W9LF CREEK NUCLEAR OPERATING CORPORATION Michael J. Westman Manager Regulatory Affairs April 23, 2014 RA 14-0048 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
Subject:
Docket No. 50-482: 2013 Annual Radiological Environmental Operating Report Gentlemen:
The purpose of this letter is to submit the enclosed Annual Radiological Environmental Operating Report, which is being submitted pursuant to Wolf Creek Generating Station (WCGS) Technical Specification 5.6.2.
This report covers radiological environmental monitoring around WCGS for the period of January 1, 2013, through December 31, 2013.
This letter contains no commitments. If you have any questions concerning this matter, please contact me at (620) 364-4009, or Mr. William Muilenburg, at (620) 364-4186.
Sincerely, Michael J. Westman MJW/rlt
Enclosure:
2013 Annual Radiological Environmental Operating Report cc:
M. L. Dapas (NRC), w/e C. F. Lyon (NRC), w/e N. F. O'Keefe (NRC), w/e Senior Resident Inspector (NRC), w/e P.O. Box 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer MIFIHCNET 44-
/
Enclosure to RA 14-0048 Wolf Creek Nuclear Operating Corporation Wolf Creek Generating Station 2013 Annual Radiological Environmental Operating Report (169 pages)
WOLF CREEK NUCLEAR OPERATING CORPORATION WOLF CREEK GENERATING STATION 2013 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT
'F April 15, 2014
TABLE OF CONTENTS List of Tables ii List of Figures ii List of Charts ii Executive Summary 1
Introduction 1
I.
Program Description 1
I1. Discussion of Results 4
Ill. Program Revisions/Changes 9
IV. Program Deviations 10 V. Interlaboratory Comparison Program 10 VI. Comparison to the Radioactive Effluent Release Program 11 Tables 12 Figures 21 Charts 26 Appendix A - Interlaboratory Comparison Program Results A-1 Appendix B - Summary Tables B-1 Appendix C - Individual Sample Results C-1 Air Particulate and Charcoal Filters C-1 Quarterly Air Particulate - Gamma C-13 Surface Water C-25 Ground Water C-33 Drinking Water C-49 Quarterly Drinking Water - Tritium C-57 Shoreline Sediment C-59 Fish C-62 Food/Garden C-67 Feed and Forage C-74 Bottom Sediment C-77 Aquatic Vegetation C-93 Terrestrial Vegetation C-96 Soil C-98 Deer C-100 Appendix D - Land Use Census Report D-1
LIST OF TABLES 1 Radiological Environmental Monitoring Program Description 12 2 Sample Location Identifiers, Distances (Miles) and Directions (Sectors) 17 3
OSL Dosimeter Results 20 LIST OF FIGURES 1 Airborne Pathway Sampling Locations 21 2
Direct Radiation Pathway Sampling Locations 22 3 Waterborne Pathway Sampling Locations 23 4
Ingestion Pathway Sampling Locations 24 5
Distant Sampling Locations 25 LIST OF CHARTS 1 Airborne Gross Beta Weekly Results 26 2
Historical Airborne Smoothed Indicator and Control Gross Beta 27 3
OSL Dosimeters - Indicator and Control Locations 28 4
Historical TLD Nearsite Locations and Control Locations 29 5
Coffey County Lake Surface Water Tritium Data 30 6
Drinking Water Gross Beta (5 years) 31 7 Detected Cs-1 37 Activity in Bottom Sediment 32 ii
EXECUTIVE
SUMMARY
Plant-related activation, corrosion, or fission products were not detected during 2013 in airborne particulate and radioiodine, filters, drinking water, ground water, broadleaf vegetation, shoreline sediment, crops, aquatic vegetation, terrestrial vegetation, bottom sediment, or soil samples.
Activation, corrosion or fission products attributable to plant operation were detected during 2013 in surface water, fish, and deer samples.
Nuclides detected in Radiological Environmental Monitoring Program (REMP) samples were below applicable Nuclear Regulatory Commission (NRC) reporting levels.
Based upon the radiological environmental monitoring program results, it was concluded station operations had no significant radiological impact on the health and safety of the public or the environment.
INTRODUCTION The 2013 Annual Radiological Environmental Operating Report for Wolf Creek Generating Station (WCGS) covers the period from January 1 through December 31, 2013.
WCGS is located in Coffey County, Kansas, approximately five miles northeast of Burlington, Kansas.
Fuel loading commenced at WCGS on March 12, 1985. The operational phase of the REMP began with initial criticality on May 22, 1985, and the first detectable quantities of radioactivity were reported in plant effluents in June 1985.
This report contains a description of the REMP conducted by Wolf Creek Nuclear Operating Corporation (WCNOC), a discussion of monitoring program results, the revisions or changes to the program, program deviations, the Interlaboratory Comparison Program and a comparison to the Radioactive Effluent Release Program. The Interlaboratory Comparison Program results, a summary of results in the NRC Branch Technical Position specified format, the individual sample results, and the Land Use Census Report are included as appendices.
I. PROGRAM DESCRIPTION Radiological environmental monitoring samples were collected according to the schedule in WCGS procedure AP 07B-004, Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program). Radiological environmental monitoring program samples were collected by the WCGS Environmental Management group and were analyzed by Environmental, Inc.
- Landauer, Inc. processed the environmental optically stimulated luminescence (OSL) dosimeters. Table 1 identifies the exposure pathway/sample type, number of samples and sample locations, sample collection frequency, and type and frequency of analysis. Table 2 lists the sample location identifiers, distances and directions from the plant. Samples in addition to those required by AP 07B-004 were also obtained and analyzed.
The following is a description of the sampling and analysis program by individual pathways.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 1 of 32
A. Airborne Pathway Low volume air sampling pumps with digital flow meters continuously collected air particulate and radioiodine samples on 47 mm glass fiber filters and charcoal canisters, respectively. The air particulate filters and charcoal canisters were changed out weekly. Gross beta analysis was performed on the air particulate filters. Air particulate filters were also analyzed quarterly for gamma emitting isotopes. Charcoal canisters were analyzed for 1-131.
Air samples were collected from six locations. The five indicator locations sampled included 2, 18, 32, 37 and 49. A control location near the intersection of 20th Road and Yearling Road (location 53) was also sampled.
Indicator sample locations are shown in Figure 1 and the control sample location is shown in Figure 5.
B: Direct Radiation Pathway Optically stimulated luminescence (OSL) dosimeters were used continuously at 43 locations during the sample year to measure direct radiation. The OSLs were typically positioned roughly 3 to 4 feet above the ground in plastic thermostat boxes. Three OSLs were placed at each designated location. The OSLs were changed out quarterly and analyzed for gamma dose.
Transit dose was measured and subtracted from the ambient dose.
Indicator OSL sample locations are illustrated in Figure 2 and control sample locations are shown in Figure 5. Control sample locations were 39 (Beto Junction) and 53 (near the intersection of 2 0 th Road and Yearling Road).
C. Waterborne Pathway Water samples were analyzed to determine if gamma emitters were present.
In addition to gamma isotopic analysis, radiochemical analysis for 1-131 was performed on drinking water and ground water samples. Gross beta analysis was also performed on drinking water samples.
Tritium analysis was performed monthly by liquid scintillation for surface water and quarterly for drinking water. Tritium analysis was also performed on ground water samples. Four surface water samples from the Coffey County Lake Spillway (SP) location and four surface water samples from the John Redmond Reservoir (JRR) location were also analyzed for Fe-55. The waterborne pathway sample locations are shown in Figures 3 and 5.
Monthly grab samples of surface water were collected from the JRR control location and from the SP indicator location.
The SP indicator sample location is located near the spillway of Coffey County Lake, formerly known as Wolf Creek Lake.
Quarterly grab samples of ground water were collected from seven wells. Six locations (C-10, C-49, F-1, G-2, J-1 and J-2) located hydrologically down gradient from the site were used as indicator sample locations. Location B-12 located hydrologically up gradient from the site was used as a control sample location.
Drinking water was sampled at the water treatment facilities in the towns of Iola (indicator sample location IO-DW) and Burlington (control sample location BW-15).
The Iola facility is located downstream of the site and the Burlington facility is located upstream of the confluence of the Coffey County Lake discharge and the Neosho River. Composite samples were obtained monthly from automatic samplers at each location.
The drinking water automatic samplers collected approximately 27 milliliters of water every two hours.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 2 of 32
Shoreline sediments were sampled semiannually. Gamma isotopic analyses were performed on the shoreline sediment samples.
Shoreline sediment sample locations were the Coffey County Lake discharge cove (DC) indicator location and the JRR control location.
D. Ingestion Pathway Milk was not collected during the sample year. The Land Use Census did not identify any locations producing milk for human consumption within five miles of the plant.
Fish were sampled semiannually from the Coffey County Lake (indicator sample location) and from the tail waters of JRR (control sample location). These sample locations are identified in Figure 4. Gamma isotopic analyses were performed on the boneless edible portions of the fish.
Several species of game fish and rough fish were sampled. Fish were also analyzed for tritium.
Broadleaf vegetation samples were collected monthly when available during the growing season. Three indicator (B-1, H-2 and Q-6) gardens (Figure 4) and one control (D-2) garden (Figure 5) were sampled. Gamma isotopic analyses were performed on these samples.
Crop samples were obtained from two indicator sample locations (NR-D1 and NR-D2) downstream of the confluence of Wolf Creek and the Neosho River. Crops were also sampled from control location NR-U1. Gamma isotopic analysis was performed on each sample. Crop sample locations are identified on Figure 5.
E. Additional Samples Collected (not required by AP 07B-004)
Quarterly, duplicate ground water grab samples were obtained from indicator location C-49 and were labeled L-49. These duplicate samples served as laboratory quality checks. The ground water samples were analyzed for gamma emitters, 1-131, and tritium.
Bottom sediment samples were collected from indicator sample locations at the Coffey County Lake discharge cove (DC), Environmental Education Area (EEA), Make-Up Discharge Structure (MUDS), Ultimate Heat Sink (UHS), Essential Service Water (ESW) channel, and the control sample location (JRR). Gamma isotopic analyses were performed on the bottom sediment samples. Samples obtained from DC, ESW and UHS were also analyzed for Fe-55. Some of the bottom sediment samples were collected as part of a cooperative sampling effort with the Kansas Department of Health and Environment (KDHE). The sample locations are identified on Figure 3.
Shoreline sediment samples were collected from indicator sample location EEA.
Gamma isotopic analyses were performed on the samples. These samples were collected as part of a cooperative sampling effort with the KDHE. This sample location is identified on Figure 3.
Aquatic vegetation was collected from indicator sample locations DC ALT, EEA and MUDS.
Gamma isotopic analyses were performed on the aquatic vegetation samples. These samples were collected as part of a cooperative sampling effort with the KDHE. The sample locations are identified on Figure 3.
Terrestrial vegetation (grass) was sampled from the EEA and MUDS indicator sample locations.
Gamma isotopic analyses were performed on the grass samples.
These samples were collected as part of a cooperative sampling effort with the KDHE. The sample locations are identified on Figure 4.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 3 of 32
Soil was sampled from the EEA and MUDS indicator sample locations.
Gamma isotopic analyses were performed on the soil samples. These samples were collected as part of a cooperative sampling effort with the KDHE. The sample locations are identified on Figure 4.
A deer was sampled from indicator sample location R2.7. Gamma isotopic analysis and tritium analysis was performed on the deer sample.
This sample was collected as part of a cooperative sampling effort with the KDHE. The sample location is identified on Figure 4.
II. DISCUSSION OF RESULTS Analysis results for pathways are summarized in Appendix B using the format described in Radiological Assessment Branch Technical Position, Revision 1, November 1979 (NRC Generic Letter 79-065). Results for individual samples are listed in Appendix C.
A. Airborne Pathway Chart 1 graphically illustrates weekly gross beta results for the sample year for all of the airborne sample locations.
Chart 2 represents the gross beta historical airborne smoothed averages of indicator sample locations and control sample locations.
Charts 1 and 2 demonstrate how closely the indicator and control sample locations tracked together. Chart 2 reveals a seasonal cyclic trend; the gross beta values peak in the winter months (December or January) and decrease to a low point in the spring months (May or June).
This trend is expected and is attributed to seasonal meteorological changes, i.e., changes in prevailing winds and precipitation.
The gross beta results of 2013 were compared to pre-operational monitoring results of 1983 and 1984. The weekly gross beta analyses range for 1983 and 1984 was 0.0064 to 0.084 pCi/m 3.
The 2013 weekly gross beta analyses range for indicator locations was 0.009 to 0.050 pCi/mi3.
The 2013 weekly gross beta analyses range was lower than the 1983 and 1984 pre-operational range. Additionally, the annual mean for indicator locations for 2013 (0.026 pCi/m 3) was lower than the annual mean for 1983 (0.032 pCi/m 3).
The gross beta results for the indicator locations were also compared to the control location.
The annual mean for indicator locations for 2013 (0.026 pCi/m 3) was the same as the annual mean of the control location (0.026 pCi/m 3). The indicator location with the highest gross beta annual mean was location 49 (0.027 pCi/m 3) and was slightly higher than the annual mean of the control location (0.026 pCi/m 3).
Naturally occurring Be-7 activity was detected, as was the case during pre-operational monitoring. In 1984, the range for Be-7 detected activity was 0.024 to 0.211 pCi/m 3 for indicator locations and the annual mean for indicator locations was 0.069 pCi/m 3. In 2013, the range for Be-7 detected activity was 0.052 to 0.092 pCi/m 3 for indicator locations and the annual mean for indicator locations was 0.076 pCi/m 3. The annual mean of the indicator locations (0.076 pCi/m 3) was the same as the annual mean of the control location (0.076 pCi/m 3).
1-131 activity was not detected in the weekly analysis of charcoal filters at any location.
The AP 07B-004 required lower limits of detection were met. Plant-related activation, corrosion, or fission products were not detected during 2013 in airborne particulate and radioiodine filters and no unusual trends were noted.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 4 of 32
B. Direct Radiation Pathway Quarterly OSL dosimeter results for each location are shown in Table 3. Measured values have been converted to a standardized 90-day quarter.
The annual mean of indicator sample locations in 2013 was 18.7 mR per standardized 90-day quarter.
The annual mean of the control sample locations in 2013 was 19.5 mR per standardized 90-day quarter.
For pre-operational comparison, in 1981, the annual mean of indicator sample locations was 18.9 mR per standardized 90-day quarter and the annual mean for the control sample locations was 17.1 mR per standardized 90-day quarter.
It should be noted WCGS changed from thermoluminescence dosimeters (TLD) to optically stimulated luminescence (OSL) dosimeters in 2008.
The indicator sample location with the highest annual mean was 47 (24.2 mR per standardized 90-day quarter). The close proximity of location 47 to the Radwaste Building is likely the reason direct radiation levels are higher at this location.
Based upon Condition Report 00027489, improvements were made in measuring and subtracting transit dose in 2010. As expected, the OSL results have increased since 2010.
Chart 3 visibly displays the increase of the OSL results. Chart 3 also displays how closely the indicator and control location OSL dosimeter results are for 2013.
Chart 4 displays the TLD nearsite sample locations (1, 2, 7-9, 11-14, 18, 26, 27, 29, 30, 37 and
- 38) and the control sample locations (locations 39 and 48) for the preoperational years through 2007.
C. Waterborne Pathway (1) Surface Water Tritium, attributable to WCGS operation, was detected in surface water samples collected from the Coffey County Lake Spillway (SP) indicator sample location. The annual mean for detected tritium activity at the SP location was 11,100 pCi/L and the range was 9,295 to 13,170 pCi/L.
The detected tritium activity was below the'30,000 pCi/L AP 07B-004 reporting level. Chart 5 illustrates the yearly averages of surface water tritium data for the spillway (SP) location. Chart 5 indicates the average tritium concentration of the Coffey County Lake spillway (SP) location has reached equilibrium. Tritium activity was not detected in samples obtained from the control sample location (JRR).
During pre-operational radiological environmental monitoring, measured radiological activity was not detected in surface water samples.
The AP 07B-004 required lower limits of detection were met. Radionuclides were not detected by the gamma isotopic analyses or by Fe-55 analyses.
Tritium was the only activity detected during 2013 in surface water samples and no unusual trends were noted.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 5 of 32
(2) Ground Water The AP 07B-004 required lower limits of detection were met for 1-131, tritium and gamma isotopic analyses. Radioactivity was not detected in any ground water samples. No unusual trends were noted.
Plant-related activation, corrosion or fission products were not detected during 2013 in ground water samples.
(3) Drinking Water Gross beta activity was detected in drinking water samples collected from the indicator sample location and in samples collected from the control sample location. The annual mean of the indicator sample location gross beta activity (2.9 pCi/L) was lower when compared to the annual mean of the control sample location gross beta activity (3.1 pCi/L). The 2013 annual means of gross beta activity for both the indicator and control sample locations were lower than those of the pre-operational monitoring year of 1984. In 1984, the annual mean of the indicator sample location gross beta activity was 7.5 pCi/L and the annual mean of the control sample location gross beta activity was 6.4 pCi/L.
Chart 6 illustrates the drinking water gross beta results for the last five years and how closely the gross beta results compared for the indicator and control sample locations.
Radionuclides were not detected by the 1-131 or gamma isotopic analyses.
The AP 07B-004 required lower limits of detection were met. Plant-related activation, corrosion, or fission products were not detected during 2013 in drinking water samples and no unusual trends were noted.
(4) Shoreline Sediment Naturally occurring K-40 was detected in shoreline sediment samples collected from the DC (indicator sample location) and JRR (control sample location). K-40 was also detected during pre-operational shoreline sediment monitoring.
No other radionuclides were detected in the DC or JRR shoreline sediment samples during 2013.
The AP 07B-004 required lower limits of detection were met. Plant-related activation, corrosion, or fission products were not detected during 2013 in shoreline sediment samples and no unusual trends were noted.
D. Ingestion Pathway (1) Milk Milk was not collected during the sample year since no indicator locations within five miles of the plant were identified during the Land Use Census.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 6 of 32
(2) Fish Naturally occurring K-40 activity was detected in fish samples obtained from the CCL indicator sample location and in fish samples obtained from the JRR control sample location.
K-40 activity was also detected during pre-operational fish monitoring.
Fish samples were also analyzed for tritium. Fish samples collected from Coffey County Lake had tritium activity detected (7,743 pCi/kg annual mean).
The detected tritium activity was attributable to plant operation.
An adult consuming 21 kilograms of fish, at the maximum measured tritium concentration (8,852 pCi/kg), would receive a committed effective dose equivalent of 0.012 mRem.
Tritium activity was not detected in the control location samples collected from JRR.
No other radionuclides were detected in fish samples during 2013. The AP 07B-004 required lower limits of detection were met and no unusual trends were noted.
(3) Broadleaf Vegetation Gamma analyses of broadleaf vegetation samples obtained from indicator and control sample locations detected naturally occurring gamma emitters Be-7 and K-40. Be-7 and K-40 activity were also detected pre-operationally.
No other radionuclides were detected in broadleaf vegetation samples during the year.
The AP 07B-004 required lower limits of detection were met. Plant-related activation, corrosion, or fission products were not detected during 2013 in broadleaf vegetation samples no unusual trends were noted.
(4) Crop Samples Gamma analysis detected naturally occurring K-40 activity to be present in the samples collected from the indicator sample locations and in the samples collected from the control sample location. K-40 activity was also detected during pre-operational crop monitoring. K-40 was the only activity detected in the crop samples.
The AP 07B-004 required lower limits of detection were met. Plant-related activation, corrosion, or fission products were not detected during 2013 in crop samples and no unusual trends were noted.
E. Additional Samples Collected (not required by AP 07B-004)
(1) Bottom Sediment Gamma analysis detected naturally occurring K-40 activity to be present in the samples collected from the indicator sample locations and in the samples collected from the control sample location.
K-40 activity was also detected during pre-operational bottom sediment monitoring.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 7 of 32
Cs-137 activity was detected in twelve samples obtained from indicator locations (range 38 to 108 pCi/kg, dry). Cs-137 activity was also detected in one sample obtained from the control sample location (85 pCi/kg, dry).
Cs-137 activity was detected in pre-operational samples. The Cs-137 activity detected in 2013 indicator sample location bottom sediment samples was within the pre-operational range.
(Cs-137 activity detected in 1981 and 1982 was in the range of 79 to 953 pCi/kg. The decay corrected range of pre-operational Cs-1 37 activity detected is approximately 38 to 457 pCi/kg.)
The detected Cs-137 activity in the samples collected from the indicator sample locations was likely due to fallout since the measured activity is within the decay corrected range of pre-operational Cs-137 detected activity and Cs-137 activity has also been detected in samples collected at the control sample location.
Chart 7 plots the Cs-1 37 detected activity from the discharge cove indicator sample location and JRR control sample location bottom sediment samples. The detected Cs-137 activity measured from the discharge cove location reflects a decreasing trend. The Chart 7 trendline indicates Cs-137 activity detected at the JRR control location has also been decreasing. Chart 7 also displays that in recent years, the detected Cs-1 37 activity for the JRR and DC sample locations overlap.
Fe-55 activity was not detected in the fourteen samples obtained from indicator sample locations. No other radionuclides were detected in bottom sediment samples.
Plant-related activation, corrosion, or fission products were not detected during 2013 in bottom sediment samples and no unusual trends were noted.
(2) Aquatic Vegetation Gamma analyses of aquatic vegetation samples obtained from indicator sample locations detected naturally occurring gamma emitters Be-7 and K-40. Be-7 and K-40 activity were also detected during pre-operational monitoring.
No other radionuclides were detected in aquatic vegetation samples. Plant-related activation, corrosion, or fission products were not detected during 2013 in aquatic vegetation samples and no unusual trends were noted.
(3) Shoreline Sediment Naturally occurring K-40 activity was detected in the shoreline sediment samples obtained from the EEA indicator sample location.
K-40 activity was also detected during pre-operational monitoring.
Cs-137 activity (89.2 pCi/kg, dry) was detected in a shoreline sediment sample obtained from the EEA indicator sample location.
Cs-137 activity was also detected in pre-operational shoreline sediment samples. Cs-137 activity detected in shoreline sediment samples collected from the DC location from 1982 to 1984 was in the range of 224 to 437 pCi/kg, dry. The decay corrected range of pre-operational Cs-1 37 activity detected is approximately 115 to 218 pCi/kg, dry. The detected Cs-137 activity in the shoreline sediment sample was likely due to fallout since the results are lower than the pre-operational decay corrected range. Additionally, Cs-1 37 activity is routinely detected in soil and sediment samples collected from the control locations.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 8 of 32
No other radionuclides were detected in the EEA shoreline sediment samples. Plant-related activation, corrosion, or fission products were not detected during 2013 and no unusual trends were noted.
(4) Terrestrial Vegetation Naturally occurring Be-7 and K-40 activity were detected in terrestrial vegetation indicator location samples. No other radionuclides were detected in terrestrial vegetation. Plant-related activation, corrosion or fission products were not detected during 2013 in terrestrial vegetation samples and no unusual trends were noted.
(5) Soil Naturally occurring K-40 activity was detected in soil samples obtained from the indicator locations. K-40 activity was also detected during pre-operational soil monitoring.
Cs-137 activity (range 148 to 250 pCi/kg) was detected in soil samples obtained from the indicator locations.
Data was reviewed for soil samples collected pre-operationally.
The detected Cs-137 activity range from February of 1985 was 255 to 2,160 pCi/kg. The decay corrected range of pre-operational Cs-137 activity detected in soil is approximately 134 to 1,137 pCi/kg. The detected Cs-137 activity in soil sampled in 2013 is within the decay corrected pre-operational range and is likely due to fallout.
Plant-related activation, corrosion, or fission products were not detected during 2013 in soil samples and no unusual trends were noted.
(6) Deer Naturally occurring K-40 activity was detected in the deer sample obtained from the indicator location.
Tritium activity (251 pCi/kg) was also detected in the deer sample. The detected tritium activity was attributable to plant operation.
No other radionuclides were detected in the deer sample. No unusual trends were identified.
Ill. PROGRAM REVISIONS/CHANGES Based upon the 2012 Land Use Census Report, Revision 1, broadleaf vegetation sample location A-3 was added to AP 07B-004 and broadleaf vegetation sample location N-1 was changed to an alternate sample location.
AP 07B-004 was revised to update the description of dosimeter location 44 to Wilson Cadman Wildlife Education Area to match the recent name change.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 9 of 32
IV. PROGRAM DEVIATIONS Air Samples The following air sample locations failed to meet the requirement for "continuous sampler operation." As described in footnote (1) of procedure AP 07B-004, Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program), Table 5-1, deviations are permitted from the required sampling schedule due to malfunction of sampling equipment and other legitimate reasons. Discrepancies greater than five percent between Total Military Time and Total Digital Flow Meter Time, which resulted in a loss of air sample collected, are listed in the following table.
Location Sample Period Percent Explanation of DeviationlComments Discrepancy/
Condition Report Number Hours Unavailable 32 06/24/13 - 07/01/13 Unknown Power Outage!
Equipment Malfunction /
Condition Report 00071046 37 08/05/13 - 08/12/13 6.17%/10.42 Power Outage /
Equipment Operated as Expected /
Condition Report 00072632 Dosimeters During the third quarter, one dosimeter result was not received from the vendor processor for location 16.
The vendor processor performed an investigation and the dosimeter was not located at the vendor facility.
All of the other dosimeter results for the third quarter were received.
The results for the other two dosimeters at location 16 have been received; this meets the requirements of AP 07B-004. (Condition Report 00077756)
Ground Water Protection The following information is being provided in association with the Nuclear Energy Institute (NEI) Groundwater Protection Industry Initiative:
Describe offsite ground water or surface water sample results that exceeded the REMP reporting criteria that were voluntarily communicated to State/Local officials during the calendar year-None.
V. INTERLABORATORY COMPARISON PROGRAM Environmental, Inc., Midwest Laboratory was contracted to perform radiological analysis of environmental samples for WCNOC.
The lab participated in the intercomparison studies administered by Environmental Resources Associates.
Appendix A is the Interlaboratory Comparison Program Results for Environmental, Inc., Midwest Laboratory.
Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also contained in Appendix A.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 10 of 32
VI. COMPARISON TO THE RADIOACTIVE EFFLUENT RELEASE PROGRAM As described in the section discussing radioisotopes found in fish from Coffey County Lake, dose that may be received as a result of tritium released from WCGS is comparable with the theoretical doses calculated by the Radioactive Effluent Release Program.
The theoretical doses calculated by the Radioactive Effluent Release Program assume a person drinks the water from Coffey County Lake and eats the fish from Coffey County Lake. Based upon these assumptions the dose to man from both pathways was calculated to be 0.165 mRem for 2013.
Using sample data obtained from the REMP, an adult drinking 2 liters per day of surface water from Coffey County Lake, using the average tritium activity (11,100 pCi/L), would receive a committed effective dose equivalent of 0.507 mRem per year. For an adult eating 21 kg of fish per year from Coffey County Lake, using the average tritium activity (7,743 pCi/kg), would receive a committed effective dose equivalent of 0.010 mRem per year. Based upon the REMP results, the dose from both pathways was calculated to be 0.517 mRem per year.
It should be noted Coffey County Lake is not used as a drinking water source. Calculating the dose to man for tritium detected in the Coffey County Lake surface water is for comparison purposes only.
The tritium dose values are being compared on a qualitative basis. It is not expected that the annual doses, as calculated in the Radioactive Effluent Release Report, would compare directly to those calculated from the REMP. The Radioactive Effluent Release Report provides a "snap shot" of potential dose resulting from the year's releases.
The REMP data indicates the accumulated result of releasing tritium into the lake since the start of plant operation.
