aquatic Bottom Sediment Location SC Collection Date 15-JUN-12 15-JUN-12 15-JUN-12 15-JUN-12 15-JUN-12 15-JUN-12 15-JUN-12 15-JUN-12 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 Gamma Spectrum Concentration (pCi/Kg Dry) 10,824.0 +/-

653.6 33.7 25.5 47.2 15.2 40.3 15.7 25.0 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 83

Exposure Pathway - Aquatic Bottom Sediment Location UHS 2012-10 Collection Date 02-MAY-1 2 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 Nuclide Gamma Spectrum Concentration (pCi/Kg Dry)

Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 FE-55 10,751.0

+/-

1,126.0 50.1 49.9 82.2 10.9 50.6 41.0

+/-

55.8 17,144.0 99.2 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-84

Exposure Pathway - Aquatic Bottom Sediment Location UHS 2012-11 Collection Date 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-1 2 02-MAY-1 2 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 FE-55 Gamma Spectrum Concentration (pCi/Kg Dry) 11,301.0 +/-

944.3 43.4 54.1 144.5 19.1 81.4 36.7 47.7 17,177.0 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-85

Exposure Pathway - Aquatic Bottom Sediment Location UHS 2012-12 Collection Nuclide Date Gamma Spectrum Concentration (pCi/Kg Dry)

Duplicate Analysis 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-1 2 02-MAY-1 2 02-MAY-1 2 02-MAY-12 02-MAY-12 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 FE-55 11,131.0 +/-

899.3 46.5 43.3 118.5 27.6 87.8 36.6 38.3 16,736.0 91.0 +/-

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-86

Exposure Pathway - Aquatic Bottom Sediment Location UHS 2012-13 Collection Date 08-NOV-1 2 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-1 2 08-NOV-12 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 FE-55 Gamma Spectrum Concentration (pCi/Kg Dry) 8,028.3 +/-

920.1 53.6 33.6 129.0 39.1 84.7 34.0 44.4 14,708.8 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-87

Exposure Pathway - Aquatic Bottom Sediment Location UHS 2012-14 Collection Date 08-NOV-1 2 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 Nuclide Gamma Spectrum Concentration (pCilKg Dry)

Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 FE-55 9,542.0 +/-

926.4 46.1 35.6 71.6 36.6 69.7 37.6 41.2 14,708.8 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 88

Exposure Pathway - Aquatic Bottom Sediment Location UHS 2012-15 Collection Date 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-1 2 08-NOV-1 2 08-NOV-12 Nuclide Gamma Spectrum Concentration (pCi/Kg Dry)

Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 FE-55 9,676.4 +/-

826.3 38.3 50.4 109.5 37.6 66.6 36.3 44.9 15,003.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-89

Exposure Pathway - Aquatic Bottom Sediment Location UHS 2012-17 Collection Date 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-1 2 08-NOV-1 2 08-NOV-1 2 08-NOV-1 2 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 FE-55 Gamma Spectrum Concentration (pCi/Kg Dry) 9,296.6 +/-

919.7 37.6 49.7 91.5 37.6 71.5 38.7 53.7

< 15,003.0 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-90

Exposure Pathway - Aquatic Bottom Sediment Location UHS 2012-9 Collection Date 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-137 FE-55 Gamma Spectrum Concentration (pCi/Kg Dry) 8,403.1 +/-

845.5 36.9 49.2 90.5 21.7 72.0 28.4 39.6 16,396.0 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 91

Exposure Pathway - Aquatic Bottom Sediment Location UHS HS-3 Collection Date 02-MAY-1 2 02-MAY-1 2 02-MAY-1 2 02-MAY-1 2 02-MAY-1 2 02-MAY-1 2 02-MAY-1 2 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 02-MAY-12 Nuclide Gamma Spectrum Concentration (pCiIKg Dry)

K-40 K-40 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 CS-134 CS-1 34 CS-1 37 CS-1 37 FE-55 FE-55 11,127.0 +/-

10,149.0 +/-

72.9+1 i25.8+1 898.0 973.3 42.7 46.2 52.6 34.2 78.4 125.9 34.0 25.0 86.0 64.7 30.8 37.7 36.2 68.0 16,752.0 16,621.0 Duplicate Analysis Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-92