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 11 of 32
TABLE 1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM DESCRIPTION (SAMPLE COLLECTION SPECIFIED BY AP 07B-004)
EXPOSURE PATHWAY/
SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS (See Figures 1 & 5)
SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS AIRBORNE Radioiodine and Particulates Samples from six locations Continuous sampler operation with sample collection weekly, or more frequently if required, by dust loading.
Samples from locations near the site boundary in three sectors having the highest calculated annual average D/Q and one supplemental location (Locations 2, 18, 37, or 49 on Figure 1)
Analyze radioiodine canister weekly for 1-131 Analyze particulate filter weekly for gross beta activity; perform quarterly gamma isotopic analysis composite (by location)
Sample from the vicinity of a community having the highest calculated annual average D/Q (Location 32 on Figure 1, New Strawn)
Sample from a control location 9.5 to 18.5 miles distant in a low ranked D/Q sector (Location 53 on Figure 5) 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 12 of 32
TABLE I (Cont.)
EXPOSURE PATHWAY/
SAMPLE TYPE DIRECT RADIATION NUMBER OF SAMPLES AND SAMPLE LOCATIONS (See Figures 2 & 5) 40 routine monitoring stations with two or more dosimeters measuring dose continuously, placed as follows:
SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS Quarterly Gamma dose quarterly An inner ring of stations, one in each meteorological sector 0-3 mile range from the site (Locations 1, 7, 9, 11-13, 18, 26, 27, 29, 30, 37, 38, 46, 47, & 49 on Figure 2).
An outer ring of stations, one in each meteorological sector in the 3 to 5 mile range from the site (Locations 4, 5,15-17,19, 22-25, 32, 34-36, 50 & 51 on Figure 2). Four sectors
[A, B, G & J] contain an additional station (Locations 2, 8, 14 &
20).
The balance of the stations to be placed in special interest areas such as population centers (Locations 23, 32 & 52), nearby residences 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 13 of 32
TABLE I (Cont.)
EXPOSURE PATHWAY/
SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS DIRECT RADIATION (cont.)
(many locations are near a residence),
schools (Locations 23
& 52), Wilson Cadman Wildlife Education Area (44), CCL Public Fishing Area (46) and in two areas to serve as control stations 10-20 miles distant from the site (Locations 39 and 53 on Figure 5).
WATERBORNE (See Figure 3)
Surface Ground One sample upstream (Location JRR on Figure 3) and one sample downstream (Location SP on Figure 3).
Samples from one or two sources only if likely to be affected.
Monthly grab sample Quarterly grab sample Monthly gamma isotopic analysis and composite for tritium analysis quarterly Quarterly gamma isotopic analysis and tritium analysis Indicator samples at locations hydrologically down-gradient of the site (Locations C-10, C-49, F-1, G-2, J-1 and J-2 on Figure 3);
control sample at a location hydrologically upgradient of the site (Location B-12 on Figure 3).
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 14 of 32
TABLE 1 (Cont.)
EXPOSURE PATHWAY/
SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS WATERBORNE (cont.)
Drinking Shoreline Sediment Sample of municipal water supply at an indicator location downstream of the site (Location IO-DW on Figure 5); control sample from location upstream of the site (Location BW-1 5 on Figure 3).
One sample from the vicinity of Coffey County Lake discharge cove (Location DC on Figure 3); control sample from John Redmond Reservoir (Location JRR on Figure 3).
(See Figures 4 & 5)
Samples from milking animals at three indicator locations within 5 miles of the site having the highest dose potential (currently there are no locations producing milk for human consumption within 5 miles of the site); one sample from a control location greater than 10 miles from the site if indicator locations are sampled.
Monthly Composite Semiannually Monthly gamma isotopic analysis and gross beta analysis of composite sample. Quarterly tritium analysis of composites.
Semiannual gamma isotopic analysis INGESTION Milk Semimonthly April to November; monthly December-March Gamma isotopic analysis and 1-131 analysis of each sample 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 15 of 32
TABLE I (Cont.)
EXPOSURE PATHWAY/
SAMPLE TYPE NUMBER OF SAMPLES AND SAMPLE LOCATIONS SAMPLE COLLECTION FREQUENCY TYPE AND FREQUENCY OF ANALYSIS INGESTION (cont.)
Fish Indicator samples of 1 to 3 recreationally important species from Coffey County Lake; control samples of similar species from John Redmond Reservoir spillway (Figure 4).
Semiannually Gamma isotopic analysis on edible portions Broadleaf Vegetation Irrigated Crops Samples of available broadleaf vegetation from two indicator locations (using the criteria from the "Land Use Census" section) with highest calculated annual average D/Q (Locations A-3 and Q-6 and alternate locations B-i, H-2, N-1 and R-2 on Figure 4); sample of similar broadleaf vegetation from a control location 9.5 to 18.5 miles distant in a low ranked D/Q sector (Location D-2 on Figure 5).
Sample of crops irrigated with water from the Neosho River downstream of the Neosho River - Wolf Creek confluence (locations will vary from year to year, e.g.,
Location NR-D1 and NR-D2 on Figure 5).
Monthly when available At time of harvest Gamma isotopic analysis on edible portions Gamma isotopic analysis on edible portions 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 16 of 32
TABLE 2 SAMPLE LOCATION IDENTIFIERS, DISTANCES (Miles) AND DIRECTIONS (Sectors)
Sample Type Location Distance from Direction Sector Identifier Reactor Air Particulates and Radioiodine 2
2.7 N
A 18 3.0 SSE H
32 3.1 WNW P
37 2.0 NNW R
49 0.8 NNE B
53 10.8 ENE D
Dosimeters 1
1.4 N
A 2
2.7 N
A 4
4.0 NNE B
5 4.1 NE C
7 2.1 NE C
8 1.7 NNE B
9 2.0 ENE D
11 1.7 E
E 12 1.9 ESE F
13 1.6 SE G
14 2.5 SE G
15 4.6 ESE F
16 4.3 E
E 17 3.7 SE G
18 3.0 SSE H
19 3.9 SSE H
20 3.3 S
J 22 3.9 SSW K
23 4.3 SW L
24 4.1 WSW M
25 3.4 W
N 26 2.4 WSW M
27 2.2 SW L
29 2.7 SSW K
30 2.5 W
N 32 3.1 WNW P
34 4.4 NW Q
35 4.6 NNW R
36 4.2 N
A 37 2.0 NNW R
38 1.2 NW Q
39 13.1 N
A 41 0.8 NNW R
42 0.8 SSE H
43 0.7 WNW P
44 3.0 NNW R
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 17 of 32
TABLE 2 (Cont.)
SAMPLE LOCATION IDENTIFIERS, DISTANCES (Miles) AND DIRECTIONS (Sectors)
Sample Type Location Distance from Direction Sector Identifier Reactor Dosimeters 46 1.6 WNW P
47 0.16 S
J 49 0.8 NNE B
50 3.6 ENE D
51 4.3 S
J 52 3.6 SW L
53 10.8 ENE D
Surface Water JRR 3.7 W
Ground Water B-12 1.9 NNE B
C-10 2.7 W
N C-49/L-49 2.8 SW L
F-1 2.5 ESE F
G-2 3.6 SE G
J-1 3.8 S
J J-2 4.3 S
J Drinking Water BW-15 3.9 SW L
IO-DW 26.1 SSE H
Shoreline Sediment DC 0.8 WNW P
EEA 3.0 NNW R
JRR 3.6 W
N Fish CCL 0.6 E to NNW E to R JRR 3.7 W
N Food/Garden B-1 0.8 NNE B
D-2 14.8 ENE D
H-2 3.0 SSE H
Q-6 2.4 NW Q
Crops NR-D1 8.9 S
J NR-D2 11.5 S
J NR-U1 4.0 SSW K
Bottom Sediment DC 0.9 WNW P
EEA 3.0 NNW R
ESW 0.5 E
E JRR 3.7 W
N MUDS 1.5 WNW P
UHS 0.6 E
E Aquatic Vegetation DC ALT 1.5 NW Q
EEA 3.0 NNW R
MUDS 1.5 WNW P
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 18 of 32
TABLE 2 (Cont.)
SAMPLE LOCATION IDENTIFIERS, DISTANCES (Miles) AND DIRECTIONS (Sectors)
Sample Type Location Distance from Direction Sector Identifier Reactor Terrestrial Vegetation EEA 3.0 NNW R
MUDS 1.5 WNW P
Soil EEA 3.0 NNW R
MUDS 1.5 WNW P
Meat (Deer)
R2.7 2.7 NNW R
2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 19 of 32
TABLE 3 OSL Dosimeter Results mR/Standardized 90-day Quarter)
Location Qtr. I Qtr. 2 Qtr. 3 Qtr. 4 Total Annual mR)
(mR)
(mR)
(mR)
Exposure (mR) 1 19.1 19.6 21.5 21.8 81.9 2
17.8 18.3 18.5 19.4 74.1 4
19.1 20.5 21.4 20.6 81.7 5
17.8 17.2 14.6 17.2 66.9 7
17.5 17.0 18.9 19.2 72.6 8
20.3 18.8 21.7 22.5 83.3 9
18.5 19.2 15.9 17.3 71.0 11 20.1 23.1 19.6 20.6 83.4 12 20.7 20.5 20.1 21.2 82.5 13 20.7 20.4 18.5 17.3 76.9 14 17.5 20.1 18.0 17.8 73.4 15 19.1 18.8 17.8 17.8 73.4 16 17.0 16.2 17.3 16.9 67.3 17 18.2 20.4 17.5 20.9 76.9 18 17.8 20.1 15.4 19.7 72.9 19 20.6 21.8 18.5 20.9 81.9 20 18.0 17.5 18.5 19.5 73.5 22 18.0 18.8 19.6 22.0 78.3 23 15.9 17.0 21.7 20.0 74.6 24 18.4 20.9 19.6 19.5 78.4 25 17.3 16.3 17.3 17.3 68.3 26 18.3 16.6 16.8 19.5 71.2 27 19.2 19.2 20.7 17.7 76.7 29 14.8 14.0 14.3 16.1 59.2 30 19.4 14.9 19.2 21.5 75.1 32 18.4 16.1 17.1 18.3 69.8 34 20.6 17.9 19.2 20.8 78.5 35 19.6 19.2 18.5 20.5 77.8 36 19.6 18.3 19.9 20.0 77.8 37 17.3 16.6 15.3 18.8 68.0 38 19.4 20.1 18.5 21.1 79.1 39 19.6 18.7 17.9 15.4 71.5 41 18.4 20.6 19.4 18.3 76.7 42 13.0 12.7 12.4 12.8 51.0 43 12.4 12.8 12.3 12.5 50.0 44 15.9 20.5 18.5 20.6 75.5 46 18.3 19.2 18.9 20.6 77.0 47 20.4 24.8 24.1 27.6 96.9 49 19.4 16.1 17.5 18.7 71.8 50 20.0 22.2 20.9 19.2 82.3 51 20.1 19.7 21.7 20.4 81.9 52 20.6 20.1 18.2 17.7 76.5 53 20.9 20.7 21.5 21.3 84.3 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 20 of 32
FIGURE 1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 21 of 32
FIGURE 2 DIRECT RADIATION PATHWAY SAMPLING LOCATIONS
- = DOSIMETER LOCATIONS 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 22 of 32
FIGURE 3 WATERBORNE PATHWAY SAMPLING LOCATIONS
= DRINKING WATER 0 = GROUND WATER
- = BOTTOM SEDIMENT A = SURFACE WATER 0 = SHORELINE SEDIMENT
.= AQUATIC VEGETATION 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 23 of 32
FIGURE 4 INGESTION PATHWAY SAMPLING LOCATIONS A = FISH (JRR)
BROADLEAF VEGETATION
- = SOIL
- FISH (CCL)
TERRESTRIAL VEGETATION
=DEER 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 24 of 32
FIGURE 5 A
- - AIRMRE PARTIJ1.AT & RADIOIODINE 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page 25 of 32
CHART I 2013 Airborne Gross Beta Weekly Results a) a)E a) co 2O 0D 0.070 0.060 0.050 0.040 0.030 0.020 0.010 0.000 I
A I
+
0 k A4 V
-I 0
0 U
4 a
M M
2 I
I I
I 0
4 8
12 16 20 24 28 Week Number 32 36 40 44 48 52 2013 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 26 of 32
CHART 2 0.060 a)E 0
CU a)
CD 04 c'J 0
a)-C 00E (n) 0.050 0.040 0.030 0.020 0.010N\\R Q0
§ Z
\\
Smoothed Avg. Indicator Locations Smoothed Avg. Control Locations 2013 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 27 of 32
CHART 3 OSL Dosimeters - Indicator and Control Locations mR per Standardized 90-Day Quarter 24.0 22.0 20.0 18.0 16.0 S14.0 E
12.0 10.0 8.0 6.0 based upon Condition 4.0 J\\
P
%\\
C8 4V P
e P
I \\
1 J\\
N\\
I \\
11\\
I P
Year/Quarter Indicator Locations Standardized 90-Day Quarter (mR) Control Locations Standardized 90-Day Quarter (mR) 2013 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 28 of 32
CHART 4 Historical TLD Nearsite Locations and Control Locations 32.0 30.0 Elevated resul 28.0 longer expi 26.0 24.0 22.0 0
E4 20.0 A
A 18.0 f,.*
o..,
16.0 A*
14.0 A
A 12.01980 1982 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 Avg. of Nearsite Locations A
Avg. of Control Locations Moving Avg. of Nearsite Locations (2 period)
Moving Avg. of Control Locations (2 period) 2013 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 29 of 32
CHART 5 Coffey County Lake Surface Water Tritium Data 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000
.I-
-J 0 4-1987 1992 1997 2002 2007 2012 s-Yearly Average of Spillway Location Polynomial Trendline 2013 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 30 of 32
CHART 6 Drinking Water Gross Beta (5 years) 6 5
U) 2-
.- 4 0
0.
C--
om u3 00 2
1 N
Q N
N
'N Q M-LO (0 M-0 T C~) (0 N-'
C0 N
U
(
C M~ U) r-0)M M~ U) 0)M
~
o CD N)
N 0~ 0~ 0~ 0~ 0~ 0 NNN N
NZ~ N N
N Ný N
,q, N
O LO U)
M-U O
U) -
0)M M
U)
I-0)M I-BW1 5 (Control)
- I00W (Indicator)I 2013 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 31 of 32
CHART 7 Detected Cs-1 37 Activity in Bottom Sediment 1,000 900 800 700 600 6;
500 400 300 200 100 0
0 N-I tr r-M 0
N M
10 NI_
- 0)
C N
MO 1"
10 (0
NI_
M O N'-
Co
!2 cO CO CO O*
0M 0*
0
- 0) 0M M
0 0
0 0
0 0
0 0
0 1O 1O 0
co C) 00 oco 1O N
Co 10 1-N
~
0 10 (0
o 0M Co 0)
N-N 0
N N
0 0
N N
N 0
Q-N N
N NC-0 C0 0-Co co 00-
- 0) 10-V)
V-It O
(0 10 0
0 C
10 Co
-0 o) o T-
- 0) 0 )
0 0
0 0
0 0
0 03 0D 0D r"0
JRRCs-137 Polynomial Trendline (DC)
Polynomial Trendline (JRR) 2013 Annual Radiological Environmental Operating Report - Wolf Creek Generating Station Page 32 of 32
I Environmental, Inc.
7,*7II Midwest Laboratory 700 Landwehr Road
- Nodhorook. IL 60062-2310 phone (847) 564-0700- fax (847) 564-4517 APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE:
Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only.
January through December, 2013
Appendix A Interlaboratory Comparison Program Results Environmental, Inc., Midwest Laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of its quality control program in December 1971.
These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.
Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency.
Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.
Results in Table A-1 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.
Table A-2 lists results for thermoluminescent dosimeters (TLDs), via International Intercomparison of Environmental Dosimeters, when available, and internal laboratory testing.
Table A-3 lists results of the analyses on in-house "spiked" samples for the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.
Table A-4 lists results of the analyses on in-house "blank" samples for the past twelve months. Data for previous years available upon request.
Table A-5 lists REMP specific analytical results from the in-house "duplicate" program for the past twelve months. Acceptance is based on the difference of the results being less than the sum of the errors. Complete analytical data for duplicate analyses is available upon request.
The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program.
Results in Table A-7 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurement Laboratory Quality Assessment Program (EML).
Attachment A lists the laboratory precision at the 1 sigma level for various analyses. The acceptance criteria in Table A-3 is set at +/- 2 sigma.
Out-of-limit results are explained directly below the result.
Al
Attachment A ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION:
Analysis Gamma Emitters Strontium-89b ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSESa One standard deviation Level for single determination 5 to 100 pCi/liter or kg 5.0 pCi/liter
> 100 pCi/liter or kg 5% of known value 5 to 50 pCi/liter or kg 5.0 pCi/liter
> 50 pCi/liter or kg 10% of known value Strontium-90b Potassium-40 Gross alpha Gross beta Tritium Radium-226,-228 Plutonium Iodine-131, Iodine-1 2 9b Uranium-238, Nickel-63b Technetium-99b Iron-55b Other Analyses b 2 to 30 pCi/liter or kg
> 30 pCi/liter or kg
> 0.1 g/liter or kg
< 20 pCi/liter
> 20 pCi/liter
< 100 pCi/liter
> 100 pCi/liter 5 4,000 pCi/liter
> 4,000 pCi/liter
> 0.1 pCi/liter
>0.1 pCi/liter, gram, or sample
< 55 pCi/liter
> 55 pCi/liter
< 35 pCi/liter
> 35 pCi/liter 50 to 100 pCi/liter
> 100 pCi/liter 5.0 pCi/liter 10% of known value 5% of known value 5.0 pCi/liter 25% of known value 5.0 pCi/liter 5% of known value
+/-lG =
169.85 x (known) 0 0 933 10% of known value 15% of known value 10% of known value 6 pCi/liter 10% of known value 6 pCi/liter 15% of known value 10 pCi/liter 10% of known value 20% of known value a From EPA publication, "Environmental Radioactivity Laboratory Intercomparison Studies Program, Fiscal Year, 1981-1982, EPA-600/4-81-004.
b Laboratory limit.
A2
TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.
Concentration (pCi/L)
Lab Code Date Analysis Laboratory ERA Control Result b Result Limits Acceptance ERW-76 ERW-76 ERW-76 ERW-1 593 ERW-1593 ERW-1 596 ERW-1596 ERW-1 596 ERW-1 596 ERW-1596 ERW-1598 ERW-1598 ERW-1600 ERW-1600 ERW-1605 ERW-1605 ERW-1605 ERW-1606 ERW-6009 ERW-6009 ERW-6012 ERW-6012 ERW-6012 ERW-6012 ERW-6012 ERW-6015 ERW-6015 ERW-6019 ERW-6022 ERW-6022 d ERW-6022 ERW-6024 01/07/13 01/07/13 01/07/13 04/08/13 04/08/13 04/08/13 04108/13 04/08/13 04/08/13 04/08/13 04/08/13 04/08/13 04/08/13 04/08/13 04/08/13 04/08/13 04/08/13 04/08/13 10/07/13 10/07/13 10/07/13 10/07/13 10/07/13 10/07/13 10/07/13 10/07/13 10/07/13 10/07/13 10/07/13 10/07/13 10/07/13 10/07/13 Ra-226 Ra-228 Uranium Sr-89 Sr-90 Ba-1 33 Co-60 Cs-1 34 Cs-137 Zn-65 Gr. Alpha Gr. Beta 1-131 1-131(G)
Ra-226 Ra-228 Uranium H-3 Sr-89 Sr-90 Ba-1 33 Co-60 Cs-1 34 Cs-137 Zn-65 Gr. Alpha Gr. Beta 1-131 Ra-226 Ra-228 Uranium H-3 10.04 + 0.55 6.11 + 1.29 5.90 +/- 0.58 43.60 +/- 4.32 23.20 +/- 1.70 74.80 +/- 4.00 65.50 +/- 3.42 41.10 +/- 3.47 42.30 +/- 4.03 200.3 +/- 10.1 34.30 +/- 1.98 18.70 +/- 0.98 23.00 +/- 1.10 23.48 +/- 9.44 16.30 +/- 0.70 5.32 +/- 1.30 57.30 +/- 4.20 4041 +/- 194 22.00 +/- 2.80 17.10 +/- 2.55 48.20 +/- 4.29 100.8 +/-4.7 87.30 +/- 4.35 199.6 +/- 7.4 356.2 +/- 13.2 30.70 +/- 11.90 25.70 +/- 6.48 22.50 +/- 1.01 12.70 +/- 1.62 5.70 +/- 0.56 6.59 +/- 0.38 18397 +/-695 9.91 5.22 5.96 41.30 23.90 82.10 65.90 42.80 41.70 189.0 40.80 21.60 23.80 23.80 15.40 4.36 61.20 4050 21.90 18.10 54.20 102.0 86.70 206.0 333.0 42.80 32.20 23.60 12.10 4.02 6.24 17700 7.42-11.60 3.14 -6.96 4.47 -7.13 31.60 - 48.40 17.20 - 28.00 69.00 - 90.30 59.30 - 75.00 34.20 - 47.10 37.00 - 48.80 170.0 - 222.0 21.10 - 51.90 13.00 - 29.70 19.70 - 28.30 19.70 -28.30 11.50 - 17.70 2.54 -5.98 49.80 - 67.90 3450 - 4460 14.40 +/- 28.20 12.80 +/- 21.50 44.70 +/- 59.90 91.80 +/- 114.00 71.10 +/- 95.40 185.0 - 228.0 300.0 - 389.0 22.20 +/- 54.30 20.80 +/- 39.90 19.60 +/- 28.00 9.04 +/- 14.00 2.30 +/- 5.59 4.70 +/- 7.44 15500 - 19500 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass 8 Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing in drinking water conducted by Environmental Resources Associates (ERA).
b Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.
c Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.
d The reported result was obtained in the first cycle of counting. It can be positively biased due to extra beta counts contributed by Pb-214 and Bi-214 daughters of Rn-222. Result of second cycle of counting 4.47 pCi/L.
Al-1
TABLE A-2. Thermoluminescent Dosimetry, (TLD, CaSO4: Dy Cards).
mR Lab Code Date Known Lab Result Control Description Value
+/-12 sigma Limits Acceptance Environmental, Inc.
2013-1 5/6/2013 40 cm.
34.26 39.92 +/- 2.67 23.98 - 44.54 Pass 2013-1 5/6/2013 50 cm.
21.93 25.44 +/- 3.31 15.35 - 28.51 Pass 2013-1 5/6/2013 60 cm.
15.23 15.88 +/- 1.12 10.66 - 19.80 Pass 2013-1 5/6/2013 70 cm.
11.19 10.89 +/- 0.66 7.83 -14.55 Pass 2013-1 5/6/2013 80 cm.
8.57 9.21 +/- 0.41 6.00 -11.14 Pass 2013-1 5/6/2013 90 cm.
6.77 6.52 +/- 0.34 4.74 -8.80 Pass 2013-1 5/6/2013 100 cm.
5.48 5.02 +/- 0.53 3.84 -7.12 Pass 2013-1 5/6/2013 110 cm.
4.53 4.51 +/- 0.34 3.17 -5.89 Pass 2013-1 5/6/2013 120 cm.
3.81 4.28 +/- 0.35 2.67 -4.95 Pass 2013-1 5/6/2013 135 cm.
3.01 2.64 +/- 0.18 2.11 -3.91 Pass 2013-1 5/6/2013 150 cm.
2.44 2.10 +/- 0.25 1.71 -3.17 Pass 2013-1 5/6/2013 180 cm.
1.69 1.78 +/- 0.33 1.18 -2.20 Pass Environmental, Inc.
2013-2 11/18/2013 50 cm.
19.93 22.75 +/- 3.67 13.95 - 25.91 Pass 2013-2 11/18/2013 60 cm.
13.84 15.75 +/- 1.94 9.69 -17.99 Pass 2013-2 11/18/2013 70 cm.
10.17 11.24 +/- 0.88 7.12 -13.22 Pass 2013-2 11/18/2013 75 cm.
8.86 9.18 +/- 1.23 6.20 -11.52 Pass 2013-2 11/18/2013 80 cm.
7.79 7.81 +/- 1.10 5.45 -10.13 Pass 2013-2 11/18/2013 90 cm.
6.15 5.98 +/- 0.90 4.31 -8.00 Pass 2013-2 11/18/2013 100 cm.
4.98 5.13 +/- 0.73 3.49 -6.47 Pass 2013-2 11/18/2013 110 cm.
4.12 3.87 +/- 0.32 2.88 -5.36 Pass 2013-2 11/18/2013 120 cm.
3.46 3.11 +/- 0.39 2.42 -4.50 Pass 2013-2 11/18/2013 135 cm.
2.73 2.71 +/- 0.83 1.91 -3.55 Pass 2013-2 11/18/2013 150 cm.
2.21 2.11 +/- 0.63 1.55 -2.87 Pass 2013-2 11/18/2013 180 cm.
1.54 1.81 +/- 0.10 1.08 -2.00 Pass A2-1
TABLE A-3. In-House "Spiked" Samples Concentration (pCi/L)a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 c Activity Limits d Acceptance SPW-66 SPW-1891 SPSO-12313S SPMI-264 SPMI-264 SPMI-264 SPW-266 SPW-266 SPW-266 SPW-266 SPAP-376 SPAP-378 SPAP-378 SPW-391 SPW-380 W-30413 W-30413 W-30713 W-42713 W-42713 WW-2870 WW-2870 WW-2870 W-53113 SPAP-3332 SPW-3334 SPW-3458 SPAP-3529 SPAP-3529 SPAP-3531 SPF-3533 SPF-3533 SPW-3535 SPW-3537 SPW-3539 SPW-1 893 1/9/2013 1/18/2013 1/23/2013 1/25/2013 1/25/2013 1/25/2013 1/25/2013 1/25/2013 1/25/2013 1/25/2013 2/1/2013 2/1/2013 2/1/2013 2/1/2013 2/10/2013 3/4/2013 3/4/2013 3/7/2013 4/27/2013 4/27/2013 5/7/2013 5/7/2013 5/7/2013 5/31/2013 6/19/2013 6/19/2013 6/24/2013 6/27/2013 6127/2013 6/27/2013 6/27/2013 6/27/2013 6/27/2013 6/27/2013 6/27/2013 6/28/2013 Tc-99 Ra-228 Tc-99 Cs-1 34 Cs-1 37 Sr-90 Co-60 Cs-134 Cs-137 Sr-90 Gr. Beta Cs-1 34 Cs-137 H-3 Ni-63 Gr. Alpha Gr. Beta Ra-226 Gr. Alpha Gr. Beta Co-60 Cs-137 H-3 Ra-226 Am-241 Th-230 C-14 Cs-134 Cs-137 Gr. Beta Cs-134 Cs-137 Ni-63 Tc-99 Fe-55 Ra-228 1009 +/- 5 35.60 +/- 2.75 103.5 +/- 2.2 110.9 +/-6.7 82.84 +/- 7.47 38.19 +/- 1.49 46.89 +/- 4.68 105.9 +/- 8.0 42.17 +/- 5.65 39.84 +/- 1.65 44.20 +/- 0.11 3.71 +/- 0.65 97.47 +/- 2.50 63719 +/- 703 217.0 +/- 3.7 19.77 +/- 0.40 30.48 +/- 0.34 18.06 +/- 0.51 20.67 +/- 0.40 28.44 +/- 0.32 166.1 +/-7.4 161.2 +/-9.3 6853 +/- 250 16.83 +/- 0.41 4.60 +/- 0.14 4.36 +/- 0.34 3825 +/- 13 3.49 +/- 1.26 102.0 +/- 2.9 45.64 +/- 0.11 1.31 +/- 0.14 2.77 +/- 0.27 204.3 +/- 3.5 104.5 +/- 1.7 97015 +/- 860 30.16 -2.73 1078 30.85 107.8 107.5 77.48 40.11 44.48 107.5 39.49 40.11 45.68 3.87 102.9 65626 205.3 20.00 30.90 16.70 20.00 30.90 161.6 149.0 6735 16.70 4.00 4.00 4736 3.30 101.1 45.42 1.50 2.43 204.8 107.8 90677 30.85 754.9 - 1402.0 21.60 - 40.11 75.46 - 140.14 96.73 - 118.23 67.48 - 87.48 32.09 - 48.13 34.48 - 54.48 96.73 - 118.23 29.49 - 49.49 32.09 - 48.13 27.41 - 63.95 2.32 - 5.42 92.61 -113.19 52501 -78751 143.7 - 266.9 10.00 - 30.00 20.90 - 40.90 11.69 - 21.71 10.00 - 30.00 20.90 - 40.90 145.4 - 177.8 134.1 - 163.9 5388 - 8082 11.69 - 21.71 2.40 - 5.60 2.40 - 5.60 2842 - 6630 1.98 -4.62 90.99 -111.21 27.25 - 63.59 0.90 -2.10 1.46 - 3.40 143.4 - 266.2 75.46 - 140.14 72542 - 108812 21.60 - 40.11 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A3-1
TABLE A-3. In-House "Spiked" Samples Concentration (pCi/L)a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 c Activity Limits d Acceptance SPW-72913S SPW-4373 SPW-4373 SPW-4373 SPW-4374 SPMI-4376 SPMI-4376 SPMI-4376A W-73113 SPS-4514 W-82013 W-82013 SPW-1 894 W-90913 W-90913 WW-5623 WW-5623 WW-5623 WW-5750 WW-5750 WW-5750 W-102813 SPW-1898 W-122313 W-122313 7/29/2013 7/31/2013 7/31/2013 7/31/2013 7/31/2013 7/31/2013 7/31/2013 7/31/2013 7/31/2013 8/5/2013 8/20/2013 8/20/2013 8/28/2013 9/9/2013 9/9/2013 10/3/2013 10/3/2013 10/3/2013 10/3/2013 10/3/2013 10/3/2013 10/28/2013 12/17/2013 12/23/2013 12/23/2013 Tc-99 Cs-134 Cs-137 Sr-90 Sr-90 Cs-1 34 Cs-137 Sr-90 Ra-226 Sr-90 Gr. Alpha Gr. Beta Ra-228 Gr. Alpha Gr. Beta Co-60 Cs-1 37 H-3 Co-60 Cs-137 H-3 Ra-226 Ra-228 Gr. Alpha Gr. Beta 126.6 +/- 2.2 91.71 +/- 6.02 83.05 +/- 7.20 39.28 +/- 1.77 42.17 +/- 1.71 82.22 -7.23 83.31 - 8.29 35.00 +/- 1.63 17.61 +/- 0.41 78.63 +/- 2.95 21.53 +/- 0.45 28.03 +/- 0.32 32.49 +/- 3.00 19.08 +/- 0.51 32.12 +/- 0.35 157.0 +/-7.0 156.0 +/- 8.8 6590 +/- 245 87.00 +/- 7.80 82.30 +/- 7.80 6181 +/- 238 15.69 +/- 0.37 28.15 +/- 2.37 20.96 +/- 0.47 31.00 +/- 0.34 107.8 90.94 76.57 39.64 39.64 90.94 76.57 39.64 16.70 79.28 20.00 30.90 30.85 20.10 32.10 155.3 148.1 6322 77.40 78.80 6322 16.70 30.85 20.10 32.10 75.46 +/- 140.14 80.94 +/- 100.94 66.57 +/- 86.57 31.71 +/- 47.57 31.71 +/- 47.57 80.94 +/- 100.94 66.57 +/- 86.57 31.71 +/- 47.57 11.69 +/- 21.71 63.42 +/- 95.14 10.00 +/- 30.00 20.90 +/- 40.90 21.60 +/- 40.11 10.05 +/- 30.15 22.10 +/- 42.10 139.8 - 170.8 133.3 - 162.9 5058 - 7586 77.00 +/- 97.00 68.80 +/- 88.80 5058 - 7586 11.69 +/- 21.71 21.60 +/- 40.11 10.05 +/- 30.15 22.10 +/- 42.10 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass a Liquid sample results are reported in pCi/Liter, air filters( pCi/m 3), charcoal (pCi/charcoal canister), and solid samples (pCi/kg).
b Laboratory codes: W (Water), Ml (milk), AP (air filter), SO (soil), VE (vegetation), CH (charcoal canister), F (fish), U (urine).
c Results are based on single determinations.
d Control limits are established from the precision values listed in Attachment A of this report, adjusted to +/- 2s.
NOTE: For fish, Jello is used for the Spike matrix. For Vegetation, cabbage is used for the Spike matrix.
A3-2
TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)8 Lab Code Sample Date Analysisb Laboratory results (4.66a)
Acceptance Type LLD Activityc Criteria (4.66 a)
SPW-67 Water 1/9/2013 Tc-99 1.10 0.69 +/- 0.68 10 SPW-190 Water 1/18/2013 Ra-228 0.74 0.66 +/- 0.43 2
SPW-1901 Water 1/18/2013 Ra-228 0.74 0.66 +/-0.43 2
SPMI-263 Milk 1/25/2013 Sr-90 0.64 0.31 +/- 0.34 1
SPMI-263 Milk 1/25/2013 Sr-90 0.64 0.31 +/- 0.34 1
SPW-265 Water 1/25/2013 Co-60 2.86 2.10 +/- 1.72 10 SPW-265 Water 1/25/2013 Cs-134 2.98 2.25 +/- 1.57 10 SPW-265 Water 1/25/2013 Cs-1 37 2.71 0.44 +/- 1.61 10 SPW-266 Water 1/25/2013 Sr-90 0.72
-0.12 +/- 0.32 1
SPAP-375 Air Filter 2/1/2013 Gr. Beta 0.003 0.016 +/- 0.003 0.010 SPAP-377 Air Filter 2/1/2013 Co-60 2.31
-0.34 +/- 1.75 100 SPAP-377 Air Filter 2/1/2013 Cs-134 2.72 1.22 +/- 1.62 100 SPAP-377 Air Filter 2/1/2013 Cs-137 1.50
-0.52 +/- 1.80 100 SPW-391 Water 2/1/2013 H-3 92.04
-29.44 +/- 69.24 200 SPW-379 Water 2/10/2013 Ni-63 2.11 0.91 +/- 1.30 20 W-30413 Water 3/4/2013 Gr. Alpha 0.35 0.08 +/- 0.26 1
W-30413 Water 3/4/2013 Gr. Beta 0.73 0.10 +/- 0.51 3.2 W-30713 Water 3/7/2013 Ra-226 0.031 0.032 +/- 0.024 1
W-42713 Water 4/27/2013 Gr. Alpha 0.45
-0.14 +/- 0.30 1
W-42713 Water 4/27/2013 Gr. Beta 0.72
-0.23 +/- 0.50 3.2 W-53113 Water 5/31/2013 Ra-226 0.03 0.01 +/- 0.02 1
SPW-3335 Water 6/19/2013 Th-230 0.01 0.01 +/- 0.01 1
SPW-3459 Water 6/24/2013 C-14 10.89 10.44 +/- 6.82 200 SPAP-3528 Air Filter 6/27/2013 Cs-1 34 2.10
-0.98 +/- 1.11 100 SPAP-3528 Air Filter 6/27/2013 Cs-137 2.71
-0.24 +/- 1.36 100 SPAP-3530 Air Filter 6/27/2013 Gr. Beta 0.004 0.018 +/- 0.003 0.010 SPF-3532 Fish 6/27/2013 Cs-134 8.38
-1.39 +/- 5.69 100 SPF-3532 Fish 6/27/2013 Cs-137 8.37
-1.88 +/- 6.41 100 SPW-3534 Water 6/27/2013 Ni-63 2.47
-1.04 +/- 1.48 20 SPW-3536 Water 6/27/2013 Tc-99 1.15
-1.11 +/- 0.68 10 SPW-3538 water 6/27/2013 Fe-55 170.27
-17.50 +/- 102.70 1000 SPW-1903 Water 6/28/2013 Ra-228 0.85
-0.02 +/- 0.39 2
A4-1
TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysiso Laboratory results (4.66a)
Acceptance Type LLD Activityc Criteria (4.66 (Y)
SPW-72913B Water 7/29/2013 Tc-99 1.44
-0.33 +/- 0.87 10 SPW-4372 Water 7/31/2013 Co-60 1.41
-1.42 +/- 3.00 10 SPW-4372 Water 7/31/2013 Cs-134 3.68
-2.66 +/- 3.46 10 SPW-4372 Water 7/31/2013 Cs-137 3.53 0.29 +/- 3.31 10 SPMI-4375 Milk 7/31/2013 Co-60 3.92 2.65 +/- 2.26 10 SPMI-4375 Milk 7/31/2013 Cs-134 4.67 0.68 +/- 2.54 10 SPMI-4375 Milk 7/31/2013 Cs-137 4.79 1.30 +/-2.68 10 SPMI-4375 Milk 7/31/2013 Sr-90 0.57 0.32 +/- 0.30 1
W-73113 Water 7/31/2013 Ra-226 0.02 0.04 +/- 0.02 1
SPS-4515 Powder 8/5/2013 Sr-90 0.09
-0.01 +/- 0.04 1
W-82013 Water 8/20/2013 Gr. Alpha 0.42
-0.15 +/- 0.28 1
W-82013 Water 8/20/2013 Gr. Beta 0.74
-0.24 +/- 0.51 3.2 SPW-1904 Water 8/28/2013 Ra-228 0.96 0.85 +/- 0.56 2
CHW-90913 Water 9/9/2013 Gr. Alpha 0.25 0.20 +/- 0.29 1
CHW-90913 Water 9/9/2013 Gr. Beta 0.49
-0.18 +/- 0.53 3.2 CHW-102013 Water 10/20/2013 Gr. Alpha 0.29 0.24 +/-0.33 1
CHW-102013 Water 10/20/2013 Gr. Beta 0.54
-0.32 +/-0.54 3.2 W-102813 Water 10/28/2013 Ra-226 0.02 0.02 +/- 0.01 1
SPW-1908 Water 12/17/2013 Ra-228 0.69 0.55 +/- 0.39 2
CHW-122313 Water 12/23/2013 Gr. Alpha 0.25
-0.09 +/- 0.26 1
CHW-122313 Water 12/23/2013 Gr. Beta 0.48 0.05 +/- 0.53 3.2 CHW-122713 Water 12/27/2013 Gr. Alpha 0.28 0.04 +/- 0.31 1
CHW-122713 Water 12/27/2013 Gr. Beta 0.49
-0.33 +/- 0.53 3.2 a Liquid sample results are reported in pCi/Liter, air filters( pCi/m 3), charcoal (pCi/charcoal canister), and solid samples (pCi/kg).
b 1-131(G); iodine-131 as analyzed by gamma spectroscopy.
c Activity reported is a net activity result.
A4-2
TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)2 Averaged Lab Code Date Analysis First Result Second Result Result Acceptance CF-41, 42 CF-41, 42 SWT-8243, 8244 AP-8454, 8455 AP-8517, 8518 MI-62, 63 WW-151, 152 SG-107, 108 SG-107, 108 SG-130, 131 SG-130, 131 WW-277, 278 WW-256, 257 DW-40010, 40011 DW-40010, 40011 SWT-361, 362 DW-484, 485 S-945, 946 S-945, 946 S-340, 341 S-340, 341 AP-463, 464 MI-631, 632 WW-769, 770 DW-736, 737 SWU-790, 791 W-925, 926 AP-1034, 1035 MI-1076, 1077 CH-1118, 1119 WW-1221, 1222 P-1368, 1369 DW-40017, 40018 MI-1473, 1474 AP-2014, 2015 DW-40023, 40024 DW-40023, 40024 SWU-736, 737 AP-2035, 2036 BS-1680, 1681 SW-1638, 1639 1/212013 1/2/2013 1/2/2013 1/2/2013 1/3/2013 1/8/2013 1/8/2013 1/11/2013 1/11/2013 1/14/2013 1/14/2013 1/17/2013 1/22/2013 1/24/2013 1/24/2013 1/29/2013 1/29/2013 1/29/2013 1/29/2013 1/31/2013 1/31/2013 1/31/2013 2/13/2013 2/25/2013 2/26/2013 2/26/2013 2/27/2013 3/7/2013 3/13/2013 3/14/2013 3/14/2013 3/15/2013 3/19/2013 4/1/2013 4/1/2013 4/1/2013 4/1/2013 4/2/2013 4/2/2013 4/8/2013 4/9/2013 Gr. Beta Sr-90 Gr. Beta Be-7 Be-7 K-40 H-3 Ra-226 Ra-228 Ra-226 Ra-228 H-3 H-3 Ra-226 Ra-228 Gr. Beta Gr. Beta Cs-1 37 K-40 Cs-137 K-40 Be-7 K-40 Gr. Beta Gr. Beta Gr. Beta H-3 Be-7 K-40 1-131 (G)
H-3 H-3 Gr. Alpha K-40 Be-7 Ra-226 Ra-228 Gr. Beta Be-7 K-40 H-3 8.45 +/- 0.37 0.030 +/- 0.015 1.07 +/- 0.54 0.053 +/- 0.010 0.051 +/- 0.015 1317.70 +/- 91.70 222.70 +/- 81.00 55.20 +/- 5.53 71.60 +/- 1.10 3.91 +/- 0.20 2.40 +/- 0.33 159.71 +/- 77.91 502.70 +/- 93.40 2.55 +/- 0.18 1.78 +/- 0.62 0.90 +/- 0.40 14.85 +/- 1.93 14.50 +/- 0.18 7.90 +/- 0.74 0.16 +/- 0.05 17.35 +/- 1.34 0.27 +/- 0.10 1350.50 +/- 105.20 1.20 +/- 0.33 1.09 +/- 0.54 2.68 +/- 0.96 2265.00 +/- 153.00 0.17 +/- 0.08 1347.70 +/- 99.32 109.41 +/- 5.69 452.11 +/- 97.43 735.24 +/- 113.99 1.43 +/- 0.94 1618.00 +/- 107.00 0.055 +/- 0.008 2.29 +/- 0.18 2.99 +/- 0.69 4.80 +/- 0.95 0.070 +/- 0.013 1995.30 +/- 265.70 1350.77 +/- 130.08 7.90 +/- 0.35 0.029 +/- 0.014 0.98 +/- 0.51 0.042 +/- 0.010 0.049 +/- 0.017 1351.90 +/- 72.50 289.70 +/- 84.10 58.60 +/- 5.94 74.30 +/- 1.70 3.45 +/- 0.27 2.70 +/- 0.39 196.57 +/- 79.72 483.30 +/- 92.60 2.86 +/- 0.20 2.22 +/- 0.62 1.01 +/- 0.38 14.81 +/- 2.06 14.45 +/- 0.19 8.00 +/- 0.73 0.15 +/- 0.06 19.75 +/- 1.25 0.26 +/- 0.10 1413.70 +/- 85.94 1.35 +/- 0.34 1.57 +/- 0.58 2.08 +/- 0.95 2329.00 +/- 154.00 0.16 +/- 0.09 1396.10 +/- 108.00 103.88 +/- 7.76 403.29 +/- 95.46 666.04 +/- 111.41 1.61 +/- 1.00 1767.00 +/- 129.00 0.057 +/- 0.006 2.54 +/- 0.20 2.96 +/- 0.67 4.43 +/- 0.86 0.065 +/- 0.013 1992.00 +/- 289.40 1320.45 +/- 129.25 8.17 +/- 0.26 0.030 +/- 0.010 1.03 +/- 0.37 0.048 +/- 0.007 0.050 +/- 0.011 1334.80 +/- 58.45 256.20 +/- 58.38 56.90 +/- 4.06 72.95 +/- 1.01 3.68 +/- 0.17 2.55 +/- 0.26 178.14 +/- 55.73 493.00 +/- 65.76 2.71 +/- 0.13 2.00 +/- 0.44 0.96 +/- 0.28 14.83 +/- 1.41 14.48 +/- 0.13 7.95 +/- 0.52 0.15 +/- 0.04 18.55 +/- 0.92 0.26 +/- 0.07 1382.10 +/- 67.92 1.28 +/- 0.24 1.33 +/- 0.40 2.38 +/- 0.67 2297.00 +/- 108.54 0.17 +/- 0.06 1371.90 +/- 73.36 106.65 +/- 4.81 427.70 +/- 68.20 700.64 +/- 79.70 1.52 +/- 0.69 1692.50 +/- 83.80 0.056 +/- 0.005 2.42 +/- 0.13 2.98 +/- 0.48 4.62 +/- 0.64 0.068 +/- 0.009 1993.65 +/- 196.44 1335.61 +/- 91.69 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-1
TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance WW-2394, 2395 DW-40035,40036 DW-40035, 40036 MI-1825, 1826 MI-1825, 1826 DW-40049, 40050 WW-1 909,1910 DW-40064, 40065 DW-40066, 40067 DW-40066, 40067 F-2225, 2226 BS-2267, 2268 SG-2235, 2236 SG-2235,2236 SG-2235, 2236 AP-2288, 2289 WW-3091, 3092 SW-2373,2374 W-2352,2353 W-2352,2353 CF-2499, 2500 F-3987, 3988 BS-4113, 4114 SO-2902, 2903 SO-2902, 2903 SO-2902,2903 WW-2776, 2777 WW-2818, 2819 S-7271, 7272 S-7271, 7272 P-2923, 2924 WW-3133, 3134 WW-3049, 3050 DW-40079, 40080 DW-40079, 40080 DW-40089, 40090 DW-40091, 40092 DW-40091, 40092 DW-40103, 40104 MI-3154, 3155 P-3385, 3386 F-3776, 3777 F-3776, 3777 F-3776, 3777 4/9/2013 4/12/2013 4/12/2013 4/15/2013 411512013 4/15/2013 4/16/2013 4/23/2013 4/23/2013 4/23/2013 5/1/2013 5/1/2013 5/2/2013 5/2/2013 5/2/2013 5/2/2013 5/2/2013 5/8/2013 5/9/2013 5/9/2013 5/13/2013 5/20/2013 5/20/2013 5/22/2013 5/22/2013 5/22/2013 5/23/2013 5/23/2013 5/27/2013 5/27/2013 5/29/2013 6/1/2013 6/5/2013 615/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/5/2013 6/12/2013 6/14/2013 6/16/2013 6/16/2013 6/16/2013 H-3 Ra-226 Ra-228 K-40 Sr-90 Gr. Alpha H-3 Gr. Alpha Ra-226 Ra-228 K-40 K-40 Ac-228 Gr. Alpha Pb-214 Be-7 H-3 H-3 Ra-226 Ra-228 K-40 K-40 K-40 Th-228 Th-230 Th-232 H-3 H-3 Cs-1 37 K-40 H-3 H-3 H-3 Ra-226 Ra-228 Gr. Alpha Ra-226 Ra-228 Ra-226 K-40 H-3 Cs-1 37 Gr. Beta K-40 348.08 +/- 88.40 1.36 +/- 0.15 1.22 +/- 0.49 1290.20 +/- 113.80 0.68 +/- 0.32 1.88 +/- 0.69 2145.68 +/- 156.65 1.95 +/- 0.79 1.98 +/- 0.17 2.30 +/- 0.59 2.81 +/- 0.37 13.46 +/- 0.64 18.30 +/- 0.60 54.00 +/- 3.70 11.30 +/- 0.30 0.19 + 0.10 1107.91 + 153.49 324.80 +/- 86.81 0.91 + 0.20 1.28 + 0.87 11.52 0 0.45 3.07 +/- 0.48 8.06 +/- 0.44 0.57 +/- 0.07 0.39 +/- 0.06 0.55 +/- 0.07 261.76 +/- 100.85 999.35 +/- 126.15 2.82 +/- 0.10 21.52 +/- 0.97 441.31 +/- 92.75 278.42 +/- 86.54 156.08 +/- 79.16 6.67 +/- 0.30 5.55 +/- 0.75 6.82 +/- 0.90 3.44 +/- 0.19 3.70 +/- 0.68 0.98 +/- 0.22 1513.00 +/- 128.10 236.88 +/- 87.87 0.039 +/- 0.015 4.52 +/- 0.09 3.40 +/- 0.41 302.43 +/- 86.41 1.29 +/- 0.13 1.38 +/- 0.53 1378.60 +/- 91.99 0.46 +/- 0.31 2.51 +/- 0.71 2108.32 +/- 155.80 1.80 +/- 0.81 1.66 +/- 0.16 2.32 +/- 0.59 2.67 +/- 0.39 13.59 +/- 0.62 18.50 +/- 0.60 51.90 +/- 3.40 11.20 +/- 0.20 0.19 +/- 0.08 1263.37 +/- 157.43 364.61 +/- 88.53 1.29 +/- 0.22 1.03 +/- 0.94 12.55 +/- 0.61 3.05 +/- 0.43 7.99 +/- 0.44 0.51 +/- 0.06 0.40 +/- 0.05 0.62 +/- 0.06 283.17 +/- 101.68 880.63 +/- 122.43 2.91 +/- 0.09 21.13 +/- 1.02 374.30 +/- 89.94 209.45 +/- 83.44 244.66 +/- 83.86 7.03 +/- 0.35 6.11 +/- 0.77 5.64 +/- 1.02 3.66 +/- 0.19 4.69 +/- 0.73 0.62 +/- 0.15 1456.70 +/- 110.30 242.87 +/- 88.14 0.048 +/- 0.019 4.63 +/- 0.09 3.52 +/- 0.39 325.25 +/- 61.81 1.33 +/- 0.10 1.30 +/- 0.36 1334.40 +/- 73.17 0,57 +/- 0.22 2.20 +/- 0.50 2127.00 +/- 110.47 1.88 +/- 0.57 1.82 +/- 0.12 2.31 +/- 0.42 2.74 +/- 0.27 13.52 +/- 0.45 18.40 +/- 0.42 52.95 +/- 2.51 11.25 +/- 0.18 0.19 +/- 0.07 1185.64 +/- 109.94 344.71 +/- 62.00 1.10 +/- 0.15 1.16 +/- 0.64 12.04 +/- 0.38 3.06 +/- 0.32 8.02 +/- 0.31 0.54 +/- 0.05 0.40 +/- 0.04 0.59 +/- 0.05 272.46 +/- 71.61 939.99 +/- 87.90 2.86 +/- 0.07 21.32 +/- 0.70 407.80 +/- 64.60 243.93 +/- 60.11 200.37 +/- 57.66 6.85 +/- 0.23 5.83 +/- 0.54 6.23 +/- 0.68 3.55 +/- 0.13 4.20 +/- 0.50 0.80 +/- 0.13 1484.85 +/- 84.52 239.88 +/- 62.23 0.044 +/- 0.012 4.57 +/- 0.06 3.46 +/- 0.29 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-2
TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance S-3238, 3239 S-3238, 3239 S-3238, 3239 S-3238, 3239 SO-3343, 3344 SO-3343, 3344 DW-40118, 40119 DW-40118, 40119 DW-40118, 40119 WW-3583, 3584 AP-4092, 4093 E-3608, 3609 MI-3629, 3630 AP-4050, 4051 DW-40134, 40135 DW-40134, 40135 AP-4071, 4072 DW-40144, 40145 DW-40146, 40147 DW-40146, 40147 VE-3818, 3819 VE-3818, 3819 XW-4646, 4647 WW-4134, 4135 AP-4155, 4156 MI-4218, 4219 MI-4218, 4219 WW-4239, 4240 WW-4394, 4395 WW-4394, 4395 WW-4394, 4395 SWU-4478, 4479 DW-40159, 40160 DW-40159, 40160 VE-4436, 4437 VE-4436, 4437 G-4457, 4458 G-4457, 4458 G-4457, 4458 VE-4520, 4521 WW-4772, 4773 6/17/2013 6/17/2013 6/17/2013 6/17/2013 6/17/2013 6/17/2013 6/26/2013 6/26/2013 6/26/2013 6/27/2013 6/28/2013 7/1/2013 7/1/2013 7/1/2013 7/1/2013 7/1/2013 7/3/2013 7/9/2013 7/9/2013 7/9/2013 7/9/2013 7/9/2013 7/15/2013 7/16/2013 7/18/2013 7/22/2013 7/22/2013 7/23/2013 7/30/2013 7/30/2013 7/30/2013 7/30/2013 7/31/2013 7/31/2013 8/1/2013 811/2013 8/1/2013 8/1/2013 8/1/2013 8/1/2013 8/6/2013 Be-7 Cs-1 34 Cs-137 K-40 Cs-1 37 K-40 Gr. Alpha Ra-226 Ra-228 H-3 Be-7 K-40 K-40 Be-7 Ra-226 Ra-228 Be-7 Gr. Alpha Ra-226 Ra-228 Be-7 K-40 H-3 H-3 Be-7 K-40 Sr-90 H-3 Gr. Alpha Gr. Beta H-3 Gr. Beta Ra-226 Ra-228 Be-7 K-40 Be-7 Gr. Beta K-40 K-40 H-3 1139.80 +/- 215.00 26.23 +/- 13.23 72.75 +/- 25.99 21847.00 +/- 656.50 0.087 +/- 0.022 8.90 +/- 0.53 3.56 +/- 1.07 2.52 +/- 0.22 2.75 +/- 0.71 6732.57 +/- 246.74 0.078 +/- 0.015 1.28 +/- 0.13 1840.70 +/- 130.10 0.094 +/- 0.009 1.75 +/- 0.15 2.07 +/- 0.60 0.066 +/- 0.009 3.66 +/- 0.85 0.70 +/- 0.11 1.00 +/- 0.58 0.41 +/- 0.11 4.67 +/- 0.30 465.00 +/- 111.00 315.86 +/- 123.54 0.20 +/- 0.11 1426.80 +/- 117.50 0.62 +/- 0.32 223.71 +/- 92.64 2.63 +/- 1.49 3.72 +/- 1.17 271.50 +/- 91.30 2.07 +/- 0.54 3.39 +/- 0.63 3.29 +/- 0.73 0.98 +/- 0.21 3.95 +/- 0.39 0.78 +/- 0.19 6.15 +/- 0.14 4.25 +/- 0.36 2.20 +/- 0.16 143.80 +/- 86.70 1102.00 +/- 194.70 39.91 +/- 11.73 85.91 +/- 22.58 22158.00 +/- 622.80 0.084 +/- 0.017 9.47 +/- 0.49 4.51 +/- 0.96 2.48 +/- 0.19 2.86 +/- 0.75 6807.94 +/- 247.98 0.083 +/- 0.017 1.29 +/- 0.11 1804.90 +/- 143.00 0.093 +/- 0.009 1.56 +/- 0.15 1.61 +/- 0.57 0.069 +/- 0.011 2.85 +/- 0.79 0.72 +/- 0.11 0.70 +/- 0.52 0.46 +/- 0.18 4.52 +/- 0.43 525.00 +/- 114.00 264.98 +/- 121.78 0.16 +/- 0.09 1335.70 +/- 110.60 0.67 +/- 0.32 221.74 +/- 92.56 2.57 +/- 1.11 2.63 +/- 1.29 297.60 +/- 91.50 2.24 +/- 0.55 2.39 +/- 0.45 2.94 +/- 0.68 0.89 +/- 0.17 3.75 +/- 0.31 0.67 +/- 0.16 6.10 +/- 0.14 4.60 +/- 0.41 2.09 +/- 0.17 157.80 +/- 87.30 1120.90 +/- 145.03 33.07 +/- 8.84 79.33 +/- 17.21 22002.50 +/- 452.46 0.086 +/- 0.014 9.19 +/- 0.36 4.04 +/- 0.72 2.50 +/- 0.15 2.81 +/- 0.52 6770.26 +/- 174.91 0.080 +/- 0.011 1.28 +/- 0.09 1822.80 +/- 96.66 0.093 +/- 0.006 1.66 +/- 0.11 1.84 +/- 0.41 0.067 +/- 0.007 3.26 +/- 0.58 0.71 +/- 0.08 0.85 +/- 0.39 0.43 +/- 0.11 4.60 +/- 0.26 495.00 +/- 79.56 290.42 +/- 86.73 0.18 +/- 0.07 1381.25 +/- 80.68 0.65 +/- 0.23 222.73 +/- 65.48 2.60 +/- 0.93 3.18 +/- 0.87 284.55 +/- 64.63 2.16 +/- 0.39 2.89 +/- 0.39 3.12 +/- 0.50 0.94 +/- 0.14 3.85 +/- 0.25 0.72 +/- 0.12 6.13 +/- 0.10 4.42 +/- 0.27 2.15 +/- 0.12 150.80 +/- 61.52 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-3
TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)8 Averaged Lab Code Date Analysis First Result Second Result Result Acceptance VE-4709, 4710 VE-4709, 4710 VE-4709, 4710 VE-4709, 4710 WW-4562, 4563 SG-4651, 4652 SG-4651, 4652 SG-4651, 4652 VE-4835, 4836 WW-4877, 4878 LW-4856, 4857 W-4982, 4983 VE-4919, 4920 VE-4919, 4920 DW-40184, 40185 DW-40184, 40185 AP-5003, 5004 LW-5229, 5230 SS-5333, 5334 SS-5333, 5334 VE-5313, 5314 VE-5313, 5314 WW-5617, 5618 AP-5355, 5356 XW-5694, 5695 VE-5409, 5410 AP-5430, 5431 MI-5401, 5402 WW-5451, 5452 MI-5484, 5485 WW-5568, 5569 BS-5764, 5765 BS-5764, 5765 VE-5638, 5639 WW-5596, 5597 G-5680, 5681 G-5680, 5681 G-5680, 5681 S-5659, 5660 S-5659, 5660 S-5659, 5660 S-5659, 5660 AP-6345, 6346 AP-6366, 6367 8/8/2013 8/8/2013 8/8/2013 8/8/2013 8/8/2013 8/13/2013 8/13/2013 8/13/2013 8/13/2013 8/14/2013 8/15/2013 8/16/2013 8/19/2013 8/19/2013 8/19/2013 8/19/2013 8/22/2013 8/29/2013 9/3/2013 9/3/2013 9/3/2013 9/3/2013 9/5/2013 9/5/2013 9/8/2013 9/9/2013 9/12/2013 9/12/2013 9/12/2013 9/16/2013 9/17/2013 9/20/2013 9/20/2013 9/23/2013 9/23/2013 9/25/2013 9/25/2013 9/25/2013 9/26/2013 9/26/2013 9/26/2013 9/26/2013 9/30/2013 9/30/2013 Gr. Beta H-3 U-233/4 U-238 H-3 Gr. Alpha Gr. Beta Ra-226 K-40 H-3 Gr. Beta H-3 K-40 Be-7 Ra-228 Ra-228 Be-7 Gr. Beta Cs-1 37 K-40 K-40 Gr. Beta H-3 Be-7 C-14 K-40 Be-7 K-40 H-3 K-40 H-3 Cs-137 K-40 K-40 Gr. Beta Be-7 Gr. Beta K-40 Ac-228 Cs-137 K-40 Pb-214 Be-7 Be-7 31.40 +/- 1.00 1504.00 +/- 132.00 0.009 +/- 0.002 0.005 +/- 0.002 208.82 +/- 105.55 29.00 +/- 3.10 34.10 +/- 1.80 9.00 +/- 0.20 3.01 +/- 0.24 217.35 +/- 87.57 0.96 +/- 0.40 757.43 +/- 112.40 4891.90 +/- 407.90 470.50 +/- 159.60 2.35 +/- 0.72 1.44 +/- 0.35 0.23 +/- 0.10 1.09 +/- 0.86 89.20 +/- 41.60 11893.00 +/- 681.30 1.84 +/- 0.20 2.38 +/- 0.04 1987.00 +/- 147.00 0.22 +/- 0.12 0.94 +/- 0.09 3.60 +/- 0.26 0.26 +/- 0.10 1404.60 +/- 114.10 196.66 +/- 84.44 1398.50 +/- 88.93 274.69 +/- 87.95 0.40 +/- 0.03 17.97 +/- 0.59 4.15 +/- 0.33 5.97 +/- 1.39 0.36 +/- 0.13 3.81 +/- 0.11 3.23 +/- 0.32 1.19 +/- 0.21 0.13 +/- 0.04 16.08 +/- 1.39 0.97 +/- 0.15 0.077 +/- 0.010 0.078 +/- 0.012 30.70 +/- 1.00 1468.00 +/- 131.00 0.005 +/- 0.002 0.004 +/- 0.001 213.13 +/- 105.73 28.80 +/- 3.20 34.00 +/- 1.80 8.70 +/- 0.20 3.08 +/- 0.28 276.63 +/- 90.20 0.94 +/- 0.38 767.56 +/- 112.76 4907.40 +/- 350.40 325.10 +/- 104.10 2.53 +/- 0.70 2.30 +/- 0.56 0.21 +/- 0.10 2.28 +/- 0.96 97.80 +/- 34.60 12353.00 +/- 778.90 1.85 +/- 0.20 2.43 +/- 0.04 2094.00 +/- 150.00 0.27 +/- 0.14 0.78 +/- 0.10 3.33 +/- 0.29 0.26 +/- 0.10 1356.10 +/- 128.60 200.78 +/- 84.64 1364.60 +/- 113.30 203.72 +/- 84.71 0.37 +/- 0.02 17.54 +/- 0.55 4.46 +/- 0.38 5.95 +/- 1.45 0.35 +/- 0.09 3.77 +/- 0.11 2.99 +/- 0.24 1.06 +/- 0.21 0.14 +/- 0.05 16.65 +/- 1.46 1.10 +/- 0.16 0.081 +/- 0.008 0.083 +/- 0.014 31.05 +/- 0.71 1486.00 +/- 92.99 0.007 +/- 0.001 0.005 +/- 0.001 210.97 +/- 74.70 28.90 +/- 2.23 34.05 +/- 1.27 8.85 +/- 0.14 3.04 +/- 0.19 246.99 +/- 62.86 0.95 +/- 0.28 762.50 +/- 79.60 4899.65 +/- 268.87 397.80 +/- 95.27 2.44 +/- 0.50 1.87 +/- 0.33 0.22 +/- 0.07 1.69 +/- 0.64 93.50 +/- 27.05 12123.00 +/- 517.41 1.85 +/- 0.14 2.41 +/- 0.03 2040.50 +/- 105.01 0.25 +/- 0.09 0.86 +/- 0.07 3.46 +/- 0.19 0.26 +/- 0.07 1380.35 +/- 85.96 198.72 +/- 59.78 1381.55 +/- 72.02 239.20 +/- 61.05 0.39 +/- 0.02 17.76 +/- 0.40 4.31 +/- 0.25 5.96 +/- 1.01 0.35 +/- 0.08 3.79 +/- 0.08 3.11 +/- 0.20 1.13 +/- 0.15 0.14 +/- 0.03 16.37 +/- 1.01 1.04 +/- 0.11 0.079 +/- 0.006 0.081 +/- 0.009 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-4
TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance DW-5701, 5702 SG-5722, 5723 SG-5722, 5723 G-5806, 5807 G-5806, 5807 SG-5827, 5828 SG-5827, 5828 SG-5827, 5828 VE-5848, 5849 AP-6408, 6409 f-5954, 5955 P-6035, 6036 SG-6115, 6116 SG-6115, 6116 SG-6115, 6116 VE-6136, 6137 VE-6136, 6137 WW-6198, 6199 VE-6240, 6241 W-5996, 5997 W-5996, 5997 W-5996, 5997 DW-40224, 40225 DW-40224, 40225 WW-6219, 6220 CF-6261, 6262 CF-6261, 6262 MI-6303, 6304 VE-6534, 6535 S-6471, 6472 S-6471, 6472 S-6471, 6472 VE-6597, 6598 WW-6576, 6577 LW-6681, 6682 SWU-6765, 6766 WW-6849, 6850 MI-6786, 6787 SO-6744, 6745 SO-6744, 6745 SO-6744, 6745 SO-6744, 6745 SO-6744, 6745 SO-6744, 6745 SO-6744, 6745 SO-6744, 6745 9/30/2013 9/30/2013 9/30/2013 10/1/2013 10/1/2013 10/1/2013 10/1/2013 1011/2013 10/1/2013 10/3/2013 10/3/2013 10/7/2013 10/8/2013 10/8/2013 10/8/2013 10/8/2013 10/812013 10/8/2013 10/9/2013 10/9/2013 10/9/2013 10/9/2013 10/11/2013 10/11/2013 10/11/2013 10/14/2013 10/14/2013 10/14/2013 10/17/2013 10/18/2013 10/18/2013 10/18/2013 10/22/2013 10/22/2013 10/29/2013 10/29/2013 10/29/2013 10/30/2013 10/30/2013 10130/2013 10/30/2013 10/3012013 10/3012013 10/30/2013 10/30/2013 10/30/2013 Gr. Beta Ra-226 Ra-228 Be-7 K-40 Ac-228 K-40 Pb-214 K-40 Be-7 K-40 H-3 Ac-228 K-40 Pb-214 Be-7 K-40 H-3 K-40 Gr. Alpha Gr. Beta Ra-228 Ra-226 Ra-228 H-3 Be-7 K-40 K-40 K-40 Ac-228 K-40 Pb-214 K-40 H-3 Gr. Beta Gr. Beta H-3 K-40 Ac-228 Bi-214 Cs-1 37 Gr. Beta K-40 Pb-212 Ra-226 TI-208 14.48 +/- 2.04 12.41 +/-+0.47 7.84 +/- 0.71 3.26 +/- 0.30 6.65 +/- 0.21 4.08 +/- 0.33 2.55 +/- 0.65 3.82 +/- 0.17 1.62 +/- 0.16 0.072 +/- 0.015 2.74 +/- 0.36 198.41 +/- 85.00 5.22 +/- 0.50 5.61 +/- 1.08 4.29 +/- 0.24 0.55 +/- 0.18 2.78 +/- 0.35 12973.70 +/- 332.60 14.29 +/- 0.29 3.87 +/- 1.18 9.82 +/- 0.85 3.42 +/- 1.02 0.62 +/- 0.10 0.87 +/- 0.55 455.41 +/- 111.54 1.97 +/- 0.24 11.55 +/- 0.56 1507.30 +/- 110.80 15.96 +/- 0.17 0.94 +/- 0.19 12.82 +/- 1.05 0.88 +/- 0.11 2.46 +/- 0.22 745.60 +/- 110.70 2.00 +/- 0.92 3.07 +/- 0.61 863.00 +/- 113.80 1370.60 +/- 109.60 0.46 +/- 0.11 0.48 +/- 0.10 0.21 +/- 0.04 27.40 +/- 1.14 14.93 +/- 0.88 0.43 +/- 0.04 1.47 +/- 0.35 0.16 +/- 0.04 13.32 +/- 1.84 11.98 +/- 0.59 8.13 +/- 0.97 3.11 +/- 0.13 6.68 +/- 0.50 3.92 +/- 0.40 2.37 +/- 0.63 3.93 +/- 0.20 1.57 +/- 0.14 0.063 +/- 0.012 3.02 +/- 0.34 288.60 +/- 89.15 4.87 +/- 0.48 6.61 +/- 1.04 4.24 +/- 0.20 0.60 +/- 0.15 2.61 +/- 0.33 12757.80 +/- 330.00 14.95 +/- 0.54 4.07 +/- 1.08 8.53 +/- 0.82 3.39 +/- 1.01 0.76 +/- 0.10 1.00 +/- 0.54 354.66 +/- 107.84 2.06 +/- 0.22 12.06 +/- 0.61 1482.40 +/- 110.00 16.16 +/- 0.36 0.78 +/- 0.18 12.90 +/- 1.17 0.72 +/- 0.12 2.58 +/- 0.20 663.30 +/- 107.60 2.17 +/- 0.98 2.90 +/- 0.65 826.60 +/- 112.50 1449.20 +/- 105.50 0.51 +/- 0.11 0.30 +/- 0.10 0.24 +/- 0.04 27.44 +/- 1.11 15.20 + 0.90 0.40 +/- 0.05 1.31 + 0.36 0.16 +/- 0.04 13.90 +/- 1.37 12.20 +/- 0.38 7.99 +/- 0.60 3.19 +/- 0.16 6.67 +/- 0.27 4.00 +/- 0.26 2.46 +/- 0.45 3.88 +/-0.13 1.60 +/- 0.11 0.068 +/- 0.010 2.88 +/- 0.25 243.51 +/- 61.59 5.05 +/- 0.35 6.11 +/- 0.75 4.27 +/- 0.16 0.58 +/- 0.12 2.69 +/- 0.24 12865.75 +/- 234.27 14.62 +/- 0.31 3.97 +/- 0.80 9.18 +/- 0.59 3.41 +/- 0.72 0.69 +/- 0.07 0.94 +/- 0.39 405.03 +/- 77.57 2.01 +/- 0.16 11.80 +/- 0.41 1494.85 +/- 78.07 16.06 +/- 0.20 0.86 +/- 0.13 12.86 +/- 0.79 0.80 +/- 0.08 2.52 +/- 0.15 704.45 +/- 77.19 2.09 +/- 0.67 2.99 +/- 0.45 844.80 +/- 80.01 1409.90 +/- 76.06 0.48 +/- 0.08 0.39 +/- 0.07 0.23 +/- 0.03 27.42 +/- 0.80 15.07 +/- 0.63 0.42 +/- 0.03 1.39 +/- 0.25 0.16 +/- 0.03 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-5
TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance DW-40238, 40239 WW-7018, 7019 CF-6870, 6871 XW-6828, 6829 BS-6891, 6892 BS-6891, 6892 BS-6891, 6892 WW-6912, 6913 WW-6912, 6913 WW-6912, 6913 SO-6954, 6955 SO-6954, 6955 S-6976, 6977 DW-40246, 40247 CF-7102, 7103 DW-40250, 40251 DW-40250, 40251 WW-7164, 7165 SS-7334, 7335 WW-7558, 7559 LW-7292, 7293 W-7229, 7230 W-7229, 7230 SG-7313, 7314 SG-7313, 7314 SG-7313, 7314 W-7432, 7433 WW-7516, 7517 SG-7579, 7580 SG-7579, 7580 LW-7684, 7685 DW-40261, 40262 DW-40261, 40262 SWU-7663, 7664 10/31/2013 11/1/2013 1114/2013 11/4/2013 11/5/2013 11/5/2013 11/5/2013 11/5(2013 11/5/2013 11/5/2013 11/6/2013 11/6/2013 11/13/2013 11/15/2013 11/18/2013 11/18/2013 11/18/2013 11/19/2013 11/20/2013 11/22/2013 11/26/2013 12/1/2013 12/1/2013 12/2/2013 12/2/2013 12/2/2013 12/4/2013 12/10/2013 12/20/2013 12/20/2013 12/23/2013 12/27/2013 12/27/2013 12/30/2013 Ra-228 H-3 K-40 K-40 Cs-137 Gr. Beta K-40 Gr. Alpha Gr. Beta H-3 Cs-137 K-40 K-40 Gr. Alpha Be-7 Ra-226 Ra-228 H-3 K-40 H-3 Gr. Beta Ra-226 Ra-228 Ac-228 K-40 Pb-214 Gr. Beta H-3 Ra-226 Ra-228 Gr. Beta Ra-226 Ra-228 Gr. Beta 0.94 +/- 0.41 593.09 +/- 104.72 12.67 +/- 0.49 97.99 +/- 55.33 0.018 +/- 0.010 12.41 +/- 1.74 6.49 +/- 0.33 2.87 +/- 1.30 3.18 +/- 0.87 349.01 +/- 101.42 0.14 +/- 0.03 15.16 +/- 0.72 22.36 +/- 0.69 15.00 +/- 3.41 17.79 +/- 0.51 27.77 +/- 2.84 7.91 +/- 0.94 266.90 +/- 91.10 15.51 +/- 0.72 229.86 +/- 83.89 1.92 +/- 0.75 0.87 +/- 0.23 3.00 +/- 0.98 6.33 +/- 0.23 5.47 +/- 0.61 5.60 +/- 0.14 5.35 +/- 1.20 369.30 +/- 95.64 3.72 +/-0.11 2.38 +/- 0.18 0.84 +/- 0.51 0.54 +/- 0.10 1.09 +/- 0.51 2.85 +/- 0.71 1.60 +/- 0.55 648.69 +/- 106.89 13.30 +/- 0.47 160.21 +/- 74.99 0.018 +/- 0.009 9.97 +/- 1.57 6.28 +/- 0.40 4.46 +/- 1.47 3.18 +/- 0.87 430.14 +/- 98.06 0.12 +/- 0.02 14.11 +/- 0.64 22.62 +/- 0.72 20.31 +/- 4.00 18.09 +/- 0.80 26.15 +/- 2.67 6.32 +/- 0.84 268.90 +/- 91.20 14.14 +/- 0.80 191.77 +/- 82.05 2.38 +/- 0.77 0.88 +/- 0.25 3.27 +/- 1.16 6.69 +/- 0.30 6.24 +/- 0.74 5.37 +/- 0.16 3.89 +/- 1.23 269.22 +/- 91.35 3.85 +/- 0.30 2.77 +/- 0.44 1.96 +/- 0.61 0.67 +/- 0.10 1.12 +/- 0.43 3.88 +/- 0.77 1.27 +/- 0.34 620.89 +/- 74.82 12.98 +/- 0.34 129.10 +/- 46.60 0.018 +/- 0.007 11.19 +/- 1.17 6.39 +/- 0.26 3.67 +/- 0.98 3.18 +/- 0.62 389.58 +/- 70.54 0.13 +/- 0.02 14.64 +/- 0.48 22.49 +/- 0.50 17.65 +/- 2.63 17.94 +/- 0.48 26.96 +/- 1.95 7.12 +/- 0.63 267.90 +/- 64.45 14.83 +/- 0.54 210.82 +/- 58.67 2.15 +/- 0.54 0.88 +/- 0.17 3.14 +/- 0.76 6.51 +/- 0.19 5.86 +/- 0.48 5.49 +/- 0.11 4.62 +/- 0.86 319.26 +/- 66.13 3.79 +/- 0.16 2.58 +/- 0.24 1.40 +/- 0.40 0.61 +/- 0.07 1.11 +/- 0.33 3.37 +/- 0.52 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Note: Duplicate analyses are performed on every twentieth sample received in-house.
Results are not listed for those analyses with activities that measure below the LLD.
a Results are reported in units of pCi/L, except for air filters (pCi/Filter), food products, vegetation, soil, sediment (pCi/g).
A5-6
TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).
Concentration 8 Known Control Lab Code b Date Analysis Laboratory result Activity Limits c Acceptance MAAP-738 MAAP-738 MAAP-738 MAAP-738 MAAP-738 MAAP-738 MAAP-738 MAAP-738 MAAP-738 MAAP-738 MAAP-738 MAAP-738 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 Am-241 Co-57 Co-60 Cs-1 34 Cs-1 37 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 0.10 +/- 0.02 2.58 +/- 0.06 0.01 +/- 0.03 1.82 +/-0.13 2.93 +/-0.10 4.87 +/-0.13 0.12 +/- 0.02 0.11 +/-0.02 1.39 +/- 0.14 0.03 +/- 0.01 0.23 +/- 0.03 3.84 +/- 0.20 0.14 +/- 0.03 0.93 +/- 0.06 0.10 2.36 0.00 1.78 2.60 4.26 0.13 0.12 1.49 0.03 0.23 3.13 1.20 0.85 0.07 -0.14 1.65 - 3.07 NAC 1.25 -2.31 1.82 - 3.38 2.98 - 5.54 0.09 -0.17 0.09 -0.16 1.04-1.94 0.02 - 0.04 0.16 -0.30 2.19 -4.07 0.36 - 2.04 0.43 - 1.28 MAAP-738 8 02/01/13 Gr. Alpha MAAP-738 02/01/13 Gr. Beta MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 MAW-806 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 Am-241 Co-57 Co-60 Cs-1 34 Cs-137 Fe-55 H-3 K-40 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Zn-65 0.71 +/- 0.08 31.20 +/- 0.40 19.70 +/- 0.30 23.20 +/- 0.50 0.03 +/- 0.12 34.00 +/- 3.30 511.60 +/- 12.50 2.20 +/- 0.90 27.60 +/- 0.50 34.30 +/- 2.80 0.83 +/- 0.10 0.02 +/- 0.02 9.30 +/- 0.80 10.25 +/- 0.40 0.31 +/- 0.05 1.91 +/- 0.13 31.60 +/- 0.80 1.87 +/- 0.09 13.04 +/- 0.13 0.69 30.90 16.56 24.40 0.00 44.00 507.00 0.00 27.40 33.40 0.88 0.01 10.50 13.10 0.32 1.95 30.40 2.31 13.00 0.48 - 0.90 21.60 -40.20 13.69 - 25.43 17.10 - 31.70 NAC 30.80 - 57.20 355.00 - 659.00 NAc 19.20 -35.60 23.40 - 43.40 0.62 -1.15 NA d 7.40 - 13.70 9.20 - 17.00 0.22 - 0.41 1.37 -2.54 21.30 -39.50 0.69 - 3.93 6.50 - 19.50 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass MAW-811 02/01/13 Gr. Alpha MAW-811 02/01/13 Gr. Beta MAW-811 02/01/13 1-129 4.60 +/- 0.19 6.06 4.24 - 7.88 A6-1
TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).
Concentration a Known Control Lab Code b Date Analysis Laboratory result Activity Limits c Acceptance MASO-739 MASO-739 MASO-739 MASO-739 MASO-739 MASO-739 MASO-739 MASO-739 MASO-744 MASO-744 MASO-744 MASO-744 MASO-744 MASO-744 MASO-744 MAVE-747 MAVE-747 MAVE-747 MAVE-747 MAVE-747 MAVE-747 MASO-5043 MASO-5043 g MASO-5043 MASO-5043 MASO-5043 MASO-5043 MASO-5043 MASO-5043 MASO-5043 MASO-5043 MASO-5043 MASO-5043 MASO-5043 MASO-5043 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 02/01/13 08/01/13 08/01/13 08/01/13 08/01/13 08/01/13 08/01/13 08/01/13 08/01/13 08/01/13 08/01/13 08/01/13 08/01/13 08/01/13 08/01/13 Am-241 Co-57 Co-60 Cs-1 34 Cs-1 37 K-40 Mn-54 Zn-65 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Co-57 Co-60 Cs-134 Cs-1 37 Mn-54 Zn-65 Am-241 Co-57 Cs-1 34 Cs-1 37 K-40 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Zn-65 106.90 +/- 11.40 0.60 +/- 0.50 739.20 +/- 28.50 863.30 +/- 34.10 661.80 +/- 25.70 745.80 +/- 33.30 1.10 +/- 1.00 1109.60 +/- 44.10 682.60 +/- 16.80 0.20 +/- 0.90 88.30 +/- 9.00 408.40 +/- 14.00 380.50 +/- 16.80 53.20 +/- 4.80 242.10 +/- 10.20 10.37 +/- 0.17 6.48 +/- 0.17 0.02 +/- 0.04 7.79 +/- 0.21 0.00 +/- 0.05 7.29 +/- 0.33 1.40 +/- 1.70 699.60 +/- 3.90 1191.70 +/- 23.00 1072.00 +/- 5.10 760.00 +/- 16.20 753.80 +/- 4.90 560.00 +/- 23.70 68.40 +/- 7.50 0.40 +/- 0.80 383.90 +/- 14.50
-1.00 +/- 10.50 23.80 +/- 3.30 26.80 +/- 3.50
-351.50 +/- 5.50 113.00 0.00 691.00 887.00 587.00 625.30 0.00 995.00 670.00 0.52 79.50 628.00 444.00 62.50 281.00 8.68 5.85 0.00 6.87 0.00 6.25 0.00 0.00 1172.00 977.00 633.00 674.00 571.00 61.50 0.36 460.00 0.00 30.00 34.00 0.00 79.00 - 147.00 NA c 484.00 - 898.00 621.00 -1153.00 411.00 -763.00 437.70 -812.90 NA c 697.00 - 1294.00 469.00 - 871.00 NA d 55.70 - 103.40 440.00 - 816.00 311.00 - 577.00 43.80 -81.30 197.00 - 365.00 6.08 -11.28 4.10 -7.61 NA c 4.81 - 8.93 NA c 4.38 -8.13 NA c NA c 820.00 - 1524.00 684.00 - 1270.00 443.00 - 823.00 472.00 - 876.00 400.00 - 742.00 43.10 - 80.00 NA d 322.00 - 598.00 NAc 21.00 - 39.00 23.80 -44.20 NAC Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A6-2
TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).
Concentration a Known Control Lab Code b Date Analysis Laboratory result Activity Limits c Acceptance MAW-5052 08/01/13 1-129 2.75 +/- 0.20 3.79 2.65 -4.93 Pass MAW-5094 08/01/13 Am-241 0.00 +/- 0.01 0.00 NA Pass MAW-5094 08/01/13 Co-57 0.01 +/- 0.09 0.00 NA Pass MAW-5094 08/01/13 Co-60 23.20 +/- 0.32 23.58 16.51 - 30.65 Pass MAW-5094 08/01/13 Cs-134 27.60 +/- 0.58 30.40 21.00 - 39.00 Pass MAW-5094 08/01/13 Cs-137 32.31 +/-0.52 31.60 22.10 -41.10 Pass MAW-5094 08/01/13 Fe-55 39.20 +/- 3.50 53.30 37.30 - 69.30 Pass MAW-5094 08/01/13 Gr. Alpha 0.54 +/- 0.05 0.70 0.21 - 1.19 Pass MAW-5094 08/01/13 Gr. Beta 5.85 +/- 0.09 5.94 2.97 -8.91 Pass MAW-5094 08/01/13 H-3 1.20 +/- 3.00 0.00 NA c Pass MAW-5094 08/01/13 K-40 2.22 +/- 0.90 0.00 NA c Pass MAW-5094 08/01/13 Mn-54 0.01 +/- 0.11 0.00 NA c Pass MAW-5094 08/01/13 Ni-63 21.80 +/- 3.30 26.40 18.50 - 34.30 Pass MAW-5094 08/01/13 Pu-238 1.30 +/- 0.11 1.22 0.85 -1.58 Pass MAW-5094 08/01/13 Pu-239/40 0.98 +/- 0.09 1.00 0.70 -1.30 Pass MAW-5094 08/01/13 Sr-90 6.40 +/- 0.60 7.22 5.05 -9.39 Pass MAW-5094 08101113 Tc-99 13.10 +/- 0.70 16.20 11.30 - 21.10 Pass MAW-5094 08/01/13 U-233/4 0.08 +/- 0.02 0.07 NA d Pass MAW-5094 08/01/13 U-238 0.03 +/- 0.01 0.03 NA d Pass MAW-5094 08/01/13 Zn-65 35.30 +/- 0.90 34.60 24.20 - 45.00 Pass MAVE-5046 08/01/13 Co-57 0.01 +/- 0.03 0.00 NA c Pass MAVE-5046 08/01/13 Co-60 0.00 +/- 0.04 0.00 NA' Pass MAVE-5046 08/01/13 Cs-134 5.71 +/- 0.23 5.20 3.64 -6.76 Pass MAVE-5046 08/01/13 Cs-137 7.64 +/- 0.20 6.60 4.62 -8.58 Pass MAVE-5046 08/01/13 Mn-54 9.08 +/- 0.24 7.88 5.52 - 10.24 Pass MAVE-5046 08/01/13 Zn-65 2.92 +/- 0.25 2.63 1.84 -3.42 Pass A6-3
TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).