Exposure Pathway - Aquatic Bottom Sediment Location UHS HS-4 Collection Date 08-NOV-1 2 08-NOV-1 2 08-NOV-1 2 08-NOV-1 2 08-NOV-1 2 08-NOV-12 08-NOV-12 08-NOV-12 08-NOV-12 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-137 FE-55 Gamma Spectrum Concentration (pCi/Kg Dry) 9,566.8 +/-

1,050.0 32.7 35.1 77.0 21.4 84.5 31.5 67.5 +/-

33.2

< 15,003.0 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 93

Exposure Pathway - Aquatic Vegetation Location DC-ALT Collection Date Sample Description Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Sample 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 15-AUG-12 AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 1,196.2 4 2,653.4 4

  • -/-

173.8

  • -/-

287.5 9.4 13.2 19.8 10.7 20.0 9.5 19.8 12.2 11.7 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-94

Exposure Pathway - Aquatic Vegetation Location EEA Collection Date 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 Sample Description SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH SPIKERUSH Nuclide BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-137 Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Sample 454.7 4,600.8

+/-

76.7

+/-

225.6 10.6 8.2

.21.9 7.1 20.6 10.4 27.3 9.3 11.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

95

Exposure Pathway - Aquatic Vegetation Location MUDS Collection Date 05-SEP-12 05-SEP-12 05-SEP-1 2 05-SEP-12 05-SEP-12 05-SEP-12 05-SEP-12 05-SEP-12 05-SEP-12 05-SEP-12 05-SEP-12 Sample Description AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED Nuclide BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Sample 314.4 1,925.1

+/-

161.8

+/-

262.8 11.2 7.6 25.3 9.6 18.9 11.9 32.8 9.9 12.9 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -

96

Exposure Pathway - Aquatic Vegetation Location SC Collection Date Sample Description Nuclide Gamma Spectrum Concentration (pCi/Kg Wet)

Duplicate Sample 29-MAY-1 2 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-1 2 29-MAY-1 2 29-MAY-1 2 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-1 2 29-MAY-1 2 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 29-MAY-12 CATTAILS CATTAILS CATTAI LS CATTAI LS CATTAI LS CATTAI LS CATTAILS CATTAILS CATTAILS CATTAI LS CATTAI LS CATTAI LS CATTAI LS CATTAI LS CATTAI LS CATTAILS CATTAILS CATTAI LS CATTAI LS CATTAI LS CATTAI LS CATTAI LS BE-7 BE-7 K-40 K-40 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 1-131 1-131 CS-134 CS-134 CS-137 CS-137 2,220.4 2,127.2

+1-

+1-162.8 Duplicate 139.1 335.0 Duplicate 297.4 11.6 Duplicate 12.9 6.7 Duplicate 10.3 22.9 Duplicate 16.4 9.4 Duplicate 9.4 22.0 Duplicate 16.2 16.5 Duplicate 11.1 28.1 Duplicate 14.6 11.6 Duplicate 12.4 12.9 Duplicate 14.2 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-97

Exposure Pathway - Terrestrial Vegetation Location EEA Collection Date 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 12-JUN-12 Sample Description PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE Nuclide BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 Gamma Spectrum Concentration (pCi/Kg Wet) 1,084.4+/-

181.1 13,379.0 +/-

532.9 15.4 16.9 36.4 17.5 32.8 14.3 44.4 16.0 17.6 Duplicate Analysis 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-98

Exposure Pathway - Terrestrial Soil Location EEA Collection Date 13-MAR-12 13-MAR-12 13-MAR-1 2 13-MAR-1 2 13-MAR-12 13-MAR-12 13-MAR-12 13-MAR-12 Nuclide Gamma Spectrum Concentration (pCilKg Dry)

Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-137 8,520.0 +/-

628.2 28.3 26.0 38.9 14.9 44.5 19.0 44.9 155.2 +/-

2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-99

Exposure Pathway - Ingestion Meat Location A1.5 Collection Date Sample Description Nuclide Gamma Spectrum & H-3 Concentration (pCi/Kg Wet)

Duplicate Analysis 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 17-SEP-12 DEER DEER DEER DEER DEER DEER DEER DEER DEER K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-1 37 H-3 2,639.5+/-

916.0 +/-

258.2 10.4 8.0 20.1 8.8 12.9 8.3 12.8 93.0 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-100

WOLF CREEK GENERATING STATION 2012 LAND USE CENSUS REPORT Revision 1 Ad F

Prepared by:

Peer Review:

Approved by:

Teresa L. Rice Dan E. Haines Robert A. Hammond 04/09/2013 Date 04/09/2013 Date 04/09/2013 Date 2012 Land Use Census Report, Revision 1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 1

EXECUTIVE

SUMMARY

The 2012 Land Use Census Report has been revised to incorporate information received since the initial report was completed in October 2012.