Concentration a Known Control Lab Code b Date Analysis Laboratory result Activity Limits '
Acceptance MAAP-5046 08/01/13 Am-241 0.01 +/- 0.02 0.00 NA C Pass MAAP-5046 08/01/13 Co-57 3.48 +/- 0.14 3.40 1.90 -3.50 Pass MAAP-5046 08/01/13 Co-60 2.44 +/- 0.08 3.40 1.60 -3.00 Pass MAAP-5046 08/01/13 Cs-134 0.01 +/- 0.03 0.00 NA c Pass MAAP-5046 08/01/13 Cs-137 3.09 +/- 0.13 2.70 1.90 -3.50 Pass MAAP-5046 08/01/13 Gr. Alpha 0.28 +/- 0.04 0.90 0.27-1.53 Pass MAAP-5046 08/01/13 Gr. Beta 1.90 +/- 0.08 1.63 0.82 -2.45 Pass MAAP-5046 08/01/13 Mn-54 3.95 +/- 0.12 3.50 2.50 -4.60 Pass MAAP-5046 08/01/13 Pu-238 0.14 +/- 0.028 0.12 0.087 -0.16 Pass MAAP-5046 08/01/13 Pu-239/40 0.10 +/- 0.022 0.092 0.064 -0.12 Pass MAAP-5046 08/01/13 Sr-90 1.69 +/- 4.10 1.81 1.27 -2.35 Pass MAAP-5046 h 08/01/13 U-233/4 0.04 +/- 0.01 0.03 0.02 -0.04 Fail MAAP-5046 08/01/13 U-238 0.19 +/- 0.027 0.21 0.14 -0.27 Pass MAAP-5046 08/01/13 Zn-65 3.27 +/- 0.18 2.70 2.50 -4.60 Pass a Results are reported in units of Bq/kg (soil), Bq/L (water) or Bq/total sample (filters, vegetation).
b Laboratory codes as follows: MAW (water), MAAP (air filter), MASO (soil), MAVE (vegetation).
c MAPEP results are presented as the known values and expected laboratory precision (1 sigma, 1 determination) and control limits as defined by the MAPEP. A known value of "zero" indicates an analysis was included in the testing series as a "false positive". MAPEP does not provide control limits.
d Provided in the series for "sensitivity evaluation". MAPEP does not provide control limits.
0 The filter was recounted overnight, no significant alpha activity could be detected.
tThe sample was reanalyzed using additional fuming nitric separations. Result of reanalysis: 574.4 +/- 35.2 Bq/kg.
g Interference from Eu-1 52 resulted in misidentification of Co-57.
h Result of repeat analysis: 0.031 +/- 0.013 pCi/filter.
A6-4
TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.
Concentration (pCi/L) b Lab Code b Date Analysis Laboratory ERA Control Result c Result d Limits Acceptance ERAP-1 174 ERAP-1 174 ERAP-1174 ERAP-1 174 ERAP-1 174 ERAP-1 174 ERAP-1 174 ERAP-1 174 ERAP-1 174 ERAP-1 174 ERAP-1 174 ERAP-1 174 ERAP-1175 ERAP-1 175 ERSO-1176 ERSO-1176 ERSO-1 176 ERSO-1176 ERSO-1176 ERSO-1176 ERSO-1176 ERSO-1 176 ERSO-1 176 ERSO-1176 ERSO-1 176 ERSO-1176 ERSO-1 176 ERSO-1 176 ERSO-1176 ERSO-1 176 ERSO-1 176 ERSO-1 176 ERSO-1 176 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 Am-241 Co-60 Cs-1 34 Cs-1 37 Fe-55 Mn-54 Pu-238 Pu-239/40 U-233/4
- U-238 Uranium Zn-65 Gr. Alpha Gr. Beta Am-241 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Uranium Ac-228 Bi-212 Bi-214 Co-60 Cs-134 Cs-1 37 K-40 Mn-54 Pb-212 Pb-214 Th-234 Zn-65 65.2 +/- 4.4 226.5 +/- 4.1 1101.2 +/- 23.6 1065.6 +/- 21.4 178.8 +/- 88.0
<3.1 50.0 +/- 3.0 65.7 +/- 2.6 54.0 +/- 2.5 55.6 +/- 2.6 112.0 +/-5.6 236.6 +/- 13.8 52.3 +/- 2.8 36.2 +/- 2.0 293.1 +/- 97.4 909.0 +/- 180.0 432.0 +/- 120.0 8050.8 +/- 376.0 1662.6 +/- 150.0 1682.8 +/- 160.0 3404.0 +/- 330.5 1335.0 +/- 132.0 1420.0 +/- 311.0 2626.0 +/- 60.0 7951.0 +/- 45.4 5785.0 +/- 51.0 6106.0 +/- 47.9 11756.0 +/- 284.3
< 28.0 1096.0 +/- 29.1 2875.0 +/- 60.0 2404.0 +/- 218.3 1542.0 +/- 56.4 66.8 214.0 1110.0 940.0 225.0 0.0 51.1 65.2 59.4 58.9 121.0 199.0 42.3 25.1 229.0 788.0 366.0 8530.0 1920.0 1900.0 3920.0 1240.0 1240.0 3660.0 7920.0 6370.0 6120.0 10300.0 0.0 1240.0 3660.0 1900.0 1400.0 41.2 -90.4 166.0 - 267.0 706.0 - 1380.0 706.0 - 1230.0 69.8 - 440.0 0.0 - 50.0 34.3 - 65.9 47.2 - 85.2 36.8 - 89.6 38.1 -81.4 67.0 - 184.0 142.0 - 275.0 14.2 - 65.7 15.9 -36.6 134.0 - 297.0 474.0 - 1090.0 239.0 - 506.0 3250.0 - 13500.0 1170.0 - 2460.0 1180.0 - 2410.0 2130.0 - 5170.0 795.0 - 1720.0 330.0 - 1820.0 2200.0 - 5270.0 5360.0 - 10900.0 4160.0 - 7650.0 4690.0 - 7870.0 7520.0 - 13800.0 0.0 - 1000.0 812.0 - 1730.0 2140.0 - 5460.0 601.0 - 3570.0 1110.0 - 1860.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A7-1
TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)".
Concentration (pCi/L) b Lab Code b Date Analysis Laboratory ERA Control Result c Result d Limits Acceptance ERVE-1 180 ERVE-1 180 ERVE-1 180 ERVE-1 180 ERVE-1 180 ERVE-1 180 ERVE-1 180 ERVE-1 180 ERVE-1 180 ERVE-1 180 ERVE-1 180 ERVE-1 180 ERVE-1180 ERVE-1 180 ERW-1 184 ERW-1184 ERW-1184 ERW-1184 ERW-1184 ERW-1184 ERW-1184 ERW-1184 ERW-1184 ERW-1184 ERW-1184 ERW-1184 ERW-1184 ERW-1 186 ERW-1186 ERW-1188 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 03/18/13 Am-241 Cm-244 Co-60 Cs-1 34 Cs-137 K-40 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Uranium Zn-65 Am-241 Co-60 Cs-1 34 Cs-137 Fe-55 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Uranium Zn-65 Gr. Alpha Gr. Beta H-3 569.8 +/- 81.7 1260.9 +/- 107.3 2130.5 +/- 48.0 1296.5 +/- 68.0 600.1 +/- 34.3 34078.0 +/- 787.0
< 28.7 2476.5 +/- 259.4 2659.3 +/- 273.2 3809.7 +/- 420.5 2460.6 +/- 205.0 2319.1 +/- 189.6 4866.3 +/- 375.6 1052.5 +/- 82.1 114.5 +/-8.1 2221.8 +/- 17.0 1309.4 +/- 58.4 1865.9 +/- 22.0 503.1 +/- 105.0
< 9.4 98.4 +/- 5.6 184.5 +/- 7.7 125.7 +/-6.0 44.9 +/- 3.4 46.5 +/- 3.5 93.3 +/- 7.1 412.8 +/- 32.0 109.1 +/-5.7 74.5 +/- 6.4 12279.0 +/- 319.0 553.0 1340.0 1920.0 1240.0 544.0 31900.0 0.0 1980.0 2260.0 3840.0 2460.0 2440.0 5010.0 878.0 118.0 2270.0 1400.0 1880.0 712.0 0.0 98.8 185.0 137.0 48.8 48.4 99.5 384.0 130.0 78.9 12300.0 338.0 - 735.0 657.0 -2090.0 1320.0 - 2680.0 797.0 - 1610.0 394.0 - 757.0 23000.0 - 44800.0 0.0 - 300.0 1180.0 -2710.0 1390.0 -3110.0 2190.0 - 5090.0 1620.0 - 3160.0 1630.0 -3100.0 3390.0 - 6230.0 633.0 - 1230.0 79.5 -158.0 1970.0 - 2660.0 1030.0 -1610.0 1600.0 -2250.0 424.0 - 966.0 0.0 - 100.0 73.1 -123.0 144.0 -233.0 89.2 -181.0 36.7 -62.9 36.9 - 59.4 73.1 -129.0 320.0 - 484.0 46.2 -201.0 45.2 -117.0 8240.0 - 17500.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass a Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurements Laboratory Quality Assessment Program (EML).
Laboratory codes as follows: ERW (water), ERAP (air filter), ERSO (soil), ERVE (vegetation). Results are reported in units of pCi/L, except for air filters (pCi/Filter), vegetation and soil (pCi/kg).
Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.
d Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA. A known value of "zero" indicates an analysis was included in the testing series as a "false positive". Control limits are not provided.
A7-2
Appendix B Summary Tables in the format of NRC Radiological Assessment Branch Technical Position Revision 1, November 1979 Page B-1
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
SUMMARY
Name of Facility: Wolf Creek Generating Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2013 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection
- Mean (f)
Distance and
- Mean (f)
- Mean (f)
Reported Measurement)
(LLD)
- Range Direction
- Range
- Range Measurements **
Air Particulate (pCi/m 3)
Gross Beta (318) 0.01 0.026 (265/265)
(0.009 - 0.050) 49 0.8 miles NNE 32 3.1 miles WNW 0.027 (53/53)
(0.013 - 0.050) 0.081 (4/4)
(0.070 - 0.088)
Station 53 0.026 (53/53)
(0.011 - 0.052) 0.076 (4/4)
(0.063 - 0.087) 0 Gamma (24)
Be-7 0.076 (20/20)
(0.052 - 0.092) 0 Air Radioiodine (pCi/mi3)
Direct Radiation Dosimeters (mR per std.
90-day Qtr.)
Surface Water (pCi/I)
Station 53
- (0/53) 1-131 (318) 0.07
-(0/265)
N/A N/A 0
Stations 39 & 53 Gamma Dose (172)
Gamma (24)
Tritium (24)
Fe-55 (8) 1-131 (32)
Gamma (32)
Tritium (32) 18.7 (164/164)
(12.3 - 27.6) 47 0.16 miles S 24.2 (4/4)
(20.4 - 27.6) 19.5 (8/8)
(15.4 - 21.5) 0
- (0/12)
N/A N/A 3,000 11,100 (12/12)
(9,295-13,170)
SP 3.2 miles SSE 11,100 (12/12)
(9,295-13,170)
JRR
- (0/12)
- (0/12)
- (0/4)
- (0/4)
Ground Water (pCi/I) 1
- (0/28)
N/A N/A N/A N/A N/A N/A N/A N/A B-12
- (0/4)
- (0/4)
- (0/4) 0 0
0 0
0 0
- (0/28) 2,000
- (0/28)
Page B-2
- Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
SUMMARY
Name of Facility: Wolf Creek Generating Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2013 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection
- Mean (f)
Distance and
- Mean (f)
- Mean (f)
Reported Measurement)
(LLD)
- Range Direction
- Range
- Range Measurements **
Drinking Water (pCi/I) 1-131 (24)
Gross Beta (24)
Gamma (24) 1
-(0/12) 4 2.9 (12/12)
(2.0 - 4.0)
- (0/12) 2,000
-(0/4) 9,209 (4/4)
(6,368 - 11,893)
N/A 1O-DW 26.1 miles SSE N/A BW-1 5
- (0/12) 3.1 (12/12)
(2.2-4.0) 2.9 (12/12)
(2.0-4.0)
N/A N/A N/A N/A
- (0/12)
- (0/4)
Tritium (8)
Gamma (6) 0 0
0 0
0 0
Shoreline Sediment (pCi/kg dry)
JRR 11,994 (2/2)
(10,926-13,061)
K-40 EEA 3.0 miles NNW EEA 3.0 miles NNW 11,557 (2/2)
(11,221-11,893)
Cs-1 37 180 89(1/4) 89 (1/2)
- (0/2)
Fish (pCi/kg wet)
Gamma (16)
JRR 3,416 (6/6)
(2,990 - 3,669)
K-40 3,129 (10/10)
(2,698 - 3,690) 7,743 (10/10)
(6,985 - 8,852)
CCL 0.6 miles E to NNW CCL 0.6 miles E to NNW 3,129 (10/10)
(2,698 - 3,690) 7,743 (10/10)
(6,985 - 8,852) 0 Tritium (16)
- (0/6) 0 Page B-3
- Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
SUMMARY
Name of Facility: Wolf Creek Generating Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2013 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection
- Mean (f)
Distance and
- Mean (f)
- Mean (f)
Reported Measurement)
(LLD)
- Range Direction
- Range
- Range Measurements **
Food and Garden (pCi/kg wet)
Gamma (18)
Be-7 K-40 657 (11/12)
(281 - 1,691) 5,346 (12/12)
(4,689 - 6,915)
Q-6 2.4 miles NW H-2 3.0 miles SSE 1,031 (2/2)
(372-1,691) 5,640 (4/4)
(5,157 - 6,915)
D-2 756 (5/6)
(397 - 1,259) 5,871 (6/6)
(4,719 - 6,804) 0 0
NR-U1 Crops (pCi/kg wet)
Bottom Sediment (pCi/kg dry)
Gamma (4)
K-40 14,612 (2/2)
(12,882-16,342)
NR-D1 8.9 miles S 16,342 (1/1)
Gamma (19) 7,606 (2/2)
(2,544 - 12,669)
JRR 12,206 (2/2)
(11,660 - 12,752) 0 K-40 10,118 (17/17)
(5,110- 12,602)
EEA 3.0 miles NNW 11,461 (2/2)
(11,346-11,576) 0 Cs-137 72(12/17)
DC 93(2/2) 85(1/2) 0 (38-108) 0.9 miles WNW (90-97)
Fe-55 (14)
-(0/14)
N/A N/A 0
Page B-4
- Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
SUMMARY
Name of Facility: Wolf Creek Generatinq Station Docket No.: 50-482 Location of Facility: Coffey County, Kansas Reporting Period: Annual 2013 Medium of ODCM All Indicator Indicator Location with Control Locations Pathway Analysis and Lower Locations Highest Annual Mean Number of Sampled Total Number of Limit of Name Nonroutine (Unit of Analysis Performed Detection
- Mean (f)
Distance and
- Mean (f)
- Mean (f)
Reported Measurement)
(LLD)
- Range Direction
- Range
- Range Measurements **
Aquatic Vegetation (pCi/kg wet)
Gamma (3)
No Control Be-7 K-40 Terrestrial Vegetation (pCi/kg wet)
Gamma (2) 1,086 (2/3)
(299 - 1,873) 3,047 (3/3)
(1,861 - 4,998) 1,424 (2/2)
(1,018 - 1,830) 6,667 (2/2)
(5,868 - 7,467)
DC-ALT 1.5 miles NW EEA 3.0 miles NNW 1,873(1/1) 4,998 (1/1) 0 0
No Control Be-7 K-40 MUDS 1.5 miles WNW EEA 3.0 miles NNW 1,830(1/1) 7,467 (1/1) 0 0
Soil (pCi/kg dry)
Gamma (3)
No Control K-40 10,441 (3/3)
(8,935 - 11,641) 191 (3/3)
(148-250)
MUDS 1.5 miles WNW EEA 3.0 miles NNW Cs-1 37 11,641 (1/1) 212 (2/2)
(174-250) 3,071 (1/1) 0 0
Deer (pCi/kg wet)
Gamma (1)
No Control K-40 3,071 (1/1) 251 (1/1)
R2.7 2.7 miles NNW R2.7 2.7 miles NNW 0
0 Tritium (1) 251 (1/1)
Page B-5
- Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (f)
Appendix C Individual Sample Results
Air Particulate and Charcoal Filters Location: 002 Collection Start Date 31-DEC-12 07-JAN-1 3 14-JAN-13 21-JAN-13 28-JAN-13 05-FEB-13 12-FEB-13 19-FEB-13 25-FEB-1 3 05-MAR-13 12-MAR-1 3 19-MAR-1 3 26-MAR-13 01-APR-13 01-APR-13 08-APR-13 15-APR-1 3 15-APR-13 22-APR-1 3 29-APR-13 06-MAY-1 3 06-MAY-13 13-MAY-1 3 20-MAY-13 28-MAY-1 3 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 19-AUG-13 26-AUG-13 Collection End Date 07-JAN-13 14-JAN-1 3 21-JAN-13 28-JAN-1 3 05-FEB-13 12-FEB-13 19-FEB-1 3 25-FEB-13 05-MAR-1 3 12-MAR-13 19-MAR-1 3 26-MAR-13 01-APR-13 08-APR-13 08-APR-13 15-APR-13 22-APR-1 3 22-APR-13 29-APR-1 3 06-MAY-1 3 13-MAY-13 13-MAY-1 3 20-MAY-13 28-MAY-1 3 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 19-AUG-13 26-AUG-13 03-SEP-13 Volume m
3 Gross Beta Concentration (pCi/m 3 )
1-131 Concentration (pCi/m 3)
Duplicate Analysis 313 293 297 295 355 280 301 258 338 302 295 308 247 294 294 300 309 309 301 310 294 294 290 349 262 288 304 301 293 296 301 298 306 297 303 297 300 339 0.037 0.032 0.029 0.037 0.036 0.031 0.024 0.025 0.038 0.024 0.020 0.023 0.022 0.026 0.016 0.016 0.017 0.022 0.025 0.018 0.018 0.028 0.009 0.015 0.020 0.023 0.026 0.023 0.021 0.025 0.015 0.018 0.026 0.025 0.025 0.036 0.023
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.004 0.005 0.004 0.005 0.004 0.005 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.013 0.019 0.012 0.008 0.013 0.010 0.011 0.011 0.009 0.012 0.017 0.013 0.017 0.017 0.006 0.007 0.009 0.007 0.014 0.014 0.013 0.013 0.011 0.013 0.010 0.015 0.011 0.012 0.010 0.011 0.010 0.008 0.012 0.011 0.014 Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 1
Air Particulate and Charcoal Filters Location: 002 Collection Start Date 03-SEP-1 3 09-SEP-13 17-SEP-13 23-SEP-13 30-SEP-1 3 07-OCT-13 14-OCT-1 3 21-OCT-13 29-OCT-1 3 04-NOV-13 11-NOV-13 18-NOV-13 25-NOV-13 02-DEC-1 3 09-DEC-13 16-DEC-13 23-DEC-1 3 30-DEC-13 Collection End Date 09-SEP-13 17-SEP-1 3 23-SEP-13 30-SEP-13 07-OCT-13 14-OCT-13 21-OCT-1 3 29-OCT-1 3 04-NOV-1 3 11-NOV-13 18-NOV-13 25-NOV-13 02-DEC-13 09-DEC-1 3 16-DEC-13 23-DEC-1 3 30-DEC-1 3 07-JAN-14 Volume Gross Beta m3 Concentration (pCi/m 3 )
1-131 Concentration (pCi/m 3)
Duplicate Analysis 261 349 255 294 301 299 300 337 260 299 306 311 302 306 289 308 299 353 0.039 0.029 0.027 0.032 0.017 0.022 0.016 0.020 0.019 0.019 0.025 0.024 0.033 0.038 0.045 0.036 0.036
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.005 0.004 0.005 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.005 0.005 0.005
< 0.017
< 0.012
< 0.010
< 0.014
< 0.007
< 0.020
< 0.015
< 0.007
< 0.011
< 0.011
< 0.009
< 0.010
< 0.013
< 0.018
< 0.011
< 0.015
< 0.012
< 0.008 0.031 +/- 0.004 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 2
Air Particulate and Charcoal Filters Location: 018 Collection Start Date 31-DEC-1 2 07-JAN-13 14-JAN-1 3 21-JAN-13 28-JAN-13 05-FEB-13 12-FEB-1 3 19-FEB-1 3 25-FEB-13 05-MAR-1 3 05-MAR-13 12-MAR-13 19-MAR-1 3 26-MAR-13 01-APR-13 01-APR-13 01-APR-13 08-APR-13 15-APR-13 22-APR-13 29-APR-13 06-MAY-1 3 13-MAY-13 13-MAY-13 20-MAY-1 3 28-MAY-13 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 19-AUG-13 Collection End Date 07-JAN-13 14-JAN-1 3 21-JAN-13 28-JAN-13 05-FEB-1 3 12-FEB-13 19-FEB-1 3 25-FEB-13 05-MAR-1 3 12-MAR-13 12-MAR-13 19-MAR-1 3 26-MAR-13 01-APR-13 08-APR-13 08-APR-1 3 08-APR-13 15-APR-13 22-APR-1 3 29-APR-13 06-MAY-13 13-MAY-1 3 20-MAY-13 20-MAY-13 28-MAY-13 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 19-AUG-13 26-AUG-13 Volume m
3 Gross Beta Concentration (pCi/m 3 )
1-131 Concentration (pCi/m 3)
Duplicate Analysis 315 299 297 302 349 302 304 257 340 299 299 300 311 248 293 293 293 300 314 299 311 294 298 298 360 254 295 310 303 299 302 300 293 303 298 298 298 306 0.046 0.037 0.029 0.041 0.036 0.032 0.024 0.027 0.036 0.026 0.023 0.028 0.021 0.025 0.023 0.021 0.018 0.018 0.020 0.018 0.023 0.025 0.030 0.013 0.014 0.020 0.021 0.025 0.022 0.026 0.021 0.017 0.023 0.026 0.023 0.026 0.034
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-4/-
+1-
+1-
+1-
+1-4/-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-4/-
+1-
+1-4/-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.005 0.005 0.004 0.005 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.013 0.019 0.012 0.008 0.014 0.009 0.011 0.011 0.009 0.012 0.017 0.013 0.017 0.017 0.006 0.007 0.009 0.007 0.014 0.014 0.013 0.013 0.011 0.013 0.010 0.015 0.011 0.012 0.010 0.011 0.010 0.008 0.012 0.010 Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 3
Air Particulate and Charcoal Filters Location: 018 Collection Start Date 26-AUG-13 03-SEP-13 09-SEP-13 17-SEP-13 23-SEP-1 3 30-SEP-13 07-OCT-1 3 14-OCT-1 3 21-OCT-13 29-OCT-1 3 04-NOV-13 11-NOV-13 18-NOV-13 25-NOV-13 02-DEC-13 09-DEC-1 3 16-DEC-1 3 23-DEC-13 30-DEC-1 3 Collection End Date 03-SEP-13 09-SEP-1 3 17-SEP-13 23-SEP-13 30-SEP-13 07-OCT-1 3 14-OCT-13 21-OCT-13 29-OCT-1 3 04-NOV-13 11-NOV-13 18-NOV-13 25-NOV-1 3 02-DEC-1 3 09-DEC-13 16-DEC-1 3 23-DEC-1 3 30-DEC-13 07-JAN-1 4 Volume m 3 Gross Beta Concentration (pCi/m 3 )
1-131 Concentration (pCilm 3)
Duplicate Analysis 337 263 349 254 303 297 302 302 342 260 307 312 318 305 315 296 308 294 351 0.024 0.041 0.028 0.029 0.033 0.016 0.024 0.016 0.024 0.023 0.018 0.024 0.025 0.035 0.037 0.047 0.037 0.037 0.036
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.004 0.005 0.004 0.005 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.005 0.005 0.005 0.004 0.014 0.017 0.012 0.010 0.014 0.007 0.020 0.015 0.007 0.011 0.011 0.009 0.009 0.013 0.017 0.011 0.015 0.013 0.008 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 4
Air Particulate and Charcoal Filters Location: 032 Collection Start Date 31-DEC-1 2 07-JAN-1 3 14-JAN-1 3 21-JAN-13 28-JAN-1 3 05-FEB-1 3 12-FEB-13 19-FEB-1 3 25-FEB-13 05-MAR-13 12-MAR-1 3 19-MAR-13 26-MAR-1 3 26-MAR-13 01-APR-13 01 -APR-13 08-APR-13 15-APR-1 3 22-APR-13 29-APR-13 06-MAY-1 3 13-MAY-13 20-MAY-1 3 28-MAY-13 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 19-AUG-13 26-AUG-13 03-SEP-1 3 Collection End Date 07-JAN-13 14-JAN-1 3 21-JAN-13 28-JAN-1 3 05-FEB-13 12-FEB-1 3 19-FEB-13 25-FEB-13 05-MAR-1 3 12-MAR-13 19-MAR-1 3 26-MAR-1 3 01 -APR-13 01-APR-13 08-APR-1 3 08-APR-13 15-APR-1 3 22-APR-13 29-APR-13 06-MAY-13 13-MAY-1 3 20-MAY-13 28-MAY-1 3 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 27-JUN-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 19-AUG-13 26-AUG-13 03-SEP-13 09-SEP-13 Volume m 3 Gross Beta Concentration (pCi/m 3 )
1-131 Concentration (pCi/m 3)
Duplicate Analysis 318 296 297 307 347 304 302 254 343 302 300 309 248 248 299 299 304 311 301 306 295 304 344 260 294 305 304 140 289 298 296 303 298 302 297 300 335 264 0.046 0.034 0.024 0.036 0.035 0.030 0.023 0.029 0.036 0.023 0.028 0.022 0.025 0.022 0.023 0.017 0.016 0.024 0.014 0.022 0.026 0.012 0.013 0.020 0.019 0.026 0.025 0.024 0.023 0.018 0.022 0.029 0.020 0.026 0.041 0.025 0.038
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
.1-I-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.005 0.005 0.004 0.005 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.009 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.005 0.013 0.019 0.012 0.008 0.014 0.009 0.011 0.011 0.009 0.012 0.017 0.013 0.017 Duplicate
< 0.017 0.006 0.007 0.009 0.007 0.014 0.013 0.013 0.013 0.011 0.013 0.010 0.037 0.011 0.012 0.010 0.011 0.010 0.008 0.012 0.011 0.015 0.017 2013 Annual Radiological Environmental Wolf Creek Generating Station Operating Report Page C - 5
Air Particulate and Charcoal Filters Location: 032 Collection Start Date 09-SEP-1 3 17-SEP-1 3 23-SEP-13 30-SEP-1 3 07-OCT-1 3 14-OCT-1 3 21-OCT-13 29-OCT-1 3 04-NOV-13 11-NOV-13 18-NOV-13 25-NOV-1 3 25-NOV-13 02-DEC-13 09-DEC-1 3 16-DEC-1 3 23-DEC-1 3 30-DEC-1 3 Collection End Date 17-SEP-13 23-SEP-13 30-SEP-13 07-OCT-1 3 14-OCT-1 3 21-OCT-1 3 29-OCT-13 04-NOV-1 3 11-NOV-13 18-NOV-13 25-NOV-1 3 02-DEC-1 3 02-DEC-13 09-DEC-1 3 16-DEC-13 23-DEC-1 3 30-DEC-13 07-JAN-14 Volume m 3 Gross Beta Concentration (pCi/r 3 )
1-131 Concentration (pCi/m 3)
Duplicate Analysis 337 256 296 299 300 301 341 258 311 304 314 308 308 305 289 307 289 341 0.026 0.025 0.036 0.018 0.023 0.019 0.021 0.026 0.018 0.025 0.022 0.036 0.037 0.039 0.045 0.040 0.035 0.032
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.004 0.005 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.005 0.005 0.005 0.005 0.004 0.012 0.010 0.014 0.007 0.020 0.015 0.007 0.011 0.011 0.009 0.010 0.012 0.018 0.011 0.015 0.013 0.008 Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 6
Air Particulate and Charcoal Filters Location: 037 Collection Start Date 31-DEC-12 07-JAN-1 3 14-JAN-13 21-JAN-13 21-JAN-1 3 28-JAN-13 05-FEB-13 05-FEB-13 12-FEB-13 19-FEB-13 25-FEB-1 3 05-MAR-13 12-MAR-1 3 12-MAR-13 19-MAR-1 3 19-MAR-13 26-MAR-1 3 01-APR-13 01-APR-13 08-APR-13 15-APR-13 22-APR-13 29-APR-1 3 29-APR-13 06-MAY-13 13-MAY-1 3 20-MAY-13 28-MAY-1 3 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 Collection End Date 07-JAN-1 3 14-JAN-13 21-JAN-1 3 28-JAN-1 3 28-JAN-1 3 05-FEB-1 3 12-FEB-13 12-FEB-1 3 19-FEB-13 25-FEB-13 05-MAR-13 12-MAR-1 3 19-MAR-13 19-MAR-1 3 26-MAR-13 26-MAR-1 3 01-APR-13 08-APR-1 3 08-APR-13 15-APR-13 22-APR-13 29-APR-1 3 06-MAY-1 3 06-MAY-13 13-MAY-1 3 20-MAY-13 28-MAY-1 3 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 Volume m 3 Gross Beta Concentration (pCi/m 3 )
1-131 Concentration (pCi/m 3)
Duplicate Analysis 321 297 296 301 301 360 303 303 301 260 345 300 299 299 313 313 249 295 295 305 311 304 309 309 296 300 347 257 293 303 302 288 301 299 300 307 299 285 0.045 0.034 0.025 0.037 0.039 0.034 0.033 0.031 0.023 0.026 0.034 0.024 0.026 0.027 0.022 0.021 0.023 0.021 0.017 0.015 0.020 0.017 0.015 0.022 0.029 0.011 0.014 0.018 0.019 0.026 0.027 0.025 0.023 0.018 0.018 0.023 0.028
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.005 0.005 0.004 0.005 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.005 0.013 0.019 0.012 0.008 0.013 0.009 0.011 0.010 0.009 0.012 0.017 0.013 0.017 0.017 0.006 0.007 0.009 0.007 0.014 0.013 0.013 0.013 0.011 0.013 0.010 0.015 0.011 0.012 0.010 0.011 0.010 0.009 Duplicate Duplicate Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 7
Air Particulate and Charcoal Filters Location: 037 Collection Start Date 12-AUG-13 19-AUG-13 26-AUG-13 26-AUG-13 03-SEP-13 09-SEP-13 17-SEP-13 23-SEP-1 3 30-SEP-13 07-OCT-1 3 14-OCT-1 3 21-OCT-13 29-OCT-1 3 04-NOV-13 11 -NOV-13 18-NOV-13 25-NOV-1 3 02-DEC-13 09-DEC-1 3 16-DEC-13 23-DEC-1 3 30-DEC-13 Collection End Date 19-AUG-13 26-AUG-1 3 03-SEP-1 3 03-SEP-13 09-SEP-1 3 17-SEP-13 23-SEP-1 3 30-SEP-13 07-OCT-1 3 14-OCT-13 21-OCT-13 29-OCT-13 04-NOV-1 3 11-NOV-13 18-NOV-13 25-NOV-1 3 02-DEC-1 3 09-DEC-13 16-DEC-1 3 23-DEC-13 30-DEC-1 3 07-JAN-14 Volume Gross Beta m 3 Concentration (pCilm3 )
1-131 Concentration (pCi/m 3)
Duplicate Analysis 300 300 341 341 264 338 255 297 301 297 303 340 261 301 308 320 306 315 289 309 289 353 0.024 0.041 0.021 0.026 0.043 0.027 0.025 0.033 0.017 0.023 0.018 0.022 0.023 0.020 0.022 0.024 0.034 0.045 0.049 0.037 0.035 0.031
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.004 0.005 0.004 0.004 0.005 0.004 0.005 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.005 0.005 0.005 0.004
< 0.012
< 0.011
< 0.014 Duplicate 0.017 0.012 0.010 0.014 0.007 0.020 0.015 0.007 0.011 0.011 0.009 0.009 0.012 0.017 0.011 0.015 0.013 0.008 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 8
Air Particulate and Charcoal Filters Location: 049 Collection Start Date 31-DEC-12 07-JAN-1 3 14-JAN-13 21-JAN-13 28-JAN-1 3 05-FEB-1 3 12-FEB-13 19-FEB-1 3 25-FEB-13 05-MAR-1 3 12-MAR-1 3 19-MAR-13 26-MAR-1 3 01-APR-13 01-APR-13 08-APR-13 15-APR-1 3 22-APR-13 29-APR-1 3 06-MAY-13 13-MAY-1 3 20-MAY-13 28-MAY-1 3 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 19-AUG-13 26-AUG-13 03-SEP-13 09-SEP-13 Collection End Date 07-JAN-13 14-JAN-13 21-JAN-13 28-JAN-1 3 05-FEB-13 12-FEB-13 19-FEB-13 25-FEB-1 3 05-MAR-13 12-MAR-1 3 19-MAR-13 26-MAR-1 3 01-APR-13 08-APR-13 08-APR-1 3 15-APR-13 22-APR-1 3 29-APR-1 3 06-MAY-1 3 13-MAY-13 20-MAY-1 3 28-MAY-13 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 19-AUG-13 26-AUG-13 03-SEP-1 3 09-SEP-13 17-SEP-13 Volume m 3 Gross Beta Concentration (pCi/m 3 )
1-131 Concentration (pCi/m 3)
Duplicate Analysis 307 297 296 302 355 303 300 263 347 297 297 312 248 294 294 306 310 301 311 296 296 348 258 291 302 302 295 299 299 297 304 295 304 300 300 341 261 350 0.049 0.040 0.025 0.037 0.038 0.031 0.026 0.027 0.037 0.023 0.031 0.023 0.026 0.021 0.014 0.018 0.021 0.015 0.022 0.026 0.013 0.014 0.017 0.023 0.029 0.023 0.021 0.023 0.016 0.021 0.026 0.024 0.024 0.040 0.025 0.040 0.029
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.005 0.005 0.004 0.005 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.003 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.005 0.004 0.013 0.019 0.012 0.008 0.013 0.009 0.011 0.010 0.009 0.012 0.017 0.013 0.017 0.017 0.006 0.007 0.009 0.007 0.014 0.014 0.013 0.013 0.011 0.013 0.010 0.015 0.011 0.012 0.010 0.011 0.010 0.008 0.012 0.011 0.014 0.017 0.012 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 9
Air Particulate and Charcoal Filters Location: 049 Collection Start Date 09-SEP-13 17-SEP-13 23-SEP-13 30-SEP-1 3 07-OCT-13 14-OCT-1 3 21-OCT-13 29-OCT-1 3 29-OCT-1 3 04-NOV-1 3 11-NOV-13 18-NOV-13 25-NOV-1 3 02-DEC-1 3 09-DEC-13 16-DEC-1 3 23-DEC-13 30-DEC-13 Collection End Date 17-SEP-13 23-SEP-13 30-SEP-13 07-OCT-13 14-OCT-1 3 21-OCT-13 29-OCT-1 3 04-NOV-13 04-NOV-1 3 11-NOV-13 18-NOV-13 25-NOV-1 3 02-DEC-13 09-DEC-13 16-DEC-13 23-DEC-13 30-DEC-1 3 07-JAN-14 Volume Gross Beta m 3 Concentration (pCiIm3 )
1-131 Concentration (pCi/m 3) 350 256 300 300 299 303 343 261 261 329 309 314 309 311 290 309 291 353 0.026 0.026 0.031 0.015 0.022 0.019 0.022 0.024 0.025 0.018 0.027 0.022 0.036 0.042 0.050 0.041 0.037 0.031
-'-I-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.004 0.005 0.005 0.004 0.004 0.004 0.004 0.005 0.005 0.004 0.004 0.004 0.004 0.005 0.005 0.005 0.005 0.004 0.010 0.014 0.007 0.020 0.015 0.007 0.011 0.010 0.009 0.010 0.012 0.018 0.011 0.015 0.013 0.008 Duplicate Analysis Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 10
Air Particulate and Charcoal Filters Location: 053 Collection Start Date 31 -DEC-1 2 07-JAN-13 14-JAN-1 3 14-JAN-13 21-JAN-1 3 28-JAN-13 05-FEB-13 12-FEB-1 3 19-FEB-13 25-FEB-1 3 05-MAR-13 12-MAR-13 19-MAR-13 26-MAR-1 3 01-APR-13 01-APR-13 08-APR-13 15-APR-1 3 22-APR-13 29-APR-1 3 06-MAY-13 13-MAY-1 3 20-MAY-13 20-MAY-1 3 28-MAY-13 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 19-AUG-13 26-AUG-13 Collection End Date 07-JAN-1 3 14-JAN-13 21-JAN-13 21-JAN-13 28-JAN-1 3 05-FEB-13 12-FEB-13 19-FEB-13 25-FEB-13 05-MAR-13 12-MAR-1 3 19-MAR-13 26-MAR-1 3 01-APR-13 08-APR-1 3 08-APR-13 15-APR-13 22-APR-1 3 29-APR-1 3 06-MAY-13 13-MAY-1 3 20-MAY-13 28-MAY-1 3 28-MAY-1 3 03-JUN-13 10-JUN-13 17-JUN-13 24-JUN-13 01-JUL-13 08-JUL-13 15-JUL-13 22-JUL-13 29-JUL-13 05-AUG-13 12-AUG-13 19-AUG-13 26-AUG-13 03-SEP-1 3 Volume Gross Beta m3 Concentration (pCilm3 )
1-131 Concentration (pCi/m 3)
Duplicate Analysis 304 298 297 297 298 351 299 300 258 334 296 294 313 247 293 293 305 313 299 308 261 292 351 351 255 293 304 304 295 296 297 294 303 299 299 298 305 335 0.052 0.036 0.025 0.032 0.038 0.034 0.029 0.026 0.027 0.032 0.019 0.028 0.024 0.020 0.024 0.017 0.014 0.021 0.015 0.020 0.024 0.011 0.012 0.014 0.017 0.020 0.024 0.021 0.020 0.021 0.016 0.023 0.029 0.021 0.025 0.041 0.023
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.005 0.005 0.004 0.005 0.005 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.003 0.003 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.004
< 0.013
< 0.019 Duplicate 0.012 0.008 0.014 0.009 0.011 0.011 0.009 0.012 0.017 0.013 0.017 0.017 0.006 0.007 0.009 0.007 0.016 0.014 0.013 0.013 0.011 0.013 0.010 0.015 0.011 0.012 0.010 0.011 0.010 0.008 0.012 0.010 0.015 Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 11
Air Particulate and Charcoal Filters Location: 053 Collection Start Date 03-SEP-13 09-SEP-13 17-SEP-1 3 23-SEP-1 3 30-SEP-13 07-OCT-13 14-OCT-13 21-OCT-13 29-OCT-1 3 04-NOV-1 3 11-NOV-13 18-NOV-13 25-NOV-13 02-DEC-13 09-DEC-13 16-DEC-1 3 23-DEC-1 3 30-DEC-13 Collection End Date 09-SEP-13 17-SEP-13 23-SEP-13 30-SEP-13 07-OCT-1 3 14-OCT-1 3 21-OCT-13 29-OCT-1 3 04-NOV-1 3 11-NOV-13 18-NOV-13 25-NOV-13 02-DEC-13 09-DEC-13 16-DEC-13 23-DEC-13 30-DEC-1 3 07-JAN-14 Volume m
3 Gross Beta Concentration (pCi/m 3 )
1-131 Concentration (pCilm 3)
Duplicate Analysis 261 338 261 302 295 300 301 339 263 312 304 314 306 306 290 308 293 347 0.036 0.026 0.029 0.029 0.016 0.022 0.017 0.021 0.019 0.017 0.025 0.025 0.033 0.040 0.044 0.038 0.030 0.033
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-
+1-0.005 0.004 0.005 0.004 0.004 0.004 0.004 0.004 0.005 0.004 0.004 0.004 0.004 0.005 0.005 0.005 0.004 0.004 0.017 0.012 0.010 0.014 0.007 0.020 0.015 0.007 0.010 0.011 0.009 0.010 0.012 0.018 0.011 0.015 0.013 0.008 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 12
Quarterly Air Particulate - Gamma Location:
002 01-APR-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 01-JUL-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 30-SEP-1 3 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 Concentration (pCi/m 3 )
0.064+/-
0.011 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCilm3 )
0.092+/-
0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )
0.080+/-
0.017 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 13
Quarterly Air Particulate - Gamma Location:
002 30-DEC-1 3 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 Concentration (pCi/lm 3 )
0.052+/-
0.012 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 14
Quarterly Air Particulate - Gamma Location:
018 01 -APR-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 01-JUL-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 30-SEP-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 Concentration (pCilm 3 )
0.079+/-
0.013 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCilm3 )
0.079+/-
0.014 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )
0.070+/-
0.013 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 15
Quarterly Air Particulate - Gamma Location:
018 30-DEC-1 3 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 Concentration (DCilm 3 )
0.065+/-
0.013 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-16
Quarterly Air Particulate - Gamma Location:
032 01-APR-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 01-JUL-13 Nuclide BE-7 MN-54 C0-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 30-SEP-1 3 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 Concentration (pCi/m 3 )
0.080+/-
0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCilm3 )
0.084+/-
0.015 0.001 0.001 0.002 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )
0.088+/-
0.016 0.001 0.001 0.002 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 17
Quarterly Air Particulate - Gamma Location:
032 30-DEC-1 3 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 Concentration (pCilm 3 )
0.070+/-
0.014 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 18
Quarterly Air Particulate - Gamma Location:
037 01-APR-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 01-JUL-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 30-SEP-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 Concentration (pCiIm 3 )
0.075+/-
0.014 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )
0.083+/-
0.010 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCilm 3 )
0.074+/-
0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 19
Quarterly Air Particulate - Gamma Location:
037 30-DEC-1 3 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 Concentration (pCi/m 3 )
0.069+/-
0.016 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-20
Quarterly Air Particulate - Gamma Location:
049 01-APR-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 01-JUL-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 30-SEP-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 Concentration (pCilm3 )
0.080+/-
0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCiIm3 )
0.088+/-
0.013 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )
0.083+/-
0.014 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 21
Quarterly Air Particulate - Gamma Location:
049 30-DEC-1 3 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 Concentration (pCilm3 )
0.063+/-
0.013 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-22
Quarterly Air Particulate - Gamma Location:
053 01-APR-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 01-JUL-13 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 30-SEP-1 3 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-i 34 CS-1 37 Concentration (pCilm3 )
0.073+/-
0.012 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 Concentration (pCi/m 3 )
0.087+/-
0.013 0.001 0.001 0.001 0.001 0.002 0.001 0.001 0.001 Concentration (pCiIm3 )
0.081+/-
0.013 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-23
Quarterly Air Particulate - Gamma Location:
053 30-DEC-1 3 Nuclide BE-7 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 Concentration (pCilm3 )
0.063+/-
0.015 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001
- Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-24
Exposure Pathway - Waterborne Surface Water Location JRR Collection Date 14-JAN-13 14-JAN-13 14-JAN-1 3 14-JAN-13 14-JAN-13 14-JAN-1 3 14-JAN-13 14-JAN-13 14-JAN-1 3 14-JAN-13 14-JAN-1 3 19-FEB-13 19-FEB-13 19-FEB-13 19-FEB-13 19-FEB-1 3 19-FEB-13 19-FEB-13 19-FEB-13 19-FEB-13 19-FEB-13 19-FEB-1 3 19-FEB-13 14-MAR-13 14-MAR-1 3 14-MAR-1 3 14-MAR-13 14-MAR-13 14-MAR-1 3 14-MAR-13 14-MAR-13 14-MAR-1 3 14-MAR-13 14-MAR-13 14-MAR-1 3 14-MAR-13 14-MAR-1 3 14-MAR-1 3 14-MAR-13 Nuclide MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 1-131 1-131 CS-134 CS-134 Concentration (pCi/Liter) 3.5 2.9 4.1 3.3 5.9 5.3 7.5 4.0 4.8 4.6 138.0 3.7 3.9 4.1 4.9 6.8 1.9 3.7 3.0 4.8 5.3 143.0 157.8 4.9 2.6 5.6 1.6 8.7 7.0 1.8 2.8 4.9 3.4 4.0 3.5 6.0 3.6 4.9 2.8 Duplicate Analysis Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 25
Exposure Pathway - Waterborne Surface Water Location JRR Collection Date 14-MAR-13 14-MAR-13 14-MAR-13 14-MAR-13 14-MAR-13 14-MAR-1 3 16-APR-13 16-APR-13 16-APR-13 16-APR-13 16-APR-13 16-APR-13 16-APR-13 16-APR-13 16-APR-13 16-APR-13 16-APR-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 Nuclide Concentration (pCilLiter)
CS-137 CS-137 BA-LA-140 BA-LA-140 H-3 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-137 BA-LA-140 2.7 3.6 6.9 3.6 145.0 145.0 2.6 2.6 4.7 2.2 5.6 1.7 5.4 3.0 2.8 2.3 145.0 2.0 1.9 3.6 2.4 3.0 3.0 7.8 2.9 2.9 1.9 145.0 150.3 3.3 2.4 2.6 2.5 2.4 2.6 5.5 2.7 3.5 2.6 Duplicate Analysis Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 26
Exposure Pathway - Waterborne Surface Water Location JRR Collection Date 11-JUN-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 23-SEP-13 23-SEP-1 3 23-SEP-13 23-SEP-13 23-SEP-1 3 23-SEP-13 23-SEP-13 23-SEP-13 23-SEP-13 23-SEP-1 3 23-SEP-13 21-OCT-13 21-OCT-1 3 21-OCT-13 21-OCT-13 Nuclide H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 Concentration (pCi/Liter)
Duplicate Analysis 142.0 5.7 3.4 7.9 5.0 6.1 4.7 8.5 5.2 3.8 3.5 159.0 2.4 1.7 6.2 4.3 2.0 3.8 6.9 3.7 3.5 3.1 149.0 148.6 1.5 1.8 5.4 0.9 4.3 2.8 4.0 2.9 3.3 1.4 146.0 6.2 3.5 2.7 4.1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-27
Exposure Pathway - Waterborne Surface Water Location JRR Collection Date 21-OCT-13 21-OCT-13 21-OCT-13 21-OCT-13 21-OCT-13 21-OCT-13 21-OCT-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 16-DEC-1 3 16-DEC-13 16-DEC-1 3 16-DEC-1 3 16-DEC-13 16-DEC-13 16-DEC-13 16-DEC-13 16-DEC-13 16-DEC-13 16-DEC-1 3 Nuclide ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 Concentration (pCi/Liter)
Duplicate Analysis 4.1 5.2 6.8 5.6 5.6 3.6 148.0 4.3 1.9 3.5 2.5 6.5 5.0 6.6 4.3 4.8 2.0 149.0 157.3 1.8 2.5 5.2 1.4 3.3 3.1 2.8 2.9 3.2 2.5 145.0 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-28
Exposure Pathway - Waterborne Surface Water Location SP Collection Date 14-JAN-13 14-JAN-13 14-JAN-1 3 14-JAN-1 3 14-JAN-13 14-JAN-1 3 14-JAN-13 14-JAN-1 3 14-JAN-13 14-JAN-1 3 14-JAN-1 3 19-FEB-13 19-FEB-1 3 19-FEB-1 3 19-FEB-13 19-FEB-13 19-FEB-1 3 19-FEB-13 19-FEB-13 19-FEB-1 3 19-FEB-13 19-FEB-13 19-FEB-13 14-MAR-1 3 14-MAR-13 14-MAR-13 14-MAR-1 3 14-MAR-13 14-MAR-1 3 14-MAR-1 3 14-MAR-13 14-MAR-1 3 14-MAR-13 14-MAR-1 3 16-APR-13 16-APR-13 16-APR-13 16-APR-1 3 16-APR-13 Nuclide Concentration (pCi/Liter)
Duplicate Analysis MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 11,358+1 13,170+1 12,805+1 2.4 2.8 5.0 2.3 5.1 2.6 3.8 2.9 2.6 3.0 305.0 2.5 3.3 4.8 3.4 8.2 5.3 5.0 3.2 3.8 4.2 324.0 151.1 3.4 3.5 6.1 3.0 5.3 3.7 5.2 3.0 3.7 4.6 328.0 3.2 3.2 5.3 3.6 7.3 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-29
Exposure Pathway - Waterborne Surface Water Location SP Collection Date 16-APR-13 16-APR-1 3 16-APR-13 16-APR-13 16-APR-1 3 16-APR-1 3 20-MAY-13 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-13 20-MAY-13 20-MAY-1 3 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 15-JUL-13 Nuclide Concentration (pCi/Liter)
Duplicate Analysis ZR-NB-95 1-131 CS-1 34 CS-1 37 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BA-LA-140 12,354
+/-
11,536+1 11,175+1 5.5 7.9 2.5 4.2 5.2 320.0 2.4 1.9 4.3 1.6 2.6 3.1 6.4 2.8 2.0 5.3 306.0 151.2 4.8 2.3 6.3 4.1 3.9 3.9 9.3 4.3 5.0 4.9 305.0 2.8 3.6 5.0 2.9 6.9 4.3 5.6 3.8 4.1 4.8 2013 Annual Radiological Envi Wolf Creek Generating Station ironmental Operating Report Page C - 30
Exposure Pathway - Waterborne Surface Water Location SP Collection Date 15-JUL-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-1 3 26-AUG-13 26-AUG-1 3 23-SEP-13 23-SEP-13 23-SEP-13 23-SEP-13 23-SEP-13 23-SEP-13 23-SEP-13 23-SEP-13 23-SEP-1 3 23-SEP-13 23-SEP-13 21-OCT-13 21-OCT-13 21-OCT-13 21-OCT-13 21-OCT-13 21 -OCT-1 3 21 -OCT-1 3 21-OCT-13 21-OCT-13 21-OCT-1 3 21-OCT-13 18-NOV-13 18-NOV-1 3 18-NOV-13 18-NOV-13 Nuclide Concentration (pCi/Liter)
Duplicate Analysis H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 MN-54 CO-58 FE-59 CO-60 10,867
+/-
9,295+1 9,340+-
9,970+1 309.0 5.5 2.7 9.2 3.3 6.0 5.3 4.9 3.7 5.0 4.8 280.0 153.9 1.3 1.6 3.2 1.8 2.2 1.6 3.8 1.7 3.3 2.8 282.0 6.0 2.3 5.0 2.1 8.8 7.3 4.4 5.7 6.3 5.5 293.0 3.0 1.5 4.3 2.2 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 31
Exposure Pathway - Waterborne Surface Water Location SP Collection Date 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 16-DEC-13 16-DEC-1 3 16-DEC-13 16-DEC-13 16-DEC-13 16-DEC-13 16-DEC-1 3 16-DEC-13 16-DEC-1 3 16-DEC-1 3 16-DEC-13 Nuclide Concentration (pCi/Liter)
Duplicate Analysis ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BA-LA-140 H-3 FE-55 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BA-LA-140 H-3 11,024
+1 10,309+1 6.2 2.6 5.2 3.4 3.3 3.2 309.0 155.4 2.6 2.1 4.6 1.5 2.2 2.1 4.0 2.4 2.7 1.1 296.0 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-32
Exposure Pathway - Waterborne Ground Water Location B-12 Collection Date 08-MAR-1 3 08-MAR-13 08-MAR-13 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-13 08-MAR-13 08-MAR-13 08-MAR-1 3 08-MAR-13 20-MAY-1 3 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-1 3 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 Nuclide MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 Concentration (pCi/Liter)
Duplicate Analysis 2.6 2.3 4.2 3.1 3.9 2.8 2.4 3.4 1.6 141.0 0.291 4.1 3.2 7.5 2.9 4.6 2.9 2.8 3.9 3.3 145.0 0.273 3.4 2.8 8.4 4.0 5.9 4.0 3.0 3.9 3.4 149.0 0.224 4.9 5.2 7.0 6.2 7.9 5.2 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-33
Exposure Pathway - Waterborne Ground Water Location B-12 Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 CS-1 34 CS-137 BA-LA-140 H-3 1-131 (CHEM) 5.8 4.3 2.4 149.0 0.441 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-34
Exposure Pathway - Waterborne Ground Water Location C-10 Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 08-MAR-13 08-MAR-13 08-MAR-13 08-MAR-1 3 08-MAR-13 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-1 3 20-MAY-1 3 26-AUG-1 3 26-AUG-13 26-AUG-1 3 26-AUG-1 3 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 25-NOV-13 25-NOV-13 25-NOV-13 25-NOV-13 25-NOV-1 3 25-NOV-1 3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 3.6 3.3 4.4 2.6 5.3 3.3 2.9 3.2 3.3 141.0 0.283 2.5 2.7 3.2 2.5 3.0 3.2 2.8 3.6 6.1 145.0 0.249 3.4 2.3 5.6 2.9 5.7 5.0 3.1 2.4 2.7 149.0 0.236 4.0 2.5 3.8 3.2 3.5 4.2 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-35
Exposure Pathway - Waterborne Ground Water Location C-10 Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 25-NOV-1 3 25-NOV-13 25-NOV-13 25-NOV-13 25-NOV-1 3 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM) 4.1 2.2 3.2 155.0 0.376 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-36
Exposure Pathway - Waterborne Ground Water Location C-49 Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-1 3 08-MAR-1 3 08-MAR-1 3 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 2.6 2.4 4.4 2.7 4.1 2.9 3.2 3.3 2.3 140.0 0.399 2.2 2.8 6.3 2.3 6.4 4.2 3.2 3.7 4.0 145.0 0.496 3.1 1.9 4.6 2.0 2.2 2.5 2.3 3.5 2.5 149.0 0.259 5.0 3.3 4.7 5.5 11.2 4.3 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-37
Exposure Pathway - Waterborne Ground Water Location C-49 Collection Date Nuclide Concentration (pCilLiter)
Duplicate Analysis 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM) 6.3 4.9 2.8 149.0 0.292 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -
38
Exposure Pathway - Waterborne Ground Water Location F-1 Collection Date 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-13 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 Nuclide Concentration (pCilLiter)
Duplicate Analysis MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)
MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 CS-134 CS-134 CS-137 CS-1 37 BA-LA-140 2.9 1.7 4.6 2.6 4.1 2.9 2.9 2.9 2.3 141.0 0.403 1.8 1.4 3.4 2.0 2.9 1.8 2.5 2.4 4.0 145.0 0.281 3.2 3.7 3.2 1.7 6.8 3.8 1.5 2.5 5.6 3.2 4.5 1.9 3.7 4.7 4.0 3.6 1.3 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-39
Exposure Pathway - Waterborne Ground Water Location F-I Collection Date 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 Nuclide Concentration (pCilLiter)
Duplicate Analysis BA-LA-140 H-3 H-3 1-131 (CHEM) 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 BA-LA-140 H-3 1-131 (CHEM) 3.1 149.0 149.0 0.319 0.303 2.3 2.9 4.2 2.8 4.2 3.6 3.2 2.7 4.2 149.0 0.459 Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -
40
Exposure Pathway - Waterborne Ground Water Location G-2 Collection Date 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-13 08-MAR-1 3 08-MAR-13 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 Nuclide MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 Concentration (pCi/Liter)
Duplicate Analysis 3.3 3.2 6.5 3.5 7.8 2.9 3.1 2.3 4.2 141.0 0.608 2.9 2.8 4.3 2.3 5.6 4.7 3.9 3.0 3.9 145.0 0.298 2.7 3.5 7.4 2.7 6.3 3.9 3.1 2.9 2.3 149.0 0.218 4.6 2.4 1.9 5.2 4.7 4.3 Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-41
Exposure Pathway - Waterborne Ground Water Location G-2 Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 CS-1 34 CS-134 CS-137 CS-1 37 BA-LA-140 BA-LA-140 H-3 H-3 1-131 (CHEM) 1-131 (CHEM) 5.9 1.7 5.8 4.2 3.0 3.0 2.6 5.6 2.4 4.2 3.2 2.2 149.0 149.0 0.456 0.233 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-42