The annual Land Use Census of rural residents within five miles of the Wolf Creek Generating Station (WCGS) has been completed in 2012 in accordance with AP 07B-004, [Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program)].

No program changes are necessary regarding milk locations. Again, no milk sampling locations were identified.

The two broadleaf vegetation locations with the highest calculated annual average D/Q rankings are A2.60-17TE1520 and Q2.35-MILA1619.

AP 07B-004 specifies, "Alternate sampling locations may be used to provide continued monitoring". The third-ranked garden is N2.38-RODR9.

The landowners of these gardens have agreed to participate in the 2013 sample program.

BACKGROUND Section 5.2, Attachment A, of the ODCM procedure (AP 07B-004), directs that "a Land Use Census shall be conducted annually during the growing season to identify the nearest (1) milk animal, (2) residence, and (3) garden of greater than 500 square feet producing broadleaf vegetation in each of the 16 meteorological sections within five miles of the WCGS site" and "the results of the Land Use Census shall be included in the Annual Radiological Environmental Operating Report."

Table 5-1, Attachment A, of the ODCM (AP 07B-004) requires that broadleaf vegetation samples be collected from "two indicator locations (using the criteria from the "Land Use Census" section) with highest calculated annual average D/Q."

Table 5-1, Attachment A, of the ODCM (AP 07B-004) also requires that milk samples be collected from "three indicator locations within 5 miles of the site having the highest dose potential."

METHODOLOGY Over two hundred surveys were mailed to the rural residents living within five miles of WCGS.

A follow-up survey was sent to residents who did not respond.

The survey excluded the residents of New Strawn, Burlington, and a trailer park north of Burlington. These locations were excluded due to the large number of households and the low likelihood that information gained from these residences would affect the locations chosen for REMP sampling. Drive-by information was collected for the nearest residences that did not return surveys.

The information collected was compiled and the results are identified in Tables 1-3.

Calculations were performed so that garden locations could be ranked by their respective D/Q.

These results are contained in Table 4.

2012 Land Use Census Report, Revision 1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 2

RESULTS NOTE: A Global Positioning System was used to verify residence distances and sectors.

One change was noted for the nearest occupied residences in each sector. That change occurred in sector R.

Ten changes were noted for the nearest garden producing broadleaf vegetation.

These changes are identified in Table 3.

There were no changes regarding milk sample locations. Again, no locations were identified that routinely milked animals for human consumption.

2012 Land Use Census Report, Revision 1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 3

TABLE I 2012 Land Use Census Data Location of Nearest:

Sector A

B C

D E

F G

H J

K L

M N

P Q

R Residence A2.60-17TE1 520 B3.53-QURD1755 C1.92-16RD1655 D2.03-QULA1571 E1.78-QULA1451 F1.84-QULA1419 G3.03-13RD1820 H3.09-12RD1711 J3.70-1 1 RD1 540 K2.70-12LA1439 L2.10-NARD 1339 M2.34-14RD1330 N2.08-15RD1350 P2.76-HW751534 Q2.35-MILA1619 R2.08-NALN1650 Milking Animals None None None None None None None None None None None None None None None None Broadleaf Garden A2.60-17TE1520 None C3.38-17RD1755 D2.33-RERD1520 None F2.44-RERD1391 None H4.87-10RD1670 J3.84-11 RD1499 K4. 1 0-NARD1 120 L2.39-NARD1309 M4.42-LYRD1231 N2.38-RODR9 P3.17-WDST425 Q2.35-MILA1619 None Identifiers are based upon the following protocol:

EXAMPLE: A2.60-17TE1520 "A" = Sector A "2.60" = 2.60 miles from the reactor "1 7TE1520" = address 2012 Land Use Census Report, Revision 1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D-4

TABLE 2 SECTOR 2011 NEAREST 2012 NEAREST RESIDENCE RESIDENCE A

A2.60-17TE1 520 A2.60-17TE1520 B

B3.53-QURD1755 B3.53-QURD1755 C

C1.92-16RD1655 Cl.92-16RD1655 D

D2.03-QULA1571 D2.03-QULA1571 E

E1.78-QULA1451 E1.78-QULA1451 F

F1.84-QULA1419 F1.84-QULA1419 G

G3.03-13RD1820 G3.03-13RD1820 H

H3.09-12RD1711 H3.09-12RD1711 J

J3.70-11RD1540 J3.70-11RD1540 K

K2.70-12LA1439 K2.70-12LA1439 L

L2.10-NARD1339 L2.10-NARD1339 M

M2.34-14RD1330 M2.34-14RD1330 N

N2.08-15RD1350 N2.08-15RD1350 P

P2.76-HW751534 P2.76-HW751534 Q

Q2.35-MILA1619 Q2.35-MILA1619 R

R4.43-NARD1891 R2.08-NALN1650 NOTE: Entries underlined indicate changes from the 2011 Land Use Census.

2012 Land Use Census Report, Revision 1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 5

TABLE 3 2012 Land Use Census Milk and Garden Data SECTOR 2011 2012 2011 NEAREST 2012 NEAREST MILKING MILKING GARDEN GARDEN ANIMALS ANIMALS PRODUCING PRODUCING BROADLEAF BROADLEAF VEGETATION VEGETATION A

None None A4.91-OXRD1940 A2.60-17TE1520 B

None None None None C

None None C4.63-RERD1825 C3.38-17RD1755 D

None None D2.41-RERD1541 D2.33-RERD1520 E

None None None None F

None None F2.39-14RD1802 F2.44-RERD1391 G

None None G3.77-12RD1831 None H

None None H3.30-QURD1175 H4.87-10RD1670 J

None None J4.00-PLRD1080 J3.84-11RD1499 K

None None K4.10-NARD1120 K4.10-NARD1120 L

None None None L2.39-NARD1309 M

None None M3.10-13LA1290 M4.42-LYRD1231 N

None None N2.38-RODR9 N2.38-RODR9 P

None None P2.76-HW751534 P3.17-WDST425 Q

None None Q2.35-MILA1619 Q2.35-MILA1619 R

None None None None NOTE: Underlined entries indicate changes from the 2011 Land Use Census.

2012 Land Use Census Report, Revision 1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 6

TABLE 4 Information Used for D/Q Calculations FROM LAND FROM USE CENSUS SA-10-004 Eval.

DIST CALC NEAR NEAR FAR FAR SECTOR SECTOR (MI)

(METERS)

DIST D / Q DIST D / Q CALC RANKING A

2.60 4184 4000 1.76E-09 5000 1.19E-09 1.66E-09 1

B C

3.38 5440 5000 3.03E-10 6000 2.23E-10 2.68E-10 11 D

2.33 3750 3000 4.46E-10 4000 2.67E-10 3.12E-10 10 EI F

2.44 3927 3000 7.22E-10 4000 4.33E-10 4.54E-10 6

G H

4.87 7838 7000 3.83E-10 8000 3.09E-10 3.21E-10 9

J 3.84 6180 6000 4.33E-10 7000 3.22E-10 4.13E-10 7

K 4.10 6598 6000 3.82E-10 7000 2.84E-10 3.23E-10 8

L 2.39 3846 3000 1.04E-09 4000 6.24E-10 6.88E-10 4

M 4.42 7113 7000 2.13E-10 8000 1.72E-10 2.08E-10 12 N

2.38 3830 3000 1.25E-09 4000 7.51E-10 8.36E-10 3

P 3.17 5102 5000 4.68E-10 6000 3.44E-10 4.55E-10 5

Q 2.35 3782 3000 1.53E-09 4000 9.17E-10 1.05E-09 2

R

_ 1 1

1 Originated by:

Verified by:

Date:

4/09/13 Date:

4/09/13 2012 Land Use Census Report, Revision 1 2012 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 7