Exposure Pathway - Waterborne Ground Water Location J-1 Collection Date 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-13 20-MAY-13 26-AUG-1 3 26-AUG-1 3 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-1 3 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-1 3 18-NOV-13 18-NOV-13 Nuclide MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 Concentration (pCilLiter)
Duplicate Analysis 3.1 2.8 4.9 3.3 6.8 4.5 2.4 2.9 3.1 141.0 0.364 3.2 1.7 2.1 1.8 3.7 2.5 3.2 3.4 2.8 145.0 0.286 2.1 2.2 2.9 2.3 5.7 2.3 2.5 2.7 1.9 149.0 0.236 3.2 3.2 4.9 3.1 6.1 3.9 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-43
Exposure Pathway - Waterborne Ground Water Location J-1 Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM) 3.5 3.1 2.0 149.0 0.262 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -
44
Exposure Pathway - Waterborne Ground Water Location J-2 Collection Date 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-13 08-MAR-1 3 08-MAR-1 3 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-13 20-MAY-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 25-NOV-13 25-NOV-13 25-NOV-13 25-NOV-13 25-NOV-13 25-NOV-13 Nuclide Concentration (pCilLiter)
Duplicate Analysis MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 3.4 1.9 3.9 2.6 5.8 3.2 2.9 4.1 5.9 141.0 0.399 2.7 3.2 3.6 1.8 3.9 3.4 3.1 2.8 4.9 145.0 0.347 3.2 2.7 4.0 2.2 4.6 3.4 2.4 2.9 2.8 149.0 0.21 3.2 1.6 5.2 2.7 4.1 3.1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-45
Exposure Pathway - Waterborne Ground Water Location J-2 Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 25-NOV-13 25-NOV-13 25-NOV-1 3 25-NOV-1 3 25-NOV-13 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM) 4.1 2.3 3.4 155.0 0.369 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-46
Exposure Pathway - Waterborne Ground Water Location L-49 Collection Date 08-MAR-13 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-13 08-MAR-13 08-MAR-1 3 08-MAR-1 3 08-MAR-13 08-MAR-13 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-1 3 20-MAY-13 20-MAY-13 20-MAY-13 20-MAY-1 3 20-MAY-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-1 3 18-NOV-13 18-NOV-1 3 18-NOV-1 3 18-NOV-13 18-NOV-13 18-NOV-13 Nuclide MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 H-3 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 Concentration (pCi/Liter)
Duplicate Analysis 2.0 2.6 3.5 2.0 3.1 2.4 3.1 2.5 1.8 141.0 0.423 4.3 2.3 4.7 2.3 6.8 3.8 3.1 3.0 3.8 145.0 0.284 2.5 2.2 2.5 2.5 2.9 2.4 2.6 2.7 1.3 149.0 0.21 2.6 2.6 6.2 3.3 4.5 2.7 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-47
Exposure Pathway - Waterborne Ground Water Location L-49 Collection Date Nuclide Concentration (pCilLiter)
Duplicate Analysis 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 CS-134 CS-1 37 BA-LA-140 H-3 1-131 (CHEM) 3.8 2.7 2.1 149.0 0.267 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -
48
Exposure Pathway - Waterborne Drinking Water Location BW-15 Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 05-FEB-13 05-FEB-1 3 05-FEB-1 3 05-FEB-13 05-FEB-13 05-FEB-1 3 05-FEB-1 3 05-FEB-13 05-FEB-1 3 05-FEB-13 05-FEB-1 3 05-MAR-13 05-MAR-13 05-MAR-1 3 05-MAR-1 3 05-MAR-13 05-MAR-13 05-MAR-1 3 05-MAR-1 3 05-MAR-13 05-MAR-13 05-MAR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 06-MAY-1 3 06-MAY-13 06-MAY-13 06-MAY-13 06-MAY-1 3 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-1 37 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 2.8 3.0 6.9 3.5 3.7 4.4 2.9 4.7 3.9 0.53 0.376 4.5 5.5 11.5 3.302+/-
< 4.2
< 5.8
< 4.5 2.173+/-
3.181 +/-
4.4 6.0 6.8 0.639 0.282 2.0 2.5 4.5 2.5 3.7 2.6 2.4 2.3 1.7 0.532 0.293 2.1 2.7 1.6 1.9 1.7 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -
49
Exposure Pathway - Waterborne Drinking Water Location BW-15 Collection Date 06-MAY-1 3 06-MAY-13 06-MAY-13 06-MAY-1 3 06-MAY-1 3 06-MAY-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-1 3 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-1 3 03-JUN-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 05-AUG-13 05-AUG-13 05-AUG-13 05-AUG-13 05-AUG-1 3 05-AUG-13 05-AUG-13 05-AUG-13 05-AUG-13 05-AUG-13 Nuclide Concentration (pCilLiter)
Duplicate Analysis ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 GROSS BETA 3.167+/-
2.8 2.0 3.9 1.4 0.71 0.308 4.3 2.5 4.8 2.9 7.6 3.7
< 4.4 3.006 +/-
3.758 +/-
2.579 +/-
3.6 2.9 0.689 0.43 3.7 2.3 5.8 2.9 4.1 2.6 3.0 2.9 3.6 0.743 0.278 2.8 1.6 4.8 1.7 3.5 3.1 2.9 3.4 2.2 0.647 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-50
Exposure Pathway - Waterborne Drinking Water Location BW-1 5 Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 05-AUG-13 03-SEP-1 3 03-SEP-13 03-SEP-13 03-SEP-1 3 03-SEP-1 3 03-SEP-13 03-SEP-13 03-SEP-1 3 03-SEP-1 3 03-SEP-13 03-SEP-13 07-OCT-1 3 07-OCT-1 3 07-OCT-13 07-OCT-13 07-OCT-13 07-OCT-1 3 07-OCT-13 07-OCT-1 3 07-OCT-1 3 07-OCT-13 07-OCT-1 3 04-NOV-13 04-NOV-13 04-NOV-1 3 04-NOV-1 3 04-NOV-1 3 04-NOV-13 04-NOV-13 04-NOV-1 3 04-NOV-13 04-NOV-13 04-NOV-13 05-DEC-13 05-DEC-1 3 05-DEC-13 05-DEC-13 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-1 40 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-1 34 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 3.997 +/-
3.152 +/-
2.724 +/-
0.189 1.9 3.0 3.4 1.4 2.1 1.9 2.4 2.9 1.2 0.746 0.288 3.9 3.3 5.6 1.0 6.5 3.0 2.9 2.3 1.3 0.691 0.353 3.8 3.1 7.2 3.6 8.3 4.0 5.0 4.5 5.6 0.492 0.262 4.0 3.5 5.4 2.1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-51
Exposure Pathway - Waterborne Drinking Water Location BW-15 Collection Date 05-DEC-13 05-DEC-1 3 05-DEC-1 3 05-DEC-13 05-DEC-1 3 05-DEC-1 3 05-DEC-1 3 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 Nuclide Concentration (pCi/Liter)
Duplicate Analysis ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM) 3.273 +/-
2.568+/-
3.7 2.5 4.1 3.3 2.6 0.691 0.339 2.0 1.4 2.8 2.2 1.7 2.5 3.4 3.3 2.7 0.667 0.456 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-52
Exposure Pathway - Waterborne Drinking Water Location 1O-DW Collection Date Nuclide Concentration (pCilLiter)
Duplicate Analysis 05-FEB-13 05-FEB-1 3 05-FEB-1 3 05-FEB-13 05-FEB-13 05-FEB-1 3 05-FEB-1 3 05-FEB-13 05-FEB-13 05-FEB-1 3 05-FEB-1 3 05-MAR-13 05-MAR-13 05-MAR-1 3 05-MAR-1 3 05-MAR-13 05-MAR-13 05-MAR-13 05-MAR-1 3 05-MAR-13 05-MAR-13 05-MAR-1 3 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 01-APR-13 06-MAY-1 3 06-MAY-13 06-MAY-13 06-MAY-13 06-MAY-13 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-1 37 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 2.680 +/-
3.6 2.8 3.7 3.1 6.1 2.5 2.7 2.8 2.4 0.502 0.458 4.1
< 4.6
< 6.1
< 4.8 2.602 +/-
2.378+/-
4.9 3.6 2.6 4.7 4.1 0.707 0.3 3.0 1.9 4.9 2.7 4.3 2.0 2.7 2.6 2.0 0.501 0.316 2.0 2.7 4.2 1.6 3.9 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-53
Exposure Pathway - Waterborne Drinking Water Location 1O-DW Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 06-MAY-13 06-MAY-1 3 06-MAY-1 3 06-MAY-13 06-MAY-13 06-MAY-1 3 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 01-JUL-13 05-AUG-13 05-AUG-13 05-AUG-13 05-AUG-13 05-AUG-13 05-AUG-13 05-AUG-1 3 05-AUG-13 05-AUG-13 05-AUG-13 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 2.026+/-
3.0 2.6 2.8 2.1 0.66 0.31
< 3.6
< 2.0
< 5.3
< 2.2
< 3.6
< 3.6
< 3.2
< 2.3 3.007 +/-
2.101 +/-
2.903 +/-
4.3 0.696 0.312 2.2 2.4 1.8 2.2 2.8 2.7 2.5 2.8 3.1 0.667 0.29 2.0 3.2 6.3 3.5 3.8 2.4 2.7 3.9 3.9 0.674 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-54
Exposure Pathway - Waterborne Drinking Water Location IO-DW Collection Date Nuclide Concentration (pCi/Liter)
Duplicate Analysis 05-AUG-1 3 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-1 3 03-SEP-13 03-SEP-13 03-SEP-1 3 07-OCT-1 3 07-OCT-13 07-OCT-1 3 07-OCT-1 3 07-OCT-1 3 07-OCT-13 07-OCT-13 07-OCT-1 3 07-OCT-13 07-OCT-13 07-OCT-1 3 04-NOV-1 3 04-NOV-1 3 04-NOV-13 04-NOV-13 04-NOV-1 3 04-NOV-1 3 04-NOV-13 04-NOV-1 3 04-NOV-1 3 04-NOV-13 04-NOV-13 05-DEC-1 3 05-DEC-13 05-DEC-13 05-DEC-13 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
< 0.334
< 3.4
< 3.1
< 8.5
< 3.1
< 3.9
< 2.9
< 4.4 3.471 +/-
3.316 +/-
3.703 +/-
4.5 2.4 0.76 0.272 3.3 2.6 5.6 3.5 4.9 3.2 2.7 2.5 3.2 0.703 0.259 2.5 1.0 3.7 2.4 3.0 1.8 2.5 3.1 2.5 0.567 0.279 3.6 2.8 3.5 3.7 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-55
Exposure Pathway - Waterborne Drinking Water Location 1O-DW Collection Date Nuclide Concentration (pCilLiter)
Duplicate Analysis 05-DEC-13 05-DEC-1 3 05-DEC-1 3 05-DEC-13 05-DEC-13 05-DEC-1 3 05-DEC-1 3 07-JAN-14 07-JAN-14 07-JAN-1 4 07-JAN-1 4 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 07-JAN-14 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM)
MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 CS-134 CS-137 BA-LA-140 GROSS BETA 1-131 (CHEM) 3.996 +/-
3.6 2.7 3.5 3.6 3.0 0.78 0.334 3.4 2.0
< 4.1
< 3.1
< 6.0
< 3.0
< 4.0 2.979 +/-
3.5 2.9 0.704
< 0.283 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-56
Exposure Pathway - Waterborne Drinking Water Quarterly Tritium Analysis Location BW-15 Collection Date 01-APR-13 01-JUL-13 07-OCT-13 07-JAN-1 4 Nuclide Concentration (pCi/Liter)
Duplicate Analysis H-3 H-3 H-3 H-3
< 150
< 151
< 151
< 149 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-57
Exposure Pathway - Waterborne Drinking Water Quarterly Tritium Analysis Location IO-DW Collection Date 01-APR-13 01-JUL-13 07-OCT-1 3 07-JAN-14 Nuclide H-3 H-3 H-3 H-3 Concentration (pCi/Liter)
Duplicate Analysis
< 150
< 151
< 151
< 149 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-58
Exposure Pathway - Waterborne Shoreline Sediment Location DC Collection Date 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-1 3 06-JUN-13 06-JUN-13 03-DEC-1 3 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-13 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 7,355.9 +/-
6,367.6+1 498.8 24.4 24.7 40.4 9.8 39.6 16.5 19.3 442.0 13.2 15.0 40.4 12.2 38.9 15.8 17.7 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 59
Exposure Pathway - Waterborne Shoreline Sediment Location EEA Collection Date 30-APR-13 30-APR-13 30-APR-13 30-APR-13 30-APR-13 30-APR-1 3 30-APR-1 3 30-APR-13 03-SEP-1 3 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-1 3 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-1 3 03-SEP-1 3 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-1 3 03-SEP-13 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 K-40 K-40 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 CS-134 CS-134 CS-1 37 CS-137 11,221.0 +/-
701.1 23.4 22.1 S<
28.6 19.4 40.4 21.2 24.4 12,353.0 +/-
778.9 11,893.0 +1-681.3 28.0 24.4 42.8 22.1 78.8 103.8 21.2 9.6 46.4 65.6 21.5 19.6 97.8 +/-
34.6 89.2 +/-
41.6 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-60
Exposure Pathway - Waterborne Shoreline Sediment Location JRR Collection Date 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 Nuclide K-40 K-40 MN-54 MN-54 CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 CS-1 34 CS-134 CS-137 CS-1 37 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 Concentration (pCilKg Dry) 12,349.0 13,061.0
+1-
+1-663.0 712.2 23.8 27.6 23.6 29.0 59.3 59.4 26.2 18.9 58.0 57.4 17.6 Duplicate Analysis Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 10,926.0 +/-
19.2 25.0 23.9 595.2 23.3 28.2 69.7 10.9 45.0 19.0 23.5 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 61
Exposure Pathway - Ingestion Fish Location CCL Collection Date 21-MAY-13 21-MAY-13 21 -MAY-1 3 21 -MAY-1 3 21-MAY-13 21-MAY-13 21 -MAY-1 3 21-MAY-1 3 21 -MAY-1 3 21-MAY-13 21-MAY-13 21-MAY-1 3 21 -MAY-1 3 21-MAY-13 21-MAY-13 21-MAY-13 21 -MAY-1 3 21 -MAY-1 3 21-MAY-13 21-MAY-13 21-MAY-13 21 -MAY-1 3 21-MAY-1 3 21-MAY-13 21-MAY-13 21-MAY-13 21-MAY-13 21-MAY-1 3 21-MAY-13 21-MAY-13 21-MAY-13 21 -MAY-1 3 21-MAY-13 21-MAY-1 3 21-MAY-13 21-MAY-13 21-MAY-13 21-MAY-13 21 -MAY-13 Sample Nuclide Description CHANNEL CATFISH K-40 CHANNEL CATFISH MN-54 CHANNEL CATFISH CO-58 CHANNEL CATFISH FE-59 CHANNEL CATFISH CO-60 CHANNEL CATFISH ZN-65 CHANNEL CATFISH 1-131 CHANNEL CATFISH CS-1 34 CHANNEL CATFISH CS-137 CHANNEL CATFISH H-3 COMMON CARP K-40 COMMON CARP MN-54 COMMON CARP CO-58 COMMON CARP FE-59 COMMON CARP CO-60 COMMON CARP ZN-65 COMMON CARP 1-131 COMMON CARP CS-134 COMMON CARP CS-137 COMMON CARP H-3 SMALLMOUTH BASS K-40 SMALLMOUTH BASS MN-54 SMALLMOUTH BASS CO-58 SMALLMOUTH BASS FE-59 SMALLMOUTH BASS CO-60 SMALLMOUTH BASS ZN-65 SMALLMOUTH BASS 1-131 SMALLMOUTH BASS CS-134 SMALLMOUTH BASS CS-1 37 SMALLMOUTH BASS H-3 SMALLMOUTH BUFFALO K-40 SMALLMOUTH BUFFALO MN-54 SMALLMOUTH BUFFALO CO-58 SMALLMOUTH BUFFALO FE-59 SMALLMOUTH BUFFALO CO-60 SMALLMOUTH BUFFALO ZN-65 SMALLMOUTH BUFFALO 1-131 SMALLMOUTH BUFFALO CS-134 SMALLMOUTH BUFFALO CS-137 Concentration (pCi/Kg Wet)
Duplicate Analysis 3,689.8 +/-
8,852.0 +/-
3,604.5 +1-8,158.0 +1-3,188.4 +/-
8,140.0 +1-3,000.9 +/-
421.3 13.7 8.2 16.8 6.1 27.5 13.3 11.0 7.4 242.0 402.7 12.7 7.1 28.2 4.8 16.4 24.8 10.6 10.0 229.0 364.2 10.8 4.7 17.7 4.4 20.2 12.6 7.2 12.4 233.0 359.9 12.2 6.6 27.9 6.9 17.7 13.4 12.6 11.0 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-62
Exposure Pathway - Ingestion Fish Location CCL Collection Date 21 -MAY-1 3 17-OCT-1 3 17-OCT-13 17-OCT-1 3 17-OCT-1 3 17-OCT-1 3 17-OCT-13 17-OCT-13 17-OCT-1 3 17-OCT-1 3 17-OCT-13 17-OCT-1 3 17-OCT-1 3 17-OCT-13 17-OCT-1 3 17-OCT-13 17-OCT-1 3 17-OCT-13 17-OCT-13 17-OCT-1 3 17-OCT-1 3 17-OCT-13 17-OCT-1 3 17-OCT-1 3 17-OCT-1 3 17-OCT-13 17-OCT-13 17-OCT-1 3 17-OCT-13 17-OCT-13 17-OCT-13 17-OCT-1 3 17-OCT-13 17-OCT-13 17-OCT-13 17-OCT-1 3 17-OCT-13 17-OCT-13 17-OCT-1 3 Sample Nuclide Description SMALLMOUTH BUFFALO H-3 BLUE CATFISH K-40 BLUE CATFISH MN-54 BLUE CATFISH CO-58 BLUE CATFISH FE-59 BLUE CATFISH CO-60 BLUE CATFISH ZN-65 BLUE CATFISH 1-131 BLUE CATFISH CS-134 BLUE CATFISH CS-1 37 BLUE CATFISH H-3
-CHANNEL CATFISH K-40 CHANNEL CATFISH MN-54 CHANNEL CATFISH CO-58 CHANNEL CATFISH FE-59 CHANNEL CATFISH CO-60 CHANNEL CATFISH ZN-65 CHANNEL CATFISH 1-131 CHANNEL CATFISH CS-1 34 CHANNEL CATFISH CS-137 CHANNEL CATFISH H-3 COMMON CARP K-40 COMMON CARP MN-54 COMMON CARP CO-58 COMMON CARP FE-59 COMMON CARP CO-60 COMMON CARP ZN-65 COMMON CARP 1-131 COMMON CARP CS-134 COMMON CARP CS-1 37 COMMON CARP H-3 SMALLMOUTH BUFFALO K-40 SMALLMOUTH BUFFALO MN-54 SMALLMOUTH BUFFALO CO-58 SMALLMOUTH BUFFALO FE-59 SMALLMOUTH BUFFALO CO-60 SMALLMOUTH BUFFALO ZN-65 SMALLMOUTH BUFFALO 1-131 SMALLMOUTH BUFFALO CS-134 Concentration (pCiIKg Wet)
Duplicate Analysis 8,022.0 +/-
2,697.7 +/-
7,004.0 +1-2,984.0 +/-
8,007.0 +/-
2,799.4 +1-7,348.0 +1-2,840.3 +/-
223.0 304.7 15.6 9.2 25.7 4.5 12.6 47.5 11.9 12.4 228.0 360.9 12.6 14.5 22.6 3.4 26.3 46.6 12.2 10.6 242.0 346.7 13.3 8.1 42.1 8.7 27.7 58.0 12.8 17.1 223.0 353.8 12.8 9.9 32.0 10.8 32.2 71.2 13.9 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-63
Exposure Pathway - Ingestion Fish Location CCL Collection Date 17-OCT-13 17-OCT-1 3 17-OCT-1 3 17-OCT-13 17-OCT-13 17-OCT-1 3 17-OCT-13 17-OCT-13 17-OCT-1 3 17-OCT-1 3 17-OCT-13 17-OCT-13 17-OCT-13 17-OCT-1 3 17-OCT-13 17-OCT-13 17-OCT-13 17-OCT-1 3 17-OCT-1 3 17-OCT-13 17-OCT-1 3 17-OCT-1 3 Sample Nuclide Description SMALLMOUTH BUFFALO CS-137 SMALLMOUTH BUFFALO H-3 WALLEYE K-40 WALLEYE MN-54 WALLEYE CO-58 WALLEYE FE-59 WALLEYE CO-60 WALLEYE ZN-65 WALLEYE 1-131 WALLEYE CS-1 34 WALLEYE CS-137 WALLEYE H-3 WHITE BASS K-40 WHITE BASS MN-54 WHITE BASS CO-58 WHITE BASS FE-59 WHITE BASS CO-60 WHITE BASS ZN-65 WHITE BASS 1-131 WHITE BASS CS-134 WHITE BASS CS-1 37 WHITE BASS H-3 Concentration (pCi/Kg Wet)
Duplicate Analysis 6,985.0 +/-
3,391.0 +/-
7,414.0 +1-3,095.1 +1-7,496.0 +/-
12.4 220.0 315.5 8.9 12.0 27.0 11.2 14.5 41.0 12.7 12.1 228.0 312.8 9.9 11.5 28.7 9.0 25.8 78.3 13.1 13.2 227.0 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-64
Exposure Pathway - Ingestion Fish Location JRR Collection Date 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-13 03-DEC-13 Sample Nuclide Description CHANNEL CATFISH K-40 CHANNEL CATFISH MN-54 CHANNEL CATFISH CO-58 CHANNEL CATFISH FE-59 CHANNEL CATFISH CO-60 CHANNEL CATFISH ZN-65 CHANNEL CATFISH 1-131 CHANNEL CATFISH CS-1 34 CHANNEL CATFISH CS-137 CHANNEL CATFISH H-3 COMMON CARP K-40 COMMON CARP MN-54 COMMON CARP CO-58 COMMON CARP FE-59 COMMON CARP CO-60 COMMON CARP ZN-65 COMMON CARP 1-131 COMMON CARP CS-1 34 COMMON CARP CS-1 37 COMMON CARP H-3 SMALLMOUTH BUFFALO K-40 SMALLMOUTH BUFFALO MN-54 SMALLMOUTH BUFFALO CO-58 SMALLMOUTH BUFFALO FE-59 SMALLMOUTH BUFFALO CO-60 SMALLMOUTH BUFFALO ZN-65 SMALLMOUTH BUFFALO 1-131 SMALLMOUTH BUFFALO CS-134 SMALLMOUTH BUFFALO CS-137 SMALLMOUTH BUFFALO H-3 CHANNEL CATFISH K-40 CHANNEL CATFISH MN-54 CHANNEL CATFISH CO-58 CHANNEL CATFISH FE-59 CHANNEL CATFISH CO-60 CHANNEL CATFISH ZN-65 CHANNEL CATFISH 1-131 CHANNEL CATFISH CS-134 CHANNEL CATFISH CS-137 Concentration (pCi/Kg Wet)
Duplicate Analysis 3,669.4 +/-
3,660.4 +/-
3,661.9 +/-
3,334.1 +/-
376.5 11.1 10.4 20.8 8.0 29.1 27.4 13.6 13.1 156.0 415.6 16.1 9.2 27.7 10.2 25.0 27.1 14.8 14.0 156.0 378.2 10.1 11.8 25.9 10.6 22.1 19.2 14.0 12.7 156.0 375.3 8.9 10.2 15.4 4.3 10.4 27.5 16.0 7.3 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-65
Exposure Pathway - Ingestion Fish Location JRR Collection Date 03-DEC-13 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 Sample Description CHANNEL CATFISH COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP COMMON CARP FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM FRESHWATER DRUM Nuclide H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 1-131 CS-134 CS-1 37 H-3 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 1-131 CS-134 CS-137 H-3 Concentration (pCi/Kg Wet)
Duplicate Analysis 2,990.1 +/-
3,i79.5 +/-
113.0 364.1 12.3 8.3 32.2 11.1 27.3 26.1 14.9 12.3 118.0 299.7 11.4 6.3 24.2 6.4 26.0 19.1 11.2 14.5 122.0 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-66
Exposure Pathway - Ingestion Food/Garden Location B-1 Collection Date 28-MAY-1 3 28-MAY-1 3 28-MAY-13 28-MAY-13 28-MAY-1 3 28-MAY-1 3 28-MAY-1 3 28-MAY-13 28-MAY-13 28-MAY-13 28-MAY-1 3 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 Sample Description Nuclide Concentration (pCi/Kg Wet)
Duplicate Analysis HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 BE-7 BE-7 K-40 K-40 MN-54 MN-54 362.5 5,075.4 831.1 5,710.0 1,107.5 5,193.3 325.1 470.5 4,907.4 4,891.9
+/-
101.6
+/-
337.9 11.0 10.5 22.0 12.6 25.0 8.1 21.1 11.0 10.3
+/-
157.6
+/-
418.8 11.4 9.0 13.4 10.4 28.2 11.2 22.7 9.9 10.8
+/-
254.4
+/-
391.2 9.9 10.9 25.5 7.2 33.9 11.5 19.3 9.9 9.8
+/-
104.1
+/-
159.6
+/-
350.4
+/-
407.9 11.5 6.8 Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-67
Exposure Pathway - Ingestion Food/Garden Location B-1 Collection Date 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-1 3 17-SEP-13 17-SEP-13 14-OCT-13 14-OCT-13 14-OCT-13 14-OCT-1 3 14-OCT-1 3 14-OCT-1 3 14-OCT-13 14-OCT-13 14-OCT-13 14-OCT-1 3 14-OCT-1 3 Sample Description Nuclide Concentration (pCiIKg Wet)
HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES CO-58 CO-58 FE-59 FE-59 CO-60 CO-60 ZN-65 ZN-65 ZR-NB-95 ZR-NB-95 1-131 1-131 CS-134 CS-134 CS-137 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 281.4 5,745.2 623.5 4,688.5
+1-
+1-
+1-
+1-9.1 14.6 14.3 23.1 6.7 12.1 27.0 21.5 17.0 9.3 21.5 17.8 9.5 11.4 7.9 11.0 147.4 408.3 11.4 12.9 19.3 14.3 26.3 13.6 28.1 9.6 12.5 177.2 395.8 8.2 8.7 19.3 9.3 20.6 10.1 35.1 13.7 13.8 Duplicate Analysis Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 68
Exposure Pathway - Ingestion Food/Garden Location D-2 Collection Date 28-MAY-13 28-MAY-1 3 28-MAY-1 3 28-MAY-13 28-MAY-13 28-MAY-1 3 28-MAY-1 3 28-MAY-13 28-MAY-13 28-MAY-1 3 28-MAY-1 3 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 19-AUG-13 19-AUG-13 19-AUG-1 3 19-AUG-13 19-AUG-13 19-AUG-13 Sample Description Nuclide Concentration (pCi/Kg Wet)
Duplicate Analysis HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 411.8 5,011.0 802.9 6,803.9 1,259.3 5,725.8 908.3 4,718.7
+/-
132.9
+/-
344.2 10.2 10.9 13.4 9.3 22.8 8.7 24.5 12.2 10.6
+1-206.8
+/-
530.0 13.7 12.3 29.8 15.8 44.3 17.8 31.0 13.3 18.0
+/1-189.9
+/-
410.5 12.5 6.0 18.0 12.3 12.3 16.4 29.9 12.1 14.9
+/-
164.6
+/-
409.4 12.7 11.9 34.4 10.0 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-69
Exposure Pathway - Ingestion FoodlGarden Location D-2 Collection Date 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 17-SEP-13 17-SEP-13 17-SEP-1 3 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-1 3 17-SEP-1 3 17-SEP-13 17-SEP-13 14-OCT-1 3 14-OCT-1 3 14-OCT-1 3 14-OCT-13 14-OCT-13 14-OCT-1 3 14-OCT-1 3 14-OCT-1 3 14-OCT-13 14-OCT-13 14-OCT-1 3 Sample Description HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES Nuclide ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-1 37 Concentration (pCi/Kg Wet)
Duplicate Analysis 396.7+/
6,644.2 +/-
6,321.7+-
24.7 15.1 20.4 10.6 12.8 143.3 455.4 10.0 15.2 34.6 8.2 22.2 8.8 22.8 11.3 13.8 214.6 531.2 18.2 14.8 33.7 15.9 23.3 17.1 39.2 20.0 18.0 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 70
Exposure Pathway - Ingestion Food/Garden Location H-2 Collection Date 28-MAY-1 3 28-MAY-1 3 28-MAY-1 3 28-MAY-1 3 28-MAY-1 3 28-MAY-1 3 28-MAY-13 28-MAY-1 3 28-MAY-1 3 28-MAY-13 28-MAY-1 3 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-1 3 19-AUG-13 19-AUG-13 19-AUG-1 3 19-AUG-13 19-AUG-13 19-AUG-13 19-AUG-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-1 3 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-13 17-SEP-13 14-OCT-1 3 14-OCT-1 3 14-OCT-13 14-OCT-13 14-OCT-1 3 14-OCT-1 3 Sample Description Nuclide Concentration (pCi/Kg Wet)
Duplicate Analysis HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 323.1 +/-
5,285.6 +1-763.8+1 5,157.1+1 5,201.6+1 399.7+1 6,914.9+1 120.6 375.2 10.5 13.5 17.5 11.5 23.4 13.1 24.2 9.3 11.8 141.9 374.3 8.7 7.9 15.7 8.9 26.3 14.0 17.1 6.7 7.2 131.1 400.6 9.4 10.5 24.1 8.5 24.4 9.8 29.7 12.1 7.7 205.1 536.5 17.0 17.5 24.0 14.9 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 71
Exposure Pathway - Ingestion FoodlGarden Location H-2 Collection Date 14-OCT-1 3 14-OCT-1 3 14-OCT-1 3 14-OCT-1 3 14-OCT-13 Sample Description Nuclide Concentration (pCilKg Wet)
Duplicate Analysis HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES HORSERADISH LEAVES ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 28.9 18.6 35.1 16.0 10.7 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-72
Exposure Pathway - Ingestion FoodlGarden Location Q-6 Collection Date 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 24-JUN-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 22-JUL-13 Sample Description Nuclide Concentration (pCi/Kg Wet)
Duplicate Analysis WATERMELON LEAVES WATERMELON LEAVES WATERMELON LEAVES WATERMELON LEAVES WATERMELON LEAVES WATERMELON LEAVES WATERMELON LEAVES WATERMELON LEAVES WATERMELON LEAVES WATERMELON LEAVES WATERMELON LEAVES SQUASH LEAVES SQUASH LEAVES SQUASH LEAVES SQUASH LEAVES SQUASH LEAVES SQUASH LEAVES SQUASH LEAVES SQUASH LEAVES SQUASH LEAVES SQUASH LEAVES SQUASH LEAVES BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 371.6 5,584.6 1,690.7 4,698.5
+1-
+1-
+1-
+1-138.4 454.8 13.2 13.3 15.9 12.3 23.3 16.0 25.2 13.0 13.1 208.8 357.2 10.1 12.6 16.3 10.0 14.4 10.4 28.0 10.4 11.8 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-73
Exposure Pathway - Ingestion Feed and Forage Location NR-D1 Collection Date 29-OCT-13 29-OCT-1 3 29-OCT-1 3 29-OCT-13 29-OCT-13 29-OCT-13 29-OCT-1 3 29-OCT-13 29-OCT-13 29-OCT-13 29-OCT-13 Sample Description NON-IRRIGATED SOYBEANS NON-IRRIGATED SOYBEANS NON-IRRIGATED SOYBEANS NON-IRRIGATED SOYBEANS NON-IRRIGATED SOYBEANS NON-IRRIGATED SOYBEANS NON-IRRIGATED SOYBEANS NON-IRRIGATED SOYBEANS NON-IRRIGATED SOYBEANS NON-IRRIGATED SOYBEANS NON-IRRIGATED SOYBEANS Nuclide BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 Concentration (pCi/Kg Wet) 65.4 16,342.0 +/-
514.3 8.8 11.8 27.9 9.0 14.0 5.5 11.4 10.2 6.1 Duplicate Analysis 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-74
Exposure Pathway - Ingestion Feed and Forage Location NR-D2 Collection Date 14-OCT-1 3 14-OCT-13 14-OCT-13 14-OCT-1 3 14-OCT-1 3 14-OCT-13 14-OCT-13 14-OCT-13 14-OCT-1 3 14-OCT-1 3 14-OCT-13 Sample Description Nuclide Concentration (pCi/Kg Wet)
Duplicate Analysis IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS IRRIGATED SOYBEANS BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 12,882.0 +/-
60.2 496.4 5.1 5.6 18.6 9.2 28.7 11.8 16.3 11.2 7.3 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-75
Exposure Pathway - Ingestion Feed and Forage Location NR-U1 Collection Date 10-OCT-13 10-OCT-1 3 10-OCT-1 3 10-OCT-13 10-OCT-13 10-OCT-1 3 10-OCT-1 3 10-OCT-1 3 10-OCT-13 10-OCT-1 3 10-OCT-1 3 04-NOV-13 04-NOV-13 04-NOV-13 04-NOV-13 04-NOV-13 04-NOV-1 3 04-NOV-1 3 04-NOV-13 04-NOV-13 04-NOV-1 3 04-NOV-13 04-NOV-13 04-NOV-13 04-NOV-13 04-NOV-1 3 04-NOV-1 3 04-NOV-1 3 04-NOV-13 04-NOV-13 04-NOV-13 04-NOV-1 3 04-NOV-13 Sample Description Nuclide Concentration (pCi/Kg Wet)
Duplicate Analysis IRRIGATED CORN BE-7 IRRIGATED CORN K-40 IRRIGATED CORN MN-54 IRRIGATED CORN CO-58 IRRIGATED CORN FE-59 IRRIGATED CORN CO-60 IRRIGATED CORN ZN-65 IRRIGATED CORN ZR-NB-95 IRRIGATED CORN 1-131 IRRIGATED CORN CS-134 IRRIGATED CORN CS-1 37 NON-IRRIGATED SOYBEANS BE-7 NON-IRRIGATED SOYBEANS BE-7 NON-IRRIGATED SOYBEANS K-40 NON-IRRIGATED SOYBEANS K-40 NON-IRRIGATED SOYBEANS MN-54 NON-IRRIGATED SOYBEANS MN-54 NON-IRRIGATED SOYBEANS CO-58 NON-IRRIGATED SOYBEANS CO-58 NON-IRRIGATED SOYBEANS FE-59 NON-IRRIGATED SOYBEANS FE-59 NON-IRRIGATED SOYBEANS CO-60 NON-IRRIGATED SOYBEANS CO-60 NON-IRRIGATED SOYBEANS ZN-65 NON-IRRIGATED SOYBEANS ZN-65 NON-IRRIGATED SOYBEANS ZR-NB-95 NON-IRRIGATED SOYBEANS ZR-NB-95 NON-IRRIGATED SOYBEANS 1-131 NON-IRRIGATED SOYBEANS 1-131 NON-IRRIGATED SOYBEANS CS-134 NON-IRRIGATED SOYBEANS CS-134 NON-IRRIGATED SOYBEANS CS-137 NON-IRRIGATED SOYBEANS CS-137 57.4 2,543.7 +/-
201.9 4.8 3.9 12.7 5.4 18.9 9.9 17.2 6.3 4.7 66.9 57.1 13,299.0 +/-
474.3 12,669.0 +/-
487.5 8.6 6.6 9.7 7.8 25.6 15.4 11.3 4.9 33.3 11.8 11.1 6.1 14.0 8.0 10.0 10.3 6.3 10.5 Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate Duplicate 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 76
Exposure Pathway - Aquatic Bottom Sediment Location DC Collection Date 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 03-DEC-13 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 FE-55 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 FE-55 Concentration (pCi/Kg Dry)
Duplicate Analysis 11,336.0 +/-
97.4+-
9,402.3+1 89.5+1 1,043.0 48.2 61.0 94.5 33.7 86.8 35.0 40.6 15,032.4 944.4 39.0 52.2 51.0 29.2 67.0 39.9 52.9 15,670.0 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 77
Exposure Pathway - Aquatic Bottom Sediment Location EEA Collection Date 30-APR-1 3 30-APR-1 3 30-APR-13 30-APR-1 3 30-APR-1 3 30-APR-1 3 30-APR-13 30-APR-13 26-AUG-13 26-AUG-13 26-AUG-1 3 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 26-AUG-13 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-i 34 CS-1 37 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 11,576.0 +/-
574.2 19.3 17.9 47.1 12.3 51.9 19.1 55.8 +/-
15.7 11,346.0 +/-
669.6 26.0 26.9 68.3 12.2 54.7 23.6 67.0 +/-
29.5 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-78
Exposure Pathway - Aquatic Bottom Sediment Location ESW 2013-5 Collection Date 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-1 37 FE-55 9,303.1 +/-
901.4 45.9 73.0 125.7 36.4 108.5 37.7 47.7 14,371.1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-79
Exposure Pathway - Aquatic Bottom Sediment Location ESW 2013-6 Collection Date 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-137 FE-55 5,110.1 +/-
683.3 26.7 30.4 64.1 10.5 66.1 30.6 32.7 16,091.5 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-80
Exposure Pathway - Aquatic Bottom Sediment Location JRR Collection Date 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 11-JUN-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-137 12,752.0 +/-
1,135.0 57.2 29.9 121.9 27.3 94.4 39.6 54.8 11,660.0 +/-
993.4 38.1 54.4 134.2 13.3 99.4 33.0 84.8 +/-
43.3 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 81
Exposure Pathway - Aquatic Bottom Sediment Location MUDS Collection Date 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-1 37 10,357.0 +/-
645.8 22.2 23.1 106.0 9.8 58.7 21.7
+/-
22.6 38.4 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 82
Exposure Pathway - Aquatic Bottom Sediment Location UHS 2013-17 Collection Date 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 Nuclide Concentration (pCilKg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 FE-55 12,602.0 +/-
690.7 34.6 43.8 75.2 22.1 78.0 20.5
+/-
27.9 11,670.2 65.8 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-83
Exposure Pathway - Aquatic Bottom Sediment Location UHS 2013-18 Collection Date 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 Nuclide Concentration (pCilKg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 FE-55 9,387.0
+/-
822.3 39.2 47.8 116.9 33.8 80.6 24.4
+/-
31.4 14,371.1 55.7 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 84
Exposure Pathway - Aquatic Bottom Sediment Location UHS 2013-19 Collection Date 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-1 34 CS-137 FE-55 9,395.4 +/-
937.7 45.2 46.7 100.2 26.1 69.6 31.1
+/-
39.2 14,371.1 103.3 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-85
Exposure Pathway - Aquatic Bottom Sediment Location UHS 2013-20 Collection Date 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 FE-55 10,289.0 +/-
692.4 32.9 41.7 112.5 12.8 80.8 20.6 26.8 14,371.1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 86
Exposure Pathway - Aquatic Bottom Sediment Location UHS 2013-21 Collection Date 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 FE-55 9,508.7 +/-
749.2 32.7 40.0 75.8 24.2 48.0 26.2
+/-
22.0 15,538.2 58.1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 87
Exposure Pathway - Aquatic Bottom Sediment Location UHS 2013-22 Collection Date 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 03-DEC-13 Nuclide Concentration (pCilKg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 FE-55 11,707.0 +/-
820.3 29.6 34.9 56.8 29.2 87.4 27.3 64.5 +/-
29.2 15,918.5 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-88
Exposure Pathway - Aquatic Bottom Sediment Location UHS 2013-23 Collection Date 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 Nuclide Concentration (pCilKg Dry)
Duplicate Analysis K-40 8,718.5 +/-
782.4 MN-54 24.6 CO-58 32.8 FE-59 72.7 CO-60 21.1 ZN-65 67.2 CS-134 29.0 CS-1 37 34.4 FE-55 15,778.3 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-89
Exposure Pathway - Aquatic Bottom Sediment Location UHS 2013-24 Collection Date 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 FE-55 Concentration (pCi/Kg Dry)
Duplicate Analysis 11,811.0 +/-
1,010.0 54.7 52.7 101.3 46.8 94.3 47.4 62.9 15,876.2 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-90
Exposure Pathway - Aquatic Bottom Sediment Location UHS HS-5 Collection Date 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 06-JUN-13 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 FE-55 9,468.8 +/-
864.3 47.6 34.1 133.5 16.5 99.8 28.9 62.7 +/-
33.7 14,942.8 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C - 91
Exposure Pathway - Aquatic Bottom Sediment Location UHS HS-6 Collection Date 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-13 03-DEC-13 03-DEC-1 3 03-DEC-1 3 03-DEC-1 3 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 FE-55 10,688.0 +/-
963.5 51.6 44.9 108.8 16.3 102.9 40.0
+/-
42.5
< 15,915.3 108.2 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-92
Exposure Pathway - Aquatic Vegetation Location DC-ALT Collection Date 01-AUG-13 01-AUG-13 01-AUG-13 01-AUG-13 01-AUG-13 01-AUG-13 01-AUG-13 01-AUG-13 01-AUG-13 01-AUG-13 01-AUG-13 Sample Description AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS AMERICAN LOTUS Nuclide BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 Concentration (pCi/Kg Wet)
Duplicate Sample 1,872.6 2,282.7
+/-
+/-
269.9 388.3 19.3 20.5 21.6 15.5 36.9 27.3 40.4 15.5 18.5 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -
93
Exposure Pathway - Aquatic Vegetation Location EEA Collection Date Sample Description Nuclide Concentration (pCi/Kg Wet)
Duplicate Sample 03-SEP-1 3 03-SEP-13 03-SEP-1 3 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-13 03-SEP-13 ARROWHEAD ARROWHEAD ARROWHEAD ARROWHEAD ARROWHEAD ARROWHEAD ARROWHEAD ARROWHEAD ARROWHEAD ARROWHEAD ARROWHEAD BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 4,998.3 +/-
146.7 424.1 13.3 16.0 15.8 17.3 21.8 13.6 22.5 14.5 9.8 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-94
Exposure Pathway - Aquatic Vegetation Location MUDS Collection Date Sample Description Nuclide Concentration (pCi/Kg Wet)
Duplicate Sample 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-13 16-SEP-1 3 16-SEP-13 AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED AMERICAN PONDWEED BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-1 37 299.4 1,861.0
+1-
+1-67.4 164.7 6.1 4.7 4.6 5.2 9.2 4.9 12.8 5.3 6.7 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -
95
Exposure Pathway - Terrestrial Vegetation Location EEA Collection Date 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 Sample Description PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE Nuclide Concentration (pCi/Kg Wet)
Duplicate Analysis BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-134 CS-137 1,017.9+/-
200.4 7,466.5 +/-
475.6 14.0 15.0 26.1 12.5 32.4 16.6 33.2 11.9 14.4 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -
96
Exposure Pathway - Terrestrial Vegetation Location MUDS Collection Date 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 03-JUN-13 Sample Description PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE PASTURAGE Nuclide BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-NB-95 1-131 CS-1 34 CS-137 Concentration (pCi/Kg Wet)
Duplicate Analysis 1,830.1 +/-
5,868.0 +/-
342.4 644.2 24.4 19.5 41.4 16.2 36.8 24.3 37.8 19.7 28.5 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C -
97
Exposure Pathway - Terrestrial Soil Location EEA Collection Date 23-JAN-13 23-JAN-1 3 23-JAN-13 23-JAN-1 3 23-JAN-13 23-JAN-1 3 23-JAN-1 3 23-JAN-13 28-OCT-13 28-OCT-1 3 28-OCT-1 3 28-OCT-13 28-OCT-13 28-OCT-1 3 28-OCT-13 28-OCT-13 Nuclide K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 Concentration (pCi/Kg Dry)
Duplicate Analysis 8,935.2 +/-
i73.8+-
10,747.0+-
249.6+-
626.4 28.5 37.6 113.7 17.5 58.3 26.0 29.5 678.9 25.5 20.5 36.1 25.8 45.0 26.9 40.4 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-98
Exposure Pathway - Terrestrial Soil Location MUDS Collection Date 23-JAN-13 23-JAN-13 23-JAN-13 23-JAN-1 3 23-JAN-1 3 23-JAN-13 23-JAN-13 23-JAN-1 3 Nuclide Concentration (pCi/Kg Dry)
Duplicate Analysis K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-137 11,641.0 +/-
718.7 34.0 31.5 104.2 9.8 60.2 25.2 148.3 +/-
39.1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-99
Exposure Pathway - Ingestion Meat Location R2.7 Collection Date 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 18-NOV-13 Sample Description Nuclide Concentration (pCi/Kg Wet)
Duplicate Analysis DEER DEER DEER DEER DEER DEER DEER DEER DEER K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 CS-134 CS-1 37 H-3 3,070.6 +/-
251.0 +/-
355.7 14.0 9.5 12.3 9.7 11.9 15.0 10.1 74.0 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page C-100
WOLF CREEK GENERATING STATION 2013 LAND USE CENSUS REPORT REVISION 1 Ad F
Prepared by:
Peer Review:
Teresa L. Rice Dan E. Haines 12-31-13 Date 1/7/14 Date 1/13/14 Date Approved by:
Robert A. Hammond 2013 Land Use Census Report, Revision 1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 1
EXECUTIVE
SUMMARY
The 2013 Land Use Census Report has been revised to incorporate the re-calculated D/Qs for the broadleaf vegetation locations using the data from Engineering Evaluation SA-1 3-002.
The annual Land Use Census of rural residents within five miles of the Wolf Creek Generating Station (WCGS) has been completed in 2013 in accordance with AP 07B-004, [Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program)].
No program changes are necessary regarding milk locations. Again, no milk sampling locations were identified.
The two broadleaf vegetation locations with the highest calculated annual average D/Q rankings are A2.60-17TE1527 and Q2.35-MILA1619.
AP 07B-004 specifies, "Alternate sampling locations may be used to provide continued monitoring". The third-ranked garden is N2.38-RODR9.
Since these gardens are currently listed as sample locations for the Radiological Environmental Monitoring Program in procedure AP 07B-004 (locations A-3, Q-6 and N-I), no program changes are necessary regarding broadleaf vegetation locations.
BACKGROUND Section 5.2, Attachment A, of procedure AP 07B-004, directs that "a Land Use Census shall be conducted annually during the growing season to identify the nearest (1) milk animal, (2) residence, and (3) garden of greater than 500 square feet producing broadleaf vegetation in each of the 16 meteorological sections within five miles of the WCGS site."
Table 5-1, Attachment A, of procedure AP 07B-004, requires that broadleaf vegetation samples be collected from "two indicator locations (using the criteria from the "Land Use Census" section) with highest calculated annual average D/Q."
Table 5-1, Attachment A, of procedure AP 07B-004, also requires that milk samples be collected from "three indicator locations within 5 miles of the site having the highest dose potential."
METHODOLOGY Over two hundred surveys were mailed to the rural residents living within five miles of WCGS.
A follow-up survey was sent to residents who did not respond.
The survey excluded the residents of New Strawn and Burlington.
These locations were excluded due to the large number of households and the low likelihood that information gained from these residences would affect the locations chosen for REMP sampling. Drive-by information was collected for the nearest residences in each sector that did not return surveys.
The information collected was compiled and the results are identified in Tables 1-3.
Calculations were performed so that garden locations could be ranked by their respective D/Q.
These results are contained in Table 4.
2013 Land Use Census Report, Revision 1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 2
RESULTS NOTE: A Global Positioning System was used to verify residence distances and sectors.
Two changes were noted for the nearest occupied residences in each sector. These changes occurred in sectors A and E.
Seven changes were noted for the nearest garden producing broadleaf vegetation.
These changes are identified in Table 3.
There were no changes regarding milk sample locations. Again, no locations were identified that routinely milked animals for human consumption.
It should be noted that since the last Land Use Census some of the address numbers were changed by the County. Addresses that were affected are identified by an asterisk on Table 2 and Table 3.
2013 Land Use Census Report, Revision 1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 3
TABLE I 2013 Land Use Census Data Location of Nearest:
Sector A
B C
D E
F G
H J
K L
M N
P Q
R Residence A2.47-17RD1474 B3.53-QURD1755 Cl.92-16RD1703 D2.03-QULA1571 E1.77-QULA1485 F1.84-QULA1419 G3.03-13RD1820 H3.09-12RD1711 J3.70-11 RD1540 K2.70-12LA1439 L2.10-NARD 1339 M2.34-14RD1 346 N2.08-15RD1350 P2.76-HW751534 Q2.35-MILA1619 R2.08-NALN 1650 Milkingq Animals None None None None None None None None None None None None None None None None Broadleaf Garden A2.60-17TEl 527 None C3.58-RERD1675 D3.00-16RD1829 None F2.44-RERD1391 G3.77-12RD1831 H3.89-1 1 RD1 655 J3.70-1 1RD1540 K4.10-NARD1120 L2.39-NARD1309 M3.78-LYRD1 390 N2.38-RODR9 P2.93-BRST250 Q2.35-MILA1619 None Identifiers are based upon the following protocol:
EXAMPLE: A2.47-17RD1474 "A" = Sector A "2.47" = 2.47 miles from the reactor "17RD1474" = address 2013 Land Use Census Report, Revision 1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D -4
TABLE 2 SECTOR 2012 NEAREST 2013 NEAREST RESIDENCE RESIDENCE A
A2.60-17TE1520 A2.47-17RD1474 B
B3.53-QURD1755 B3.53-QURD1755 C
Cl.92-16RD1655 Cl.92-16RD1703*
D D2.03-QULA1571 D2.03-QULA1571 E
EI.78-QULA1451 E1.77-QULA1485 F
F1.84-QULA1419 F1.84-QULA1419 G
G3.03-13RD1820 G3.03-13RD1820 H
H3.09-12RD1711 H3.09-12RD1711 J
J3.70-11RD1540 J3.70-11RD1540 K
K2.70-12LA1439 K2.70-12LA1439 L
L2.1 0-NARD1 339 L2.1 0-NARD1 339 M
M2.34-14RD1330 M2.34-14RD1346*
N N2.08-15RD1350 N2.08-15RD1350 P
P2.76-HW751534 P2.76-HW751534 Q
Q2.35-MILA1619 Q2.35-MILA1619 R
R2.08-NALN1650 R2.08-NALN1650 NOTE: Entries underlined indicate changes from the 2012 Land Use Census.
2013 Land Use Census Report, Revision 1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 5
TABLE 3 2013 Land Use Census Milk and Garden Data SECTOR 2012 2013 2012 NEAREST 2013 NEAREST MILKING MILKING GARDEN GARDEN ANIMALS ANIMALS PRODUCING PRODUCING BROADLEAF BROADLEAF VEGETATION VEGETATION A
None None A2.60-17TE1520 A2.60-17TE1527*
B None None None None C
None None C3.38-17RD1755 C3.58-RERD1675 D
None None D2.33-RERD1520 D3.00-16RD1829 E
None None None None F
None None F2.44-RERD1391 F2.44-RERD1391 G
None None None G3.77-12RD1831 H
None None H4.87-10RD1670 H3.89-11RD1655 J
None None J3.84-11RD1499 J3.70-11RD1540 K
None None K4.10-NARD1120 K4.10-NARD1120 L
None None L2.39-NARD1309 L2.39-NARD1309 M
None None M4.42-LYRD1231 M3.78-LYRD1390 N
None None N2.38-RODR9 N2.38-RODR9 P
None None P3.17-WDST425 P2.93-BRST250 Q
None None Q2.35-MILA1619 Q2.35-MILA1619 R
None None None None NOTE: Underlined entries indicate changes from the 2012 Land Use Census.
2013 Land Use Census Report, Revision 1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 6
TABLE 4 Information Used for DIQ Calculations FROM LAND USE FROM SA-13-002 DIST CALC NEAR NEAR FAR FAR SECTOR SECTOR (MI)
(METERS)
DIST D/Q DIST D/Q CALC RANKING A
2.60 4184 4000 1.86E-09 5000 1.26E-09 1.75E-09 1
B C
3.58 5761 5000 2.51E-10 6000 1.85E-10 2.01E-10 13 D
3.00 4828 4000 2.93E-10 5000 1.99E-10 2.15E-10 12 E
F 2.44 3927 3000 6.15E-10 4000 3.69E-10 3.87E-10 8
G 3.77 6067 6000 3.57E-10 7000 2.65E-10 3.51E-10 10 H
3.89 6260 6000 5.16E-10 7000 3.83E-10 4.81E-10 6
J 3.70 5955 5000 6.06E-10 6000 4.46E-10 4.53E-10 7
K 4.10 6598 6000 4.46E-10 7000.
3.31E-10 3.77E-10 9
L 2.39 3846 3000 1.1OE-09 4000 6.62E-10 7.29E-10 4
M 3.78 6083 6000 2.67E-10 7000 1.99E-10 2.61E-10 11 N
2.38 3830 3000 1.17E-09 4000 7.OOE-10 7.80E-10 3
P 2.93 4715 4000 7.64E-10 5000 5.19E-10 5.89E-10 5
Q 2.35 3782 3000 1.46E-09 4000 8.79E-10 1.01E-09 2
R Originated by:
Verified by:
Je?~~b Date:
12-31-13 Date:
1/7/14 2013 Land Use Census Report, Revision 1 2013 Annual Radiological Environmental Operating Report Wolf Creek Generating Station Page D - 7